Home
Moxa AWK-3121-M12-EU
Contents
1. 105 4 13 52 85 2 08 DIN Rail Mounting The aluminum DIN Rail attachment plate should be fixed to the back panel of the AWK 3121 when you take it out of the box If you need to reattach the DIN Rail attachment plate to the AWK 3121 make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 STEP 2 Insert the top of the DIN Rail into theThe DIN Rail attachment unit will slot just below the stiff metal spring snap into place as shown below metal spring metal spring To remove the AWK 3121 from the DIN Rail simply reverse Steps 1 and 2 Wall Mounting optional For some applications it may be more convenient to mount the AWK 3121 to a wall as illustrated below STEP 1 es a rat Remove the aluminum petites AS DIN Rail attachment plate 6 e top from the AWK 3121 and o o Plate then attach the wall mount plates with M3 screws as gt j i shown in the adjacent diagrams e e e bottom S A 7 e o plate 5 e lt au a aa STEP 2 6 0 mm Mounting the AWK 3121 to a wall requires 4 screws gt Use the AWK 3121 device with wall mount plates attached as a guide to mark the correct locations of the 4 screws The heads of the screws should be less 35 than 6 0 mm in diameter and the shafts should be less than 3 5 mm in diameter as shown in the figure at the right ie
2. is not being supplied from power input 1 On Power is being supplied from power PWR2 Green input z off Power is not being supplied from power input 2 On Power is being supplied via PoE PoF Amber off Power is not being supplied via PoE Blink Cannot get an IP address from the DHCP server interval 1 sec slow FAULT Red Blink IP address conflict interval 0 5 sec Off Error condition does not exist Green Software Ready Green Re Green The AWK has been located by AWK STATE d Blink Search Utility interval 1sec Red Booting error condition SIGNAL On Signal level 5 LEDs Green Off for Client mode only BRIDGE Green On AWK functions in Bridge Mode MODE Off AWK is not in Bridge Mode CLIENT Green On AWK functions in Client Mode MODE Off AWK is not in Client Mode On WLAN is in used Off WLAN is not in use TP Port LED Indicators Port Interface On TP port s 100Mbps link is active 100M Green Blink Data is being transmitted at 100 Mbps Off TP port s 100Mbps link is inactive On TP port s 10Mbps link is active 10M Yellow Blink Data is being transmitted at 10 Mbps Off TP port s 10Mbps link is inactive WLAN Amber 1i1 Specifications WLAN Interface Standards IEEE 802 11a b g for Wireless LAN IEEE 802 11i for Wireless Security IEEE 802 3 for 10BaseT IEEE 802 3u for 100BaseTX IEEE 802 3af for Pow
3. mm Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the wall and the screws NOTE Test the screw head and shank size by inserting the screw into one of the keyhole shaped apertures of the Wall Mounting Plates before it is screwed into the wall STEP 3 Once the screws are fixed into the wall insert the four screw heads through the large opening of the keyhole shaped apertures and then slide the AWK 3121 downwards as indicated to the right Tighten the four screws for added stability Wiring Requirements WARNING Safety First Be sure to disconnect the power cord before installing and or wiring your Moxa AWK 3121 WARNING Safety First Calculate the maximum possible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowed for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment You should also pay attention to the following items e Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicular at the intersection point NOTE Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics should be routed separat
4. AWK 3121 Quick Installation Guide Moxa AirWorks Fifth Edition March 2012 e O 2012 Moxa Inc All rights reserved Reproduction without permission is prohibited P N 1802031210013 Overview Moxa s AWK 3121 Access Point Bridge AP Client is ideal for applications that are hard to wire too expensive to wire or use mobile equipment that connects over a TCP IP network The AWK 3121 is rated to operate at temperatures ranging from 25 to 60 C for standard models and 40 to 75 C for extended temperature models and is rugged enough for any harsh industrial environment Installation is easy with either DIN Rail mounting or distribution boxes The DIN Rail mounting ability wide operating temperature range and IP30 housing with LED indicators make the AWK 3121 a convenient yet reliable solution for any industrial wireless application Package Checklist Moxa s AWK 3121 is shipped with the following items If any of these items is missing or damaged please contact your customer service representative for assistance e 1AWK 3121 e 2 Dual band Omnidirectional Antennas 2dBi RP SMA 2 4 amp 5GHz e 1 Quick Installation Guide e 1 Software CD e 1 Moxa Product Warranty Booklet e 1 Cable Holder with a Screw e 2 Protective Caps Installation and Configuration Before installing the AWK 3121 make sure that all items in the Package Checklist are in the box In addition you will need access to a notebook computer or PC eq
5. ally quite small so you may need to use a magnifying glass to see the numbers clearly 2 The pin numbers for both 8 pin and 10 pin RJ45 connectors and ports are typically not labeled on the connector or port Refer to the Pinout diagram above to see how RJ45 pins are numbered ATEX Information use CE DEMKO certification number 10 ATEX 0902666X Ambient range 40 C lt Tamb lt 75 C Certification string Ex nA nL IIC T4 Standards covered EN60079 0 2006 EN60079 15 2005 The conditions of safe usage a The Ethernet Communication Devices are intended for mounting in an IP54 enclosure and used in an area of not more than pollution degree 2 as defined by IEC60664 1 b Conductors suitable for use in an ambient temperature greater than 93 C must be used for the Power Supply Terminal c A4 mm2 conductor must be used when connection to the external grounding screw is utilized d Cables must be suitable for use in an ambient temperature greater than 93 C OnRWNeE 10 A ATTENTION For railway rolling stock applications AWK 3121 devices must use a galvanically isolated power supply that is compliant with the EN 50155 standard LED Indicators The front panel of the Moxa AWK 3121 contains several LED indicators The function of each LED is described in the table below LED Color State Description O Pane b ato on Power is being supplied from power PWR1 Green input z 7 7 off Power
6. d then follow the on screen instructions Step 5 Select the operation mode for the AWK 3121 By default the AWK 3121 s operation mode is set to AP You can change the setting in Wireless Settings gt Basic Wireless Settings if you would like to use the Client mode NOTE To make the change effective you must click Save Configuration to save the change or Restart Save and Restart button to apply all changes Step 6 Test communications We will describe two test methods Use the first method if you are using only one AWK 3121 and use the second method if you are using two or more AWK 3121s Testing method for one AWK 3121 If you are only using one AWK 3121 you will need a second notebook computer B equipped with a WLAN card Configure the WLAN card to connect to the AWK 3121 the default SSID is MOXA and change the IP address of notebook B so that it is on the same subnet as the first notebook A which is connected to the AWK 3121 After configuring the WLAN card establish a wireless connection with the AWK 3121 and open a DOS window on notebook B At the prompt type ping IP address of notebook A and then press the Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make sure the connections are correct Testing method for two or more AWK 3121s If you have tw
7. ely e You can use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is that wiring with similar electrical characteristics can be bundled together e Keep input wiring and output wiring separate e Itis strongly advised that you label wiring to all devices in the system when necessary ATTENTION This product is intended to be supplied by a Listed Power Unit marked Class 2 or LPS and rated O P 12 to 48 VDC minimum 6 W 12 V 0 494 A to 48V 0 121 A 25 C ATTENTION Make sure the external power adaptor includes power cords and plug assemblies provided with the unit is certified and suitable for use in your country Grounding the Moxa AWK 3121 Grounding and wire routing help limit the effects of noise due to electromagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices A ATTENTION This product is intended to be mounted to a well grounded mounting surface such as a metal panel Wiring the Redundant Power Inputs The top two pairs of contacts of the 10 contact terminal block connector on the AWK 3121 s top panel are used for the AWK 3121 s two DC inputs Top and front views of the terminal block connector is shown here STEP 1 Insert the negative positive DC wires into the V V terminals STEP 2 To keep the DC wires from pulling loose ol O use a sma
8. er over Ethernet IEEE 802 1D for Spanning Tree Protocol IEEE 802 1w for Rapid STP Spread Spectrum and Modulation typical e DSSS with DBPSK DQPSK CCK e OFDM with BPSK QPSK 16QAM 64QAM e 802 11b CCK E 11 5 5 Mbps DQPSK 2 Mbps DBPSK 11 Mbps e 802 11a g 64QAM 54 48 Mbps 16QAM 36 24 Mbps QPSK 18 12 Mbps BPSK 9 6 Mbps Operating Channels central frequency US 2 412 to 2 462 GHz 11 channels 5 18 to 5 24 GHz 4 channels EU 2 412 to 2 472 GHz 13 channels 5 18 to 5 24 GHz 4 channels JP 2 412 to 2 472 GHz 13 channels OFDM 2 412 to 2 484 GHz 14 channels DSSS 5 18 to 5 24 GHz 4 channels for W52 Security e SSID broadcast enable disable e Firewall for MAC IP Protocol Port based filtering e 64 bit and 128 bit WEP encryption WPA WPA2 Personal and Enterprise IEEE 802 1X RADIUS TKIP and AES Transmission Rates 802 11b 1 2 5 5 11 Mbps 802 11a g 6 9 12 18 24 36 48 54 Mbps TX Transmit Power 802 11b Typ 2341 5 dBm 1 to 11 Mbps 802 119 Typ 2041 5 dBm 6 to 24 Mbps Typ 1941 5 dBm 36 Mbps Typ 1841 5 dBm 48 Mbps Typ 17 1 5 dBm 54 Mbps 802 11a Typ 18 1 5 dBm 6 to 24 Mbps Typ 16 1 5 dBm 36 to 48 Mbps Typ 15 1 5 dBm 54 Mbps 12 RX Sensitivity 802 11b 97 dBm 1 Mbps 94 dBm 2 Mbps 92 dBm 5 5 Mbps 90 dBm 11 Mbps 802 119 93 dBm 6 Mbps 91 dBm 9 Mbps 90 dBm 12 Mbps 88 dBm 18 Mbps 84 dBm 24 Mb
9. ll flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connector ia View STEP 3 Insert the plastic terminal block connector prongs into the terminal block UV receptor which is located on the AWK 3121 s top panel Co ZDODDD Front View A ATTENTION Before connecting the AWK 3121 to the DC power inputs make sure the DC power source voltage is stable Wiring the Relay Contact The AWK 3121 has one relay output which consists of the two contacts of the terminal block on the AWK 3121 s top panel Refer to the previous section for detailed instructions on how to connect the wires to the terminal block connector and how to attach the terminal block connector to the terminal block receptor These relay contacts are used to indicate user configured events The two wires attached to the Relay contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the Relay circuit will be closed Wiring the Digital Inputs The AWK 3121 has two sets of digital input DI1 and DI2 Each DI comprises two contacts of the 10 pin terminal block connector on the AWK 3121 s top panel You can refer to the Wiring the Redundant Power Inputs section for detailed instructions on how to connect the wires to the terminal block connector and how to attach the terminal block connector to the terminal block receptor Cable Holder Installation Optio
10. nal You can attach the cable holder to the bottom of the AWK 3121 This helps to keep cabling neat and avoid accidents that result from untidy cables STEP 1 Screw the cable holder onto the bottom of the AWK 3121 WSS I S S Communication Connections 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on the AWK 3121 s front panel are used to connect to Ethernet enabled devices Below we show pinouts for both MDI NIC type ports and MDI X HUB Switch type ports MDI Port Pinouts MDI X Port Pinouts 8 pin RJ45 Pin Signal Pin Signal 1 TX 1 Rx h 2 Tx 2 Rx 3 Rx 3 Tx 6 Rx 6 Tx RS 232 Connection The AWK 3121 has one RS 232 8 pin RJ45 console port located on the front panel Use either an RJ45 to DB9 or RJ45 to DB25 cable to connect the Moxa AWK 3121 s console port to your PC s COM port You may then use a console terminal program to access the AWK 3121 for console configuration Console Pinouts for 10 pin or 8 pin RJ45 10 Pin Description 8 Pin 1 2 DSR 1 s 3 RTS 2 4 GND 3 5 TxD 4 6 RxD 5 7 DCD 6 8 CTS 7 9 DTR 8 10 NOTE 1 The pin numbers for male DB9 and DB25 connectors and hole numbers for female DB9 and DB25 connectors are labeled on the connector However the numbers are typic
11. ns 53 6 x 135 x 105 mm 2 11 x 5 31 x 4 13 in Installation DIN Rail mounting wall mounting with optional kit Environmental Limits Operating Temperature Standard Models 25 to 60 C 13 to 140 F Wide Temp Models 40 to 75 C 40 to 167 F 13 Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 5 to 95 non condensing Power Requirements Input Voltage 12 to 48 VDC redundant dual DC power inputs or 48 VDC Power over Ethernet IEEE 802 3af compliant Compliant with EN 50155 on 24 VDC PoE is only available for the AWK 3121 and AWK 3121 M12 Connector 10 pin removable terminal block Power Consumption 12 to 48 VDC 0 121 to 0 494A Reverse Polarity Protection Present Standards and Certifications Safety UL 60950 1 EN 60950 1 Hazardous Location UL cUL Class I Division 2 ATEX Zone 2 for AWK 3121 only EMC EN 301 489 1 17 FCC Part 15 Subpart B EN 55022 55024 Radio EN 300 328 EN 301 893 DSPR Japan Rail Traffic EN 50155 EN 50121 1 4 Note Please check Moxa s website for the most up to date certification status Reliability MTBF mean time between failures AWK 3121 392 209 hrs AWK 3121 M12 480 831 hrs AWK 3121 SSC 445 913 hrs Warranty Warranty Period 5 years Details See www moxa com support warranty aspx A ATTENTION The AWK 3121 is NOT a portable mobile device and should be located at least 20 cm away from the human body The AWK 3121 i
12. o or more AWK 3121s you will need a second notebook computer B equipped with an Ethernet port Use the default settings for 3 the first AWK 3121 connected to notebook A and change the second or third AWK 3121 connected to notebook B to Client mode and then configure the notebooks and AWK 3121s properly After setting up the testing environment open a DOS window on notebook B At the prompt type ping IP address of notebook A and then press Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make sure the connections are correct Panel Layout of the AWK 3121 Top Panel View 1 Grounding screw 2 Terminal block for PWR1 PWR2 1 relay DI1 and DI2 3 Reset button 2 4 4 Heat dissipation orifices 5 System LEDs PWR1i PWR2 PoE FAULT and STATE LEDs 3 6 LEDs for signal strength 7 WLAN LEDs CLIENT BRIDGE and WLAN LEDs 8 RS 232 console port Front Panel View 9 10 100BaseT X RJ45 Port 10 10M LED 11 100M LED 5 12 12 MAIN antenna port 6 13 AUX antenna port 7 14 Model name 8 i 15 Screw hole for wall mounting kit g 16 DIN Rail mounting kit gt 13 11 14 Mounting Dimensions unit mm o Ep o Perera oanaaannneaan ho00000000 oo 135 5 31 151 85 5 98 oo DODII o 97 3 82
13. ps 80 dBm 36 Mbps 76 dBm 48 Mbps 74 dBm 54 Mbps 802 11a 90 dBm 6 Mbps 89 dBm 9 Mbps 89 dBm 12 Mbps 85 dBm 18 Mbps 83 dBm 24 Mbps 79 dBm 36 Mbps 75 dBm 48 Mbps 74 dBm 54 Mbps Protocol Support General Protocols Proxy ARP DNS HTTP HTTPS IP ICMP SNTP TCP UDP RADIUS SNMP PPPoE DHCP Interface Default Antennas 2 dual band omni directional antennas 2 dBi RP SMA male Only available with the AWK 3121 and AWK 3121 SSC models Connector for External Antennas AWK 3121 and AWK 3121 SSC RP SMA female AWK 3121 M12 QMA female RJ45 Ports 1 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection AWK 3121 only Fiber Ports 1 100BaseFX port SC connector AWK 3121 only M12 Ports 1 10 100BaseT X auto negotiation speed F H duplex mode and auto MDI MDI X connection AWK 3121 M12 only Console Port RS 232 RJ45 type LED Indicators PWR1i PWR2 POE FAULT STATE signal strength CLIENT MODE BRIDGE MODE WLAN 10 100 TP port 100M fiber port LAN M12 port PoE is only available for the AWK 3121 and AWK 3121 M12 Alarm Contact 1 relay output with current carrying capacity of 1 A 24 VDC Digital Inputs 2 electrically isolated inputs e 13 to 30 V for state 1 e 3 to 30 V for state O e Max input current 8 mA Physical Characteristics Housing Metal providing IP30 protection Weight 850 g Dimensio
14. s NOT designed for the general public To deploy AWK 3121s and establish a wireless network safely a well trained technician is required for installation A ATTENTION Use the antennas correctly The 2 4 GHz antennas are needed when the AWK 3121 operates in IEEE 802 11b g The 5 GHz antennas are needed for IEEE802 11a Make sure your antenna installation is within a safety area which is covered by a lightning protection or surge arrest system 14 Technical Support Contact Information WWW moxa com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 15
15. uipped with an Ethernet port The AWK 3121 has a default IP address that you must use when connecting to the device for the first time Step 1 Select the power source The AWK 3121 can be powered by a DC power input or PoE Power over Ethernet The AWK 3121 will use whichever power source you choose Step 2 Connect the AWK 3121 to a notebook or PC Since the AWK 3121 supports MDI MDI X auto sensing you can use either a straight through cable or crossover cable to connect the AWK 3121 to a computer If the LED indicator on the AWK 3121 s LAN port lights up it means the connection is established Step 3 Set up the computer s IP address Set an IP address on the same subnet as the AWK 3121 Since the AWK 3121 s default IP address is 192 168 127 253 and the subnet mask is 255 255 255 0 you should set the IP address of the computer to 192 168 127 xxx and subnet mask to 255 255 255 0 Step 4 Use the web based manager to configure AWK 3121 Open your computer s web browser and then type http 192 168 127 253 in the address field to access the homepage of the web based management Before the homepage opens you will need to enter the user name and password For first time configuration enter the default user name and password and then click on the Login button User name admin Password root A ATTENTION For security reasons we strongly recommend changing the password To do so select Maintenance gt Password an