Home

Supermicro SuperChassis 119TQ-R700WB

image

Contents

1. Figure C 1 Front Connectors Front Connectors and Jumpers 1 Power Connectors 4 pin JP10 JP13 10 Connector 5 J12 2 Upgrade Connector JP46 11 Connector 4 J10 3 MG9072 Chip 12 Connector 3 J8 4 Sideband 1 JP51 13 Connector 2 J7 5 Sideband 2 JP52 14 Connector 1 J6 6 lC Connector 1 JP44 15 Connector 0 J5 7 PC Connector 2 JP45 8 Connector Z7 J16 9 Connector 6 J14 C 3 SC113 Chassis Manual C 6 Front Connector and Pin Definitions 1 Backplane Main Power Connectors Backplane g p Main Power The 4 pin connectors designated JP10 provide 4 Pin Connector power to the backplane See the table on the Pin Definition right for pin definitions 1 12V 2and3 Ground 4 5V 2 Upgrade Connector The upgrade connector designated JP46 is for diagnostic purposes only This connector should only be used by a certified and experi enced technician 3 MG9072 Chip The MG9072 is an enclosure management chip that supports the SES 2 controller and SES 2 protocols 4 and 5 Sideband Connectors Sideband Connectors The sideband connectors are designated JP51 Pin Definition Pin Definition and JP52 For SES 2 to work properly you 7 2 SDIN 1 Controller must connect an 8 pin sideband cable See the Backplane ID SB6 table to the right for pin definitions 5 dn 4 SDOUT PC 3 GND SB2 Reset SB4 6 GND SB3
2. 5 SLOAD SDA SB1 8 Backplane 7 SCLOCK ID SB7 SCL SBO 10 No Connec 9 No Connec tion tion C 4 Appendix C SAS 113TQ Backplane Specifications 6 and 7 C Connectors Fe Connector Pin Definiti The I C connectors designated JP44 and 2 2 JP45 are used to monitor HDD activity and E status See the table on the right for pin aoe initi 2 Ground definitions 3 Clock 4 No Connection 8 15 SAS SATA Connectors The SAS SATA connectors are numbered 0 through 7 Each may be connected to the system with a SAS or SATA cable C 5 SC113 Chassis Manual C 7 Front Jumper Locations and Settings nooo A Ix SO usa B Explanation of Jumpers To modify the operation of the backplane jumpers can be used to choose between optional settings Jumpers create shorts A Figure C 2 Front Jumpers Pins between two pins to change the function Jumper of the connector Pin 1 is identified with a sguare solder pad on the printed circuit board Note On two pin jumpers Closed means the jumper is on and Open means the jumper is off the pins Jumper Settings Jumper JP18 JP29 Jumper Settings Open Default Closed Reset Open Default Closed Reset Note Buzzer reset MG9072 chip reset The buzzer sound indicates that a condition reguiring immediate attention has occurr
3. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product California Best Management Practices Regulations for Perchlorate Materials This Perchlorate warning applies only to products containing CR Manganese Dioxide Lithium coin cells Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate WARNING Handling of lead solder materials used in this product may expose you to lead a chemical known to the State of California to cause birth defects and other reproductive harm Manual Revision 1 0 Release Date April 27 2012 Unless you request and receive written permission from Super Micro Computer Inc you may not copy any part of this document Information in this document is subject to change without notice Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders Copyright 2012 by Super Micro Computer Inc All rights reserved Printed in the United States of America Preface Preface About This Manual This manual is written for professional system integrators and PC technicians It provides information for
4. 1 SC119 Chassis Manual 2 4 Electrical Safety Precautions Basic electrical safety precautions should be followed to protect yourself from harm and the SC119 from damage Be aware of the locations of the power on off switch on the chassis as well as the room s emergency power off switch disconnection switch or electrical outlet If an electrical accident occurs you can then quickly remove power from the system Do not work alone when working with high voltage components Power should always be disconnected from the system when removing or install ing main system components such as the serverboard memory modules and the DVD ROM and floppy drives not necessary for hot swappable drives When disconnecting power you should first power down the system with the operating system and then unplug the power cords from all the power supply modules When working around exposed electrical circuits another person who is fa miliar with the power off controls should be nearby to switch off the power if necessary Use only one hand when working with powered on electrical equipment This is to avoid making a complete circuit which will cause electrical shock Use extreme caution when using metal tools which can easily damage any electrical components or circuit boards they come into contact with Do not use mats designed to decrease electrostatic discharge as protection from electrical shock Instead use rubber mats that have been s
5. 2 3 2 0 System Safety csset en eae p decet Le d ca teet opere 2 3 Chapter 3 Chassis Components 3 1 BI H 3 1 2 2 JGOmpOHOnDl s ains erre ep co pee ee Ur e ku sta bobo ROREM aa EE DADA OD 3 1 Chassis Backplane EeePC Power Supply ied icio n e Et naa etii Ein e ec etait Japan 3 2 AE SMM OU ec 3 2 3 3 Where to get Replacement Components ccccceceeeeeeeeeeeeeeeeeeeeeteeeeeeees 3 2 SC119 Chassis Manual Chapter 4 System Interface 4 1 4 2 4 3 4 4 4 5 OMIM echt ae 4 1 Control Panel Buttons 4 2 Control Panel WEDS stint negaret Ania ties heen hn ete vien 4 3 Drive Carner LES uoi aciei a tim aled ceu 4 4 SAS SATA DIiVeS wrth dictated RR e YR Mavens 4 4 Power SUPDIY LEDS mine at al mas ataman aiast ben fot ahistati 4 4 700 Walt Power SUPPIV 1 531334424554 18 sees weave cen cer re rer eerte enia Ee kaalukad 4 4 Chapter 5 Chassis Setup and Maintenance 5 1 5 2 5 3 5 4 5 5 5 6 5 7 5 8 5 9 5 10 5 11 Overview Installation and Maintenance Procedures nrnnrea 5 1 Mita e fof s ne neg eee nese emcees Sep data i nese taan taa a 5 1 General Maimt nanCe AA 5 1 Removing the Chassis Cover and Front Bezel ccsceeeeeeeeeeeeeeeeeteeeees 5 2 Installing Hard Drives eere eere e tees 5 3 DVD ROM Drive Installatio
6. Figure 6 6 Installing the Server into a Telco Rack 6 8 Appendix A Chassis Cables Appendix A SC119 Chassis Cables A 1 Overview This appendix lists supported cables for your system It only includes the most commonly used components and configurations For more compatible cables refer to the manufacturer of the motherboard you are using and our Web site at www supermicro com A 2 Cables Included with SC119 Chassis SAS SATA C119 R700UB Part Type Length Description Round CBL 0227L ribbon 48 cm SATA round S RA PBF cable Round i ja CBL 0157L fibbo 40 cm 8 pin to 8 pin ribbon cable for SGPIO supports up to 4 drives cable Round CBL 0335L Mon 70 cm Front control panel cable 20 pin to 20 pin with tube cable CBL 0206L ee 48 cm 48 cm SATA round S S PBF A 1 SC119 Chassis Manual A 3 Compatible Cables These cables are compatible with the SC119 chassis This section lists cables included with the SC119 chassis packages Alternate SAS SATA Cables Some compatible motherboards have different connectors If your motherboard has only one SAS connector that the SAS SATA cables must share use one ofthe following cables These cables must be purchased separately Cable Name SAS Cable Auantity 1 Part CBL 0175L Alt Name Big Four Description This cable has one SFF 8484 32 pin connector on one end and four SAS connectors seven pins each at the other This cable co
7. chassis using the rounded Phillips head screws Do not exceed eight pounds of torque when tightening the mother board 8 Secure the CPU s heatsinks and other components to the motherboard as needed 5 9 SC119 Chassis Manual Expansion Card Setup SC119 chassis includes I O slots for expansion cards The SC119 R700UB is a U model chassis which includes one low profile and two full height PCI slots for expansion cards Note A riser card must be used to install expansion cards into any SC119 chassis Riser cards are sold separately For the latest compatibility and performance information visit our website at http Awww supermicro com PCI Slots Figure 5 9 SC119 Chassis Rear with Two Full Height Full Length PCI Slots and One Low Profile PCI Slot 5 10 Riser Card Bracket Chapter 5 Chassis Setup and Maintenance Riser Card Riser Card Bracket Screws Figure 5 10 Chassis with a Riser Card Installing Expansion and Riser Cards 1 Confirm that you have the correct riser card for your chassis model and the expansion card includes a standard bracket Remove the chassis cover Install the riser card onto the riser card bracket Insert the card and bracket into the appropriate slot on the motherboard Secure the riser bracket to the chassis using screws as illustrated Choose the PCI slot in which to place t
8. extensions The inner rails are pre attached and do not interfere with normal use of the chassis if you decide not to use a server rack Attach the inner rail extension to stabilize the chassis within the rack Installing the Inner Rail Extensions 1 Place the inner rail extensions on the side of the chassis aligning the hooks of the chassis with the rail extension holes Make sure the extension faces outward just like the pre attached inner rail 2 Slide the extension toward the front of the chassis 3 Secure the chassis with 2 screws as illustrated 4 Repeat steps 1 3 for the other inner rail extension 6 5 SC119 Chassis Manual Attach Outer RailsTogether Secure to the Front of the Rack Secure to the Rear of the Rack Figure 6 3 Assembling the Outer Rails Outer Rails Installing the Outer Rails to the Rack 1 Attach the shorter outer rail to the outside of the longer outer rail You must align the pins with the slides Both bracket ends must face the same direction 2 Adjust the outer rails so that they fit snugly within the rack 3 Secure the longer outer rail to the front of the rack with two screws 4 Secure the shorter outer rail to the rear rack with three screws 5 Repeat steps 1 4 for the remaining outer rail Figure 6 4 Installing the Outer Rails to the Server Rack 6 6 Chapter 6 Rack Installation NSA TT TEETE TT TEETE TT
9. if your motherboard has different pin definitions than a Supermicro motherboard A 3 SC119 Chassis Manual Notes A 4 Appendix B Power Supply Specifications Appendix B SC119 Power Supply Specifications This appendix lists power supply specifications for your chassis system SC119TA R700UB 700W 80 PLUS Gold Certified MFR Part PWS 704P 1R 700W 100 140 V 50 60 Hz 8 5 6 Amps AC Voltage 750W 180 240 V 60 50 Hz 5 3 8 Amps DC Output 5V standby DC Output 700W 58 Amps at 100 140V 442V 750W 62 Amps at 180 240V 5V 25 Amps 3 3V 25 Amps 12V 0 6 Amps 3 Amps With Power Distributor GOLD B 1 SC119 Chassis Manual Notes B 2 Appendix C SAS 113TQ Backplane Specifications Appendix C SAS 113TQ Backplane Specifications To avoid personal injury and property damage carefully follow all the safety steps listed below when accessing your system or handling the components C 1 ESD Safety Guidelines Electrostatic Discharge ESD can damage electronic components To prevent dam age to your system it is important to handle it very carefully The following measures are generally sufficient to protect your equipment from ESD Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not touch i
10. shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws you will need to install the system into the rack Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow Choosing a Setup Location Leave enough clearance in front of the rack to enable you to open the front door completely 25 inches Leave approximately 30 inches of clearance in the back of the rack to allow for sufficient airflow and ease in servicing This product is for installation only in a Restricted Access Location dedicated equipment rooms service closets and the like 6 1 SC119 Chassis Manual A N Warnings and Precautions AN Rack Precautions Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them n single rack installation stabilizers should be attached to the rack n multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable General Server Precautions Review the electrical and general safety precautions that came with the com ponents you are adding to your chassis Determine the placement of each component in the
11. supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connec tions other than the direct connections to the branch circuit such as power strips and other devices 6 3 SC119 Chassis Manual 6 4 Rack Mounting Instructions This section provides information on installing the SC119 chassis into a rack unit with the rails provided There are a variety of rack units on the market which may mean the assembly procedure will vary slightly Refer to the installation instructions that came with the rack unit NOTE This rail will fit a rack between 26 and 33 5 deep Identifying the Sections of the Rack Rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of two sections An inner rail that secures directly to the chassis and an outer rail that secures directly to the rack Inner Rail Extensions Inner Rails Inner rails are pre installed on the chassis Figure 6 1 Identifying the Inner Rails and Inner Rail Extensions Chapter 6 Rack Installation Figure 6 2 Identifying the Sections of the Rack Rails right side rail shown Inner Rail Extension The SC119 chassis includes a set of inner rails in two sections Inner rails and inner rail
12. CN EununsnbUnESIESDEUDEDDESDEUHEDESISUA Figure 6 5 Installing the Rack Rails Installing the Chassis into a Rack 1 Confirm that chassis includes the inner rails and rail extensions and confirm that the outer rails are installed on the rack 2 Align the inner rails on the chassis with the front of the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides it may be necessary to depress the locking tabs when inserting When the server has been pushed completely into the rack you should hear the locking tabs click into the locked position 4 Optional Insert and tighten the thumbscrews that hold the front of the chas sis to the rack 6 7 SC119 Chassis Manual Installing the Chassis into a Telco rack To install the chassis into a Telco type rack use two L shaped brackets on either side of the chassis four total First determine how far follow the server will extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back If a bezel is included on your server remove it Then at tach the two front brackets to each side of the chassis then the two rear brackets positioned with just enough space to accommodate the width of the Telco rack Finish by sliding the chassis into the rack and tightening the brackets to the rack
13. ED Indicators NEC GUN Hard Drive Activity Failure LED SAS 0 D12 D5 SAS 1 D13 D6 SAS 2 D14 D7 SAS 3 D15 D8 SAS 4 D18 D19 SAS 5 D21 D20 SAS 6 D22 D23 SAS 7 D25 D26 C 8 Appendix C SAS 113TQ Backplane Specifications Notes C 9 SC113 Chassis Manual Disclaimer cont The products sold by Supermicro are not intended for and will not be used in life sup port systems medical eguipment nuclear facilities or systems aircraft aircraft devices aircraft emergency communication devices or other critical systems whose failure to per form be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use or sale
14. ROM Drive 5 5 SC119 Chassis Manual 7 Reconnect the data and power cables 8 Replace the chassis cover replace the server in the rack if necessary and power up the system 5 6 Removing the Backplane The SC119 chassis backplane is located behind the hard drives and in front of the front system fans In order to change jumper settings on the backplane it may be necessary to remove the backplane from the chassis Removing the Backplane from the Chassis 1 Disconnect the chassis from any power source 2 Disconnect the cabling to the backplane 3 Remove the five upper screws at the top of the backplane indicated by the arrows below 4 Lift the backplane up and out of the chassis Removing the Screws Figure 5 5 Installing the Backplane 5 6 Chapter 5 Chassis Setup and Maintenance 5 7 Backplane Installation Installing the Backplane 1 Slide the backplane into the chassis as shown inserting the lower edge of the backplane into the clips on the floor of the chassis Align the mounting holes in the backplane with the mounting holes in the chassis Secure the backplane to the chassis using the five screws provided with the backplane Connect the wiring to the backplane Installing the Screws Figure 5 6 Installing the Backplane 5 7 SC119 Chassis Manual 5 8 Installing the Motherboard Figure 5 7 Chassis Standoffs Permanent and Optional Standoffs Standoffs prevent s
15. SUPER SC119 Chassis Series SC119TQ R700UB USER S MANUAL 1 0 SC119 Chassis Manual The information in this User s Manual has been carefully reviewed and is believed to be accurate The vendor assumes no responsibility for any inaccuracies that may be contained in this document makes no commitment to update or to keep current the information in this manual or to notify any person or organization of the updates Please Note For the most up to date version of this manual please see our web site at www supermicro com Super Micro Computer Inc Supermicro reserves the right to make changes to the product described in this manual at any time and without notice This product including software and documentation is the property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except as expressly permitted by the terms of said license IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA
16. UD e UID When used with a UID compatible motherboard the UID button is used to turn on or off the blue light function of the the U LED Once the blue light is activated the unit can be easily located in large racks and server banks Reset The reset button is used to reboot the system Power The main power switch is used to apply or remove power from the power supply to the server system Turning off the system power with this but ton removes the main power but keeps standby power supplied to the system therefore you must unplug system before servicing 4 2 Chapter 4 System Interface 4 3 Control Panel LEDs The control panel located on the front of the SC119 chassis has five LEDs These LEDs provide critical information related to different parts of the system This sec tion explains what each LED indicates when illuminated and any action that may be required e Overheat Fan Fail When this LED flashes it indicates a fan failure When continuously on not flashing it indicates an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm e NIC2 Indicates network activity on GLAN2 when flashing e NIC1 Indicates network activity on GLAN1 when flashing e HDD Indicates IDE channel activity SAS SATA drive SCSI drive and or DVD ROM drive activity when flashing 0 LA Power Indicates power is being s
17. aiEXtensiOMmises cies aetanwece cesta P AO ense ERO EVE I PERDRE da 6 5 Loir ici M 6 6 Installing the Chassis into a Telco rack sssesssssm 6 8 Appendix A SC119 Chassis Cables Appendix B SC119 Power Supply Specifications Appendix C SAS 113TQ Backplane Specifications vii SC119 Chassis Manual Notes viii Chapter 1 Introduction 1 1 Overview Chapter 1 Introduction Supermicro s SC119 1U chassis features a unique and highly optimized design for 1U UIO servers The chassis is equipped with a 700 Watt redundant high efficiency 80 PLUS Gold Level Certified power supply to support high performance system components and high speed heavy duty counter rotating fans for ample cooling The chassis provides maximum features in 1U form factor for high end high performance applications Only enterprise level SAS or SATA hard drives are recommended for use in the SC119 chassis 1 2 Shipping List Visit the Supermicro Web site for the latest shipping lists and part numbers for your particular chassis model at www supermicro com SC119 Chassis Model CPU HDD l O Slots Power Supply SC119TQ R700UB DP 8x SAS SATA 2x FH tx LP 0 799 e Gold Level DP Dual Processor Support FH Full height card LP Low profile card 1 1 SC119 Chassis Manual 1 3 Chassis Features The SC119 1U high performance chassis includes the following feat
18. ck installation You should follow the procedures given in this chapter when installing removing or reconfiguring your chassis into a rack environment Appendices These appendices list compatible cables power supply specifications and com patible backplanes Not all compatible backplanes are listed Refer to our Web site for the latest compatible backplane information at http www supermicro com Appendix A Chassis Cables Appendix B Power Supply Specifications Appendix C SAS 113TQ Backplane Specifications Preface Table of Contents Preface About This Manual cct rrr rne rer rh leere anda eae iii Chapter 1 Introduction 1 1 Overview US EE Tere noa NE 1 1 1 3 Cassis Features unsustainable 1 2 CPU 1 2 unb rcp 1 2 VO EXPANSION SOUS istics tvi ho ter tero et Pocta a Pe te i re cre tre 1 2 Peripheral Drives 1 2 Other Features terre ee epo ri Dese ere rer PR iat 1 2 1 4 Contacting SuperrictO ecrire a tama aka enka Sa 1 3 1 5 Returning Merchandise for Service 1 4 Chapter 2 System Safety 2 1 VebVIB Ws ciui eise tnetnie dio afe estreno tust deos asa i cete dcn Md a tatar 2 1 2 2 Warnings and Preca tiolis ede cred e ende e dress 2 1 2 3 Preparing for Setup 2 4 Electrical Safety Precautions cc cien co cede cn 2 2 2 5 General Safety Precautions ee rete e ERR RH SHEER RR XE RESTER BSa
19. ed The buzzer alarm is triggered by the following conditions 1 Hard drive failure 2 System temperature over 45 Celsius C 6 Appendix C SAS 113TQ Backplane Specifications PC and SGPIO Modes and Jumper Settings This backplane can utilize C or SGPIO SGPIO is the default mode and can be used without making changes to your jumpers The following information details which jumpers must be configured to use C mode or restore your backplane to SGPIO mode PC and SGPIO Settings Jumper PC Jumper Setting SGPIO Jumper Setting Default Note JP33 2 3 12 Controller ID Front LED Indicators Figure C 3 Front LEDs Front Panel LEDs LED State Specification D3 On Overheat or Drive Failure C 7 SC113 Chassis Manual 2 4 Rear Connectors and LED Indicators SAS 3 SAS 5 Mam sss i SS 7 Figure C 4 Rear Connectors Rear SAS SATA Connectors Rear Connector SAS SATA Drive Connector Number Number SAS 0 J1 SAS SATA HDD 0 SAS 1 J2 SAS SATA HDD 1 SAS 2 J3 SAS SATA HDD 2 SAS 3 J4 SAS SATA HDD 3 SAS 4 J9 SAS SATA HDD 44 SAS 45 J11 SAS SATA HDD 5 SAS 6 J13 SAS SATA HDD 6 SAS 7 J15 SAS SATA HDD 7 ACT 1 ACT 3 ACT 5 FAIL 1 FAIL 3 FAIL 5 ACT 6 FAIL 6 NY Y 3 t Ed i Cnm ui m fitr uo fr 2 ACT FAIL 0 FAIL 2 FAIL 4 FAIL 7 Figure C 5 Rear LEDs Rear L
20. er airflow and prevent overheating Warning Except for short periods of time do NOT operate the 5 2 Chapter 5 Chassis Setup and Maintenance 5 4 Installing Hard Drives Figure 5 2 Removing a Hard Drive The SC119 chassis supports eight hot swappable hard drives so it is not necessary to power down the server when replacing hard drives Only enterprise level SAS or SATA hard drives are recommended for use in Supermicro chassis Removing Hard Drive Carriers from the Chassis 1 Press the release button on the drive carrier This extends the drive carrier handle 2 Use the handle to pull the drive out of the chassis 5 3 SC119 Chassis Manual Figure 5 3 Hard Drive Carrier Installing a Hard Drive into a Drive Carrier T Remove the dummy drive which comes pre installed in the drive carrier by removing the screws securing the dummy drive to the carrier Insert a hard drive into the carrier with the PCB side facing down and the connector end toward the rear of the carrier Align the drive in the carrier so that the mounting holes of the carrier align with those in the hard drive Secure the drive to the carrier with four M3 screws as illustrated below These screws are included in the chassis accessory box Insert the drive carrier into an empty drive bay keeping the carrier oriented so that the hard drive is on the top of the carrier and the release button is on the right side When the carri
21. er chassis provides excellent conductivity between the power supply the case the mounting fasteners and the serverboard 2 4 Chapter 3 Chassis Components Chapter 3 Chassis Components 3 1 Overview This chapter describes the most common components included with your chassis Some components listed may not be included or compatible with your particular chassis model For more information see the installation instructions detailed later in this manual 3 2 Components Chassis The chassis includes eight 2 5 hard drive bays and one slim DVD ROM drive On some chassis models the DVD ROM is an optional item For the latest shipping lists visit our Web site at http www supermicro com This chassis accepts a 1U backplane five fans with an optional sixth fan and two power supplies SC119 models come in black Backplane Each SC119 chassis comes with a 1U SAS SATA backplane For more informa tion regarding compatible backplanes view the appendices found at the end of this manual In addition visit our Web site for the latest information http www supermicro com Fans The SC119 chassis accepts five system fans and provides space for one ad ditional fan if required System fans for the SC119 chassis are powered from the serverboard These fans are 1U high and have 4 pin connectors Mounting Rails The SC119 can be placed in a rack for secure storage and use To setup your rack follow the step by step instr
22. er reaches the rear of the bay the release handle will retract Push the handle in until it clicks into the locked position IN Warning Except for short periods of time swapping hard drives do not operate the server with the hard drives empty 5 4 Chapter 5 Chassis Setup and Maintenance 5 5 DVD ROM Drive Installation The SC119 chassis models support an optional DVD ROM Installing or Replacing a DVD ROM Drive 1 Power down the system and if necessary remove the server from the rack and the front bezel from the chassis Remove the chassis cover Unplug the drive s power and data cables from the motherboard and or back plane If installing a DVD ROM for the first time Unlock the mini bezel lock scew and remove the mini bezel grate from the drive bay The bezel can be removed by pulling out the hard drive beneath the DVD ROM then pulling the mini bezel forward When installing or removing a DVD ROM drive the mini bezel lock screw must be removed and the drive tray must be completely seperated from the chassis If replacing an existing DVD ROM Pull the DVD ROM drive tray from the front of the chassis Remove the DVD ROM from the drive tray by removing the drive screws then secure the replacement DVD ROM into the drive tray using the drive screws Reattach the drive tray to the chassis by replacing the mini bezel lock screw and tightening it from inside the chassis Figure 5 4 Installing the DVD
23. he chassis Pull all excess cabling out of the airflow path or use shorter cables 4 The control panel LEDs inform you of system status including system tem perature See Chapter 3 System Interface for details on the control panel LEDs 5 14 Chapter 5 Chassis Setup and Maintenance 5 10 System Fans Figure 5 14 System Fans in the Fan Tray Optional Sixth Fan Shown in Illustration Five heavy duty fans provide cooling for the chassis These fans circulate air through the chassis as a means of lowering the chassis internal temperature The SC119 chassis contains counter rotating fans Each fan unit is actually made up of two fans joined back to back which rotate in opposite directions This counter ro tating action generates exceptional airflow and works to dampen vibration levels The SC119 chassis provides an additional open space in the fan housing where one additional optional system fan may be added for optimal cooling Adding a System Fan 1 Turn off the power to the system and unplug the system from the outlet 2 Remove the dummy fan from the fan tray 3 Place the new fan into the vacant space in the tray while making sure the ar rows on the top of the fan indicating air direction point in the same direction as the arrows on the other fans 4 Connect the fan wires to the fan headers on the serverboard 5 Power up the system and check that the fan is working properly before re placing the chas
24. he expansion card In that slot open the PCI slot lever and slide the PCI slot cover sideways From inside the chassis remove the PCI slot cover Slide the expansion card into the riser card 5 11 SC119 Chassis Manual Figure 5 11 Add On Card Bracket Installation 8 Attach the expansion card bracket in place of the I O panel Figure 5 12 Add On Card Installation 9 Secure the expansion card by closing the PCI slot lever 10 Connect cables to the expansion card if necessary 5 12 Chapter 5 Chassis Setup and Maintenance 5 9 Installing the Air Shroud Air shrouds concentrate airflow to maximize fan efficiency The SC119 chassis air shroud does not require screws to set up Figure 5 13 Air Shroud Installation Air Shroud Installation 1 Disconnect the chassis from any power source 2 Align the notch on the air shroud with the screw on the side of the fan tray 3 Lower the air shroud into position sliding the notch over the screw on the side of the fan tray 5 13 SC119 Chassis Manual Checking the Air Flow Check the Airflow 1 Make sure there are no objects to obstruct airflow in and out of the server In addition if you are using a front bezel make sure the bezel s filter is replaced periodically 2 Do not operate the server without drives or drive carriers in the drive bays Use only recommended server parts 3 Make sure no wires or foreign objects obstruct air flow through t
25. hort circuits by creating space between the motherboard and the chassis surface The SC119 chassis includes permanent standoffs in locations used by most motherboards These standoffs accept the rounded Phillips head screws included in the SC119 accessories packaging Some motherboards require additional screws to secure heatsinks general com ponents and or non standard components Optional standoffs are included for these motherboards To use an optional standoff you must place the hexagonal screw through the bottom the chassis and secure the screw with the hexagon nut rounded side up 5 8 Chapter 5 Chassis Setup and Maintenance Motherboard Installation Installing the Motherboard 1 Review the documentation that came with your motherboard Become familiar with component placement requirements and precautions 2 Disconnect the chassis from any power source and lay it on a flat surface 3 Open the chassis cover 4 f necessary remove the riser card To do this remove the two screws hold ing the card in place and lift the card from the chassis 5 Compare the mounting holes in the motherboard to those in the chassis Add or remove the removable standoffs as needed To do this A Place a hexagonal standoff screw through the bottom the chassis B Secure the screw with the hexagon nut rounded side up 6 Lay the motherboard on the chassis aligning the permanent and optional standoffs 7 Secure the motherboard to the
26. lose the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made System Safety Electrostatic discharge ESD is generated by two objects with different electrical charges coming into contact with each other An electrical discharge is created to neutralize this difference which can damage electronic components and printed circuit boards The following measures are generally sufficient to neutralize this difference before contact is made to protect your equipment from ESD Do not use mats designed to decrease electrostatic discharge as protection from electrical shock Instead use rubber mats that have been specifically designed as electrical insulators Use a grounded wrist strap designed to prevent static discharge Keep all components and printed circuit boards PCBs in their antistatic bags until ready for use Touch a grounded metal object before removing any board from its antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap 2 3 SC119 Chassis Manual Handle a board by its edges only do not touch its components peripheral chips memory modules or contacts When handling chips or modules avoid touching their pins Put the serverboard and peripherals back into their antistatic bags when not in use For grounding purposes make sure your comput
27. lugged in and turned off or the system is off but in an abnormal state 4 4 Chapter 5 Chassis Setup and Maintenance Chapter 5 Chassis Setup and Maintenance 5 1 Overview This chapter covers the steps required to install components and perform main tenance on the chassis The only tool needed to install components and perform maintenance is a Phillips screwdriver 5 2 Installation and Maintenance Procedures Installation Removing the Chassis Cover and Front Bezel Installing Hard Drives DVD ROM Installation Backplane Installation Installing the Motherboard includes standoff installation and expansion card setup Installing the Air Shroud and Checking the Airflow General Maintenance General Maintenance Systems Fans General Maintenance Replacing the Power Supply Review the warnings and precautions listed in the manual be fore setting up or servicing this chassis These include infor mation in Chapter 2 System Safety and the warning precau tions listed in the setup instructions 5 1 SC119 Chassis Manual 5 3 Removing the Chassis Cover and Front Bezel Figure 5 1 Removing the Chassis Cover Removing the Chassis Cover 1 Disconnect the chassis from any power source Remove the screws securing the top cover to the chassis Slide the cover toward the rear of the chassis Lift the cover up and off the chassis server without the cover in place The chassis cover must be in place to allow prop
28. n 5 5 Re movitig the Backplane vives 5 2 Sect Ee tope ta EC 5 6 Backplane Installation iioc terit te i 5 7 Installing the Motlierboard isi dete aac 5 8 Permanent and Optional Standoffs sssssssssssseeeeenes 5 8 Motherboard Installatiori pee terrere eoe eerte Eo optet aula Expansion Card Setup Installing the Air Shiroud irit t rr nre ge prc ee Checking the Air FIOW nieanneneenannnnannannaneneennnenannannanaanaannna Systems alls acier ee i re vecti eee rne red p reina erige Power Supply f ailute c davidii dik eee Bede reae Chapter 6 Rack Installation 6 1 6 2 6 3 Overview Unpacking theSyselm ec edet occorre A hia Preparing for Setup s eter re tte Renee aata Choosing a Setup Location ssi uc to ete ee ten Rack AR FO CAULOMS NIRE ERI a ETT General Server Precautioris 2 nes ee eee pacte LE kka ce ce Rack Mounting Considerations Ambient Operating Temperature cccecseceeeeeeteeeeeeeaeeeeetseeeeetenneeens 6 3 FREGUCEO A IMOW Me PP 6 3 vi Preface Mechanical Eoaditigi ore oer eie ck Pe Eee tee Msta Circuit Overloadingi uite Io Deiode eas tad ia odia cuui deca Reliable Ground 2 reor ertet so daa kavadele bn RR oven de Rack Mounting Instructions Identifying the Sections of the Rack Rails esessessssseses 6 4 Inner R
29. nnects from the host motherboard or other controller to the backplane SAS hard drive port Cable Name SAS Cable Quantity 1 Part CBL 0116 Alt Name iPass or Small Four Description This cable has one iPass SFF 8087 Mini SAS connector 36 pin at one end and four SAS connectors on the other end This cable connects from the host motherboard or other controller to the backplane SAS hard drive port A 2 Appendix A Chassis Cables Extending Power Cables Although Supermicro chassis are designed with to be efficient and cost effective some compatible motherboards have power connectors located in different areas To use these motherboards you may have to extend the power cables to the moth erboards To do this use the following chart as a guide Power Cable Extenders Number of Pins Cable Part Length 24 pin CBL 0042 7 9 20 cm 20 pin CBL 0059 7 9 20 cm 8 pin CBL 0062 7 9 20 cm 4 pin CBL 0060 7 9 20 cm Front Panel to the Motherboard The SC119 chassis includes a cable to connect the chassis front panel to the motherboard If your motherboard uses a different connector use the following list to find a compatible cable Front Panel to Motherboard Cable Ribbon Cable Front Panel Motherboard Cable Part Tein 16 pin CBL 0049 16 pin 20 pin CBL 048 Apin 20 pin CBL 0047 16 pin Split CBL 0068 2E Split CBL 0067 Split cables Use these cables
30. over Replacing the power supply is simple and requires no tools Replacing the Power Supply 1 Push the release button on the corner of the failed power supply 2 Pull the power supply out using the handle 3 Replace the power supply with another of the same model and push it into the chassis until it clicks into the locked position Handle m BAUS hi Na i a ra Ups EEE o MEG Release Button Figure 5 16 Replacing the Power Supplies 5 17 SC119 Chassis Manual Notes 5 18 Chapter 6 Rack Installation Chapter 6 Rack Installation 6 1 Overview This chapter provides a quick setup to install the chassis into a rack Following these steps in the order given should enable you to have the system installed within a minimal amount of time 6 2 Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way If the chassis itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold your chassis It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need to place the system near a grounded power outlet Be sure to read the Warnings and Precautions in the next section 6 3 Preparing for Setup The box your chassis was
31. pecifically designed as electrical insulators The power supply power cord must include a grounding plug and must be plugged into grounded electrical outlets Serverboard battery CAUTION There is a danger of explosion if the onboard battery is installed upside down which will reverse its polarities This battery must be replaced only with the same or an equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions DVD ROM laser CAUTION this server may have come equipped with a DVD ROM drive To prevent direct exposure to the laser beam and hazardous radiation exposure do not open the enclosure or use the unit in any uncon ventional way Chapter 2 System Safety 2 5 2 6 General Safety Precautions Keep the area around the chassis clean and free of clutter Place the chassis top cover and any system components that have been re moved away from the system or on a table so that they won t accidentally be stepped on While working on the system do not wear loose clothing such as neckties and unbuttoned shirt sleeves which can come into contact with electrical circuits or be pulled into a cooling fan Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present After accessing the inside of the system c
32. rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work up Use a regulating uninterruptible power supply UPS to protect the server from power surges voltage spikes and to keep your system operating in case of a power failure Allow the hot swappable hard drives and power supply modules to cool before touching them Always keep the rack s front door and all panels and components on the servers closed when not servicing to maintain proper cooling Chapter 6 Rack Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient operating tempera ture of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient tempera ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power
33. sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Super Micro Computer Inc 4F No 232 1 Liancheng Rd Chung Ho 235 Taipei County Taiwan R O C 886 2 8226 5990 886 2 8226 3991 www supermicro com tw Technical Support Email Tel support supermicro com tw 886 2 8226 5990 1 3 SC119 Chassis Manual 1 5 Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required be fore any warranty service will be rendered You can obtain service by calling your vendor for a Returned Merchandise Authorization RMA number When returning to the manufacturer the RMA number should be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is complete For faster service RMA authorizations may be requested online http www supermicro com support rma Whenever possible repack the chassis in the original Supermicro carton using the original packaging material If these are no longer available be sure to pack the chassis securely using packaging material to surround the chassis so that it does not shift within the carton and become damaged during shipping This warranty only covers normal consumer use and does not cover damages in curred in shipping or from fail
34. sis cover 5 15 SC119 Chassis Manual Figure 5 15 Chassis Fans Replacing a System Fan 1 If necessary open the chassis while the power is running to determine which fan has failed Never run the server for an extended period of time with the chassis open Turn off the power to the system and disconnect the chassis from any power source Unscrew the two screws securing the fan tray to the floor of the chassis Remove the failed fan s power cord from the serverboard Push upward on the bottom of the fan to remove it from the fan tray Place the new fan into the vacant space in the tray while making sure the ar rows on the top of the fan indicating air direction point in the same direction as the arrows on the other fans Reconnect the fan wires to the exact same chassis fan headers as the previ ous fan Power up the system and check that the fan is working properly before re placing the chassis cover 5 16 Chapter 5 Chassis Setup and Maintenance 5 11 Power Supply The SC119 chassis includes redundant 700W power supplies These power supplies are auto switching capable The power supply automatically senses and operates at a 100v to 240v input voltage An amber light will be illuminated on the power supply when the power is off Agreen light indicates that the power supply is operating Power Supply Failure In the unlikely event that one of the power supplies fails the redundant power supply will take
35. the installation and use of the SC119 1U chassis Installation and maintenance should be performed by experienced technicians only This manual lists compatible parts available when this document was published Always refer to the our Web site for updates on supported parts and configurations SC119 Chassis Manual Manual Organization Chapter 1 Introduction The first chapter provides a list of the main components included with this chas sis and describes the main features of the SC119 chassis This chapter also includes contact information Chapter 2 System Safety This chapter lists warnings precautions and system safety You should thorough ly familiarize yourself with this chapter for a general overview of safety precau tions that should be followed before installing and servicing this chassis Chapter 3 Chassis Components Refer here for details on this chassis including the fans bays airflow shields and other components Chapter 4 System Interface This chapter provides details on the system interface which includes the func tions and information of he control panel LEDs and other LEDs located through out the system Chapter 5 Chassis Setup and Maintenance Refer to this chapter for detailed information on this chassis You should follow the procedures given in this chapter when installing removing or reconfiguring your chassis Chapter 6 Rack Installation This chapter covers detailed information on chassis ra
36. ts components peripheral chips memory modules or gold contacts When handling chips or modules avoid touching their pins Put the card and peripherals back into their antistatic bags when not in use General Safety Guidelines Always disconnect power cables before installing or removing any components from the computer including the SAS 113TQ backplane Disconnect the power cable before installing or removing any cables from the backplane Make sure that the SAS 113TQ backplane is securely and properly installed on the motherboard to prevent damage to the system due to power shortage C 1 SC113 Chassis Manual C 3 An Important Note to Users All images and layouts shown in this user s guide are based upon the latest back plane revision available at the time of publishing The card you have received may or may not look exactly the same as the graphics shown in this manual C 4 Introduction to the SAS 113TA Backplane The SAS 113TQ backplane has been designed to utilize the most up to date tech nology available providing your system with reliable high quality performance This manual reflects SAS 113TQ Revision 1 02 the most current release available at the time of publication Always refer to the Supermicro Web site at www supermi cro com for the latest updates compatible parts and supported configurations C 2 Appendix C SAS 113TQ Backplane Specifications Connectors Jumpers and LEDs C 5 Front Connectors
37. uctions included in this manual 3 1 SC119 Chassis Manual Power Supply Each SC119 chassis model includes redundant high efficiency power supplies rated at 700 Watts In the unlikely event of a power supply failure the hot swappable power supply can be replaced without powering down the system Air Shroud Air shrouds are shields usually plastic that channel air directly to where it is needed Always use the air shroud included with your chassis 3 3 Where to get Replacement Components Although not frequently you may need replacement parts for your system To ensure the highest level of professional service and technical support we strongly recommend purchasing exclusively from our Supermicro Authorized Distributors System Integrators Resellers A list of Supermicro Authorized Distributors System Integrators Reseller can be found at http www supermicro com Click the Where to Buy link 3 2 Chapter 4 System Interface Chapter 4 System Interface 4 1 Overview There are LEDs on the control panel and on the drive carriers that provide system and component status This chapter explains the meanings of these LED indicators and the appropriate responses that need to be taken Figure 4 1 Control Panel Buttons and LEDs 4 1 SC119 Chassis Manual 4 2 Control Panel Buttons The SC119 chassis includes three push buttons located on the front panel a reset button a power on off button and a UID button
38. upplied to the system s power supply units This LED should normally be illuminated when the system is operating 4 3 SC119 Chassis Manual 4 4 Drive Carrier LEDs The SC119 chassis uses SAS SATA hard drives SAS SATA Drives Each SAS SATA drive carrier has two LEDs Green Each Serial ATA drive carrier has a green LED When illuminated this green LED on the front of the SATA drive carrier indicates drive activity A con nection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Red The red LED to indicate an SAS SATA drive failure If one of the SAS SATA drives fail you should be notified by your system management software 4 5 Power Supply LEDs The SC119 chassis includes redundant power supplies which are hot swappable allowing for the power supply to be changed without powering down the system The power supply has an LED on the rear with the following definitions 700 Watt Power Supply 700W Power Supply LEDs State Indication Solid Green System is on Solid Amber System is off and plugged in or 5V stand by on Blinking Amber Power supply internal temperature Only for 700W 3 4 has reached 63 Celsius and will be shut down if the temperature reaches 70 Celsius Solid Green When illuminated the green LED indicates that the power supply is on Solid Amber When illuminated the amber LED indicates the power supply is p
39. ure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems 1 4 Chapter 2 System Safety Chapter 2 System Safety 2 1 Overview This chapter provides a quick setup to get your chassis up and running Following the steps in the order given should enable you to have your chassis set up and operational within a minimal amount of time This quick setup assumes that you are an experienced technician famailiar with common concepts and terminology 2 2 Warnings and Precautions You should inspect the box the chassis was shipped in and note if it was damaged in any way If the chassis itself shows damage file a damage claim with carrier who delivered your system Decide on a suitable location for the rack unit that will hold that chassis It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated The system must be placed near at least one grounded power outlet When con figured the SC119 chassis includes two redundant power supplies and requires two grounded outlets 2 3 Preparing for Setup The SC119 chassis includes a set of rail assemblies including mounting brackets and the mounting screws you will need to install the systems into the rack Please read this manual in its entirety before you begin the installation procedure 2
40. ures CPU The SC119 chassis supports a dual CPU Please refer to the motherboard specifica tion pages on our Web site for updates on supported processors Hard Drives The SC119 chassis features eight hard drive bays for 2 5 hot swappable SAS SATA drives Once setup correctly these drives can be removed without powering down the server I O Expansion Slots The SC119 chassis includes either one full height PCI slot or two full height PCI slots and one low profile PCI slot See the chart on the previous page for your specific chassis model Peripheral Drives Each SC119 chassis supports one slim DVD ROM drive optional This drive allows data to be quickly installed or saved Other Features Other onboard features are included to promote system health These include five or six cooling fans a convenient power switch reset button and five LED indicators 1 2 Chapter 1 Introduction 1 4 Contacting Supermicro Headquarters Address Tel Fax Email Web Site Europe Address Tel Fax Email Asia Pacific Address Tel Fax Web Site Super Micro Computer Inc 980 Rock Ave San Jose CA 95131 U S A 1 408 503 8000 1 408 503 8008 marketing supermicro com General Information support supermicro com Technical Support www supermicro com Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands 31 0 73 6400390 31 0 73 6416525

Download Pdf Manuals

image

Related Search

Related Contents

Siig SC-SA0M11-S1  White Rodgers 1F85RF-275 Specification Sheet (French)  MTD 21A-420-000 Tiller User Manual  Desa (V)TC36GPE Series User's Manual  AQUACROP - Gestion Intégrée des Ressources en Eau (GIRE)  MyReport  Seavus Project Viewer White Paper  Pour les associations  Samsung Galaxy Tab  

Copyright © All rights reserved.
Failed to retrieve file