Home

Rosewill RGS-1016 network switch

image

Contents

1. osewill 16 Ports Gigabit Switch RGS 1016 User Manual o eee COPYRIGHT amp TRADEMARKS Hiosewiti Specifications are subject to change without notice isa registered trademark of Rosewill Inc Other brands and product names are trademarks or registered trademarks of their respective holders No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from Rosewill Inc Copyright 2010 Rosewill Inc All rights reserved http www rosewill com FCC STATEMENT C This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati
2. 100 1000 Mbps and auto MDI MDIX cross over detection functions This function provides true plug and play capability These ports can operate in half duplex mode for 10 100 Mbps LEDs Definition The switch contains one power LED for the device Link Act LEDs for each port that shows the activities and information of the ports LED Status Operation Power Steady Green The switch is powered on Off The switch is powered off Steady Green Valid port connection ape Valid port connection and there is ene Blinking Green data transmitting receiving Off Port disconnected Rear Panel The back panel is shown as bellow it contains a three pronged receptacle 16 Port 19 inch Model Power Receptacle To be compatible with the electric service standards around the world the switch is designed to afford the power supply in the range from 100 to 240VAC 50 60Hz Please make sure that your outlet standard to be within this range To power on the switch plug the female end of the power cord firmly into the receptacle of the switch and the other end into an electric service outlet After the power cord installation please check if the power LED is illuminated for a normal power status Installation This switch can be mount in the rack or mount on the wall You can choose the suitable one to install your device Before installing the switch we strongly recommend The switch is placed wit
3. Reconnect all the cables Network Cables In making a switch interconnection you could use any port to connect another switch with straight or crossover cable As all the ports support auto MDI MDI X function using a straight cable to make a switch to switch connection is allowed 1 Crossover or straight through cable All the ports on the switch support Auto MDI MDI X functionality Both straight through or crossover cables can be used to connect the switch with PCs as well as other devices like switches hubs or router 2 Category 3 4 5 5e or 6 UTP STP cable To make a valid connection and obtain the optimal performance appropriate cables corresponding to different transmitting receiving speed is required To choose a suitable cable please refer to the following table 10 100 1000 10Mbps Category 3 4 5 UTP STP Mbps 100Mbps Category 5 UTP STP copper 1000Mbps Category 5e 6 UTP STP Network Application INTERNET Gigabit Router arrra Switch 100Mbps Switch k sau H sf 1000Mbps Switch EAn SS 7 pra Storage Network ay ayay ee Pc PC PC Product Specifications IEEE802 3 10BASE T IEEE802 3u 100BASE TX IEEE802 3ab 1000BASE T IEEE802 3x full duplex flow control IEEE802 3az Energy Efficient Ethernet IEEE802 1p QoS Standard Interface 16x 10 100 1000 Mbps Ru 45 ports RJ 45 10BASE T Category 3 4 5 UTP STP RJ 45 100BASE TX Category 5 UTP STP
4. RJ 45 1000BASE T Category 5e 6 or enhanced UTP STP 10 100 1000 Mbps Auto negotiation 10 100Mbps Full duplex Half duplex 1000Mbps Full duplex a cpt System Power LED Indications Ports Link ACT MAC Address Table 8K Buffer Memory 256K bytes Jumbo Frame 9K bytes QoS 802 1p 4 Queues Operating Temperature 0 40 C Operating Temperature Storage Temperature 10 70 C Operating 10 90 non condensing Storage 5 90 non condensing Internal power supply 5V 2A Power Supply 100 240V 50 60 He 0 5A MAX universal input Emission FCC CE VCCI Class A Cable Connections Network Data Rate Transmission Mode Operating Humidity Appendix A Troubleshooting 1 The Power LED is not lit gt Make sure the AC power cord connected the Switch with power source properly gt Make sure the power source is ON 2 The Link Act LED is not lit when a device is connected to the corresponding port gt Make sure that the cable connectors are firmly plugged into the Switch and the device gt Make sure the connected device is turned on and working well gt The cable must be less than 100 meters long 328 feet Thank you for purchasing a quality Rosewill Product Please register your product at www rosewill com for complete warranty information and future support for your product Rosewill Customer Service Hotline 1 800 575 9885 Rosewill Customer Service Support techsupport rosewill com
5. h appropriate ventilation environment A minimum 25mm space around the unit is recommended i The switch and the relevant components are away from sources of electrical noise such as radios transmitters and broadband amplifiers The switch is away from environments beyond recommend moisture Wall mount Installation 1 Screw the two provided screws into the wall 150 mm apart horizontally Leave a small gap between the head of the screw and the wall The gap should be big enough for the screw heads to slide into the screw slots and the connection cables to run down the back of the switch 2 Align the holes on the back of the switch with the screws on the wall Hang the switch on the screws Warning Do not wall mount the product vertically or it will be dangerous Please attach the product on the wall horizontally See the image below for reference Wrong direction R Right direction horizontal vertical Rack mount Installation Procedures to rack mount the switch in the rack t 2 3 First disconnect all the cables from the switch Place the unit the right way up on a hard flat surface with the front facing you Locate a mounting bracket over the mounting holes on one side of the unit Insert the screws and fully tighten with a suitable screwdriver Repeat the two previous steps for the other side of the unit 6 Insert the unit into the rack with suitable screws 7
6. he power adaptor or cord and do not place the product where anyone can walk on the power adaptor or cord Do not use the device if the power adaptor or cord is damaged as it might cause electrocution If the power adaptor or cord is damaged remove it from the power outlet Do not attempt to repair the power adaptor or cord Contact your local vendor to order a new one Do not use the device outside and make sure all the connections are indoors Do not obstruct the device ventilation slots as insufficient airflow may harm your device Do not use this product near water eg in wet basement or near a swimming pool Do not expose your device to dampness dust or corrosive liquids Do not install use or service this device during a thunderstorm There is a remote risk of electric shock from lightning Connect ONLY suitable accessories to the device Do not open the device or unit Opening or removing covers can expose you to dangerous high voltage points or other risks ONLY qualified service personnel should service or disassemble this device Please contact your vendor for further information Make sure to connect the cables to the correct ports If you wall mount your device make sure that no electrical lines gas or water pipes will be damaged Your product is marked with this symbol which is known as the WEEE mark WEEE stands for Waste Electronics and Electrical Equipment It means that used electrical and electronic produc
7. on between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE USER S AUTHORITY TO OPERATE THE EQUIPMENT CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Safety Warning Place connecting cables carefully so that no one will step on them or stumble over them Always disconnect all cables from this device before servicing or disassembling Use ONLY an appropriate power adaptor or cord for your device Connect the power adaptor or cord to the right supply voltage for example 110V AC in North America or 230V AC in Europe Do not allow anything to rest on t
8. r Idle Mode and save power consumption Key Features Supports IEEE 802 3az Energy Efficient Ethernet 16 port auto sensing 10 100 1000 Mbps Ethernet connections Bandwidth 32 Gbps non blocking Supports NWay protocol for speed 10 100 1000Mbps and duplex mode Half Full auto detection Supports MDI MDI X auto crossover and polarity correction Store and forward architecture filters fragment amp CRC error packets Supports 802 3az Green Ethernet Detecting port usage power saving and cable length power saving Forward rate 100 Mbps port 148 800 packet per sec Forward rate 1000 Mbps port 1 488 000 packet per sec Supports 8K bytes MAC address Queue Buffer Memory 256 Kbytes Supports 9K bytes jumbo frame 802 1p Quality of Service QoS priority support up to 4 queues Acoustic Noise 0 dB Latency 1000 to 1000Mbps Frame size 64 bytes Latency is 5 4 microsecond Max Frame size 1518 bytes Latency is 17 2 microsecond Max Integrates 10 100 amp 1000 Mbps devices within a network Delivers up to 2000 Mbps on each port Rack Mount Design Non blocking Architecture Supports extensive LED indicators for network diagnostics Store and forward architecture filters fragment amp CRC error packets Front Panel The front panel consists of LED indicators and the ports 16 Port 19 inch Model Gigabit Ethernet Ports The switch includes 16 gigabit twisted pair ports each supporting auto negotiable 10
9. ts should not be mixed with general waste Used electrical and electronic equipment should be treated separately a Package Contents The following contents should be found in your package gt One RGS 1016 Switch gt One power cord gt This User Guide gt Rubber footpads gt Rack mount kit for installing the switch in a 19 inch rack Note Ca Make sure that the package contains the above items If any of the listed items are damaged or missing please contact with your distributor Introduction Easily boost your networking throughput this switch provides you 16 10 100 1000 Mbps gigabit ports that lead you to a real gigabit connection Users are now able to transfer large and high bandwidth needed files faster and hence get a real efficiency improvement The store and forward architecture filters errors and forwards packets in a non blocking environment Flow control ensures the correctness of data transmitting The 802 3x and backpressure flow control mechanisms work respectively for full and half duplex modes The switch features with easy installation and maintenance It supports NWay auto negotiation protocol which detects the networking speed and the duplex modes automatically Auto MDI MDI X function alleviates the effort to use crossover cables Users need not to prepare crossover cables for equipment connectivity It also supports IEEE 802 3az Energy Efficient Ethernet to promise the operation in Low Powe

Download Pdf Manuals

image

Related Search

Related Contents

Bienvenida  DTI-300A User Manual  2013 年度 化学プロセス工学実験テキスト  Radio Shack 14-1128 User's Manual  Honda SB7038 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file