1. 1 Lo Cable management bar Front panel of chassis Bottom of chassis Screws 4 3 6 Matrix N7 Chassis Setup Setting Up the Matrix N7 Chassis 3 2 3 Rack Mounting the Matrix N7 Chassis The Matrix N7 chassis can be mounted in a standard 48 26 centimeter 19 inch equipment rack To rack mount the chassis into a rack you need to e allow at least 60 centimeters 24 inches of clearance in front of the rack for chassis installation e install the shelf into the rack first then e install the Matrix N7 chassis into the rack 3 2 3 1 Installing the Shelf To install the shelf proceed as follows WARNING If the rack is not secured to the floor it is recommended that you install the chassis in the bottom half of the rack This helps prevent the rack from being top heavy ADVERTENCIA Si el rack no esta asegurado al piso es recomendable que instales el chasis en la parte de abajo del rack Esto ayuda a prevenir que el rack este demasiado pesado en la parte superior WARNHINWEIS Falls das Rack nicht mit Schrauben am Boden gesichert wird sollte das Chassis in der unteren Halfte des Racks installiert werden um ein kippen des Racks zu vermeiden 1 Keeping the above Caution note in mind locate the position on the rack where you will install the shelf The chassis requires 77 47 centimeters 30 5 inches of vertical spacing 2 Align the four holes in the ears of the shelf with those in the rack see Figu
2. entera 9033851 04 Nitworks that Know ELECTRICAL HAZARD Only qualified personnel should perform installation procedures RIESGO ELECTRICO Solamente personal calificado debe realizar procedimientos de instalacion ELEKTRISCHER GEFAHRENHINWEIS Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden NOTICE Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made The hardware firmware or software described in this document is subject to change without notice IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS DOCUMENT WEB SITE OR THE INFORMATION CONTAINED IN THEM EVEN IF ENTERASYS NETWORKS HAS BEEN ADVISED OF KNEW OF OR SHOULD HAVE KNOWN OF THE POSSIBILITY OF SUCH DAMAGES Enterasys Networks Inc 50 Minuteman Road Andover MA 01810 2004 Enterasys Networks Inc All rights reserved Part Number 9033851 04 August 2004 ENTERASYS NETWORKS ENTERASYS MATRIX LANVIEW MATRIX NETSIGHT WEBVIEW and any logos associated therewith are trademarks or registered trademarks of Enterasys Networks Inc in the United States and
3. 5 If you are installing a second power supply remove the blank plate from the second power supply slot PS2 keep the blank plate in the event you need to remove the power supply and repeat steps 1 4 Matrix N7 Chassis Setup 3 11 Setting Up the Matrix N7 Chassis Figure 3 7 Installing the Power Supply Module s Mandatory power supply installed in slot PS1 Slotted screw Power supply handle Blank plate covering slot PS2 Card guides NOTE To install the modules refer to the module installation guide for the installation instructions Before you power up the Matrix N7 chassis it is recommended that you complete the installation of the modules in the chassis After completing the power supply and module installations the Matrix N7 chassis is ready to be powered up Proceed to Section 3 3 for instructions to power up the chassis 3 2 5 Removing a Power Supply To remove a 7C203 1 power supply refer to Figure 3 8 and proceed as follows 1 Attach the anti static wrist strap as described in Section 3 2 3 3 before handling the power supply module CAUTION Always set the 0 1 power switch to 0 before removing a power supply from the chassis 2 Set the power supply O I Power switch to 0 3 12 Matrix N7 Chassis Setup Setting Up the Matrix N7 Chassis Unplug the power cords from each dedicated 15A 120 Vac outlet Unplug the power cord from the ac power connectors of the power su
4. PS1 LEDs PS2 LEDs POWER FAN POWER FAN 1 ON OFF Green Red Red 2 OFF ON Red Amber Green 3 ON Out of chassis Green Off Off 4 Out of chassis ON Off Green Green 5 ON ON lt 50 Green Green Green 6 ON ON gt 50 Amber Green Amber Green Installation Requirements and Guidelines 2 3 LANVIEW LEDs 2 3 2 Fan Tray LED Refer to Figure 2 2 for the location of the fan tray LED Table 2 2 describes the different states of the fan tray LED Figure 2 2 Fan Tray LED Fan tray LED Table 2 2 Fan Tray LED States and Their Definitions LED Color Status Green All fans are operating normally Red One or more fan failures have occurred NOTE When the Matrix N7 is first powered up the Fan Tray LED will display red briefly until the fans are operating at the proper speed 2 4 Installation Requirements and Guidelines 3 Matrix N7 Chassis Setup This chapter contains instructions on setting up the Matrix N7 chassis Equipment needed e Phillips screwdriver e Flat blade screwdriver RIESGO ELECTRICO Nada mas personal capacitado debe de instalar o darle servicio a esta unida ELEKTRISCHER GEFAHRENHINWEIS Installationen oder Servicearbeiten sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden f ELECTRICAL HAZARD Only qualified personnel should install or service this unit A Phillips screwdriver is needed to install the unit in a 48 26 centimeter 19 inch equipm
5. how to attach cable segments to the modules and how to configure the modules using Local Management after installation is complete The specifications for modules are included in each manual Each manual in this set assumes that the qualified personnel installing the module has a general working knowledge of data communications networks and their physical layer components Manuals can be accessed on the World Wide Web using the following URL http www enterasys com support manuals DOCUMENT CONVENTIONS The following conventions are used in this guide NOTE Calls the reader s attention to any item of information that may be of special importance ACHTUNG Verwei t auf wichtige Informationen zum Schutz gegen Besch digungen WARNING Warns against an action that could result in personal injury or death ADVERTENCIA Advierte contra una acci n que pudiera resultar en lesi n corporal o la CAUTION Contains information essential to avoid damage to the equipment CAUTELA Contiene informaci n esencial para prevenir da ar el equipo C muerte WARNHINWEIS Warnung vor Handlungen die zu Verletzung von Personen oder gar Todesfallen f hren k nnen xiv About This Guide Document Conventions ELECTRICAL HAZARD Warns against an action that could result in personal injury or death due to an electrical hazard RIESGO ELECTRICO Advierte contra una acci n que pudiera resultar en lesi n corporal o la muerte debido a un
6. Armenia Azerbaijan Belarus Bulgaria Cambodia Cuba Estonia Georgia Iraq Kazakhstan Kyrgyzstan Laos Latvia Libya Lithuania Moldova North Korea the People s Republic of China Romania Russia Rwanda Tajikistan Turkmenistan Ukraine Uzbekistan Vietnam or such other countries as may be designated by the United States Government ii export to Country Groups D 1 or E 2 as defined herein the direct product of the Program or the technology if such foreign produced direct product is subject to national security controls as identified on the U S Commerce Control List or iii if the direct product of the technology is a complete plant or any major component of a plant export to Country Groups D 1 or E 2 the direct product of the plant or a major component thereof if such foreign produced direct product is subject to national security controls as identified on the U S Commerce Control List or is subject to State Department controls under the U S Munitions List 5 UNITED STATES GOVERNMENT RESTRICTED RIGHTS The enclosed Program i was developed solely at private expense ii contains restricted computer software submitted with restricted rights in accordance with section 52 227 19 a through d of the Commercial Computer Software Restricted Rights Clause and its successors and iii in all respects is proprietary data belonging to Enterasys and or its suppliers For Department of Defense units the Program is considered comm
7. To send comments or suggestions concerning this document to the Technical Writing Department techwriting enterasys com To expedite your message please type techwriting in the subject line and include the document Part Number in the email message Before contacting Enterasys Networks for technical support have the following information ready e Your Enterasys Networks service contract number e A description of the failure e A description of any action s already taken to resolve the problem eg changing mode switches rebooting the unit etc e The serial and revision numbers of all involved Enterasys Networks products in the network e A description of your network environment layout cable type etc e Network load and frame size at the time of trouble if known e The device history i e have you returned the device before is this a recurring problem etc e Any previous Return Material Authorization RMA numbers Introduction 1 5 Getting Help 1 6 Introduction 2 Installation Requirements and Guidelines This chapter describes the following e Site guidelines that must be met before installing a Matrix N7 chassis into a rack or cabinet e Matrix N7 chassis configuration guidelines e Operating specifications for the Matrix N7 chassis enclosure and power supply modules ELECTRICAL HAZARD Only qualified personnel should perform installation procedures RIESGO ELECTRICO Solamente personal califi
8. and proceed as follows 1 Unpack the power supply by removing it from the shipping box and sliding the two foam end caps off the unit Save the shipping box and materials in the event the unit must be reshipped 2 Remove the power supply from its protective plastic bag Save the shipping box and materials in the event the unit must be reshipped 3 Examine the power supply carefully checking for damage If any damage is noted DO NOT install the power supply Contact Enterasys Networks immediately 4 Slide the power supply into the slot labeled PS1 as follows a Hold the power supply by placing one hand on the handle located on the front panel and using the other hand to support the power supply b Holding the power supply right side up align the power supply with the plastic guides on the bottom of the opening CAUTION Forcing a misaligned power supply into place can damage the power supply and or the chassis backplane c With the power supply properly inserted into the opening carefully slide the supply forward until it is connected to the backplane The front panel should be flush with the face of the Matrix N7 chassis If significant resistance is encountered before the front panel is flush remove and reinsert the power supply Do not force the power supply into place d Secure the power supply to the chassis by using a large flat blade screwdriver to turn the large screw and lock the power supply in place
9. den folgenden Richtlinien UL 60950 CSA C22 2 No 60950 73 23 EEC EN 60950 IEC 60950 ELECTROMAGNETIC COMPATIBILITY EMC This product complies with the following 47 CFR Parts 2 and 15 CSA C108 8 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 AS NZS CISPR 22 VCCI V 3 COMPATIBILIDAD ELECTROMAGNETICA EMC Este producto de Enterasys cumple con lo siguiente 47 CFR Partes 2 y 15 CSA C108 8 89 336 EEC EN 55022 EN 55024 EN 61000 3 2 EN 61000 3 3 AS NZS CISPR 22 VCCI V 3 ELEKTRO MAGNETISCHE KOMPATIBILITAT EMC Dieses Produkt entspricht den folgenden Richtlinien 47 CFR Parts 2 and 15 CSA C108 8 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 AS NZS CISPR 22 VCCI V 3 VCCI NOTICE This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions CORB m E ERMA VCCI DH BEE EE CT CORREA CHT S ER WHER AACTCEMHVET COPS LE SEDBRANSCLMSVES BSMI EMC STATEMENT TAIWAN This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures SARA ie PRN SNeon CEERI EARS oe B RST TEEPA SAABSREKE EER SERA SES DECLARATION OF CONFORMITY Applicati
10. individual power supply status and overall chassis redundancy status Refer to Chapter 2 Installation Requirements and Guidelines for a full explanation of the power supply LEDs and their definitions Introduction 1 3 Features Power Supply Status via Management The Matrix N7 chassis power supplies report information to the DFE modules installed in the chassis regarding their present operating status as well as the fan tray status This information includes the following e Power Supply ID PS1 PS2 e Power Supply Status normal fault not installed e Power Supply Redundancy indication redundant not available e Fan Status normal fault Refer to the module specific Configuration User s Guide for instructions on how to access power supply status information via Local Management Auto Ranging Power Supplies The Matrix N7 chassis power supplies automatically adjust to the input voltage and frequency which allows for an input voltage of 100 to 220 Vac and a frequency between 50 and 60 Hz See the operating specifications in Appendix A No additional adjustments are necessary For installations in North America two 15 A power cords are required See Section 3 3 for more details Power Supply Replacement To reduce network downtime a power supply may be removed after it has been powered down When two power supplies are installed this allows the removal of one power supply without powering down the chassis and interrupting ne
11. other countries All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies Documentation URL http www enterasys com support manuals Documentacion URL http www enterasys com support manuals Dokumentation http www enterasys com support manuals REGULATORY COMPLIANCE INFORMATION FEDERAL COMMUNICATIONS COMMISSION FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment uses generates and can radiate radio frequency energy and if not installed in accordance with the operator s manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void
12. rack 5 Open the top of the shipping bag covering the unit then pull the bag down around the skid 6 Remove and save the accessory package any other documents and cable from the top of the styrofoam cap The accessory package contains the following e Electrostatic Discharge ESD wrist strap e Installation Documentation e Rubber feet and screw assemblies e Cable management bar and associated hardware 7 Lift and remove the styrofoam cap from the top of the chassis Save for reshipping if necessary 8 Remove and save the eight screws fastening left and right shipping brackets to the chassis and the skid Remove and save the brackets and also the foam sheets which are between the chassis and the brackets 9 Lift and remove the chassis from the skid 10 Save the plastic bag and skid for future reshipment if necessary NOTE To reship the chassis refer to Figure 3 1 and perform each step in reverse and in the reverse order Ensure that all shipping brackets are used including the one that also serves as the shelf rear shipping bracket 3 2 Matrix N7 Chassis Setup Unpacking the Matrix N7 Chassis Unpacking the Matrix N7 Chassis Figure 3 1 Matrix N7 Chassis Setup 3 3 Setting Up the Matrix N7 Chassis 3 2 SETTING UP THE MATRIX N7 CHASSIS The following sections describe the procedures that must be followed to complete the installation of the Matrix N7 chassis 3 2 1 Order of Inst
13. riesgo el ctrico ELEKTRISCHER GEFAHRENHINWEIS Warnung vor s mtlichen Handlungen die zu Verletzung von Personen oder Todesfallen hervorgerufen durch elektrische Spannung f hren k nnen About This Guide XV Document Conventions xvi About This Guide 1 Introduction This chapter provides an overview of the Matrix N7 chassis and its features Also covered in this chapter are the instructions on how to obtain additional help from Enterasys Networks if needed 1 1 OVERVIEW The Matrix N7 chassis design provides seven slots for a new advanced generation of modules the Matrix DFE series modules All DFE modules installed in the N7 chassis operate as a system with a single IP address The Matrix N7 chassis e uses a distributed switching architecture e allows hot swapping of the DFE modules e supports redundant power supplies and e can be installed as a freestanding unit or installed into a standard 48 26 centimeter 19 inch rack All chassis components power supplies fan tray and modules are installed from the front of the chassis for ease of maintenance All LED indicators are observable from the front of the chassis to aid in monitoring network operational status and performing maintenance Figure 1 1 illustrates the Matrix N7 chassis equipped with two 1600 Watt 6C207 3 redundant power supplies Introduction 1 1 Overview Chassis 7C107 Fan tray 6C407 Module slots 7 total Re
14. the installation site must be maintained between 5 and 40 C 41 to 104 F Temperature changes must be maintained within 10 C 18 F per hour 2 2 CONFIGURATION GUIDELINES The Matrix N7 chassis has seven slots that accept DFE modules The slots are numbered 1 to 7 beginning with the leftmost slot There are two slots near the bottom of the chassis that are strictly for power supplies These slots are labeled PS1 and PS2 The DFE modules for the Matrix N7 chassis are equipped with a firmware based management tool which provides the capability to configure one or more DFE modules and access chassis power supply and fan tray information 2 3 LANVIEW LEDs The following sections describe the LANVIEW LED indications for the following e 6C207 3 power supply module e Fan tray unit 2 3 1 Power Supply LEDs There are two LEDs on the power supply Refer to Figure 2 1 for the location of the power supply LEDs Table 2 1 describes the different states of the power supply LEDs under six different conditions The power supplies are installed in chassis slots PS1 and PS2 in the front bottom part of the chassis 2 2 Installation Requirements and Guidelines LANVIEW LEDs Figure 2 1 6C207 3 Power Supply LEDs LINE 2 100 125V 12A 200 240V 6A 50 60Hz LINE 1 100 125V 10A 200 240V 5A 50 60Hz POWER LED FAN LED Table 2 1 Power Supply PS LED Status Definitions Condition PS1 PS2 Load
15. the user s authority to operate the equipment INDUSTRY CANADA NOTICE This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada CLASS A ITE NOTICE WARNING This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures CLASE A AVISO DE ITE ADVERTENCIA Este es un producto de Clase A En un ambiente dom stico este producto puede causar interferencia de radio en cuyo caso puede ser requerido tomar medidas adecuadas KLASSE A ITE ANMERKUNG ACHTUNG Dieses Produkt z hlt zur Klasse A Industriebereich In Wohnbereichen kann es hierdurch zu Funkst rungen kommen daher sollten angemessene Vorkehrungen zum Schutz getroffen werden PRODUCT SAFETY This product complies with the following UL 60950 CSA C22 2 No 60950 73 23 EEC EN 60950 IEC 60950 SEGURIDAD DEL PRODUCTO El producto de Enterasys cumple con lo siguiente UL 60950 CSA C22 2 No 60950 73 23 EEC EN 60950 TEC 60950 PRODUKTSICHERHEIT Dieses Produkt entspricht
16. T RIGHTS You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and accordingly You hereby agree to maintain complete books records and accounts showing i license fees due and paid and ii the use copying and deployment of the Program You also grant to Enterasys and its authorized representatives upon reasonable notice the right to audit and examine during Your normal business hours Your books records accounts and hardware devices upon which the Program may be deployed to verify compliance with this Agreement including the verification of the license fees due and paid Enterasys and the use copying and deployment of the Program Enterasys right of examination shall be exercised reasonably in good faith and in a manner calculated to not unreasonably interfere with Your business In the event such audit discovers non compliance with this Agreement including copies of the Program made used or deployed in breach of this Agreement You shall promptly pay to Enterasys the appropriate license fees Enterasys reserves the right to be exercised in its sole discretion and without prior notice to terminate this license effective immediately for failure to comply with this Agreement Upon any such termination You shall immediately cease all use of the Program and shall return to Enterasys the Program and all copies of the Program 9 OWNERSHIP This is a license agreement and n
17. allation Once a suitable site has been chosen the Matrix N7 chassis can be installed as a freestanding or rack mounted unit It is recommended that the Matrix N7 chassis installation proceed in the following order 1 Install the rubber feet for freestanding installation and cable management bar Section 3 2 2 2 Mount the chassis to a 48 26 centimeter 19 inch rack or other secure location Section 3 2 3 3 Attach the Electrostatic Discharge wrist strap Section 3 2 3 3 4 Install the power supply module s Section 3 2 4 3 2 2 Installing the Rubber Feet and Cable Management Bar bar may cause damage to the chassis CAUTION Using longer screws than the ones packaged with the cable management If you are installing the Matrix N7 chassis as a freestanding device start with Section 3 2 2 1 to install the rubber feet To install the chassis in a rack rubber feet are not needed Therefore start with Section 3 2 2 2 to install the cable management bar NOTE Before installing the rubber feet and cable management bar place the chassis on its back on a sturdy flat surface to have access to the bottom of the chassis 3 4 Matrix N7 Chassis Setup Setting Up the Matrix N7 Chassis 3 2 2 1 Installing the Rubber Feet To install the rubber feet see Figure 3 2 and proceed as follows 1 Place the chassis on a sturdy flat surface to access the bottom of the chassis 2 Remove the four rubber foot screw assemblies from
18. cado debe realizar procedimientos de instalacion ELEKTRISCHER GEFAHRENHINWEIS Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden 2 1 SITE GUIDELINES The following guidelines must be followed when a site is selected for the Matrix N7 chassis If the guidelines are not followed unsatisfactory network performance may result To allow proper cooling within the rack there must be 7 62 centimeters 3 inches of clearance above the unit and 5 08 centimeters 2 inches of clearance on either side of the unit e To install the Matrix N7 chassis as a freestanding unit on a shelving unit the shelf must be able to support 80 kilograms 176 pounds of static weight e To install the Matrix N7 chassis as a rack mounted unit care must be taken to ensure that the rack used will support the unit and that the rack remains stable e The 6C207 3 ac power supplies for the Matrix N7 7C107 chassis require two three pronged power receptacles capable of delivering the current and voltage specified in Section A 2 Two ac outlets on independently fused circuits are required for each 6C207 3 and must be located within 182 centimeters 6 feet from the site The power cord used and type of outlet is dependent on the country In the United States two power cords with NEMA 5 15P plugs are provided with each 6C207 3 Installation Requirements and Guidelines 2 1 Configuration Guidelines e Ambient temperature at
19. d defines conventions used throughout this document Chapter 1 Introduction describes the features and capabilities of the Matrix N7 chassis and how to get help Chapter 2 Installation Requirements and Guidelines lists the installation site requirements that must be met before installing the Matrix N7 chassis in a cabinet or rack This chapter also includes configuration guidelines and operating specifications for the Matrix N7 enclosure and power supply modules Chapter 3 Matrix N7 Chassis Setup contains instructions for a standalone or rackmount installation of the Matrix N7 chassis It also provides instructions for installing the cable management bar installing the power supply modules removing and reinstalling the fan tray and powering up the Matrix N7 chassis Appendix A Specifications and Regulatory Compliance lists environmental and operating specifications for the Matrix N7 chassis and power supply modules About This Guide xiii Using the Matrix N7 7C 107 Chassis Series Manual Set USING THE MATRIX N7 70107 CHASSIS SERIES MANUAL SET Separate manuals have been developed for the 7xxxxx series DFE modules that can be installed in the Matrix N7 chassis NOTE The Matrix N7 chassis supports the DFE Distributed Forwarding Engine 7xxxxx series of modules and does not support the older 6x1xx 6x2xx and 6x3xx series of modules The 7xxxxx series manuals explain how to install the modules into the Matrix N7 chassis
20. dundant power supplies 6C207 3 2 1 2 Introduction Features 1 2 FEATURES The following provides an overview of the chassis features NOTE The Matrix N7 chassis supports the DFE Distributed Forwarding Engine 7XXXxx series of modules and does not support the older 6x1xx 6x2xx and 6x3xx series of modules Matrix N7 Chassis Modules The Matrix N7 chassis has seven slots for the new Matrix DFE series of modules Redundant Power Supplies The Matrix N7 chassis supports two 6C207 3 power supplies that reside in the lower section of the chassis in slots labeled PS1 and PS2 The second power supply provides redundancy and load sharing 6C207 3 The 6C207 3 is a 1600 Watt power supply which has two front panel ac input power connectors The type of power cords shipped with the unit is country dependent Each power cord must be plugged into an independent power circuit NOTE Both power cords must be connected to the 6C207 3 for it to operate and connected to two independent ac power sources to handle the input power requirements The 6C207 3 is capable of load sharing 50 5 of the Matrix N7 chassis power load If one power supply fails the other power supply supports the entire load of the chassis without interruption to network traffic Refer to Section 2 1 for power outlet requirements Power Supply LANVIEW LEDs Each power supply comes equipped with LANVIEW LEDs for at a glance diagnostics that indicate
21. e E 3 10 lngtalling the Power e TT ses css susnendimenrrrendenenenmentisente 3 12 Removing a Power Supply from a Powered Up Chassis eenseeeseeeereereeere eerren 3 13 Connecting the 15 Amp AC Power Cords to the 60207 3 ssssssssrnnsseernrenrsrrnseerrnne 3 14 PDO Ce lied ge TI ea 3 16 Remstalling the Fearn Tray chase scccto pect ediomeceatentind i lt vcbene eeeHiawia anae a N 3 17 Figures xi Tables Table 2 1 2 2 xii Power Supply PS LED Status Definitions Fan Tray LED States and Their Definitions Tables About This Guide Welcome to the Enterasys Networks Matrix N7 7C107 Chassis Installation Guide This guide lists the features and options of the Matrix N7 7C107 chassis and explains how to remove and reinstall its fan tray install the cable management bar and power supplies USING THIS GUIDE Read through this guide completely to familiarize yourself with its contents and to gain an understanding of the features and capabilities of the Matrix N7 7C107 chassis A general working knowledge of data communications networks is helpful when setting up the Matrix N7 7C107 chassis NOTE In this guide the Matrix N7 7C107 chassis is also referred to as the Matrix N7 chassis STRUCTURE OF THIS GUIDE This guide is organized as follows This preface provides preliminary information to help you use this guide and a brief summary of each chapter It also discusses the Matrix N7 Series manual set an
22. ent rack and to install the cable management bar A large flat blade screwdriver is needed to secure the power supplies and to remove and reinstall the fan tray Refer to Chapter 2 for the guidelines that must be followed to install the Matrix N7 chassis 3 1 UNPACKING THE MATRIX N7 CHASSIS NOTE Unpack the Matrix N7 chassis components only as needed Leave the components in their respective shipping cartons until you are ready to install that component Save all shipping materials in the event that the chassis has to be repacked The Matrix N7 chassis is packed and shipped on a skid Before unpacking the chassis examine the outside packaging for obvious damage To unpack the Matrix N7 chassis refer to Figure 3 1 which includes numbers that correspond to the steps below and proceed as follows 1 Cut the two shipping straps fastening the corrugated box to the skid 2 Lift and remove the box off the skid 3 Remove and save four screws fastening the rear shipping bracket shelf to the rear of the chassis Matrix N7 Chassis Setup 3 1 Unpacking the Matrix N7 Chassis NOTE The rear shipping bracket is also the shelf used to mount the chassis in an equipment rack Instructions for installing the shelf into the rack are provided in Section 3 2 3 1 4 Remove and save the four screws fastening the rear shipping bracket shelf to the skid Remove the rear shipping bracket shelf from the skid and set aside for later installation in the
23. er by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and will not be construed as a waiver of any subsequent breach of such term or condition Enterasys failure to enforce a term upon Your breach of such term shall not be construed as a waiver of Your breach or prevent enforcement on any other occasion 13 SEVERABILITY In the event any provision of this Agreement is found to be invalid illegal or unenforceable the validity legality and enforceability of any of the remaining provisions shall not in any way be affected or impaired thereby and that provision shall be reformed construed and enforced to the maximum extent permissible Any such invalidity illegality or unenforceability in any jurisdiction shall not invalidate or render illegal or unenforceable such provision in any other jurisdiction 14 TERMINATION Enterasys may terminate this Agreement immediately upon Your breach of any of the terms and conditions of this Agreement Upon any such termination You shall immediately cease all use of the Program and shall return to Enterasys the Program and all copies of the Program Contents PR an then EE RH ABOUT THIS GUIDE Using This D nn annonce Ml Structure of This Guide Using the Matrix N7 7C107 Chassis 1 INTRODUCTION 1 1 IT EE E 1 2 Features vee 1 3 Genting EEN E 2 INSTALLATION REQUIREMENTS AND GUIDELINES 2 1 Site GUANO PT RE TN 2 1 22 Conugurato
24. ercial computer software in accordance with DFARS section 227 7202 3 and its successors and use duplication or disclosure by the Government is subject to restrictions set forth herein 6 DISCLAIMER OF WARRANTY EXCEPT FOR THOSE WARRANTIES EXPRESSLY PROVIDED TO YOU IN WRITING BY Enterasys Enterasys DISCLAIMS ALL WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY SATISFACTORY QUALITY FITNESS FOR A PARTICULAR PURPOSE TITLE AND NON INFRINGEMENT WITH RESPECT TO THE PROGRAM IF IMPLIED WARRANTIES MAY NOT BE DISCLAIMED BY APPLICABLE LAW THEN ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THIRTY 30 DAYS AFTER DELIVERY OF THE PROGRAM TO YOU 7 LIMITATION OF LIABILITY IN NO EVENT SHALL ENTERASYS OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OF BUSINESS INFORMATION SPECIAL INCIDENTAL CONSEQUENTIAL OR RELIANCE DAMAGES OR OTHER LOSS ARISING OUT OF THE USE OR INABILITY TO USE THE PROGRAM EVEN IF ENTERASYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES THIS FOREGOING LIMITATION SHALL APPLY REGARDLESS OF THE CAUSE OF ACTION UNDER WHICH DAMAGES ARE SOUGHT THE CUMULATIVE LIABILITY OF ENTERASYS TO YOU FOR ALL CLAIMS RELATING TO THE PROGRAM IN CONTRACT TORT OR OTHERWISE SHALL NOT EXCEED THE TOTAL AMOUNT OF FEES PAID TO ENTERASYS BY YOU FOR THE RIGHTS GRANTED HEREIN 8 AUDI
25. g and Reinstalling the Fan Tray Figure 3 11 Reinstalling the Fan Tray Slotted screw 2 Once the tray is in place tighten the two slotted screws to secure the tray to the Matrix N7 chassis Matrix N7 Chassis Setup 3 17 Removing and Reinstalling the Fan Tray 3 18 Matrix N7 Chassis Setup A Specifications and Regulatory Compliance This appendix provides operating specifications for the Matrix N7 7C107 chassis Enterasys Networks reserves the right to change the specifications at any time without notice A 1 PHYSICAL SPECIFICATIONS The physical specifications for the Matrix N7 7C107 chassis the 6C207 3 power supply module and the 6C407 fan tray module are as follows 7C107 Chassis Dimensions 77 47 H x 44 04 W x 36 83 D cm 30 5 H x 17 34 W x 14 5 D in Weight with factory installed fan tray 23 6 kg 52 0 Ib MTBF Predicted 404 872 hours 6C207 3 Power Supply Modules Dimensions 12 7 H x 21 0 W x 27 94 D cm 5 0 H x 8 27 W x 11 0 D in Weight 9 1 kg 20 0 Ib MTBF Predicted 200 000 hours 6C407 Fan Tray Dimensions 6 57 H x 43 64 W x 34 82 D cm 2 59H x 17 18 W x 13 71 D in Weight 2 3 kg 5 0 Ib MTBF Predicted 404 787 hours Specifications and Regulatory Compliance A 1 Power Supply Requirements A 2 POWER SUPPLY REQUIREMENTS The requirements for the 6C207 3 ac power supply modules are as follows Input Frequency 50 to 60 Hz Input Voltage Curre
26. ility company or other form of enterprise that directly or indirectly through one or more intermediaries controls or is controlled by or is under common control with the party specified This Agreement constitutes the entire understanding between the parties and supersedes all prior discussions representations understandings or agreements whether oral or in writing between the parties with respect to the subject matter of this Agreement The Program may be contained in firmware chips or other media BY INSTALLING OR OTHERWISE USING THE PROGRAM YOU REPRESENT THAT YOU ARE AUTHORIZED TO ACCEPT THESE TERMS ON BEHALF OF THE END USER IF THE END USER IS AN ENTITY ON WHOSE BEHALF YOU ARE AUTHORIZED TO ACT YOU AND YOUR SHALL BE DEEMED TO REFER TO SUCH ENTITY AND THAT YOU AGREE THAT YOU ARE BOUND BY THE TERMS OF THIS AGREEMENT WHICH INCLUDES AMONG OTHER PROVISIONS THE LICENSE THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED PRODUCT TO ENTERASYS OR YOUR DEALER IF ANY WITHIN TEN 10 DAYS FOLLOWING THE DATE OF RECEIPT FOR A FULL REFUND IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT CONTACT ENTERASYS NETWORKS LEGAL DEPARTMENT AT 978 684 1000 You and Enterasys agree as follows 1 LICENSE You have the non exclusive and non tra
27. n Cule Ssnan iaaa padeaedensanzytuesetocer eet nine cet Oe 25 LANVIEW LEDS e Si ai 2 3 1 Power Guppy LES enum linda E 2 3 2 Fan Tray WE Dic EE e 2 4 3 MATRIX N7 CHASSIS SETUP 3 1 Unpacking the Matrix N7 CHASSIS nrsniinimrircasiina iar ii Sc K Setting Up the Matrix N7 Chassis 8 4 3 2 1 Order of Installation 3 2 2 Installing the Rubber Fe i 3 2 3 Rack Mounting the Matrix N7 Chassis EA 3 2 4 Installing a Power Supply 3 1 3 25 Removing a Power Supply 312 33 Powering Up a Matrix N7 Chassis with Power Supplies 3 14 3 4 Removing and Reinstalling the Fan Tra 3 15 3 4 1 Removing the Fan Tray eee 3 15 3 4 2 Reinstalling the Fan Tray Contents ix x A 1 A 2 A 3 A 4 Contents Regulatory Compliance SPECIFICATIONS AND REGULATORY COMPLIANCE Physical Specifications Power Supply Requirements Environmental Requirements Figure 1 1 2 1 2 2 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 3 10 3 11 Page The Matrix N7 7C107 Chassis with Redundant Power Supplies n 1 2 0207 3 Power Supply LEDS nr murs teti rennes ven tant Eana a 2 3 SA E 2 4 Unpacking the Matrix N7 CHASSIS siiicar 3 3 Chassis Bottom Rubber Feet Placement 3 5 Installing the Cable Management BA siscccessuetiscscecsesececesmeetecice rece pccstemeeslecidion eetceeemeencions 3 6 UN E Renee erica ren lee 3 8 Rack Mounting tie Matie NS ChasSig ni anne is BEES 3 9 ESD Cope e Heh
28. nections Figure 3 9 Connecting the 15 Amp AC Power Cords to the 6C207 3 NEMA 5 15P 15 A power cords 4 AC power socket 2 each supply NOTE Power cords shown are for North America only 115 Vac 15 A power outlet Each outlet must be on a separate circuit 3 14 Matrix N7 Chassis Setup Removing and Reinstalling the Fan Tray 2 Plug each of the power cords into separate dedicated 15 A 115 Vac receptacles Set the O I Power switch on the front panel of each power supply to l 3 Ensure that the Power LED on each power supply is green 4 Ensure that all fans in the fan tray unit are operating properly when power is received from the power supply modules fan tray LED will be green For more information on the power supply LEDs Power and Fan refer to Section 2 3 If you experience any problems with this installation contact Enterasys Networks for assistance 3 4 REMOVING AND REINSTALLING THE FAN TRAY The Matrix N7 chassis is equipped at the factory with a removable fan tray that allows for easy periodic cleaning and or replacement if a problem occurs with fan operation A flat blade screwdriver is needed to remove and reinstall the fan tray To remove and reinstall the fan tray refer to Section 3 4 1 and Section 3 4 2 extended periods of time without the fan tray as the chassis will quickly overheat and cause damage CAUTION The fan tray is hot swappable However do not run the chassis fo
29. nsferable right to use only the one 1 copy of the Program provided in this package subject to the terms and conditions of this Agreement 2 RESTRICTIONS Except as otherwise authorized in writing by Enterasys You may not nor may You permit any third party to i Reverse engineer decompile disassemble or modify the Program in whole or in part including for reasons of error correction or interoperability except to the extent expressly permitted by applicable law and to the extent the parties shall not be permitted by that applicable law such rights are expressly excluded Information necessary to achieve interoperability or correct errors is available from Enterasys upon request and upon payment of Enterasys applicable fee ii Incorporate the Program in whole or in part in any other product or create derivative works based on the Program in whole or in part iii Publish disclose copy reproduce or transmit the Program in whole or in part iv Assign sell license sublicense rent lease encumber by way of security interest pledge or otherwise transfer the Program in whole or in part v Remove any copyright trademark proprietary rights disclaimer or warning notice included on or embedded in any part of the Program 3 APPLICABLE LAW This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws pro
30. nt 2 x 100 to 125 Vac 10 5 A 2 x 200 to 240 Vac 5 5 A Input Power 1600 W A3 ENVIRONMENTAL REQUIREMENTS Operating Temperature 5 C to 40 C 41 F to 104 F Storage Temperature 30 C to 73 C 22 F to 164 F Operating Relative Humidity 5 to 90 non condensing A 4 REGULATORY COMPLIANCE This equipment meets the following safety and electromagnetic compatibility EMC requirements Safety UL 60950 CSA C22 2 No 60950 73 23 EEC EN 60950 IEC 60950 Electromagnetic Compatibility EMC 47 CFR Parts 2 and 15 CSA C108 8 89 336 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 AS NZS CISPR 22 VCCI V 3 A 2 Specifications and Regulatory Compliance
31. on of Council Directive s Manufacturer s Name Manufacturer s Address European Representative Address Conformance to Directive s Product Standards Equipment Type Environment 89 336 EEC 73 23 EEC Enterasys Networks Inc 50 Minuteman Road Andover MA 01810 USA Enterasys Networks Ltd Nexus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England EC Directive 89 336 EEC EN 55022 EN 55024 EC Directive 73 23 EEC EN 60950 Networking Equipment for use in a Commercial or Light Industrial Environment Enterasys Networks Inc declares that the equipment packaged with this notice conforms to the above directives ENTERASYS NETWORKS INC FIRMWARE LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT CAREFULLY READ THIS LICENSE AGREEMENT This document is an agreement Agreement between the end user You and Enterasys Networks Inc on behalf of itself and its Affiliates as hereinafter defined Enterasys that sets forth Your rights and obligations with respect to the Enterasys software program firmware installed on the Enterasys product including any accompanying documentation hardware or media Program in the package and prevails over any additional conflicting or inconsistent terms and conditions appearing on any purchase order or other document submitted by You Affiliate means any person partnership corporation limited liab
32. ot an agreement for sale You acknowledge and agree that the Program constitutes trade secrets and or copyrighted material of Enterasys and or its suppliers You agree to implement reasonable security measures to protect such trade secrets and copyrighted material All right title and interest in and to the Program shall remain with Enterasys and or its suppliers All rights not specifically granted to You shall be reserved to Enterasys 10 ENFORCEMENT You acknowledge and agree that any breach of Sections 2 4 or 9 of this Agreement by You may cause Enterasys irreparable damage for which recovery of money damages would be inadequate and that Enterasys may be entitled to seek timely injunctive relief to protect Enterasys rights under this Agreement in addition to any and all remedies available at law 11 ASSIGNMENT You may not assign transfer or sublicense this Agreement or any of Your rights or obligations under this Agreement except that You may assign this Agreement to any person or entity which acquires substantially all of Your stock or assets Enterasys may assign this Agreement in its sole discretion This Agreement shall be binding upon and inure to the benefit of the parties their legal representatives permitted transferees successors and assigns as permitted by this Agreement Any attempted assignment transfer or sublicense in violation of the terms of this Agreement shall be void and a breach of this Agreement 12 WAIVER A waiv
33. pply Unscrew the captive slotted head screw to release the power supply from the chassis Aw E amp To remove the power supply from the chassis grasp the handle and pull the power supply straight out of the chassis then place it on an antistatic surface or in an antistatic bag for future use install a coverplate similar to in place of the removed power supply to contain EMI CAUTION If you plan to operate the chassis with only one power supply make sure to radiation Figure 3 8 Removing a Power Supply from a Powered Up Chassis Power switch AC power connector N7 chassis AC power cord Power supply Power supply handle 15A 120 Vac power outlet Captive slotted head screw Example of blank plate Matrix N7 Chassis Setup 3 13 Powering Up a Matrix N7 Chassis with Power Supplies 3 3 POWERING UP A MATRIX N7 CHASSIS WITH POWER SUPPLIES To power up a Matrix N7 chassis with ac power supplies refer to Figure 3 9 and proceed as follows NOTE If two power supplies are installed repeat the following procedure for each supply For redundancy using two 6C207 3 power supplies each of the four power cords from the two power supplies must be connected to dedicated 15 Ampere ac power circuits 1 Plug one end of each power cord supplied with the power supply into the ac power socket on the front panel of the power supplies See Figure 3 9 for the 6C207 3 power con
34. r any 3 4 1 Removing the Fan Tray To remove the fan tray refer to Figure 3 10 and proceed as follows 1 Locate the ESD wrist strap shipped with the Matrix N7 chassis Attach the ESD wrist strap to your wrist and plug the cable from the ESD wrist strap into the ESD grounding receptacle at the upper right corner of the chassis 2 Use the flat blade screwdriver to loosen the slotted screws located on either side of the fan tray 3 Slowly slide the fan tray out of its slot in the bottom of the chassis Matrix N7 Chassis Setup 3 15 Removing and Reinstalling the Fan Tray Figure 3 10 Removing the Fan Tray Slotted screw 2 3 4 2 Reinstalling the Fan Tray To reinstall the fan tray refer to Figure 3 11 and proceed as follows 1 Locate the ESD wrist strap shipped with the Matrix N7 chassis Attach the ESD wrist strap to your wrist and plug the cable from the ESD wrist strap into the ESD grounding receptacle at the upper right corner of the chassis 2 Hold the sides of the fan tray 3 Line up the rails on each side of the fan tray with the slot guides on the chassis CAUTION In the following step ensure that you do not force the fan tray into place as it may damage the unit 4 Slide the fan tray into the chassis until the faceplate of the tray is flush with the face of the Matrix N7 chassis If there is any strong resistance remove the fan tray and reinsert it 3 16 Matrix N7 Chassis Setup Removin
35. re 3 4 A then fasten the shelf to the rack using four of the screws supplied with the rack 3 After installing the shelf proceed to install the Matrix N7 chassis as described in Section 3 2 3 2 Matrix N7 Chassis Setup 3 7 Setting Up the Matrix N7 Chassis Figure 3 4 Shelf Installation 3 2 3 2 Installing the Matrix N7 Chassis CAUTION Read Chapter 2 before completing the following procedure to ensure that all installation guidelines are met To install the Matrix N7 chassis proceed as follows O WARNING To help prevent personal injury at least two people are required to lift the chassis into the rack ADVERTENCIA Para ayudar a prevenir alguna lesi n personal al menos dos personas son requeridas para levantar el chasis y meterlo al rack WARNHINWEIS Zum Schutz vor k rperlichen Sch den sollten sie mit min zwei Personen das Chassis in das Rack heben 1 Lift the chassis onto the shelf and slide it all the way into the rack Refer back to Figure 3 4 B 2 Use 10 screws 5 per side provided with the equipment rack to secure the chassis to the rack starting with the bottom holes and working toward the top of the chassis as shown in Figure 3 5 3 8 Matrix N7 Chassis Setup Setting Up the Matrix N7 Chassis SD Si E Rack mounting screws 5 per side Matrix N7 Chassis Setup 3 9 Setting Up the Matrix N7 Chassis 3 2 3 3 Attaching the Electrostatic Di
36. scharge Wrist Strap The Electrostatic Discharge ESD wrist strap must be attached before handling the power supplies fan tray and modules used in the Matrix N7 chassis In addition observe all precautions when handling these modules to prevent damage from electrostatic discharge Place the ESD wrist strap on your wrist and plug the other end into the grounding receptacle at the top right corner of the chassis shown in Figure 3 6 Figure 3 6 ESD Grounding Receptacle N7 3 2 4 Installing a Power Supply You must install at least one 7C203 1power supply in the Matrix N7 chassis One power supply provides sufficient power for a fully loaded chassis but a second power supply can be installed to provide a redundant load sharing power source When you receive your N7 chassis a cover plate will be in place over power supply slot PS2 When two power supplies are installed the load is evenly distributed If one power supply fails for any reason the second power supply assumes the load The power supplies must be installed in the two slots labeled PS1 and PS2 at the bottom of the chassis Figure 3 7 If you intend to install a single power supply it must be installed in the slot labeled PS1 in the chassis A large flat blade screwdriver is needed to install the power supplies 3 10 Matrix N7 Chassis Setup Setting Up the Matrix N7 Chassis To install the power supply into the Matrix N7 chassis refer to Figure 3 7
37. their plastic bag in the shipping box 3 Locate the four tapped holes in the four corners on the bottom of the chassis Figure 3 2 Chassis Bottom Rubber Feet Placement Bottom of chassis Tapped hole for rubber foot four places 4 Screw in and hand tighten each of the four rubber foot screw assemblies into the four tapped holes Then tighten with a Phillips screwdriver 5 After installing the rubber feet proceed to Section 3 2 2 2 to install the cable management bar Matrix N7 Chassis Setup 3 5 Setting Up the Matrix N7 Chassis 3 2 2 2 Installing the Cable Management Bar Cables can be attached along the cable management bar using cable ties to ensure that the cables are not accidentally loosened or disconnected from the chassis during operation To install the cable management bar see Figure 3 3 and proceed as follows 1 Remove the cable management bar from the shipping box Ensure that there are four screws inside the bag with the cable management bar 2 Line up the two holes on each side of the cable management bar with the four holes located on the bottom of the Matrix N7 chassis near the front of the chassis as shown in Figure 3 3 3 Use a Phillips screwdriver and the four screws supplied with the bar to fasten the cable management bar to the bottom of the chassis Figure 3 3 Installing the Cable Management Bar O em ap
38. twork traffic The Matrix N7 Chassis Cooling System The Matrix N7 chassis features a removable fan tray that is accessible from the front of the unit This unit is hot swappable which allows it to be replaced without powering down the chassis The fan tray has one LANVIEW LED located on the front of the unit This LED indicates the status of the fan tray normal fault not installed Refer to Chapter 2 for a full description of the fan tray LED states 1 4 Introduction Getting Help Standalone or Rack Mountable Chassis The Matrix N7 chassis can be installed as a freestanding unit on a shelf or table The Matrix N7 chassis can also be mounted into a standard 48 26 centimeter 19 inch equipment rack An equipment shelf is shipped with the chassis that you install prior to installing the chassis The Matrix N7 chassis can then be slid onto the shelf into place and then fastened to the chassis Refer to Section 2 1 for requirements on ventilation and cooling 1 3 GETTING HELP For additional support related to the modules or this document contact Enterasys Networks using one of the following methods World Wide Web http www enterasys com support Phone 603 332 9400 1 800 872 8440 toll free in U S and Canada For the Enterasys Networks Support toll free number in your country http www enterasys com support gtac all html Internet mail support enterasys com To expedite your message please type eth in the subject line
39. visions You accept the personal jurisdiction and venue of the Commonwealth of Massachusetts courts None of the 1980 United Nations Convention on Contracts for the International Sale of Goods the United Nations Convention on the Limitation Period in the International Sale of Goods and the Uniform Computer Information Transactions Act shall apply to this Agreement 4 EXPORT RESTRICTIONS You understand that Enterasys and its Affiliates are subject to regulation by agencies of the U S Government including the U S Department of Commerce which prohibit export or diversion of certain technical products to certain countries unless a license to export the Program is obtained from the U S Government or an exception from obtaining such license may be relied upon by the exporting party If the Program is exported from the United States pursuant to the License Exception CIV under the U S Export Administration Regulations You agree that You are a civil end user of the Program and agree that You will use the Program for civil end uses only and not for military purposes If the Program is exported from the United States pursuant to the License Exception TSR under the U S Export Administration Regulations in addition to the restriction on transfer set forth in Sections 1 or 2 of this Agreement You agree not to 1 reexport or release the Program the source code for the Program or technology to a national of a country in Country Groups D 1 or E 2 Albania