Home
Pelco FR8316 Satellite Radio User Manual
Contents
1. No action required Red on transmitter Incoming video signal is not present on the channel Video source is not powered on Check power connection to the video source Video source is not connected to the transmitter Check BNC connections Coaxial cable is defective Replace cable Continued on next page C2603M 6 06 Table A Troubleshooting with Front Panel Indicators Continued Indicator Color Possible Cause Corrective Action Video P resent LED Continued Red on receiver Incoming video signal is not present on the channel Optical signal is not being received from the trans mitter Optic Fault LED is also red Refer to the Optic Fault LED Receiver section in this table Video source is no powered on Check power connection to the video source Video source is no connected to the transmitter Coaxial cable connected to the transmitter is defective Check BNC connections Replace cable Optic Fault LED Transmitter Green Laser is operating No action required properly Flashing red Laser has shut down Transmitter is operating in Ensure that transmitter oper extreme environmental conditions for example operating temperature is below or above recom mended range as stated in the Specifications section ates according to operating conditions stated in the Specifications section and
2. or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Installation should be done only by qualified personnel and conform to all local codes Use only installation methods and materials capable of supporting four times the maximum specified load A CCC approved power cord must be used to power this equipment when used in China CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so C2603M 6 06 The product and or manual may bear the following marks A This symbol indicates that dangerous voltage constituting a risk of electric shock is present CAUTION Seman RISK OF ELECTRIC SHOCK A T
3. 59 348 1120 www pelco com 1 09001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
4. INSTALLATION FT8316 FR8316 Fiber Transmitter and Receiver Sixteen Channel Digitally Encoded Video C2603M 6 06 Contents Important Safety Instructions 2 0 2 n eee ee 4 Regulatory Notie St concciskmur eu nneaecoadueusiuenie sd r ikr Heder ETENEE bard 6 PRODUCE OVEIVIEW e ceses andis r poet edwadouedeu ENES n EEE hoped EDRI E 7 Description scier isrrrsirrerinnannkiri nrerin ESNE E EER ened tence eens 7 MOUGIS c 2 nme e ne E EE E E EO EE E SE 8 Optional ACCESSES iriran ccc cence ARNEE G 8 Front Panel crepie icone ie ropi etae suree TORETE EE ace 9 Front Panel FT8316 Transmitter 0 nuunuu nananana 9 Front Panel FR8316 Receiver n annaua aaa 10 Rear Panel orri vate eacetntes morera taeae E A ee aE a SA 11 IstallatioN s ennea E ES E EEr eae EEEn 12 Package Contents cccccocsss irosiis piire renn EEE OnE EE EEEN 12 MOUNTING reieer eera EEEn E EEEE A 12 Mounting the Transmitter Receiver intoaRack 0005 12 Mounting the Transmitter Receiver to a Wall 0 0000 000s 12 CONNECTIONS 20 5 ide aae A dash aa E E E E E EEES 13 Troubleshooting s anasan anunn a cence ene teen ene es 14 SPSCIMIGATIONS sienne nk er n EEn EA AEAEE E E ETEA aa 17 List of Illustrations 1 Sixteen Channel Video FT8316 Transmitter and FR8316 Receiver 7 2 Front Panel of FT8316 Transmitter 20 0 cece eee 9 3 Front Panel of FR8316 Receiver n unanunnaaaauauaaaaaanara
5. K and European 100 240 VAC 47 63 Hz input 12 VDC 24 W output FT8316 FR8316 Fiber Transmitter and Receiver Installation manual this manual MOUNTING The FT8316 transmitter FR8316 receiver can be mounted into a rack or can be used as a stand alone module As a stand alone module the unit can be placed on a desktop or can be mounted to a wall MOUNTING THE TRANSMITTER RECEIVER INTO A RACK The FT8316 transmitter FR8316 receiver can be installed into an RK5000 Series rack mount chassis which can be mounted into an industry standard 19 inch 48 26 cm equipment rack The RK5000 Series rack mount chassis includes the following models RK5000PS 3U and RK5000 3U Designed to accommodate fiber optic modules as follows The RKSO00PS 3U rack mount chassis provides 12 single width module slots and a power supply The RK5000 3U rack mount chassis provides 14 single width module slots a power supply is not included Power to the modules can be supplied using the optional external power supply EPS5000 120 For additional information refer to the RK5000PS 3U RK5000 3U Fiber Rack Mount Chassis Installation manual RK5000PS 5U Designed to accommodate Endura modules but can also accommodate fiber optic modules with the use of the appropriate adapter kit The RK5004 1UEXP adapter kit is required for installation of the FT8316 transmitter FR8316 receiver into the RK5000PS 5U chassis For information about the RK5000PS 5U cha
6. TION FOR STAND ALONE MODULE COAXIAL CABLE e COAXIAL c i gt CABLE g smitter FR8316 receiver connections FIBER OPTIC of CABLE i coaxial e CABLE e e _ COAXIAL CABLE Figure 5 FT8316 Transmitter FR8316 Receiver Connections C2603M 6 06 Troubleshooting LED indicators on the front panel of the FT8316 transmitter and FR8316 receiver refer to Figure 2 and to Figure 3 respectively allow you to monitor signal status laser status transmitter only and operating power Table A provides information about the front panel indicators and associated troubleshooting guidelines Table A Troubleshooting with Front Panel Indicators Indicator Color Possible Cause Corrective Action Power LED Pelco badge Blue Pelco logo lights Power is being applied to the module No action required Blue Pelco logo does not light Power is not being applied to the module Power connection is faulty Check power connection If module is rack mounted reseat module or power supply as necessary Power supply has failed Loss of power occurs due to tripped circuit breakers blown fuses or faulty electrical service Replace power supply Check circuit breakers fuses or electrical service as necessary Video Present LED Green Incoming video signal is present on the channel
7. conforme a la norme NMB 003 du Canada C2603M 6 06 Product Overview DESCRIPTION The FT8316 FR8316 fiber transmitter and receiver provide the ability to transmit up to 16 composite video channels over one optical fiber refer to Figure 1 SIXTEEN SIXTEEN VIDEO VIDEO INPUTS OUTPUTS FT8316 FR8316 E TRANSMITTER ONE RECEIVER FIBER Figure 1 Sixteen Channel Video FT8316 Transmitter and FR8316 Receiver Features of the FT8316 FR8316 fiber optic transmission system include the following 8 bit digitally encoded video for high quality multichannel video transmission over a single fiber Multimode fiber support for distances up to 1 km 0 6 mi Single mode fiber support for distances up to 26 km 16 1 mi Exceeds all requirements for the RS 250C Medium Haul Transmission specification Compatible with NTSC PAL and SECAM video standards Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for ambient operating temperature mechanical shock and vibration humidity with condensation high line low line voltage conditions and transient voltage protection NOTE Conformal coating is required for operation in environments with relative humidity above 95 condensing No performance adjustments required 12 VDC or 24 VAC power supply Stand alone and rack mountable modular design LED indicators for monitoring of signal status laser status and operating power The FT8316
8. e years on PMCL200 300 400 Series LCD monitors e Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications e Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty e Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specif
9. his symbol indicates that there are important DO NOT OPEN operating and maintenance instructions in the literature accompanying this unit C2603M 6 06 5 Regulatory Notices This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est
10. ic use or application made of the Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information Model and serial number 2 Date of shipment PO number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization n
11. m multimode fiber subtract 3 dB from the optical power budget t Maximum transmission distance is limited by fiber bandwidth Maximum transmission distance is based on attenuation of 0 5 dB km plus a 5 dB buffer for connector and splice losses For conformal coated models replace the first letter F in the model number with the letter C The conformal coated version of FT8316MSTR for example is CT8316MSTR For models with higher optical power budgets contact the factory gt lt This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment C2603M 6 06 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FR FT FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products e Three years on Genex Series products multiplexers server and keyboard e Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty e Thre
12. narran 10 4 Rear Panel of FT8316 Transmitter and FR8316 Receiver 0 0000 11 5 FT8316 Transmitter FR8316 Receiver Connections 00000 13 List of Tables A Troubleshooting with Front Panel Indicators 0 0 0 0 c cece eee 14 C2603M 6 06 3 Important Safety Instructions So oF ee MS Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions o not install near any heat sources such as radiators heat registers stoves or other pparatus including amplifiers that produce heat oa o Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the 0 P bsolete outlet otect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer
13. odulation Type Video Input FT8316 Video Output FR8316 Bandwidth Gain Crosstalk Differential Gain Differential Phase Tilt Signal to Noise Ratio GENERAL Operating Temperature Input Power Requirements LED Indicators Dimensions Unit Weight MECHANICAL Connectors Video Rack Power Alarm Stand Alone Power Fiber Optic C2603M 6 06 16 Pulse code modulation 8 bit resolution 1 0 Vp p 75 ohms NTSC PAL and SECAM 6 5 MHz Unity 50 dB typical at 3 58 MHz lt 1 lt 1 2 lt 1 gt 60 dB CCIR weighted 40 to 167 F 40 to 75 C 12 VDC or 24 VAC 900 mA Power Video Present per channel Optic Fault one LED for channels 1 8 one LED for channels 9 16 8 75 D x 4 68 W x 4 81 H 22 23 x 11 89 x 12 22 cm 4 b 1 81 kg BNC per channel 4 pin connector 2 pin connector screw terminal ST for multimode fiber ST or FC for single mode fiber OPTICAL POWER BUDGET AND TRANSMISSION DISTANCE NOTES Model No Optical Maximum Compatible Power Transmission Transmitter Receiver Wavelength Budget Distance Multimode 62 5 125 pm FT8316MSTR FR8316MSTR 1275 nm 18 dB t 1 km 0 6 mi 1300 nm Single Mode 9 125 pm FT8316SSTR FR8316SSTR 1275 nm 18 dB 26 km 16 1 miJ 1300 nm FT8316SFCR FR8316SFCR 1275 nm 18 dB 26 km 16 1 miJ8 1300 nm Optical power budget is 15 dB when operating temperature range is 40 to 0 C tWhen using 50 125 y
14. r kit that allows a 3 RU quadruple width fiber module to be used in RK5000PS 5U rack mount chassis 8 C2603M 6 06 FRONT PANEL The front panel of the FT8316 transmitter and FR8316 receiver provides LED indicators that a Ilow you to monitor signal status laser status transmitter only and operating power The following sections provide a view of the front panel of the transmitter and receiver FRONT PANEL FT8316 TRANSMITTER Figure 2 illustrates the front panel of the FT8316 transmitter Figure 2 Front Panel of FT8316 Transmitter VIDEO PRESENT LEDs 1 16 OPTIC FAULT LED laser status indicator channels 1 8 OPTIC FAULT LED laser status indicator channels 9 16 NOTE As indicated above the two Optic Fault LEDs operate independently of one another One Optic Fault LED indicates laser status for channels 1 8 the other Optic Fault LED indicates laser status for channels 9 16 4 POWER LED Pelco badge For detailed information about the front panel indicators refer to the Troubleshooting section C2603M 6 06 9 FRONT PANEL FR8316 RECEIVER Figure 3 illustrates the front panel of the FR8316 receiver Figure 3 Front Panel of FR8316 Receiver VIDEO PRESENT LEDs 1 16 OPTIC FAULT LED optical signal status indicator channels 1 8 OPTIC FAULT LED optical signal status indicator channels 9 16 NOTE As indicated above the two Optic Fa
15. ssis refer to the RK5000PS 5U Rack Mount Chassis Installation manual NOTE The FT8316 transmitter FR8316 receiver is a quadruple width fiber optic module that occupies four slots in the RKS5000PS 3U RK5000 3U and RKS5000PS 5U chassis MOUNTING THE TRANSMITTER RECEIVER TO A WALL The FT8316 transmitter FR8316 receiver can be mounted to a wall using the WM5004 3U wall mount kit which is designed for mounting of one quadruple width fiber optic module only For WM5004 3U wall mount instructions refer to the installation instructions provided with the kit C2603M 6 06 CONNECTIONS Connections to the FT8316 transmitter and FR8316 receiver are made on the rear panel of the modules and consist of the following Power connection NOTES used as as supply is us Class 2 and In extreme empera ure conditions it is recommended A 12 VDC or 24 VAC power supply can be used to power the transmitter receiver when and alone module A 12 VDC power supply is provided If a 24 VAC power ed the power supply must be a Listed Direct Plug In Power Unit marked as rated as 24 VAC 1 A minimum output that an industrial rated outdoor power supply such as the Pelco WCS1 4 power supply be used Fiber connection Video input connections Video output connections ransmitter only receiver only Figure 5 illustrates FT8316 tran POWER ALARM CONNECTION FOR RACK MOUNTED MODULE a lt gt POWER CONNEC
16. then cycle the power lf problem persists contact Product Support Laser has reached end of life Cycle the power If problem persists contact Product Support C2603M 6 06 Continued on next page Table A Troubleshooting with Front Panel Indicators Continued Indicator Color Meaning Possible Cause Corrective Action Optic Fault LED Receiver Green The optical signal is No action required being received from the transmitter Red The optical signal is Transmitter is not powered Check power connections not being received on Replace power supply if from the transmitter necessary Fiber optic cable is not Check fiber optic connected connections Fiber optic cable connectors Clean polish or replace fiber are dirty or are damaged optic cable connectors as necessary Fiber optic cable is Replace cable defective Optical dB losses in the Check for problems with the iber optic installation fiber optic installation for exceed the optical power example excessive dB budget specification stated losses in connectors splices in the Specifications patch panels cables section and so on Optical dB losses in the Contact Product Support iber optic installation meet he optical power budget specification stated in the Specifications section however the receiver may be defective 16 C2603M 6 06 Specifications VIDEO Number of Channels M
17. transmitter FR8316 receiver is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825 1 Edition 1 2 2001 08 C2603M 6 06 MODELS The FT8316 FR8316 fiber transmitter and receiver consist of the following series of models Multimode Models FT8316MSTR Sixteen channel fiber optic video transmitter multimode ST connector FR8316MSTR Sixteen channel fiber optic video receiver multimode ST connector Single Mode Models FT8316SSTR Sixteen channel fiber optic video transmitter single mode ST connector FR8316SSTR Sixteen channel fiber optic video receiver single mode ST connector FT8316SFCR Sixteen channel fiber optic video transmitter single mode FC connector FR8316SFCR Sixteen channel fiber optic video receiver single mode FC connector For conformal coated models replace the first letter F in the model number with the letter C The conformal coated version of FT8316MSTR for example is CT8316MSTR OPTIONAL ACCESSORIES The following optional accessories are available WM5004 3U Wall mount kit for quadruple width module RK5000 3U 19 inch rack mount chassis for 14 slots no power 3 RUs RK5000PS 3U 19 inch rack mount chassis for 12 slots with power 3 RUs EPS5000 120 External rack power supply 1 RU dual 120 W power outputs RK5001B 3U Blank filler panel single width RK5002B 3U Blank filler panel double width RK5004 1UEXP Adapte
18. ult LEDs operate independently of one another One Optic Fault LED indicates optical signal status for channels 1 8 the other Optic Fault LED indicates optical signal status for channels 9 16 O POWER LED Pelco badge For detailed information about the front panel indicators refer to the Troubleshooting section 10 C2603M 6 06 REAR PANEL Connections to the FT8316 transmitter and FR8316 receiver are made to the rear panel of the modules refer to Figure 4 Figure 4 Rear Panel of FT8316 Transmitter and FR8316 Receiver RACK POWER ALARM CONNECTOR 4 pin connector for power alarm connection of rack mounted module STAND ALONE POWER CONNECTOR 2 pin connector for power connection of stand alone module removable mating connector with screw terminals not shown BNC CONNECTORS 1 16 75 ohm analog video input FT8316 output FR8316 FIBER OPTIC CONNECTOR ST or FC dependent on FT8316 FR8316 model oo 8 86 For additional information about rear panel connections refer to the nstallation section C2603M 6 06 11 Installation PACKAGE CONTENTS The following items are supplied 1 l FT8316 transmitter or FR8316 receiver Regulated switching power supply with either of the following e Four plug adapters North American Australian U K and European 100 240 VAC 50 60 Hz input 12 VDC 25 W output or e Three power cords North American U
19. umber CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C2603M 6 06 Original version Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Pelco Copyright 2006 Pelco DLP is a registered trademark of Texas Instruments Inc All rights reserved PELCO Worldwide Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 5