Home

LG Electronics 42LM660S Flat Panel Television User Manual

image

Contents

1. SOLEUSA R 14 000 BTU Portable Air Conditioner 12 000 BTU Heat Pump Operating Instructions El Model No LX 140 2006 Soleus Air International Thank you for choosing a Soleus Air LX 140 Portable Air Conditioner amp Heat Pump This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner with Heat Pump technology For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location Date Purchased Serial Number located on back of unit IMPORTANT INSTRUCTIONS Before installing and using your portable air conditioner please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the unit by inserting or pulling out the power plug 6 Do not use an adapte
2. Press the A or Y to select your desired temperature setting The temperature on the LCD dis play on the remote control will increase or decrease accordingly Pressing the Vand A buttons simultane ously will change the temperature select between F and C SLEEP MODE See SLEEP MODE on page 11 SWING To turn on the exclusive WAVEFLO oscillation press the SWING button on the remote control Once you press SWING the louvers on the unit will oscillate up and down and back and forth The bottom left square of the remote control display will show icon when WAVEFLO oscillation SWING is selected TIMER To program the timer first press the T ON button Once T ON is pressed the auto on timer will blink in the bottom right rectangle of the remote control display Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn on The minutes will increase by 10 with each press of the MIN button and the hours will increase by 1 with each press of the HOUR button Press the T OFF button and the remote control display will flash the desired auto off timer Press the MIN and HOUR buttons to change the clock to the desired time for the unit to automatically turn off The timer is set when the auto off time stops flashing and the words ON and OFF are displayed next to the time CLOCK To set the clock on the remote control hold down either the MIN or HOUR button until the displ
3. Inc e Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Warranty Technical Support Customer Service Missing or Defective Parts Please Call 888 876 5387 Or Write To Soleus International Inc 9451 Telstar Ave El Monte CA 91731 USA www soleusair com 15
4. This shows that temperature selection 15 not available when the unit is in Fan or Dehumidifier mode Mode Selection Press the MODE Button repeatedly to cycle between the different modes Auto Air Conditioner Dehumidifier Fan only and Heater mode The upper left square on the Remote control dis play will light up showing which mode 15 selected In Air Conditioner mode the display will show COOLING in Heating mode the display will show HEAT in Dehumidifier mode the display will show DRY in Fan mode the display will show FAN and in Auto mode the display will show AUTO Fan Speed Press the FAN speed button to cycle through low medium and high fan speeds The dis play on the remote control will show LOW MED amp HIGH under the SPEED label on the remote con trol LCD display There is an additional auto speed setting that is enabled in only heating and cooling modes This speed is next setting after low when pressing the FAN speed button on the remote control The speeds will cycle through in this order High Medium Low Auto Each change in speed will be as sociated with a beep sound from the unit The remote control will not display AUTO under the speed label Once Auto fan speed is selected the unit will beep and there will not be a fan speed displayed on the remote control Temperature Setting When the unit is in Air Conditioner or Heating mode you can select your desired temperature
5. 80 F Sleep Mode This mode can only be selected when using the Remote control 1 To set Sleep mode make sure the unit 15 in Conditioner mode 2 Press the SLEEP Button on the remote control The 2 icon appears on the control panel display 3 When in SLEEP mode the fan will run on low to keep fan noise at a minimum 4 When in Air Conditioner mode the temperature setting will gradually increase to 2 F above the original set temperature for 6 hours After 6 hours the temperature setting will return to the set temperature 5 When in Heating mode the temperature setting will gradually decrease to 2 F below the original set tem perature for 6 hours After 6 hours the temperature setting will return to the set temperature 6 When in Dehumidifier mode the temperature will not change when Sleep mode is selected Compressor Indicator 0 icon will light up on the control panel display when compressor turns on The turn off when the compressor shuts off 1 icon will Emergency Condensate Holding Tank When the room temperature 1s low and the indoor humidity is high the air conditioner may not be able to evaporate some of the moisture fast enough When this happens the water will accumulate in an emergency condensate tank inside the unit Once the emergency condensate tank 1s full the unit will automatically shut off and E will appear on the control panel display To empty the cond
6. B 78 F HEATING CAPACITY e Noise level is measured at a DEHUMIDIFYING CAPACITY distance of 3 28 away from POWER the Font of the unit when the e Power consumption Is meas 115 V 60 HZ ured when the fan runs at the 12 12 AMP HEATING COOLING highest speed setting SOUND PRESSURE LEVEL 46 dB A e These specifications are for NET WEIGHT 89 Lbs reference only For actual data please refer to the rating label OPERATING COOLING 60 8 F 108 F on the back of the unit TEMPERATURE HEATING 23 F 89 6 F Ifthe environment temperature ASSEMBLED 17 7 W X32 9 H X 18 9 D is hi DIMENSIONS Is higher than the max operat PACKAGE 19 9 W X 34 5 H X 22 5 D Ing temperature or lower than air fems REFRIGERANT perature the air conditioner may not work properly PRODUCT DIAGRAM Louvers Signal Receptor e Back Filter Compartment Air Outlet Hose Drain Port Control Panel Casters Evaporator Air Intake Air Intake Hose Air Intake Cover Filter PARTS amp ASSEMBLY PARTS EXHAUST HOSE Hose Adapter Exhaust Hose Window Kit Adaptor WINDOW KIT ASSEMBLY amp INSTALLATION INSTALLATION When the unit is operating as an air conditioner heater or dehumidifier the unit draws in fresh outdoor air and exhausts hot air in AC or dehumidifier mode or cool air in Heat mode out of the room to complete the air exchange When the unit is opera
7. ON OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 14 M EII 8LD I IIIIII I I I I I II I I III W I ZWK II I lt I EE WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air LX 140 Portable Air Conditioner with Heat Pump technology to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal use Soleus International Inc will at its option either repair or replace it free of charge within a reasonable time after the unit 1s returned during the warranty period As acondition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional
8. ayed time flashes on the remote control display Change the minutes by pressing the MIN button and change the hours by pressing the HOUR button 13 A MAINTENANCE Note Make sure power 15 off and the power cord 15 not plugged into an electrical outlet prior to performing any maintenance on the unit Clean or replace filter If the air filter 1s blocked with a dust the airflow volume may reduce It is recommended to clean the filter once every two weeks or as needed 1 Remove the filter from the filter compartment on the back of the unit 2 Wash the air filter by immersing it gently into warm water with a neutral detergent Rinse the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it 15 thoroughly dried 4 If the filter 15 torn or unusable order a new filter by calling the customer service number on the watranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess water by unplugging the water drainage stop In the back of the unit located at the bottom 2 Unplug the unit 3 The unit should be stored In a cool dry place DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATI
9. ensate tank pull the drain plug at the bottom back of the unit You will need a small pan approximately 1 high to catch the water coming out of the condensate tank Once the condensate tank is drained the unit will begin working within a few minutes The emergency condensate tank is approximately 1 5 Liters of water Another option is to purchase a small hose from a hardware store that can fit around the 5 8 drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage It is not advised to use continuous drainage when the room temperature is higher than 90 F 11 eee OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL LCD DISPLAY MODE BUTTON POWER BUTTON FAN SPEED w gt gt TEMP SETTING SWING LOUVER OSCILLATION TIMER ON SLEEP BUTTON FER m d TIMER OFF HOUR SELECTER MINUTE SELECTER 12 REMOTE CONTROL OPERATING INSTRUCTIONS 1 2 3 4 5 6 7 8 Power On and Off Press the POWER I O button once to manually turn the unit on Press the Power button once more to turn the unit off When you press the POWER button the upper right square on the remote control LCD Display will light up When in Conditioner Heating and Auto mode the selected temperature will appear on the remote control display When the unit is in Fan mode and Dehumidifier mode you will see the icon instead of the set temperature
10. l be on the left side of the unit when you are facing the back of the unit Cover the right circular air intake using the exhaust intake cover After installing the hose remove the square air intake cover on the back of the unit and install the square air intake vent with removable washable filter Exhaust Hose installed onto circular air outlet on left side Exhaust cover installed over circular air intake on right side Air Intake Cover Air Intake Vent For Single Hose Window Kit Installation To install the window kit follow the same directions on page 6 for dual hose installation but instead of using the dual hose window kit panel use the single hose panel pictured below Single Hose Window Kit Panel CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS CONTROL PANEL amp MULTI COLOR DISPLAY CONTROL PANEL TEMP amp TIMER SELECTION POWER BUTTON ND C Tola MODE BUTTON TIMER BUTTONS TEMP SELECT FAN SPEED BUTTON MULTI COLOR DISPLAY AUTO AIC DEHUM FAN HEAT TIMER ON TIMER OFF FAN SPEED TEMPERATURE AND TIMER INDICATOR OSCILLATION ON OFF COMPRESSOR ON OFF BUCKET FULL SLEEP MODE ON OFF OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS Refer to the images on page 8 1 Power On and Press the POWER button once to manually turn the unit on Press the POWER button once more to turn the unit off 2 Mode Selection Press the MODE Button repeatedly to cycle betwee
11. mprove the cooling efficiency NOTE When the unit is running on cooling mode the exhaust hoses are required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hoses and window kit properly see pages 6 amp 7 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button on the control panel 4 Press the MODE button until appears on the control panel display NOTE The unit operates at low fan speed during dehumidifier mode The unit cools room slightly during the dehumidification Keep the windows and doors closed to aid the effectiveness of the unit in removing the moisture from the room NOTE When the unit is running on dehumidifier mode the exhaust hoses are required and must be vented outside using the supplied window kit NOTE The unit will not perform in dehumidifier mode when the room temperature 1s lower than 61F Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel 3 Press the MODE button until icon appears on the control panel display 4 Select the fan speed by pressing the FAN button 5 To circulate more air press the SWING button on the remote control The louvers will oscillate in our exclusive WAVEFLO pattern back and forth and up and down spreading more air throughout the room NOTE It is not necessary for e
12. n the different modes Auto mode Air Conditioner Dehumidifier Fan only and Heater 3 Fan Speed Control Press the FAN SPEED Button to cycle through the different fan speeds High Medium and low The fan speed can be visually distinguished by the speed of the digital air segments progressing out from windmill fan image on the Multi color display There is an additional auto speed setting that is enabled in only heating and cooling modes This speed is next setting after low when press ing the speed control button The speeds will cycle through in this order Low Medium High Auto Each change in speed will be associated with a sound from the unit 4 Temperature Select the desired temperature by pressing either Y or key when using the unit in cooling or heating mode The temperature indicator flashes to display the desired temperature setting After the temperature 15 set the unit will display this temperature setting until it is changed by the user The Multi color display shows temperature in Celsius or Fahrenheit Press the F C button on the control panel to select the desired temperature setting 5 Timer To program the timer press the TIMER ON button until the display shows a flashing s Press Y buttons to change clock to desired time for the unit to automatically turn on 0 Press the TIMER OFF button and the display on the unit will flash O Press the or V butt
13. ocation near a grounded electrical outlet and a suitable window or door Remove packaging and locate components figure a 2 Remove the outlet covers from the back of the unit by screwing them counter clockwise then lifting up figure b 3 Pull out one end of the exhaust hose then screw on the adapter clockwise Repeat on other exhaust hose figure c 4 Pull out the opposite end of the exhaust hose then screw on the window kit adapter clockwise Repeat on other exhaust hose figure d 5 Mount the exhaust hoses onto the back of the unit figure e 6 Open the window or door and adjust the length of the window kit to fit the opening figure f If necessary mark the kit and cut down one end to properly fit the opening figures g amp h 7 Attach the window kit adapters to the window kit figure i Close the window or door tightly figure j Your Portable Air Conditioner is now ready to cool NOTE When using the venting system keep the exhaust hose as short and straight as possible The exhaust hose can be shortened but it is not recommended to increase the length of the exhaust hose Do not use an extension cord with your portable air conditioner SINGLE HOSE EXHAUST amp WINDOW KIT INSTALLATION When you want quick spot cooling install the LX 140 using the single hose window kit installation For Single Hose Installation Install only the left exhaust hose over the circular air outlet this outlet wil
14. ons to change the clock to the desired time for the unit to automatically turn off The TIMER OFF indicator will flash for 3 seconds to activate the times you programmed NOTE The timer will also remember your settings when it is set If you set the timer while in Air Condition ing mode the timer will automatically turn the unit on and off in air conditioning mode according to the de sired programmed times The timer will also remember the temperature settings fan speed and oscillation set ting The timer works when the unit is in Air Conditioner mode Heating mode Dehumidifier mode Fan mode and Auto mode OPERATING THE UNIT USING THE CONTROL PANEL Air Conditioner Mode 1 Install the exhaust hoses and window kit properly see pages 6 amp 7 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel 25 4 Press the Mode button until the icon appears on the Multi color display 5 Press the or Y buttons until the desired room temperature appears on the control panel display The temperature ranges from 61F 88F 16 C 31 C 6 Select the desired fan speed by pressing the FAN button NOTE During hot days the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high Reducing the length of the exhaust duct insulating the exhaust hose and window kit and keeping direct sunlight to a minimum will also i
15. r plug or extension cord 7 Do not use the unit in the immediate surroundings of a bath a shower or a swimming pool 8 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual 9 Do not let children play near this unit 10 Always inspect the cord for signs of damage before use If the power cord is damaged it must be replaced by the manufacturer or a qualified service technician 11 When cleaning the unit always turn the unit off and unplug the power cord PACKAGE CONTENTS Portable Conditioner Exhaust Hoses 2 Hose Adapters 2 Window Kit Adapter 2 Remote Control AAA Batteries 2 Window Kit 4 Sliding Panels 1 dual hose panel 1 single hose panel 2 extension panels Air Intake and Outlet Covers 2 Owner s Manual WARNING This unit has a voltage rating of 115 volts The cord has a plug as shown m A An adapter as METAL SCREW shown in C is available for connecting three blade COVER OF GROUNDED grounding type plugs to two slot receptacles The grounding lug extending from the adapter must be con nected to a permanent ground such as a properly _ grounded outlet box The adapter should not be used 1f a three slot grounded receptacle is available a GROUNDING DO NOT DEFEAT THE SAFETY PURPOSE OF THE GROUNDED PLUG SPECIFICATIONS cine MODEL ured at an ambient temperature COOLING CAPACITY of DB 86 F W
16. ting in fan mode no outdoor air exchange takes place The window kit and exhaust hose do not need to be installed when the unit 1s used as a fan NOTE The supplied window kit can be installed in sliding windows and sliding glass doors up to 8 ft long approximate length MOUNTING THE EXHAUST HOSES Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hoses approximately 6 inches Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the other end of the exhaust hose clockwise Repeat on the other exhaust hose Remove outlet covers from the back of the unit by screwing them counter clockwise then lifting up Mount the exhaust hoses onto the back of the unit by locking the hose adapters into place DUAL HOSE WINDOW KIT INSTALLATION To quickly and efficiently cool a large area Innovative products for a cleaner Installation of the Venting Kit more comfortable world FOR DUAL HOSE PORTABLE AIR CONDITIONERS The venting kit must be installed in order for the unit to work correctly in the air conditioning heating or dehumidifying mode The venting kit does not need to be used while the unit is fanning The window kit has been designed to fit into most vertical and horizontal window openings The window kit can also be used in a sliding door 1 Choose a suitable l
17. xhaust hoses and window kit to be installed to operate the unit in fan mode Heating Mode 1 Install the exhaust hoses and window kit properly see pages 6 amp 7 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel 4 Press the MODE button until icon appears on the control panel display 5 Press the Vor A buttons until the desired room temperature appears on the control panel display The temperature ranges from 61 88 F 10 esj C 6 Select the fan speed by pressing the FAN button It is recommended to set the fan speed to low NOTE When heat mode is selected the unit will shut down for 3 5 minutes then start in heating mode NOTE When the unit is running on heating mode the exhaust hoses are required and must be vented outside using the supplied window kit 10 Auto Mode 1 Install the exhaust hoses and window kit properly see pages 6 amp 7 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER button on the control panel lt 4 Press the MODE button until VW icon appears on the control panel display Select the fan speed by pressing the FAN button NOTE During AUTO mode the unit operates in Heating mode when the room temperature 1s below 68 Dehumidifier mode when room temperature 15 between 68 to 80 And Conditioner mode when the room temperature 1s above