Home
DeLonghi Fan Heater Fan User Manual
Contents
1. fast mode To change the time press pushbuttons hour for at least 5 seconds then proceed as above to modify both hours and minutes AM AUTOT 6 00 58 current time room temperature 2 MANUAL FUNCTIONING To operate the heater without timer press the ON MODE button Fig 1 By pressing the ON MODE button one or more times the appliance will select the operating heating power as follows Maximum power Medium power AM MAN oF Minimum power 6 00 58 x AM MAN oF Fan only summer ventilation 8 00 58 x Off GB 10 05 2001 9 00 Pagina 5 If Maximum power has been selected adjust the thermostat dial Fig 1 to the desired comfort temperature from 42 and 95 F 5 C to 35 C By turning the thermostat dial the display will show the selected temperature In addition the smaller characters on the righthand side of the display will indicate the actual room temperature see figure selected temperature room temperature This heater has Electronic Climate Control which automatically monitors and selects the ideal power setting to maintain your chosen temperature If the selected temperature is higher than the actual room temperature the appliance will start automatically and rapidly heat the room until it reaches the selected temperature The unit will automatically maintain the temperature at a constant level by switching between maximum medium and
2. from repairs or alterations to the appliance outside our factory or authorized service centers nor shall it apply to any appliance which has been subject to abuse misuse negligence or accidents Also consequential and incidental damages resulting from the use of this product or arising out of any breach of contract or breach of this warranty are not recoverable under this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you How Do You Get Service If repairs become necessary or spare parts are needed please write to DE LONGHI AMERICA INC Park 80 West Plaza One 4th floor Saddle Brook NJ 07663 or call Service Tel No 1 800 322 3848 or visit our internet site www delonghiusa com The above warranty is in lieu of all other express warranties and representations All implied warranties are limited to the applicable warranty period set forth above This limitation does apply if you enter into an extended warranty with De Longhi Some states do not allow limitations on how long an implied warranty lasts so the above exclusions may not apply to you De Longhi does not authorize any other person or company to assume for it any liability in connection with the sale or use of its appliance How Does State Law Apply This warranty gives you specific legal rights and you may also have other rights which vary from state to state ZOV000000000000000000
3. 000000000000000000
4. GB 19 05 2001 9 00 Pagina 1 S OWNER S INSTRUCTION MODE D EMPLOI DeLonghi INSTRUCCIONES DE USO FAN HEATER RADIATEUR SOUFFLANT TERMOVENTILADOR READ AND SAVE THESE INSTRUCTIONS LISEZ ET GARDEZ CES INSTRUCTIONS REPASE Y GUARDE ESTAS INSTRUCCIONES GB 10 05 2001 9 00 Pagina 2 f IMPORTANT SAFEGUARDS When using electrical appliances basic precautions should always be followed to reduce risk of fire electric shock and injury to persons including the following 2 Read all instructions before using the appliance This appliance is hot when in use To avoid burns do not let bare skin touch hot surfaces Use handle when moving this heater Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from the front and top of the heater and keep them away from the sides and rear Extreme caution is necessary when any appliance is used by or near children or invalids and whenever the heater is left operating and unattended Always unplug appliance when not in use Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions has been dropped or damaged in any manner Return heater to authorized service facility for examination electrical or mechanical adjustment or repair Do not use outdoors This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never locate applian
5. ce where it may fall into a bathtub or other water container Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic area and where it will not be tripped over To disconnect the appliance turn controls to off then remove plug from outlet 10 11 Connect to properly polarized outlets only Do not insert or allow foreign objects to enter any ventilation opening as this may cause an electric shock fire or damage the appliance To prevent a possible fire do not block air intakes or exhaust in any manner Do not use on soft surfaces like a bed where openings may become blocked A fan heater has hot or arcing or sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored Use this appliance only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons To prevent overload and blown fuses be sure that no other appliance is plugged into the same outlet receptacle or into another outlet receptacle wired into the same circuit It is normal for the heater s plug and cord to feel warm to the touch A plug or cord which becomes hot to the touch or becomes distorted in shape may be a result of a worn electrical outlet receptacle Worn outlets or receptacles should be replaced prior to further use of the heater Plugging hea
6. ion do not try to repair the heater yourself it may result in fire hazard or electric shock Call the nearest Service Center see attached list of Service Centers ATTENTION A safety device switches the fan heater off if it accidentally overheats An audible signal warns of any problems To reset the unit for normal operation remove the plug from the mains socket for a few minutes eliminate the cause of overheating e g air intake or outlet grilles obstructed and then plug the fan heater back in again Contact your nearest Service Center if the fan heater does not begin normal operation again e GB 10 05 2001 9 00 Pagina 8 O a VZ LIMITED WARRANTY What DoesThis Warranty Cover We warrant each appliance to be free from defects in material and workmanship Our obligation under this warranty is limited to replacement or repair free of charge at our factory or authorized service centers of any defective part or parts thereof other than parts damaged in transit which shall be returned to us transportation prepaid This warranty shall apply only if the appliance is used in accordance with the factory directions which accompany it and on an Alternating Current AC circuit How Long Does The Coverage Last This warranty runs for one year from the date of delivery and applies only to the original purchaser for use What Does This Warranty Not Cover This warranty does not cover defects or damage of the appliance which result
7. minimum power If the room temperature exceeds the selected temperature level the appliance will switch off The appliance will switch on automatically again when the room temperature falls below the selected temperature level If medium power level has been selected using the ON MODE button the appliance will modulate between medium and minimum power to maintain a selected temperature 3 ANTIFREEZE FUNCTION Press the ON MODE button to select the P max power level Set the thermostat dial to the position Fig 1 The display will show 42 F see figure When set in this way the appliance will switch on automatically only if the room temperature falls below 42 F 5 C to prevent it from freezing at minimum energy consumption The display will show LO see figure This function is not guaranteed in the event of black outs even if lasting just a few seconds GB 10 05 2001 9 00 Pagina 6 4 PROGRAMMING THE ELECTRONIC TIMER The timer allows you to set 2 programmes in a 24 hour period to programme the timer 1 Press the button AUTO fig 2 this accesses the 1st programme programme A The yellow timer ON lamp will light up is RE aat D TIMER ON O oQ TIMER ON AM_ AUTO MAN yellow lamp Ar a0 G6 oo 00 o8 auto MAX at LECTRONIC j MED ee Kems di 2 Goti a x TIMER MIN eac C SE Ls G FUNCTION FAN OFF n Ww min Fig 2 2 Set the start time fo
8. pliance is fitted with a motorized base and a rotating body To distribute the air flow over a larger area press the oversized switch Fig 3 When activated the appliance will oscillate from right to left over an angle of approximately 30 To terminate oscillating simply press the oversized switch again Fig 3 IMPORTANT You must leave the heater plugged in and switched on at the mains socket to keep the heaters memory programmed If you do not require the heater to operate in accordance with the timed programmes simply operate via the ON MODE button If the heater looses its electricity supply for more than 2 minutes e g switched off at the mains socket or in the event of a power failure the heater s programmes will be lost and the heater will not work until reset In the event of a blackout the appliance will not switch on again automatically To switch the appliance back on repeat the procedure described above MAINTENANCE AND SERVICE Always remove the plug from the power socket and allow the heater to cool After the heater has cooled clean it with a soft damp cloth do not use detergents or abrasives Periodically clean the air intake and outlet grilles during the period in which the heater is in use with a vacuum cleaner Should the heater not be in use over a certain length of time store it in a dry place This appliance has been built to provide many years of trouble free service In case of malfunct
9. r your programme by pressing the hour button to set the hour AM and PM and the min button to set the minutes 3 To select how long you require the heater to be on push button min and push repeatedly until your chosen operating timespan appears The time periods you are able to choose from are 15 30 45 1hr 2hr 4hr max AM AUTO AM AUTO am am 8 00 A 6 00 b o o starting time program A starting time program B operation time 4 To programme the a second time period programme B press the AUTO button twice and proceed as above Note The operating period must be the same as in programme A if the operating time is changed eg from 45 mins to 1hr both programmes will operate for 1 hr 5 Now set the comfort temperature as previously described by using the thermostat dial The power level will automatically be set to maximum and will reduce to the lower power levels as required The heater will switch on automatically every day at the preset time for the designated time period and will automatically maintain the selected confort temperature If you wish to cancel a programme depress the AUTO button and then the hour and min buttons until the display shows GB 10 05 2001 9 00 Pagina 7 f Time Override If you wish to operate the heater without timer press the ON MODE button The yellow timer pilot light will go off 5 MODELS WITH ROTATING BODY This ap
10. ter into a worn outlet receptacle may result in overheating of the power cord or fire Do not use an extension cord because the extension cable may overheat and cause a risk of fire However if you have to use an extension cable the cable shall be no 14 AWG minimum size and rated not less than 1875 watts and has to be used only for supplying power to this appliance Be sure that the plug is fully inserted into an appropriate receptacle Please remember that receptacles also deteriorate due to aging and continuous use check periodically if GB 10 05 2001 9 00 Pagina 3 signs overheating or deformations are evidenced by the plug Do not use the receptacle and CALL your electrician 19 Check that neither the appliance nor the power cable have been damaged in any way during transportation 20 CAUTION to prevent electric shock match wide blade of plug to wide slot fully insert 21 Do not cover the appliance while it is functioning in order to avoid overheating with the attendant risk of fire SAVE THESE INSTRUCTIONS Your product is equipped with a polarized alternating current line plug a plug having one blade wider than the other This plug will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug If the plug should still fail to fit contact your electrician to replace your obsolete outlet Do not defeat the safet
11. y purpose of the polarized plug ELECTRIC CONNECTION The fan heater must be connected to a properly polarized A C 110 120 V household outlet in perfect working condition Keep loose clothing or bedding furniture and flammable material away from the wall outlet where the heater is plugged in When you plug in the appliance the red pilot light will illuminate Fig 1 INSTALLATION The fan heater can be easily positioned on any horizontal support surface in an upright position FAN HEATER CONTROLS 7 S thermostat dial pointer TIMER ON red pilot light AM_ AUTO MAN yellow lamp Anan ELECTRONIC we uu uu OO ua 7s KE mare MED et CONTROL LO we SETTING OFF min Fig 1 GB 10 05 2001 9 00 Pagina 4 f OPERATION AND USE 1 SETTING THE CLOCK For the first time set the clock to the correct time proceeding as follows e Press the button hour until the display shows the hours for the correct time and AM or PM then release the button fig 1 e Press the button min until the display shows the minutes for the correct time then release the button fig 1 When setting the correct time the numbers will flash on the display The flashing of the numbers will continue for a few seconds after the adjustment has finished then stop on the correct time and the clock start working Keep both pushbuttons pressed for more than 3 seconds to move through the hours and minutes in
Download Pdf Manuals
Related Search
Related Contents
Samsung ND020NHXBA User Manual Nexus AXM-8200 un compact haut de gamme a zoom puissant stabilisé sur 5 axes Discovery 975 Copyright © All rights reserved.
Failed to retrieve file