Home
American Standard 4508S Indoor Furnishings User Manual
Contents
1. Cam Cap making sure the guide teeth are facing Y ERR OE SINK P outward If the Cam Cap does not snap into place then rotate L _ the Cam to make sure It is fully inserted Fig K DRAIN Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troubling Shooting Guide to complete installation Stopper will be Locked Mode in Locked mode and not be removable Unlocked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J LOOP TOWARD Re install the Cam Cap making sure the guide teeth are facing FRONT OF SINK outward If the Cam Cap does not snap into place then rotate Ce the Cam to make sure tt is fully inserted Fig K DRAIN Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Troublingshooting Guide to complete installation Stopper will be Unlocked Mode in Unlocked mode and removable INSTALL CAM CAP M968672 Rev 1 1 TIPS FOR REMOVING YOUR OLD DRAIN Most existing drains can be removed quickly and easily with o
2. ALL HANDLES Push ADAPTER 1 on VALVE STEM 2 so that the hole of the ADAPTER 1 without a spline is facing up Fig A Tighten FHREAD ON STEM SCREW 3 to secure ADAPTER 1 TO DECK ADAPTER Find correct position of LEVER HANDLE ASSEMBLY 4 by adjusting male teeth on ADAPTER 1 to female teeth in HANDLE 4 Thread LEVER HANDLE ASSEMBLY 4 onto DECK ADAPTER 5 until snug against mounting surface With HANDLES 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks Remove AERATOR 3 Operate both HANDLES 1 to flush water lines thoroughly Replace AERATOR 3 1 1 CHECK DRAIN CONNECTIONS E Operate POP UP KNOB 5 and fill Sink with water Check WASTE that DRAIN STOPPER 4 makes a good seal and retains OUTLET water in Sink If STOPPER 4 does not seal properly please refer to Troubleshooting Guide in these instructions Release POP UP KNOB 5 down and check all drain COLD connections and P trap for leaks Tighten if necessary P TRAP 1 2 CARE INSTRUCTIONS R E To change direction of handle rotation DO SIMPLY RINSE THE PRODUCT proceed as follows ei e errant EN Turn valve to OFF position Unthread HANDLE BASE 1 from DECK ADAPTER 2 CLOTH Pull HANDLE ASSEMBLY off VALVE STEM 3 1 a Remove SPRING CLIP 4 Lift STOP WASHER 5 DO NOT CLEAN THE PRODUCT turn 90 and replace Replace SPRING CLIP 4 WITH SOAPS ACID POL
3. Ambricam Standard Installation Instructions SYMPHONY 4508 Spread Lavatory Faucet with Speed Connect Drain 4508S Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Speed Connect Drain 1 3 of the parts installs in 1 3 of the time Certified to comply with ANSI A112 18 1 No tools needed M968672 Rev 1 1 Never needs adjustment Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools anes y hy Screwdriver Channel Locks Adjustable Wrench Tubing Cutter INSTALL SPOUT TUT inns before beginning Insert SPOUT 1 and CABLE CONNECTOR 12 through center hole making sure the SPOUT ESCUTCHEON 2 and SEAL WASHER 3 are properly seated m Assemble RUBBER WASHER 4 BRASS WASHER 5 and LOCKNUT 6 onto SPOUT SHANK 7 from under side of sink Make sure SPOUT 1 is centered in the mounting hole and the slot in the BRASS WASHER 5 faces toward the rear of the sink m Tighten LOCKNUT 6 firmly Fig A INSTALL VALVE BODY m Place RUBBER RING 9 into ADAPTER 10 gm Install LOCKNUT 711 onto VALVE BO
4. DY 8 From under side of mounting surface install VALVE BODY 8 through valve mounting holes Threads of VALVE BODY 8 should extent at least 5 16 of a inch above mounting surface top Fig B Thread ADAPTER 10 onto VALVE BODY 8 until snug against internal stop If necessary adjust LOCKNUT 11 Hand tighten LOCKNUT 11 to secure VALVE BODY 8 Repeat above steps for opposite VALVE BODY 8A 10 il MOUNTING SURFACE 5 16 MIN 1 ma lt F INSTALL POP UP DRAIN REAR OF Remove CLEAR PLASTIC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A Drop DRAIN BODY 4 through sink drain hole Make sure WHITE FOAM GASKET 5 is under flange of DRAIN BODY 4 Fig B Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 6 must face towards the rear of the SINK Fig B INSTALL BLACK GASKET Install BLACK CONE GASKET 1 onto DRAIN BODY 2 from below Note The flat side of the BLACK CONE GASKET 1 must face down FLAT SIDE OF GASKET MUST FACE DOWN INSTALL GRAY LOCKNUT Install GRAY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that AAT SDE OE WHITE FOAM GASKET 3 is fully compressed GRAY LOCKNUT and not visible Fig B
5. ISH Find correct position of HANDLE ASSEMBLY by adjustin 90 ABRASIVES HARSH CLEANERS male teeth on VALVE STEM 8 to female teeth in HANDLE gt OR A CLOTH WITH A COARSE Thread HANDLE ASSEMBLY onto DECK ADAPTER 2 SURFACE until snug against mounting surface UNTHREAD If spout drips operate handles several times from ACL A A OFF to ON position Do not force handles turn LL2 9A only 90 M968672 Rev 1 1 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Stopper does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the OPDAT e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connectio
6. MUST FACE UP 5 POP UP KNOB E POP UP KNOB 1 must be fully down M968672 Rev 1 1 6 ATTACH CABLE CONNECTOR m Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 0 D Fig B F CHECK OPERATION OF POP UP E Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 8 MAKE WATER SUPPLY AND WASTE CONNECTIONS NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY Thread TEE BODY 4 to SPOUT SHANK 5 Thread HOSE CONNECTOR 6 GA to VALVE CONNECTIONS 7 7A m Connect water supply to VALVE BODIES 1 1A with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 0 D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant appropriate connectors and COUPLING NUTS Connect 1 1 4 O D tailpiece on POP UP DRAIN to waste outlet 3 3 8 0 D BULL NOSE 1 2 PIPE THREAD RISERS COMPRESSION NUT FLEXIBLE SUPPLIES 3 8 COMPRESSION CONNECTION M968672 Rev 1 1 INST
7. ls Channel Locks Adjustable Wrench Phillips Screwdriver WHEN DRAIN IS REMOVED WHEN DRAIN IS REMOVED FROM ABOVE SINK FROM BELOW SINK METAL OR PLASTIC TWO PIECE METAL DRAIN BODY WITH PLASTIC DRAIN BODY DRAIN BODY PLASTIC TAILPIECE WITH PLASTIC TAILPIECE EN STOPPE STOPPE METAL STOPPER DRAIN PLASTIC UNTHREAD BODY DRAIN BODY FLANGE SINK SINK S f SINK METAL OR PLASTIC PIVOT gt PIVOT sm voUNTING L MOUNTING DRAIN BODY ROD NUT NUT and BOD NET NUT and A MOUNTING GASKET GASKET PIVOT i Ell PLASTIC PLASTIC TAILPIECE TAILPIECE P TRAP FINISHED FINISHED WALL WALL PALE M968672 Rev 1 1
8. n 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A Fig B f Fig C STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Cam Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F _ REMOVE CAM REMOVE CAM CAP M968672 Rev 1 1 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J yi Re install the
9. nly a pair of channel lock pliers or a wrench However there may be situations where it is difficult to remove your old drain or determine how the drain is disassembled Depending upon the existing Drain in your sink it is either removed from above or below the sink The illustrations below show some typical drain installations and how they are disassembled from the sink The following tips can help with some of the more common challenges in drain removal m Loosen nuts on P Trap using channel locks Suggest spraying nuts with spray lubricant to loosen any corrosion or debris that may have built up Remove P Trap half from Tailpiece Use bucket to catch any residual water in P trap E Unthread Pivot Rod Nut from Drain Body and remove Pull Stopper out from Drain Body For Drains that are removed from below Sink m Loosen Mounting Nut as far down as it will go Push Drain Body up into Sink and unthread Flange from Drain Body Remove Drain Body from below sink For Drains that are removed from above Sink m Unthread Tailpiece from Drain Body E Loosen and remove Mounting Nut and Gasket on Drain Body using channel locks Suggest Sprang nut with spray lubricant to loosen any corrosion or debris that may have built up Push Drain Body up into the Sink and remove Note If Drain body rotates while loosening Mounting Nut insert a screw driver into overflow hole to prevent Drain Body from rotating while Mounting Nut is removed Recommended too