Home
MT9083A
Contents
1. 10 Pulse width 10 ns return loss 55 dB Deviation 20 5 dB 25 C all except 850 1300 780 nm Pulse width 10 ns return loss 40 dB Deviation 0 5 dB 25 C 850 1300 780 nm 1 5 dB 11 Fresnel reflection 12 Back scattered light 0 5 dB 11 Safety measures for laser products This option complies with optical safety standards in Class 1M of IEC 60825 1 and the FDA 21CFR1040 10 USA in Class 2 the following descriptive labels are affixed to the product FDA label is only affixed to product for export to the USA THIS PRODUCT COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO 50 DATED JULY 26 2001 Light Source and Power Meter Specifications Standard on all models 12 Stabilized Light Source through OTDR port Item Specification Standard Integrated Power Meter 13 through OTDR port Item Specification Wavelength 4 Same as OTDR Maximum Input 10 dBm 5 nm 1310 nm Spectral Width 15 lt 10 nm 1490 1550 1625 nm lt 3 mn 1650 nm s1 nm 1383 nm Measurement Range 50 to 5 dBm Fiber Type Same as OTDR Fiber Type Same as OTDR Same as OTDR sd Optical Connector Same as OTDR Optical Connector Same as OTDR Output Stability 16 0 1 dB Modes of Operation 17 CW 270 Hz 1 kHz 2 kHz Laser Safety Same as OTDR Option Number MT9083A 003 Single Mode 10 125 um G 652 Fiber Type Multimode 62 5 125 um Optical Connector
2. Product Brochure MT9083A ACCESS Master 850 1300 nm OTDR for MMF 780 1310 1383 1490 1550 1625 1650 nm OTDR for SMF 000000 000000 All in One Solution for Optical Fiber Construction and Maintenance of Access FTTx LAN and Metro Networks 850 1300 nm OTDR for MMF 780 1310 1383 1490 1550 1625 1650 nm OTDR for SMF lt gt lt 5 VTA ADCESS Master MT9083A ACCESS MASTER OVERVIEW Optical fibers are a key technology in today s modern communications systems including access networks such as FTTx CATV and optical LANs Moreover optical fiber technologies are playing increasingly important roles in mobile communica tions and digital broadcasting systems Technicians maintaining these diverse systems are forced to carry a large variety of test equipment on site including OTDRs Light Sources Optical Power Meters Visible Light Sources etc as well as a notebook computer for evaluating the FTTx QoS On the other hand fiber construction requires measuring instruments with different functions and performance As an example FTTx access networks use single mode SM fiber whereas optical LANs use mul timode MM fiber In addition core and backbone networks utilize long fibers while optical access networks use short fibers both requiring different types of measuring instruments with different performance But now Anritsu s new line of MT9083A ACCESS Master OTDRs solves all these problems by providing all t
3. values over 1 minute SM fiber 2 m x17 Modulation 1 5 with 10 minute warm up 18 CW input 20 dBm At 1550 nm 23 C 2 Using Master FC connector x19 Peak power subtract 3 dB for modulated tones x20 CW model 003 At 10 dBm 1310 1550 nm At 10 dBm 850 nm 25 C model 004 005 At OdBm 1310 and 1550 nm Using Master FC connector 10 IEC Pub 60825 1Class 3R 21 CFR1040 10 Excludes deviations caused by contormance to Laser Notice N 50 issued 21 Safety measures for laser products This option complies with optical safety standards in Class 1M of IEC 60825 1 and the FDA 21CFR1040 10 USA in Class 2 the following descriptive labels are affixed to the product FDA label is only affixed to product for export to the USA THIS PRODUCT COMPLIES WITH 21 CFR 1040 10 AND 1040 11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO 50 DATED JULY 26 2001 Standard Light Source and Power Meter Built in LS MT9083A standard built in stabilized light source OPM MT9083A standard built in optical power meter Wa Ka 1650 nm SM MT9083A 055 L S mresa 086 Tato agoro nms VV Battery pack Operating temperature Discharging 20 to 60 C Storage 20 to 50 C lt 90 RH MT9083A 060 1490nm SM MT9083A 061 1625nm SM MT9083A 062 780nm SM 850 1300nm MMF MT9083A 063 1310 1550nm SM MT9083A 064 850 1300nm MMF MT9083A 065 850nm GI 780nm SM MT9083A 068 1550nm SM AC adapter Z0933A L S a
4. 28800E Class 3 Dust proof MIL T 28800E Class 2 Drip proof IP51 IEC 60529 JIS C 0920 TYPE EN61326 1997 A1 1998 A2 2001 A3 2003 Class A Annex A EN61000 3 2 2000 Class A LVD EN61010 1 2001 Pollution Degree 2 Notes 1 Typical backlight off sweeping halted at 25 C 6 hours typical continuous testing 2 Either high density value is selected depending on distance range 3 Except 780 nm 4 To be planned 5 Sampling mode normal Except models 062 068 1 second or less OTDR Specifications Model Wavelength 5 Pulsewidth 1310 30 nm 1550 30 nm 052 1650 5 nm Fiber Type 1310 1550 30 nm 1550 30 1650 5 nm 1310 1550 30 nm 1310 1490 1550 30 nm 1310 1550 1625 30 nm 058 1310 1490 1550 1625 30 nm 059 1310 1550 1625 30 nm 1383 2 nm 3 10 20 50 100 200 500 1000 2000 4000 10000 Single Mode 20000ns SMF 10 125 pm ITU T G 652 060 1490 30 nm 061 1625 30 nm 780 20 nm 780 20 1550 30 nm 063 1310 1550 30 nm 850 1300 30 nm 850 1300 30 nm 850 30 nm IEC Pub 60825 1 2001 Class1 option 051 052 060 062 1550 nm above 780 nm 5 10 ns 3 10 20 50 100 4000 ns 1000 2000 4000ns Laser 11 Safety Notes 6 25 C Pulse width 1 ps all except 850 1300 780 nm 850 1300 nm 100ns 780 nm 10ns Pulse widths 20 us Options 050 to 061 063 068 1310 1550 nm at Distance range 100 km Pulse width 4 us Options 063 064 1300 nm at Distance
5. 5 Dong San Huan Bei Road Chao Yang District Beijing 10004 P R China Phone 86 10 6590 9230 Fax 86 10 6590 9235 e Korea Anritsu Corporation Ltd 8F Hyunjuk Building 832 41 Yeoksam Dong Kangnam ku Seoul 135 080 Korea Phone 82 2 553 6603 Fax 82 2 553 6604 e Australia Anritsu Pty Ltd Unit 21 270 Ferntree Gully Road Notting Hill Victoria 3168 Australia Phone 61 3 9558 8177 Fax 61 3 9558 8255 e Taiwan Anritsu Company Inc 7F No 316 Sec 1 Neihu Rd Taipei 114 Taiwan Phone 886 2 8751 1816 Fax 886 2 8751 1817 e India Anritsu Corporation India Liaison Office Unit No S 3 Second Floor Esteem Red Cross Bhavan No 26 Race Course Road Bangalore 560 001 India Phone 91 80 32944707 Fax 91 80 22356648 060508 061121 Catalog No MT9083A E A 1 1 00 Printed in Japan 2006 12 000
6. La Ka pv en Es EN Rated AC input 100 to 240 Vac 50 60 Hz Rated DC output 12 Vdc 3 A Operating temperature Environmental conditions H R H 20 to 80 C 10 to 95 0 to 40 C 20 to 80 60 W x 34 H x 122 D mm 305 g typ R Storage temperature Ordering Information Please specify model order number name and guantity when ordering 1 Select Model Includes ACCESS Master OTDR AC charger adapter battery pack 1 line cord and user s manual Also included are choice of one OTDR connector adapter two for model 063 select these below Model Order No Wavelength Application MT9083 050 General purpose model for construction maintenance and fault location MT9083 051 General purpose model for construction maintenance and fault location MT9083 052 In service measurement integrated filter to block transmissions 1650 nm MT9083 053 General purpose model for construction maintenance and fault location MT9083 054 General purpose models for construction maintenance and fault location plus In service MT9083 055 measurement integrated filter to block transmissions 1650 nm MT9083 056 General purpose plus 1490 nm for FTTx PON applications MT9083 057 General purpose plus enhanced macrobend detection at 1625 nm MT9083 058 General purpose for any application or full spectrum characterization MT9083 059 General purpose plus supports Water Peak Testing at 1383 nm MT9083 060 FTTx PON Testing M
7. modes that automate testing and guide novice users Dedicated testing modes are available for fault location cable installation loss budget testing visual fault location and IP testing Simple Operation To simplify testing the MT9083A features dedicated meas urement modes via the top menu to automate and simplify the task at hand Top Menu 200G AUE Z 10 00 ESS 11 10h 4 Fig 3 Dedicated measurement modes simplify testing for any skill level Fault Location FAULT LOCATE mode is designed for the novice or some one who only uses an OTDR occasionally Simply connect the fiber and press START The unit will verify the fiber is connected correctly select testing parameters and provide a text response indicating fault oreak location easy to read results for any skill level General OTDR Testing For those who have more experience or would like to per form more advanced testing STANDARD OTDR mode allows the user to set all parameters and compare traces manually automatically or somewhere in between Optical Fiber Construction and Certification Planned When final cable acceptance is the task at hand CON STRUCTION mode greatly simplifies operation through its innovative wizard Select the required testing wavelengths number of fibers and file naming scheme and construction mode acts as the project manager guiding the user through the testing while ensuring consistency with testing parame ters and filenames virtually eli
8. speed gigabit serv ices The MT9083A has a built in IP Network Connection Check function that can be used for both optical fibers and optical access QoS evaluation Connection and Ping Tests The first step in testing a service is to verify continuity The built in IP Connection Test Function supports both PPPOE and DHCP services FTTx Download Speed Evaluation FTTx service performance is easily evaluated from the down load throughput Previous evaluation systems were always limited by the PC performance CPU speed memory size OS load and never provided accurate measurements Using the MT9083A Download Throughput Measurement function frees the results from the impact of PC performance and pro vides accurate results This allows the causes of drops in FTTx service speeds to be pinpointed to the network side or the user s PC side Throughput Measurement and Frame Counter The MT9083A has a two way throughput measurement func tion for efficient evaluation of guaranteed bandwidth services When an MT9083A is connected to each end of the service both the upload and download speeds can be evaluated And since the built in frame counter functions can be used to measure received frame types and to count error frames network usage efficiency can be measured easily too Gigabit Ethernet Support The MT9083A has an optional built in 1000Base T electrical interface for evaluating Gigabit Ethernet throughput up to full line rate for verif
9. 0 5 1 2 5 5 10 25 50 100 km Fault locate provides end break location end to end loss fiber length Standard OTDR user selectable automatic or manual set up Construction OTDR automated multi wavelength testing Testing Modes Light source stabilized light source CW 270 Hz 1 kHz 2 kHz output Loss test set optional power meter and light source Power Meter Visual fault locator optional visible red light for fiber identification and troubleshooting Auto or manual operation displayed in table format User defined PASS FAIL thresholds reflective and non reflective events 0 01 to 9 99 dB 0 01 dB steps Fiber Event Analysis reflectance 20 0 to 60 0 dB 0 1 dB steps fiber end break 1 to 99 dB 1 dB steps Number of detected events up to 99 Macrobend detection OTDR Trace Format Telcordia universal SOR issue 2 SR 4731 Real time sweep 0 15 second Loss modes 2 point loss dB km 2 point LSA splice loss ORL Averaging modes timed 1 3600 seconds Live Fiber detect verifies presence of communication light in optical fiber Connection check Automatic check of OTDR to FUT connection quality Trace overlay and comparison Without protector option 010 Dimensions and Mass Other Functions Operating temperature and humidity 0 to 40C lt 80 non condensing Storage temperature and humidity 20 to 60C lt 80 non condensing Environmental Conditions Vibration Conforming to MIL T
10. 000 Multilayer Testing Platform and Loss Test Sets The CMA5000 is the industry s premier test and measure or ment solution featuring Gigabit Ethernet DWDM Fast accurate and easy to use Anritsu s CMA50 line of Light SONET SDH OTDR ORL PMD and CD applications saa bs ME che Le ei oo fa Through its open architecture design the CMA5000 offers ae fs ha a a Pe ha i ss par F SRI the highest performance measurement applications in one ith up to four stable lasers in the same unit and power powerful modular platform meter calibrated to 26 different wavelengths CMA50 meets any testing requirement from FT Tx PON networks to CWDM to long haul telephony links to multimode LAN and CATV CMA 50 makes your measuring experience comprehensive yet simple and error free with tone detection auto wave length switching mode fully automatic bi directional testing option Optical Return Loss ORL option Pass Fail threshold analysis large capacity for test results storage amp RJ45 inter face Network Testing option CMA5 Optical Power Meter and CMA3000 Mobile and Fixed Access Light Source Network Tester The CMA5 Series Power Meters are ideal for attenuation and CMA 3000 is designed specifically for field technicians who power throughput measurements on point to point fiber optic install and maintain mobile access and fixed access net links The CMA5 Series Light Sources provide an economical works The CMA 3000 is a powerful tool for a wide
11. 1113 Fig 2 Spans of over 100 km are also easily tested making the MT9083A the only tool you will need for any network type Event Table with User Defined Thresholds PASS FAIL thresholds for key acceptance criteria such as splice loss connector loss and reflectance can be set in the MT9083A allowing technicians to easily assess a fiber s con dition Failing values are clearly highlighted in the event table alerting technicians of potential problems Multiple Wavelengths and Models With nine available wavelengths spanning both single mode and multimode the ACCESS Master MT9083A is sure to meet your individual needs Up to four of these wavelengths can be combined into a single optical output providing full spectrum characterization Wavelengths for Today s Networks Sometimes you just need more than the traditional 1310 and 1550 nm wavelengths to certify your next generation net works The MT9083A offers a host of specialized wave lengths including1383 nm for water peak verification of CWDM carrying fibers 1650 nm with integrated filter for live fiber troubleshooting 1490 nm for verification of voice data and IP based video services and 780 nm for in service trou bleshooting of FT Tx networks without the need for any additional filters Solutions for Various Measurement Needs Products that offer many features are often complicated to use The MT9083A however simplifies operation by offering task specific testing
12. T9083 061 Enhanced macrobend detection MT9083 062 780 nm single mode For troubleshooting live FTTx PON networks For troubleshooting live FTTx PON networks plus verification and macrobend detection MT9083 068 780 amp 1550 nm single mode on dark fibers ji 850 1300 nm multimode MIORES wee 1310 1550 nm single mode MT9083 064 850 1300 nm multimode Multimode fiber model MT9083 065 850 nm multimode Multimode fiber model 2 Select OTDR Connector Type Best unit for contractors or anyone who installs or maintains hybrid networks Optical Connector One adapter included at no charge two with models 054 055 063 must be added as a separate line item FC APC connector MAO 02 single mode only additional charge applies 111908940868 SC APC connector Wa single mode only additional charge applies PEGS EE DUN GonDEGIE MT9083A 037 MT9083A 043 HMS 10 A connector 3 Select Loss Test Set Options Optical Power Meter Must be added as separate chargeable line items MT9083A 003 SMF MMF Optical Power Meter MT9083A 004 SMF Optical Power Meter MT9083A 005 SMF High Power Optical Power Meter Visible Light Source MT9083A 002 Visible Laser Diode 12 4 Select Network Test Options Network Test Function Must be added as separate chargeable line items MT9083A 001 IP Network Connection Check Function MT9083A 011 Gigabit Ethernet Upgrade requires option MT9083A 001 4a Select Power Meter Connector Type if op
13. Universal uses MA9005A adapters Supported Wavelengths 1310 1550 1625 nm plus 1490 nm 056 058 060 1383 nm 059 1650 nm 050 051 053 054 055 057 061 Features Store reference loss table Loss Test Set Specifications Optional on all Models 3 Power meters 003 004 and 005 Optical Power Meter Option 003 004 005 2 MT9083A 004 MT9083A 005 Single Mode 10 125 um G 652 PC only for UPC connector angled Single Mode 10 125 um G 652 only for APC connector Measurement Range 9 3 to 70 dBm 23 to 50 dBm 30 to 43 dBm Wavelength Range 750 to 1700 nm 1200 to 1700 nm 850 1300 1310 1383 1490 1550 Calibrated Wavelengths 1625 1650 nm Universal uses JXXXX adapters same as OTDR 1310 1383 1490 1550 1625 1650 nm Universal uses MA9005B adapters Modulation CW 270 Hz 1 kHz 2 kHz Features Store reference loss table Visible Light Source Option 002 Central Wavelength 650 nm 15 nm at 25 C Optical Output 0 3 dBm CW Output Optical Fiber 10 125 um SMF ITU T G 652 Optical Connector 2 5 mm universal 21 Laser Safety 27 May 2001 Environmental Same as OTDR Notes 12 Some models do not support built in light source and power meter See next page 13 If option 003 004 or 005 is ordered the standard integrated power meter is not available 14 Option 059 1383 20 m x15 CW 25 C 16 CW 0 to 40 C 1 C difference between max min
14. e for higher power transmissions and loop back testing Visual Laser Source for easy fault location and fiber identification A Visible Light Source is useful for tracking down bad con nections splices and fiber management issues such as mac robends The optional Visible Light Source is factory installed in the MT9083A and features up to 5 km 3 miles of operation Optical Power Meter Options up to 30 dBm In place of the standard power meter the MT9083A offers three optional optical power meters one supports both SM and MM fibers MT9083A 003 while the others feature high er measurement range for SM only applications 004 005 When measurement of high optical powers typically more than 20 dBm like those used by CATV companies is required power meter Option 005 using an optical integra tor sphere can be used to make long term measurements with high stability at levels above 30 dBm Data Table for Saved Results Loss test set measurements for multiple wavelengths can be saved into a results table for easy comparison and archiving The table can also be saved as a text file and exported to a PC spreadsheet program for further manipulation or integra tion into a standard company template Faults that cause drops in FT Tx service speed are handled differently according to whether the cause is outside or inside the building In addition business users are starting to think about guaranteed bandwidth services and higher
15. fe plus quick recharge Numeric keypad with dedicated keys for easy operation Optical Power meter options with up to 30 dBm meas Dedicated function keys for selecting parameters urement range Rotary dial for precision cursor movement Visible laser source for easy fiber identification and bend break location Arrow keys for quick zooming and navigation through l menus Up to four wavelengths from a single port for any appli cation Dual USB ports for quick and easy data transfer 6 4 inch color TFT LCD display with simple menus IP options for verifying QoS of 10 100 1000 MB links 6006 START key for simple one button testing 00 00 Exceptional OTDR Performance from the World s First OTDR Manufacturer Evaluation of access networks ranging from a few kilometers to metro networks reaching up to 100 km in length is becoming commonplace requiring OTDRs to have the performance and functions for evaluating both short and long fibers Designed with this in mind the ACCESS Master delivers on both fronts Improved Short Fiber Analysis An event dead zone of less than 1m 80 cm typical anda sampling resolution of 5 centimeters allow the MT9083A to evaluate connections and troubleshoot central office FTTX and intra building faults with ease providing a level of detail never before seen OTDR Standard 2006 Aug 2 10 47 Fig 1 With its high resolution optics the MT9083A provides exceptional detail allow
16. he measurement functions and performance required for optical fiber construction and maintenance in a compact lightweight all in one unit that eliminates the burden of carrying many different test sets and instruments on site Whatever your work construction or maintenance long haul or intra building Anritsu has an MT9083A model for your needs Key Features e Ready to test in less than 15 seconds and all day without recharging e Specialized testing modes simplify operation e High resolution and high dynamic range ensure thorough and complete fiber evaluation Intelligent analysis software identifies problem splices connectors and even macrobends e Rugged sealed design provides years of service in the most challenging environments IP testing option verifies throughput frame loss and point to point connectivity Test up to four wavelengths with a single unit single mode multimode or both e Unique in service testing without the need for external filters Designed with the Features that Matter Most When buying products you tend to choose ones that are innovative and from established companies When you need to install and maintain optical networks this should also apply With over 50 years of combined OTDR design Anritsu which now includes NetTest delivers the features that matter Having been in the test and measurement business for a long time we understand that things like performance portability reli ability easy ope
17. ing users to quickly determine where the problem is even when events are closely spaced Active fiber check Not only can OTDR measurements be effected when the optical fiber is in service but there is a potential risk of dam age to the transmitter and OTDR receiver To prevent these problems the MT9083A verifies if light is present before starting measurement and will not transmit if it is An on screen warning and internal OTDR protection are also part of this useful feature Waveform Comparison Function Compare current and stored trace data to easily assess changes over time and to locate problems before they effect service or compare traces at different wavelengths to identify installation issues such as macrobending Integrated Macrobend Detection With many technicians making the switch from copper instal lations to optical fiber installation issues such as mac robends are bound to occur To help prevent this Anritsu has developed a macrobend detection feature for the MT9083A that will alert technicians when a possible mac robend is present This provides a higher quality of service for the customer and eliminates costly troubleshooting for you Extended Range Testing of 100 km Fibers In addition to its superb high resolution performance the MT9083A also features up to 38 5dB of dynamic range allow ing it to easily test 100 km spans making it a very useful tool for any network type OTDR Standard 2006 Aug 2
18. minating user induced errors and missing files Value Whatever your construction or maintenance needs the new ACCESS Master MT9083A is designed to reduce the time to install commission and maintain your optical networks without breaking your budget NETWORKS PC Software for Analysis and Reporting Once the data is collected NetWorks PC emulation software makes analysis and report generation a breeze Professional reports including splice loss fiber acceptance and exceptions as well as various printing options are possible with only a few mouse clicks Fig 4 Comprehensive professional reports are easily generated Fig 5 Various printing options ensure you have the results you need A True all in one Tester An OTDR Optical Power Meter Visible Light Source and IP tester are built into Anritsu s compact light weight MT9083A sup porting tasks ranging from searching for faults in optical fibers to QOS evaluation to FTTx troubleshooting with just one unit Standard Stabilized Light Source The OTDR port also functions as a stabilized light source providing continuous wave 270Hz 1kHz and 2kHz modula tions for easy fiber identification This is standard equipment on all models a chargeable option on most other OTDRs Standard Integrated Power Meter In the base unit the OTDR port also functions as an integrat ed power meter for verification of optical power levels Additional power meter options are availabl
19. range 25 km Pulse width 100 ns Options 063 065 850 nm at Distance range 25 km Pulse width 10 ns Options 062 068 780 nm at Distance range 2 5 km Averaging 180 seconds SNR 1 25 C Dynamic range one way back scattered light SNR 1 The level difference between the RMS noise level and the level where near end back scattering occurs 27 8 Level Distance Same as SMF amp 38 36 5 dB MMF 28 27 dB 200 500 1000 2000 850 nm Not Support Deadzone Backscatter lt 5 m lt 5 5 m lt 6 5 m lt 5 5 5 m lt 5 5 6 5 m Deadzone Dynamic Range Fresnel 37 5 36 33 5dB 36 34 5 34 5dB 36 34 5 31 5dB 34 32 5 32 5 29 5dB 34 32 5 29 5 33 dB 36 5 dB 83 5 dB B aB 10 ns si m 8 36 5 dB lt 5 5 5 6 m si m 80 cm typical lt 6 6 5 6 5 m lt 6 6 5 7 5 m lt 7 7 5 7 5 8 5 M lt 7 7 5 8 5 7 5 m lt 5 5 m lt 6 5 m lt 7 m 1550 nm 80 cm typical lt 7 5 5 m lt 5 5 5 m lt 4 5 m 3 4 m typical lt 1 m 80 cm typical lt 4 5 m 3 4 m typical 28 27 dB 28 dB lt 4 m 3 m typical IEC Pub 60825 1 2001 Class1 M option 050 053 055 056 057 058 059 063 064 065 21 CFR1040 10 Excludes deviations caused by contormance to Laser Notice N 50 issued 27 May 2001 9 Pulse width 3 ns Options 050 to 061 063 064 065 068 1550 nm Pulse width 5 ns Options 062 068 780 nm Return loss 40 dB 25 C Refer to the figure below
20. range of and stable laser source for use in point to point attenuation applications including fast first aid troubleshooting to com measurement They feature a rugged design built to with prehensive in depth and all layer analysis of transmission stand the difficult testing environment of fiber optic cable problems The basic CMA 3000 configuration with its two 2 installation and maintenance Mbps receivers and transmitters supports framed and unframed testing and monitoring of 2 Mbps systems 15 nritsu Specifications are subject to change without notice Anritsu Corporation 5 1 1 Onna Atsugi shi Kanagawa 243 8555 Japan Phone 81 46 223 1111 Fax 81 46 296 1264 e U S A Anritsu Company 1155 East Collins Blvd Richardson TX 75081 U S A Toll Free 1 800 267 4878 Phone 1 972 644 1777 Fax 1 972 671 1877 e Canada Anritsu Electronics Ltd 700 Silver Seven Road Suite 120 Kanata Ontario K2V 1C3 Canada Phone 1 613 591 2003 Fax 1 613 591 1006 e Brazil Anritsu Eletr nica Ltda Praca Amadeu Amaral 27 1 Andar 01327 010 Paraiso Sao Paulo Brazil Phone 55 11 3283 2511 Fax 55 11 3288 6940 e U K Anritsu EMEA Ltd 200 Capability Green Luton Bedfordshire LU1 3LU U K Phone 44 1582 433200 Fax 44 1582 731303 e France Anritsu S A 9 Avenue du Qu bec Z A de Courtaboeuf 91951 Les Ulis Cedex France Phone 33 1 60 92 15 50 Fax 33 1 64 46 10 65 eo Germany Anri
21. ration and of course price are important Quick Startup The MT9083A is ready for measurement just 15 seconds after power on so productive work can start immediately Long Battery Life Since AC power is not always available where you need it especially at fiber pedestals the MT9083A typically provides up to 8 hours of operation on a single charge This coupled with an optional car cord for cigarette lighter operation guar antees the MT9083A is ready when you are Portable With its light weight design and user friendly dimensions the MT9083A is perfect for the outside plant environment and can easily be managed with one hand The shoulder strap part of the protector option further increases portability when traveling from the truck to the testing site Rugged The MT9083A features a solid casework with no fans or vents to keep dust or moisture from entering the unit In addi tion the protector option MT9083A 010 includes rubber bumpers and a display cover for additional protection from those minor mishaps Generous Data Storage With the ability to store up to 1 000 traces in internal memory and up to 30 000 via a USB device the MT9083A offers plenty of storage for collecting and managing data No Experience Required With the MT9083A the experience is built in With specialized testing modes automatic parameter selection PASS FAIL indicators as well as features to virtually eliminate the chance to get bad
22. results the MT9083A can make anyone seems like a 20 year veteran It s not called the ACCESS Master for nothing Easy drag and drop File Transfers When the MT9083A is connected to a PC via a USB cable the internal memory of the ACCESS Master can be directly accessed Data can be selected dragged and dropped into the PC memory greatly simplifying file transfers The MT9083A also supports use of USB memory sticks Common OTDR Data Format The MT9083A supports the universal Telcordia SR 4731 issue 2 format making it compatible with not only legacy Anritsu and NetTest products but with many other vendors data Free and Simple Software Upgrades Firmware upgrades are easily performed via USB and avail able from the Anritsu website for registered users or through Anritsu customer support Compact Light Weight and All in one x With its versatile built in functions the MT9083A offers the ideal solution for efficient optical fiber construction and maintenance The MT9083A delivers full featured OTDR performance plus loss test set and quality of service measurement in a surprisingly small and lightweight package At only 28 4 cm wide x20 cm tall x7 7 cm deep and 2 2 kg 4 8 Ibs it is field portable yet rugged enough to withstand the outside plant environment When equipped with power meter visual light source and IP test options it replaces several larger pieces of test equipment Up to 8 hour battery li
23. tion 003 004 or 005 are ordered Optical Power Meter OPM Connectors One adapter included at no charge must be added as a separate line item Customer must specify adapter is desired for OPM port NOTE FC APC and SC APC are not available for OPM 5 Select Factory Installed Options Hardware Options Must be added as separate chargeable line items MT9083A 010 Protector includes rubber bumpers display cover and shoulder strap With Protector Without Protector 13 6 Select Accessories amp Replacement Items Accessories Must be added as separate chargeable line items Hard carrying case for MT9083A attach style Replacement battery pack for MT9083A External Battery Charger for MT9083A Peripherals BL 80R2 Thermal printer kit must also order BL 100W AC adapter J1314 printer cable and BL 80 30 paper rolls BL 100W AC adapter for BL 80R2 printer J1314 Printer cable for BL 80R2 printer BL 80 30 Printer paper for BL 80R2 Thermal Printer 10 rolls set Retrofit Options for existing units unit must be returned to authorized service center MT9083A 111 Gigabit Ethernet Upgrade retrofit requires option MT9083A 001 or MT9083A 101 Replacement Adapters OTDR source port Power meter MT9083A 004 J0619B MA9005A 40 MA9005B 40 Soft carrying case B0582A Hard carrying case B0583A Attache style Hard carrying case B0549 14 Related Anritsu Products CMA50 Power Meters Light Sources CMA 5
24. tsu GmbH Nemetschek Haus Konrad Zuse Platz 1 81829 Munchen Germany Phone 49 89 442308 0 Fax 49 89 442308 55 Anritsu S p A Via Elio Vittorini 129 00144 Roma Italy Phone 39 6 509 9711 Fax 39 6 502 2425 Anritsu AB Borgafjordsgatan 13 164 40 KISTA Sweden Phone 46 8 534 707 00 Fax 46 8 534 707 30 Anritsu AB Teknobulevardi 3 5 Fl 01530 VANTAA Finland Phone 358 20 741 8100 Fax 358 20 741 8111 e Denmark Anritsu A S Kirkebjerg All 90 DK 2605 Brondby Denmark Phone 45 72112200 Fax 45 72112210 Anritsu EMEA Ltd Oficina de Representacion en Espana Edificio Veganova Avda de la Vega n 1 edf 8 pl 1 of 8 28108 ALCOBENDAS Madrid Spain Phone 34 914905761 Fax 34 914905762 e United Arab Emirates Anritsu EMEA Ltd Dubai Liaison Office P O Box 500413 Dubai Internet City Al Thuraya Building Tower 1 Suit 701 7th Floor Dubai United Arab Emirates Phone 971 4 3670352 Fax 971 4 3688460 e Singapore Anritsu Pte Ltd 10 Hoe Chiang Road 07 01 02 Keppel Towers Singapore 089315 Phone 65 6282 2400 Fax 65 6282 2533 Please Contact eo P R China Hong Kong Anritsu Company Ltd Suite 923 9 F Chinachem Golden Plaza 77 Mody Road Tsimshatsui East Kowloon Hong Kong P R China Phone 852 2301 4980 Fax 852 2301 3545 e P R China Beijing Anritsu Company Ltd Beijing Representative Office Room 1515 Beijing Fortune Building No
25. ying performance on increasing common Gigabit Ethernet service Faults Identified When issues are present possible causes are displayed on screen to help isolate the source of the problem Specification MT9083A ACCESS Master Item General Specifications Size 270 W x 165 H x 61 D mm Weight 2 2 kg 4 8 lbs including battery NA SPORISC RO OPNO EN Weight 2 9 kg 6 4 lbs including battery 6 5 inch TFT LCD 640x480 with backlight transparent type Data Storage Internal memory 20 MB 1000 traces 9 External memory USB 30 000 traces with 512 MB Power Suppl 1a VDG PET 100 to 240 VAC Allowable input voltage range 90 to 264 V 50 60 Hz Type Lithium ion Battery Operating Time 8 hours Recharge Time lt 5 hours power off Power Savina Functions Backlight off disable 1 99 minutes 9 Auto shutdown disable 1 99 minutes Vertical Scale 0 05 0 125 0 25 0 5 1 25 2 5 5 6 5 dB div IOR Setting 1 000000 1 999999 0 000001steps user selectable English French German and Simplified Chinese contact Anritsu for availability of Languages others Sampling Points Normal 5001 High density 20001 or 25001 Sampling Resolution Reflectance Accuracy Single mode 2 dB multimode 4 dB Distance Accuracy 1 m 3 x measurement distance x 10 marker resolution excluding IOR uncertainty Distance Panas Single mode 0 5 1 2 5 5 10 25 50 100 200 km except 780 nm 0 5 1 2 5 km 9 Multimode
Download Pdf Manuals
Related Search
MT9083A mt9083a mt9083a2 mt9082a mt9082a1 mt9082a6 mt9082a2 mt9082a8
Related Contents
SI-8K50A - Shimano Intel DG43RK LGA-775 socket DDR3 1333/1066 MHz 8GB LED ネームプレート兼用POP① 取扱説明書 Hanns.G THG/I-INC CY199DP "取扱説明書" Fujitsu LIFEBOOK T4310 DGM4 KIT DGM4 TDG4 producer 3 manual Copyright © All rights reserved.
Failed to retrieve file