1. W Pay attention to the warning marks attached to the generator to prevent burns or serious injury Gasoline is extremely flammable and explosive under certain conditions Always refuel in a well ventilated area with the engine stopped Keep away from smoking materials sparks and other sources of combustion when refueling the generator Clean up spilled gasoline immediately Restrict operation of generator in high risk fire causing areas MMD PowerPro Inverter Generators IGR6000H 091615 Page 5 A WARNING A WARNING Page 6 Connections for standby power to a building s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections can allow electrical current from the generator to back feed into the utility lines Such back feed may electrocute utility company workers or others who contact the lines during a power outage and when utility power is restored the generator may explode burn or cause fires in the building s electrical system This generator is not designed to be connected to an automatic transfer switch Serious damage to the engine and inverter module may result Always perform a pre operation inspection before starting the engine to prevent equipment damage or accident Place the generator at least three feet one meter away from buildings or other equipment during operation
2. 3 These items should be serviced by an authorized MMD service center unless the owner has the proper tools and is mechanically proficient MMD PowerPro Inverter Generators IGR6000H 091615 Page 29 A CAUTION Make sure to turn the engine switch and the fuel cap vent lever OFF before draining oil 1 CHANGING OIL Drain the oil while the engine is still warm to assure fast and complete draining a Open left side maintenance cover b Remove the oil cap c Remove the drain bolt and drain the oil There is a rubber plug in the bottom of the generator pan that can be removed to facilitate draining the oil The generator will have to be raised off the ground and supported while the oil drains Retighten the bolt securely d Refill with the recommended oil and check the oil level e Close the left side maintenance cover Engine oil capacity Model Oil Capacity at L IGR6000H 12 14 UPPER LIMIT LOWER LIMIT OIL CAP BOLT OIL LEVEL INDICATOR Page 30 MMD PowerPro Inverter Generators IGR6000H 091615 4 NOTE BI Please dispose of used motor oil in a manner that is compliant with environment and local disposal regulations Do not throw it in the trash pour it on the ground or down the drain 2 AIR CLEANER SERVICE A dirty air cleaner will restrict air flow to the carburetor To prevent carburetor malfunction service the air cleaner regularly Service more frequently when operating the generator
3. Operate the generator on a level surface to prevent fuel spillage and or oil starvation Know how to stop the generator quickly and understand operation of all controls Never permit anyone to operate the generator without proper instructions Keep children and pets away from the generator while in operation Keep away from rotating parts while the generator is running The generator is a potential source of electrical shock when misused do not operate with wet hands Do not operate the generator in rain snow or anywhere it is exposed to moisture lI Never operate the generator with the door open or any panels removed Do not operate in any enclosure such as an RV compartment MMD PowerPro Inverter Generators IGR6000H 091615 2 Component Locations Read the labels and safety notes and precautions on the generator If a label comes off or becomes hard to read contact your sales representative for a replacement CARBON CANISTER SPARK PLUG OIL CAP Y CONTROL SERVICE PANEL DOOR AIR INTAKE AIR FILTER FUEL LEVEL INDICATOR AIR EXHAUST HIGH TEMPERATURE LABEL MMD PowerPro Inverter Generators IGR6000H 091615 Page 7 Control Panel IGR6000H OVERLOAD PROTECTOR SMART HOUR METER THROTTLE CHOKE KNOB SWITCH AC RECEPTACLES PRQTECTOR 4 OUTPUT INDICATOR 4 OVERLOAD ALARM LOW OIL ALARM FUEL VALYE CIRCUIT PROTECTOR
4. Page 12 MMD PowerPro Inverter Generators IGR6000H 091615 Check the air cleaner Check the air cleaner element to be sure it is clean and in good condition Open the left side maintenance cover Remove the air cleaner cover remove the paper components from the air cleaner cover and check air cleaner components d If the paper element is dirty or torn replace it with a new one Do not attempt to clean the element 0 oc A CAUTION Never run the engine without the air cleaner Rapid engine wear will result from contaminants such as dust and dirt being drawn through the carburetor into the engine AIR CLEANER BASE AIR CLEANER ELEMENT AIR CLEANER COVER MMD PowerPro Inverter Generators IGR6000H 091615 Page 13 4 Starting The Engine Disconnect any load from AC receptacle before starting engine A CAUTION II When starting the generator after adding fuel for the first time or after long term storage or after running out of fuel turn the fuel valve lever to the ON position then wait for 10 to 20 seconds before starting the engine 4 Starting Procedure a Turn the fuel valve lever to the ON position FUEL SWITCH b Pull the choke knob out to the CLOSED position Do not use the choke if the engine is already warm or the ambient air temperature is high Page 14 MMD PowerPro Inverter Generators IGR6000H 091615 c Insert the engine key and turn the engine switch to ON pos
5. It is very important to control the emissions of NOX and hydrocarbons as they are a major contributor to air pollution Carbon monoxide is a poisonous gas The emission of fuel vapors is a source of pollution as well The MMD PowerPro generator engine utilizes a precise air fuel ratio and emission control system to reduce the emissions of carbon monoxide NOX hydrocarbons and evaporative fuel emissions Regulation Your engine has been designed to meet current Environmental Protection Agency EPA and the California Air Resources Board CARB clean air standards if so equipped and designated The regulations dictate that the manufacturer provides operation and maintenance standards regarding the emission control system Tune up specifications are provided in the specifications section and a description of the emission control system may be found in an appendix to this manual Adherence to the following instructions will ensure your engine meets the emission control standards MMD PowerPro Inverter Generators IGR6000H 091615 Page 27 Modification Modification of the emission control system may lead to increased emissions Modification is defined as the following lI Disassemble or modify the function or parts of the intake fuel or exhaust system Modify or destroy the speed governing function of the generator Engine faults that may affect emission Any of the following faults must be repaired immediately Consult with your a
6. Keep the generator away from other electric cables or wires such as commercial power supply lines AC Power Application The generator has the capability to provide 120V and 240V AC Power It can do so simultaneously depending on the needs of the user However it is important to understand the receptacles their current limitations and how to distribute power efficiently PROTECTOR DC12V 5A AC120 2 tf e 13534 151 40V 4 0 gt OUTPUT INDICATOR 4 OVERLOAD ALARM LOW OIL 4 ALARM OVERLOAD STARTER SW RESTART FUEL VALVE AC120V AC120 240V EE VOLT SELECT 120V 20A GFCI RECEPTACLE VOLTAGE SELECTION SWITCH 120 240V 30A RECEPTACLE The GFCI ground fault circuit interrupter shuts off power to the protected receptacles if a ground fault or current imbalance between two conductors is detected If the reset button pops out the appliance connected to the receptacle may be defective If the appliance appears to be in good condition press the reset button until a click is heard This will restore power If the reset button pops out again disconnect all appliances disconnected immediately and have them inspected by a qualified electrician before attempting to use them again Page 18 MMD PowerPro Inverter Generators IGR6000H 091615 A WARNING Do not attempt to operate appliances if the ground fault circuit interrupter reset button pops out repeatedly during use
7. 6 e PUSH AC120V AC120R40V EE VOLT SELECT ENGINE FUEL SWITCH GROUND TERMINAL SWITCH OUTPUT INDICATOR LIGHT VOLTAGE OVERLOAD INDICATOR LIGHT LOW OIL ALARM INDICATOR LIGHT Page 8 MMD PowerPro Inverter Generators IGR6000H 091615 Serial Number Identification and Location The engine serial number is stamped on the engine block to the left of the oil drain plug In most cases the battery will have to be removed to view it clearly Refer to this number when ordering parts or making technical inquiries In most cases the battery will have to be removed to view it clearly ENGINE SERIAL NUMBER MODEL NUMBER SERIAL NUMBER EQUIPMENT MMD PowerPro Inverter Generators IGR6000H 091615 Page 9 3 Pre Operation Check A WARNING Besure to check the generator on a level surface with the engine stopped Under no circumstances can this generator be used in an enclosed compartment A WARNING Running the engine with insufficient oil can cause serious engine damage 1 Check the engine oil level a Open left maintenance cover and wipe the oil level indicator with a clean rag b Check the oil level by inserting the oil level indicator in the filler hole tighten and unscrew it out c Ifthe oil level is below the end of the oil level indicator refill the recommended oil up to the top of the oil filler neck ANOTE The Low Oil Alarm System will automatically stop the engine before the oil level f
8. Only the ground fault circuit interrupter receptacle provides ground fault protection Voltage Selection Switch The voltage selection switch has two positions AC120V and AC120 240V 1 When the voltage selection switch is in the 120 240V position the generator supplies both 120V and 240V AC power If you operate the generator with the switch in this position the electric current is limited to 15 amps to the 120V receptacles although it can provide 15 amps at 240V from the 120 240V receptacle 2 When the voltage selection switch in the 120V position the generator supplies 120V AC only It can supply a full 30 amps to the 30 amp receptacle or 20 amps to the GFCI receptacle Total current is limited to 45 8 amps at rated load AC operation 1 Start the engine and make sure only the output indicator light green comes on 2 Confirm that the appliance to be used is switched off and plug in the appliance The 14 30 receptacle is rated at 30 amps Should the current be exceeded the circuit protection device will activate and cut all current to the receptacle This will be indicated by the push button popping out Reduce the load to the receptacle and reset the circuit protector by pushing in the button A CAUTION Substantial overloading that continuously lights the overload indicator light red may damage the generator Marginal overloading that temporarily OFF CIRCUIT PROTECTOR A OFF lights the overlo
9. and major castings To be eligible for warranty coverage the replacement part must have been purchased in North America from an authorized MMD sales representative This warranty applies to the original retail purchaser only and is not transferable Proof of purchase is required Parts exported from North America are excluded from warranty coverage 1 Repair of replacement parts will be covered by MMD Equipment for any failure that is proven to be a failure in material or workmanship under normal use during the warranty period The warranty for replacement parts will be limited to direct replacement only with no allowance for freight and transportation charges The issuance of credit or a cash return of the purchase price will not be applicable MMD Equipment may request defective parts to be returned for examination before the issuance of credit 2 Reimbursement of labor charges to replace a defective part under its warranty period will be limited only to authorized service centers and then only if an authorized service center installed the defective part Travel time is not authorized MMD PowerPro Inverter Generators IGR6000H 091615 Page 39 13 Emission Control System Emission Control System Warranty In the United States and California new small off road engines must be designed built and equipped to meet stringent emission standards MMD Equipment must warrant the emission control system on your generator engine for the perio
10. ED BY ACCIDENT AND OR COLLISION NORMAL WEAR FUEL CONTAMINATION OR DEGRADATION USE IN AN APPLICATION FOR WHICH THE PRODUCT WAS NOT DESIGNED OR ANY OTHER MISUSE NEGLECT INCORPORATION OR USE OF UNSUITABLE ATTACHMENTS OR PARTS UNAUTHORIZED ALTERATION OR ANY CAUSES OTHER THAN DEFECTS IN MATERIAL OR WORKMANSHIP OF THE PRODUCT THIS WARRANTY DOES NOT EXTEND TO NORMAL MAINTENANCE ITEMS SUCH AS BELTS HOSES SPARK PLUGS AND FILTERS PAST THE FIRST SCHEDULED REPLACEMENT OR SERVICE INTERVAL FOR THESE ITEMS WHICHEVER COMES FIRST MMD WILL PAY FOR MINOR ADJUSTMENTS FOR A PERIOD OF NINETY DAYS FROM THE INSERVICE DATE OF THE GENERATOR MMD DENIES ANY RESPONSIBILITY FOR LOSS OF TIME OR USE OF THE PRODUCT TRANSPORTATION COMMERCIAL LOSS OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGE ANY IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THIS WRITTEN LIMITED WARRANTY The U S Environmental Protection Agency EPA require manufacturers of small off road engines to warranty their products with a two year warranty for those components that are specified as being part of the emission control system MMD Power Equipment and EPA offer the following explanation of the Emission Control Warranty In the United States and Canada new small off road engines must be designed built and equipped to meet stringent emission standards MMD must warrant the emission control system on your 2011 engine for the periods of time listed below provided there has been no ab
11. Inverter Generators IGR6000H 091615 Page 43 Notes Warranty Registration Please complete this page and FAX to 210 923 3489 Or mail a copy to MMD Equipment 602 Dunton Street San Antonio TX 78226 Attn Product Registration Retail Purchase Date Model Number Serial Number Sales Representative Sales Representative Location City State Buyer Name Address City State Zip Code E mail Notes Notes Scan for MMD technical support MMD Equipment 4175 Guardian Street Simi Valley CA 93063 602 Dunton St San Antonio TX 78226 MIMD 2075 High Hill Road Logan Township NJ 08085 EQUIPMENT www mmdequipment com S9160 Z ed 16600 L1N3lNdIno3 GW S102 LHOIHAdOO Phone 800 433 1382 Fax 800 225 5579
12. PowerPro Owners Manual IGR6000H MMD Equipment 4175 Guardian Street Simi Valley CA 93063 602 Dunton St San Antonio TX 78226 MIMD 20 5 High Hill Road Logan Township NJ 08085 Phone 800 433 1382 EQUIPMENT www mmdequipment com Fax 800 225 5579 Table of Contents 3 Ts Safety Instructions mente e dct ph eb et 5 2 KGOMMOMENE Eocalloriszae iet on teli hero pa MEM EE ER 7 3 Pre Operation 00 sss 10 A SANN HIS ENGNG ciao pet aea en EE uU Le Oe tls 14 5 GONG THOM SO usce anale edes ci tette me E 17 6 TRO ENGINE iot eise EET PEERS 26 27 8 Transporting and Storage eod tii er the ER 34 9 UNG I irai 36 107 OUDIESNOOUNO EE 37 TASS DE CIC AMONG esre E N 38 UAE EE eer er eee enone E UMP 39 13 Emission Control System e enanenensnenenensnennrnnnenrrnrnnrnrnrarirnrnnrrnnirerenene 40 Page 2 MMD PowerPro Inverter Generators IGR6000H 091615 Introduction Thank you for purchasing an MMD PowerPro Inverter Generator We are happy that you have chosen our product for all your portable energy needs This user manual covers the IGR6000H generator with EPA and California Air Resources CARB certification if do designated We strive to provide the best products and in those efforts we are constantly making improvements The information in this manual is based on the most recent information available at time of print You can always find the latest information parts and accessorie
13. ad indicator light red may shorten the service life of the generator PUSH Be sure that all appliances are in good working order before connecting them to the generator If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn off the generator engine switch immediately Disconnect the appliance and examine it for signs of malfunction MMD PowerPro Inverter Generators IGR6000H 091615 Page 19 Output and Overload Indicators The output indicator light green will remain on during normal operating conditions If the generator is overloaded or if there is a short in the connected appliance the output indicator light green will go out the overload indicator light red will illuminate and current to the connected appliance will be shut off Stop the engine if the overload indicator light red comes on and investigate the overload source Before connecting an appliance to the generator check that it is in good order and that its electrical rating does not exceed that of the generator Connect the power cord of the appliance and start the engine See page 18 for restoring electrical power ANOTE BI When an electric motor is started both the overload indicator light red and the output indicator light green may go on simultaneously This is normal if the overload indicator light red goes off after about four 4 seconds If the overload indicator light red stays on con
14. alls below the safe limit However to avoid the an unexpected shutdown it is recommended to inspect the oil level and refill regularly i n Upper limit CN AS Ad iM e REN C N a e Lower limit OIL LEVEL OIL DRAIN BOLT INDICATOR Page 10 MMD PowerPro Inverter Generators IGR6000H 091615 A WARNING Using non detergent oil or 2 cycle engine oil could shorten the engine s service life Use a high detergent premium quality 4 stroke engine oil certified to meet or exceed U S automobile manufacturer s requirements for API Service Classification SG OF Select the appropriate viscosity for the average ee temperature in your area 0 20 4 eo 0 100 Ambient Temperature SAE Viscosity Grades Single Viscosity 2 Check the fuel level a Fuel tank capacity is 5 9 gal 22L b Use automotive unleaded 87 octane gasoline only Do not use premium or high octane fuels Engine is designed to run on regular gasoline Engine damage and or poor performance may result If the fuel level is low refill to the shoulder of the fuel strainer c After refueling tighten the fuel filler cap securely d Never use an oil gasoline mixture or dirty gasoline Avoid getting dirt dust or water in the fuel tank e Afuel preservative and stabilizer should be added to any container of stored fuel LOOSEN FUEL w TIGHTEN MMD PowerPro Inverter Gener
15. asher 4 7 Wheel Clip Page 36 MMD PowerPro Inverter Generators IGR6000H 091615 10 Troubleshooting Engine will not start Fuel not reaching carburetor How to check 1 Turn off fuel valve and loosen drain screw 2 See if fuel is flowing from drain when fuel valve is turned on If the engine still does not start please take the generator to an authorized sales representative No spark from spark plug Check spark plug or replace spark plug How to check spark plug 1 Remove spark plug cap and clean any debris off sparkplug 2 Remove spark plug and install spark plug in the plug cap 3 Set the plug side electrode on the cylinder head to the ground 4 Pull the recoil starter Sparks should jump across plug gap If the engine still does not start please take the generator to an authorized sales representative Appliance does not operate Problem Corrective action Output indicator not on Check appliance equipment for defects 1 Replace appliance equipment or have repaired 2 Stop and restart engine and try again If still not operational please take the generator to an authorized sales representative Overload indicator on No power to the DC receptacle DC circuit fuse blown Replace fuse If still not operational please take the generator to an authorized sales representative A WARNING Make sure there is no spilled gasoline around spark plug Spilled fuel may ignite MMD PowerPro Inverte
16. ators IGR6000H 091615 Page 11 A WARNING WE Gasoline is extremely flammable and is explosive under certain conditions BI Refuel in a well ventilated area with the engine stopped Keep all possible ignition materials sparks and any other source of combustion away from the generator during refueling Do not overfill the fuel tank there should be no fuel above the upper limit mark After refueling make sure the tank cap is closed properly and securely Be careful not to spill fuel when refueling Make sure the area is dry before starting the engine Spilled fuel or fuel vapor may ignite Avoid repeated or prolonged contact with skin or breathing of vapor KEEP OUT OF REACH OF CHILDREN Gasoline containing alternate fuels If you decide to use a gasoline containing ethanol be sure its octane rating is no lower than the specification Do not use a blend that contains more than 10 ethanol Do not use gasoline containing methanol A WARNING Fuel system damage or engine performance problems resulting from the use of fuels that contain an improper alcohol blend are not covered under warranty Before buying fuel from an unfamiliar station determine if the fuel contains ethanol and if it does confirm the type and percentage of ethanol used Replace fuel with proper blend if you experience any undesirable operating symptoms while using a gasoline that contains ethanol or one that you think contains ethanol
17. ay be hoses belts clamps connectors and other emission related assemblies When a warrantable condition exists MMD Equipment will repair your small off road engine at no cost to you including diagnosis parts and labor Shipping of your unit to and from a warranty service center is not covered by this warranty Manufacturer s Warranty Coverage The emissions control system is warranted for two years If any emissions related part on your engine is defective the part will be repaired or replaced by MMD Equipment Owner s Warranty Responsibilities 1 As the SORE owner you are responsible for the performance of the required maintenance listing in your owner s manual MMD Equipment recommends that you retain all receipts covering maintenance on your SORE but MMD Equipment cannot deny warranty solely for the lack of receipts or for your failure to ensure the performance of all scheduled maintenance 2 As the SORE owner you should however be aware that MMD Equipment may deny your warranty coverage if your SORE or a part has failed due to abuse neglect improper maintenance or unapproved modifications 3 You are responsible for presenting your SORE to a MMD Equipment authorized service center as soon as the problem exists Warranty repairs should be completed in a reasonable amount of time not to exceed 30 days If you have any questions regarding your warranty coverage you should contact MMD Equipment Service Center at MMD Equipme
18. cations Batteries shipped with generators are warranted by the supplier Units used in rental fleets or as demonstration models will be considered commercial usage The warranty coverage is continual from the original date of purchase and does not restart upon the replacement of any part or complete unit Individual parts replaced at any point during the warranty period are only eligible for warranty coverage for the balance of the original warranty period Product Line Commercial Retail Inverter Generators To be eligible for warranty service the product must be purchased in the United States or Canada from an authorized MMD sales representative This warranty applies to the original retail purchaser only and is not transferable Proof of purchase and registration is required Parts and service labor will be covered by MMD Equipment for any failure that is proven to be a failure in material or workmanship under normal use during the applicable warranty time period This coverage is limited to parts and labor It is the responsibility of the end user to return the product to the nearest authorized repair center as directed by the warranty administration office MMD Equipment reserves the right to repair or replace any part or unit at its option MMD Equipment may request defective parts to be returned Anything replaced under warranty becomes the property of MMD Equipment THIS WARRANTY DOES NOT EXTEND TO PARTS AFFECTED OR DAMAG
19. connected simultaneously turn the Smart throttle switch to the OFF position to reduce voltage fluctuation or shutdown n DC operation turn the Smart throttle switch to the OFF position When the omart throttle is in the off position the engine runs at rated load RPM SMART THROTTLE SWITCH Page 24 MMD PowerPro Inverter Generators IGR6000H 091615 High altitude operation At high altitude the standard carburetor air fuel mixture will be excessively rich Performance will decrease and fuel consumption will increase High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor If you always operate the generator at altitudes higher than 5000 feet 1500 meters above sea level have your authorized sales representative install a high altitude main jet Even with suitable carburetor jetting engine horsepower will decrease approximately 3 5 for each 1000 feet or 305 meter increase in altitude The effect of altitude on the horsepower will be greater than this if no carburetor modification is made A CAUTION ll Operation of the generator at an altitude lower than the carburetor is jetted for may result in reduced performance overheating and serious engine damage caused by an excessively lean air fuel mixture Be sure to have any modification reversed at lower altitudes Temperature High temperature adversely affects generator operation Generator performance will decr
20. ds of time listed below provided there has been no abuse neglect improper maintenance or unauthorized application of your small off road engine If a warrantable condition is determined MMD Equipment will repair your small off road engine at no cost to you including diagnosis parts and labor Shipping of your unit to and from a warranty service center is not covered by this warranty Coverage Emissions control parts on the engine are warranted for a period of two years subject to provisions set below If any covered part on your engine is defective the part will be repaired or replaced by MMD Equipment Owner s Responsibilities You are responsible to maintain the engine as defined in your MMD Equipment Owner s Manual MMD Equipment recommends that you retain all record receipts covering maintenance on your engine but MMD Equipment cannot deny warranty claims based on a lack of receipts or for your failure to perform all scheduled maintenance You may be denied warranty coverage if a part has failed due to abuse neglect improper maintenance or unapproved applications You are required to bring your generator to an authorized MMD Equipment sales representative for repairs as soon as a problem exists For emissions warranty service contact your nearest sales representative For a listing visit www mmdequipment com warranty claims html or by calling 800 433 1382 Emission Control System Parts Coverage under this warranty extends o
21. e engine emission performance The description of durability is helpful for the user to learn the engine emission duration period and the service life of emission control system Refer to the warranty section of this owner s manual for more information Page 28 MMD PowerPro Inverter Generators IGR6000H 091615 THE AIR INDEX OF THIS ENGINE IS 3 MOST CLEAN LEAST CLEAN 2 4 6 8 10 EMISSION CONTROL INFORMATION The air quality index label is designed THIS ENGINE IS CERTIFIED TO OPERATE ON UNLEADED GASOLINE THIS ENGINE MEETS U S EPA AND CALIFORNIA EXH AND EVP EMISSION to be permanently affixed to the generator and should not be removed REGULATIONS FOR SMALL OFF ROAD ENGINES FOR 2014 MODEL YEAR ENGINE FAMILY EWKPS 3982GC EXH ECS TWC PAIR EVAP ECS CP CARB EVAP FAMILY CP3982 EPA EVAP FAMILY EWKPPNHEQ002 DISPLACEMENT 38906 EMISSIONS COMPLIANCE PERIOD 250 HOURS CHECK OWNER S MANUAL FOR FURTHER DETAILS DOM2014 J F MAMJJAS ON D Regular Service Period 1 Every 3 Every 6 ITEM Perform at every indicated month or operating hour interval whichever comes first Engine oi 56 oes LS Change o Jof 77 EL Genie 9 4 5 0 ff woene meus n9 Fuel Tank and FuelLines Lines Cheek Every 2 years Replace if necessary NOTE 1 Log hours of operation to determine proper maintenance 2 Service more frequently when used in dusty conditions
22. ease 1 for each 10 F 5 5 C increase in temperature above 85 F 29 C The normal operating range of this generator is 20 to 113 F 29 to 45 C A WARNING BI Do not operate the generator when the ambient temperature is below 20 F 29 C II Do not operate the generator when the ambient temperature exceeds 113 F 45 C MMD PowerPro Inverter Generators IGR6000H 091615 Page 25 6 Stopping The Engine To stop the engine in an emergency turn the engine switch to the OFF position IN NORMAL USE 1 Switch off the connected equipment and pull the inserted plug out PLUG FROM APPLIANCE Page 26 ENGINE SWITCH MMD PowerPro Inverter Generators IGR6000H 091615 7 Maintenance Perform maintenance and adjustment to keep the generator in the best operating condition Inspect or service as scheduled in the table below A WARNING Shut off generator before performing any maintenance If the engine must be run make sure the area is well ventilated The exhaust contains poisonous carbon monoxide gas CAUTION Use genuine parts or their equivalent The use of replacement parts that are not of equivalent quality may damage the generator BI When repairing or replacing the accessories of emission control system make sure to use the EPA standard accessories Emission control system Emission source Exhaust gas contains carbon monoxide nitrous oxide NOx and hydrocarbons
23. ect as necessary by carefully bending the side electrode g Install the spark plug carefully by hand to avoid cross threading h After a new spark plug has been seated by hand it should be tightened 1 2 turn with a wrench to compress the sealing washer If a used plug is being reinstalled it should only require 1 8 to 1 4 turn after being seated i Reinstall the spark plug cap j Close and latch the service door Page 32 MMD PowerPro Inverter Generators IGR6000H 091615 A CAUTION he spark plug must be securely tightened An improperly tightened plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range Spark arrester maintenance 4 SECONDARY GULP VALVE SPARK ARRESTER REAR COVER Remove the generator rear cover to access the spark arrestor Remove the spark arrestor from the muffler by unscrewing the clamp Clean the spark arrestor with a stiff wire brush Replace if the wire mesh is perforated or torn Reinstall the spark arrester Reinstall rear cover A WARNING Bi ifthe generator has been running the muffler will be very hot Allow it to cool before proceeding CAUTION Bi he spark arrester must be serviced every 100 hours to maintain its efficiency ANOTE W inspect the spark arrester screen for holes or tears Replace as necessary rp dox we p MMD PowerPro Inverter Generators IGR6000H 091615 Page 33 8 Transp
24. er ANOTE The DC receptacle may be used while the AC power is in use The DC receptacle is protected from an overload with a fuse If the DC circuit is overloaded the 5 amp fuse will blow and power to the DC receptacle will cease The red light on the DC panel will illuminate The fuse is located to the left of the receptacle and is accessed by snapping open the access door Replace the fuse with one of the same capacity Using a higher rated fuse may cause damage to the generator alternator 5 AMP FUSE ACCESS DOOR Page 22 MMD PowerPro Inverter Generators IGR6000H 091615 Low oil alarm system The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase falls below a safe limit the low oil alarm system will automatically shut down the engine the engine switch will remain in the ON position If the low oil alarm system shuts down the engine the red low oil alarm indictor light will come on when you operate the starter and the engine will not run If this occurs search for any oil leaks Add engine oil to resume normal operation Air Conditioning Operation For best results the SMART throttle switche should be in the off position Bring the generator to normal operating temperature before applying the air conditioning load Always allow a 2 minute wait period when manually cycling an air conditioner o
25. explosive under certain conditions lI Do not smoke or allow flames or sparks in the area 3 Change the engine oil see page 30 Page 34 MMD PowerPro Inverter Generators IGR6000H 091615 4 Spark plug and engine a Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder b Crank the engine several revolutions to distribute the oil and then reinstall the spark plug b Slowly pull the starter grip until resistance is felt At this point the piston is coming up on its compression stroke and both the intake and exhaust valves are closed Storing the engine in this position will help to protect it from internal corrosion ANOTE lI Recharge the battery once a month while storing Fuel Treatment and Exercising the Generator Any small engine is very susceptible to fuel varnishing Fuel systems have very small orifices and passageways which can easily become clogged by fuel residue that takes the form of gum and varnish This can lead to hard starting and rough running and possibly cause the engine not to start at all As EPA regulations dictate no kits available to renew a carburetor carburetor replacement will be necessary Fuel preservatives are readily available at leading RV and marine retailers Regularly add a fuel preservative to the generator fuel tank or fuel supply Drain the carburetor bowl prior to any storage period longer than 30 days It is essential that the generator be exercised on a reg
26. ff and on Alonger wait period may be required under unusually hot weather conditions BI Additionally all other loads should be turned off until the air conditioner has started and is performing normally It is also important to follow the air conditioner manufacturer s instructions for starting and restarting for proper operation Some air conditioner manufacturers offer a start capacitor or rapid start kit The lack of a start capacitor can cause the air conditioner to draw too high a starting current and overload the generators Contact your air conditioner manufacturer if you consistently have problems starting your air conditioner This generator is not generally recommended for air conditioners exceeding 13 500 BTUs MMD PowerPro Inverter Generators IGR6000H 091615 Page 23 SMART Throttle When the SMART throttle is placed in the on position engine speed is kept at idle automatically when the electrical load is disconnected and returns to the proper speed required by the electrical load when the load is reconnected The engine speed varies according to the amount of load applied to the generator Placing the smart throttle in the on position is recommended to minimize fuel consumption and engine noise while in operation A WARNING The Smart throttle system does not operate efficiently if the electrical appliance will be used in a rapid on off or low to high rpm mode lI When high electrical loads are
27. in extremely dirty areas A WARNING Do not use gasoline or low flash point solvents for cleaning They are flammable and explosive under certain conditions CAUTION BI Never run the generator without the air cleaner otherwise rapid engine wear may result a Open service door b Unsnap the clips and remove the air cleaner cover c If the paper element is dirty torn or replacement is called for based on hours of operation replace it with a new one Do not attempt to clean the element d Reinstall the air cleaner cover e Close and latch the service door AIR CLEANER BASE AIR CLEANER ELEMENT AIR CLEANER COVER MMD PowerPro Inverter Generators IGR6000H 091615 Page 31 3 SPARK PLUG MAINTENANCE To ensure proper engine operation the spark plug must be properly gapped and free of deposits Recommended spark plug WR7DC To ensure proper engine operation the spark plug must be properly gapped and free of deposits a Open the service door b Remove the spark plug cap c Use the wrench provided to remove the spark plug d Clean any dirt from around the spark plug base SPARK PLUG WRENCH 5 PLUG GAP 0 028 0 031in 0 7 0 8mm SPARK PLUG e Visually inspect the spark plug Discard if the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused f Measure the plug gap with a feeler gauge The gap should be 0 028 0 031in 0 7 0 8mm Corr
28. indows and protected from rain and snow Check for spilled fuel or leaks Clean and or repair before use Always stop engine before refueling Wait 5 minutes before restarting Keep any source of ignition away from fuel tank at all times The portable generator is not meant to be used as a permanent back up power system for the home Indicates a strong possibility of severe personal injury or death if instructions are not followed Indicates a possibility of personal injury or equipment damage if instructions are not followed Provides helpful information MMD PowerPro Inverter Generators IGR6000H 091615 1 Safety Instructions A WARNING SE A WARNING 3 AS A WARNING A WARNING This generator is designed to provide safe and dependable service if operated according to instructions BI Read and understand the Owner s Manual before operating the generator Failure to do so could result in personal injury or equipment damage Exhaust gas contains poisonous carbon monoxide Never run the generator in an enclosed area Be sure to provide adequate ventilation Do not touch muffler while it is hot The muffler becomes very hot during operation and remains hot for several minutes after stopping the engine Let the engine cool before storing the generator indoors The engine exhaust system will be heated during operation and remain hot immediately after stopping the engine
29. ition ENGINE SWITCH d Turn the engine switch to the START until the engine has started Do not operate the starter for more than 10 seconds ENGINE SWITCH MMD PowerPro Inverter Generators IGR6000H 091615 Page 15 e Push the choke knob in to the OPEN position as the engine warms up A CAUTION CHOKE KNOB lI Do not operate the generator when the ambient temperature is below 20 F 29 II Do not operate the generator when the ambient temperature is above 113 F 45 C MMD PowerPro Inverter Generators IGR6000H 091615 Page 16 5 Generator Use Warnings and cautions A WARNING Bil Jo prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy cable between the generator s ground terminal and an external ground source Connections for standby power to a building s electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes Improper connections can allow electrical current from the generator to back feed into the utility lines Such back feed may electrocute utility company workers or others who contact the lines during a power outage When utility power is restored the generator may explode burn or cause fires in the building s electrical system Do not connect the generator to an automatic transfer device Severe damage to the inverter module may
30. nly to the emissions control parts listed below 1 Fuel System 5 Crankcase Breather System A Carburetor gaskets A Breather assembly B Fuel lines fittings and clamps B Breather tube C Fuel filter if equipped 6 Air Injection System D Fuel pump if equipped A Secondary air injection valve E Carburetor T Fuel Tank Evaporative Emissions Control System 2 Intake System A Fuel tank A Air cleaner assembly B Fuel cap B Intake manifold C Carbon canister and brackets 3 Ignition System 8 Miscellaneous Items used in above A Ignition coil A Hoses connectors and fittings B Spark plug B Electrical switches 4 Exhaust System A Catalytic converter if equipped B Exhaust manifold C Gaskets Page 40 MMD PowerPro Inverter Generators IGR6000H 091615 CALIFORNIA EMISSIONS CONTROL WARRANTY STATEMENT The California Air Resources Board CARB and MMD Equipment are pleased to explain the emissions control system warranty on your 2011 and later small off road engine SORE In California new SOREs must be designed built and equipped to meet the State s stringent anti smog standards MMD Equipment must warrant the emissions control system on your SORE for the period of time listed below provided there has been no abuse neglect or improper maintenance of your SORE Your emission control system may include parts such as the carburetor fuel tank fuel cap fuel lines the ignition system and catalyst muffler Also included m
31. nt Phone 800 433 1382 E mail warranty 9 mmdequipment com If so designated your generator has an engine that has been approved by the California Air Resources Board Other than the tune up procedures specified in the maintenance section no additional maintenance is required The emission control system has the following components 1 Fuel System The fuel tank cap indicator and hoses are specially designed and constructed to not allow fuel vapors to permeate and be released to the atmosphere 2 A carbon activated canister collects gasoline vapors from the fuel tank and returns them to the combustion chamber for burning 3 A catalyst is built into the muffler to further treat the engine exhaust 4 A secondary air injection valve adds combustion air to ignite unburned fuel in the exhaust Contact your authorized MMD Equipment service center to obtain the correct replacement parts and service on this system MMD PowerPro Inverter Generators IGR6000H 091615 Page 41 Inlet system _ AIR FILTER SHELL SEAL GASKET s FILTER ELEMENT AIR FILTER COVER Certificate No X680BM Q 08 006 Certificate No 4 6 Carbon canister 650cc Curved hose Fixed frame Bolt Connected to air filter Page 42 MMD PowerPro Inverter Generators IGR6000H 091615 Carbon canister location Bracket Exhaust system SECONDARY AIR INJECTION VALVE BOLT EXHAUST PIPE MMD PowerPro
32. orting and Storage To prevent fuel spillage when transporting or during temporary storage the generator should be secured in its normal upright operating position with the engine switched OFF Fuel vapors or spilled fuel may ignite Transporting the generator with gasoline in the fuel tank is prohibited Transporting A WARNING When transporting the generator in a vehicle drain all fuel from the generator og Do not operate the generator while it is on or in a 4 vehicle Take the generator out of the vehicle and 2 use it in a well ventilated area DRAIN _ gt ma PLUG KAS Avoid a storage area exposed to direct sunlight when putting the generator in a vehicle If the generator is left in an enclosed vehicle for many hours high temperature inside the vehicle could cause residual fuel to vaporize resulting in a possible explosion Do not drive on a rough road for an extended period with the generator on board Storage Before storing the unit for an extended period 1 Clear storage area of excessive humidity and dust 2 Drain all gasoline from the fuel tank into an approved gasoline container a Turn the engine switch ON and loosen the carburetor drain screw and drain the gasoline from the carburetor into a suitable container b Tighten the carburetor screw close the fuel valve lever and left side maintenance cover A WARNING WE Gasoline is extremely flammable and
33. r Generators IGR6000H 091615 Page 37 11 Specifications Mee IGR6000H Rated Output watts 5500 Rated Current amp 45 8 22 9 Maximum Output watts 6000 Single O Parallel operation allowed Maximum Current amp 50 25 AC Voltage 120 240 Frequency Hz DC Output Air cooled single cylinder 4 stroke OHV with electronic ignition 60 Displacement cc iscosity chart 14 61 Engine Type Compression Ratio Ignition System Regular unblended automotive gasoline 87 octane Lube Oil SAE 10W30 see viscosity chart Oil Capacity qt L 1 2 qt 11 6L Noise Level no 7 dn load dB 23 63 70 Rated load continuous run time hrs E Fuel tank capacity gal 5 9 32 25 x 19 5 x 23 5 23 Spark Plug WR7DC Dimensions LxWxH in Dry Weight Ib Receptacles 2 125V GFCI 20A L14 30 125V 240V T Lock 30A Tune Up Specifications Spark Plug Gap 0 024 0 028 in 0 6 0 7 mm Valve Clearance Intake 0 0039 0 0008 in 0 10 0 02 mm Valve Clearance Exhaust 0 0059 0 0008 in 0 15 0 02 mm Page 38 MMD PowerPro Inverter Generators IGR6000H 091615 12 Warranty For all MMD Equipment PowerPro Inverter Generators Buyer Information Generators that are supplied with applicable products as standard original equipment are covered by this warranty from the date of original retail purchase for a period of three years for residential use and one year for commercial appli
34. r can be damaged lI Connect the positive battery terminal to the positive charging cord Do not reverse the charging cables or serious damage to the generator and or battery may occur A WARNING Batteries give off explosive gases keep spark flames cigarettes and other sources of ignition away Provide adequate ventilation when charging W Batteries contains sulfuric acid electrolyte Contact with skin or eyes may cause severe burns Wear protective clothing and a face shield f contact is made with skin flush with water immediately f contact is made in eyes flush with water immediately for at least 15 minutes and contact a physician Battery contents are poisonous If swallowed drink large quantities of water or milk and follow with milk of magnesia or vegetable oil and call a physician KEEP OUT OF REACH OF CHILDREN MMD PowerPro Inverter Generators IGR6000H 091615 Page 21 2 Start the engine ANOTE The DC receptacle may be used while the AC power is in use An overloaded DC circuit will trip the DC circuit fuse The fuse must be replaced before the DC receptacle is operative A CAUTION Replace the fuse with one of the same size and rating 5A Exceeding the current rating may lead to alternator damage A CAUTION The DC output is to be used to charge batteries only Serious damage to the stator windings can occur if connected to a DC motor or transform
35. result CAUTION he total wattage of all appliances connected must be considered Limit operation requiring maximum power to 30 minutes For continuous operation do not exceed the rated power of 2800 watts or 23 3 amps Do not exceed the current limit specified for any one receptacle lI Do not connect the generator to a household circuit This could cause the damage to the generator or to electrical appliances in the house Do not modify or use the generator for other purpose than it is intended for lI Do not attempt to connect generators in parallel lI Do not connect an extension to exhaust pipe BI When an extension cable is required make sure you use the proper size and length 16 Gauge Cords Any 16 gauge cord between 0 100 feet 0 30 5 meters long will adequately handle tool and appliance loads up to 10 amps MMD PowerPro Inverter Generators IGR6000H 091615 Page 17 14 Gauge Cords a 14 gauge cord between 0 50 feet 0 15 2 meters long will adequately handle loads between 10 and 15 amps 12 Gauge Cords If your load is between 10 and 15 amps and the length of the cord is 50 100 feet 15 2 30 5 meters you need a 12 gauge cord to safely power any tool The DC receptacle can be used while the AC power is in use If both are being used at the same time be sure not to exceed the total power for AC and DC Most appliance motors require more than their rated wattage for start up
36. s on our website We recommend reading this manual thoroughly before use to prevent any damage to the product or personal injury This manual should always be kept with the generator and should remain with generator if resold Reference For your reference please record the model serial number see page 9 sales representative and date of purchase Model Serial Sales Representative and date of purchase Our generators are designed to provide safe and dependable service if operated according to instructions Read and understand the Owner s Manual before operating the generator Failure to do so could result in personal injury or equipment damage If a problem should arise or if you have any questions about the generator consult an authorized sales Scan for MMD representative or MMD Equipment at technical support mmdequipment com tech support html MMD PowerPro Inverter Generators IGR6000H 091615 Page 3 A WARNING A WARNING A CAUTION ANOTE Page 4 Failure to properly follow these precautions can result in property damage serious injury or DEATH Read all labels and the owner s manual before operating this generator Generators produce carbon monoxide a poisonous colorless odorless gas that can cause death or serious injury Indoor use of a generator CAN KILL QUICKLY Generators should be used outdoors only Generators should be used outdoors only and away from garages and open w
37. sult your generator sales representative Overload Reset Switch Should the generator overload AC power will be cut off CIRCUIT PROTECTOR but the engine will stay running Correct the overload O O condition and then press the overload reset switch on OFF the front panel AC power will be restored immediately OFF PUSH Page 20 MMD PowerPro Inverter Generators IGR6000H 091615 DC Operation The DC receptacle may be used for charging 12 volt automotive type batteries only It is not designed to operate DC motors or transformers Output voltage is 15 30V DC output will vary according to the position of the Smart throttle switch 1 Connect the charging cable to the DC receptacle of the generator and then to the battery terminals A WARNING Bl Jo prevent the possibility of creating a spark near the battery connect the charging cable first to the generator then to the battery After charging disconnect the cable first at the battery Before connecting charging cables to a battery that is installed in a vehicle disconnect the vehicle s ground battery cable Reconnect the vehicle s ground battery cable after the charging cables are removed This procedure will prevent the possibility of a short circuit and sparks if accidental contact is made between a battery terminal and the vehicle s frame or body CAUTION lI Do not start an automobile engine with the generator still connected to the battery The generato
38. ular basis This will prevent the accumulation of varnish or sludge in the fuel system and also remove moisture from the generator windings Additionally it will lubricate the engine seals other moving components and keep the battery charged Exercise the generator by running it with at least 50 load for one hour every month MMD PowerPro Inverter Generators IGR6000H 091615 Page 35 9 Wheel Kit To install the front wheels install a washer on the axle then the wheel another washer and secure with a wheel clip To install the locking swivel wheels line up the bolt holes in the chassis with the holes in the wheel attaching plate secure with the 4 bolts 1 Washer 4 Wheel 3 Lock pin 4 Locking swivel wheel 5 Bolt M6X16 Assembly 1 Install the four support brackets and secure with bolts 2 Attach the front stabilizers to the chassis below the handles 3 Attach the axle assembly 4 Install one washer on the axle against each welded stop 5 nstall the two wheels 6 Install the two remaining washers and secure with the wheel clips The handles are preassembled before packaging To raise the handles 1 IG6000H Chassis installed simply raise the handle assembly to 2 Support Bracket 4 a horizontal position To retract the 3 Front Stabilizer 2 handles slide the chrome collars toward you to clear the sleeve and lower them 5 seen to the starting position 5 10 Wheel 6 Wheel W
39. use neglect improper maintenance or unauthorized application of your small off road engine If a warrantable condition is determined MMD Equipment will repair your small off road engine at no cost to you including diagnosis parts and labor Emissions control parts on the engine are warranted for a period of two years subject to provisions set below If any covered part on your engine is defective the part will be repaired or replaced by MMD Power Equipment You are responsible to maintain the engine as defined in your MMD Generator Owner s Manual MMD recommends that you retain all record receipts covering maintenance on your engine but MMD Equipment cannot deny warranty claims based on the lack of receipts or for your failure to perform all scheduled maintenance You may be denied warranty coverage if a part has failed due to abuse neglect improper maintenance or unapproved applications Repair or replacement parts are warranted for ninety 90 days from the date of purchase Any part replaced during the base warranty period assumes the remainder of that warranty period or ninety 90 days whichever is greater An exception is made for the following parts which will be warranted for six months 180 days from date of purchase Selected generator parts alternator assembly stator rotor inverter module Selected power train parts replacement long block cylinder block cylinder head crankshaft camshaft balance shaft manifolds
40. uthorized MMD Equipment service center for diagnosis and repair Hard starting or shut down after starting Unstable idle speed Shut down or backfire after applying an electrical load Backfire or after fire Black smoke and or excessive fuel consumption Replacement parts and accessories The parts making up the emission control system applied to the engines have been specifically approved and certified by the regulatory agencies You can trust the replacement parts supplied by MMD Equipment have been manufactured to the same production standard as the original parts The use of replacement parts or accessories which are not designed by MMD Equipment may affect the engine emission performance The manufacturers of replacement parts and accessories have the responsibility to guarantee that their replacement products will not adversely affect emission performance Maintenance Maintain the generator according to the maintenance schedule in this section More frequent maintenance should be performed when used in dusty areas under conditions of high load temperature and humidity Air Quality Index only for California certified models CARB requires that an air quality index label be attached to every certified engine showing the engine emission information for the emission duration period The label is provided for the user to compare the emission performance of different engines The lower the air index the better th
Download Pdf Manuals
Related Search
Related Contents
Kodak C623, C623 Digital Camera User Manual 取扱説明書を必ずご参照下さい Philips 24PFL4208K/12 24" HD-ready Smart TV Wi-Fi Black LED TV JVC LPT0666-001A User's Manual 制御用アプリケーション取扱説明書 LBH-1790 PRECAUCIONES DE SEGURIDAD (ESPAÑOL) 技術的審査依頼に必要な図書(PDF) インストール全体像 - ソフトマティック Cisco Small Business SF110D-05 Copyright © All rights reserved.