USER MANUAL MODEL 506 & 507 Surge Protected DB
Contents
1. modular cable into the jack on the Model 506 or 507 If you have a Model 506 the cable must be terminated with an RJ 11 plug If you have a Model 507 the cable must be terminated with an RJ 45 plug 4 To provide an alternate ground connection use the short strap supplied with the unit Connect one loop to the device chassis or other chassis ground and the other loop to the Model 506 or 507 as shown below Connect to D Sub Screw a RR 4 Connect to a Chassis Ground am Figure 1 How to Connect the Patton Model DB 25 to Your PC Modem or Printer APPENDIX A MODEL 506 amp 507 SPECIFICATIONS Peak Power Dissipation Response Time Breakdown Voltages Capacitance Cable Length Burden 1500W 10 x 1000uSec in Compliance with IEC 801 5 Level 3 2kV Models 506F 25 506M 25 507F 25 507M 25 507X RS 232 Clamped to 27V after 0 5usec RS 422 Clamped to 6 8V after 0 5usec 27V for RS 232 6 8V for RS 422 less than 500pF less than 9 1 2 8m Copyright 1997 Patton Electronics Company All Rights Reserved 5 Dear Valued Customer Thank you for purchasing Patton Electronics products We do appreciate your business I trust that you find this user manual helpful We manufacture one of the widest selections of data communications products in the world including CSU
2. with the manufacturer s instructions may cause interference to radio and television reception They have been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If these products do cause interference to radio or television reception which can be determined by turning off the unit the user is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 1 2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive LVD of the Union European EU A Certificate of Compliance is available by contacting Technical Support 1 3 SERVICE All warranty and nonwarranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from P
3. DSU s network termination units powered and self powered short range modems fiber optic modems interface converters baluns electronic data switches data line surge protectors multiplexers transceivers hubs print servers and much more We produce these products at our Gaithersburg MD USA facility and can custom manufacture products for your unique needs We would like to hear from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales patton com Support E mail support patton com Phone Sales 301 975 1000 Phone Support 301 975 1007 Fax 301 869 9293 Mail Patton Electronics Company 7622 Rickenbacker Drive Gaithersburg MD 20879 USA We are committed to a quality product at a quality price Patton Electronics is ISO 9001 certified We meet and exceed the highest standards in the industry CE UL etc It is our business to serve you If you are not satisfied with any aspect of this product or the service provided from Patton Electronics or its distributors please let us know Thank you Burton A Patton Vice President P S Please tell us where you purchased this product
4. USER MANUAL MODEL 506 amp 507 Surge Protected DB 9 to Modular Adapters PE PATTON M ElectronicsTo ISO Part 07M506 50 B SALES OFFICE a 9061U 301 975 1000 ev In Es asatie TECHNICAL SUPPORT 301 975 1007 An 150 9001 http www patton com Certified Company 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 506 amp 507 components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 506 amp 507 Series units generate and use radio frequency energy and if not installed and used properly that is in strict accordance
5. atton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your Patton Model 506 amp 507 Technical Service hours 8AM to 5PM EST Monday through Friday 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for One Year parts and labor If any questions arise during installation or use of the unit contact Patton Electronics Technical Support at 301 975 1000 2 1 PRODUCT DESCRIPTION The Patton Model 506 amp 507 Surge Protected DB 9 to Modular Adapters allow you to simplify cabling connections and protect your RS 232 or RS 422 DB 9 equipment at the same time Each adapter is custom wired according to your pin out diagram no standard wiring Up to 1500 Watts of surge protections per modular pin is provided On the Models 506 an RJ 11 jack is used and up to 6 pins may be protected On the Model 507 an RJ 45 jack is used and up to 8 pins may be protected Both the Model 506 and 507 employ Silicon Avalanche Diodes for superior transient protection You may specify a clamping voltage of 27V for RS 232 applications or 6 8V for RS 422 applications Surges are shunted safely to chassis gro
6. und through the D shell connector Male or female DB 9 connectors are available Warning These products will not provide complete protection should your equipment be subject to a direct lightning hit 2 2 SURGE PROTECTION BENEFITS The method of surge protection used in the Models 506 amp 507 adds four benefits to your system 1 High Surge Capacity The Models 506 amp 507 dissipate up to 1500 Watts per wire in 1 0 millisecond 2 Quick Response The Models 506 amp 507 have a fast response time of 1 picosecond 0 5 microsecond installed 3 Low Impedance The Models 506 amp 507 add minimal load to your system about the same as a gender changer 4 Open Failure The Models 506 amp 507 fail open if your system experiences a severe transient or power fault above the rated voltage of the protector This means that data and surge energy is shunted directly to chassis ground rather that being allowed to flow throughout the system 3 0 INSTALLATION The Patton Models 506 amp 507 are simple to install and require no user configuration Follow these installation steps 1 Be sure the metal D sub connector on the device you are protecting is connected to frame ground If not see step 4 below 2 Plug the DB 9 connector of the Model 506 or 507 directly into the DB 9 Serial port ofthe device you are protecting Use ofa serial cable reduces the effectiveness of the protection you would otherwise receive 3 Plug your