1. seconds to indicate unit is armed Classic s Anatomy 1 Lamp cover 2 UV lamp 3 Water sensor pins 4 Activation button 5 Indicator LED 6 Battery cap Specifications Treatment size 0 5 or 1 liter Treatment time 48 or 90 seconds Lamp life 8 000 activations Treatments per set of batteries up to 100 80 with rechargeable Minimum bottle opening 20mm Weight with disposable lithium 4 batteries 156g Weight with rechargeable NiMH batteries Energizer 208 5g 193 x 38 x 38mm Battery Guide Remove battery cap by rotating counterclockwise so that cap arrow points to open lock icon Install AA batteries with polarities as shown in battery compartment Replace battery cap by aligning cap with open lock icon Then rotate cap clockwise until arrow points to closed lock icon Classic runs on disposable lithium batteries or rechargeable nickel metal hydride NIMH AA batteries with a 2300mAh capacity DO NOT USE ALKALINE BATTERIES For best results always use quality name brand batteries like Energizer or Sanyo Eneloop Pre Filter s Anatomy 1 Air vent not for drinking 2 Filter cartridge 1 3 Pre Filter base 4 Bottle gasket 2 Specifications Nominal filter size 40 microns Weight 45g 47 5 x 67 9mm diameter Pre Filter removes large particles such as leaves twigs sand and other debris for improved effectiveness of UV purification It is not intended as
2. is this normal What you are seeing is a small bead of silicone used as a Shock absorber to protect the lamp What happens when I ve used Classic 8 000 times Classic s LED indicator will flash red three times then green once to indicate that its bulb is exhausted Contact us to have it replaced Classic s bulb is shining a purple rather than blue light is it still working Yes The visible light indicates that the bulb is working regardless of its color Can take Classic on a plane Yes Classic and all SteriPEN products are allowed in carry on bags as well as checked luggage Classic will work in any country to destroy bacteria viruses and protozoa Does altitude affect Classic s ability to purify water No SteriPEN technology and product design have been tested and used on Mount Everest for years Can use Classic to treat more than 1 liter ata time No we do not recommend it Classic s effectiveness is ONLY tested and certified for volumes up to 7 liter You can however treat and combine multiple 1 liter volumes of water What about parasites like worms and their eggs Does Classic treat for them Due to animal testing restrictions Classic s effectiveness against such parasites has not been certified Can Classic treat soda Iced tea Juice No UV light may not effectively destroy microbes in beverages other than water Patented amp Certified SteriPEN technology is patent
3. rique de la classe B est conforme a la norme NMB 003 du Canada NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment under FCC rules ce X fe Intertek
4. DEG i i Stari FE nN gasse IDUIBMO IY Safe drinking water Anywhere Anytime PAG Hydro Photon Inc PO Box 675 262 Ellsworth Road Blue Hill ME 04614 USA Toll Free USA 1 888 SteriPEN 1 207 374 5800 info steripen com www steripen com SPPF UG 1210 2013 Hydro Photon Inc The best selling portable UV purifier Thanks for choosing the SteriPEN Classic and congratulations on your purchase Classic is built to be safe simple and straightforward lf after reading this guide you have any questions please don t hesitate to call us at 1 888 826 6234 We love hearing from you Also be sure to visit us online and register your Classic for all the latest news and special deals Thanks again and happy travels from your friends at SteriPEN PS Don t forget to recycle the packaging www steripen com facebook com steripen steripen Easy to Use Step 1 Remove lamp cover Pull away from the lamp Take care not to wet Classic s water sensor pins before activating Step 2 Press activation button 1x for 1 liter treatment 2x for 0 5 liter treatment LED will flash green for 15 Step 3 Submerge and stir When water sensor pins detect water lamp will illuminate until treatment is complete When lamp turns off LED indicator will display treatment success or failure see Classic LED Indicator Guide section Be sure to wipe bottle threads dry before drinking
5. a purificaiton method To store Pre Filter insert filter cartridge with air vent pointing down and rotate clockwise to lock in place Fits most wide mouthed bottles like Nalgene Classic LED Indicator Guide LED Color amp Pattern Indication Operating Signals EHEHEHE Armed ready for treatment mm 1 L Treatment successful 0 5 L Treatment successful Treatment activation timed out Press button to re activate aa Wet sensors Dry water sensors and re activate Treatment incomplete Classic lost detection of the water Treat again before consuming Battery Warnings Dead battery 1L treatment successful but battery is low 0 5L treatment successful but battery is low Check or recharge batteries Lamp Warnings E g iz lt 100 treatments remaining Lamp failure If LED indicators show normal signals but lamp does not activate lamp has failed Do not consume Tips for Safe Use e When operating properly the UV lamp will emit visible light as well as UV light If the lamp is not emitting visible light it is not functioning properly and should not be used until it has been repaired Agitation of water by stirring Classic or rocking the container is necessary as it promotes uniform purification e Classic is not intended to disinfect water above the surface of the water in the container such as droplets on the sides of the container e Classic is not intended t
6. ed in the USA with further U S patents pending and patents pending worldwide SteriPEN is a registered trademark of Hydro Photon Inc U S Patent Numbers 5 900 212 amp 6 110 424 amp 6 579 495 Compliance testing of SteriPEN Classic for the CE mark and ETL logo was successfully completed by Intertek Conforms to IEC 61010 1 2001 2nd Ed EN 61010 1 2001 2nd Ed including deviations to CAN CSA C22 2 No 61010 01 04 and UL 60950 1 2004 2nd Ed Water Quality Association SteriPEN tested and Gold Seal certified by WQA against U S EPA Microbiological Water Purifier Standard The Fine Print Directions for Use 40 C F R 156 10 i 2 It is a violation of Federal law to use this product in a manner inconsistent with its labeling 40 C FR 156 10 i 2 ii SteriPEN exceeds U S EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers destroying over 99 9999 of bacteria 99 99 of viruses and 99 9 of protozoa when used as directed SteriPEN is not a sterilizer Limited Lifetime Warranty for any manufacturing defect For product registration and complete warranty information please visit www steripen com warranty or contact your local distributor While carefully controlled microbiological testing of Classic has been conducted use in the field may produce results that vary from our laboratory test data This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num
7. mild soap solution Rinse soap from device and dry witha clean soft cloth If Classic s bulb is cracked chipped or damaged don t use it Return it to the store or contact us for repair Email us at support steripen com or call us at 1 888 826 6234 for help Do not try to fix it yourself Using the Pre Filter Step 1 Screw Pre Filter onto bottle Insert cartridge and pull blue air vent open Step 2 Filter water Pour through or submerge bottle until filled Step 3 Remove cartridge and purify Activate Classic then insert into Pre Filter and invert bottle For best results wet filter cartridge before filling to improve water flow Rub the mesh with a clean cloth until it becomes thoroughly saturated Remove Pre Filter before drinking Air vent is not intended for use as a mouthpiece Classic does not treat water droplets on the Pre Filter s body or threads Be sure to wipe dry any wet surfaces before drinking Frequently Asked Questions Get in touch We are always happy to hear from you visit www steripen com email info steripen com or call 1 888 826 6234 How many treatments can I expect to get With disposable lithium batteries you can expect around 100 full liter treatments NiMH rechargeable batteries with 2300MAh capacity will provide around 80 full liter treatments Be sure to always use quality batteries and never use alkaline batteries It looks like the tip of Classic s lamp is melting
8. ntact your local waste disposal organization e Classic is not intended to treat liquids other than water Do not use UV lamp as a light source e Do not use near skin eyes or insert into bodily orifices e Do not use in water above 120 F 49 C e Do not use in water with ice e As with any other water treatment system always have a backup method e While carefully controlled microbiological testing of all SteriPEN products has been conducted use of all SteriPEN products in the field may produce results that vary from our laboratory test data e Do not use in any manner other than instructed in this User s Guide Care amp Cleaning While Classic s battery compartment is designed to be highly water resistant it is not waterproof Avoid submerging Classic s battery end in water Classic s performance may be adversely affected by cold weather In temperatures below 32 F 0 C carry the unit close to your body or warm up batteries before use If batteries are too cold Classic s LED indicator may give low battery signal Warm up batteries and treat again Make sure to wipe dry after each use When not in use Classic should be kept in a safe place that is clean and dry It should not be exposed to temperatures above 120 F 49 C or below 4 F 20 C Also when storing for long periods of time remove batteries to keep them from inadvertantly draining To clean Classic wash with a soft cloth and a
9. o disinfect surfaces of a drinking container like the mouth of the bottle Be certain that you always wipe the bottle s mouth dry with a clean dry cloth before drinking e Classic is intended for use and is most effective in clear water but can also be used to treat turbid murky or cloudy water in an emergency By doubling treatment time treating the volume of water twice Classic can treat water that might be described as much closer to clear than opaque obviously not clear obviously cloudy objects viewed through the water are visible but blurry or as Cloudy as weak lemonade If the water is less clear filter it first with the SteriPEN PreFilter FitsAll Filter or other method for best UV purification results e Classic may be used in glass plastic ceramic or metal containers as they all absorb or reflect UV light thereby shielding the user from UV exposure e Classic is not intended for use by children e Classic is a high voltage device Removal or tampering with the electronic circuit board or lamp assembly may cause injury or damage e Do not open expose modify or touch internal circuitry doing so can lead to high voltage shock e Do not attempt to bypass water sensor it is an important safety feature e As with other fluorescent type lamps Classic contains a small amount of mercury At the end of its life please dispose of Classic properly For specific instructions co