Home

MyBioSource.com

image

Contents

1. Qualitative Chicken Influenza A Virus Subtype H5N1 Antigen H5N1Ag ELISA Kit Cat No MBS9311007 Store All Reagents At 2 C 8 C Package Size 48T Kit or 96 T Kit Valid Period Six Months 2 C 8 C IN VITRO RESEARCH USE ONLY NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS 1 INTENDED USE For the qualitative determination of activated Chicken Influenza A Virus Subtype H5N1 Antigen H5N1Ag in serum plasma tissue homogenate cell culture supernates and other biological fluids 2 PRINCIPLE OF THE ASSAY The kit uses a double antigen sandwich enzyme linked immunosorbent assay ELISA to analyze the existence or not of Chicken H5N1Ag in samples Add sample to wells pre coated with one Chicken Influenza A Virus Subtype HSN1 antibody at same time add HRP conjugated Chicken Influenza A Virus Subtype H5N1 antibody to bind the analyte followed by incubation and washing procedures to remove unbound substance Finally HRP substrates are added incubated for detection and a blue color is developed Reaction is stopped and color turns to yellow when Stopping Solution acidic is added The existence or not of Chicken HSN1Ag in the samples is then determined by comparing the O D of the samples to the CUT OFF 3 SAMPLE COLLECTION AND STORAGES Serum Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4 C before centrifugation for 20 minutes at approximately 2000xg Remove serum and assay
2. immediately or aliquot and store samples at 20 C Avoid repeated freeze thaw cycles Plasma Collect plasma using EDTA or heparin as an anticoagulant Centrifuge samples for 30 minutes at 2000xg at 2 8 C within 30 minutes of collection Store samples at 20 C Avoid repeated freeze thaw cycles Tissue homogenate and other biological fluids Remove particulates by centrifugation and assay immediately or aliquot and store samples at 20 C Avoid repeated freeze thaw cycles 4 Sample preparation Typically serum plasma and other biological fluids samples do not require dilution If samples generate values higher than the highest standard please dilute the samples with Sample Diluent and repeat the assay Notes Serum and plasma to be used within 7 days may be stored at 2 8 C otherwise samples must be stored at 20 or 80 C to avoid loss of bioactivity and contamination Avoid freeze thaw cycles When performing the assay slowly bring samples to room temperature The samples shoule be 1 4 FOR RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES centrifugated dequately and no hemolysis or granule was allowed 5 REAGENTS PROVIDED All reagents provided are stored at 2 8 C Refer to the expiration date on the label Items Materials 96 Tests 48 Tests 1 Microelisa stripplate 12 8strips 12 4strips 2 Positive Control 0 5ml vial 0 5ml vial 3 Negative Control 0 5ml via
3. able for 1 month at 2 8 C 10 ASSAY PROCEDURE 1 First secure the desired number of coated wells in the holder Remove excess microplate strips from the plate frame return them to the foil pouch containing the desiccant pack and reseal 2 Set Positive Control wells Negative Control wells and testing sample wells on the assay plate strip Add Positive Control 50ul then add Negative Control 50ul to corresponding wells Add testing sample 10ul then add Sample Diluent 401 to testing sample wells 3 Add 100ul of HRP conjugate reagent to standard wells and sample wells except the blank well cover with an adhesive strip and incubate for 60 minutes at 37 C 4 Wash the Microtiter Plate 4 times See WASHING METHOD 5 Add chromogen solution A 50ul and chromogen solution B 50ul to each well Gently mix and incubate for 15 minutes at 37 C Protect from light 6 Add 50ul Stop Solution to each well The color in the wells should change from blue to yellow If the color in the wells is green or the color change does not appear uniform gently tap the plate to ensure thorough mixing 7 Read the Optical Density O D at 450 nm using a microtiter plate reader within 15 minutes 11 DETERMINE THE RESULT 1 Test validity the average of Positive control well 1 00 the average of Negative control well lt 0 15 2 Calculate Critical CUT OFF Critical the average of Negative control well 0 15 3 Negative Result sample OD lt Calculate C
4. atches 10 Stop Solution should be added in the same order of the Substrate solution 11 Chromogenic Substrate B is light sensitive please avoid prolonged exposure to light 2 4 FOR RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES 12 The kit should be kept at 2 8 C and cannot be used after expiration date The standards should be kept at 20 Cafter receiving 8 WASHING METHOD Manual Washing Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container Using a squirt bottle fill each well completely with Wash Solution 1X then aspirate contents of the plate into a sink or proper waste container Repeat this procedure for a total of four times After final wash invert plate and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears Note Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame Automated Washing Aspirate all wells then wash plates four times using Wash Solution 1X Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350uL well wash After final wash invert plate and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears 9 REAGENT PREPARATION AND STORAGE Wash Solution 1X Dilute 1 volume of Wash solution 20X with 19 volumes of deionized or distilled water Wash Solution is st
5. l 0 5ml vial 4 Sample diluent 6 0ml 3 0ml 5 HRP Conjugate reagent 10ml 5 0ml 6 20X Wash solution 25ml 15ml 7 Chromogen Solution A 6 0ml 3 0ml 8 Chromogen SolutionB 6 0ml 3 0ml 9 Stop Solution 6 0ml 3 0ml 10 Closure plate membrane 2 2 11 User manual 1 1 12 Sealed bags 1 1 6 MATERIALS REQUIRED BUT NOT SUPPLIED 1 Standard microplate reader capable of measuring absorbance at 450 nm 2 Automated Washing 3 37 C incubator 4 Clean tube and Eppendorf tube 5 Distilled or deionized water 6 Precision pipettes disposable pipette tips multi channel pipettes and Absorbent paper 7 PRECAUTIONS 1 The operation should be carried out in strict accordance with the provided instructions 2 To preserve unused strip wells it should be stored in the sealed bag 3 Always avoid foaming when mixing or reconstituting protein solutions 4 Pipette reagents and samples into the center of each well 5 The samples should be transferred into the assay wells within 15 minutes of dilution 6 We recommended that all standard testing samples are tested in duplicate to minimize the test errors 7 If the blue color too shallow after 15 minutes incubation with the substrates it may be appropriate to extend the incubation time 8 Avoid cross contamination by changing tips using separate reservoirs for each reagent avoid using the suction head without extensive wash 9 Do not mix the reagents from different b
6. ritical CUT OFF is Negative 4 Positive Result sample OD gt Calculate Critical CUT OFF is Positive 12 ASSAY CHARACTERISTICS 1 Intra assay CV and Inter assay CV are less than 15 2 Cross reactivity This assay recognizes recombinant and natural Chicken H5N1Ag No 3 4 FOR RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES significant cross reactivity or interference was observed 3 Storage 2 8 C Use frequently six months 20 C 4 4 FOR RESEARCH USE ONLY NOT FOR USE IN DIAGNOSTIC OR THERAPEUTIC PROCEDURES

Download Pdf Manuals

image

Related Search

MyBioSource.com mybiosource.com mybiosource.com scholarship

Related Contents

IMPORT ANTE G  300468 300753 Aguarras Simil Limon SPB  Elektropneumatische Kontrolleinheit ELKE 24/2F  phytoépuration  body and special equipment installation precautions  iStarUSA DAGE1040T7-PM computer case  Prewiring manual micro v4 series enrev2  as a PDF  事業仮契約書(案)(修正版) (PDF 201.6KB)  Operators(2)  