FUJITSU Server PRIMEQUEST 2000 Series Message Reference

image

Contents

1. Reconfiguring partition 4 5 Meaning The reconfiguration of the partition is executed Corrective action No action is necessary Onlining added Memory CPU 5 5 Meaning The onlining of Memory CPU is executed Corrective action No action is necessary DR operation start 1 3 Meaning DR operation of IOU is started Corrective action No action is necessary Assigning IOU to partition 2 3 Meaning The allocation to the partition is executed Corrective action No action is necessary 146 CA92344 0540 05 MMB Messages Power on IOU 3 3 Meaning The power of IOU is turned on Corrective action No action is necessary DR feature is disabled Meaning DR command cannot execute because DR function of the specified partition is disabled Corrective action Please enable DR function of specified partition Unable to execute DR command while other DR command is running Meaning The specified partition cannot execute DR command while other DR command is running Corrective action Please do the following operation after completing the DR process of the specified partition Unable to execute DR command because OS is not ready for DR operation Meaning The DR command cannot execute because OS of the specified partition is not ready Corrective action Please wait for OS booting In case of OS running please confirm OS supports the DR function and the method of installing OS is correct
2. 12453 Adapter error POST timeout Meaning Adapter failed the power on self test Corrective action Reboot the Partition If the error keeps recurring replace the adapter Severity Warning 12454 Adapter error Unrecoverable error detected in the adapter Meaning Unrecoverable error occurred in the adapter Corrective action Reboot the Partition If the error keeps recurring replace the adapter Severity Warning 12455 Adapter error Please upgrade firmware Meaning Upgrade of firmware is needed Corrective action Update firmware to version 4 0 or later Severity Warning 12551 Adapter error hwi init controller failed Driver init Meaning Init error is occerred in the driver Firmware is not exist or not running Corrective action Replace the HBA Severity Warning 12552 Adapter error EEH error detected Meaning Drive PCI error has occurred PCle error is detected on the system Corrective action Replace the HBA Severity Warning 87 CA92344 0540 05 MMB Messages 12553 Adapter error EEH State PERM Failure Meaning Drive PCI error has occurred PCle error is not recovered Corrective action Replace the HBA Severity Warning 12554 Adapter error Initialization Failure Meaning Firmware is not exist or not running It might be a Hardware problem Corrective action Replace the HBA Severity Warning 12555 Adapter error Initialization failu
3. As skipping the power on operation does not affect the maintenance work Review the partition configuration Severity Warning 00213 aa cannot be executed because the system is under maintenance Meaning aa cannot be performed during maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info 00214 Unable to Power On the Partition aa because this Partition is under maintenance Meaning Power to partition aa cannot be turned on because maintenance is in progress Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info W 00214 Unable to power on the Partition aa due to CPU mismatch between SBs After checking SB status and configuration please come back to the Replacement Instruction Window and reinstall the unit Meaning During the power on process of partition aa in SB Warm System Maintenance the power to the partition could not be turned on because of mismatching CPUs between the SBs Corrective action Different CPUs have been mixed Check if there is any problem in the replaced CPU in the currently displayed window Return to the replacement instruction window and execute the replacement process again Severity Warning 165 CA92344 0540 05 MMB Messages 00215 There is a possibility that other users are using this aa Are you sure Meaning aa may be used by anothe
4. Info 4 CA92344 0540 05 MMB Messages 2 1 2 018107FF Upper Non critical going high Deassert C threshold C Meaning High temperature warning was canceled Corrective action No action is necessary Severity Info 018109FF Upper Critical going high Deassert C threshold C Meaning High temperature error was canceled Corrective action No action is necessary Severity Info 01810BFF Upper Non recoverable going high Deassert C threshold C Meaning High temperature error Ultra high level processing was canceled Corrective action No action is necessary Severity Info Voltage Sensor Related Voltage Sensor related messages are listed below 020100FF Lower Non critical going low Assert V threshold V Meaning Low voltage warning has occurred Corrective action Target board must be replaced Severity Warning 020102FF Lower Critical going low Assert V threshold V Meaning Low voltage error has occurred Corrective action Target board must be replaced Severity Error 020104FF Lower Non recoverable going low Assert V threshold V Meaning Low voltage error has occurred Corrective action Target board must be replaced When Unit in SEL is SB xx identify the replacement parts by referring to TABLE A 2 Replacement component list 2 Severity Error 5 CA92344 0540 05 MMB Messages 020107FF
5. MMB Messages 2 1 20 Maintenance mode related The messages related to the maintenance mode are listed below CC6FOOFF Enter Hot Maintenance Meaning The hot maintenance mode is activated Corrective action No action is necessary Severity Info CC6F01FF Enter Partition Maintenance In case PRIMEQUEST 2400E2 2800E2 2400E 2800E Enter Hot Maintenance In case PRIMEQUEST 2800B2 2800B Meaning The partition maintenance mode is started Corrective action No action is necessary Severity Info CC6F02FF Enter Cold Maintenance Meaning The system maintenance mode is started Corrective action No action is necessary Severity Info CCEFOOFF Exit Hot Maintenance Meaning The hot maintenance mode is ended Corrective action No action is necessary Severity Info CCEFO1FF Exit Partition Maintenance In case PRIMEQUEST 2400E2 2800E2 2400E 2800E Exit Hot Maintenance In case PRIMEQUEST 2800B2 2800B Meaning The partition maintenance mode is ended Corrective action No action is necessary Severity Info CCEFO2FF Exit Cold Maintenance Meaning The system maintenance mode is ended Corrective action No action is necessary Severity Info 73 CA92344 0540 05 MMB Messages 2 1 21 Power Saving related The messages related to the power saving are listed below CD6F01FF Power Saving Started Meaning The power is actually saved by power saving function The perfo
6. Severity Warning Failed to execute add partition command Meaning Add partition command process has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error Are you sure you want to remove s from Partition d Y N Meaning Check whether to remove the SB IOU or Extended Partitioning from the partition Corrective action No action is necessary Severity Info Removing s from Partition d has been completed successfully Meaning The SB IOU or Extended Partitioning has been removed from the partition normally Corrective action No action is necessary Severity Info Partition x does not include the SB x IOU Zx Extended Partitioning x Meaning The specified SB IOU Extended Partitioning is not included in Partition x In the execution of the set partition home command only the SB pattern emerges Corrective action Confirm that the SB IOU Extended Partitioning is correctly specified Also confirm the partition configuration Severity Warning Unable to remove the specified SB x IOUZx Extended Partitioning x from the partition while the partition is running Meaning The SB IOU or Extended Partitioning cannot be removed while the partition is running Corrective action Stop the partition before starting an operation Severity Warning Parameter missing Meaning A required parameter i
7. This operation is prohibited Corrective action SB hot plug operation via DR command is not allowed Please do SB hot plug via MMB UI 198 CA92344 0540 05 Dynamic Reconfiguration Messages dr util ERR d lt x gt invalid device is set d 210 214 Meaning x is not a device that can be specified with add Corrective action The invalid device for add operation was set to the argument Please review the command argument and execute the command again dr util ERR d x invalid device is set d 215 219 Meaning x is not a device that can be specified with rm Corrective action The invalid device for rm operation was set to the argument Please review the command argument and execute the command again dr util ERR d x invalid device is set 96d 220 224 228 Meaning x is not a device that can be specified with show Corrective action The invalid device for show operation was set to the argument Please review the command argument and execute the command again dr util ERR d x invalid device is set d 225 227 Meaning x is not a device that can be specified with stat Corrective action The invalid device for stat operation was set to the argument Please review the command argument and execute the command again dr util ERR 230 SB d invalid device is set Meaning SB d is not the SB device that can be removed d represents the SB number
8. Title Description Manual code PRIMEQUEST 2000 Series Describes REMCS service installation and operation CA92344 0542 REMCS Installation Manual PRIMEQUEST 2000 Series Defines the PRIMEQUEST 2000 series related terms and CA92344 0541 Glossary abbreviations Related manuals The following manuals relate to the PRIMEQUEST 2000 series You can access these manuals at the following site http www fujitsu com global services computing server primequest htto manuals ts fujitsu com Contact your sales representative for inquiries about the ServerView manuals Title Description ServerView Suite ServerView Operations Describes how to install and start ServerView Operations Manager in a Manager Quick Installation Windows Windows environment ServerView Suite ServerView Operations Describes how to install and start ServerView Operations Manager in a Linux Manager Quick Installation Linux environment ServerView Suite ServerView Installation Describes the installation procedure using ServerView Installation Manager Manager ServerView Suite ServerView Operations Provides an overview of server monitoring using ServerView Operations Manager Server Management Manager and describes the user interface of ServerView Operations Manager ServerView Suite Server View RAID Describes RAID management using ServerView RAID Manager Management User Manual ServerView Suite Basic Concepts Describes basic conc
9. Unable to execute DR command due to previous failure Meaning DR command cannot execute because the error occurred by the DR processing before Corrective action Please turn off the power of specified partition and turn on it again The specified SB x IOU x is not free or reserved Meaning The specified SB IOU has been built into another partition Corrective action Please confirm configuration of partition Unable to hot add SB due to CPU mismatch Meaning Hot add cannot execute because the kind of CPU on specified SB is different from the kind of CPU of the specified partition Corrective action Please confirm SB number If the kind of CPU on specified SB is different from the kind of CPU of the specified partition exchange CPU of specified SB Unable to hot add SB due to DIMM mismatch Meaning Hot add SB cannot execute because the configuration of DIMM on specified SB Corrective action Please confirm SB number and the configuration of DIMM If the kind of DIMM on specified SB is different from the kind of DIMM of the specified partition exchange CPU of specified SB Please make the number of DIMM on the specified SB and the number of DIMM on Home SB of specified partition the same number 147 CA92344 0540 05 MMB Messages Unable to hot add SB due to firmware mismatch Meaning Hot add SB cannot execute because the firmware version on specified SB is invalid or under updating of firmware Corrective
10. Warning 1BEFOOFF Cable is not connected Meaning The IOU cable is not connected Corrective action No action is necessary Severity Info C8A20100 Fatal Internal error Meaning PCI card error was detected Corrective action PCI card must be replaced If the error is uncorrectable the IOU SB DU or PCI Box containing the PC card must be replaced Severity Error 2 1 10 Subsystem related Subsystem related messages are listed below 1507071A Boot Retry Meaning As Heartbeat Lost was detected when the power was turned on rescue retry was performed Corrective action No action is necessary Severity Info 280300A0 BMC Firmware Error Meaning BMC firmware error has occurred Corrective action The system board must be replaced If the error persists the Active MMB must be replaced Severity Warning 24 CA92344 0540 05 MMB Messages 280300C0 BMC MMB LAN Failure Meaning Error was detected in the communication with the BMC during the Private LAN monitoring Corrective action The system board must be replaced If the error persists the active MMB must be replaced Severity Warning 280701C0 BMC MMB LAN Error Meaning Error was detected in the communication with the BMC during the Private LAN monitoring Corrective action The system board must be replaced If the error persists the active MMB must be replaced Severity Warning 280703C0 BMC MMB LAN Failure Meani
11. Watchdog timer has timed out For the operation to be performed after the expiration of the Watchdog timer the operation specified by the ASR Automatic Server Restart Control would be prioritized if the number of retries specified by ASR Control has been exceeded Corrective action Please check the setting of Boot Disk or Boot Device because OS loader is abnormal behavior If there is not any problem download the system event log and contact your sales representative or a field engineer Severity Error B0236FFF Watchdog Action Power Down Meaning Watchdog timer has timed out For the operation to be performed after the expiration of the Watchdog timer the operation specified by the ASR Automatic Server Restart Control would be prioritized if the number of retries specified by ASR Control has been exceeded Corrective action Please check the setting of Boot Disk or Boot Device because OS loader is abnormal behavior If there is not any problem download the system event log and contact your sales representative or a field engineer Severity Error B0236FFF Watchdog Action Hard Reset Meaning Watchdog timer has timed out For the operation to be performed after the expiration of the Watchdog timer the operation specified by the ASR Automatic Server Restart Control would be prioritized if the number of retries specified by ASR Control has been exceeded Corrective action Please check the setting of Boot D
12. 130 CA92344 0540 05 MMB Messages The specified IP address is invalid Meaning The specified IP address is invalid Corrective action Check the command parameter Severity Warning The specified IP address is duplicated Meaning The specified IP address is already registered This IP address cannot be registered Corrective action Check the command parameter Severity Warning The specified IP address is loopback address Meaning A loop back address has been specified This IP address cannot be registered Corrective action Check the command parameter Severity Warning The specified netmask is invalid Meaning The specified netmask is invalid Corrective action Check the command parameter Severity Warning The specified port number is invalid Meaning The specified port number is invalid Corrective action Check the command parameter Severity Warning The specified port number is duplicated Meaning The specified port number is already registered This port number cannot be registered Corrective action Check the command parameter Severity Warning The specified hostname is invalid Meaning An invalid host name has been specified Corrective action Check the command parameter Severity Warning Unable to change the home SB while the partition is running Please try to change the home SB after the partition is shutdown Meaning The Home SB cannot be changed
13. 143 CA92344 0540 05 MMB Messages Unable to change the mode while the parent PPAR partition is running Please try to change the mode after all Extendeding partitions on the same parent PPAR partition are shutdown Meaning This process cannot be executed for a parent PPAR partition which is powered on Corrective action Check the power status of the parent PPAR partition of the processing target partition Severity Warning Unable to execute this command because Extended Partitioning mode of the parent PPAR partition of this Extended Partitioning Partition x is not enabled Meaning This process cannot be executed since the Extended Partitioning mode of the parent PPAR partition is not Enable Corrective action Check the parent PPAR partition Extended Partitioning mode of the processing target partition Severity Warning Unable to set configuration because this Extended partition is powered on Meaning Unable to change the Extended Partition configuration because the partition is the powered on status Corrective action Change the Extended Partition configuration after turning off the partition power of the partition Severity Warning The specified CPU Cores Memory USB1 VGA USB2 PCI Slot is not free Meaning The specified CPU Cores Memory USB11IVGA USB2I PCI Slot is already included in the Partition Corrective action Check if there is any error in the CPU Cores Memory USB 1IVGA
14. CPU SB or Memory Scale up Board must be replaced Contact your sales representative or a field engineer Severity Error C8A20600 Fatal Internal error Meaning A Fatal CPU or Memory Scale up Controller error has occurred Corrective action CPU or Memory Scale up Board must be replaced Contact your sales representative or a field engineer Severity Error C8A20601 Fatal QPI Path error SB x CPU Y Meaning A Fatal error was detected in the QPI transmission path between the CPUs or Memory Scale up Controllers Maximum two CPUs or Memory Scale up Controllers that detected the error are specified in Corrective action CPU SB or Memory Scale up Board must be replaced Contact your sales representative or a field engineer Severity Error C8A706FF PRIMEQUEST 2400E2 2800E2 2800B2 only Correctable error logging limit reached Meaning Correctable errors have occurred frequently and have reached the replacement threshold Corrective action CPU or Memory Scale up Board must be replaced Contact your sales representative or a field engineer Severity Warning C8A90602 QPI lane degraded Meaning Lane degradation was detected in the QPI Port Corrective action The target CPU SB or Memory Scale up Board must be replaced Contact your sales representative or a field engineer Severity Warning 51 CA92344 0540 05 MMB Messages 2 1 16 C8A90602 SMI2 lane degraded Meaning Lane deg
15. Corrective action Make sure that the CPU mounted on the SB configuring the partition is the same as the CPU mounted on the SB to be included in the partition Severity Error E 00113 Unable to register the specified SB aa as a Reserved SB due to CPU mismatch between SBs Meaning SB aa cannot be registered because there is mismatch of CPUs that are mounted between the SBs Corrective action Make sure that the CPU mounted on the SB configuring the partition is the same as the CPU to be mounted on the Reserved SB Severity Error E 00114 The specified SB aa cannot be registered as a Reserved SB The specified SB aa cannot be registered as a Reserved SB Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error 160 CA92344 0540 05 MMB Messages E 00123 Failed to clear the status Meaning Status clearing has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error E 00125 Failed to aa Meaning aa operation has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error 00126 Unable to reset Maintenance Mode from the Enter Maintenance Mode Please release Maintenance Mode if you still want to proceed Meaning The maintenance mode cannot be reset during maintenance Continue t
16. DR process is failed with BIOS Error Code Corrective action Case 1 Partition is operating and SEL is logged action Please process it according to SEL Case 2 Partition is operating and SEL is not logged action 1 Download SEL and contact your sales representative or a field engineer 2 Please turn off the power of specified partition and turn on it again 3 Please process it according to SEL if power off on of the partition is failed Please use it continuously if power off on of the partition is success Case 3 Partition is reset action 1 Download SEL and contact your sales representative or a field engineer 2 Please process it according to SEL if reset of the partition is failed Please use it continuously if reset of the partition is success The specified SB is home SB Meaning The specified SB cannot remove because it is Home SB in the partition Corrective action Please confirm configuration of partition The specified SB lOU is not in specified Partition Meaning The specified SB cannot remove because it is not constituent of the partition Corrective action Please confirm configuration of partition Hot remove SB lOU failed Meaning Hot remove SB IOU was failed because an error occurred Corrective action Please process it according to other message Failed to execute DR operation Configuration is unrecovered Meaning DR operation was failed and the configuration of hardwa
17. SecureBoot isn t configured correctly Meaning Configuration of Secure boot is incorrect There is Boot Device or OS loader which is not supported Secure Boot in partition Or the Key or the DB for Secure Boot is deficient in UEFI Corrective action Please check Device and the setting of UEFI Severity Warning B013101 h Poisoned Data Consumed Meaning Incorrect data that is generated by previous hardware error is used by software Whether operation of the partition stops or continues depends on type of OS or state in using the invalid data Corrective action The message of hardware error was logged before this message Replace unit identified by the message of hardware error Severity Warning uSystem Event related BMC B0128200 No usable CPU Meaning No CPU is installed Corrective action Mount the CPU Severity Error mChip set related BMC B0196001 iRMC Flash PROM Boot SPI access failure Meaning An SPI Bus error has occurred Corrective action Replace the SB Severity Error B0196002 BIOS PROM Host SPI access failure Meaning An SPI Bus error has occurred Corrective action Replace the SB Severity Error B0196003 NVRAM Backup SPI access failure Meaning An SPI Bus error has occurred Corrective action Replace the SB Severity Error 31 CA92344 0540 05 MMB Messages B0196004 l2C EEPROM access failure Meaning An error occurred in BM
18. The IOC message unit reset process failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13009 Adapter error pci resume Cannot recover Meaning A resume operation on the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13011 Adapter error Adapter not ready Meaning The adapter does not become READY Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13012 Adapter error Adapter not ready Meaning The adapter does not become READY alt port Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13014 Adapter error init failure Meaning Sending an lOCInit request to the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13018 Adapter error Unexpected doorbell active Meaning An unexpected active state of the adapter was detected Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity
19. s Disk enclosure model name e g JX40 Meaning SSD Rated Write Endurance has reached 90 Corrective action Replace the SSD Severity Info 76 CA92344 0540 05 MMB Messages E76F0909 SSD Rated Write Endurance has reached 90 Meaning SSD Rated Write Endurance has reached 90 Corrective action Replace the SSD Severity Info 2 2 List of SVAS message IDs This section lists the messages related to the SVAS SVAS outputs the log to SEL of MMB in the following either event ID detecting the message of the device driver BC507000 BC508000 BC509000 BC547000 BC548000 BC549000 Message ID is included in the output log and the action is executed according to the following message ID list Please confirm details of the message that the device driver output by the event log of OS 2 2 1 Linux related LAN FC Linux related 11001 Adapter error should not be a VF Meaning An invalid VF device ID was set for PCle SR IOV capability Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11601 Adapter error The NVM Checksum Is Not Valid Meaning An NVM checksum error was detected Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11602 Adapter error Hardware Error Meaning A hardware error was detected Corrective action An adapter failure may have occurred Replace the a
20. 13026 Adapter error Can t get OCFacts IOC NOT READY Meaning The PORTFACTS request cannot be executed because the adapter is in the NOT READY state Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13027 Adapter error Wait IOC OP state timeout Meaning The state did not change to IOC OP even after a wait for the specified time 60 seconds Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 90 CA92344 0540 05 MMB Messages 13028 Adapter error Failed to come READY after reset Meaning The state did not change to READY even after a wait of 20 seconds after adapter reset Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13029 Adapter error Enable Diagnostic mode FAILED Meaning The adapter did not enter diagnostic mode even after 20 retries Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13031 Adapter error ResetHistory bit failed to clear Meaning The ResetHistory bit of the adapter could not be cleared Corrective action The HBA must be replaced If the error keeps recurring contact your sales
21. 19002 Adapter error Write operations disabled 800GB card Meaning Write operations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19003 Adapter error Write operations disabled 800GB card Meaning Write operations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19004 Adapter error Memory is close to wearing out 800GB card Meaning The product lifetime end for write operation will come soon If the device is still used it will be switched to the Read Only mode and then the data will NOT be written to the device anymore Corrective action Replace the PCle SSD card to the new one which is already purchased Severity Info 19005 Adapter error Reliability degraded 800GB card Meaning The reliability is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19006 Adapter error Temperature above warning threshold 800GB card Meaning Temperature has exceeded the upper warning threshold Corrective action Reduce the load of writing operations Check the ambient temperature a
22. Adding SB IOU to Partition Z Failed Meaning Adding of SB IOU is failed Corrective action Please deal with it according to other messages output at the same time Removing SB lIOU from Partition Z Failed Meaning Removing of SB IOU is failed Corrective action Please deal with it according to other messages output at the same time Unable to execute power control because the firmware is updating Meaning Power control cannot execute because the firmware is updating Corrective action Wait for completing of firmware update Unable to execute command because the power control operating Meaning Command cannot execute because the power control is operating Corrective action Wait for completing of power control operation The specified MMB IP address is duplicated Console IP Address Meaning MMB IP address is duplicated by Console IP Address Corrective action Change the IP Address The specified MMB IPv6 address is duplicated Console IP Address Meaning MMB IP address is duplicated by Console IP Address Corrective action Change the IP Address Unable to set Extended Partitioning Mode because Power Save Control is enabled Meaning Extended Partition Mode is unable to set because Partition Power Save Control is enabled Corrective action Check the Partition Power Save Control settings 151 CA92344 0540 05 MMB Messages 2 4 CAUTION Assignment of VGA USB2 rKVMS
23. After Maintenance completion Check the System Event Log Window to refer to the error details Meaning The aa firmware update process has terminated abnormally Corrective action This window is displayed again when the OK button is clicked Execute the firmware update process again If the same event recurs complete the replacement work and then check the system event log Severity Warning E 00301 Maintenance cannot be continued because PSU could not be powered off Check the System Event Log Window to refer to the error details Meaning PSU power off process executed during PSU replacement in Hot System Maintenance has terminated abnormally Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error 172 CA92344 0540 05 MMB Messages E 00302 Maintenance cannot be continued because PSU could not be powered on Check the System Event Log Window to refer to the error details Meaning The PSU power on process that was executed when returning to the previous window by clicking the Previous button in PSU replacement of the Hot System Maintenance has terminated abnormally Corrective action The completion window appears when Ok in the dialog box is clicked Check the system event log for any errors If t
24. Check the ambient temperature and reduce the write load Severity Warning 28721 Adapter error Temperature above error threshold Meaning The temperature has exceeded the error threshold Corrective action Check the ambient temperature and reduce the write load Severity Warning 28722 Adapter error Internal voltage out of range Meaning The internal voltage is outside its range Corrective action If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28723 Adapter error Auxiliary voltage out of range Meaning The auxiliary voltage is outside its range Corrective action If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28724 Adapter error Flashback error Meaning A flashback error occurred Corrective action 1 Back up the data from the affected adapter 2 Replace the adapter 3 Restore the data Severity Warning 118 CA92344 0540 05 MMB Messages 28725 Adapter error Non correctable PCI errors detected Meaning An uncorrectable PCI error was detected Corrective action If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28726 Adapter erro
25. Corrective action Failed to remove SB because OS kernel uses the memory on SB to be removed Please confirm if SB to be removed is correct dr util ERR d s Invalid argument d 240 245 249 Meaning Invalid argument Corrective action Invalid argument was specified Please review the command argument and execute the command again dr util ERR 926d s Invalid argument d 246 248 Meaning Invalid argument Corrective action Invalid argument was specified Please review the command argument and execute the command again dr util ERR 260 s invalid subcommand is set Meaning Invalid argument Corrective action Invalid argument was specified Please review the command argument and execute the command again dr util ERR 270 None device is not set Meaning device is not set Corrective action Invalid argument was specified Please execute the command again with specifying device name 199 CA92344 0540 05 Dynamic Reconfiguration Messages dr util ERR 280 cpu lt x gt device is already available Meaning cpu lt x gt is already available Corrective action cpu lt x gt is already available No action is necessary dr util ERR 280 memory lt x gt device is already available Meaning memory lt x gt is already available Corrective action memory lt x gt is already available No action is necessary dr util ERR 281 PCle lt x gt device is already available Mean
26. Meaning User aa will be added The message asks for confirmation to continue processing Corrective action No action is necessary Severity Info 00411 aa will be changed Are you sure Meaning User aa will be changed The message asks for confirmation to continue processing Corrective action No action is necessary Severity Info E 00412 You need an empty entry Meaning Add was specified but further schedules cannot be registered Displayed when a schedule is added when the registered schedule data has reached the upper limit of registration Action Delete unnecessary schedules Severity Error 176 CA92344 0540 05 MMB Messages W 00413 Nothing is selected Meaning The operation target has not been specified Corrective action Select the target Severity Warning W_00414 Invalid Date Format Meaning An invalid date has been specified Corrective action Check the date Severity Warning W_00415 The duplicate On Off Time is found Meaning The same time has been specified for On Time and Off Time Corrective action Check the On Time and Off Time Severity Warning W_00416 Both On Off Time are disabled Meaning Start and stop time have not been entered Corrective action Enter the start stop time Severity Warning 00417 Are you sure Meaning The message asks for confirmation to continue processing Corrective action Contin
27. Replace the RAID Card Severity Error C8A70D00 RAID Card Unable to recover cache data due to configuration mismatch VendorlD 04x DevicelD 04x SubvendorlD 04x Subsystem 04x on IOU_ dGbE Meaning RAID Card Unable to recover cache data due to configuration mismatch Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C8A70D01 RAID Card Logical drives missing at boot VendorlD 04x DevicelD 04x SubvendorlD 04x Subsystem 04x on IOU_ dGbE Meaning RAID Card Logical drives missing at boot Corrective action Check the configuration of array If the problem persists please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C8A70D02 RAID Card Previous configuration completely missing at boot VendorlD 04x DevicelD 04x SubvendorlD 04x Subsystem 04x on IOU_ dGbE Meaning RAID Card Previous configuration completely missing Corrective action Check the configuration of array The message might be logged if all the disks which are configured logical drives are plugged out and a host is powered on To avoid the situation please clear logical drive configuration beforehand if you will plug out all the disks Severity Warning 60 CA92344 0540 05 MMB Messages C8A70D03 RAID Card SAS topology error VendorlD 04x D
28. cannot be changed if the Extended Partition is powered on Please release VGA USB2 rKVMS after the operation Note IP Address Video Redirection and Virtual Media for all Extended Partitions must be enabled in Partition gt Console Redirection Setup menu Meaning VGA USB2 rKVMs should be assigned to running Extended Partition If VGA USB2 rKVMs is assigned to running Extended Partition when you assign VGA USB2 rKVMS to other partition turn off the running Extended Partition Corrective action Set VGA USB2 rKVMs to free Window Display Error Messages This section lists the error messages displayed during Web UI operations and contains information on how to respond to them Note A message with a message ID may have a numerical value at the end of the message Example 00 0404 This numerical value indicates the detailed information If the problem cannot be resolved contact your sales representative or a field engineer and pass on the numerical value GUI messages and corrective actions are as follows 00001 Command Completed Meaning The e mail send test was successful Corrective action No action is necessary Severity Info E 00002 Command Failed Meaning Acquisition of the setting information has failed Corrective action Retry the process If it fails contact your sales representative or a field engineer Severity Error 00004 Not Logged in Meaning There is no
29. installation environment Severity Warning uProcessor related BMC B00700FF CPU CPU internal error IERR Meaning An error has occurred in the CPU Corrective action Replace the CPU Severity Error B00701FF CPU CPU thermal trip alert Meaning Abnormal CPU temperature error was detected Corrective action Replace the CPU Severity Error B00740FF CPU ZO CPU internal error IERR Meaning CPU error has occurred Corrective action Replace the CPU Severity Error 28 CA92344 0540 05 MMB Messages B00744FF CPUs CPU startup init failure disabled Meaning A CPU error has occurred Corrective action Replace the CPU Severity Error B0076100 CPUs CPU thermal trip alert deasserted Meaning Abnormal temperature was detected in the CPU Corrective action Replace the CPU Severity Error B0076101 CPU CPU thermal sensor error Meaning An error has occurred in the CPU temperature sensor Corrective action Replace the CPU Severity Error B0076500 CPU CPU Mismatch Meaning Same CPUs were not mounted Corrective action Check the CPU combination Severity Warning B0076501 CPUs Unsupported CPU Meaning An unsupported CPU is mounted Corrective action Check whether the CPU is supported or not Severity Warning B0076502 CPUZ Installed Position Condition Error Meaning There is violati
30. replace the device 3 Medium Error If it is a disk replace the device If it has removable media perform cleaning and replace the media 4 Hard Error Replace the device 5 Illegal Request Examine the software 6 Unit Attention This is notification information from various devices e g reset status RAID degradation if applicable 7 Data Protect Check the Write Protect status 8 Blank Check Check tape and other operations 9 Aborted Command Investigate problems in the SCSI bus and FC transmission paths If the problem persists contact your sales representative or a field engineer Severity Warning 14060 Device error Medium error or Volume overflow Meaning A media error or volume overflow occurred Corrective action Check operation If there is no problem in operations take the following corrective action Tape device Clean the device If the problem persists replace the media Disk device Replace the drive Severity Warning 14061 Device error SCSI command retry out Meaning A SCSI command terminated abnormally retry out Corrective action Identify the type of the target unit Then check the sense key extended sense in the original message to determine the corrective action 1 Recovered Error If it is a removable device perform cleaning 2 Not Reagy If it is non removable replace the device 3 Medium Error If it is a disk replace the device If it has removable medi
31. transmission path and target Aborted Command An HBA transmission path or target failure may have occurred Other than above Replace the drive Severity Warning 14018 Device error Stepping over filemark forward failed Meaning A tape fast forward or rewind error occurred on the device Corrective action If normal operation cannot be restored even after cleaning and tape replacement replace the drive Severity Warning 100 CA92344 0540 05 MMB Messages 14020 Device error Can t set default drive buffering mode Meaning A device error occurred Changing the tape drive buffering mode MODE_SELECT failed Corrective action Check whether the tape device supports the buffer value contained in the message If supported a hardware failure occurred Replace the drive Severity Warning 14022 Device error Error on write filemark Meaning A device error occurred The write file mark command failed Corrective action If normal operation cannot be restored even after cleaning and tape replacement replace the drive Severity Warning 14023 Device error Can t set default compression Meaning A device or setting error occurred The compression density could not be set to the default Corrective action If there is no problem with the settings of the backup software replace the drive Severity Warning 14024 Device or Software error Overrun Meaning A device or application error occurr
32. 0540 05 MMB Messages 28739 Adapter error Detach failed Meaning Detach failed Corrective action 1 Remove the device by using the fio detach command with the f option force removal 2 If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning mPCle SSD Windows related 29010 Adapter error Internal error 800GB card Meaning Internal error has occurred Corrective action Replace the PCle SSD card Severity Warning 29011 Adapter error Write performance reduced 800GB card Meaning Write performance is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 29012 Adapter error Write operations disabled 800GB card Meaning Write operations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 29013 Adapter error Write operations disabled 800GB card Meaning Write operations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 121 CA92344 0540 05 MMB Messages 290
33. 3 IOU_1GbE PCle SW 0 0 IOU 0 3 IOU_1GbE IOU 0 3 IOU_1GbE SB 0 IOU 0 3 IOU_1GbE PCle SW 0 1 IOU 0 3 IOU_1GbE IOU 0 3 IOU_1GbE SB 1 IOU 0 3 IOU_1GbE PCle SW 0 9 IOU 0 3 IOU_1GbE IOU 0 3 IOU 1GbE IOU 0 3 IOU 1GbE PCle SW 0 16 IOUZ 0 3 IOU_1GbE IOU 0 3 IOU 1GbE SB 2 IOU 0 3 IOU_1GbE PCle SW 0 17 IOU 0 3 IOU_1GbE IOU 0 3 IOU 1GbE SB 3 IOU 0 3 IOU_1GbE PCle SW 1 0 IOU 0 3 IOU_1GbE IOU 0 3 IOU_1GbE IOU4 0 3 IOU_1GbE PCle SW 1 1 lOU4 0 3 IOU 1GbE IOU 0 3 IOU_1GbE DU 0 1 RAID Card 0 1 1 IOUs 0 3 IOU 1GbE PCle SW 1 2 IOU 0 3 OU_1GbE IOU 0 3 IOU_1GbE IOU 0 3 IOU 1GbE PCle SW 1 8 IOU 0 3 OU_1GbE IOU 0 3 IOU_1GbE PCle 0 Card IOU 0 3 IOU 1GbE PCle SW 1 9 IOU 0 3 IOU 1GbE IOU 0 3 IOU 1GbE PCle 1 Card IOU 0 3 IOU 1GbE PCle SW 1 16 IOU 0 3 IOU 1GbE IOU 0 3 IOU 1GbE PCle 3 Card IOU 0 3 IOU_1GbE PCle SW 1 17 IOU 0 3 IOU_1GbE IOU 0 3 IOU_1GbE PCle 2 Card IOU 0 3 IOU_1GbE PCle 0 Card PCle 0 Card PCle 0 Card IOU 0 3 IOU 0 3 IOU_1GbE PCle 1 Card PCle 1 Card PCle 1 Card IOU 0 3 IOU 0 3 IOU_1GbE PCle 2 Card PCle 2 Card PCle 2 Card IOU 0 3 IOU 0 3 IOU_1GbE PCle 3 Card PCle 3 Card PCle 3 Card IOU 0 3 IOU 0 3 IOU_1GbE Onboard LAN IOU 0 3 IOU_1GbE IOU 0 3 IOU_1GbE IOU 0 3 IOU_10GbE PCle S
34. 3 PCI Box 0 3 PCle 05 Card PCle 05 Card PCle 05 Card PCI_Box 0 3 PCI Box 0 3 PCle 06 Card PCle 06 Card PCle 06 Card PCI Box4 0 3 PCI Box 0 3 PCle 07 Card PCle 07 Card PCle 07 Card PCI_Box 0 3 PCI Box 0 3 PCle 08 Card PCle 08 Card PCle 08 Card PCI Box 0 3 PCI Box 0 3 PCle 09 Card PCle 09 Card PCle 09 Card PCI Box4 0 3 PCI Box 0 3 PCle 10 Card PCle 10 Card PCle 10 Card PCI Box4 0 3 PCI Box 0 3 PCle 11 Card PCle 11 Card PCle 11 Card PCI Box4 0 3 complement corresponding first item and second item 1 corresponding IOUZ 0 3 and DUZ 0 1 and RAID Card 0 1 DU 0 RAID Card 0 IOU 0 DU 0 RAID Card 1 IOU 1 DU 1 RAID Card 0 IOU 2 DU 1 RAID Card 1 IOU 3 2 Corresponding of OU 0 3 and PCI Box 0 3 is not fixation it is necessary to confirm the connection on the IOU screen of MMB Web UI 3 Number does not adhere to PCI Box in 2Socket Lite Model 4socket Entry Model TABLE A 2 Replacement component list 2 Source Replacement component VDDQ DIMMOC Mezzanine 0 on SB xx VDDQ DIMMOD Mezzanine 0 on SB xx P1 0V_JC 0C Mezzanine 0 on SB xx P1 0V_JC 0D Mezzanine 0 on SB xx P1 5V_JC 0CD Mezzanine 0 on SB xx P1 35V_JCOCD Mezzanine 0 on SB xx VDDQ_DIMM1C Mezzanine 1 on SB xx VDDQ_DIMM1D Mezzanine 1 on SB xx P1 0V_JC 1C Mezzanine 1 on SB xx P1 0V_JC 1D Mezzanine 1 on SB xx P1 5V_JC 1CD Mezzanine 1 on SB xx P1 35V_JC1CD Mezzanine 1
35. 861 Added PCle lt x gt Meaning The addition of PCle lt x gt exited This indicates success of PCle hot add dr util INFO 870 Remove PCle lt x gt Meaning PCle lt x gt will be removed This indicates that OS will remove PCle lt x gt dr util INFO 871 Removed PCle lt x gt Meaning PCle lt x gt will be removed This indicates that OS will remove PCle lt x gt dr util INFO 880 Create report file at s Meaning The report file was created at s 207 CA92344 0540 05 sadump Messages 4 1 CHAPTER 4 sadump Messages This chapter describes the sadump messages which are displayed in the console sadump Message list Sadump messages are listed below ERROR An error occurred at reading EFI Variables xxx Meaning The configuration of sadump is broken Corrective action Set up sadump again ERROR All of the devices could not be opened Meaning All of the devices could not be opened Corrective action Set up sadump again ERROR All of the devices could not be used Meaning All of the devices could not be used Corrective action Set up sadump again Or reboot system and convert memory dump to a file to make dump device available ERROR I O error occurred at writing memory image Meaning I O error occurred at writing memory image Corrective action Set up sadump again ERROR An error occurred at reading the variables on the dump device Meaning An error occurred at reading
36. An OS panic has occurred Corrective action No action is necessary Severity Info 47 CA92344 0540 05 MMB Messages CO6FO8FF Power Off In Progress Meaning The partition power off is in progress Corrective action No action is necessary Severity Info CO6FO9FF Fatal Meaning A fatal hardware error has occurred Corrective action No action is necessary Severity Info CO6FOAFF Dumping Meaning A memory dump is being collected Corrective action No action is necessary Severity Info CO6FOBFF Halt Meaning Collection of the memory dump has been completed Corrective action No action is necessary Severity Info CO6FOCFF Stop Error Meaning An OS panic has occurred in the Windows OS Corrective action No action is necessary Severity Info CO6FODFF Extended Partitioning Firmware Running Meaning Extended Partitioning Firmware is operating Corrective action No action is necessary Severity Info 48 CA92344 0540 05 MMB Messages 2 1 14 MMB firmware related MMB firmware related messages are listed below C5A10300 MMB Firmware Update Failed Meaning MMB firmware updating has failed Corrective action MMB must be replaced Severity Error C5A10310 MMB 0 Firmware Update Failed Meaning Rebooting after updating the MMB 0 firmware update has failed and booting was done in the old version Corrective action MMB must be replaced Se
37. BC504110 PCI Receiver Buffer Overflow Bus Device 0x Function 0x Meaning An error was detected in the PCI express Link control system Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1_ Severity Error BC504120 PCI Malformed TLP Bus Device 0x Function 0x Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type B in the TABLE A 1 Replacement component list 1 Severity Error BC504130 PCI ECRC Error Bus Device 0x Function 0x Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC504140 PCI Unsupported Request Bus Device Ox Function Ox Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error 42 CA92344 0540 05 MMB Messages BC504150 PCI ACS Violation Bus Device 0x Function 0
38. Boot Device because OS loader is abnormal behavior Severity Error B0236F04 OS Watchdog Action Meaning Watchdog timer has timed out For the operation to be performed after the expiration of the Watchdog timer the operation specified by the ASR Automatic Server Restart Control would be prioritized if the number of retries specified by ASR Control has been exceeded If the retry frequency specified in the Control exceeded the operation specified in the ASR Control would be prioritized Corrective action Please check the operating status of the OS because this may be abnormal operation of OS Severity Error B0236F05 OEM Watchdog Meaning Watchdog timer has timed out For the operation to be performed after expiration of the Watchdog timer the operation specified by Automatic Server Restart ASR Control is prioritized if the retry count specified by ASR Control has been exceeded Corrective action Download the system event log and contact your sales representative or a field engineer Severity Error 35 CA92344 0540 05 MMB Messages gl2C related BMC B0C00157 l2C error ratio above warning level An error has occurred in BMC 12C bus Corrective action Replace the SB Severity Warning BOCO6F80 Il2C 12C Bus is blocked Meaning 12C bus error has occurred in the BMC Corrective action Replace the SB Severity Warning BOCO6F81 l2C I2C Bus OK Meaning BMC 1
39. Contact your sales representative or a field engineer Severity Error C8A104CA PCle SW Downstream Initialization Checksum Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10445 PCle SW Upstream Unmapped Register Initialization Attempt Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A104C5 PCle SW Downstream Unmapped Register Initialization Attempt Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10447 PCle SW Upstream PCle SW Status Check Failure Meaning A switch status check error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A104C7 PCle SW Downstream PCle SW Status Check Failure Meaning A switch status check error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error 57 CA92344 0540 05 MMB Messages C8A10448 PCle SW Upsiream Blank Serial EEPROM Meaning A swit
40. PCle lt x gt with error number lt y gt Corrective action The addition of PCle x failed because of the error y Please confirm the error messages and do corrective action according to error dr util ERR 461 Failed to remove Pcie lt x gt with error lt y gt Meaning Failed to remove PCle lt x gt with error number y Corrective action The remove of PCle lt x gt failed because of the error lt y gt Please confirm the error messages and do corrective action according to error Please try removing of PCle again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR d PCle lt x gt status is invalid lt y gt d 462 463 Meaning The status of PCle slot X is invalid Corrective action Failed to check the PCle lt x gt slot status Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR d Internal Error d 470 483 Meaning Internal error occurred Corrective action Please gather the information for investigation by using opt FJSVar util sbin dr report on the partition side and contact the technology of our company member Messages concerning trouble that occurs outside of DR command other
41. Replace the adapter Severity Warning 78 CA92344 0540 05 MMB Messages 11703 Adapter error NVM Read Error Meaning A hardware error was detected Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11710 Adapter error pattern test reg failed Meaning A hardware error was detected Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11711 Adapter error set check reg test failed Meaning The register test failed Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11712 Adapter error failed STATUS register test Meaning The register test failed Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11715 Adapter error Cannot do PHY loopback test when SoL IDER is active Meaning The PHY loopback test cannot be executed Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11731 Adapter error PF device is not up Meaning The PF device is not active Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11740 Adapter error PCle link lost device no detached Meaning Adapter is detached because of a link lost to an adapter Corrective action An adapter failure may have occurred Replace the adap
42. SYSTEM Status Sensor related SYSTEM Status Sensor related messages are listed below Remark PRIMEQUEST2400E2 2800E2 2400E 2800E only When some partitions are power off on at the same time multiple SYSTEM Status Sensor related messages may be logged CO6F0001 Unable to power on the partition because CPU or Memory cannot be allocated Meaning The partition remains power off state because CPU or Memory resource cannot be allocated Corrective action Check the resources of the partition by MMB Web UI Severity Info CO6FOOFF Power Off Meaning The power is Off Corrective action No action is necessary Severity Info 46 CA92344 0540 05 MMB Messages CO6F01FF Power On In Progress Meaning The power on process is in progress Corrective action No action is necessary Severity Info CO6FO02FF Reset Meaning Resetting is in progress Corrective action No action is necessary Severity Info CO6FO3FF EFI Meaning The EFI is in operation Corrective action No action is necessary Severity Info CO6FO4FF Boot Meaning The OS is booting Corrective action No action is necessary Severity Info CO6FO5FF OS Running Meaning The OS is in operation Corrective action No action is necessary Severity Info CO6FO6FF OS Shutdown Meaning The OS is shutting down Corrective action No action is necessary Severity Info CO6FO7FF Panic Meaning
43. Update on bb because cc is set as Home powered on Meaning The firmware cannot be updated for the aa firmware update target bb because cc is Home and is in the power on status Corrective action Turn off the power Severity Info 00229 Unable to execute aa Firmware Update on bb during Hot Partition Maintenance Meaning The firmware cannot be updated for the aa firmware update target bb because it is in the status of Hot partition maintenance Corrective action Cancel the Hot partition maintenance Severity Info 00230 Unable to execute MMB Firmware Update during aa Meaning MMB firmware cannot be updated because it is aa Corrective action Set the appropriate maintenance mode or execute the update if it is not under maintenance Severity Info 00231 Unable to execute MMB Firmware Update because a partition is powered on Meaning The MMB firmware cannot be updated because the partition power is on Corrective action Turn of the partition power Severity Info 169 CA92344 0540 05 MMB Messages 00232 The system will leave Maintenance Mode Are you sure Meaning When an attempt was made to cancel the maintenance mode and the OK button is clicked Canceling the maintenance mode Another user may be performing maintenance Are you sure is notified Corrective action When the OK button is clicked when canceling the maintenance mode the first window would be d
44. Upper Non critical going high Assert V threshold V Meaning High voltage warning has occurred Corrective action Target board must be replaced When Unit in SEL is SB xx identify the replacement parts by referring to TABLE A 2 Replacement component list 2 Severity Warning 020109FF Upper Critical going high Assert V threshold V Meaning High voltage error has occurred Corrective action Target board must be replaced When Unit in SEL is SB xx identify the replacement parts by referring to TABLE A 2 Replacement component list 2 Severity Error 028100FF Lower Non critical going low Deassert V threshold V Meaning Low voltage warning was canceled Corrective action No action is necessary Severity Info 028102FF Lower Critical going low Deassert V threshold V Meaning Low voltage error was canceled Corrective action No action is necessary Severity Info 028104FF Lower Non recoverable going low Deassert V threshold V Meaning Low voltage error was canceled Corrective action No action is necessary Severity Info 028107FF Upper Non critical going high Deassert V threshold V Meaning High voltage warning was canceled Corrective action No action is necessary Severity Info 028109FF Upper Critical going high Deassert V threshold V Meaning High voltage error was canceled Correctiv
45. address or you change a subnet please change MMB IP address first Meaning A subnet of Console Redirection differs from MMB IP address Corrective action Please change to a different IP address If you change a MMB IP subnet please change MMB IP address first Severity Warning W_00602 Unable to set Extended Partitioning Mode because Power Save Control is enabled Meaning Extended Partition Mode is unable to set because Partition Power Save Control is enabled Corrective action Check the Partition Power Save Control settings Severity Warning W_00603 Unable to set Partition Power Save Control because Extended Partitioning Mode is enabled Meaning Partition Power Save Control is unable to set because Extended Partitioning Mode is enabled Corrective action Check the Extended Partitioning Mode settings Severity Warning 00604 Setting completed CAUTION Assignment of VGA USB2 rKVMS cannot be changed if the Extended Partition is powered on Please release VGA USB2 rKVMS after the operation Note IP Address Video Redirection and Virtual Media for all Extended Partitions must be enabled in Partition gt Console Redirection Setup menu Meaning Assignment of VGA USB2 rKVMS cannot be changed if the Extended Partition is powered on Please release VGA USB2 rKVMS after the operation Corrective action Free the assignment of VGA USB2 rKVMS Severity Info 194 CA92344 0
46. again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVadr util sbin dr report on the partition side and contact the technology of our company member dr util WARNING 428 Some CPUs and or MEMs are busy will retry Remove Meaning It takes time to the disabling process of CPU and memory during SB hot remove It may be displayed during SB hot remove Corrective action No action is necessary dr util ERR 440 Failed to add IOU x with error lt y gt Meaning Failed to add IOU x with error number y Corrective action The addition of IOU x failed because of the error y Please try adding of IOU again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 441 Exited x with status y at lt z gt timing Meaning Collaboration program lt x gt exited with status y at lt z gt timing lt z gt represents before or after Corrective action IOU hot add was aborted because of the failure of collaboration program lt x gt Please review the output messages of collaboration program lt x gt dr util ERR 450 Failed to remove IOU x with error lt y gt Meaning Failed to remove IOU x with error number lt y gt Corrective action The
47. because the partition is in the Power Off state Corrective action Change the mode after turning on the partition power Severity Warning W_00516 The replaced SB is unsupported Please check then reinstall the SB d Meaning An unsupported SB was replaced Corrective action Replace after checking the SB Severity Warning E 00517 Unable to power on the partition d due to abnormal SB composition Meaning The partition cannot be powered on because of a problem in the SB configuration Corrective action Check the mix status of the SB configuring the partition Severity Error W 00518 Unable to power on the partition d due to SB composition abnormal After checking SB status and configuration please come back to the Replacement Instruction Window and reinstall the unit Meaning If there is a problem in the configuration of the SB in the Power On process of the partition Unable to power on the partition due to a problem in the SB configuration is notified Corrective action The next window is be displayed by clicking the OK button of the dialog Check if there is any problem in the SB of the currently displayed window Return up to the replacement instruction window and perform the replacement again Severity Warning E 00519 Unable to add the specified SB to the partition due to SB composition abnormal Meaning The specified SB cannot be added to the partition because of problem in its confi
48. because the partition is running Corrective action Shut down the partition and try changing the Home SB again Severity Warning 131 CA92344 0540 05 MMB Messages The setting will become effective the next time the partition power off on is performed Meaning The setting of the powered on partition has been changed To reflect the setting value turn On Off the partition power Corrective action No action is necessary Severity Info Unable to execute this command because you have not authority to operate this partition Meaning The Partition Operator has executed the CLI command for a partition which is not a management target The process cannot be executed This error message is displayed only for partition Operators Corrective action Check the command parameter and the processing target partition Severity Warning Unable to change the mode because Memory Operation Mode is not spare mode Meaning The mode cannot be changed because Memory Operation Mode of the partition is not sparing mode Corrective action Check the command parameter and the processing target partition Severity Warning Failed to execute s command Meaning The CLI command has terminated abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error Failed to execute set partition command Mean
49. buffer An I O request sent to the SCSI device was rejected Corrective action Identify the type of the target device from its host id and lun Then check the sense key extended sense to determine the corrective action 1 Recovered Error If it is a removable device perform cleaning 2 Not Ready If it is non removable replace the device 3 Medium Error If it is a disk replace the device If it has removable media perform cleaning and replace the media 4 Hard Error Replace the device 5 Illegal Request Examine the software 6 Unit Attention This is notification information from various devices e g reset status RAID degradation if applicable 7 Data Protect Check the Write Protect status 8 Blank Check Check tape and other operations 9 Aborted Command Investigate problems in the SCSI bus and FC transmission paths Severity Warning 14139 Device error I O error Meaning An I O error occurred Corrective action If the return code is 0x00010000 a no response error occurred on the disk Replace the disk If another return code is returned identify the type of the target device from its host id and lun Then check the sense key extended sense to determine the corrective action 1 Recovered Error If it is a removable device perform cleaning 2 Not Reagy If it is non removable replace the device 3 Medium Error If it is a disk replace the device If it has removable media perform
50. cleaning and replace the media 4 Hard Error Replace the device 5 Illegal Request Examine the software 6 Unit Attention This is notification information from various devices e g reset status RAID degradation if applicable 7 Data Protect Check the Write Protect status 8 Blank Check Check tape and other operations 9 Aborted Command Investigate problems in the SCSI bus and FC transmission paths Severity Warning 14165 Device error Meaning A No Sense error occurred in the device The return value from the HBA is displayed as is Corrective action Check the sense key included in the message Take corrective action as described below according to the character string of the sense key For No Sense Recovered Error or Unit Attention gt gt If the error occurred alone no action is necessary If the error has occurred repeatedly collect the data for investigation dump or fjsnap and contact your sales representative or a field engineer For Medium Error Replace the disk or tape For Blank Check Check the read and write operations of the disk or tape If there is no problem in operations collect the data for investigation dump or fjsnap and contact your sales representative or a field engineer Other Collect the data for investigation dump or fjsnap Contact your sales representative or a field engineer Severity Warning 104 CA92344 0540 05 MMB Message
51. could not be determined by the MMB Corrective action Collect a detailed log and determine the failure location following the analysis procedure for determining failure locations provided by your sales representative or a field engineer If the failure location cannot be determined contact your sales representative or a field engineer Severity Error 58 CA92344 0540 05 MMB Messages C8A20F00 Undetermined hardware fatal error Meaning The failure location could not be determined by the MMB Corrective action Collect a detailed log and determine the failure location according to the analysis procedure for determining faulty locations provided by your sales representative or a field engineer If the location of failure cannot be determined contact your sales representative or a field engineer Severity Error C8A90404 PCI Express Lane degraded Meaning Lane degradation was detected in the PCle Port of the PCle Switch Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Warning C8A90405 PCI Express Speed degraded Meaning Speed degradation was detected in the PCle Switch PCle Port Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Warning C8A90504 PCI Express Lane degraded VendorlID 04x DevicelD 04x SubvendorlID 04x Subsystem 04x on I
52. field engineer Severity Error C8A1049A PCle SW Downstream Unsupported Request Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A1049B PCle SW Downstream ACS Violation Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A1049C PCle SW Downstream Uncorrectable Internal Error Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error 55 CA92344 0540 05 MMB Messages C8A10440 PCle SW Upsiream Access Failure Meaning A switch i2C access error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A104CO PCle SW Downstream Access Failure Meaning A switch i2C access error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10441 PCle SW Upstream No Acknowledge Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales r
53. in the Standby MMB or it is Disabled Corrective action Check the status of the Standby MMB Severity Warning W 00479 Unable to execute the update TPM is effective Meaning The firmware update cannot be executed because the TPM function is enabled for a partition Corrective action Check the TPM setting of the partition Severity Warning 185 CA92344 0540 05 MMB Messages W 00481 Unable to register the specified SB s as a Reserved SB due to the home SB is TPM enabled Meaning The specified SB cannot be specified as a Reserved SB because the TPM function of the Home SB is enabled Corrective action Check the Home SB setting Severity Warning W 00487 Unable to change the mode because this partition is powered on Meaning The mode cannot be changed because the partition power is on Corrective action Turn off the partition power and then change the mode Severity Warning E 00490 Unable to add the specified SB to the partition due to DIMM does not satisfy requirements of Mode Meaning The specified SB cannot be added to the partition because the Memory Mode cannot support the DIMM Corrective action Check the location and mix status of the DIMMs mounted on the SB Severity Error E 00491 Unable to power on the partition d due to DIMM does not satisfy requirements of Mode Meaning Unable to power on the partition d because the DIMM is in a configuration that does not meet the
54. model type Please select a valid firmware file model type Meaning The file specified for the firmware update process is not a firmware file Corrective action This window is displayed again when the OK button is clicked Specify the correct firmware file Severity Warning 171 CA92344 0540 05 MMB Messages W 00241 Specified firmware file aa is invalid Please select a valid firmware file Meaning The file specified for the firmware update process contains a header error checksum error Corrective action This window is displayed again when the OK button is clicked Specify the correct firmware file Severity Warning W 00242 Specified file size is invalid Please select a valid firmware file Meaning The file specified for the firmware update process is an abnormal firmware file abnormal size Corrective action This window is displayed again when the OK button is clicked Specify the correct firmware file Severity Warning W 00243 Failed to clear the status of aa but maintenance will still continue After Maintenance completion Check the System Event Log Window to refer to the error details Meaning The user has clicked the Status Clear button is clicked but status clear for aa has failed Corrective action Click the OK button in the dialog box to proceed to the next window Severity Warning W 00246 The aa firmware update has been failed Please retry to update the firmware
55. necessary Severity Info Failed to execute set partition name command Meaning The set partition name command has terminated abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error Succeed to set partition home command Meaning The set partition home command has terminated normally Corrective action No action is necessary Severity Info Failed to execute set partition home command Meaning The set partition home command has terminated abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error 133 CA92344 0540 05 MMB Messages Failed to execute show partition configuration command Meaning The show partition configuration command has terminated abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error Home SB is not set in Partition x Meaning The Home SB is not defined in Partition x Corrective action Confirm that the partition is correctly specified Also confirm the partition configuration Severity Warning Failed to execute show partition home command Meaning The show partition home command has terminated
56. not canceled it is necessary to exchange the FBU Severity Warning C8A70E04 BBU on RAID controller removed Meaning The voltage has decreased remarkably Corrective action Please confirm firmware version of the RAID controller and update latest version Please wait for the charge completion of the battery Please exchange FBU when the problem is not canceled after the charge is completed Severity Warning C8A70E05 BBU on RAID coniroller BBU charger problem detected SOH bad Meaning The charge with the battery is insufficient Corrective action Please exchange FBU Severity Warning C8A70E06 BBU on RAID controller Error with the remote BBU connector cable detected Meaning Problem of the cable of FBU was detected Corrective action Please exchange the cable of FBU Severity Warning 62 CA92344 0540 05 MMB Messages C8A70E07 BBU on RAID controller requires reconditioning please initiate recalibration Meaning The reconditioning of the battery is necessary Corrective action 1 Please do the recalibration Please do not interrupt the charge by reboot and shutdown 2 When the problem is not canceled it is necessary to exchange the FBU 3 When the problem is not canceled please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C8A70E08 BBU on RAID controller retention test failed Meaning I
57. occurred Corrective action The error occurred while gathering information Please execute the command again after removing the error factor Messages concerning trouble that occurs in DR command dr util ERR 201 Another DR command is running pid d Meaning Another DR command is running Its process ID is d Corrective action DR command cannot run concurrently Please execute it again after already running DR command Process ID is d ends In case there s no process whose Process ID is 96d or in case the process whose Process ID is d is not the process of DR command please delete the var log dr pid file dr util ERR d Cannot confirm DR command status d 202 204 Meaning The state of the DR command cannot be confirmed The DR command was aborted because the state of the DR command was not able to be confirmed Corrective action Please execute the command again When the improvement is not seen even if it is executed again please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 205 Must be root for dr operations Meaning Only the user with root permission can do DR operation Corrective action The user without root permission tried to execute the DR command Please execute it again by the user with root permission dr util ERR d This operation is prohibited d 206 209 Meaning
58. output at the same time and replace the unit Severity Error 20 CA92344 0540 05 MMB Messages 2 1 7 2B6F0401 Configuration error Board type Meaning Memory Scale up Board is mounted Corrective action Replace the Memory Scale up Board by SB Severity Error 2B6F0402 Configuration Number of units Meaning The Number of mounted SB or Memory Scale up Board exceeds limitation Corrective action Check configuration and remove SB or Memory Scale up Board from Chassis Severity Error Mezzanine related The Mezzanine related messages are listed below 280700FF Transition to OK Meaning The status is normal Corrective action No action is necessary Severity Info 280701FF Transition to Non critical from OK Meaning The status has changed from normal to warning Corrective action The target unit must be replaced Refer the message that is output at the same time and replace the unit Severity Warning 280702FF Transition to Critical from less severe Meaning The status has become abnormal Corrective action The target unit must be replaced Refer the message that was output at the same time and replace the unit Severity Error 280703FF Transition to Non recoverable from less severe Meaning There has been a transition to an abnormal state Corrective action The target unit must be replaced Refer the message that was output at the same time and replace the unit
59. refer to the error details Meaning The Log saving operation cannot be continued because the log saving could not continue Corrective action Save the log again If the same event occurs click the Next button complete the maintenance work and check the system event log Severity Warning 00225 Unable to execute aa Firmware Update on bb because cc is not under maintenance Meaning The firmware cannot be updated for the aa firmware update target bb because cc is under maintenance Corrective action Set the maintenance mode Severity Info 168 CA92344 0540 05 MMB Messages W_00225 The unit is not present Please come back to the Replacement Instruction Window and install the unit Meaning The maintenance target unit is not installed Corrective action Return to the replacement instruction window and install the target unit Severity Warning 00226 Unable to execute aa Firmware Update on bb because cc is not free Meaning The firmware could not be updated for the aa firmware update target bb because cc is not free Corrective action Change the unit status to Free Severity Info 00227 Unable to execute aa Firmware Update on bb because cc is reserved Meaning The firmware cannot be updated for the aa firmware update target bb because cc is reserved Corrective action Cancel the Reserved SB status Severity Info 00228 Unable to execute aa Firmware
60. remove of IOU x failed because of the error y Please try removing of IOU again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVar util sbin dr report on the partition side and contact the technology of our company member dr util ERR 451 Exited x with status y at lt z gt timing Meaning Collaboration program lt x gt exited with status y at lt z gt timing lt z gt represents before or after Corrective action IOU hot remove was aborted because of the failure of collaboration program lt x gt Please review the output messages of collaboration program lt x gt 203 CA92344 0540 05 Dynamic Reconfiguration Messages 3 4 dr util ERR d lOU lt x gt status is invalid lt y gt d 453 454 Meaning The status of IOU slot X is invalid Corrective action Failed to check the IOU x slot status Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR d Internal Error d 455 456 Meaning Internal error occurred Corrective action Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 460 Failed to add Pcie lt x gt with error lt y gt Meaning Failed to add
61. reset retry exhausted stop reset operation Meaning The adapter reset count exceeded the upper limit Stop the reset process Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13191 Adapter error adapter reset failed Meaning The adapter reset failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13192 Adapter error IOC msg unit reset failed to put ioc in ready state Meaning The reset of the IOC message unit for placing the IOC in the standby state failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 97 CA92344 0540 05 MMB Messages 13193 Adapter error Errata on LSI53C1030 occurred Meaning Errata No 28 of LSI53C1030 chip occurred during reading of the data Corrective action Re execute read after converting the target block size of the target data into multiples of eight If the error keeps recurring collect the data for investigation dump or fjsnap and contact your sales representative or a field engineer Severity Warning 13194 Device error target reset failed Meaning The target reset failed Corrective action Replace the target device If the error keeps recurring contact
62. restore it Still when the problem continues it is necessary to exchange the HDD Severity Warning E77E03XX Logical drive n failed PCIBox n Slot n Port n Cascade Meaning The logical drive n broke down Corrective action It is likely to be able to recover without losing data Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning 68 CA92344 0540 05 MMB Messages E77E0400 Logical drive n bad block table is full PCIBox or IOUZn Slotzn Meaning Bad block table of logical drive is full Corrective action Please confirm added error message of the disk drive Severity Warning C9A10F0X Fan n will fail in near future PCIBox n Slot n Port n Cascade s Meaning The FAN will break down in the near future X is the FAN number s is disk enclosure model name Corrective action The FAN is mounted in the PSU and exchange PSU ahead of time though the exchange of FAN is necessary Attention Please do not operate the system with the cover removed In that case the operation of FAN is not guaranteed Severity Warning C9A10F1X Fan n failed PCIBox n Slot n Port n Cascade s Meaning The FAN broke down X is the broke down FAN number s is disk enclosure model name Corrective action The FAN is mounted in the PSU and exchange the PSU ahead of time though the exchange of FAN is necessary A
63. settings after shutting down the partition Corrective action Perform the setting after shutting down the partition Severity Warning E 00424 Unable to add the specified SB to the partition due to CPU composition abnormal Meaning The specified SB cannot be added to the partition since there is an error in the partition configuration Corrective action Please set the number of CPUs mounted on the SB to at least two Severity Error E 00425 Unable to add the specified SB to the partition due to DIMM composition abnormal Meaning The specified SB cannot be added to the partition since there is an error in the DIMM configuration Corrective action Place the SB mounted DIMM in such a way that it meets the Mirror Mode requirements Severity Error W_00426 Invalid values specified Meaning An invalid value has been specified Corrective action Check the input data Severity Warning 00427 Select a partition Meaning The partition has not been selected Corrective action Select a partition and then click the button Severity Info 178 CA92344 0540 05 MMB Messages 00428 The partition is not defined Meaning That partition has not been defined Corrective action Select only a defined partition Severity Info W_00429 Only the alphanumeric character can be input to Partition Name area Meaning Only alphanumeric characters can be entered for the partition name Correctiv
64. sure to continue Meaning An SB containing a DIMM that does not meet the requirements of the Mirror Mode is allocated as a Reserved SB When the partition specified thus is registered as a Mirror Mode the Mirror Mode will be canceled when switching to the Reserved SB The message asks for confirmation to continue processing Corrective action To continue the setting click the OK button in the confirmation dialog box To cancel the setting click the Cancel button in the confirmation dialog box Severity Info 00502 The firmware is updating Meaning Notifies that it is a firmware update is in progress Corrective action None Severity Info W 00504 The Power On failed because of switching the Home SB Execute it after a while again Meaning Power on has failed since the Home SB is being switched Retry after some time Corrective action Retry after some time Severity Warning W 00505 Unable to set configuration because the power on off is processing Execute it after a while again Meaning The partition configuration cannot be changed because the power of the partition is in operation Wait for some time and then retry Corrective action Wait for some time and then retry Severity Warning 188 CA92344 0540 05 MMB Messages W_00506 Unable to set the OS Installation Mode because this partition is powered off Meaning The installation mode of the operating system cannot be set
65. the MMB Severity Warning Are you sure to continue set active mmb y n Meaning Confirm the message that prompts for setting the Active MMB Corrective action No action is necessary Severity Info Same name already exists User addition failed Meaning User addition failed because same name already exists Corrective action Check user in LDAP User Group List Severity Error set active_mmb failed Meaning The set active_mmb command process has failed This message is displayed when there is an Offline processing error Active MMB reset failure other processing exception has occurred Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error The specified date is invalid Meaning The format of the specified date is invalid Corrective action Check the command parameter Severity Warning Unable to set date because NTP is enabled Meaning The set date command cannot be executed since the NTP is enabled Corrective action Disable the NTP when executing the set date command Severity Warning Time synchronization was requested to Standby MMB Meaning The date time zone synchronization is specified on the standby MMB Corrective action None Severity Info The specified time zone is invalid Meaning The specified time zone is invalid Corrective action Check the command parameter Severity Warning
66. the because of the mismatch of the CPUs installed between the SBs Corrective action Check the location and the status of mix of the CPUs mounted on the SBs Severity Error E 00498 Unable to register the specified Partition s as Mirror Mode enable because the unsupported CPU configuration Meaning The Mirror Mode cannot be set for partition d because the CPU does not meet the mounting conditions Corrective action Check the location and status of mix of the CPU of SB configuring the partition Severity Error 187 CA92344 0540 05 MMB Messages E 00499 Unable to register the specified Partition s as Mirror Mode enable because of abnormal CPU composition Meaning The Mirror Mode cannot be set for partition d because of a problem in the CPU configuration Corrective action Check the configuration of the CPU of the SB configuring the partition Severity Error E 00500 Unable to register the specified Partition s as Mirror Mode enable because of abnormal DIMM composition Meaning The Mirror Mode cannot be set for partition d because of a problem in the DIMM configuration Corrective action Check the of the DIMM configuration of the SB configuring the partition Severity Error 00501 The SB with DIMM that does not satisfy requirements of Mirror Mode is registered as a Reserved SB If you register this partition as a Mirror Mode Mirror Mode will be disabled when switching to Reserved SB Are you
67. the corresponding HDD in order to prevent system slow down However MMB firmware does not disconnect when it can cause data corruption Severity Warning E76F03FF Physical disk failed model Meaning The HDD error was detected Corrective action Replace the HDD Severity Warning 63 CA92344 0540 05 MMB Messages E76FO5FF Physical disk rebuilding model Meaning The HDD rebuilding is in progress Corrective action No action is necessary Severity Info E76FO6FF Physical disk Global Hot Spare created model Meaning The HDD global hot spare was created Corrective action No action is necessary Severity Info E76F07FF Physical disk bad block table is full model m Meaning The bad block table of HDD is full Corrective action Replace the HDD Severity Warning E76F08FF Physical disk shielded model m Meaning The HDD is shielded state Corrective action Replace the HDD Severity Warning E7EFO6FF Physical disk Global Hot Spare deleted model Meaning The HDD global hot spare was deleted Corrective action No action is necessary Severity Info E77E01FF Logical drive partially degraded Meaning The redundancy is kept though the logical drive did degradation Corrective action Replace the HDD Severity Warning E77E02FF Logical drive degraded Meaning The logical drive did degradation and the redundancy was lost Corrective action Re
68. the status of the CPU which is mounted on the SB One CPU can be mounted per SB only if one partition is configured per SB Two CPUs must be mounted per SB if one partition is configured in several SBs Severity Error Unable to register the specified SBZx as a Reserved SB because the DIMM does not satisfy requirements of Mirror Mode Meaning The specified SB cannot be registered as a Reserved SB since the DIMM does not meet the requirements of the Mirror Mode Corrective action Check the status of the DIMM which is mounted on the SB Severity Error 138 CA92344 0540 05 MMB Messages Unable to register the specified SB x as a Reserved SB due to CPU composition abnormal Meaning The SB cannot be specified as a Reserved SB since the CPU configuration is abnormal Corrective action Check the status of the CPU which is mounted on the SB Severity Error Unable to register the specified SB x as a Reserved SB due to the home SB is TPM enabled Meaning The SB cannot be specified as a Reserved SB since the TPM function of the Home SB is enabled Corrective action Check the setting details of the Home SB Severity Error Unable to register the specified SB x as a Reserved SB due to CPU mismatch between SBs Meaning The SB cannot be specified as a Reserved SB since there is mismatch of CPs mounted between the SBs Corrective action Make sure that the CPU mounted on the SB which is partitioned and the CPU mou
69. ts fujitsu com Abbreviations This manual uses the following product name abbreviations Formal product name Abbreviation Microsoft Windows Server 2012 R2 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 Standard Windows Windows Server 2012 Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise Microsoft Windows Server 2008 R2 Datacenter Windows Windows Server 2008 R2 Red Hat Enterprise Linux 7 for Intel64 Linux RHEL7 RHEL Red Hat Enterprise Linux 6 for Intel64 Linux RHEL6 RHEL Oracle Linux 6 x86_64 Oracle Linux Oracle Linux 6 VMware vSphere R 6 VMware vSphere 6 x VMware 6 VMware 6 x VMware R ESXi TM 6 ESXi ESXi 6 ESXi x VMware vSphere R 5 VMware vSphere 5 x VMware 5 VMware 5 x VMware R ESXi TM 5 ESXi ESXi 5 ESXi 5 x Novell R SUSE R LINUX Enterprise Server 12 SLES12 Novell R SUSE R LINUX Enterprise Server 11 Service Pack 3 SLES11 SP3 Trademarks Microsoft Windows Windows Server Hyper V and BitLocker are trademarks or registered trademarks of Microsoft Corporation in the United States and or other countries Linux is a registered trademark of Linus Torvalds Red Hat the Shadowman logo and JBoss are registered trademarks of Red Ha
70. y gt kB failed Please try removing of SB again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVadr util sbin dr report on the partition side and contact the technology of our company member 202 CA92344 0540 05 Dynamic Reconfiguration Messages dr util ERR 424 Failed to eject SB lt x gt with error lt y gt Meaning Failed to remove SB lt x gt with error number y Corrective action The remove of SB lt x gt failed because of the error lt y gt Please try removing of SB again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVadr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 425 Exited lt x gt with status lt y gt at lt z gt timing Meaning Collaboration program lt x gt exited with status y at lt z gt timing lt z gt represents before or after Corrective action SB hot remove was aborted because of the failure of collaboration program lt x gt Please review the output messages of collaboration program lt x gt dr util ERR 426 Failed to remove SB lt x gt Meaning The remove of SB lt x gt terminated abnormally Corrective action The remove of SB lt x gt aborted Please confirm the error messages and do corrective action according to error Please try removing of SB
71. your sales representative or a field engineer Severity Warning 13184 Adapter error firmware upload failure Meaning The adapter firmware upload failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 96 CA92344 0540 05 MMB Messages 13185 Adapter error firmware downloadboot failure Meaning The firmware downloadboot operation failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13186 Adapter error host page buffers free failed Meaning Releasing the host page buffer failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13187 Adapter error Firmware Reload FAILED Meaning The pointer value of the request frame is null or outside its range Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13188 Adapter error pci enable device memY failed Meaning pci enable device mem PCI device initialization failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13190 Adapter error adapter
72. 0 3 PCle SW 0 1 PCI Box 0 3 PCI Box 0 3 PCle 02 Card PCI Box 0 3 PCle SW 0 4 PCI Box 0 3 PCI Box 0 3 PCle 04 Card PCI Box 0 3 PCle SW 0 5 PCI Box 0 3 PCI Box 0 3 PCle 03 Card PCI Box 0 3 PCle SW 0 8 PCI Box 0 3 PCI Box 0 3 PCle 01 Card PCI Box 0 3 PCle SW 0 9 PCI Box 0 3 PCI Box 0 3 PCle 00 Card CA92344 0540 05 Appendix A Replacement component list Unit Source Replacement component Replacement component TypeB TypeA First item Second item PCI Boxtt 0 3 PCle SW 0 12 PCI Box 0 3 PCI Box 0 3 PCle 05 Card PCI_Box 0 3 PCle SW 1 0 PCI_Box 0 3 PCI_Box 0 3 IOU 0 3 2 PCI Box 0 3 PCle SW 1 1 PCI Box 0 3 PCI Box 0 3 PCle 08 Card PCI Box 0 3 PCle SW 1 4 PCI Box 0 3 PCI Box 0 3 PCle 10 Card PCI Box 0 3 PCle SW 1 5 PCI Box 0 3 PCI Box 0 3 PCle 09 Card PCI Box 0 3 PCle SW 1 8 PCI Box 0 3 PCI Box 0 3 PCle 07 Card PCI Box 0 3 PCle SW 1 9 PCI Box 0 3 PCI Box 0 3 PCle 06 Card PCI Boxtt 0 3 PCle SW 1 12 PCl_Box 0 3 PCI Box 0 3 PCle 11 Card PCI Box 0 3 PCle 00 Card PCle 00 Card PCle 00 Card PCI Box4 0 3 PCI Box 0 3 PCle 01 Card PCle 01 Card PCle 01 Card PCI Boxd 0 3 PCI Box 0 3 PCle 02 Card PCle 02 Card PCle 02 Card PCI_Box 0 3 PCI Box 0 3 PCle 03 Card PCle 03 Card PCle 03 Card PCI Box 0 3 PCI Box 0 3 PCle 04 Card PCle 04 Card PCle 04 Card PCI Box4 0
73. 14 Adapter error Memory is close to wearing out 800GB card Meaning The product lifetime end for write operation will come soon If the device is still used it will be switched to the Read Only mode and then the data will NOT be written to the device anymore Corrective action Replace the PCle SSD card to the new one which is already purchased Severity Info 29015 Adapter error Reliability degraded 800GB card Meaning The reliability is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 29016 Adapter error Temperature above warning threshold 800GB card Meaning Temperature exceeded the upper warning threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 29017 Adapter error Adapter removed 800GB card Meaning Adapter is removed Corrective action Replace the PCle SSD card Severity Warning 29060 Adapter error Internal error 1 6TB card Meaning Internal error has occurred Corrective action Replace the PCle SSD card Severity Warning 29061 Adapter error Write performance reduced 1 6TB card Meaning Write performance is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Con
74. 2344 0540 05 MMB Messages 28732 Adapter error Write regulation activated to ensure adapter lifespan Meaning Writing is restricted to preserve the adapter service life Corrective action Reduce the write load Severity Warning 28733 Adapter error Running in minimal status Meaning The device is running in the minimal state Corrective action Collect investigation materials e g fisnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28734 Adapter error PCI power budget alarm Meaning A PCI power failure occurred Corrective action Collect investigation materials e g fisnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28735 Adapter error LEB map missing Meaning The LEB map was lost Corrective action Collect investigation materials e g fisnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28737 Adapter error Reserves depleted Meaning Reserved areas have been depleted Corrective action Check the format size Release reserved space by formatting with a smaller size Severity Warning 28738 Adapter error Attach failed Meaning Attach failed Corrective action Collect investigation materials e g fisnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 120 CA92344
75. 2C bus was restored Corrective action No action is necessary Severity Info B0C08157 l2C error ratio OK Meaning BMC 12C bus was restored Corrective action No action is necessary Severity Info B0C08159 l2C error ratio above warning level Meaning 12C bus error occurred in BMC Corrective action Replace the SB Severity Warning Diagnostic related BMC BOCB60 NICZ diagnostic error Meaning An error occurred in BMC NIC Corrective action Replace the SB Severity Error 36 CA92344 0540 05 MMB Messages BOCB61 12C diagnostic error Meaning An error occurred in BMC 12C bus Corrective action Replace the SB Severity Error BOCB62 l2C GPIO diagnostic error Meaning An error has occurred in BMC GPIO Corrective action Replace the SB Severity Error BOCB6300 l2C EEPROM diagnostic error Meaning An error has occurred in BMC EEPROM Corrective action Replace the SB Severity Error BOCB64 VSP diagnostic error Meaning An error has occurred in BMC VSP Corrective action Replace the SB Severity Error BOCB6500 PECI diagnostic error Meaning An error has occurred in BMC PECI bus Corrective action Replace the SB Severity Error BOCB66 SPI diagnostic error Meaning An error has occurred in the SPI bus Corrective action Replace the SB Severity Error BOCB6700 Firmware stack
76. 388 Diag NAND FMEM Fsck Error Meaning The content of the file system is incorrect The error of the file system cannot be corrected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070390 Diag Special Purpose Register Error Meaning Register write error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070392 Diag SDRAM Correctable Error Logging Limit Reached Meaning Correctable error occurred frequently and has reached the replacement threshold Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070395 Diag System EEPROM Read Error Meaning An EEPROM read error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070397 Diag CPLD Reset Register Error Meaning A CPLD read error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070398 Diag NAND FMEM Not Found Meaning NANDFMEM could not be found Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 1507039C Diag IIC PCA9551 Write Error Meaning An 12C write error has occurred during the
77. 4 0540 05 Overview of Messages CHAPTER 1 Overview of Messages This chapter describes how to read the PRIMEQUEST 2000 series messages 1 1 How to read the MMB messages This chapter describes how to read the messages that are stored in the MMB For the details on how to open the MMB window see 1 7 Basic operations of the Web UI window in the PRIMEQUEST 2000 series User Interface Operating Instructions CA92344 0538 For the MMB messages see Chapter 2 MMB Messages Note If a Part Number or Serial Number UI contents or information area displays Read Error check the details of the error in 11 2 Troubleshooting in the PRIMEQUEST 2000 series Administration Manual CA92344 0537 If the problem could not be resolved even then contact your sales representative or field engineer Before contacting confirm the model name and serial number shown on the label affixed to the main unit If Read Error is displayed do not perform operations in the partitions Reset or Force Power Off FIGURE 1 1 Information area Model PRIMEQUEST Active MMB amp 0 Part Number ABC12345 Serial Number ABCO0123456789 Under Maintenance Status Normal Partition 0 2 3 Partition User Administration Network Configuration Maintenance gt System gt System Status 1 1 1 System event log The events that occur in the PRIMEQUEST2000 series are stored as a system event log The MMB Web UI System Event Log window displays the
78. 446 CSR is exported Are you sure Meaning Retrieves the CSR The message asks whether to continue the process Corrective action Not required Severity Info W 00447 Private Key doesn t exist Meaning The secret key is not registered Displayed when an attempt is made to Export without registering the Key Corrective action Register the secret key Severity Warning W 00448 CSR doesn t exist Meaning CSR not registered Displayed when an attempt is made to Export without registering the CSR Corrective action Register the CSR Severity Warning W 00449 A certificate file is not selected yet Meaning The certificate file has not been selected Corrective action Specify a certificate file and import Severity Warning 00450 aa is imported Are you sure Meaning aa will be imported The message asks whether to continue the process Corrective action Not required Severity Info 181 CA92344 0540 05 MMB Messages W_00452 Self signed Certificate is not able to create because HTTPS is enabled A self signed certificate cannot be created since HTTPS has been enabled Corrective action Perform the Import after setting the HTTPS to Disable in the MMB Web UI Network Protocols window Severity Warning 00453 SSH Server Key is generated successfully To install this new SSH Server Key click OK button Meaning The SSH Server Key was successfully created To insta
79. 540 05 MMB Messages W_00606 Select a Group Name Meaning User Group is not selected Select a Group Name Corrective action Select a Group Name Severity Warning E 00607 Same name already exists Group addition failed Meaning Group addition failed because same name already exists Corrective action Change the name of new group Severity Error E 00608 No more Group addition Meaning A group cannot be created because the number of existing group is the maximum Corrective action If a new group is needed delete an existing group Severity Error E 00609 Unable to change the status to Disable because the specified group is last Administrator Meaning The status is unable to change disable because the specified group is last Administrator Corrective action LDAP is enabled one or more groups with privilege of Administrator are needed When if you delete the group disable LDAP Severity Error E 00610 Unable to change the privilege because the specified group is last Administrator Meaning The Group is unable to change the privilege because the specified group is last Administrator LDAP is enabled one or more groups with privilege of Administrator are needed Corrective action When if you change the privilege of the group disable LDAP or make another Group with privilege of Administrator Severity Error 00611 Group addition was completed Meaning This is message that t
80. 7 Diag Error Status Register Error Meaning A CPLD Initmode register error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 18 CA92344 0540 05 MMB Messages 150703C4 Diag L2 Cache Correctable Error did not occur Meaning The L2 cache correctable error could not be detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150703D4 Diag L2 Cache Tag Parity Error Meaning An L2 cache tag parity error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 28070020 User Port connected Meaning A Link Up was detected in the MMB User Port Corrective action No action is necessary Severity Info 28070121 User Port 0 disconnected Meaning The User Port 0 LAN of the MMB was disconnected Corrective action Check the LAN cable of the User Port Severity Warning 28070122 User Port 1 disconnected Meaning The User Port 1 LAN of the MMB was disconnected Corrective action Check the LAN cable of the User Port Severity Warning 28070810 User Port 0 activated Meaning User Port 0 of the MMB has entered the Link Up state Corrective action No action is necessary Severity Info 28070811 User Port 1 activated Meaning User Port 1 of the MMB has e
81. 92344 0540 05 MMB Messages 12039 Adapter error Adapter failed to init mbxCmd READ_CONFIG Meaning Initialization of the adapter failed Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12040 Adapter error Adapter failed to mbxCmd INIT_LINK Meaning Initialization of the adapter failed Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12041 Adapter error Adapter Hardware Error Meaning An interrupt that indicates a hardware fault was received Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12064 Adapter error Suspect any fixed hardware failure Meaning An HBA reset was tried after a parity error was detected but the operation ran out of retries The HBA is blocked PC error recovery Corrective action An HBA or a PCI bus in the system has a fault Replace the adapter Severity Warning 12070 Adapter error Adapter reset failed Meaning When a PCI error was detected HBA Reset was executed but it failed PC error recovery Corrective action The HBA must be replaced because it has a fault Contact your sales representative or a field engineer Severity Warn
82. 98 Failed to get aa Meaning Acquisition of aa data has failed Data acquisition for window display has failed Corrective action If the problem persists even after selecting the menu again contact your sales representative or a field engineer Severity Error E 00100 Failed to set aa Meaning aa setting has failed Displayed when the process of setting from a window has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error E 00101 Unable to power on the Partition aa due to CPU mismatch between SBs Meaning Partition aa could not be powered on as there was mismatch of CPUs mounted between the SBs Corrective action Make sure that the CPUs mounted on the SBs on which the partition has been configured are the same Severity Error E 00107 Unable to power on the chassis Meaning The system chassis is not in a status in which the power can be turned on Corrective action Wait for some time and turn on the power again Severity Error E 00108 Unable to power off the chassis Meaning The system chassis is not in a status in which the power can be turned off Corrective action Wait for some time and turn off the power again Severity Error E 00109 Unable to force power off Meaning Force Power Off cannot be executed in the present state Corrective action Wait for some time and execute Force Power
83. A reg Meaning An error occurred during restoration of HCA register Corrective action Replace IB HCA card Severity Warning 18027 Couldn t restore HCA COMMAND Meaning An error occurred during restoration of HCA COMMAND Corrective action Replace IB HCA card Severity Warning 106 CA92344 0540 05 MMB Messages 18028 PCI device did not come back after reset Meaning Device failed to start after reset Corrective action Replace IB HCA card Severity Error 18029 Failed to reset HCA Meaning An error occurred during reset of HCA Corrective action Replace IB HCA card Severity Error 18030 Failed to initialize Meaning An error occurred during initialization Corrective action Replace IB HCA card Severity Error 18048 NOP command failed to generate interrupt Meaning An error occurred during interruption Corrective action Replace IB HCA card Severity Warning mPCle SSD Linux related 19000 Adapter error Internal error 800GB card Meaning Internal error has occurred Corrective action Replace the PCle SSD card Severity Warning 19001 Adapter error Write performance reduced 800GB card Meaning Write performance is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 107 CA92344 0540 05 MMB Messages
84. B must be replaced Contact your sales representative or a field engineer Severity Error 150702AD Diag MRAM Write read Error Meaning A MRAM Write Read error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150702BA Diag TSEC Internal Loopback Error Meaning Loop back error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150702BB Diag NIC EEPROM Error Meaning A data error was detected in the NIC setting EEPROM Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150702CA Diag TSEC Internal Loopback recv error Meaning Loop back error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150702DA Diag TSEC Internal Loopback send error Meaning A loop back data was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150702DB Diag NIC Send Error Meaning Loopback data sending has failed Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15 CA92344 0540 05 MMB Messages 150702EB Diag NIC Register Error Meaning A register read err
85. C EEPROM Corrective action Replace the SB Severity Error sWindows OS related BMC BO1FOOFF Boot from floppy disk completed Meaning Booted Corrective action No action is necessary Severity Info BO1FO1FF Boot from hard drive completed Meaning Booted Corrective action No action is necessary Severity Info BO1FO02FF PXE boot completed Meaning Booted Corrective action No action is necessary Severity Info BO1FOS3FF Diagnostic boot completed Meaning Booted Corrective action No action is necessary Severity Info BO1FO4FF Boot from CD ROM completed Meaning Booted Corrective action No action is necessary Severity Info BO1FO05FF ROM boot completed Meaning Booted Corrective action No action is necessary Severity Info 32 CA92344 0540 05 MMB Messages BO1FO6FF Boot from unspecified boot device completed Meaning Booted Corrective action No action is necessary Severity Info B02000FF Critical stop during OS load or initialization Meaning The OS has stopped abnormally Corrective action The software needs to be examined Severity Warning B02001FF Operating system critical stop during run time Meaning The OS has stopped abnormally Corrective action The software needs to be examined Severity Warning B02002FF Operating system graceful stop Meaning The OS has stopped normally Corrective act
86. Check if there is any error in the USB1l VGA USB2 I PCI Slot specification Also check the Partition configuration Severity Warning Partition x does not include the specified GBE PCI SLOT DU Meaning The specified ABE IPCI SLOT IDU is not included in the Partition Corrective action Check the Partition configuration Severity Warning Partition x does not include the specified PCI BOX PCI SLOT Meaning The specified PCI BOX PCI SLOT is not included in the Partition Corrective action Check if there is any error in the PCI BOX PCI SLOT specification Also check the Partition configuration Severity Warning Unable to change partition configuration because this partition is powered on Meaning The partition cannot change the partition configuration because of the state of Power On Corrective action Turn off the power of the specified partition Severity Warning Unable to execute this command because PCI Bus mode TPM Fixed mode of the Partition 0 is Enabled Meaning DR cannot be enabled because the function that cannot coexist with DR function is enabled Corrective action Please confirm the setting of partition that DR function will be enabled Please set to bellow setting of partition that DR function will be enabled Please set the partition that makes the DR function effective as follows PCI Address Mode PCI Segment Mode TPM Disabled pci express mode flexible Failed to ex
87. Corrective action Disconnect the excess PCI Boxes Severity Warning 1B6F0110 Incorrect connection Invalid PCI Box ID Meaning An invalid ID has been defined for the PCI Box connected to the indicated port Corrective action Check the ID switch on the PCI Box Severity Warning 1B6F0120 Incorrect connection PCI Box ID repetition Meaning The ID of the PCI Box which is connected to the indicated port is duplicated with the ID of the PCI Box connected to another port Corrective action Check the ID switch on the PCI Box Severity Warning 1B6F0130 Incorrect connection Cable failure Meaning Cable failure of the PCI Box cable connected to the indicated port Corrective action Check the cable connected to the PCI Box Severity Warning 1B6F0140 Incorrect connection Cable unmatch Meaning Unmatch of the PCI Box cable connected to the indicated port Corrective action Check the cable connected to the PCI Box Severity Warning 23 CA92344 0540 05 MMB Messages 1B6F0150 Incorrect connection Illegal disconnect Meaning The PCI Box cable connected to the indicated port may be removed when the related partition is power on Corrective action Check the cable connected to the PCI Box Severity Warning 1B6F01A0 Invalid ID SW operation Meaning Incorrect operation of the ID switch Corrective action Restore the ID switch on the PCI Box to its original setting Severity
88. ERR 406 cpu lt x gt status is invalid offline Meaning The state of added CPU x is invalid so CPU lt x gt is disabled Corrective action Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 407 memory lt x gt status is invalid offline Meaning The state of added memory x is invalid so memory lt x gt is disabled Corrective action Please gather the information for investigation by using opt FJSVar util sbin dr report on the partition side and contact the technology of our company member dr util ERR 408 cpu lt x gt status is invalid online Meaning The state of invalidated CPU lt x gt was invalid so CPU x is still enabled Corrective action Please gather the information for investigation by using opt FJSVar util sbin dr report on the partition side and contact the technology of our company member dr util ERR 409 memory lt x gt status is invalid online Meaning The state of invalidated memory lt x gt was invalid so memory lt xz is still enabled Corrective action Please gather the information for investigation by using opt FJSVar util sbin dr report on the partition side and contact the technology of our company member dr util ERR 420 Failed to remove CPU lt x gt with error lt y gt Meaning Failed to remove cpu lt x gt with error number y Corrective a
89. EST 2000 CA92344 0534 General Description series SPARC Enterprise PRIMEQUEST Provides the necessary information and concepts you should C120 H007EN Common Installation Planning understand for installation and facility planning for SPARC Manual Enterprise and PRIMEQUEST installations PRIMEQUEST 2000 Series Includes the specifications of and the installation location CA92344 0535 Haraware Installation Manual requirements for the PRIMEQUEST 2000 series PRIMEQUEST 2000 Series Describes how to set up the PRIMEQUEST 2000 series server CA92344 0536 Installation Manual including the steps for installation preparation initialization and software installation PRIMEQUEST 2000 Series User Describes how to use the Web UI and UEFI to assure proper CA92344 0538 Interface Operating Instructions operation of the PRIMEQUEST 2000 series server PRIMEQUEST 2000 Series Describes how to use tools and software for system administration CA92344 0537 Administration Manual and how to maintain the system component replacement and error notification PRIMEQUEST 2000 Series Tool Provides information on operation methods and settings including CA92344 0539 Reference details on the MMB and UEFI functions PRIMEQUEST 2000 Series Lists the messages that may be displayed when a problem occurs CA92344 0540 Message Reference during operation and describes how to respond to them viii CA92344 0540 05 Overview of Messages
90. Error 2C6F0706 FRU Comm Lost By Local Failure Meaning The 12C bus has failed hang Corrective action Target board must be replaced Severity Error 2C6F07FF FRU Communication Lost Meaning An I2C error has occurred Corrective action Target board must be replaced For IOU 0 or OU 1 When the situation does not improve it even if target board is replaced replace DU 0 For IOUZ2 or OU 3 When the situation does not improve it even if target board is replaced replace DU 1 Severity Error 2CEFOOFF FRU Installed Meaning The component has been mounted Corrective action No action is necessary Severity Info 26 CA92344 0540 05 MMB Messages 2 1 12 BMC related The BMC related messages are listed below mTemperature Sensor related BMC B0010571 CPU 0 Temp Temperature high warning C Meaning A temperature rise Warning was detected Corrective action If the Inlet Temp is normal and CPU Temp is abnormal please check the state of the filter the heat sink and installation environment Severity Warning B0010572 CPU 1 Temp Temperature high warning C Meaning A temperature rise Warning was detected Corrective action If the Inlet Temp is normal and CPU Temp is abnormal please check the state of the filter the heat sink and installation environment Severity Warning B0010591 CPU 0 Temp Temperature high critical C Meaning A temperature r
91. I DM IRL IUE CIN LESS 2 1 9 PEXU related 2 1 10 Subsystem related 2 1 11 PRU related I RR 25 2 1 12 BMG related D D P 27 2 1 13 SYSTEM Status Sensor related tera pete eleg duse gets etdiqeletipe usi esperas 2 1 14 MMB firmware related eene Et re HER ee eR ne eed 2 1 15 CPU Memory Scale up Controller Memory Buffer related 2 1 16 POL Express related 5 needed Manei uim uu Mui II 2 1 17 Module related TD Eae EEEE EEA EEE E EEE EAEE E EAEE EEEE EEEE 2 1 18 RAID Related ict n Aurich au t n tut cn e nd c Ru ts 60 2 1 19 JX40 Related eMe 67 2 1 20 Maintenance mode related ierit erre e Min DX neni AE Lr Re Mun Edere ec ren 73 2 1 21 Power Saving related 2s its 2 1 22 SSD related oce et eb ace p a pe eb c p Rn db iri UR eeepc ca 2 2 List of SVAS message IDs ni e tates Dicto tete a e n aor Dee Dee state i e eet Deuce deer te 77 2 2 1 Dinuxrelated 5 iret ERR DR inum iul eui mic pL 77 2 2 2 Windows related s SENSE e eS 112 2 3 List Of CLIIMESSAQES ioc ces oen tad iln nte eo rec hanna dene ao de coa Deb tope ebat creto 125 24 Window Display Error Messadg6s 3 eorr teniente ien HEU E ORE ACH EROR ba e RCM PE Fe HER Meade iai 152 CHAPTER 3 Dynamic Reconfiguration Messages seseeseeeeneneennenn tenente nennen nennt 198 3 1 Messages concerning incomplete system environ
92. LED operation Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 17 CA92344 0540 05 MMB Messages 150703A0 Diag System Timer Operation error Meaning The System Timer operation is not normal Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150703A2 Diag SDRAM Uncorrectable Error Meaning Uncorrectable error has occurred Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150703A4 Diag L2 Cache Uncorrectable Error Meaning An L2 cache uncorrectable error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150703A7 Diag CPLD Initmode Register Error Meaning A CPLD register error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150703B2 Diag SDRAM Memory Error Meaning An SDRAM data error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150703B4 Diag L2 Cache Memory Error Meaning An L2 cache memory error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150703B
93. Meaning Temperature problem of FBU on RAID controller detected Corrective action 1 Please confirm the temperature of ambient is in a regulated value 2 When the problem is not canceled it is necessary to exchange the FBU Severity Warning 65 CA92344 0540 05 MMB Messages 297F0502 BBU on RAID controller removed Meaning The voltage has decreased remarkably Corrective action Please confirm firmware version of the RAID controller and update latest version Please wait for the charge completion of the battery Please exchange FBU when the problem is not canceled after the charge is completed Severity Warning 297F0503 BBU on RAID controller BBU charger problem detected SOH bad Meaning The charge with the battery is insufficient Corrective action Please exchange FBU Severity Warning 297F0504 BBU on RAID controller Error with the remote BBU connector cable detected Meaning Problem of the cable of FBU was detected Corrective action Please exchange the cable of FBU Severity Warning 297F0505 BBU on RAID controller requires reconditioning please initiate recalibration Meaning The reconditioning of the battery is necessary Corrective action 1 Please do the recalibration Please do not interrupt the charge by reboot and shutdown 2 When the problem is not canceled it is necessary to exchange the FBU 3 When the problem is not canceled please gather the survey material becaus
94. Meaning There is no response from enclosure 96s is disk enclosure model name Corrective action 1 Please confirm the cable of enclosure 2 Please confirm that enclosure is operating 3 If the problem persists please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C9A10FA6 Enclosure SAS SATA mixing not supported PCIBox or IOU n Slot n Port n Cascade 96s Meaning Mixing of SAS and SATA is not supported 96s is disk enclosure model name Corrective action Please confirm configuration of physical drive of enclosure Severity Warning C9A10FA7 Enclosure firmware download failed PCIBox or IOU n Slot n Port n Cascade s Meaning The firmware update failed s is disk enclosure model name Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C9A10FA8 Enclosure communication lost PCIBox or IOU n Slot n Port n Cascade s Meaning The connection to enclosure is down s is disk enclosure model name Corrective action 1 Please confirm the cable of enclosure 2 Please confirm that enclosure is operating 3 If the problem persists please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning 72 CA92344 0540 05
95. Memory Mode requirements Corrective action Check the location and mix status of the DIMM mounted on the SB Severity Error W 00492 Unable to register the specified SB d as a Reserved SB due to Partition is Fixed I O Mode Meaning The specified SB cannot be registered as a Reserved SB because the partition is a fixed I O mode Corrective action Check the PCI Express Mode settings of the partition Severity Warning W 00493 Unable to register the specified SB d as a Reserved SB due to abnormal DIMM composition Meaning The specified SB cannot be registered as a Reserved SB because the DIMM configuration is abnormal Corrective action Check the location and the mix status of DIMM mounted on the SB Severity Warning 186 CA92344 0540 05 MMB Messages 00494 The DIMM does not satisfy requirements of Mirror Mode If you register the specified SB s as a Reserved SB Mirror Mode will be disabled when switching to specified SB Are you sure to continue Meaning DIMM does not satisfy the requirements of the Mirror Mode When SB s thus specified is registered as a Reserved SB the Mirror Mode will be canceled when switching to the Reserved SB The message asks for confirmation to continue processing Corrective action To continue the setting click the OK button in the confirmation dialog box To terminate the setting click the Cancel button in the confirmation dialog box Severity Info W 00495 Un
96. Mode Meaning The specified partition could not be powered on as the DIMM does not meet the Mirror Mode requirement Corrective action Check the status of the DIMM of the SB that is incorporated in the specified partition Severity Error Unable to register the specified SB d as a Reserved SB due to Partition d is Fixed I O Mode Meaning Unable to register in the Reserved SB since the Fixed I O mode has been set Corrective action Check the PCI Express Mode of the specified partition Severity Warning Unable to register the specified SB d as a Reserved SB due to abnormal DIMM composition Meaning Unable to register the SB as a Reserved SB since there is an error in the DIMM configuration Corrective action Check the status of the DIMM which is mounted on the SB Severity Warning The DIMM does not satisfy requirements of the Mirror Mode If you register the specified SB s as a Reserved SB the Mirror Mode will be disabled when switching to specified SB Are you sure to continue Y N Meaning An attempt was made to set the Mirror Mode for a partition in which the SB with a DIMM configuration that does not meet the SB requirement has been assigned as a Reserved SB If the setting is continued the Mirror Mode would be cancelled when switched to the Reserved SB but there will be a confirmation for continuing the settings Corrective action To continue with the setting enter Y To interrupt the setti
97. OU_ dGbE Meaning Lane degradation was detected in the Onboard GbE SAS PCI card or SAS RAID card Corrective action The target SB IOU DU PCI Box or the PCI card must be replaced Contact your sales representative or a field engineer Severity Warning C8A90505 PCI Express Speed degraded VendorlDz9 604x DevicelD 04x SubvendorlID 04x Subsystem 04x on IOU_ dGbE Meaning Speed degradation was detected in the Onboard GbE SAS PCI card or SAS RAID card Corrective action The target SB IOU DU PCI Box or the PCI card on IOU PCI Box must be replaced Contact your sales representative or a field engineer Severity Warning 2 1 17 Module related The messages related to the module are listed below C9A10290 BMC Communication Error Meaning There was error in a BMC Corrective action The system board must be replaced If the error persists the Active MMB must be replaced Severity Warning 59 CA92344 0540 05 MMB Messages 2 1 18 C9A30290 BMC Communication Failure Meaning The error could not be resolved by BMC reset Corrective action The system board must be replaced If the error persists the Active MMB must be replaced Severity Error RAID Related The messages related to the RAID are listed below C8A10D00 RAID Card Uncorrectable error VendorlD 04x DevicelD 04x SubvendorlD 04x Subsystem 04x on IOU_ dGbE Meaning RAID Card Uncorrectable error has occurred Corrective action
98. Off again Severity Error 159 CA92344 0540 05 MMB Messages E 00110 PRIMEQUEST2800B2 2800B Failed to add the SB or IOU to the partition Meaning Addition of SB or IOU to the partition has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error PRIMEQUEST2400E2 2800E2 2400E 2800E Failed to add the SB IOU or Extended Partitioning to the partition Meaning Addition of SB IOU or Extended Partitioning to the partition has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error E 00111 PRIMEQUEST2800B2 2800B Failed to remove the SB or IOU from the partition Meaning Removal of SB or IOU from the partition has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error PRIMEQUEST2400E2 2800E2 2400E 2800E Failed to remove the SB IOU or Extended Partitioning from the partition Meaning Removal of SB IOU or Extended Partitioning from the partition has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error E 00112 Unable to add the specified SB aa to the partition due to CPU mismatch between SBs Meaning SB aa cannot be included in the partition because the CPUs mounted between the SBs are different
99. Severity Error W 00403 Invalid character is included in Password Meaning The Password includes an invalid character Corrective action Enter the correct Password Severity Warning W 00404 Password differs from the re password Meaning The entered two passwords or pass phrases do not match with the changed password and confirmed password Corrective action Check the Password Severity Warning W 00406 Invalid character is included in User Name Meaning The user name includes an invalid character Corrective action Enter the correct username Severity Warning 175 CA92344 0540 05 MMB Messages W_00407 Input characters are too long Meaning The entered character string is too long Corrective action Recheck the entered data Severity Warning E 00408 Partitions are not selected Please select at least one partition Meaning Displayed when a user with Partition Operator privilege attempts to operate without specifying the partition to be managed Corrective action The Partition Operator must specify at least one partition to be managed Severity Error E 00409 Unable to change the privilege because the specified user is last Administrator Meaning Displayed when an attempt is made to change the privilege of the sole System Administrator to other than Admin Action Do not change the privileges Severity Error 00410 9eaa will be added Are you sure
100. Severity Error 21 CA92344 0540 05 MMB Messages 2 1 8 PCI Box related The PCI Box related messages are listed below 180700FF Transition to OK Meaning Normal state Corrective action No action is necessary Severity Info 180701FF Transition to Non critical from OK Meaning There has been a transition from the normal state to a warning state Corrective action Target unit must be replaced Severity Warning 180702FF Transition to Critical from less severe Meaning There has been a transition to an abnormal state Corrective action Target unit must be replaced Severity Error 180703FF Transition to Non recoverable from less severe Meaning There has been a transition to an abnormal state Corrective action Target unit must be replaced Severity Error 180800FF Device absent Meaning PCI Box is not mounted Corrective action No action is necessary Severity Info 180801FF Device present Meaning PCI Box is mounted Corrective action No action is necessary Severity Info 22 CA92344 0540 05 MMB Messages 2 1 9 PEXU related PEXU related messages are listed below 1B6FOOFF Cable is connected Meaning The IOU connection cable is connected Corrective action No action is necessary Severity Info 1B6F0100 Incorrect connection Number of PCI_Box Meaning The maximum number of PCI Boxes that can be connected has been exceeded
101. UIAGE SOBACI TIGRE nee CAUTION n ware CA92344 0540 05 Overview of Messages Notes on Handling the Product About this product This product is designed and manufactured for standard applications Such applications include but are not limited to general office work personal and home use and general industrial use The product is not intended for applications that require extremely high levels of safety to be guaranteed referred to below as safety critical applications Use of the product for a safety critical application may present a significant risk of personal injury and or death Such applications include but are not limited to nuclear reactor control aircraft flight control air traffic control mass transit control medical life support and missile launch control Customers shall not use the product for a safety critical application without guaranteeing the required level of safety Customers who plan to use the product in a safety critical system are requested to consult the Fujitsu sales representatives in charge Storage of accessories Keep the accessories in a safe place because they are required for server operation Adding optional products For stable operation of the PRIMEQUEST 2000 series server use only a Fujitsu certified optional product as an added option Note that the PRIMEQUEST 2000 series server is not guaranteed to operate with any optional product not certified by Fujitsu Exportation release of this pro
102. USB2I PCI Slot specification Also check the Partition configuration Severity Warning The specified IOU PCI Slot is Not present Meaning The specified IOU PCI Slot is not installed Corrective action Check for if there is any error in the IOU PCI Slot specification also check if the specified IOU PCI Slot has been installed Severity Warning The specified GbE PCI Slot DU is not free Meaning The specified GbE PCI Slot DU is already included in the Partition Corrective action Check if there is any error in the GbE PCI Slot DU specification Also check the Partition configuration Severity Warning The specified PCI Box PCI Slot is Not present Meaning The specified PCI Box PCI Slot has not been installed Corrective action Check if there is any error in the PCI Box PCI Slot specification also check if the specified PCI Box I PCI Slot has been installed Severity Warning 144 CA92344 0540 05 MMB Messages The specified PCI Slot is not free Meaning The specified PCI Slot is already included in the Partition Corrective action Check if there is any error in the PCI Slot specification Also check the Partition configuration Severity Warning Partition x does not include the specified USB1 VGA USB2 PCI Slot Meaning The specified USB11IVGA USB2I PCI Slot is not included in the Partition Corrective action
103. Unable to change the status to Disable because the specified user is the last Administrator Meaning Cannot disable as the specified user is the only system administrator Displayed when an attempt is made to delete the sole Administrator privilege user or disable the privilege Corrective action Check in the user list Severity Error E 00035 Unable to delete the user because the user is currently logged in Meaning Cannot delete a user who is logged in Corrective action Perform deletion after the relevant user has logged out Severity Error E 00036 Changing Password failed Meaning Password change has failed Displayed when the original password that was entered is incorrect Corrective action Enter the correct Password Try to change again if it fails contact your administrator Severity Error 154 CA92344 0540 05 MMB Messages 00037 Changing Password completed Meaning The password has been changed Corrective action No action is necessary Severity Info 00041 User addition was completed Meaning User addition has been completed Corrective action No action is necessary Severity Info 00042 User information editing was completed Meaning The user information has been changed Corrective action No action is necessary Severity Info 00043 User deletion was completed Meaning The user has been deleted Corrective action No action is neces
104. W 0 0 IOU 0 3 IOU_10GbE IOU 0 3 IOU_10GbE SB 2 IOU 0 3 IOU_10GbE PCle SW 0 4 IOU 0 3 IOU_10GbE IOU 0 3 IOU_10GbE SB 1 IOU 0 3 IOU_10GbE PCle SW 0 8 IOU 0 3 IOU_10GbE IOU 0 3 IOU_10GbE SB 3 IOU 0 3 IOU_10GbE PCle SW 0 12 IOU 0 3 IOU_10GbE IOU 0 3 IOU_10GbE SB 0 IOU 0 3 IOU_10GbE PCle SW 0 16 IOU 0 3 IOU_10GbE IOUZ 0 3 IOU_10GbE 210 IOU 0 3 IOU 10GbE PCle SW 1 0 IOU 0 3 IOU 10GbE IOU 0 3 IOU 10GbE IOU 0 3 IOU 10GbE PCle SW 1 4 IOU 0 3 IOU 10GbE IOU 0 3 IOU 10GbE PCle 0 Card IOU 0 3 IOU 10GbE PCle SW 1 8 IOU 0 3 IOU 10GbE IOU 0 3 IOU 10GbE DU 0 1 RAID Card 0 1 1 IOU 0 3 IOU 10GbE PCle SW 1 9 IOU 0 3 IOU 10GbE IOU 0 3 IOU 10GbE IOU 0 3 IOU 10GbE PCle SW 1 10 IOU 0 3 IOU 10GbE IOU 0 3 IOU 10GbE PCle 2 Card IOU 0 3 IOU 10GbE PCle SW 1 12 IOU 0 3 IOU_10GbE IOU 0 3 IOU_10GbE PCle 1 Card IOU 0 3 IOU_10GbE PCle 0 Card PCle 0 Card PCle 0 Card IOU 0 3 IOU 0 3 IOU_10GbE PCle 1 Card PCle 1 Card PCle 1 Card IOU 0 3 IOU 0 3 IOU_10GbE PCle 2 Card PCle 2 Card PCle 2 Card IOU 0 3 IOU 0 3 IOU_10GbE Onboard LAN IOU 0 3 IOU_10GbE IOU 0 3 IOU_10GbE DU 0 1 RAID Card RAID Card RAID Card IOU 0 3 1 PCI Boxtt 0 3 PCle SW 0 0 PCI Boxst 0 3 PCI Boxtt 0 3 IOU 0 3 2 PCI Box
105. Warning 89 CA92344 0540 05 MMB Messages 13020 Adapter error IOC msg unit reset failed Meaning An IOC Message Unit Reset request sent to the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13021 Adapter error IO unit reset failed Meaning An IO Unit Reset request sent to the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13022 Adapter error Wait IOC READY state timeout Meaning The state did not change to IOC READY even after a wait for the specified time 15 seconds Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13023 Adapter error Can t get OCFacts IOC NOT READY Meaning The IOCFACTS request cannot be executed because the adapter is in the NOT READY state Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13025 Adapter error Invalid IOC facts reply Meaning The response to an IOCFACTS request is invalid Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning
106. a perform cleaning and replace the media 4 Hard Error Replace the device 5 Illegal Request Examine the software 6 Unit Attention This is notification information from various devices e g reset status degradation 7 Data Protect Check the Write Protect status 8 Blank Check Check tape and other operations 9 Aborted Command Investigate problems in the SCSI bus and Fibre Channel transmission paths Severity Warning 14067 Software error Device configuration error Meaning An error occurred in the device configuration Although settings permit response to an X byte INQUIRY an INQUIRY command of X bytes failed Corrective action The information set using echo vendor model flag gt proc scsi device info may be incompatible with the hardware Confirm the settings If the settings are correct a SCSI device failure may have occurred Severity Warning 102 CA92344 0540 05 MMB Messages 14068 Device error inquiry failed Meaning A device error occurred Corrective action Replace or remove the device Severity Warning 14070 Device error Device configuration error Meaning The number of LUNs reported by the device exceeds the supported limit of the operating system Corrective action Set a larger value in max_scsi_report_luns or reduce the number of LUNs on the device side Severity Warning 14071 Device error Device configuration error Meaning An error occurred in the
107. able to power on the partition d due to DIMM does not satisfy requirements of Mirror Mode After checking SB status and configuration please come back to the Replacement Instruction Window and reinstall the unit Meaning Partition d cannot be powered on because the DIMM configuration does not met the requirements for the Mirror Mode settings Check the SB configuration and retry the replacement process in the Replacement Instruction window Corrective action Check in the currently displayed window if there is any problem in the DIMM configuration Return to the replacement instruction window and perform the replacement again Severity Warning W 00496 Unable to power on the partition d due to CPU composition abnormal After checking SB status and configuration please come back to the Replacement Instruction Window and reinstall the unit Meaning Partition d cannot be powered on because there is a problem in the CPU configuration Check the configuration of the SB and retry the replacement process in the Replacement Instruction window Corrective action Check in the currently displayed window if there is any problem in the CPU configuration Return to the replacement instruction window and retry the replacement process Severity Warning E 00497 Unable to register the specified Partition s as Mirror Mode enable because the CPU mismatch between SBs Meaning Mirror Mode cannot be set for partition d because
108. abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error is invalid character Meaning is an invalid character Corrective action Check the command parameter Severity Warning url is length over Meaning Unable to process since the length of the URL exceeds the specified value 128Byte Corrective action Check the command parameter Severity Warning Error Specified file does NOT correspond to this model type Meaning An unsupported model firmware file has been specified Corrective action Check the specified file Severity Error Error Specified file does not correspond to this model type Meaning An unsupported model firmware file has been specified Corrective action Check the specified file Severity Error 134 CA92344 0540 05 MMB Messages Error The chassis information could not be retrieved Meaning The OPL FRU could not be acquired Corrective action Replace the OPL Execute the Unified Firmware Update after the completion of the maintenance operation Severity Error Error The chassis information is invalid Meaning The OPL FRU setting value is incorrect Corrective action Replace the OPL Execute the Unified Firmware Update after the maintenance operation Severity Error Unified Firmware Version XX update status complete
109. action Please confirm SB number and the configuration of DIMM If the firmware version of specified SB is different from the version of the specified partition update firmware of specified SB If system is updating of firmware wait for completing of firmware update Failed to create DR test partition Meaning DR test partition cannot create Corrective action Retry the process If it fails contact your sales representative or a field engineer Unable to power on the DR test partition Meaning Power of the DR test partition cannot turn on Corrective action Retry the process If it fails contact your sales representative or a field engineer Unable to power off the DR test partition Meaning Power of the DR test partition cannot turn off Corrective action Retry the process If it fails contact your sales representative or a field engineer Hot add SB lOU failure Meaning Hot add SB IOU cannot execute because there is Error or Warning of the specified SB IOU Corrective action Confirm message Replace it if failure of the component is found Hot add SB IOU failed Meaning Hot add SB IOU was failed because an error occurred Corrective action Please process it according to other message Failed to execute DR operation Fatal error occurred Meaning DR operation was failed because a fatal error occurred Corrective action Please process it according to other message Failed to execute
110. action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC505000 PCI Receiver Error Bus Device 0x Function 0x Meaning A transmission system error of PCI express was detected Corrective action No action is necessary Severity Info 43 CA92344 0540 05 MMB Messages BC505060 PCI Bad TLP Bus Device 0x Function Ox Meaning A transmission system error of PCI express was detected Corrective action No action is necessary Severity Info BC505070 PCI Bad DLLP Bus Device 0x Function 0x Meaning A transmission system error of PCI express was detected Corrective action No action is necessary Severity Info BC505080 PCI Replay Num Rollover Bus Device 0x Function 0x Meaning A transmission system error of PCI express was detected Corrective action No action is necessary Severity Info BC5050C0 PCI Replay Timer Time out Bus Device 0x Function Ox Meaning A transmission system error of PCI express was detected Corrective action No action is necessary Severity Info BC5050D0 PCI Advisory Non fatal Bus Device 0x Function Ox Meaning An error was detected in the PCI express packet Corrective action No action is necessary Severity Info BC5050E0 PCI Correctable Internal Err
111. ales representative or a field engineer Severity Error 23201 Adapter error timeout illegal interrupt occurred Meaning The SAS driver detected a time out or abnormal interrupt Corrective action A driver adapter or HDD error may have occurred Contact your sales representative or a field engineer Severity Warning MPD Windows related 25001 Adapter or FC Network error An input output error has occurred Meaning An I O error was detected Corrective action Check the device indicated by Unit and Source in SEL of MMB Severity Error 25002 Adapter or FC Network error An input output error has occurred Meaning An I O error was detected Corrective action Check the device indicated by Unit and Source in SEL of MMB Severity Error 116 CA92344 0540 05 MMB Messages 25003 Adapter or FC Network error Some of the paths could not be detected Meaning Multipath operation could not be started for the device because of an unplugged cable or device failure Corrective action Check the device indicated by Unit and Source in SEL of MMB Severity Error 25004 Adapter or FC Network error device was removed Meaning Device became unavailable because of an unplugged cable or device failure Corrective action Check the device indicated by Unit and Source in SEL of MMB Severity Error 25005 Adapter or FC Network error An input output fault Mean
112. ally from the Standby side 15070261 HUB failure Meaning The HUB may be damaged Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070271 Uncorrectable error Meaning Uncorrectable error has occurred Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070289 Diag HUBSPI Timeout Meaning The HUB SPI serial interface has timed out Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 1507028A Diag OnChip IIC I2CARD Error Meaning A register error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 1507028B Diag NIC Loopback Error Meaning A loop back error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 1507028C Diag IIC I2CADR Error Meaning The PCA9564 IIC register could not be correctly set Control bus error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 13 CA92344 0540 05 MMB Messages 1507028D Diag MRAM Error Meaning An error was detected in the MRAM Corrective action An MMB must be replaced Contact your sales representati
113. and maintenance mode is released Severity Info W 00218 The aa firmware update has been failed bb Please write down and keep this message Meaning The firmware update process was not executed because of bb Corrective action Note down the details displayed in the dialog box Retry the firmware update process again If the same event occurs check the system event log after the replacement work is completed If the cause is unknown contact your sales representative or a field engineer Severity Warning 00219 PRIMEQUEST2800B2 2800B Unable to remove SB IOU from Partition aa because this partition is under maintenance Meaning The SB IOU cannot be removed from Partition aa as it is under maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info PRIMEQUEST2400E2 2800E2 2400E 2800E Unable to remove SB IOU Extended Partitioning from Partition aa because this partition is under maintenance Meaning The SB IOU Extended Partitioning cannot be removed from Partition aa as it is under maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info 00220 Unable to set Home on Partition aa because this partition is under maintenance Meaning Home cannot be set on Partition aa since it is under maintenance Corrective action Wait until the maintenance work is comple
114. arning C9A10F50 Insufficient operating power supplies available PCIBox n Slot n Port n Cascade s Meaning A necessary power is not being supplied s is disk enclosure model name Corrective action Confirm the PSU Severity Warning C9A10F60 Power supply n failed PCIBox n Slot n Port n Cascade s Meaning There is a possibility that the PSU breaks down 96s is disk enclosure model name Corrective action Confirm the connection of the power supply cable If there is no problem in that connection exchange the broke down PSU Severity Warning C9A10F61 Power supply n cable removed PCIBox or IOU n Slot n Port n Cascade s Meaning Cable of power supply is removed s is disk enclosure model name Corrective action Confirm the connection of the power supply cable Severity Warning C9A10F62 Power supply n turned off PCIBox or IOU n Slot n Port n Cascade s Meaning Power supply is turned off s is disk enclosure model name Corrective action Confirm the state of enclosure Severity Warning C9A10F7X Redundant power supply n failed PCIBox n Slot n Port n Cascade s Meaning The PSU broke down X is the broke down PSU number 96s is disk enclosure model name Corrective action Exchange the broke down PSU Severity Warning C9A10F80 Power supply redundancy lost PCIBox n Slot n Port n Cascade s Meaning The PSU broke down and the PSU redundancy wa
115. as occurred Corrective action For Inlet Temp Check the installation environment For PCIeSW Temp If the Inlet Temp is normal but the PCle SW Temp is abnormal check the inside and outside of the cabinet for clogged filter or waste paper being stuck that is interfering with the cooling Severity Warning 010109FF Upper Critical going high Assert 0C threshold 0C Meaning High temperature error has occurred Corrective action For Inlet Temp Check the installation environment For PCle SW Temp If the Inlet Temp is normal but the PCle SW Temp is abnormal check the inside and outside of the cabinet for clogged filter or waste paper being stuck that is interfering with the cooling When the situation does not improve it replace the unit Severity Error 01010BFF Upper Non recoverable going high Assert C threshold C Meaning High temperature error has occurred Corrective action For Inlet Temp Check the installation environment For PCle SW Temp If the Inlet Temp is normal but the PCle SW Temp is abnormal check the inside and outside of the cabinet for clogged filter or waste paper being stuck that is interfering with the cooling When the situation does not improve it replace the unit Severity Error 018100FF Lower Non critical going low Deassert C threshold C Meaning Low temperature warning was canceled Corrective action No action is necessary Severity
116. ate Corrective action Execute Unified Firmware Update after the maintenance work is completed Severity Warning W_00530 Unable to execute Firmware Update because the chassis information is invalid Meaning Unified Firmware Update cannot be executed because the FRU setting is invalid Execute Unified Firmware Update after the maintenance work is completed Corrective action Execute Unified Firmware Update after the maintenance work is completed Severity Warning 00531 Are you sure you want to clear the Partition Event Log Meaning The message asks for confirmation to clear the Partition Event Log Corrective action No action is required Severity Info 00541 Nothing is checked Meaning Nothing is checked Corrective action Check the object Severity Info 190 CA92344 0540 05 MMB Messages E 00543 Unable to power on the partition d due to abnormal Extended Partition composition Meaning The Partition cannot be powered on because of a problem in the Extended Partition configuration Corrective action Check the Extended Partition configuration Severity Error 00544 Unable to change Extended Partitioning Configuration to Partition aa because this partition is under maintenance Meaning The configuration of Extended Partitioning cannot be changed as partition aa is under maintenance Corrective action Wait until the maintenance operation is completed and the maintenance m
117. ations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19103 Adapter error Temperature above error threshold 2 0TB card Meaning Temperature exceeded the upper error threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 110 CA92344 0540 05 MMB Messages 19104 Adapter error Memory is close to wearing out 2 0TB card Meaning The product lifetime end for write operation will come soon If the device is still used it will be switched to the Read Only mode and then the data will NOT be written to the device anymore Corrective action Replace the PCle SSD card to the new one which is already purchased Severity Info 19105 Adapter error Reliability degraded 2 0TB card Meaning The reliability is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19106 Adapter error Temperature above warning threshold 2 0TB card Meaning Temperature exceeded the upper warning threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 19107 Adap
118. ble to register the specified Partition d as Mode enable because the DIMM does not satisfy requirements of Mode Meaning Unable to change the setting of the specified partition because the installation of DIMM does not satisfy requirements of Memory operation mode Corrective action Check the status of the DIMM mounted on all SBs in the partition Severity Error W 00462 The specified password is invalid Meaning The password is incorrect Corrective action Not required Severity Warning W 00463 Select a User Name Meaning Select the target user to be edited or deleted Corrective action Select the target user Severity Warning 00464 aa will be removed Are you sure Meaning User aa will be deleted The message asks whether to continue the process Corrective action Not required Severity Info 00465 A new Key and a CSR are generated successfully To use the new Key click OK button Meaning A Key and a CSR are created To use click the OK button Corrective action Not required Severity Info 183 CA92344 0540 05 MMB Messages W_00466 Login incorrect Meaning Since the Login account or password is incorrect authentication of Login has failed Corrective action Check the Login account and password and Login again Severity Warning 00467 The reboot is done Login after a while Meaning Rebooting of Active MMB has started Log in after some t
119. cessary Severity Info mMemory Module Configuration State related BMC BODF6600 DIMM Memory Mismatch in set Meaning Same memory has not been mounted Corrective action Check the memory combination Severity Warning BODF6601 DIMM Memory Unsupported Meaning Unsupported memory has been mounted Corrective action Check if the target memory is supported or not Severity Warning BODF6602 DIMM Memory Install position error Meaning There is violation in the memory mounting conditions Corrective action Check mounting position of the memory Severity Warning BODF6603 DIMM Memory SPD CRC Error Meaning An error has occurred in the memory Corrective action Replace the DIMM Severity Warning mMemory Module Related BMC BOE10F00 Memory module s changed Meaning The mounting positions were swapped Corrective action No action is necessary Severity Info 39 CA92344 0540 05 MMB Messages SDR OEM Multiple Sensor related BMC BOEE8300 ASR amp R counter exceeded restart tries Meaning The ASR counter has exceeded the number of retries Corrective action No action is necessary Severity Info uPCI related BMC BC503080 Legacy PCI Master Data PERR Bus Device 0x Function 0x Meaning Error has been detected in the PCI or PCI express data Corrective action Referring the Source and Unit of the MMB system event
120. ch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A104C8 PCle SW Downstream Blank Serial EEPROM Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10449 PCle SW Upstream Serial EEPROM Rollover Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A104C9 PCle SW Downstream Serial EEPROM Rollover Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A1044A PCIeSW Upstream EEPROM CAR Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A104CA PCle SW Downstream EEPROM CAR Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10F00 Undetermined hardware uncorrectable error Meaning The failure location
121. check error Meaning An error has occurred in BMC firmware Corrective action Download the system event log and contact your sales representative or a field engineer Severity Error 37 CA92344 0540 05 MMB Messages BOCB6800 BMC Memory Uncorrectable error Meaning A BMC error has occurred Corrective action Replace the SB Severity Error BOCB6900 BMC Memory Correctable error logging limit reached Meaning A BMC error has occurred Corrective action Replace the SB Severity Warning mCPU Status related BMC BODBO3FF CPUs CPU Uncorrectable error ECC Meaning An uncorrectable error has occurred in the CPU Corrective action Replace the CPU Severity Error BODBO4FF CPU CPU failed disabled Meaning An error has occurred in the CPU Corrective action Replace the CPU Severity Error uMemory Module Status related BMC BODE4AFF DIMM Memory Uncorrectable error ECC Meaning An uncorrectable error has occurred in the memory Corrective action Replace the DIMM Severity Error BODE4BFF DIMM Memory Error logging limit reached Meaning Correctable error logging of the memory has stopped Corrective action Replace the DIMM Severity Warning 38 CA92344 0540 05 MMB Messages BODE4CFF DIMM Memory Correctable error ECC Meaning A correctable error has occurred in the memory Corrective action No action is ne
122. co FUJITSU FUJITSU Server PRIMEQUEST 2000 Series Message Reference CA92344 0540 05 Overview of Messages Preface This manual describes the functions and features of the PRIMEQUEST 2000 series The manual is intended for system administrators For details on the regulatory compliance statements and safety precautions see the PRIMEQUEST 2000 Series Safety and Regulatory Information CA92344 0523 Organization of this manual This manual is organized as follows CHAPTER 1 Message Overview Chapter 1 describes how to read PRIMEQUEST 2000 series messages CHAPTER 2 MMB Messages Chapter 2 lists MMB messages by type CHAPTER 3 Dynamic Reconfiguration Messages Chapter 3 lists Dynamic Reconfiguration messages CHAPTER 4 sadump Messages Chapter 4 lists sadump messages Appendix A Replacement component list Appendix A lists replacement component for Unit Source in MMB SEL message i CA92344 0540 05 Overview of Messages Revision History Edition Date Revised location type Description The edition is initialized to 01 for changing manual code 1 2014 08 12 All pages X T Added descriptions about Extended Partitioning function 2 2014 10 07 CHAPTER2 MMB Messages Secure Boot 3 2015 02 03 CHAPTER2 MMB Messages RHEL7 Added descriptions about PRIMQUEST 2400E2 2800E2 4 2015 05 01 All pages 2800B2 Added descriptions about LDAP 5 2015 09 29 CHAPTER2 MMB Messages Um Added d
123. ction The remove of CPU lt x gt failed because of the error y Please try removing of SB again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 421 Faild to remove CPU x total lt y gt Meaning Failed to remove CPU x total lt y gt Corrective action The remove of CPU lt x gt of the total y gt piece failed Please try removing of SB again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 422 Failed to remove memory lt x gt with error lt y gt Meaning Failed to remove memory lt x gt with error number y Corrective action The remove of memory lt x gt failed because of the error y Please try removing of SB again When the improvement is not seen even if it executes it again please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 423 Failed to remove MEM lt x gt total lt y gt Meaning Failed to remove memory x total y kB Corrective action The remove of memory lt x gt of the total
124. ctive action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13049 Adapter error IOC says it doesn t support F W download Meaning A response that invalidates the download request sent to firmware was received Firmware download is not supported Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13050 Adapter error IOC says IOC BUSY Meaning A busy response to the firmware download request was received Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13051 Adapter error IOC returned bad status Meaning An Other error response to the firmware download request was received Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13078 Adapter error Busy with IOC Reset Meaning The adapter is performing IOC Reset and is in the busy state Corrective action Collect the data for investigation dump or fjsnap Contact your sales representative or a field engineer Replace the adapter Severity Warning 13106 Adapter error IOC issue of TaskMgmt failed Meaning Issuing a SCSI Task Management request failed Corrective ac
125. d Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 29067 Adapter error Adapter removed 1 6TB card Meaning Adapter is removed Corrective action Replace the PCle SSD card Severity Warning 123 CA92344 0540 05 MMB Messages 29110 Adapter error Internal error 2 0TB card Meaning Internal error has occurred Corrective action Replace the PCle SSD card Severity Warning 29111 Adapter error Write performance reduced 2 0TB card Meaning Write performance is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 29112 Adapter error Write operations disabled 2 0TB card Meaning Write operations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 29113 Adapter error Temperature above error threshold 2 0TB card Meaning Temperature exceeded the upper error threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 29114 Adapter error Memory is close to wearing out 2 0TB card Meaning The product lifetime end for write o
126. d Meaning Number of unified versions XX firmware update is terminated normally Corrective action No action is necessary Severity Info Unified Firmware Version XX update status not executed Meaning Number of unified versions XX firmware update has not been executed Corrective action No action is necessary Severity Info Unified Firmware Version XX update status updating YY Meaning Number of unified versions XX the firmware updating is in progress YY Corrective action No action is necessary Severity Info Unified Firmware Version XX update status failed Meaning Number of unified versions XX firmware update has failed Corrective action Check the System Event Log for errors and try updating the firmware again Severity Error The specified SB aa cannot be registered as a Reserved SB The specified SB aa cannot be registered as a Reserved SB Corrective action Try setting again If it fails contact your field engineer Severity Error Failed to execute show partition name command Meaning The show partition name command has terminated abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error 135 CA92344 0540 05 MMB Messages Password changed Meaning The password has been changed Corrective action No action is necessary Sev
127. d SB the Mirror Mode will be canceled when switching over to the Reserved SB There is a message prompt for continuing with the process Corrective action To continue the setting enter Y To interrupt the setting enter N Severity Info Failed to ntpq command Meaning The show ntpq command process has failed Corrective action Retry the process if it fails contact your sales representative or a field engineer Severity Error Unable to execute this command because Extended Partitioning mode of the Partition x is Enabled Meaning This process cannot be executed for a PPAR partition in which the setting of the Extended Partitioning mode has been enabled Corrective action Check the processing target partition Severity Warning Unable to execute this command because the Partition x is Extended partition Meaning This process cannot be executed for an Extended partition Corrective action Check the processing target partition Severity Warning Unable to execute this command because the Partition x is not Extended partition Meaning This process cannot be executed for a PPAR partition Corrective action Check the processing target partition Severity Warning Unable to set configuration because this partition is not Extended partition Meaning This process cannot be executed for a PPAR partition Corrective action Check the processing target partition Severity Warning
128. dapter Severity Warning 77 CA92344 0540 05 MMB Messages 11603 Adapter error NVM Read Error while reading MAC address Meaning An NVM read error was detected during reading of a MAC address Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11610 Adapter error pattern test reg failed Meaning The pattern test failed Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11611 Adapter error set check reg test failed Meaning The register test failed Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11612 Adapter error failed STATUS register test Meaning The STATUS register test failed Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11615 Adapter error Cannot do PHY loopback test when SoL IDER is active Meaning The PHY loopback test cannot be executed Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11701 Adapter error The NVM Checksum Is Not Valid Meaning An NVM checksum error was detected Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11702 Adapter error Hardware Error Meaning A hardware error was detected Corrective action An adapter failure may have occurred
129. del name Corrective action No action is necessary Severity Info 67 CA92344 0540 05 MMB Messages E76F0602 Physical disk n Global hot spare assigned model m PCIBox or lOU n Slot n Port n Cascade s Meaning A global hot spare of HDD was generated s is disk enclosure model name Corrective action No action is necessary Severity Info E76F0700 Physical disk n bad block table is full model m PCIBox or OU n Slot n Port n Cascade s Meaning Bad block table of HDD exceeded it to capacity s is disk enclosure model name Corrective action Please replace HDD Severity Warning E76F0800 Physical disk Zn shielded model m PCIBox or l OU n Slot n Port n Cascade s Meaning The HDD is shielded state s is disk enclosure model name Corrective action Please replace HDD Severity Warning E77E01XX Logical drive n partially degraded PCIBox n Slot n Port n Cascade Meaning The redundancy is kept though the logical drive did degradation XX is the logical drive number Corrective action When the rebuild is done it is likely to restore it Still when the problem continues it is necessary to exchange the HDD Severity Warning E77E02XX Logical drive n degraded PCIBox n Slot n Port n Cascade Meaning The logical drive did degradation and the redundancy was lost XX is the logical drive number Corrective action When the rebuild is done it is likely to
130. device configuration The number of LUNs reported by the device exceeds the supported limit of the operating system Corrective action Reduce the number of LUNs on the device side Severity Warning 14072 Device error Device configuration error Meaning An error occurred in the device configuration Corrective action If you need to use all LUNs the external disk unit configuration must be changed If you accept the fact that some of them will not be available no action is necessary Severity Warning 14073 Device error Unexpected response Meaning A SCSI device scan was interrupted The interrupt reason is displayed individually before this message Corrective action Some devices were not recognized Eliminate the cause Then perform a reboot Severity Warning 14116 Device error too big for this kernel Meaning The size of a block exceeds the allowable limit supported by the kernel Corrective action If a single drive is used replace the disk If an external disk unit is used examine it Severity Warning 14131 Device error Can t create sysfs link from SCSI device Meaning The configuration of a device is incorrect Corrective action Specify the configuration of the device correctly and try again Severity Warning 103 CA92344 0540 05 MMB Messages 14138 Device error Volume overflow CDB Meaning Data that could not be written to a device because it was full is left in a
131. duct Exportation release of this product may require necessary procedures in accordance with the regulations of the Foreign Exchange and Foreign Trade Control Law of Japan and or US export control laws Maintenance Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu Customers must not perform these tasks under any circumstances Otherwise electric shock injury or fire may result Newly installing or moving equipment Removing the front rear and side covers Installing and removing built in options Connecting and disconnecting external interface cables Maintenance repair and periodic diagnosis and maintenance Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu Customers must not perform these tasks under any circumstances Otherwise product failure may result PRIMEQUEST 2000 Series General Description Unpacking an optional Fujitsu product such as an optional adapter delivered to the customer Modifying or recycling the product Modifying this product or recycling a secondhand product by overhauling it without prior approval may result in personal injury to users and or bystanders or damage to the product and or other property vi CA92344 0540 05 Overview of Messages Note on erasing data from hard disks when disposing of the product or transferring it Disposing
132. e Dynamic Reconfiguration function after disabling Extended Partitioning Severity Warning W 00585 Dynamic Reconfiguration Mode cannot be set to this Partition because of PCI Bus Mode Meaning Dynamic Reconfiguration Mode cannot be set to this partition because this partition is PCI Bus Mode Corrective action Please set Dynamic Reconfiguration mode to this partition after set to PCI Segment Mode Severity Warning 192 CA92344 0540 05 MMB Messages W_00586 Dynamic Reconfiguration Mode cannot be set to this Partition because of Fixed I O Mode Meaning Dynamic Reconfiguration Mode cannot be set to this partition because this partition is Fixed I O Mode Corrective action Please set Dynamic Reconfiguration mode to this partition after set to Fixed I O Mode Severity Warning W 00587 Unable to execute Power Control because the firmware is updating Meaning Power Control can t execute because the firmware is updating Corrective action Please wait for the completion for firmware update Severity Warning W 00588 Unable to command power control because the power control operating Meaning Command can t accept because the power control is operating Corrective action Please wait for the completion for power control operating Severity Warning W 00589 Unable to change Resources because this partition is powered on Meaning Command can t accept because the partition is power on state Corrective ac
133. e HBA but it failed Corrective action Hardware or firmware has a fault Contact your sales representative or a field engineer Severity Warning 12027 Adapter error Config Port initialization error Meaning A READ NVPARM mailbox command failed during initialization of the adapter Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12029 Adapter error Adapter failed to init timeout Meaning An adapter error occurred A time out occurred in HBA initialization Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12030 Adapter error Adapter failed to init chipset Meaning An adapter error occurred A hardware error was detected during HBA initialization Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 83 CA92344 0540 05 MMB Messages 12031 Adapter error Adapter failed to init chipset Meaning An adapter error occurred A hardware error was detected during HBA initialization Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12032 Adapter error Adapter failed to i
134. e a detailed investigation is necessary for that and contact the repair chat channel Severity Warning 297F0506 BBU on RAID controller retention test failed Meaning It failed in the retention test of the battery Corrective action Please recovery according to the error message When the problem is not canceled please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning 297F0507 BBU on RAID controller communication error Meaning The communication error with FBU occurred Corrective action 1 Please confirm that data cable and power cable of FBU are correctly connected with RAID controller 2 Please confirm that latest firmware version of the RAID are installed 3 When the problem is not canceled it is necessary to exchange the FBU 4 When the problem is not canceled please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning 66 CA92344 0540 05 MMB Messages 2 1 19 JX40 Related The messages related to the JX40 are listed below E76F0200 Physical disk n SMART error model m predictive failure PCIBox n Slot n Port n Cascade s Meaning The HDD error was detected by self diagnosis s is disk enclosure model name Corrective action Replace the HDD Severity Warning Remark In this event occurs MMB firmware disconnec
135. e action Enter only alphanumeric characters Severity Warning 00430 Select a node Meaning The node has not been selected Corrective action Select a node and then click the button Severity Info W 00431 Invalid character included Meaning An invalid character has been included Corrective action Check the input data Severity Warning W 00432 Invalid IP Address specified Meaning The IP address is invalid Displayed if an invalid IP address is specified Corrective action Check the IP address Severity Warning W 00433 The duplicate IP address was found Meaning The IP address has been duplicated Corrective action Check the IP address Severity Warning W 00434 Invalid Time Format Meaning The time setup value is incorrect Corrective action Check the time that was set Severity Warning 179 CA92344 0540 05 MMB Messages W_00435 Invalid Port number Meaning Invalid setting has been done for setting the Port number Corrective action Check the Port number setting Severity Warning W_00436 Invalid Timeout value Meaning An incorrect value has been specified as the timeout value Corrective action Select a valid value Severity Warning W_00437 The duplicate IP address was found Meaning The port number is duplicated Displayed if there is duplicate Port number in the setting range of the window Corrective action Check the s
136. e action No action is necessary Severity Info 6 CA92344 0540 05 MMB Messages 2 1 3 Fan Related Fan related messages are listed below 040102FF Lower Critical going low Assert rpm threshold rpm Meaning Low FAN rpm error has occurred Corrective action Replace the target IO FAN or FANM When the situation does not improve even if FANM is exchanged replace the target PSU or FANU However when the same event occurs by two or more FAN mounted to same PSU or same FANU replace the target PSU or FANU Severity Error 040107FF Upper Non critical going high Assert rpm threshold rpm Meaning High FAN rpm warning has occurred Corrective action Replace the target IO FAN or FANM When the situation does not improve even if FANM is exchanged replace the target PSU or FANU However when the same event occurs by two or more FAN mounted to same PSU or same FANU replace the target PSU or FANU Severity Warning 040800FF Device absent Meaning FAN is not mounted Corrective action No action is necessary Severity Info 040801FF Device present Meaning FAN is mounted Corrective action No action is necessary Severity Info 040BOO0FF Fully Redundant Meaning FAN is redundant Corrective action No action is necessary Severity Info 040B03FF Non redundant Sufficient Resource Meaning FAN is non redundant Corrective action No action is necessary Ho
137. e action Wait until the maintenance work is completed and the maintenance mode is released Severity Warning 137 CA92344 0540 05 MMB Messages Current firmware is newer version Meaning Cannot rewrite in the firmware of the same or older version Corrective action A force option must be added for rewriting in the firmware of the same version or old version Severity Warning Unable to execute the online update Please try the update after the system power off Meaning Cannot update when the partition power is On Corrective action Execute after turning Off the partition power Severity Warning Unable to execute the update TPM is effective Meaning The firmware cannot be updated since the TPM function is enabled Corrective action Check the TPM setting of the partition Severity Warning Unable to execute the update Standby MMB is fault or disable Meaning The firmware cannot be updated since there is a fault in the standby MMB Corrective action Replace the standby MMB and then update the firmware Severity Warning The firmware is being updated now Meaning Firmware update is in progress Corrective action No action is necessary Severity Info Unable to register the specified SB x as a Reserved SB due to unsupported CPU configuration Meaning The specified SB cannot be registered as a Reserved SB since the CPU does not meet the mounting criteria Corrective action Check
138. e again Severity Warning 00206 Please select a maintenance mode Meaning Select a maintenance mode Corrective action Select a maintenance mode Severity Info 162 CA92344 0540 05 MMB Messages W_00206 Maintenance of this unit cannot be performed because the unit does not satisfy requirements of any of the maintenance modes Please check that the power status of partitions is Standby in the Partition Power Control Window and that there is available free units in the Partition Configuration Window Then please try again Meaning Maintenance work cannot be executed as there is no selectable maintenance mode and the maintenance criteria are not met Corrective action Check the power status of the partition in the Partition Power Control If it is On ask the system administrator to power off the partition Check in the Partition Configuration window whether the status of the unit is Free If it is not Free ask the system administrator to set it to Free After confirmation perform the maintenance operation again Severity Warning 00207 The current Serial Number is the same as the previous Serial Number Are you sure Meaning During unit replacement maintenance of units with serial numbers this message is displayed when the serial number is the same for a unit before and after replacement and the OK button is clicked in the replacement confirmation window Corrective action If there are no p
139. ecessary Severity Info C8AB1002 SSD Rated Write Endurance has reached 70 Meaning SSD Rated Write Endurance has reached 70 Corrective action Please confirm the usage condition of SSD and prepare the replacement part of SSD if necessary Severity Info C8AB1003 SSD Rated Write Endurance has reached 80 Meaning SSD Rated Write Endurance has reached 80 Corrective action Please confirm the usage condition of SSD and prepare the replacement part of SSD if necessary Severity Info C8AB1004 SSD Rated Write Endurance has reached 90 Meaning SSD Rated Write Endurance has reached 90 Corrective action Please prepare the replacement part of SSD Severity Info E76F0900 SSD Rated Write Endurance has reached 30 PCI Box or IOUZin Slotzn Port n Cascade s s Disk enclosure model name e g JX40 Meaning SSD Rated Write Endurance has reached 30 Corrective action No action is necessary Severity Info E76F0901 SSD Rated Write Endurance has reached 30 Meaning SSD Rated Write Endurance has reached 30 Corrective action No action is necessary Severity Info E76F0902 SSD Rated Write Endurance has reached 50 PCI Box or lOU n Slot n Port n Cascade s s Disk enclosure model name e g JX40 Meaning SSD Rated Write Endurance has reached 50 Corrective action Please confirm the usage condition of SSD and prepare the replacement part of SSD if necessar
140. ected unit is cleared when the OK button is clicked Severity Info 00205 Please select a unit to clear the status Meaning Displayed when the Status Clear button is clicked without selecting the status clear target All Partition Unit Unit Parts This message is not displayed if the user clicks the Skip button without any selection Corrective action Select the unit to be status cleared Severity Info W 00205 Maintenance of the unit cannot be performed using Hot Partition Maintenance because partition containing the target does not a have its OS running Check the system progress of partitions in the Partition Power Control Window Then please try again Meaning Hot Partition Maintenance process has failed because the maintenance target partition has been stopped or the operating system is not running for System Progress Check the power status of the partition and execute the process again is notified when an attempt is made to perform the Hot Partition Maintenance when the maintenance target is in the Standby status or when the operating system is not running for System Progress Corrective action Confirm in the Partition Power Control window that the operating system is running for the partition System Progress If the operating system is not running ask the system administrator to get the operating system running for the System Progress of the partition After confirming perform the maintenanc
141. ecute set partition dynamic reconfiguration p disable enable command Meaning Enabling disabling of DR function of specific partition has failed Corrective action Please confirm whether there are SB and IOU in the specific partition 145 CA92344 0540 05 MMB Messages Unable to change the mode while the partition is running Please try to change the mode after the partition is shutdown Meaning The mode cannot change while the partition is running Please try to change the mode after the partition is shutdown Corrective action Please try to change the mode after the partition is shutdown Failed to execute show partition dynamic_reconfiguration command Meaning Execution of show partition dynamic_reconfiguration command has failed Corrective action Please refer to other messages Try setting again If it fails contact your sales representative or a field engineer Are you sure to continue adding SB lOU to partition Y N Meaning This is a confirmation Corrective action Input Y if you continue Input N if you don t continue DR operation start 1 5 Meaning DR operation of SB is started Corrective action No action is necessary Assigning SB to partition 2 5 Meaning The allocation to the partition is executed Corrective action No action is necessary Testing SB 3 5 Meaning The diagnosis to the partition is executed Corrective action No action is necessary
142. ed An overrun occurred on a variable length device Corrective action If you were working on a DAT by using a command such as dd confirm that the specified parameters are correct If you are sure that there is no mistake in the work a hardware failure occurred Replace the drive Severity Warning 14025 Device or Software error Incorrect block size Meaning A device or application error occurred The block size or the size specified for read is invalid for a fixed length device Corrective action Check the block size for read If there is no problem with the block size replace the drive Severity Warning 14027 Device or Software error Partitioning of tape failed Meaning A device or application error occurred Partitioning of the tape device failed Corrective action Check whether the drive supports partitioning If the drive does not support it modify the software settings If the drive supports it replace the drive Severity Warning 101 CA92344 0540 05 MMB Messages 14054 Device error ioctl error Meaning Warning ioctl error Device or Driver problem Non removable drive some error occurred during ioctl Corrective action Identify the type of the target unit from its host id and lun Then check the sense key extended sense in the original message to determine the corrective action 1 Recovered Error If it is a removable device perform cleaning 2 Not Ready If it is non removable
143. ed WEB Session information due to WEB Session Max over Meaning Unable to connect to BMC due to exceed limited connecting number Corrective action Wait for disconnection of other user who connect to BMC Severity Warning W_00473 Unable to check the Video Redirection check box due to the Video Redirection option is disabled Meaning Unable to check the Video Redirection check box due to the Video Redirection option is disabled Corrective action Set the required option to Enable in the Console Redirection Setup window Severity Warning 00474 Unable to execute s due to resource lock Please retry after waiting awhile Meaning SEL Download or Firmware Update has been locked Retry after some time Corrective action Some of the processes that occupy resources are subject to exclusive control Try again after some time Severity Info W_00476 Unable to execute the online update Please try the update after the system power off Meaning Unable to execute the firmware update because the system power is on Corrective action Retry the update after turning off the power of all the partitions Severity Warning W_00477 Select the file of update Meaning A firmware file is not selected Corrective action Select a firmware file Severity Warning W 00478 Unable to execute the update Standby MMB is fault or disable Meaning The firmware update cannot be executed because there is a Fault
144. ed not be saved click the OK button to proceed to the next window Otherwise click the Cancel button to display this window and save the log files Severity Info 164 CA92344 0540 05 MMB Messages W 00211 The unit is not present Maintenance will be canceled Are you sure Meaning After replacement or expansion is instructed if the Next button in this window is clicked without the unit mounted the subsequent maintenance procedures are skipped to display the completion window Corrective action After the Previous button is clicked and when the replacement or expansion instruction window appears mount the target unit After completing the mounting open this window again and continue the operation Severity Warning 00212 System Power Control cannot be executed because the system is under maintenance Meaning Execution of power control is not permitted during maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info W 00212 The powering on has been skipped because there is no partition whose configuration satisfies power on requirements After Maintenance completion Check the partition configuration in the Partition Configuration Window Meaning During Cold System Maintenance an attempt was made to turn on the power to all partitions but the power could not be turned on because there were applicable partitions Corrective action
145. ed to be removed is already unavailable Please confirm whether the slot number is wrong 200 CA92344 0540 05 Dynamic Reconfiguration Messages 3 3 dr util ERR 289 IOU lt x gt device is already disabled Meaning IOU x is already unavailable Corrective action IOU x that tried to be removed is already unavailable Please confirm whether the slot number is wrong dr util ERR d Internal Error d 300 301 Meaning Internal error occurred Corrective action Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member Messages concerning trouble that occurs in the OS kernel dr util ERR 400 Failed to add cpu lt x gt with error lt y gt Meaning Add cpu lt x gt with error number y is failed Corrective action The addition of CPU lt x gt failed because of the error y Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 401 Failed to add CPU x total lt y gt Meaning Add CPU x total lt y gt is failed Corrective action The addition of CPU lt x gt of the total y gt piece failed Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr uti
146. eout of DR sequence occurred in OS processing Corrective action Please deal with it according to SEL and syslog of OS DR sequence timeout SB hot add request failure Meaning Timeout of DR sequence occurred in adding of SB Corrective action Confirm SEL Exchange the failure component if a component is failure DR sequence timeout QPI connection failure Meaning Timeout of DR sequence occurred in connecting QPI Corrective action Please execute the following 1 Download SEL and contact your sales representative or a field engineer 2 Please process it according to SEL if reset of the partition is failed Please use it continuously if reset of the partition is success Unable to power on the IOU Meaning Power On of the IOU is failed Corrective action Download SEL and contact your sales representative or a field engineer Unable to power on the PCI Box Meaning Power On of the PCI Box is failed Corrective action Download SEL and contact your sales representative or a field engineer Unable to onlining the DR target BMC Meaning Online of the specified SB is failed Corrective action Download SEL and contact your sales representative or a field engineer Unknown Error Code 0xXX Meaning DR process is failed with unknown Error Code Corrective action Download SEL and contact your sales representative or a field engineer 149 CA92344 0540 05 MMB Messages BIOS Error Code 0xXX Meaning
147. epresentative or a field engineer Severity Error C8A104C1 PCle SW Downstream No Acknowledge Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10442 PCle SW Upstream Lost Arbitration Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A104C2 PCle SW Downstream Lost Arbitration Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10443 PCle SW Upstream Other Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error 56 CA92344 0540 05 MMB Messages C8A104C3 PCle SW Downsiream Other Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10444 PCle SW Upstream Initialization Checksum Error Meaning A switch EEPROM error has occurred Corrective action The target SB IOU or PCI Box must be replaced
148. epresentative or a field engineer Severity Error E 00020 The IP address overlaps Meaning The IP address is duplicated Displayed when the IP address set in a window is duplicated with another IP address that had been set in the MMB of another window Corrective action Check the IP address Severity Error E 00022 The partition doesn t have a node Meaning There is no node in the selected partition In case of Remove Displayed when a partition is selected to remove a node and all nodes have been removed by another user In case of Home Displayed when there is no SB in the selected partition for configuring the Home or all the SBs have been removed by another user Corrective action Check the configuration Severity Error 153 CA92344 0540 05 MMB Messages 00029 Status Clear completed Meaning The status is cleared Corrective action No action is necessary Severity Info E 00031 Same name already exists User addition failed Meaning The same name is already registered The user cannot be added Displayed when an attempt is made to register a user name which is already registered Corrective action Check the user registration list Severity Error E 00032 No more User addition Meaning The user cannot be added as the upper limit of the number of user registration has been exceeded Corrective action Delete unnecessary users Severity Error E 00034
149. epts about ServerView Suite ServerView Operations Manager Installation Describes installation and update installation of ServerView Linux Agent ServerView Agents for Linux ServerView Operations Manager Installation Describes installation and update installation of ServerView Windows Agent ServerView Agents for Windows Server View Mission Critical Option User Describes the necessary functions unique to PRIMEQUEST cluster linkage Manual and ServerView Mission Critical Option SVmco which is required for supporting these functions ServerView RAID Manager VMware Describes the installation and settings required to use ServerView RAID vSphere ESXi 5 Installation Guide Manager on the VMware vSphere ESXi 5 server Modular RAID Controller Provides technical information on using SAS RAID controllers LSI MegaRAID SAS 2 0 Software RAID Ctrl SAS 6Gb 1GB D3116C LSI MegaRAID SAS 2 0 Device Driver MegaRAID SAS 9286CV 8e Installation Refer to the following URL The Fujitsu Technology Solutions manuals server htto manuals ts fujitsu com Modular RAID Controller Provides technical information on using SAS RAID controllers LSI MegaRAID SAS 3 0 Software PRAID EP400i EP420i D3216 ix CA92344 0540 05 Overview of Messages Title Description LSI Integrated RAID SAS 3 0 Solution PRAID EP420e Refer to the following URL The Fujitsu Technology Solutions manuals server htto manuals
150. erity Info change passwd failed code aa Meaning The password change has failed aa Exception code Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error Could not set attributes Meaning The setting of the terminal information has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error invalid passwd Meaning An invalid character has been used in the password Corrective action Check the command parameter Severity Warning password needs 8 characters at least Meaning At least eight characters are required in the password Corrective action Check the command parameter Severity Warning password needs 32 characters or less Meaning The password can contain up to 32 characters Corrective action Check the command parameter Severity Warning Failed to the password authentication Meaning Password authentication has failed Failure of PAM authentication start end and failure of PAM authentication process Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error 136 CA92344 0540 05 MMB Messages New password differs from Re enter new password Meaning The new password and the password entered for authentication do n
151. escriptions about RHEL6 7 CA92344 0540 05 Overview of Messages Product operating environment This product is a computer intended for use in a computer room environment For details on the product operating environment see the following manual PRIMEQUEST 2000 Series Hardware Installation Manual CA92344 0535 Safety Precautions Alert messages This manual uses the following alert messages to prevent users and bystanders from being injured and to prevent property damage personal injury if the user does not perform the procedure correctly This indicates a hazardous potentially dangerous situation that is likely to result in death or serious This indicates a hazardous situation that could result in minor or moderate personal injury if the user does not perform the procedure correctly This also indicates that damage to the product or other property may occur if the user does not perform the procedure correctly Important This indicates information that could help the user use the product more efficiently Alert messages in the text An alert statement follows an alert symbol An alert statement is indented on both ends to distinguish it from regular text Similarly one space line is inserted before and after the alert statement Only Fujitsu certified service engineers should perform the following tasks on this product and the options provided by Fujitsu Customers must not perform these tasks under any circumstances Ot
152. etting of the Port number Severity Warning W_00438 Timeout setting is invalid Meaning The timeout setting value not in the valid range Corrective action Set a valid value for the timeout Severity Warning E 00439 SSL Server Certificate is not found Meaning The server certificate for use in the HTTPS is not found Corrective action Set the HTTPS after installing the certificate Severity Error 00440 HTTP Connection will be lost You will need to login again Are you sure Meaning Disabling the HTTP HTTPS will disconnect the Web UI Displayed if an attempt is made to set the currently accessed protocol HTTP or HTTPS to Disable Corrective action Not required Severity Info W 00441 Range over error Meaning The refresh interval is outside the settable range Corrective action Check the refresh interval entered Severity Warning 180 CA92344 0540 05 MMB Messages 00444 Previous private key will be overwritten with new private key Are you sure Meaning An already registered key will be overwritten with a new key The message asks whether to continue the process Displayed as a confirmation when creating an SSL key Corrective action Not required Severity Info 00445 Private Key is exported Are you sure Meaning Retrieves the secret key The message asks whether to continue the process Corrective action Not required Severity Info 00
153. etting process executed in Hot System Maintenance Warm System Maintenance has terminated abnormally Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error E 00306 Maintenance cannot be continued because serial number could not be retrieved Check the System Event Log Window to refer to the error details Meaning The serial number could not be acquired after the replacement in the replacement of a unit with serial number or the serial number could not be acquired after the expansion in the expansion of a unit with serial number Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error 173 CA92344 0540 05 MMB Messages E 00307 Maintenance cannot be continued because Location LED could not be switched off Check the System Event Log Window to refer to the error details Meaning Error has occurred in the Location LED lighting Corrective action The completion window is displayed when the OK button of the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system
154. event log and contact your sales representative or a field engineer Severity Error E 00309 Maintenance cannot be continued because the unit is not present Check the System Event Log Window to refer to the error details Meaning The maintenance work is interrupted as no unit is mounted Corrective action Check the unit mounting status Check the system event log for any errors If the cause is unknown contact your sales representative or a field engineer Severity Error E 00312 Maintenance cannot be continued because a timeout occurred while waiting for the MMB aa to boot Check the System Event Log Window to refer to the error details Meaning The MMB aa startup monitoring has timed out because the MMB aa start up failed to respond in the initial diagnosis Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error E 00313 Maintenance cannot be continued because the MMB aa is in Failed status Check the System Event Log Window to refer to the error details Meaning The operation cannot continue because MMB aa had started in the Fail state Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown dow
155. evicelD 04x SubvendorID 04x Subsystem 04x on IOU_ dGbE Meaning RAID Card SAS topology error Corrective action Check if normal operation could be restored by each step 1 Remove the physical disk drive wait 30 seconds and install the disk drive 2 Replace the physical disk drive 3 Replace the backplane the expander module and data cable 4 f the problem persists please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C8A70D04 RAID Card Foreign configuration table overflow VendorlD 04x DevicelD 04x SubvendorlD 04x Subsystem 04x on IOU_ dGbE Meaning RAID Card Foreign configuration table overflow Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C8A70D05 VendorlD 04x DevicelD 04x SubvendorlD 04x Subsystem 04x on IOU_ dGbE RAID Card Partial foreign configuration imported Meaning RAID Card Partial foreign configuration imported Corrective action Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C8A70D06 VendorlD 04x DevicelD 04x SubvendorlD 04x Subsystem 04x on IOU_ dGbE RAID Card Adapter cache pinned for missing or offline logical drives Meaning Because one or more log
156. f the state of Power On Corrective action Power off this partition Severity Warning W_00576 Unable to execute s because the firmware is updating Meaning The specified operation cannot process due to under the firmware update Corrective action Wait for finish of firmware update Severity Warning E 00582 Maintenance cannot be continued because an internal error occurred while waiting for status update Please check the System Event Log Window to refer to the error details Meaning Internal problem occurred during the waiting process of status change Firmware Update can t operate Corrective action The completed window is displayed if OK button in the dialog is pushed Download the system event log and contact your sales representative or a field engineer Severity Error W_00583 Unable to execute Firmware Update Please check the machine status Meaning Firmware Update can t operate Please check the machine status Corrective action Online firmware update is not available because machine status is OS running Please check the OS status and try again Severity Warning W 00584 The Dynamic Reconfiguration Mode cannot be changed while the Partition is Extended Partitioning Mode Meaning Dynamic Reconfiguration Mode cannot be set to this partition because this partition is Extended Partitioning Mode Corrective action Please check the Extended Partitioning mode Please operate th
157. failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13137 Adapter error mpt turbo reply Invalid cb idx Meaning The cb idx value is invalid turbo reply Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13138 Adapter error mpt reply Invalid cb idx Meaning The cb idx value is invalid non turbo reply Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13140 Adapter error Skipping because it s not operational Meaning The adapter is not in the operational state Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 94 CA92344 0540 05 MMB Messages 13141 Adapter error Skipping because it s disabled Meaning The adapter is in the Disable state Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13142 Adapter error Skipping because SCSI Initiator mode is NOT enabled Meaning The IOC is not in initiator mode Corrective action The HBA must be replaced If the error keeps recurring contact your sa
158. g All of dump devices contain memory image The n th dump device will be overwritten Corrective action If there is unnecessary memory image on the device initialize the device WARNING The device DUMP DEVICE1 DUMP DEVICE2 DUMP DEVICES could not be used Searching another device Meaning All of dump devices cannot be used Searching another device Corrective action Investigate the cause of problem and restore dump device THHEHHHHHHHHHHHHHHHHHHHHHES xx x Meaning Memory dumping is in progress xx x done Corrective action Wait for completion Dumping Complete Waiting for reboot Meaning Memory dumping is finished Corrective action Reboot system if needed 209 CA92344 0540 05 Appendix A Replacement component list Appendix A Replacement component list TABLE A 1 Replacement component list 1 Unit Source Replacement component Replacement component TypeB TypeA First item Second item SB 0 3 PCH SB 0 3 SB4 0 3 SB 0 3 PCH ESI SB 0 3 SB 0 3 CPU 0 SB 0 3 PCH PCle SB 0 3 SB 0 3 RAID Card SB 0 3 RAID Card RAID Card RAID Card SB 0 3 SB 0 3 BMC NIC SB 0 3 SB 0 3 SB 0 3 PCle SW 0 0 SB 0 3 SB 0 3 SB 0 3 PCle SW 0 8 SB 0 3 SB 0 3 IOU 1 SB 0 3 PCle SW 0 16 SB 0 3 SB 0 3 IOU 0 SB 0 3 PCle SW 1 0 SB 0 3 SB 0 3 SB 0 3 PCle SW 1 8 SB 0 3 SB 0 3 IOU 3 SB 0 3 PCle SW 1 16 SB 0 3 SB 0 3 IOU 2 IOU 0
159. guration Corrective action Check the mix status of the SB Severity Error W 00520 Unable to register the specified SB d as a Reserved SB due to abnormal SB composition Meaning The SB cannot be specified as a Reserved SB because there is an error in the configuration Corrective action Check the mix status of the SB Severity Warning 189 CA92344 0540 05 MMB Messages E 00521 Unable to register the specified Partition s as Mirror Mode enable because of abnormal SB composition Meaning Unable to set the Mirror Mode because of a problem in the SB configuration is notified if there is a problem in the SB in the partition Mirror Mode setting process Corrective action Check the mix status of the SB configuring the partition Severity Error W_00527 The MMB x s firmware is different version After Maintenance completion execute Unified Firmware Update Meaning The firmware version of MMB will be different from the version before the replacement After the maintenance work is completed execute the Unified Firmware Update Corrective action After completion of the maintenance execute Unified Firmware Update Severity Warning W_00529 Unable to execute Firmware Update because the chassis information could not be retrieved Meaning Unified Firmware Update cannot be performed since the value of the FRU cannot be acquired After completion of the maintenance work execute Unified Firmware Upd
160. has been completed successfully Meaning This message appears when the specified firmware has been updated successfully The firmware of aa has been successfully updated is notified Corrective action No action is necessary Severity Info W 00236 Failed to switch Location LED on but maintenance will still continue After Maintenance completion Check the System Event Log Window to refer to the error details Meaning Location LED lighting has failed There may be a fault but the process is continued since this does not affect the maintenance work Corrective action As there may be a fault in the relevant unit check the system event log after the maintenance work Severity Warning 170 CA92344 0540 05 MMB Messages 00237 The firmware update of aa has been completed successfully Firmware Version bb Meaning When this window appears after the specified firmware has been updated successfully aa firmware has been successfully updated is notified Corrective action This window is displayed again when the OK button of the dialog box is clicked Since the firmware update has been processed successfully click the Next button to continue the process Severity Info W_00237 The power status of one of the partitions is now Standby The selected Maintenance Operation Mode has become unavailable Please check that the power status of partitions is On in the Partition Power Control Window Then p
161. has to be incorporated in the specified partition Severity Error Unable to register the specified SB d as a Reserved SB due to abnormal SB composition Meaning Unable to register in the Reserved SB because there is an error in the SB configuration Corrective action Make the SB where the partition has been configured to be the same as the Reserved SB Severity Warning 141 CA92344 0540 05 MMB Messages Unable to register the specified Partition s as Mirror Mode enable because of abnormal SB composition Meaning Unable to set the Mirror Mode because there is a problem in the SB configuration is notified when there is a problem in the SB configuration in the partition Mirror Mode setting Corrective action Confirm the combination status of the SB which has to be incorporated in the specified partition Severity Error Error Specified file is NOT found Meaning specified file could not be found Corrective action Check whether there is any error in the file name or whether the file is stored in the specified path Severity Error Error Specified file is NOT MMB or Unified Firmware file Meaning Even if the file is an MMB Firmware File a file which is not a unified Firmware File has been specified Corrective action Check the specified file Severity Error Command Failed Code aa bb Meaning The update command has terminated abnormally aa Exception code bb Action code Correct
162. he cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error E 00303 Maintenance cannot be continued because chassis status could not be retrieved Check the System Event Log Window to refer to the error details Meaning The acquisition of the system chassis power status in Hot System Maintenance Warm System Maintenance has terminated abnormally Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error E 00304 Maintenance cannot be continued because FAN Speed Mode could not be set to high speed Please check System Event Log Window to refer to the error details Meaning The FAN high speed setting process executed in Hot System Maintenance Warm System Maintenance has terminated abnormally Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error E 00305 Maintenance cannot be continued because PCI Box FAN Speed Mode could not be set to high speed Check the System Event Log Window to refer to the error details Meaning The PCI Box FAN high speed s
163. he operation after releasing the maintenance mode Corrective action Execute after releasing the maintenance mode Severity Info 00130 Maintenance operator s session has been taken over Meaning The maintenance operator privilege session has been taken over because the user who had set maintenance mode has logged out Corrective action No action is necessary Severity Info 00201 Please select a maintenance type Meaning No maintenance type has been selected Corrective action Select the maintenance type Severity Info 00202 Another user is currently performing maintenance Please release Maintenance Mode if you still want to proceed Meaning Another user is performing the maintenance Release the maintenance mode before proceeding with the operation Corrective action Release the maintenance mode before proceeding Severity Info 161 CA92344 0540 05 MMB Messages 00203 Please select a unit to perform maintenance on Meaning The unit is not selected Corrective action Select a unit Severity Info 00204 A unit not in maintenance has been selected Are you sure Meaning The selected item is outside the scope of maintenance range The message asks for proceeding with the process Corrective action A confirmation window appears when the user selects a unit which is not in the scope of maintenance and clicks the Status Clear button The status of the sel
164. he process was completed Corrective action No action is necessary Severity Info 00612 Group information editing was completed Meaning This is message that the process was completed Corrective action No action is necessary Severity Info 195 CA92344 0540 05 MMB Messages 00613 Group deletion was completed Meaning This is message that the process was completed Corrective action No action is necessary Severity Info W 00614 Invalid character is included in GroupName Meaning The GroupName includes forbidden character Corrective action Confirm naming rule of Group Name For the detail of making of the LDAP User Group refer to 1 4 4 2 LDAP User Group List window in the PRIMEQUEST 2000 series Operations Management Tool Reference CA92344 0539 Severity Warning W 00615 Groupname is too short Meaning Groupname is too short Corrective action Confirm naming rule of Group Name For the detail of making of the LDAP User Group refer to 1 4 4 2 LDAP User Group List window in the PRIMEQUEST 2000 series Operations Management Tool Reference CA92344 0539 Severity Warning W 00616 The duplicate LDAP Server was found Meaning LDAP Server was duplicated Corrective action Confirm setting of LDAP Severity Warning W 00617 LDAP cannot be enabled because special account is not made with CLI Meaning LDAP cannot be enabled because special account is not made
165. herwise electric shock injury or fire may result Newly installing or moving equipment Removing the front rear and side covers nstalling and removing built in options Connecting and disconnecting external interface cables Maintenance repair and periodic diagnosis and maintenance The List of important alert items table lists important alert items iii CA92344 0540 05 Overview of Messages List of important alert items This manual does not contain important alert items Warning labels Never remove the warning labels Warning label location the main cabinet top CA92344 0540 05 Overview of Messages HAZARDOUS VOLTAGE SERVICE ENGINEER ONLY TOUCH THE INSIDE LI LLELUS IEETL S LU t gl REREAD OT TT ELA TENSIONS DANGEREUSES SEUL UN ING NIEUR PEUT VERIFIER L INT RIEUR Warning label location the main cabinet left a CAUTION ATTENTION ba ii EEJ B LER d Karan SEE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THIS UNIT Li BPRARWERTPELAT pt Lu VOIR LE MANUEL D INSTRUCTIONS AVANT D INSTALLER CET UNITE Warning label location PCI Box p 3 CAUTION SRACART ONC OM RECABLARRLY SEE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THIS UNIT 7WERCCIEAU 5 met n aee hog CAUTION ATTENTION RIVLSRMESATSC amp ELECTROSTATIC SENSITIVE DEVICES RFRENCALAHP ane CIRCUITS SENSIBLES A L ELECTRICIT STATIQUE suus PEE CAUTION Une a sur erent onc T IB mr AZARDOUS VO
166. hotadd partition command Meaning MMB internal error occurred in DR processing Corrective action Download SEL and contact your sales representative or a field engineer Failed to execute DR operation Partition is stopped Meaning Power of the partition is turn off or the partition is reset in DR processing Corrective action No action is necessary The specified SB x IOU x is not present Meaning The specified SB IOU is not present in system Corrective action Please confirm SB IOU number and configuration of the partition Mount SB IOU in the slot of the specified SB IOU number 148 CA92344 0540 05 MMB Messages The specified Partition Z is no Home Meaning The obtaining information of Home SB of the specified partition is failed Corrective action Please try again If it fails contact your sales representative or a field engineer Unable to hot add SB due to SB revision mismatch Meaning Hot add SB cannot execute because the version of specified SB is invalid Corrective action Please confirm SB number Exchange the specified SB if the version of specified SB is different from the version of SB in the specified partition DR sequence timeout added SB power on failure Meaning Timeout of DR sequence occurred because power of added SB cannot turn on Corrective action Confirm SEL Exchange the failure component if a component is failure DR sequence timeout SB hot add OS failure Meaning Tim
167. ical drives disappeared the array controller s cash is maintained Corrective action Please confirm a present state of a logical drive Exchange physical disk drive that break down when it is critical and do the rebuild Please restore data from the repeated making do over again and the backup of the array composition at off line Severity Warning C8A70E00 BBU on RAID controller on battery Meaning The RAID card runs with the battery Corrective action Confirm the power supply to the RAID card Severity Warning 61 CA92344 0540 05 MMB Messages C8A70E01 BBU on RAID controller battery low Meaning The battery voltage reduction was detected Corrective action Confirm whether the cable is correctly connected Still when the problem continues it is necessary to exchange the FBU Severity Warning C8A70E02 BBU on RAID controller failed Meaning The battery breakdown was detected Corrective action The calibration of the FBU is executed It takes about one day to the completion of this process Confirm whether the cable is correctly connected when the problem continues When the problem is not canceled it is necessary to exchange the FBU Severity Warning C8A70E03 BBU on RAID controller temperature problem detected Meaning Temperature problem of FBU on RAID controller detected Corrective action 1 Please confirm the temperature of ambient is in a regulated value 2 When the problem is
168. ime Displayed when resetting of Active MMB has started Corrective action Not required Severity Info 00468 Are you sure want to clear the SEL Meaning The message asks whether to execute the process of clearing the system event log Corrective action Not required Severity Info 00469 The settings for the Virtual IP Address are changed All existing network connections about this settings will be lost You will need to login again If you want to continue please click OK button If not click Cancel button Are you sure Meaning When the Virtual IP is set the currently connected network connections will be disconnected After setting it is necessary to again login to the Web UI Corrective action Not required Severity Info 00470 The new settings for the IP Address of the Active MMB are specified All existing network connections about this settings will be lost If you want to access the MMB again click the Network Interface menu after clicking OK button Are you sure Meaning On setting the physical IP address of Active MMB the network connection is temporarily lost After setting click the Network interface again in the menu Corrective action Not required Severity Info W 00471 Invalid hostname was found Meaning The host name is invalid Corrective action Check the host name Severity Warning 184 CA92344 0540 05 MMB Messages W_00472 Unable to get the reserv
169. ing 12078 Adapter error bigger then rsp ring Meaning The index of the response ring on the port side is larger in value than the ring size Corrective action Driver firmware or hardware has a fault Replace the adapter Severity Warning 85 CA92344 0540 05 MMB Messages 12080 Adapter error Unknown IOCB command Data Meaning An unknown IOCB command was detected for a function for fast path processing with IOCB of a FCP ring as the target Corrective action A driver or firmware has a fault If the problem persists replace the adapter Severity Warning 12081 Adapter error Unknown IOCB command Data Meaning An unknown IOCB command was detected for a function for slow path processing with IOCB of a non FCP ring for example ELS ring as the target Corrective action A driver or firmware has a fault If the problem persists replace the adapter Severity Warning 12089 Adapter error Adapter failed to mbxcmd CONFIG HBQ Meaning Adapter initialization failure The CONFIG_HBQ mailbox command failed Corrective action A card or the card firmware has a fault Contact your sales representative or a field engineer Severity Warning 12091 Adapter error Adapter failed to set maximum DMA length mbxStatus Meaning Adapter initialization failure Corrective action No action is necessary Severity Warning Remark This error is not detected after SVAS SVAgent V7 10 16 This er
170. ing PCle lt x gt is already available Corrective action PCle lt x gt that tried to be added is already available Please confirm whether the slot number is wrong dr util ERR 282 IOU xs device is already available Meaning IOU x is already available Corrective action IOU x gt that tried to be added is already available Please confirm whether the slot number is wrong dr util ERR d PCle lt x gt device is not available d 283 284 Meaning PCle lt x gt is not available Corrective action There s no PCle device on the specified slot Please confirm whether the slot number is wrong or insert PCIe device on the specified slot dr util ERR d IOU x device is not available d 285 286 Meaning IOU x is not available Corrective action The specified IOU is not assigned to Partition Please confirm whether the slot number is wrong or assign IOU to Partition dr util ERR 287 cpu x device is already disabled Meaning CPU lt x gt is already unavailable Corrective action CPU lt xs gt is already unavailable No action is necessary dr util ERR 287 memory lt x gt device is already disabled Meaning memory lt x gt is already unavailable Corrective action memory lt x gt is already unavailable No action is necessary dr util ERR 288 PCle lt x gt device is already disabled Meaning PCle x is already unavailable Corrective action PCle lt x gt that tri
171. ing The path was isolated Corrective action Check the device indicated by Unit and Source in SEL of MMB Severity Error m PCle SSD Windows related 28716 Adapter error Internal error Meaning An internal error occurred Corrective action If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28717 Adapter error Incompatible PCI slot bandwidth Meaning The PCI slot bandwidth is incompatible Corrective action If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28718 Adapter error Write performance reduced Meaning Write performance decreased Corrective action If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 117 CA92344 0540 05 MMB Messages 28719 Adapter error Write operations disabled Meaning Write operations are disabled Corrective action If the error recurs collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28720 Adapter error Temperature close to error threshold Meaning The temperature is reaching the error threshold Corrective action
172. ing The set partition command has terminated abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error Failed to execute show partition command Meaning The show partition command has terminated abnormally Corrective action If another message is output see the message Try setting again If it fails contact your sales representative or a field engineer Severity Error The specified gateway address is invalid Meaning An invalid gateway address has been specified Corrective action Check the command parameter Severity Warning 132 CA92344 0540 05 MMB Messages The specified smtp address is invalid Meaning An invalid SMTP address has been specified Corrective action Check the command parameter Severity Warning The specified partition name is invalid Meaning An invalid partition name has been specified Corrective action Check the command parameter Severity Warning Partition x is not defined Meaning As Partition x is an undefined partition the CLI command does not perform the settings Corrective action Check if the partition is specified correctly Also confirm the partition configuration Severity Warning Succeed to set partition name command Meaning The set partition name command has terminated normally Corrective action No action is
173. ion No action is necessary Severity Info B02003FF Operating system graceful shutdown Meaning The OS has shut down Corrective action No action is necessary Severity Info B02004FF Soft shutdown initiated by platform event filtering PEF Meaning The OS has shut down by PEF Corrective action No action is necessary Severity Info B02005FF Agent Not Responding Meaning The agent does not respond Corrective action No action is necessary Severity Info 33 CA92344 0540 05 MMB Messages mWatchdog related BMC B0236FFF Watchdog Action Timer Interrupt Meaning Watchdog timer has timed out For the operation to be performed after expiration of the Watchdog timer the operation specified by Automatic Server Restart ASR Control is prioritized if the retry count specified by ASR Control has been exceeded Corrective action Replace all CPUs on the System Board Severity Error B0236FFF Watchdog Action Hardware watchdog Meaning Watchdog timer has timed out For the operation to be performed after the expiration of the Watchdog timer the operation specified by the ASR Automatic Server Restart Control would be prioritized if the number of retries specified by ASR Control has been exceeded Corrective action Download the system event log and contact your sales representative or a field engineer Severity Error B0236FFF Watchdog Action Power Cycle Meaning
174. ion mpt_dead_ioc failed in driver internal processing Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13213 Adapter error Running mpt_dead_ioc thread success Meaning Hardware failure Adapter deletion mpt_dead_ioc was successful in driver internal processing Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13216 Adapter error mpt_config timed out Meaning A config request to the adapter timed out during adapter reset processing Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning mPCle SSD Linux related 13900 Adapter error SMP Firmware not in Run mode Meaning The SMP Firmware was not in Run mode during driver loading Corrective action Collect the data for investigation dump or fjsnap Ask your sales representative or a field engineer to perform an investigation Severity Warning 13901 Adapter error failed to load midprom data Meaning Loading of midprom information occurred during driver loading Corrective action Collect the data for investigation dump or fjsnap Ask your sales representative or a field engineer to perform an investigation Severity Warning 13902 Adapter er
175. ion n because you have not authority to operate this partition Meaning The Partition Operator has issued a power On instruction for a partition which is not within the scope of management Power On is suppressed for Partition n This error message is displayed only for partition Operators Corrective action Check the processing target partition Severity Warning Unable to power on the partition s because the partition which does not have authority to you is included in the specified parameter Meaning The Partition Operator has issued a power On instruction for a partition which is not within the scope of management Power On is suppressed for the specified partition This error message is displayed only for partition Operators Corrective action Check the command parameter and the processing target partition Severity Warning Specified host does NOT respond Meaning There is no communication with the host Corrective action Check the specified URL with the Firmware Update Retry if there is no problem Severity Warning The specified MMB x is NOT present Meaning As the specified MMB is not mounted it cannot be specified as an Active MMB Corrective action Check the MMB mounting status Severity Warning 129 CA92344 0540 05 MMB Messages The specified MMB x is disabled Meaning As the specified MMB has been disabled it cannot be specified as an Active MMB Corrective action Enable
176. is Information access failure Meaning The cabinet information was corrupted Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Warning 15070107 MMB Communication Lost LAN Meaning LAN communication between MMBs was disconnected Corrective action An MMB must be replaced If normal operation could not be restored the other MMB must be replaced Severity Warning Remarks This is basically an error on the Standby side 15070108 MMB Communication Lost COM Meaning COM port communication between MMBs was disconnected Corrective action An MMB must be replaced If the operation could not be restored the other MMB must be replaced Severity Warning 15070119 MMB Watchdog Timer expired Meaning The Watchdog Timer has timed out Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Warning 1507011A Heartbeat Lost Meaning Another system MMB has failed Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Warning 11 CA92344 0540 05 MMB Messages 1507011B MMB Firmware error Meaning The firmware may be damaged Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Warning 15070175 Correctable error logging limit reached Meaning Correctable errors ha
177. ise Critical was detected Corrective action If the Inlet Temp is normal and CPU Temp is abnormal please check the state of the filter the heat sink and installation environment When the improvement is not seen replace the CPU Severity Error B0010592 CPU 1 Temp Temperature high critical C Meaning A temperature rise Critical was detected Corrective action If the Inlet Temp is normal and CPU Temp is abnormal please check the state of the filter the heat sink and installation environment When the improvement is not seen replace the CPU Severity Error B0018571 CPUZO Temp Temperature OK Meaning The temperature is now normal Corrective action No action is necessary Severity Info 27 CA92344 0540 05 MMB Messages B0018572 CPU 1 Temp Temperature OK Meaning The temperature is now normal Corrective action No action is necessary Severity Info B0018591 CPU 0 Temp Temperature high warning C Meaning A temperature rise Warning was detected Corrective action If the Inlet Temp is normal and CPU Temp is abnormal please check the state of the filter the heat sink and installation environment Severity Warning B0018592 CPU 1 Temp Temperature high warning C Meaning A temperature rise Warning was detected Corrective action If the Inlet Temp is normal and CPU Temp is abnormal please check the state of the filter the heat sink and
178. isk or Boot Device because OS loader is abnormal behavior If there is not any problem download the system event log and contact your sales representative or a field engineer Severity Error 34 CA92344 0540 05 MMB Messages B0236F01 BIOS FRB2 Action Hard Reset Meaning Watchdog timer has timed out For the operation to be performed after expiration of the Watchdog timer the operation specified by Automatic Server Restart ASR Control is prioritized if the retry count specified by ASR Control has been exceeded Corrective action Download the system event log and contact your sales representative or a field engineer Severity Error B0236F02 BIOS POST Watchdog Action Hard Reset Meaning Watchdog timer has timed out For the operation to be performed after expiration of the Watchdog timer the operation specified by Automatic Server Restart ASR Control is prioritized if the retry count specified by ASR Control has been exceeded Corrective action Download the system event log and contact your sales representative or a field engineer Severity Error B0236F03 BOOT Watchdog Action Meaning Watchdog timer has timed out For the operation to be performed after expiration of the Watchdog timer the operation specified by Automatic Server Restart ASR Control is prioritized if the retry count specified by ASR Control has been exceeded Corrective action Please check the setting of Boot Disk or
179. isplayed To keep the maintenance mode click the Cancel button The current window will appear The browser returns to the first window when the Previous button is clicked Severity Info 00233 One or more partitions are powered on Are you sure you want to release Maintenance Mode Meaning When an attempt is made to release the maintenance mode and the OK button is clicked while there is a powered on partition under maintenance a confirmation message The partition power is on Do you want to cancel the maintenance mode is displayed Corrective action The first window is displayed when the OK button is clicked while canceling the maintenance mode This window appears when the Cancel button is clicked to keep the maintenance mode When the Previous button is clicked the browser returns to the first window Severity Info W 00233 Unable to select a unit with all partition powered on Please check that you selected the right type of unit then check that the power status of partitions is Standby in the Partition Power Control Window Then please try again Meaning There is no unit that can be maintained because the partition power is on Corrective action Check if the correct unit has been selected or whether the status of the partition power is Standby in the Partition Power Control window After confirmation start the maintenance work again Severity Warning 00236 The aa firmware update
180. ity is Info the following messages are sent via REMCS or SNMP trap The following table shows if messages have been sent TABLE 2 1 Messages sent even by Info Event ID Message Sent via REMCS Sent via SNMP trap CO6FOOFF Power Off Not sent Sent CO6F01FF Power On In Progress Not sent Sent CO6F0201 Reset Not sent Sent CO6FO2FF Reset Not sent Sent CO6FO3FF EFI Not sent Sent CO6FO4FF Boot Not sent Sent CO6FO5FF OS Running Not sent Sent CO6FO6FF OS Shutdown Not sent Sent CO6FO7FF Panic Sent Sent CO6FO8FF Power Off In Progress Not sent Sent CO6FO9FF Fatal Not sent Sent CO6FOAFF Dumping Not sent Sent CO6FOBFF Halt Not sent Sent CO6FOCFF Stop Error Sent Sent CA92344 0540 05 MMB Messages 2 1 1 Tem perature sensor related messages Temperature Sensor related messages are listed below 010100FF Lower Non critical going low Assert 0C threshold 0C Meaning Low temperature warning has occurred Corrective action Check whether the monitored temperature has decreased as shown below in the environment of the server installed locations Window left open in cold weather Air conditioner temperature setting etc For PSU S and PSU P If the Inlet Temp is normal and PSU S or PSU P Temp is abnormal please replace PSU S or PSU P Severity Warning 010107FF Upper Non critical going high Assert 0C threshold o0C Meaning High temperature warning h
181. ive action If there is another message which has been output refer the message Try setting again If it fails contact your field engineer Severity Error Extracting an unified firmware file Meaning A unified Firmware File is extracted Corrective action None Severity Info The MMB firmware cannot be updated while any partitions are powered on Please try to update after the all partitions are powered off Meaning The MMB Firmware could not be updated since there are partitions that are powered on Corrective action Try updating after turning Off the power of all the partitions Severity Warning MMB d is NOT present Meaning MMB x has not been executed Corrective action Check the MMB execution status Severity Warning 142 CA92344 0540 05 MMB Messages Unable to execute Firmware Update due to resource lock Please retry after waiting a while Meaning The Firmware Update is locked Wait for some time and then retry Corrective action Some of the resource occupied processes are subject to exclusive control Please wait and retry after sometime Severity Info The DIMM does not satisfy requirements of the Mirror Mode If you register the specified SB s as a Reserved SB the Mirror Mode will be disabled when switching to specified SB Are you sure to continue Y N Meaning The DIMM does not meet the requirements of the Mirror Mode If the specified SB s is registered as a Reserve
182. ive or a field engineer Severity Error C8A10494 PCle SW Downstream Completion Timeout Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10495 PCle SW Downstream Completer Abort Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error 54 CA92344 0540 05 MMB Messages C8A10496 PCle SW Downstream Unexpected Completion Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10497 PCle SW Downstream Receiver Overflow Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10498 PCle SW Downstream Malformed TLP Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10499 PCle SW Downstream ECRC Error Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a
183. k Meaning An invalid DMA mask was detected during adapter installation Corrective action An HBA or a driver has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13176 Adapter error HardReset FAILED Meaning The hard reset of the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13177 Adapter error reset failed Meaning The adapter reset failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13181 Adapter error mpt fault reset work HardReset Meaning The result of resetting the adapter is output Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13182 Adapter error IOC is in FAULT state after reset Meaning After an adapter reset the adapter remains in the fault state Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13183 Adapter error pci enable device failed Meaning pci enable device PCI device initialization failed Corrective action The HBA must be replaced If the error keeps recurring contact
184. l ERR 402 Failed to add memory lt x gt with error lt y gt Meaning Add memory lt x gt with error number y is failed Corrective action The addition of memory lt x gt failed because of the error y Please gather the information for investigation by using opt FJSVdr util sbin dr report on the partition side and contact the technology of our company member dr util ERR 403 Failed to add MEM x total lt y gt Meaning Add memory x total y kB is failed Corrective action The addition of memory lt x gt of the total y gt kB failed Please gather the information for investigation by using opt FJSVar util sbin dr report on the partition side and contact the technology of our company member dr util ERR 404 Exited x with status y at z timing Abort SB hot add Meaning Collaboration program lt x gt exited with status y at lt z gt timing SB hot add was aborted lt z gt represents before or after Corrective action SB hot add was aborted because of the failure of collaboration program lt x gt Please review the output messages of collaboration program lt x gt dr util ERR 405 Failed to add SB lt x gt Meaning The addition of SB lt x gt terminated abnormally Corrective action The addition of SB lt x gt aborted Please confirm the error messages and do corrective action according to error 201 CA92344 0540 05 Dynamic Reconfiguration Messages dr util
185. lease try again Meaning When the Next button was clicked after selecting Hot Partition Maintenance check the partition status and try again as the power status of the target partition has been changed by a user operation Corrective action This window is displayed again when the OK button is clicked Check the power status of the partition in the Partition Power Control window If the status is Standby ask the system administrator to power on the partition After confirmation perform the maintenance work again Severity Warning 00238 There is no error information Meaning The message notifies that error information of the unit was collected but no error was detected Corrective action No action is necessary Severity Info W 00238 Specified file is not a firmware file Please select a valid firmware file Meaning The file specified for the firmware update process is not a firmware file Corrective action This window is displayed again when the OK button is clicked Specify the correct firmware file Severity Warning W 00239 Specified file is not a aa firmware file Please select a valid aa firmware file Meaning A file which is not a aa firmware file has been specified in the firmware update Corrective action This window is displayed again when the OK button is clicked Specify the correct firmware file Severity Warning W 00240 Specified file does not correspond to this
186. les representative or a field engineer Severity Warning 13146 Adapter error operation failed Meaning The SAS persistent operation failed Corrective action Collect the data for investigation dump or fjsnap Contact your sales representative or a field engineer Replace the adapter Severity Warning 13147 Adapter error Controller disabled Meaning The controller is not in the active state Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13153 Adapter error readl detects master abort Meaning A master abort occurred in PCI read The operation ran out of retries Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13161 Adapter error IOC Not operational Meaning The adapter is not in the operational state Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13163 Adapter error ioc state DDOORBELL ACTIVE Meaning The adapter has the DOORBELL ACTIVE flag turned on Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 95 CA92344 0540 05 MMB Messages 13173 Adapter error no suitable DMA mas
187. lid MAC address Corrective action Replace the adapter Severity Error 21861 Adapter error The fan on the network adapter has failed Meaning An adapter failure occurred Corrective action Turn off the computer and replace the network adapter Severity Error 21863 Adapter error overheated Meaning The network adapter has stopped because of overheating Corrective action Perform a restart If the problem persists turn off the computer and replace the network adapter Severity Error 21902 Adapter error EEPROM error Meaning An error may have occurred in the EEPROM of the adapter Corrective action Replace the adapter Severity Error 114 CA92344 0540 05 MMB Messages 21910 Adapter error The fan on the network adapter has failed Meaning An adapter failure occurred Corrective action Turn off the computer and replace the network adapter Severity Error 21912 Adapter error MAC address is invalid Meaning The network adapter has an invalid MAC address Corrective action Replace the adapter Severity Error 21913 Adapter error overheated Meaning The network adapter has stopped because of overheating Corrective action Perform a restart If the problem persists turn off the computer and replace the network adapter Severity Error 22000 Adapter error Meaning A driver firmware or HBA error occurred Corrective action Update or reinsta
188. list The following section describes how to display the System Event Log window and the display items and how to download the log data Displaying the System Event Log window 1 Select in the order of System System Event Log System Event Log window appears displaying the stored system event log FIGURE 1 2 System Event Log window shows an example of the System Event Log window 1 CA92344 0540 05 Overview of Messages FIGURE 1 2 System Event Log window gt System gt System Event Log m 2013 12 11 nfo 1173940 2013 12 11 17 38 53 2013 12 11 17 38 52 2013 12 11 17 0722 2013 12 11 17 05 35 2013 12 11 17 05 04 2013 12 11 17 04 42 2013 12 11 17 03 55 2013 12 11 a u L C C L C C C L C Partition User Administration Network Configuration Maintenance System Event Log Partition 0 P 0 Sys Status P 0 Sys Status P 0 Sys Status P 0 Sys Status Partition 0 P 0 Sys Status CO6FOOFF COGFOSFF COGF04FF COGFO2FF COGFO1FF Power Off Power Off In Progress Power On In Progress Logout Partition 0 P20 Sys Status COGFOOFF Power Of Partition 0 Partition 0 P 0 Sys Status P 0 Sys Status COGFOSFF MAETATT Power Off In Progress D System Event Log window display items For details on the display items of the System Event Log window see 1 2 2 System Eve
189. ll the created SSH Server Key click the OK button Corrective action Not required Severity Info W 00454 aa is duplicated Meaning aa is already registered Displayed when there is duplication of the user name Corrective action Check the Username Severity Warning W 00455 Both passwords are mismatched Please try again Meaning The passwords do not match Re enter the passwords Corrective action Enter the passwords again Severity Warning W 00456 Invalid E Mail address format Meaning The e mail address format is incorrect Corrective action Check the e mail address Severity Warning W 00457 Invalid SMTP server address Meaning The SMTP server format is incorrect Corrective action Check the SMTP server name Severity Warning 00458 Please check a Subject Meaning Check the Subject Corrective action Check the Subject Severity Info 182 CA92344 0540 05 MMB Messages W_00459 Alarm E Mail is disabled Meaning The Test Mail cannot be sent since the Alarm E Mail setting is Disabled Corrective action Enable the Alarm E Mail setting Severity Warning E 00460 Unable to register the specified SB s as a Reserved SB due to CPU composition abnormal Meaning Unable to register the SB as a Reserved SB because the CPU configuration is abnormal Corrective action Check the status of the CPU mounted on the SB Severity Error E 00461 Una
190. ll the driver If the problem persists replace the adapter For the error codes see the Emulex storport Miniport Driver manual Severity Error 22014 Adapter error network device detected a hardware Meaning A hardware error occurred Corrective action Replace the adapter Severity Warning 22126 Adapter error Uncorrectable error detected Meaning An Uncorrectable error occurred Corrective action Check whether the driver is latest version If it is latest version replace the adapter Severity Warning 22127 Adapter error Hardware initialization failed failing Meaning Driver loading failed because of a hardware initialization failure Corrective action Replace the adapter Severity Warning 115 CA92344 0540 05 MMB Messages 22132 Adapter error Failed to map Base Address Register failing driver load Meaning Mapping of Base Address Register is failed and loading of driver is failed Corrective action Check whether the driver is latest version If it is latest version replace the adapter Severity Warning 22133 Adapter error Hardware initialization has failed Meaning Initialization of hardware failed Corrective action Replace the adapter Severity Warning m SAS Windows related 23200 Adapter error Controller Error occurred Meaning The SAS driver detected an error Corrective action A driver adapter or HDD error may have occurred Contact your s
191. log replace the unit according Replacement Component Type B in the TABLE A 1 Replacement component list 1 Severity Error BC5030B0 Legacy PCI Target Abort Bus Device 0x Function 0x Meaning Error has been detected in the PCI or PCI express data Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type B in the TABLE A 1 Replacement component list 1 Severity Error BC5030C0 Legacy PCI Received Target Abort Bus Device 0x Function 0x Meaning Error has been detected in the PCI or PCI express data Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC5030D0 Legacy PCI Received Master Abort Bus Device 0x Function Ox Meaning Error has been detected in the PCI or PCI express address Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC5030E0 Legacy PCI PERR Bus Device 0x Function Ox Meaning An internal error was detected in the PCI or PCI express Device Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Ty
192. ment eeeeeseeeeeeee teens 198 3 2 Messages concerning trouble that occurs in DR command eseeeeeenene entente nennen nnns 198 3 3 Messages concerning trouble that occurs in the OS kernel sese tette tentent 201 3 4 Messages concerning trouble that occurs outside of DR command other than OS kernel sss 204 3 5 Messages concerning DR command progress eee essent netten nennen tenentem nennen tenete entente 205 CHAPTER 4 sadump Messages vente e ert eee tec Ed ant d Etc te ted Cath 208 4 1 sadump Messadge lISE itt ei ein np RR ug eu ui eni eene 208 Appendix A Replacement component list eee eite ten este se netten tente ttn tnb sette bete te teta tote sent totes satt she tnn sesenta nnns 210 xii CA92344 0540 05 Overview of Messages Figures FIGURE 1 31 Information area acetanilide 1 FIGURE 1 2 System Event OG WNO e e icti eger Pi ERR ORE CHR eee ee rg ee biete 2 xiii CA92344 0540 05 Overview of Messages Tables TABLE 2 1 Messages sent even by Info entente tete neni sete e tee Te AE ee ceu tea ce eb seniors 3 TABLE A1 Replacement component ISt tritt trie rper tert tre ptr riget Lt Porc pend 210 TABLE A 2 Replacement component list 2 eese e eseese sense sese tentn tnnt tentent tentent these tende tantes se te taedet 211 xiv CA9234
193. mode and then the data will NOT be written to the device anymore Corrective action Replace the PCle SSD card to the new one which is already purchased Severity Info 19055 Adapter error Reliability degraded 1 6TB card Meaning The reliability is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 109 CA92344 0540 05 MMB Messages 19056 Adapter error Temperature above warning threshold 1 6TB card Meaning Temperature has exceeded the upper warning threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 19057 Adapter error Adapter removed 1 6TB card Meaning Adapter is removed Corrective action Replace the PCle SSD card Severity Warning 19100 Adapter error Internal error 2 0TB card Meaning Internal error has occurred Corrective action Replace the PCle SSD card Severity Warning 19101 Adapter error Write performance reduced 2 0TB card Meaning Write performance is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19102 Adapter error Write operations disabled 2 0TB card Meaning Write oper
194. n after you replace the HBA replace the device e g PCI Box connected to the HBA Severity Warning 13123 Adapter error detects pci parity error Meaning A parity error occurred during reading of the PCI status register Corrective action The HBA must be replaced If the problem persists even after you replace the HBA replace the device e g PCI Box connected to the HBA Severity Warning 93 CA92344 0540 05 MMB Messages 13124 Adapter error detects pci parity error Meaning A parity error occurred during reading of the PCI status register The operation ran out of retries Corrective action The HBA must be replaced If the problem persists even after you replace the HBA replace the device e g PCI Box connected to the HBA Severity Warning 13125 Adapter error detects pci parity error Meaning A parity error was detected during a DMA transfer Corrective action The HBA must be replaced If the problem persists even after you replace the HBA replace the device e g PCI Box connected to the HBA Severity Warning 13129 Adapter error Sending lOCInit failed Meaning The MPT request reply wait process for the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13130 Adapter error Sending PortEnable failed Meaning A PortEnable request sent to the adapter
195. n the primary side failed Corrective action Confirm that the communication path to the monitoring target has no problems Severity Error 17005 Network error Secondary polling failed Meaning Transmission path monitoring on the secondary side failed Corrective action Confirm that the communication path to the monitoring target has no problems Severity Error 105 CA92344 0540 05 MMB Messages 17006 Network error PrimaryHUB to SecondaryHUB polling failed Meaning HUB to HUB monitoring on the primary side failed Corrective action Confirm that the communication path to the monitoring target has no problems Severity Error 17007 Network error SecondaryHUB to PrimaryHUB polling failed Meaning HUB to HUB monitoring on the secondary side failed Corrective action Confirm that the communication path to the monitoring target has no problems Severity Error alB Linux related 18013 Failed to init command interface Meaning Initialization command failed Corrective action Replace IB HCA card Severity Warning 18018 Failed to allocate driver access region Meaning An error occurred during allocation of driver access region Corrective action Replace IB HCA card Severity Warning 18021 Couldn t save HCA PCI header Meaning An error occurred during save of HCA PCI header Corrective action Replace IB HCA card Severity Warning 18026 Couldn t restore HC
196. nable to set Partition Name of Partition aa because this partition is under maintenance Meaning The Partition Name of partition aa cannot be changed since maintenance is in progress Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info W 00217 The unit powering on has been skipped because chassis power status is currently off After Maintenance completion Check the System Event Log Window to refer to the error details Meaning The power of the unit cannot be turned on because the system cabinet power is off Corrective action The power on process was skipped however continue the operation Check the system event log after the completion of the maintenance work Severity Warning 166 CA92344 0540 05 MMB Messages 00218 PRIMEQUEST2800B2 2800B Unable to add SB IOU to Partition aa because this partition is under maintenance Meaning SB IOB cannot be added to partition aa because the partition is under maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info PRIMEQUEST2400E2 2800E2 2400E 2800E Unable to add SB IOU Extended Partitioning to Partition aa because this partition is under maintenance Meaning SB IOU Extended Partitioning cannot be added to partition aa because the partition is under maintenance Corrective action Wait until the maintenance work is completed
197. nd system environment as well Severity Warning 19007 Adapter error Adapter removed 800GB card Meaning Adapter is removed Corrective action Replace the PCle SSD card Severity Warning 108 CA92344 0540 05 MMB Messages 19050 Adapter error Internal error 1 6TB card Meaning Internal error has occurred Corrective action Replace the PCle SSD card Severity Warning 19051 Adapter error Write performance reduced 1 6TB card Meaning Write performance is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19052 Adapter error Write operations disabled 1 6TB card Meaning Write operations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 19053 Adapter error Temperature above error threshold 1 6TB card Meaning Temperature has exceeded the upper error threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 19054 Adapter error Memory is close to wearing out 1 6TB card Meaning The product lifetime end for write operation will come soon If the device is still used it will be switched to the Read Only
198. ng Error was detected in the communication with the BMC during the Private LAN monitoring Corrective action The system board must be replaced If the error persists the active MMB must be replaced Severity Error 286F04FF Sensor failure Meaning The temperature sensor has failed Corrective action For OPL Inlet Temp the target OPL must be replaced For PCleSW 0 1 Temp of IOU 0 3 the target IOU 0 3 must be replaced For Inlet Temp of PCI Boxst 0 1 the target PCI_Box 0 1 must be replaced For PCleSW 0 1 Temp of PCI Boxst 0 1 the target PCI Boxst 0 1 must be replaced Severity Error 2 1 11 FRU related The FRU related messages are listed below 2B6F0200 Hardware is incompatible Meaning An unsupported board has been mounted Corrective action Replace with a system compatible board Severity Error 2C6FOOFF FRU Not Installed Meaning The component is not mounted Corrective action No action is necessary Severity Info 25 CA92344 0540 05 MMB Messages 2C6F01FF FRU Inactive Meaning The component has stopped operating Corrective action No action is necessary Severity Info 2C6F02FF FRU Activation Requested Meaning Addition of the component has been requested Corrective action No action is necessary Severity Info 2C6F0705 FRU Comm Lost Meaning The fuse has blown Corrective action Target board must be replaced Severity
199. ng SB hot add was detected This indicates that OS detected SB hotadd dr util INFO 801 Added SB x Node lt y gt Meaning SB x Node lt y gt was added This indicates that OS adds SB lt x gt and Node lt y gt dr util INFO 802 Add CPU x total lt y gt Meaning CPU x total lt y gt will be added This indicates that OS will add CPU lt xs total y of CPUs dr util INFO 803 Added CPU x total lt y gt Meaning CPU lt x gt total lt y gt was added This indicates that OS added CPU lt xs total lt y gt of CPUs dr util INFO 804 Add MEM x total lt y gt Meaning Memory lt x gt total lt y gt kB will be added This indicates that OS will add memory lt x gt total lt y gt kB dr util INFO 805 Added MEM x total lt y gt Meaning Memory lt x gt total y kB was added This indicates that OS added memory lt x gt total y kB 205 CA92344 0540 05 Dynamic Reconfiguration Messages dr util INFO d Execute lt x gt user programs at lt y gt timing ed 806 807 Meaning lt x gt of collaboration programs will be executed at lt z gt timing lt z gt represents before or after dr util INFO 808 Executed user programs at x timing Meaning Collaboration programs executed at x timing x represents before or after dr util INFO 809 Added SB lt x gt Meaning The addition of SB lt x gt exited This indicates success
200. ng enter N Severity Info Unable to register the specified Partition d as Mirror Mode enable because the CPU mismatch between SBs Meaning Unable to set the Mirror Mode for Partition d as the CPUs mounted between the SBs do not match Corrective action Check the placement of the CPUs mounted on the SB and the combination status Severity Error Unable to register the specified Partition d as Mirror Mode enable because the DIMM does not satisfy requirements of Mirror Mode Meaning Unable to set the Mirror Mode for the specified partition since the DIMM does not meet the requirements of the Mirror Mode Corrective action Check the status of the DIMM that is mounted on the SB Severity Error 140 CA92344 0540 05 MMB Messages Unable to register the specified Partition d as Mirror Mode enable because the unsupported CPU configuration Meaning Unable to set the Mirror Mode for the Partition d since the CPU does not meet the mounting criteria Corrective action Check the placement of the CPUs mounted on the SB and the combination status Severity Error Unable to register the specified Partition d as Mirror Mode enable because of abnormal CPU composition Meaning Unable to set the Mirror Mode for Partition d as there is a problem in the CPU configuration Corrective action Check the CPU configuration of the SB in which the partition has been configured Severity Error Unable to regi
201. nit mbxCmd READ REV Meaning Initialization of the adapter failed Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12033 Adapter error Adapter failed to init mbxCmd READ REV detected outdated firmware Meaning Initialization of the adapter failed The HBA firmware revision could not be identified during initialization Corrective action Hardware or firmware has a fault Update the firmware If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12034 Adapter error Adapter failed to init mbxCmd CONFIG PORT Meaning Initialization of the adapter failed Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12035 Adapter error Adapter failed to init mbxCmd CFG RING Meaning Initialization of the adapter failed Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12037 Adapter error Adapter failed init mbxCmd READ SPARM Meaning Initialization of the adapter failed Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 84 CA
202. nload the system event log and contact your sales representative or a field engineer Severity Error E 00314 Maintenance cannot be continued because the MMB aa is in Degraded status Check the System Event Log Window to refer to the error details Meaning The operation cannot continue because MMB aa had started in Degraded Fail state Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for any errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error 174 CA92344 0540 05 MMB Messages E 00315 Maintenance cannot be continued because the MMB aa is in Warning status Check the System Event Log Window to refer to the error details Meaning The Operation cannot continue because MMB aa had started in the Warning state Corrective action The completion window appears when OK in the dialog box is clicked Check the system event log for errors If the cause is unknown download the system event log and contact your sales representative or a field engineer Severity Error W 00401 Username is too short Meaning User name is too short Corrective action Enter a user name with eight or more characters Severity Warning W 00402 Password is too short Meaning Password is too short Corrective action Enter a password with eight or more characters
203. nt Log window in the PRIMEQUEST 2000 series Operations Management Tool Reference CA92344 0539 Downloading the data Natail Save the system event log as it is important information for investigation It is important material when contacting your sales representative or a field engineer To download it click the Download button CA92344 0540 05 MMB Messages 2 1 CHAPTER 2 MMB Messages This chapter lists MMB messages by type For details on how to open an MMB window see 1 7 Basic Operations in the Web UI Window in the PRIMEQUEST 2000 Series User Interface Operating Instructions CA92344 0538EN MMB Message list This chapter describes the messages of the system even log which is displayed in the MMB Web UI The messages are arranged in the ascending order of the Event ID represents the Wild card character The following Severity items indicate the severity of messages Error Serious system problem Warning Event which is not necessarily serious but will be a potential problem in future Info Notification event Remarks Even in a message that normally displays Info High Severity would be displayed if the severity is high in the same unit Example of 2C6F02FF If an FRU Communication Lost Error has already occurred in the FRU Sensor Error is displayed instead of the normally displayed Info Error and Warning messages are sent via REMCS Mail or SNMP trap Note that even if the sever
204. nted on the Reserved SB are the same Severity Warning No more User addition Meaning Unable to add a user beyond this as the maximum number of registered users has been exceeded Corrective action Add the registration after deleting necessary users Severity Error No more Community addition Meaning The Community cannot be added beyond this as the maximum number of registered Community exceeded Corrective action Add the registration after deleting unnecessary Communities Severity Error The specified SB aa cannot be registered as a Reserved SB Meaning The specified SB aa cannot be registered as a Reserved SB Corrective action Try setting again If it fails contact your field engineer Severity Error Unable to set non redundant operation due to in dual power feed mode Meaning Unable to set the PSU Redundant Mode to Non redundant when the Power Feed Mod is Dual Corrective action Change the Power Feed Mode to Single when setting to Non Redundant Severity Info Unable to add the specified SB to the partition due to DIMM does not satisfy requirements of Mirror Mode Meaning Unable to add the specified SB since the DIMM does not meet the Mirror Mode requirements Corrective action Check the status of the DIMM that is mounted on the SB Severity Error 139 CA92344 0540 05 MMB Messages Unable to power on the Partition d due to DIMM does not satisfy requirements of Mirror
205. ntered the Link Up state Corrective action No action is necessary Severity Info 19 CA92344 0540 05 MMB Messages 2 1 6 28070812 User Port 0 halted Meaning User Port 0 of the MMB has entered the Link Down state Corrective action Check for an errors in the User Port network Severity Info 28070813 User Port 1 halted Meaning User Port 1 of the MMB has entered the Link Down state Corrective action Check for an errors in the User Port network Severity Info SB Memory Scale up Board IOU DU MMB OPL related The SB Memory Scale up Board IOU DU MMB or OPL related messages are listed below 150700FF Transition to OK Meaning The status is normal Corrective action No action is necessary Severity Info 150701FF Transition to Non critical from OK Meaning The status has changed from normal to warning Corrective action The target unit must be replaced Refer the message that is output at the same time and replace the unit Severity Warning 150702FF Transition to Critical from less severe Meaning The status has become abnormal Corrective action The target unit must be replaced Refer the message that was output at the same time and replace the unit Severity Error 150703FF Transition to Non recoverable from less severe Meaning There has been a transition to an abnormal state Corrective action The target unit must be replaced Refer the message that was
206. ode released Severity Info W_00545 Unable to change Extended Partition Configuration to Partition aa because this partition is powered on Meaning The configuration of Extended Partition cannot be changed since the partition is powered on Corrective action Change the Extended Partition configuration after turning off the partition power Severity Warning W 00550 Unable to select the option due to this Partition is not connected to VGA USB2 rKVMS Meaning Video Redirection cannot be selected since VGA USB2 rKVMS is not allocated to partition x Corrective action None Severity Warning W 00551 Unable to select the option due to Extended Partitioning mode of this Partition is enabled Meaning The option cannot be selected since the Extended Partitioning mode of Partitions x is set to Enable Corrective action None Severity Warning W 00552 The Extended Partitioning mode cannot be changed while the PPAR Partition is powered on Please try to change the Extended Partitioning mode after the PPAR Partition is powered off Meaning The mode cannot be changed since the PPAR Partition is powered on Corrective action Turn off the power of the PPAR Partition and then change the mode Severity Warning 191 CA92344 0540 05 MMB Messages W_00575 Unable to change partition configuration because this partition is powered on Meaning The partition cannot change the partition configuration because o
207. of SB hot add dr util INFO 820 Detected SB hot remove Meaning SB hot remove was detected This indicates that OS detected SB hotremove dr util INFO 821 Remove SB lt x gt Node lt y gt Meaning SB lt x gt Node lt y gt was removed This indicates that OS removes SB lt x gt and Node lt y gt dr util INFO 822 Remove CPU x total lt y gt Meaning CPU x total lt y gt will be removed This indicates that OS will remove CPU lt x gt total y of CPUs dr util INFO 823 Removed CPU x total lt y gt Meaning CPU lt x gt total lt y gt was removed This indicates that OS removed CPU lt x gt total lt y gt of CPUs dr util INFO 824 Remove MEM x total lt y gt Meaning Memory lt x gt total lt y gt kB will be removed This indicates that OS will remove memory lt x gt total lt y gt kB dr util INFO 825 Removed MEM x total lt y gt Meaning Memory lt x gt total lt y gt kB was removed This indicates that OS removed memory lt x gt total y kB dr util INFO d Execute x user programs at y timing ed 826 827 Meaning x of collaboration programs will be executed at lt z gt timing lt z gt represents before or after dr util INFO 828 Executed user programs at x timing Meaning Collaboration programs executed at x timing x represents before or after dr util INFO 829 Removed SBex gt Meaning The remo
208. of this product or transferring it as is may enable third parties to access the data on the hard disk and use it for unforeseen purposes To prevent the leakage of confidential information and important data all of the data on the hard disk must be erased before disposal or transfer of the product However it can be difficult to completely erase all of the data from the hard disk Simply initializing reformatting the hard disk or deleting files on the operating system is insufficient to erase the data even though the data appears at a glance to have been erased This type of operation only makes it impossible to access the data from the operating system Malicious third parties can restore this data If you save your confidential information or other important data on the hard disk you should completely erase the data instead of simply carrying out the aforementioned operation to prevent the data from being restored To prevent important data on the hard disk from being leaked when the product is disposed of or transferred you will need to take care to erase all the data recorded on the hard disk on your own responsibility Furthermore if a software license agreement restricts the transfer of the software operating system and application software on the hard disk in the server or other product to a third party transferring the product without deleting the software from the hard disk may violate the agreement Adequate verification from this point of
209. om that for actual operation The PDF file of this manual is intended for display using Adobe Reader in single page viewing mode at 100 zoom This manual shall not be reproduced or copied without the permission of Fujitsu Limited Copyright 2014 2015 FUJITSU LIMITED Xi CA92344 0540 05 Overview of Messages Contents CHAPTER 1 Overview of Messages tecti e e Denn tee cH ente i eoe IR Rc He teer er DH n dide DR nasa EEEE 1 1 1 Howto read the MMB Messages intraret regretter tertie ttg ertet br Pepe bn ep etae prie ep erbe etg ebbe ph aie ipa tia 1 1 4 1 system event l0g oe ee t e IR E ER E ERREUR CUR UI AER ne EE Er OUR edi eee 1 GHAPTER2 MMB Messages x citt ed c aetti peo dede donet oder IS dat editado to ecoute Ma ecu torpet 3 2 1 MMB Message list uU eR E Ep UE A elut etes lecti ieu diee es AQ ei aae iaeia 3 2 1 1 Temperature sensor related messages iiec een entente tnnt th teta tente tenth tese seht ta teta 4 2 1 2 Voltage Sensor Related it en e ee tte rete n iue ii s 5 2 1 8 Fan Related cR RR RE RARE ERE T 2 1 4 PSU and DDG related ii cen ene ead 8 2 1 5 IMIMIB related eis fiesta uU EE a a UIN RISE M E ME EL LU 11 2 1 6 SB Memory Scale up Board IOU DU MMB OPL related eese eterne nter ntn tnter nnns 20 2 1 7 Mezzarnine related rti te iter col hab d ie daa Ed ee bo d a d b edd a d n on ned eo 21 2 1 8 POI Boxirelated s cotto terere hatte t aiu MIL
210. on SB xx Other than those above SB xx 211 CA92344 0540 05 CO FUJITSU
211. on for the CLI command line interface The following notation is used for commands Command syntax Command syntax is represented as follows Variables requiring the entry of a value are enclosed in angle brackets lt gt Optional elements are enclosed in brackets Options for optional keywords are grouped in stroke separated lists enclosed in brackets Options for required keywords are grouped in stroke separated lists enclosed in braces Command syntax is written in a box Remarks The command output shown in the PDF manuals may include line feeds at places where there is no line feed symbol at the end of the line Notes on notations If you have a comment or request regarding this manual or if you find any part of this manual unclear please take a moment to share it with us by filling in the form at the following webpage stating your points specifically and sending the form to us https www s fujitsu com global contact computing IPRMQST feedback html The contents of this manual may be revised without prior notice In this manual the Management Board and MMB firmware are abbreviated as MMB In this manual IOU 10GbE and IOU 1GDE are collectively referred to as IO Units Screenshots contained in this manual may differ from the actual product screen displays The IP addresses configuration information and other such information contained in this manual are display examples and differ fr
212. on in the CPU mounting conditions Corrective action Check the CPU mounting location Severity Warning B0076B00 CPU PECI access error Meaning A CPU error has occurred Corrective action Replace the CPU Severity Error 29 CA92344 0540 05 MMB Messages B0076B01 CPU Information ROM access error Meaning A CPU error has occurred Corrective action Replace the CPU Severity Error B0076B02 CPU boot code error Meaning A CPU error has occurred Corrective action Replace the CPU Severity Error B0076B03 CPUZ register verify error Meaning A CPU error has occurred Corrective action Replace the CPU Severity Error B007A100 CPUZO CPU failure predicted Meaning The threshold of correctable CPU errors has been exceeded Corrective action Replace the CPU Severity Warning B007A101 CPU 1 CPU failure predicted Meaning The threshold of correctable CPU errors has been exceeded Corrective action Replace the CPU Severity Warning B00707FF CPU CPU added Meaning A CPU has been added Corrective action No action is necessary Severity Info uSystem Firmware Progress related BMC BOOFEO5F Server Management Configuration NVRam bad default configuration is used Meaning An error occurred in BAC NVRAM Corrective action Replace the SB Severity Warning 30 CA92344 0540 05 MMB Messages BOOFEOC8 POST
213. onent list 1 Severity Error BC5040D0 PCI Flow Control Protocol Error Bus Device 0x Function 0x Meaning An error was detected in the Link control system of the PCI express Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type B in the TABLE A 1 Replacement component list 1 Severity Error BC5040E0 PCI Completion Time out Bus Device 0x Function Ox Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error 41 CA92344 0540 05 MMB Messages BC5040F0 PCI Completer Abort Bus Device 0x Function Ox Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC504100 PCI Unexpected Completion Bus Device 0x Function Ox Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error
214. onfigured Meaning The PRO 1000 adapter is not properly configured in the PCI BIOS Corrective action If the unit name is IOB n PCIC n FUNC n or PCI Boxzn PCIC4Zn FUNCZn Try again with another PCI slot Alternatively replace the adapter If the unit name is SB n NIC Replace the SB Severity Error 21711 Adapter error Not configured for bus mastering Meaning The adapter is not configured for bus mastering in the PCI BIOS Corrective action If the unit name is IOUZn PCICzn FUNCZn or PCI Boxi n PCICzZn FUNCZn Mount the adapter in a slot that supports bus masters If the unit name is SB n NIC Replace the SB Severity Error 112 CA92344 0540 05 MMB Messages 21716 Adapter error EEPROM error Meaning An error may have occurred in the EEPROM of the adapter Corrective action Replace the adapter Severity Error 21719 Adapter error Could not start Meaning A connection to a supported gigabit network could not be started Corrective action Connect the cable to the network port and perform a restart Alternatively disable link based login and perform a restart Severity Error 21725 Adapter error NOT properly configured Meaning A gigabit network connection is not properly configured in the PCI BIOS Corrective action Try again with another PCI slot Alternatively replace the adapter Severity Error 21726 Adapter error Not configured for bus ma
215. or Bus Device 0x Function 0x Meaning An internal error was detected in the PCI express Device Corrective action No action is necessary Severity Info BC5050F0 PCI Header Log Overflow Bus Device 0x Function Ox Meaning Many errors were detected in the PCI express packet and the log overflowed Corrective action No action is necessary Severity Info 44 CA92344 0540 05 MMB Messages BC507000 Driver Monitor Information Message ID Meaning An informative event from PCI card driver occurred Corrective action No action is necessary Severity Info BC508000 Driver Monitor Warning Message ID Meaning A warning was detected by PCI driver Corrective action Source of SEL is blank After checking Message ID in the SEL message refer to 2 2 List of SVAS messages to take appropriate action Severity Warning BC509000 Driver Monitor Error Message ID Meaning An error was detected by PCI driver Corrective action Source of SEL is blank After checking Message ID in the SEL message refer to 2 2 List of SVAS messages to take appropriate action Severity Error BC547000 Driver Monitor Information Segment Bus Device 0x Function 0x Message ID Meaning An informative event from PCI card driver occurred Corrective action No action is necessary Severity Info BC548000 Driver Monitor Warning Segment Bus Device 0
216. or was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070380 Diag General Purpose Register Error Meaning A register write error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070382 Diag SDRAM Correctable Error Meaning Correctable error has occurred in SDRAM Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070383 Diag RTC Time Error Meaning An internal clock error has occurred Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070384 Diag L2 Cache Correctable Error Meaning A L2 cache correctable error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070385 Diag System EEPROM Checksum Error Meaning An EEPROM checksum error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070387 Diag CPLD Revision Register Error Meaning A CPLD read error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 16 CA92344 0540 05 MMB Messages 15070
217. ot match Corrective action Re confirm the entered Password Severity Warning Failed to get login information Meaning Acquisition of login user information has failed Corrective action As acquisition of login user information had failed the login user information of only the local MMB is displayed If need retry processing if it fails again contact your sales representative or a field engineer Severity Error Failed to get the firmware version Meaning Acquisition of firmware version has failed Corrective action Check the details of the error in the System Event Log and update the firmware again Severity Error Error The checksum of the firmware file is invalid Meaning Checksum error has occurred in the firmware Corrective action Check the specified file Severity Error Error The size of the firmware file is invalid Meaning The firmware file size is invalid Corrective action Check the specified file Severity Error Error The CRC of the firmware file is invalid Meaning The CRC check result of the firmware file is invalid Corrective action Check the specified file Severity Error Error Specified file is NOT a Firmware file Meaning The specified file is not a firmware file Corrective action Check the specified file Severity Error Unable to execute the update under maintenance Meaning The firmware cannot be updated during maintenance Correctiv
218. oved Meaning The PSU was removed Corrective action No action is necessary Severity Info O8EFO3FF Power Supply input is restored Meaning The power supply was restored Corrective action No action is necessary Severity Info O90BO0FF Fully Redundant Meaning The PSU are configured redundantly Corrective action No action is necessary Severity Info 090B0300 Non redundant Sufficient Resource in system power off state Meaning The system has the minimum required power configuration for system operation Corrective action No action is necessary Severity Info 090B03FF Non redundant Sufficient Resource Meaning The PSUs are not configured redundantly Corrective action No action is necessary Severity Warning in case that PSU redundant mode is Redundant Info in case that PSU redundant mode is Non Redundant 090B0500 Non redundant Insufficient Resource in system power off state Meaning The mounted PSUs for are not sufficient for system operation Corrective action No action is necessary Severity Info 10 CA92344 0540 05 MMB Messages 2 1 5 O90BO5FF Non redundant Insufficient Resource Meaning The mounted PSUs are not sufficient for system operation Corrective action Check for any faulty PSU and if the mounted PSUs are sufficient for system configuration Severity Error MMB related MMB related messages are lased below 15070103 Chass
219. partition Severity Warning The specified SB x is not supported Meaning The command cannot be performed in the specified SB Corrective action Confirm that the SB is correctly specified Also confirm the configuration of the partition Severity Warning Unable to add the specified SB x to the partition due to CPU mismatch between SBs Meaning The specified SB cannot be added as there is CPU mismatch between the SBs Corrective action Make sure that the CPUs mounted on the SBs configuring the partition are the same Severity Warning Unable to add the specified SB x IOUZx Extended Partitioning x to the partition because the specified SB x IOUZx Extended Partitioning x status is failed Meaning A failed SB IOU or Extended Partitioning cannot be added to a partition Corrective action Replace the SB IOU Extended Partitioning with a normal one Severity Warning Unable to execute this command because the system is under maintenance Meaning This command cannot be executed because the system is under maintenance Corrective action Execute the operation after the maintenance has been completed Severity Warning 126 CA92344 0540 05 MMB Messages Unable to execute this command because the Partition x is under maintenance Meaning This command cannot be executed because Partition x is under maintenance Corrective action Execute the operation after the maintenance has been completed
220. pe A in the TABLE A 1 Replacement component list 1 Severity Error 40 CA92344 0540 05 MMB Messages BC5030F0 Legacy PCI SERR Bus Device 0x Function Ox Meaning An error was detected in the PCI or PCI express data Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC504040 PCI Data Link Protocol Error Bus Device 0x Function 0x Meaning An error was detected in the PCI express Link control system Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type B in the TABLE A 1 Replacement component list 1 Severity Error BC504050 PCI Surprise Down Error Status Bus Device 0x Function 0x Meaning An error has occurred in the PCI express transmission system Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type B in the TABLE A 1 Replacement component list 1 Severity Error BC5040C0 PCI Poisoned TLP Bus Device 0x Function 0x Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement comp
221. peration will come soon If the device is still used it will be switched to the Read Only mode and then the data will NOT be written to the device anymore Corrective action Replace the PCle SSD card to the new one which is already purchased Severity Info 29115 Adapter error Reliability degraded 2 0TB card Meaning The reliability is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 124 CA92344 0540 05 MMB Messages 2 3 29116 Adapter error Temperature above warning threshold 2 0TB card Meaning Temperature exceeded the upper warning threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 29117 Adapter error Adapter removed 2 0TB card Meaning Adapter is removed Corrective action Replace the PCle SSD card Severity Warning List of CLI messages This section lists the messages related to the CLI Are you sure you want to add s to Partition d Y N Meaning Confirmation as to whether SB IOU or Extended Partitioning is to be added to the partition Corrective action No action is necessary Severity Info Adding s to Partition d has been completed successfully Meaning SB IOU or Extended Partitioning has been added to the partition normall
222. place the HDD Severity Warning 64 CA92344 0540 05 MMB Messages E77E04FF Logical drive bad block table is full Meaning The bad block table of logical drive is full Corrective action Check added error messages for the logical drive Severity Warning E77E03FF Logical drive failed Meaning The logical drive broke down Corrective action It is likely to be able to recover without losing data Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning 297F01FF BBU on RAID controller on battery Meaning The RAID card runs with the battery Corrective action Confirm the power supply to the RAID card Severity Warning 297F02FF BBU on RAID controller battery low Meaning The battery voltage reduction was detected Corrective action Confirm whether the cable is correctly connected Still when the problem continues it is necessary to exchange the FBU Severity Warning 297F0500 BBU on RAID controller failed Meaning The battery breakdown was detected Corrective action The calibration of the FBU is executed It takes about one day to the completion of this process Confirm whether the cable is correctly connected when the problem continues When the problem is not canceled it is necessary to exchange the FBU Severity Warning 297F0501 BBU on RAID controller temperature problem detected
223. ply input over voltage warning Meaning Input over voltage warning has occurred Corrective action Replace the target PSU Severity Warning 086F0206 Power Supply input over power warning Meaning Input over power warning has occurred Corrective action Replace the target PSU Severity Warning 086F02FF Predictive Failure Meaning The rpm of the PSU built in FAN has decreased Corrective action Replace the target IO PSU Severity Warning 086F0300 Power Supply input lost in system power off state Meaning Power supply from the PSU has failed Corrective action Check the input power Severity Info 086FO03FF Power Supply input lost Meaning Power failure was detected Corrective action 1 Checkthe AC input 2 Checkthe AC cable connection 3 Replace with the appropriate PSU Severity Error 086F05FF Power Supply input out of range but present Meaning 100V 200V AC cable connection is incorrect Corrective action Check the AC cable connection Severity Error 086F0601 Configuration error Meaning PSU with incorrect specifications is mounted or different types of PSUs are mixed Corrective action Replace with the appropriate PSU Severity Error 9 CA92344 0540 05 MMB Messages 086F0602 Configuration error in excess unit Meaning PSU mounting location is wrong Corrective action Check the PSU mounting location Severity Error O8EFOOFF Rem
224. r Severity Error C8A1041B PCle SW Upstream ACS Violation Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error 53 CA92344 0540 05 MMB Messages C8A1041C PCle SW Upsiream Uncorrectable Internal Error Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10490 PCle SW Downstream Data link Protocol Error Meaning An error has occurred in the switch Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10491 PCle SW Downstream Surprise Down Error Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10492 PCle SW Downstream Poisoned TLP Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10493 PCle SW Downstream Flow Control Protocol Error Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representat
225. r Temperature above warning threshold Meaning The temperature has exceeded the warning threshold Corrective action Check the ambient temperature and reduce the write load Severity Warning 28727 Adapter error Memory is close to wearing out Meaning The system is running short of memory Corrective action Check the format size Release reserved space by formatting with a smaller size Severity Warning 28728 Adapter error Non optimal PCI slot bandwidth Meaning The PCI slot does not have the optimal bandwidth Corrective action Reinstall the adapter at an appropriate PCI slot Severity Warning 28729 Adapter error Power loss protection disabled Meaning Power loss protection is disabled Corrective action Collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28730 Adapter error Write regulation activated due to power constraints Meaning Writing is restricted because of PCI slot power constraints Corrective action Collect investigation materials e g fjsnap PrimeCollect and contact your sales representative or a field engineer Severity Warning 28731 Adapter error Write regulation activated due to high temperature Meaning Writing is restricted because of high temperature Corrective action Check the ambient temperature and reduce the write load Severity Warning 119 CA9
226. r a field engineer Severity Error 52 CA92344 0540 05 MMB Messages C8A10415 PCle SW Upsiream Completer Abort Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10416 PCle SW Upstream Unexpected Completion Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10417 PCle SW Upstream Receiver Overflow Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10418 PCle SW Upstream Malformed TLP Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10419 PCle SW Upstream ECRC Error Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A1041A PCle SW Upstream Unsupported Request Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field enginee
227. r user The message asks for confirmation to continue Corrective action Check the usage status of aa If there is no problem click the OK button Otherwise click the Cancel button Severity Info W 00215 Failed to power on aa but maintenance will still continue After Maintenance completion Check the System Event Log Window to refer to the error details Meaning Power was turned on but was timed out since the power status was unchanged for a certain period of time or aa power on process was terminated abnormally due to an error in the unit Corrective action The power on process has failed but since it does not affect the maintenance work continue the operation Check the system event log after the completion of the maintenance work Severity Warning W 00216 Failed to power off aa but maintenance will still continue After Maintenance completion Check the System Event Log Window to refer to the error details Meaning Power was turned off but was timed out since the power status was unchanged for a certain period of time Or aa power off process was terminated abnormally due to an error in the unit Corrective action The power off process has failed but since it does not affect the maintenance work continue the operation Check the system event log after the completion of the maintenance work Check the system event log after the completion of the maintenance work Severity Warning 00217 U
228. radation was detected in the interface between CPU Memory Scale up Controller with Memory Buffer Corrective action The target CPU SB Memory Scale up Board or Mezzanine must be replaced Contact your sales representative or a field engineer Severity Warning PCI Express related Messages related to PCI Express are listed below C76F01FF Failed Meaning A clock error has occurred Corrective action SB must be replaced Contact your sales representative or a field engineer Severity Error C8A10410 PCle SW Upstream Data link Protocol Error Meaning An error has occurred in the A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10412 PCle SW Upstream Poisoned TLP Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10413 PCle SW Upstream Flow Control Protocol Error Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative or a field engineer Severity Error C8A10414 PCle SW Upstream Completion Timeout Meaning A switch port error has occurred Corrective action The target SB IOU or PCI Box must be replaced Contact your sales representative o
229. re during Power Management Bootup Meaning Firmware is not exist or not running Corrective action Replace the HBA Severity Warning 12556 Adapter error Hardware Initialization Failed Meaning Hardware is not initialized or not working correctly Corrective action Replace the HBA Severity Warning 12557 Adapter error OSM Hardware Initialization Failure Meaning Hardware is not initialized or not working correctly It might be a firmware problem Corrective action Replace the HBA Severity Warning 12558 Adapter error Unrecoverable Error Meaning Hardware error or exception which is not handled on Hardware and Firmware has occurred Corrective action Replace the HBA Severity Warning 12559 Adapter error Connection to the target was lost Meaning The connection to the target device is lost Corrective action Check the connection path cable switch HBA disk device port etc If the error keeps recurring contact your sales representative or a field engineer Severity Warning 88 CA92344 0540 05 MMB Messages SCSI Linux related 13007 Adapter error Not initialize properly Meaning Adapter initialization failed during adapter installation Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13008 Adapter error pci suspend IOC msg unit reset failed Meaning
230. re is unrecovered Partition can operate but DR function cannot use until the power of the partition is turned off and turned on again Corrective action Please deal with it according to SEL and syslog of OS Please turn off the power of specified partition and turn on it again The specified SB lOU is free Meaning The specified SB IOU cannot remove because it is not constituent of the partition Corrective action Please confirm configuration of partition The specified SB lOU is power off Meaning The specified SB IOU is power off state Corrective action Please confirm configuration of partition DR sequence timeout SB hot remove OS failure Meaning Timeout of DR sequence occurred in OS processing Corrective action Please deal with it according to SEL and syslog of OS 150 CA92344 0540 05 MMB Messages DR sequence timeout QPI disconnection failure Meaning Timeout of DR sequence occurred in disconnection QPI and the partition is reset Corrective action Please execute the following 1 Download SEL and contact your sales representative or a field engineer 2 Please process it according to SEL if reset of the partition is failed Please use it continuously if reset of the partition is success The specified OU has not stopped Meaning Stopping of the specified IOU is failed Corrective action Confirm that OS operation stopped Please try again If it fails confirm syslog of OS
231. receiving msg from VF Meaning Messages from the VF cannot be received Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11834 Adapter error Network adapter has over heated Meaning The adapter has stopped because of overheating Restart reset the adapter If the problem persists even after an adapter restart power off the system and replace the adapter Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 81 CA92344 0540 05 MMB Messages 11836 Adapter error should not be a VF Meaning The ID assigned to the PF should be assigned to the VF Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11848 Adapter error eeprom read failed Meaning Reading of EEPROM is failed Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11849 Adapter error ixgbe_watchdog_link_is_down NIC CNA Link is Down Meaning In iSCSI configuration the connection to target device is lost Corrective action Check the connection path cable switch HBA disk device port etc If the error keeps recurring contact your sales representative or a field engineer Severity Warning 11850 Adapter error ixgbe Failed to allocate MSI X interupts Meaning Allocation of MSI X interrupt
232. rective action If the problem persists even after waiting for one minute and selecting the menu again contact your sales representative or a field engineer Severity Error E 00055 Failed to restore the MMB Configuration Meaning Restoration of the MMB configuration information has failed Corrective action If the problem persists even after retrying contact your sales representative or field engineer Severity Error E 00056 Failed to backup the MMB Configuration Meaning Saving of MMB configuration information has failed Corrective action If the problem persists even after retrying contact your sales representative or field engineer Severity Error E 00057 Specified file cannot restore Meaning The entered file is outside the restoration target The file specified as the restoration target is not the MMB BIOS configuration information backup file Corrective action Specify the correct file Severity Error 156 CA92344 0540 05 MMB Messages W_00068 There are no available units on which maintenance can be performed Please check that you selected the right type of unit then check that the power status of partitions is Standby in the Partition Power Control Window and that there are available free units in the Partition Configuration Window Then please try again Meaning There is no unit for maintenance Check if the selected unit is correct and power status is Standby in the parti
233. representative or a field engineer Severity Warning 13032 Adapter error Diagnostic reset FAILED Meaning The diagnostic reset of the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13036 Adapter error Doorbell ACK timeout Meaning The adapter could not clear the Doorbell S status bit Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13037 Adapter error Doorbell INT timeout Meaning The adapter could not set the Doorbell INT status bit Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13038 Adapter error Handshake reply failure Meaning Handshake reply to from the adapter failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 91 CA92344 0540 05 MMB Messages 13040 Adapter error Firmware Reload FAILED Meaning The reload of firmware failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13041 Adapter error Cannot recover Meaning The adapter reset failed Corre
234. rity Warning 00210 Please select a maintenance area Meaning The maintenance area Partition System had not been specified when the Next button in the Maintenance Wizard Maintenance Area window was clicked Corrective action Specify the maintenance area Severity Info W 00210 Failed to restore PCI Box FAN Speed Mode but maintenance will still continue After Maintenance completion Check the System Event Log Window to refer to the error details Meaning When the FAN speed restoration process of the PCI Box was abnormally terminated when returning to the previous window by clicking the Previous button from the replacement confirmation window during Hot System Maintenance Warm System Maintenance Failed to restore the FAN speed of the PCI Box The process will continue but check the system event log after completion of the maintenance work is notified Corrective action Failed in restoring the of the PCI Box FAN speed but since this does not affect the maintenance operation continue with the operation Check the system event log after completing the maintenance work Severity Warning 00211 Log files have not been saved Are you sure you want to continue Meaning The confirmation window appears when the Next button in the log saving window is clicked without saving the log data asking whether to proceed to the next window without saving the log files Corrective action If the log files ne
235. rmance of device may be limited Corrective action No action is necessary Severity Info CDEFO1FF Power Saving Stopped Meaning The power saving is stopped and power is normal Corrective action No action is necessary Severity Info CD6F02FF Power Saving Started Meaning The power consumption of device exceeded the threshold set up by power saving management in MMB Web Ul Corrective action Check the device status Please prevent the rising of the load of device in order to limit power consumption If this situation continues the action which set in Power Management Setup menu of MMB Web UI is executed Severity Warning CD6F03XY Power Saving Partition XY powered off by limit reached Meaning The partition is powered off by power saving function since the state that power consumption exceeds the set threshold continued Corrective action Check the device status and the setting of power saving Severity Info 2 1 22 SSD related The messages related to SSD are listed below C8AB1000 SSD Rated Write Endurance has reached 30 Meaning SSD Rated Write Endurance has reached 30 Corrective action No action is necessary Severity Info 74 CA92344 0540 05 MMB Messages C8AB1001 SSD Rated Write Endurance has reached 50 Meaning SSD Rated Write Endurance has reached 50 Corrective action Please confirm the usage condition of SSD and prepare the replacement part of SSD if n
236. roblems the OK button is clicked and the subsequent window is displayed If there is a problem confirm the target unit after clicking the Cancel button Severity Info W 00207 The power status of the chassis is now Standby The selected Maintenance Operation Mode has become unavailable Check the system power status in the Power Supply Window Then please try again Meaning After Hot System Maintenance is selected and the Next button is clicked if the power status of the system chassis goes to Standby due to a user operation Maintenance cannot be performed in the selected maintenance mode as the power status of the system chassis has been changed Check the status of the System chassis and try again is notified Corrective action Check the power status of the system in the Power Supply window If the status is Standby ask the system administrator to turn on the power of the system chassis After confirmation perform the maintenance work again Severity Warning 00208 Please select partition s Meaning Displayed when partition is not specified and the Next button is clicked in the Maintenance Wizard Maintenance Area window Corrective action Specify the partition Severity Info 163 CA92344 0540 05 MMB Messages W_00208 The power status of one of the partitions is now On The selected Maintenance Operation Mode has become unavailable Please check that the power status of pa
237. rom Partition Y Meaning Reserved SB X that was set in Partition Y was removed Corrective action No action is necessary Severity Info C5A350XY If SB X replace with Reserved SB in Partition Y Memory Mirror is disabled Meaning Mirror Mode setting was Disabled when incorporating a Reserved SB that had been set Corrective action No action is necessary Severity Info CPU Memory Scale up Controller Memory Buffer related CPU Memory Scale up Controller or Memory Buffer related messages are listed below C8A00600 Correctable QPI Path error SB x CPU Y Meaning A correctable error was detected in the QPI transmission path between the CPUs or Memory Scale up Controllers Maximum two CPUs or Memory Scale up Controllers that detected the error are specified in Corrective action No action is necessary Severity Info 50 CA92344 0540 05 MMB Messages C8A10600 Uncorrectable Internal error Meaning An Uncorrectable CPU or Memory Scale up Controller error has occurred Corrective action CPU or Memory Scale up Board must be replaced Contact your sales representative or a field engineer Severity Error C8A10601 Uncorrectable QPI Path error SB x CPU Y Meaning An uncorrectable error was detected in the QPI transmission path between the CPUs or Memory Scale up Controllers Maximum two CPUs or Memory Scale up Controllers that detected the error are specified in Corrective action
238. ror dual plane mode failed Meaning The setting of Nand Flash to Dual Plane mode failed during driver loading Corrective action Collect the data for investigation dump or fjsnap Ask your sales representative or a field engineer to perform an investigation Severity Warning 99 CA92344 0540 05 MMB Messages 13903 Adapter error hardware failure Meaning An error occurred during driver loading Corrective action Collect the data for investigation dump or fjsnap Ask your sales representative or a field engineer to perform an investigation Severity Warning 13904 Adapter error Entering reduced write mode Meaning The adapter entered reduced write mode Corrective action Replace the adapter Severity Warning 13905 Adapter error Entering read only mode Meaning The adapter entered read only mode Corrective action Replace the adapter Severity Warning mSCSI common Linux related 14016 Device error Error with sense data Meaning An error with sense data occurred in the device Corrective action Check the sense key of the original data to decide on the corrective action Medium Error Perform cleaning Replace the tape Illegal Request Examine the software Data Protect Check whether the media is write protected Blank Check A tape positioning error Check operation Unit Attention A reset occurred or the media was replaced If there is a problem with the reset examine the HBA
239. ror is detected before SVAS SVagent V7 10 14 but corrective action is not needed 12222 Adapter error HBA Unrecoverable error Meaning An unrecoverable error occurred in the HBA Corrective action An HBA has a fault Replace the HBA If the error keeps recurring after replacement collect the data for investigation dump or fjsnap and ask your sales representative or a field engineer to perform an investigation Severity Warning 12238 Adapter error posting all rpi headers Meaning The addition of all RPI resources has failed Corrective action An HBA has a fault Replace the HBA If the error keeps recurring after replacement collect the data for investigation dump or fjsnap and ask your sales representative or a field engineer to perform an investigation Severity Warning 86 CA92344 0540 05 MMB Messages 12446 Adapter error Uncorrected error in the card Meaning An unrecoverable error occurred in the HBA Corrective action An HBA has a fault Replace the HBA If the error keeps recurring after replacement collect the data for investigation dump or fjsnap and ask your sales representative or a field engineer to perform an investigation Severity Warning 12452 Adapter error Firmware on card is old IRQs may not work Meaning Since firmware on an adapter is old version IRQ may not work Corrective action Update firmware on an adapter to version 4 0 or later Severity Warning
240. roughly to understand the information in it before using this product Be sure to keep this manual in a safe and convenient location for quick reference Fujitsu makes every effort to prevent users and bystanders from being injured and to prevent property damage Be sure to use the product according to the instructions in this manual Exportation release of this document may require necessary procedures in accordance with the regulations of the Foreign Exchange and Foreign Trade Control Law of Japan and or US export control laws Manuals for the PRIMEQUEST 2000 series The following manuals have been prepared to provide you with the information necessary to use the PRIMEQUEST 2000 series You can access HTML versions of these manuals at the following sites Japanese language site htto p fujitsu com platform server primequest manual 2000 Global site htto Awww fujitsu com global services computing server primequest htto manuals ts fujitsu com Title Description Manual code PRIMEQUEST 2000 Series Getting Describes what manuals you should read and how to access CA92344 0522 Started Guide important information after unpacking the PRIMEQUEST 2000 series server This manual comes with the product PRIMEQUEST 2000 Series Safety Contains important information required for using the CA92344 0523 and Regulatory Information PRIMEQUEST 2000 series safely PRIMEQUEST 2000 Series Describes the functions and features of the PRIMEQU
241. rtitions is Standby in the Partition Power Control Window Then please try again Meaning After Warm System Maintenance or Cold System Maintenance is selected and the Next button is clicked if the power status of the target partition has been changed due to a user operation Maintenance cannot be performed in the selected maintenance mode as the power status of the partition has been changed Check the partition status and try again is notified Corrective action Check the power status of the partition in the Partition Power Control window If the status is On ask the System administrator to turn off the partition power After confirmation restart the maintenance work Severity Warning W 00209 Failed to restore FAN Speed Mode but maintenance will still continue After Maintenance completion Check the System Event Log Window to refer to the error details Meaning If FAN speed restoration process which is executed when returning to the previous window by clicking the Previous button during Hot System Maintenance Warm System Maintenance is abnormally terminated Failed in restoring the FAN speed The process will continue but check the system event log after completion of the maintenance work is notified Corrective action Failed in restoring the FAN speed but since this does not affect the maintenance operation continue the operation Check the system event log after completing the maintenance work Seve
242. s MPD Linux related 15039 Adapter or Device or FC Network error MPD detected event Meaning The multipath driver detected an I O or FC multipath configuration error Corrective action Take corrective action according to the messages that the multipath driver outputs and the instructions in the ETERNUS Multipath Driver User s Guide Severity Warning mGLS Linux related 17001 Network error poll fail retry over polling stop Meaning A transmission path error occurred Polling failed successively until the retry count reached the specified number The HUB monitoring function will be disabled Corrective action Check the transmission path After the normal operation of the transmission path is restored disable and enable the HUB monitoring function Severity Error 17002 Network error primary polling failed Meaning An initial check of a physical interface detected an error in the path to the primary monitoring target Corrective action Confirm that the communication path to the monitoring target has no problems Severity Error 17003 Network error secondary polling failed Meaning An initial check of a physical interface detected an error in the path to the secondary monitoring target Corrective action Confirm that the communication path to the monitoring target has no problems Severity Error 17004 Network error Primary polling failed Meaning Transmission path monitoring o
243. s is failed Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 12005 Device or FC Network error Nodev timeout Meaning The driver lost the connection destination A device lost time out occurred Corrective action Check the connection path cable switch HBA disk device port etc If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12015 Adapier error stray mailbox interrupt mbxCommand Meaning The completion of a mailbox command that had supposedly not been issued was reported Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 82 CA92344 0540 05 MMB Messages 12016 Adapter error CONFIG LINK mbxStatus Error Meaning A CONFIG_LINK mailbox command was issued but it failed Corrective action Hardware or firmware has a fault If the error keeps recurring contact your sales representative or a field engineer Severity Warning 12023 Adapter error READ SPARM mbxSiatus error Meaning The driver issued a READ SPARM command but it failed Corrective action Hardware or firmware has a fault Contact your sales representative or a field engineer Severity Warning 12024 Adapter error CLEAR LA mbxSiatus error Meaning The driver issued a CLEAR LA mailbox command to th
244. s lost 96s is disk enclosure model name Corrective action Exchange the broke down PSU Severity Warning 70 CA92344 0540 05 MMB Messages C9A10F90 EMM Zn failed PCIBox or IOU n Slot n Port n Cascade s Meaning Problem of enclosure management module is detected 96s is disk enclosure model name Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C9A10F91 EMM Zn removed PCIBox or IOU n Slot n Port n Cascade s Meaning Enclosure management module is removed 96s is disk enclosure model name Corrective action 1 Please power off the device and confirm status of HDD SAS cable and power supply 2 If the problem persists replace the backplane expander module and data cable Severity Warning C9A10F92 EMM n Enclosure firmware mismatch PCIBox or IOU n Slot n Port n Cascade s Meaning Firmware version of enclosure management module is mismatch 96s is disk enclosure model name Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C9A10FA0 Enclosure shutdown PCIBox or IOU n Slot n Port n Cascade s Meaning Enclosure is done shutdown s is disk enclosure model name Corrective action Confirm status of enclosure Severity Warning C9A10FA1 Enclo
245. s missing This message appears when add only remove only set only show only is entered Corrective action Check the command parameter Severity Warning 127 CA92344 0540 05 MMB Messages Failed to execute remove partition command Meaning The remove partition command process has failed Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error The specified parameter is invalid Meaning An invalid parameter has been specified Corrective action Check the command parameter Severity Warning Unable to power on the Partition d due to CPU mismatch between SBs Meaning Power On has failed since Partition n contains different types of CPUs mixed between the SBs The message appears as in multiple lines if there are multiple partitions having CPU combination error Power On continues in partitions that do not have errors Corrective action Make sure that the CPUs mounted on the SBs configuring the partition are the same Severity Warning Unable to power on the Partition d Meaning Partition x cannot be powered On Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error Unable to power off the Partition d Meaning Partition x cannot be powered Off Corrective action Try setting again If it fails contact your sales representative or a field engineer Se
246. sary Severity Info E 00044 The Port number overlaps Meaning The port number has been duplicated with another port number in the MBB which was set in another window Corrective action Check the port number setting and set it again Severity Error E 00045 Free node doesn t exist Meaning There is no free node Displayed when an attempt is made to include a node in a partition where there are no free nodes Corrective action Set again after checking the configuration Severity Error 00046 Importing has completed Meaning Import has been completed Corrective action No action is necessary Severity Info CA92344 0540 05 MMB Messages E 00047 Importing failed Meaning Importing has failed Displayed when import of an SSL has failed Corrective action If the problem persists even after importing again contact your sales representative or a field engineer Severity Error E 00048 The specified unit is not installed Meaning The specified unit is not mounted Corrective action Install the specified unit Severity Error 00052 MMB switch processing has started Meaning Active MMB switching has started Corrective action No action is necessary Severity Info E 00053 Failed to get user status Retry 60 seconds later Meaning Acquisition of the user account status has failed due to resource insufficiency Display again after waiting for 60 seconds Cor
247. session The session was disconnected due to time out since there was no Web UI operation Corrective action Log in again Severity Info E 00012 One or more errors occurred while setting Meaning Error has occurred while setting Corrective action Retry the process If it fails contact your sales representative or a field engineer Severity Error 152 CA92344 0540 05 MMB Messages 00013 Setting completed Meaning Setting was successful Corrective action No action is necessary Severity Info 00015 It has already reached the maximum number of login users There is a possibility that the window was shut without logging out Please login again after it waits for a few minutes Meaning The maximum number of concurrent login sessions has been exceeded Corrective action Wait until the logged in user logs out However if the maximum number of concurrent login sessions has been exceeded due to unsuccessful log out wait for three minutes and then log in again Severity Info E 00018 Information acquisition failed Meaning Acquisition of information required for the window display has failed Corrective action Retry the process If it fails contact your sales representative or a field engineer Severity Error E 00019 Can t acquire the query string Meaning Acquisition of the query string has failed Corrective action Retry the process If it fails contact your sales r
248. ster the specified Partition d as Mirror Mode enable because of abnormal DIMM composition Meaning Unable to set the Mirror Mode for Partition d because there is a problem in the DIMM configuration Corrective action Check the DIMM configuration of the SB where the partition has been configured Severity Error The SB with DIMM that does not satisfy requirements of Mirror Mode is registered as a Reserved SB If you register this partition as a Mirror Mode Mirror Mode will be disabled when switching to Reserved SB Are you sure to continue Y N Meaning An SB containing a DIMM that does not satisfy the requirements of a Mirror Mode has been assigned as a Reserved SB If the specified Partition is registered as a Mirror Mode the Mirror Mode will be cancelled when switching over to the Reserved SB Confirmation is requested to continue processing Corrective action To continue with the setting enter Y To interrupt the setting enter N Severity Info Unable to add the specified SB to the partition due to SB composition abnormal Meaning Unable to add the specified SB because there is a configuration Corrective action Specify the appropriate SB Severity Error Unable to power on the Partition d due to abnormal SB composition Meaning Unable to power on the specified partition because there is an error in the SB configuration Corrective action Confirm the combination status of the SB which
249. stering Meaning A gigabit network connection is not configured for bus mastering in the PCI BIOS Corrective action Mount the adapter in a slot that supports bus masters Severity Error 21729 Adapter error EEPROM error Meaning An error may have occurred in the EEPROM for a gigabit network connection Corrective action Replace the adapter Severity Error 21802 Adapter error EEPROM error Meaning An error may have occurred in the EEPROM of the adapter Corrective action Replace the adapter Severity Error 21810 Adapter error The fan on the network adapter has failed Meaning An adapter failure occurred Corrective action Turn off the computer and replace the network adapter Severity Error 113 CA92344 0540 05 MMB Messages 21812 Adapter error MAC address is invalid Meaning The network adapter has an invalid MAC address Corrective action Replace the adapter Severity Error 21813 Adapter error overheated Meaning The network adapter has stopped because of overheating Corrective action Perform a restart If the problem persists turn off the computer and replace the network adapter Severity Error 21852 Adapter error EEPROM error Meaning An error may have occurred in the EEPROM of the adapter Corrective action Replace the adapter Severity Error 21854 Adapter error MAC address is invalid Meaning The network adapter has an inva
250. sure sensor bad PCIBox or IOU n Slot n Port n Cascade s Meaning Sensor of enclosure is fault s is disk enclosure model name Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C9A10FA2 Enclosure phy bad for slot x PCIBox or IOU n Slot n Port n Cascade s Meaning Problem of PHY of enclosure is detected s is disk enclosure model name Corrective action Please replace HDD Severity Warning 71 CA92344 0540 05 MMB Messages C9A10FA3 Enclosure unstable PCIBox or IOU n Slot n Port n Cascade s Meaning The operation of the enclosure is not steady s is disk enclosure model name Corrective action Please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C9A10FA4 Enclosure hardware error PCIBox or IOU n Slot n Port n Cascade s Meaning The problem of enclosure hardware is detected s is disk enclosure model name Corrective action 1 Please confirm the cable of enclosure 2 Please confirm that enclosure is operating 3 If the problem persists please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C9A10FA5 Enclosure not responding PCIBox or IOU Zn SlotZn Port n Cascade s
251. t Inc in the U S and other countries Intel Intel Logo Intel Inside Intel Inside Logo Intel Atom Intel Atom Inside Intel Core Core Inside Intel vPro vPro Inside Celeron Celeron Inside Itanium Itanium Inside Pentium Pentium Inside Xeon Xeon Phi Xeon Inside Ultrabook are trademarks of Intel Corporation in the U S and or other countries Ethernet is a registered trademark of Fuji Xerox Co Ltd in Japan and is a registered trademark of Xerox Corp in the United States and other countries VMware is a trademark or registered trademark of VMware Inc in the United States and other countries Novell and SUSE Linux Enterprise Server are trademarks of Novell Inc Xen is a trademark or registered trademark of Citrix Systems Inc or its subsidiaries in the United States and other countries Other company names and product names are the trademarks or registered trademarks of their respective owners Trademark indications are omitted for some system and product names in this manual x CA92344 0540 05 Overview of Messages Notation This manual uses the following fonts and symbols to express specific types of information Italics Font or symbols Meaning Example Title of a manual that you should refer to See the PRIMEQUEST 2000 Series Installation Manual CA92344 0536 Window names as well as the names of Click the OK button buttons tabs and drop down menus in windows are enclosed in brackets Notati
252. t failed in the retention test of the battery Corrective action Please recovery according to the error message When the problem is not canceled please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning C8A70E09 BBU on RAID controller communication error Meaning The communication error with FBU occurred Corrective action 1 Please confirm that data cable and power cable of FBU are correctly connected with RAID controller 2 Please confirm that latest firmware version of the RAID are installed 3 When the problem is not canceled it is necessary to exchange the FBU 4 When the problem is not canceled please gather the survey material because a detailed investigation is necessary for that and contact the repair chat channel Severity Warning E76F02FF Physical disk SMART error predictive failure model Meaning The HDD error was detected by self diagnosis Corrective action Replace the HDD In this event occurs MMB firmware disconnect the corresponding HDD in order to prevent system slow down However MMB firmware does not disconnect when it can cause data corruption Severity Warning E76F03FD Physical disk unexpected sense exceeded threshold model Meaning It was detected sense code beyond the threshold at the Physical Drive Corrective action Replace the HDD In this event occurs MMB firmware disconnect
253. t the corresponding HDD in order to prevent system slow down However MMB firmware does not disconnect when it can cause data corruption E76F0202 Physical disk n unexpected sense exceeded threshold model m predictive failure PCIBox or lOU n Slot n Port n Cascade s Meaning It was detected sense code beyond the threshold at the Physical Drive s is disk enclosure model name Corrective action Replace the HDD Severity Warning Remark In this event occurs MMB firmware disconnect the corresponding HDD in order to prevent system slow down However MMB firmware does not disconnect when it can cause data corruption E76F0300 Physical disk n failed model m PCIBox n Slot n Port n Cascade s Meaning The HDD error was detected s is disk enclosure model name Corrective action Replace the HDD Severity Warning Remark In this event occurs MMB firmware disconnect the corresponding HDD in order to prevent system slow down However MMB firmware does not disconnect when it can cause data corruption E76F0500 Physical disk n rebuilding model m PCIBox n Slot n Port n Cascade s Meaning The HDD rebuilding is in progress s is disk enclosure model name Corrective action No action is necessary Severity Info E76F0600 Physical disk n Global hot spare released model m PCIBox or l OU n Slot n Port n Cascade 96s Meaning A global hot spare of HDD was deleted s is disk enclosure mo
254. tact your sales representative or a field engineer Severity Warning 122 CA92344 0540 05 MMB Messages 29062 Adapter error Write operations disabled 1 6TB card Meaning Write operations are disabled Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 29063 Adapter error Temperature above error threshold 1 6TB card Meaning Temperature exceeded the upper error threshold Corrective action Reduce the load of writing operations Check the ambient temperature and system environment as well Severity Warning 29064 Adapter error Memory is close to wearing out 1 6TB card Meaning The product lifetime end for write operation will come soon If the device is still used it will be switched to the Read Only mode and then the data will NOT be written to the device anymore Corrective action Replace the PCle SSD card to the new one which is already purchased Severity Info 29065 Adapter error Reliability degraded 1 6TB card Meaning The reliability is degraded Corrective action It might be a temperature problem power unit problem or life cycle problem etc Contact your sales representative or a field engineer Severity Warning 29066 Adapter error Temperature above warning threshold 1 6TB card Meaning Temperature exceeded the upper warning threshol
255. ted and maintenance mode is released Severity Info 167 CA92344 0540 05 MMB Messages 00221 Unable to change Network Interface because the system is under maintenance Setting could not be done as the Network Interface is under maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info 00222 Unable to aa the Partition bb because this Partition is under maintenance Meaning The partition of aa cannot be operated because the Partition bb is under maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info 00223 Unable to change the specified SB s because the partition including the specified SB s is under maintenance Meaning The selected SB cannot be changed because it contains a partition that is under maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info 00224 Unable to execute aa Firmware Update on bb because cc is under maintenance Meaning The firmware cannot be updated for the aa firmware update target bb because cc is under maintenance Corrective action Wait until the maintenance work is completed and maintenance mode is released Severity Info W 00224 Failed to save log Please retry to save it After Maintenance completion Check the System Event Log Window to
256. ter If the problem persists hardware error on PCle line is suspected Replace the IOU or PCIBox connected to an adapter Severity Warning 79 CA92344 0540 05 MMB Messages 11802 Adapter error Fan has stopped Meaning An adapter error occurred Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11807 Adapter error link_config FAILED Meaning The condition and speed of the link cannot be set Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11808 Adapter error Unable to allocate MSI X interrupts Meaning The vector required for an MSI X interrupt cannot be assigned Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11815 Adapter error ixgbe_up failed after reset Meaning After a reset the card could not work well Corrective action An adapter failure may have occurred Replace the adapter Severity Warning 11816 Adapter or Software error HW Init failed Meaning Initialization of hardware failed Corrective action Collect the data for investigation dump or fjsnap Ask your sales representative or a field engineer to perform an investigation Severity Warning 11817 Adapter error Hardware Error Meaning A hardware error was detected Corrective action High probability of an adapter failure Proceed to adapter replacement Se
257. ter error Adapter removed 2 0TB card Meaning Adapter is removed Corrective action Replace the PCle SSD card Severity Warning 22126 Adapter error Uncorrectable error detected Meaning Uncorrectable error has occurred Corrective action Check if the driver version is the latest one If not update to the latest driver version If already the latest driver version replace the adapter Severity Warning 22127 Adapter error Hardware initialization failed failing driver load Meaning Hardware initialization is failed Failed to load the driver Corrective action Replace the adapter Severity Warning 111 CA92344 0540 05 MMB Messages 2 2 2 22132 Adapter error Failed to map Base Address Register failing driver load Meaning Failed to map Base Address Register and then failed to load the driver Corrective action Check if the driver version is the latest one If not update to the latest driver version If already the latest driver version replace the adapter Severity Warning 22133 Adapter error Hardware initialization has failed Meaning Hardware initialization has failed Corrective action Replace the adapter Severity Warning Windows related m LAN FC Windows related 21709 Adapter error Could not establish link Meaning A link cannot be established Corrective action Check the cable Severity Warning 21710 Adapter error NOT properly c
258. than OS kernel dr util ERR d Failed to send IPMI Command Completion d 600 602 Meaning Failed to send IPMI Command Corrective action Failed to send the completion notification of SB hot plug to MMB Please check MMB status 204 CA92344 0540 05 Dynamic Reconfiguration Messages dr util ERR d Failed to send IPMI Command Completion d 601 603 Meaning Failed to send IPMI Command Corrective action The action in OS is unnecessary though there is a possibility that error information on IOU hot plug is not correctly notified to MMB dr util ERR 622 x Permission denied lt y gt Meaning Collaboration program lt x gt has no appropriate permission Corrective action Collaboration program x has no appropriate permission Current mode is y Please add the execute permission to the collaboration program lt x gt dr util ERR 630 Failed to send IPMI Command OS Not Ready Meaning Failed to send IPMI Command Corrective action Please run etc init d FJSvdr util stop manually When the improvement is not seen trouble may occur in MMB dr util ERR 631 Failed to send IPMI Command OS Ready Meaning Failed to send IPMI Command Corrective action DR cannot be operated from MMB Please run etc init d FJSvdr util start manually When the improvement is not seen trouble may occur in MMB 3 5 Messages concerning DR command progress dr util INFO 800 Detected SB hot add Meani
259. the variables on the dump device Corrective action Set up sadump again WARNING The device DUMP DEVICEn open failed Trying next device Meaning The n th dump device n 1 3 could be opened Try next device Corrective action Restore dump device which could not be used Or set up sadump again WARNING The device DUMP DEVICEn is not a dump device Trying next device Meaning The n th device is not a dump device Try next device Corrective action Restore dump device which could not be used Or set up sadump again WARNING The device DUMP DEVICEn contains memory image Trying next device Meaning The n th dump device contains memory image Trying next device Corrective action If captured memory image is not needed initialize dump device If the memory image is needed save memory dump to the tape and initialize dump device WARNING Size of memory image exceeded capacity of dump device Meaning Size of memory image exceeded capacity of dump device Corrective action If possible use dump device whose capacity is bigger than current one 208 CA92344 0540 05 sadump Messages WARNING The device DUMP_DEVICEn is a dump device of another system Trying next device Meaning The n th dump device is used for another system Trying next device Corrective action Set up sadump again WARNING The device DUMP_DEVICE1 DUMP_DEVICE2 DUMP_DEVICE3 contains memory image DUMP_DEVICEn will be overwritten Meanin
260. tion Please change resources after power off the partition Severity Warning W 00590 The Unified Firmware Version is unknown Please retry to update the firmware Meaning The Unified Firmware Version is not recognized Corrective action Please retry to update the firmware Severity Warning E 00591 Unable to power on the partition d due to no Home Meaning The partition cannot power on because the partition has not a Home SB Corrective action Check the configuration of the partition Severity Error W 00593 Unable to add the specified SB to the partition due to Dynamic Reconfiguration Mode Meaning The specific SB cannot be added to the partition because the Dynamic Reconfiguration Mode is enabled Corrective action Please check the Dynamic Reconfiguration mode or check the SB status Please add the SB after Dynamic Reconfiguration Mode is disabled Severity Warning 193 CA92344 0540 05 MMB Messages W_00595 It is IP address that duplicates with s Meaning It is duplicated with IP address of s Corrective action Please change to a different IP address Severity Warning W_00596 It is the same subnet as MMB IP address Please change to a different subnet Meaning It is the same subnet as MMB IP address Corrective action Please change to a different subnet Severity Warning W_00597 A subnet differs from MMB IP address When you change a setup of Console Redirection IP
261. tion The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 92 CA92344 0540 05 MMB Messages 13107 Adapter error Error issuing abort task Meaning The result of Abort Task is displayed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13115 Adapter error Firmware Reload FAILED Meaning The reload of firmware failed Corrective action The HBA must be replaced If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13120 Adapter error detects pci parity error Meaning A parity error occurred during reading to PCI Corrective action The HBA must be replaced If the problem persists even after you replace the HBA replace the device e g PCI Box connected to the HBA Severity Warning 13121 Adapter error detects pci parity error Meaning A parity error occurred during reading to PCI The operation ran out of retries Corrective action The HBA must be replaced If the problem persists even after you replace the HBA replace the device e g PCI Box connected to the HBA Severity Warning 13122 Adapter error couldn t read pci register Meaning Reading of the PCI status register failed Corrective action The HBA must be replaced If the problem persists eve
262. tion of the Partition Power Control window or if the unit selected in the partition Configuration window is Free After checking perform the maintenance operation again Corrective action Confirm the maintenance unit and execute the operation again Severity Warning E 00069 Can t control system power under maintenance Release maintenance mode Meaning The system power cannot be operated during maintenance Corrective action Execute the operation after completion of the maintenance Severity Error E 00075 Partition aa cannot execute sadump Meaning sadump cannot be executed in Partition sadump startup has failed Corrective action Check if sadump is installed in the partition Severity Error E 00077 Partition aa cannot execute Power On Meaning Partition aa cannot be powered on Corrective action Check if the partition configuration is correct Severity Error E 00078 Partition aa cannot execute Power Off Meaning Partition aa cannot be powered off Corrective action Check the partition status Severity Error E 00079 Partition aa command failed Meaning Setting the power control command for Partition aa has failed Corrective action Check the partition status Severity Error 157 CA92344 0540 05 MMB Messages E 00080 Partition aa cannot execute Power Cycle Meaning Power Cycle cannot be executed for Partition aa Corrective action Check the par
263. tition status Severity Error E 00081 Partition aa cannot execute Reset Meaning Partition aa cannot be reset Corrective action Check the partition status Severity Error E 00082 Partition aa cannot execute INIT Meaning INIT cannot be executed for Partition aa Corrective action Check the partition status Severity Error E 00084 Partition aa cannot execute Force Power Off Meaning Force Power Off cannot be executed for Partition aa Displayed when the execution of Force Power Off has failed Corrective action Check the partition status Severity Error E 00087 PCI Address Mode setting failed Meaning PCI Address Mode setting has failed Corrective action Check the partition status Severity Error E 00089 Mirror Mode setting failed Meaning Mirror Mode setting has failed Corrective action Check the partition status Severity Error E 00091 Force Power Off Delay setting failed Meaning Setting the Force Power Off Delay in the Setup information has failed Corrective action Check the partition status Severity Error 158 CA92344 0540 05 MMB Messages 00095 The standby MMB is rebooting now Please wait several minutes Meaning Standby MMB has started rebooting Wait until the Standby MMB is ready Displayed when reboot is started from the Standby MMB reset instruction Corrective action No action is necessary Severity Info E 000
264. ttention Please do not operate the system with the cover removed In that case the operation of FAN is not guaranteed Severity Warning C9A10F2X Redundant fan n failed PCIBox n Slot n Port n Cascade s Meaning The FAN broke down X is the broke down FAN number s is disk enclosure model name Corrective action The FAN is mounted in the PSU and exchange the PSU ahead of time though the exchange of FAN is necessary Attention Please do not operate the system with the cover removed In that case the operation of FAN is not guaranteed Severity Warning C9A10F30 Temperature has reached the warning level PCIBox n Slot n Port n Cascade s Meaning A temperature rise warning was detected s is disk enclosure model name Corrective action Confirm the state of FAN Moreover lower the ambient temperature Attention Please do not operate the system with the cover removed In that case the operation of FAN is not guaranteed Severity Warning 69 CA92344 0540 05 MMB Messages C9A10F40 Temperature has reached the critical level PCIBox n Slot n Port n Cascade s Meaning A temperature rise critical was detected s is disk enclosure model name Corrective action Confirm the ambient temperature if it is unquestionable confirm FAN operates normally Attention Please do not operate the system with the cover removed In that case the operation of FAN is not guaranteed Severity W
265. ue the process according to the display in the window Severity Info E 00419 Unable to register the specified SB s as a Reserved SB due to unsupported CPU configuration Meaning The specified SB cannot be registered as a Reserved SB because the CPU does not meet the mounting criteria Corrective action Check the status of the CPU mounted on the SB Severity Error E 00420 Unable to register the specified SB s as a Reserved SB because the DIMM does not satisfy requirements of Mirror Mode Meaning The specified SB cannot be registered as a Reserved SB since the DIMM does not meet the requirements of the Mirror Mode Corrective action Check the status of the DIMM mounted on the SB Severity Error 177 CA92344 0540 05 MMB Messages W_00421 No change Meaning The processing is not selected Corrective action Select the operation to be executed Severity Warning E 00422 Unable to power on the Partition d due to CPU composition abnormal Meaning The specified partition cannot be powered on as there is an error in the CPU configuration Corrective action Set the number of CPUs mounted on the SB configuring the partition to at least two Severity Error W_00423 The partition home cannot be changed while the partition is running Please try to change the partition home after the partition is shutdown Meaning The partition Home cannot be changed while the partition is running Perform the
266. ve occurred frequently and have reached the replacement threshold Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Warning 15070202 CPLD access failure Meaning There is a possible CPLD failure Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070204 EEPROM access failure Meaning There is a possible EEPROM failure Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070209 Firmware error Meaning The firmware may be corrupted Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 1507020A Chassis Information mismatch Meaning There is mismatch of cabinet information Corrective action An MMB must be replaced If the problem persists the OPL must be replaced Severity Error 1507020B MMB reboot panic Meaning MMB panic reboot was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 12 CA92344 0540 05 MMB Messages 1507020E Configuration Data error MMB Meaning The configuration data may be corrupted Corrective action An MMB must be replaced If the problem persists another MMB must be replaced Severity Error Remarks This error is basic
267. ve of SB lt x gt exited This indicates success of SB hot remove dr util INFO 840 Add IOU lt x gt Meaning IOU x will be added This indicates that OS will add OU lt x gt 206 CA92344 0540 05 Dynamic Reconfiguration Messages dr util INFO d Execute lt x gt user programs at lt y gt timing d 841 842 Meaning lt x gt of collaboration programs will be executed at lt z gt timing lt z gt represents before or after dr util INFO 843 Executed user programs at x timing Meaning Collaboration programs executed at x timing x represents before or after dr util INFO 844 Added lOU lt x gt Meaning The addition of IOU lt x gt exited This indicates success of IOU hot add dr util INFO 850 Remove IOU lt x gt Meaning IOU x will be removed This indicates that OS will remove lOU lt x gt dr util INFO d Execute x user programs at y timing d 851 852 Meaning Collaboration programs executed at x timing x represents before or after dr util INFO 853 Executed user programs at x timing Meaning Collaboration programs executed at x timing x represents before or after dr util INFO 854 Removed IOU x Meaning The remove of IOU x exited This indicates success of IOU hot remove dr util INFO 860 Add PCle lt x gt Meaning PCle lt x gt will be added This indicates that OS will add PCle lt x gt dr util INFO
268. ve or a field engineer Severity Error 15070293 Diag RTC Time Operation Error Meaning An error was detected in the internal clock Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 15070299 Diag HUB Register Error Meaning A HUB error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 1507029A Diag UART Loopback Error Meaning The looped back data could not be received correctly Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 1507029B Diag NIC Loopback Timeout Meaning Time out has occurred in loop back Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150702A3 Diag RTC Low Battery Error Meaning An internal clock battery error was detected Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 150702AA Diag UART Timeout Meaning A loop back send or receive time out has occurred Corrective action An MMB must be replaced Contact your sales representative or a field engineer Severity Error 14 CA92344 0540 05 MMB Messages 150702AB Diag NIC Device Not Found Meaning NIC Device could not be found Corrective action An MM
269. verity Error Unable to force power off on the Partition d Meaning Partition x cannot be forcibly powered Off Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error Command Failed Code 0xaaaa Oxbb Meaning The power control command has failed aaaa Exception code bb Action code Corrective action Try setting again If it fails contact your sales representative or a field engineer Severity Error 128 CA92344 0540 05 MMB Messages Unable to power off the Partition n because you have not authority to operate this partition Meaning The Partition Operator has issued a power Off instruction for a partition that is not within the scope of management Power Off of Partition n is suppressed This error message is displayed only for Partition Operators Corrective action Confirm the processing target partition Severity Warning Unable to power off the partition s because the partition which does not have authority to you is included in the specified parameter Meaning The Partition Operator has issued a power Off instruction to a partition that is not within the scope of management Power Off is suppressed for all the specified partitions This error message is displayed only for Partition Operators Corrective action Check the command parameter and the processing target partition Severity Warning Unable to power on the Partit
270. verity Warning 11821 Adapter error The EEPROM Checksum Is Not Valid Meaning An EEPROM checksum error was detected Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 80 CA92344 0540 05 MMB Messages 11823 Adapter error setup link failed Meaning The setting of NIC speed failed A hardware error occurred Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11824 Adapter error pattern test failed Meaning The pattern test of the NIC failed A hardware error occurred Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11825 Adapter error set check reg test failed Meaning The register test of the NIC failed A hardware error occurred Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11826 Adapter error failed STATUS register test Meaning The STATUS register test of the NIC failed A hardware error occurred Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11827 Adapter error Could not enable Tx Queue Meaning The transmit queue cannot be enabled Corrective action High probability of an adapter failure Proceed to adapter replacement Severity Warning 11830 Adapter error Error
271. verity Error C5A10311 MMB 1 Firmware Update Failed Meaning Rebooting after updating the MMB 1 firmware update has failed and booting was done in the old version Corrective action MMB must be replaced Severity Error C5A10320 MMB 0 Firmware Update Failed write error Meaning NAND NOR reading has failed during the MMB 0 firmware update Corrective action MMB must be replaced Severity Error C5A10321 MMB 1 Firmware Update Failed write error Meaning NAND NOR writing has failed during the MMB 1 firmware update Corrective action MMB must be replaced Severity Error C5A10360 MMBZO0 Firmware Update Failed NOR bank change error Meaning Switching of NOR bank has failed during the MMB O firmware update Corrective action MMB must be replaced Severity Error 49 CA92344 0540 05 MMB Messages 2 1 15 C5A10361 MMB 1 Firmware Update Failed NOR bank change error Meaning Switching of NOR bank has failed during the MMB 1 firmware update Corrective action MMB must be replaced Severity Error C5A104FF Switch Over Failed Meaning MMB Active Standby switching has failed Corrective action MMB must be replaced Severity Error C5A32XYZ SB X was replaced with Reserved SB SB Y in Partition Z Meaning A faulty SB X was switched with Reserved SB Y in Partition Z Corrective action No action is necessary Severity Info C5A33X0Y Reserved SB X was removed f
272. view is also necessary Product and service inquiries For all product use and technical inquiries contact the distributor where you purchased your product or a Fujitsu sales representative or systems engineer SE If you do not know the appropriate contact address for inquiries about the PRIMEQUEST 2000 series use the Fujitsu contact line Fujitsu contact line We accept Web inquiries For details visit our website httos Awww s fujitsu com global contact computing PRMQST_feedback html Warranty If a component failure occurs during the warranty period we will repair it free of charge in accordance with the terms of the warranty agreement For details see the warranty Before requesting a repair If a problem occurs with the product confirm the problem by referring to 12 2 Troubleshooting in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537EN If the error recurs contact your sales representative or a field engineer Confirm the model name and serial number shown on the label affixed to the right front of the device and report it Also check any other required items beforehand according to 12 2 Troubleshooting in the PRIMEQUEST 2000 Series Administration Manual CA92344 0537EN The system settings saved by the customer will be used during maintenance vii CA92344 0540 05 Overview of Messages Manual How to use this manual This manual contains important information about the safe use of this product Read the manual tho
273. wever if other messages are displayed check the corresponding corrective action Severity Warning 7 CA92344 0540 05 MMB Messages 2 1 4 040B05FF Non redundant Insufficient Resource Meaning FAN is non redundant and the fans that are mounted are not sufficient for continuing the system operation Corrective action If the FANs basically not adequate increase the number of FANs And if the number of FANs had been reduced due to FAN failure see the FAN failure message and replace the faulty fan Severity Error PSU and DDC related PSU and DDC related messages are listed below O86FOOFF Present Meaning PSU is mounted Corrective action No action is necessary Severity Info 086F01FF Power Supply Failure detected Meaning Failure was detected in the power unit Corrective action Replace the target PSU or IO PSU Severity Error 086F0202 Power Supply output over current critical Meaning Output over current error has occurred Corrective action Replace the target PSU Severity Warning 086F0203 Power Supply output over current warning Meaning Output over current warning has occurred Corrective action Replace the target PSU Severity Warning 086F0204 Power Supply input over voltage critical Meaning Input over voltage error has occurred Corrective action Replace the target PSU Severity Warning CA92344 0540 05 MMB Messages 086F0205 Power Sup
274. with CLI Corrective action Make two special accounts For the detail of making of the special account refer to 2 2 78 set special account in the PRIMEQUEST 2000 series Operations Management Tool Reference CA92344 0539 Severity Warning W 00618 LDAP cannot be enabled because LDAP User Group of the Admin privilege is not set Meaning LDAP cannot be enabled because LDAP User Group of the Admin privilege is not set Corrective action Make LDAP User Group with privilege of Administrator For the detail of making of the LDAP User Group refer to 1 4 4 2 LDAP User Group List window in the PRIMEQUEST 2000 series Operations Management Tool Reference CA92344 0539 Severity Warning 196 CA92344 0540 05 MMB Messages 00619 The Test LDAP succeeded Meaning Test of LDAP connection is succeeded Corrective action No action is necessary Severity Info 197 CA92344 0540 05 Dynamic Reconfiguration Messages 3 1 3 2 CHAPTER 3 Dynamic Reconfiguration Messages This section lists the DR messages and contains information on how to respond to them Messages concerning incomplete system environment dr util ERR 101 No space left on device Meaning There s no disk free space Corrective action Failed to gather information because the disk free space is insufficient Please execute the command again after securing the disk free space dr util ERR d s d 102 103 Meaning Error 96s
275. x Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC504160 PCI Uncorrectable Internal Error Bus Device 0x Function Ox Meaning An internal error was detected in the PCI express Device Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC504170 PCI MC Blocked TLP Bus Device 0x Function Ox Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC504180 PCI AtomicOp Egress Blocked Bus Device 0x Function Ox Meaning An error was detected in the PCI express packet Corrective action Referring the Source and Unit of the MMB system event log replace the unit according Replacement Component Type A in the TABLE A 1 Replacement component list 1 Severity Error BC504190 PCI TLP Prefix Blocked Error Bus Device 0x Function Ox Meaning An error was detected in the PCI express packet Corrective
276. x Function 0x Message ID Meaning A warning was detected by PCI driver Corrective action After checking Message ID in the SEL message refer to 2 2 List of SVAS messages to take appropriate action Severity Warning BC549000 Driver Monitor Error Segment Bus Device 0x Function 0x Message ID Meaning An error was detected by PCI driver Corrective action After checking Message ID in the SEL message refer to 2 2 List of SVAS messages to take appropriate action Severity Error 45 CA92344 0540 05 MMB Messages OS related BMC BDC Operating system boot Meaning OS has booted Corrective action No action is necessary Severity Info BDD Operating system shutdown Meaning The operating system has shut down The output in the wildcard may not correspond to the specified reason or comment And a large number of messages may be output It is not an error if a large number of these messages are displayed when using the SVIM If this occurrence of a large numbers is to be suppressed in other situations refer the Microsoft technical information KB 962920 http support microsoft com kb 962920 en us Corrective action No action is necessary Severity Info BDE Operating system BugCheck Meaning An error has occurred in the operating system Corrective action The software needs to be examined Severity Warning 2 1 13
277. y Corrective action No action is necessary Severity Info Unable to execute this command on a standby MMB Meaning This command cannot be executed on a Standby MMB Corrective action Confirm that the command was executed on an Active MMB Severity Warning The specified partition number is invalid Meaning The partition number is invalid Corrective action Confirm that the specified partition number is correct Severity Warning 125 CA92344 0540 05 MMB Messages The specified SB IOU Extended Partitioning number is invalid Meaning SB lOU Extended Partitioning number is invalid In the execution of the set partition home command only the SB pattern emerges Corrective action Confirm that the specified SB IOU Extended Partitioning number is correct Severity Warning The specified SB x IOUZx is Not present Meaning The specified SB IOU has not been mounted In execution of the set partition home command only the SB pattern emerges Corrective action Confirm that the SB IOU is correctly specified and that the specified SB IOU has been mounted Severity Warning The specified SB x IOUZx Extended Partitioning x is not free Meaning The specified SB IOU or Extended Partitioning is already incorporated into the partition Corrective action Confirm that the SB IOU Extended Partitioning is correctly specified Also confirm the configuration of the
278. y Severity Info 75 CA92344 0540 05 MMB Messages E76F0903 SSD Rated Write Endurance has reached 50 Meaning SSD Rated Write Endurance has reached 50 Corrective action Please confirm the usage condition of SSD and prepare the replacement part of SSD if necessary Severity Info E76F0904 SSD Rated Write Endurance has reached 70 PCI Box or l OU n Slot n Port n Cascade 96s s Disk enclosure model name e g JX40 Meaning SSD Rated Write Endurance has reached 70 Corrective action Please confirm the usage condition of SSD and prepare the replacement part of SSD if necessary Severity Info E76F0905 SSD Rated Write Endurance has reached 70 Meaning SSD Rated Write Endurance has reached 70 Corrective action Please confirm the usage condition of SSD and prepare the replacement part of SSD if necessary Severity Info E76F0906 SSD Rated Write Endurance has reached 80 PCI Box or IOUZin Slotzn Port n Cascade s s Disk enclosure model name e g JX40 Meaning SSD Rated Write Endurance has reached 80 Corrective action Please prepare the replacement part of SSD Severity Info E76F0907 SSD Rated Write Endurance has reached 80 Meaning SSD Rated Write Endurance has reached 80 Corrective action Please prepare the replacement part of SSD Severity Info E76F0908 SSD Rated Write Endurance has reached 90 PCI Box or lOU n Slot n Port n Cascade s
279. your sales representative or a field engineer Severity Warning 13195 Adapter error IOC Not operational Meaning The adapter is not in the operational state Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13196 Adapter error Issuing HardReset Meaning The hardware will be reset Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13198 Adapter error Not Ready Meaning The adapter does not become READY Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13203 Adapter error IOC Not Active Meaning The adapter is not operating The message frame acquisition function returned NULL Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning 13211 Adapter error IOC is non operational Meaning The adapter cannot be used Corrective action Replace the target device If the error keeps recurring contact your sales representative or a field engineer Severity Warning 98 CA92344 0540 05 MMB Messages 13212 Adapter error Running mpt_dead_ioc thread failed Meaning Hardware failure Adapter delet