Home

650 Watt - Saskbattery.com

image

Contents

1. SUNFDRCE PRO SERIES 650 Watt PURE SINE WAVE INVERTER ONDULEUR ONDE SINUSO DALE PURE User s Manual Notice D utilisation The Pure Sine Wave Inverter has been carefully engineered and manufactured for dependable operation Please read this manual thoroughly before operating your new inverter The manual contains information necessary to become familiar with the features and obtain the performance that will bring you continued enjoyment for many years Please keep this manual on file for future reference About the Pure Sine Wave Inverter Pure Sine Wave Inverters convert low voltage direct current DC to 120 volts V alternating household current AC depending on the model and its rated capacity Pure Sine Wave Inverters draw power either from standard 12 V automobile and marine batteries or from portable high power 12 V sources Controls and components Front Panel 1 ON OFF Power Switch 2 LED Status Indicator Bar 3 110 V AC Outlets x 2 Rear Panel 4 Power Input Terminal Red Positive 5 Power Input Terminal Black Negative 6 Cooling Fan 7 Chassis Ground 2 0 0 ue 1 LJ 3 e 0 0 alaliik tJ o 40 7 6 5 CAUTION Before installing and using the Pure Sine Wave Inverter read all instructions and cautionary markings on the inverter and batteries This inverter is designed to operate using a 12 volt power source only The unit will not operate from a 6 volt battery or a
2. Changez la position de onduleur des cables de l antenne et du cordon d alimentation de la t l vision 3 Isolez la t l vision son cordon d alimentation et les cables de antenne de la source d alimentation de 12 volts CC en utilisant une rallonge entre onduleur et la t l vision 4 Enroulez le cordon d alimentation de la t l vision et les cables d entr e raccordant la source d alimentation de 12 volts CC l onduleur 5 Installez un filtre antiparasite CA ou un produit similaire entre l onduleur et le cordon d alimentation de la t l vision Ces filtres sont disponibles chez la plupart des fournisseurs de mat riel lectronique Note Les chaines audio bon march peuvent mettre un bourdonnement lorsqu elles sont aliment es a partir d un onduleur Ceci r sulte des filtres inad quats de la cha ne audio Il n existe pas de solution a ce probleme DANGER e Ne tentez jamais de faire fonctionner l Onduleur Onde Sinusoidale Pure partir de sources d alimentation autres qu une batterie de 12 volts e D branchez toujours l onduleur s il n est pas utilis Branchez toujours l onduleur la masse avant de le mettre en fonction e Assurez vous que les connexions aux bornes du cable d alimentation demeurent parall les n gatif au n gatif et positif au positif Les connexions d alimentation onduleur doivent tre comme suit positif au positif et n gatif au n gatif Une pola
3. a DEL 3 Prises de 110 volts CA x 2 Panneau arri re 4 Borne d entr e de l alimentation Rouge Positif 5 Borne d entr e de l alimentation Noir N gatif 6 Ventilateur 7 Mise la masse du ch ssis DANGER Avant d installer et d utiliser Onduleur Onde Sinusoidale Pure veuillez lire attentivement toutes les instructions et les tiquettes d avertissement sur onduleur et sur les batteries Cet onduleur est con u pour fonctionner uniquement partir d une source d alimentation de volts L appareil ne fonctionnera pas partir de batteries de 6 volts ou de 24 volts Ne jamais tenter de raccorder l onduleur a une source autre qu une batterie ayant une tension de sortie nominale de 12 volts Suite a un tel raccordement l onduleur pourrait tre endommag et la garantie sera annul e La tension de 120 volts peut causer des dommages des blessures graves et m me la mort Une utilisation incorrecte de l onduleur peut causer des dommages la propri t des blessures corporelles et m me la mort Mise en op ration Lorsque vous commutez en circuit ON MARCHE un appareil ou un outil qui utilise un moteur ou une lampe une t l vision par exemple une pointe de courant initiale est requise pour le d marrage Cette pointe de courant est identifi e comme le courant de d marrage ou la charge de pointe Une fois d marr l appareil ou l outil n cessite moins de courant pour continuer fonction
4. de la batterie peut tre Rechargez ou remplacez la batterie Peut basse tre n cessaire d utiliser deux batteries pour alimenter certains appareils Contacts l ches causent une chute de tension D branchement et rebranchement des connexions peuvent tre requis Peut tre Utilisation d un voltmetre du mauvais n cessaire d utiliser des c bles plus gros type pour v rifier la tension de sortie jou plus courts V rifiez la condition de la fiche et de la prise de 12 volts Nettoyez ou remplacez au besoin Tension CA de sortie basse ou absente Utilisez un voltm tre tension efficace RMS Tension de la batterie sous 10 volts Rechargez ou remplacez la batterie Consommation CA de l appareil Utilisez un onduleur de plus haute DEL Fault Panne allum e exc de la capacit de onduleur capacit ou un appareil consommant moins Onduleur en surchauffe causant une surcharge thermique Arr tez l onduleur et laissez le refroidir Onduleur peut tre d fectueux Assurez une ventilation ad quate Contactez l assistance technique t l phonique Interf rence dans les signaux de t l vision Interf rence lectrique caus e par onduleur Signal de la t l vision trop faible Utilisez un filtre sur le cordon d alimentation de la t l vision D placez la t l vision Essayez une autre t l vision Diff rentes marques ou mod les peuvent op rer diff remment face l interf
5. rence Accessoire ne fonctionne pas Impossible de d marrer laccessoire Comm utez l onduleur ON MARCHE OFF ARRET et ON MARCHE de nouveau Contactez le fabricant de l appareil pour v rifier la consommation de pointe et si le produit est compatible avec un onduleur onde sinuso dale pure Alarme de batterie basse active de fa on continue Tension d entr e sous 10 5 0 5 VCC Mauvais contacts causant une chute de tension Rechargez ou remplacez la batterie Des batteries additionnelles peuvent tre requises pour alimenter certains accessoires D branchez et rebranchez les connexions Peut tre n cessaire d utiliser des c bles plus gros ou plus courts V rifiez la fiche et la prise de 12 volts Nettoyez ou remplacez au besoin GARANTIE LIMIT E Ce produit est couvert par une garantie limit e de deux ans Sunforce Products Inc garantit l acheteur initial que ce produit sera op rationnel et libre de d faut de mat riaux ou de main d ceuvre pendant une p riode de deux ans d butant a la date de lachat Pour obtenir les services de garantie veuillez contacter Sunforce Products pour des directives additionnelles au 1 888 478 6435 ou par courrier lectronique info sunforceproducts com Une preuve d achat incluant la date d achat et une explication de la r clamation sont requises pour obtenir les services de garantie Les batteries au ferro nic
6. the television set 4 Coil the television power cord and the input cables running from the 12 volt power source to the inverter 5 Attach an AC interference filter or similar product between the inverter and the television power cord These filters are available at most electronic supply stores Note Inexpensive sound systems may emit a buzzing sound when operated with an inverter This is due to the inadequate filters in the sound system There is no solution to this problem WARNING e Never attempt to operate the Pure Sine Wave Inverter from any power source other than a 12 volt battery e Always disconnect the inverter when not in use Always ground the inverter before operating e Always ensure the power cable terminal connections run in parallel Negative to Negative and Positive to Positive Reverse polarity DC power connections to the inverter must be positive to positive and negative to negative A reverse polarity connection positive to negative will blow a fuse in the inverter and may permanently damage the inverter The fuse is not user replaceable and you will void the warranty Check these connections frequently to make sure they remain secure Loose connections cause excessive voltage drop and may cause overheated wires and melted insulationUse the heaviest gauge wire available to connect the inverter to the power source When setting up the inverter make certain that the inverter is positioned far away from a
7. une dizaine de minutes pour recharger la batterie e Lorsque l alarme audible se fait entendre de fa on continue ou qu un arr t automatique survient commutez imm diatement l onduleur hors circuit OFF ARRET Ne remettez pas onduleur en marche avant d avoir identifi et corrig le probl me e Pour viter la d charge de la batterie d branchez toujours onduleur lorsqu il n est pas utilis e N exposez pas l Onduleur Onde Sinusoidale Pure la pluie la neige les claboussures ou l eau de cale Pour r duire les risques d incendie vitez de couvrir ou d obstruer les ouvertures de ventilation N installez jamais l onduleur dans un compartiment trop petit sans jeu Des surchauffes peuvent survenir vitez de placer l onduleur pr s d une source de chaleur ou au grand soleil e Utilisez uniquement les accessoires recommand s par le fabricant Le manquement cette directive peut r sulter en des risques d incendie de chocs lectriques ou de blessures corporelles e Pour viter les risques d incendie et les chocs lectriques assurez vous que le c blage existant est en bonne condition et qu il n est pas trop petit N op rez pas l onduleur avec du c blage endommag ou de qualit inf rieure N op rez pas l onduleur s il a t chapp ou endommag de quelque fa on que ce soit e Ne d montez jamais l onduleur Non seulement vous annulerez la garantie mais vous vous exposerez des bless
8. 24 volt battery Do not attempt to connect the inverter to any other power source other than a battery with a nominal output voltage of 12 V or damage to the unit may occur and will void the warranty 120 V can inflict serious injury damage or death Improper use of the inverter may result in property damage personal injury or loss of life Getting Started When you turn on an appliance or a tool that operates using a motor or a tube such as a television it requires an initial surge of power to start up This surge of power is referred to as the starting load or peak load Once started the tool or appliance reguires less power to continue operation This is referred as the continuous load in terms of power reguirements You will need to determine how much power your tool or appliance reguires to start up the starting load Also you will need to know continued running power reguirements of the appliance continuous load Power consumption is rated in wattage watts or amperes amps and this information is usually stamped on most appliances and equipment If this information is not indicated on the appliance or equipment check the owner s manual or contact the manufacturer to determine if the device you are using is compatible with your Pure Sine Wave Inverter The output of a Pure Sine Wave Inverter provides stable power and it can be used to run the electronic eguipment that modified sine wave inverters cannot For example
9. a Pure Sine Wave Inverter works with mini electronic tools air pumps electronic doors mini motors refrigerators or hair dryers e Multiply Amps X 120 V AC Watts This formula yields a close approximation of the continuous load of your appliance e Multiply Watts X 2 Starting Load This formula yields a close approximation of the starting load of your appliance Most often the start up load ofthe appliance or power tool determines whether your inverter is correctly sized for the application Some appliances have starting loads up to 7X the continuous load If you are unsure whether the Pure Sine Wave Inverter will operate a particular piece of eguipment or appliance run a test All Pure Sine Wave Inverter are designed to automatically shut down in the event of a power overload This protection feature prevents damage to the unit while testing appliances and equipment with ratings in the 650 W range If an appliance in the 650 W range will not operate properly when first connected to the Inverter turn the Inverter rocker switch ON 1 OFF O and ON 1 again in quick succession If this procedure is not successful it is likely that the Pure Sine Wave Inverter does not have the required capacity to operate the appliance in question Connecting Your Inverter to the 12 V Power Source When connecting the inverter to the power source it is recommended that the thickest wire available be used in the shortest length possible Distance
10. ent raccord la masse Branchement de l onduleur votre appareil de 110 volts CA 1 Commutez l onduleur en circuit ON MARCHE Le panneau d etat DEL s illuminera en vert pour confirmer que l alimentation est appliqu e l onduleur 2 Commutez l onduleur hors circuit OFF ARRET L indicateur d etat DEL peut clignoter bri vement Ceci est normal L alarme audible interne peut aussi g n rer un court bip Ceci est aussi normal 3 Assurez vous que l appareil tre aliment est commut hors circuit OFF ARRET Branchez l appareil l une des deux sorties de 120 volts CA du panneau avant de onduleur 4 Commutez l onduleur en circuit ON MARCHE 5 Commutez l appareil en circuit ON MARCHE NOTE L alarme audible peut g n rer un bip momentan lorsque l onduleur est commute hors circuit OFF ARR T O Cette m me alarme peut aussi se faire entendre lorsque l onduleur est raccord ou d branch de la source d alimentation de 12 volts Lorsque vous utilisez une rallonge entre onduleur et l appareil cette rallonge ne devrait pas exc der 50 pieds 15 2 m tres cette distance il ne devrait pas exister de chute de tension mesurable dans l alimentation provenant de l onduleur Source d alimentation de 12 volts La plupart des batteries de 12 volts pour v hicules et bateaux peuvent alimenter amplement l onduleur pendant 30 60 minutes m me si le mo
11. esult of current flowing to charge capacitors within the inverter This is a normal occurrence Due tothe possibility of sparking however it is extremely important that both the inverter and the 12 volt battery be positioned far from any possible source of flammable fumes or gases CAUTION Failure to heed this warning could result in fire or explosion Locate the Chassis Ground at the rear of the inverter Run a wire from this terminal to a proper grounding point using the shortest practical length of 8 AWG wire You can connect this wire to the chassis of your vehicle or to the grounding system in your boat When in remote locations the ground wire can be connected to the earth one way to accomplish this is to attach it to a metal rod driven into the earth ground Before connecting the ground make certain that the inverter is turned off Operating the inverter without correctly grounding the unit may result in electrical shock Connecting Your Inverter to the 110 Volt Appliance 1 Turn ON 1 the Inverter The LED Status Indicator Bar will illuminate to confirm that power is running to the inverter 2 Turn OFF O the Inverter The LED Status Panel may briefly blink This is normal The internal audible alarm may also sound a short chirp This is also normal 3 Ensure the appliance to be operated is turned off plug the appliance into one of the two 120 V AC Outlets on the front panel ofthe inverter 4 Turn the inverter on 5 Turn the ap
12. from Battery lt 4 gt 1 2m 4 6 1 2 2m gt 6 gt 2m Wire Size 4 AWG 2AWG 0 or 00 AWG Use of 0 gauge wire to make the connections to the inverter may require a 0 to 4 Gauge Adapter This adapter is available through most electrical supply stores 1 Make sure the ON OFF Switch located on the front panel of the inverter is in the OFF O position 2 Unscrew the red and black caps from the power input terminals located on the rear of the inverter 3 Connect the wires to the power input terminals at the rear of the inverter Make sure to match the negative BLACK terminal on the inverter with the wire that connects to the negative terminal on the 12 volt power source Then repeat this procedure with the positive RED terminal connecting a wire to the positive terminal of the 12 volt power source Make sure you have good secure connections but do not over tighten these screws Important Information before use Loose connections can result in a severe decrease in voltage which may cause damage to the wires and insulation WARNING REVERSE POLARITY WILL DAMAGE UNIT Failure to make a proper connection between the inverter and the power source will result in reverse polarity Reverse polarity will blow the internal fuses in the inverter and may cause permanent damage to the inverter Damage caused by reverse polarity is not covered under the warranty Making the connection between the Positive Terminals may cause a spark as a r
13. hooting Problem Reason Solution Poor contact with battery terminals Check connections between inverter and power Source Poor battery condition tighten or repair as needed PONOT NSORO SIS Incorrectly testing output voltage Recharge or replace power source as needed Battery voltage below 10 V Recharge or replace power source as needed Red LED Indicator On Equipment being run has a higher draw than inverter is capable Reduce load on the inverter or use a higher capacity inverter Inverter is too hot Allow inverter to cool Ensure adeguate ventilation and or reduce load on inverter Draw may be too high Turn inverter OFF then ON a couple times to reset TV Will Not Work Refer to TV specifications for start up voltage and or compatibility with Mobile Power Inverter or a larger capacity inverter may be reguired Electrical interference from the Add a Ferrite Data Line filter to TV Power TV Interference inverter Cord Low Battery Alarm on Input voltage is below 10 V Ensure and keep voltage above 10 V Constantly Poor or weak battery condition Recharge or replace power source as needed Inadequate power supply to inverter or excessive voltage drop Use a lower gauge wire and keep distance between inverter and power source as short as possible LIMITED WARRANTY This product is covered by a two year limited warranty Sunforce Products Inc warrants to the original purchaser that this produc
14. kel ne fonctionnent pas avec cet onduleur
15. ner Cette condition est identifi e comme la charge continue en ce qui a trait la puissance requise Vous devrez d terminer combien de puissance votre appareil ou votre outil exige au d marrage courant de d marrage Vous devrez aussi d terminer la puissance requise pour le fonctionnement continu de l appareil une fois qu il est d marr charge continue La consommation lectrique est tablie en watts ou en amp res Cette information est g n ralement marqu e sur les appareils ou l quipement Si cette information n est pas indiqu e sur l appareil ou l quipement consultez le manuel de l utilisateur ou contactez le fabricant pour d terminer si l appareil que vous utilisez est compatible avec votre Onduleur Onde Sinuso dale Pure e La sortie de I Onduleur Onde Sinuso dale Pure est une source d alimentation stabilis e qui peut tre utilis e pour alimenter l quipement lectronique qui ne peut pas s alimenter a partir d onduleurs ondes sinuso dales modifi es e Par exemple un Onduleur a Onde Sinusoidale Pure fonctionne avec les outils lectroniques de petit format par exemple les pompes air les portes lectroniques les petits moteurs les r frig rateurs ou les s choirs cheveux e Calculez A amp res x 120 V CA W watts Cette formule fournit une bonne approximation de la charge continue de votre appareil e Calculez W watts x 2 Charge de d marrage Cette formule fournit
16. njury to persons e To avoid a risk of fire and electric shock make sure that existing wiring is in good condition and that it is not undersized Do not operate the inverter with damaged or substandard wiring Do not operate the inverter if it has been dropped or damaged in any way e Do not disassemble the inverter not only will you void the warranty but you may risk personal injury from electrical shock or fire Internal capacitors remain charged after all power is disconnected e To reduce risk of injury disconnect both AC and DC power from the inverter before attempting any maintenance or cleaning Turning off controls will not reduce this risk Do not over tighten the nut on the DC input terminals Damage to the DC input terminals may result e Terminal posts at the rear get hot and burn skin use caution when removing wires after a large load has been applied Specifications OUTPUT POWER Continuous 650 W Surge power 1200 W BATTERY DC INPUT 12 V DC system 12 V DC nominal 11 15 V operative INVERTER AC OUTPUT Voltage 110 VRMS AC 10 Freguency 60 Hz 2 Hz Wave form Pure Regulation Pure Sine Wave Efficiency 90 PROTECTIONS Reduced voltage starter Yes Low battery shutdown Yes DC Input overload voltage Yes Output overloads yes Overload temperature Yes Short circuit shutdown Yes PHYSICAL Ventilation High Speed Cooling Fan Weight 8 22 Ibs 3 73 kg 4 4 kg Dimensions 12 99 x 9 06 x 3 54 33 x 23 x 9 cm Trouble S
17. ny potential source of flammable fumes or gases While in use make sure the inverter is properly ventilated Do not operate the inverter near flammable materials fumes or gases e Make certain the power consumption of the appliance or equipment you wish to operate is compatible with the capacity of the inverter Do not exceed 650 W When attempting to operate battery chargers monitor the temperature of the battery charger for approximately 10 minutes If the battery charger becomes abnormally warm disconnect it from the inverter immediately e When operating the inverter with a Deep Cycle battery from a vehicle with it s engine off start the engine every 30 to 60 minutes and let it run for approximately 10 minutes to recharge the battery e In the event of a continuous audible alarm or automatic shutdown turn the Inverter OFF immediately Do not restart the inverter until the source of the problem has been identified and corrected e To avoid battery drain always disconnect the inverter when not in use Do not expose the Pure Sine Wave Inverter to rain snow spray or bilge water To reduce risk of a fire hazard do not cover or obstruct the ventilation openings Do not install the inverter in a zero clearance compartment Overheating may result e Avoid placing the inverter near sources of heat or in direct sunlight e Use only attachments recommended by the manufacturer Doing otherwise may result in a risk of fire electric shock or i
18. pliance on NOTE The audible alarm may make a momentary chirp when the inverter is turned OFF O This same alarm may also sound when the inverter is being connected to or disconnected from the 12 volt power source When using an extension cord from the inverters to the appliance the extension cord should be no more than 50 feet long At this length there should be no measurable decrease in power from the inverter 12 Volt Power Source Most 12 volt automobile and marine batteries will provide an ample power supply to the inverter for 30 to 60 minutes even when the engine is turned off Actual time may vary depending on the age and condition of the battery and the power demand being placed on it by the equipment being operated If you decide to use the inverter while the engine is off we recommend that you start the engine every 30 to 60 minutes and let it run for approximately 10 minutes to recharge the battery Itis recommended that any device plugged into the inverter be turned OFF before starting the vehicle engine It is not necessary to disconnect the inverter when starting the vehicle engine the inverter may momentarily cease operation as the battery voltage decreases When the inverter is not supplying power it draws very low amperage from the battery It is recommended that the inverter always be disconnected when not in use Safety and Usage Precautions 1 For best operating results place the inverter on a flat surface 2 Keep in
19. r sur o pr s des bouches de chaleur des radiateurs ou d autres sources de chaleur Ne placez pas ou n utilisez pas l onduleur en plein soleil Les temp ratures ambiantes id ales se situent entre 50 et 80 F 10 et 26 C 5 Pour dissiper correctement la chaleur g n r e par l onduleur lorsque celui ci fonctionne assurez une ventilation ad quate l onduleur Maintenir les abords de l onduleur propres lorsque celui ci fonctionne 6 N utilisez pas onduleur pr s de mat riaux inflammables Ne placez pas l onduleur dans des endroits comme les compartiments batteries o les vapeurs et les gaz peuvent s accumuler Caract ristiques de s curit de l onduleur 1 Protection contre les courts circuits L onduleur s arr tera automatiquement jusqu ce que le court circuit soit limin 2 Alarme de basse tension Une alarme sera d clench e lorsque la tension de la batterie s abaisse 10 5 0 5 volts CC Ceci est une indication que la batterie doit tre recharg e 3 Protection contre les surtensions L onduleur s arr te automatiquement si la tension d entr e exc de 16 5 1 0 volts CC 4 Protection contre les sous tensions L onduleur s arr te automatiquement si la tension d entr e est inf rieure 10 0 0 5 volts CC 5 Protection contre les surcharges L onduleur s arr te automatiquement si la charge continue de l appareil aliment exc de 650 watts ou si la charge de pointe de appareil e
20. rit invers e positif au n gatif et n gatif au positif grillera le fusible interne de l onduleur et peut aussi causer des dommages permanents Le fusible ne doit pas tre remplac par l utilisateur puisque cette action annulera la garantie V rifiez fr quemment ces connexions pour vous assurer qu elles demeurent s curitaires Les connexions laches causent des chutes de tension excessives et peuvent causer la surchauffe des fils et fondre l isolation Utilisez le fil du plus gros calibre disponible pour raccorder l onduleur la source d alimentation Lorsque vous installez onduleur assurez vous qu il est loign de toute source possible de vapeurs ou de gaz inflammables Pendant le fonctionnement assurez vous que l onduleur est ventil ad quatement Ne faites pas fonctionner l onduleur pr s de mat riaux de vapeurs ou de gaz inflammables e Assurez vous que la consommation lectrique de l appareil ou de l quipement que vous voulez alimenter est compatible avec la capacit de l onduleur N exc dez pas 650 watts e Lorsque vous utilisez un chargeur de batteries surveillez en la temp rature pendant une dizaine de minutes Si le chargeur devient anormalement chaud d branchez le imm diatement de l onduleur e Lorsque vous alimentez l onduleur partir de la batterie d charge pouss e d un v hicule alors que le moteur ne tourne pas d marrez le moteur toutes les 30 60 minutes et laissez le tournez pendant
21. s e Une polarit invers e grillera le fusible interne et pourra causer des dommages permanents l onduleur Les dommages r sultant d une polarit invers e ne sont pas couverts par la garantie Lors de la connexion entre les bornes positives une tincelle peut se produire r sultant du courant requis pour charger les condensateurs l int rieur de l onduleur Ceci est une situation normale Cependant en raison de la possibilit de la g n ration d tincelles il est extr mement important que l onduleur et la batterie de 12 volts soient plac s le plus loin possible de toutes sources possibles de vapeurs ou de gaz inflammables DANGER Le manquement cet avertissement peut r sulter en un incendie ou une explosion Localisez la borne de masse du chassis l arri re de onduleur Raccordez un fil entre cette borne et un point de mise la terre s curitaire utilisant un fil de calibre 8 CAF le plus court possible Vous pouvez raccorder ce fil au ch ssis de votre v hicule ou au syst me de mise la masse de votre bateau Lorsque vous vous trouvez dans les endroits loign s le fil de la masse peut tre raccord directement la terre une fa on de r aliser ceci est de le raccorder une tige m tallique enfonc e dans le sol Avant de brancher la masse assurez vous que l onduleur est commut hors circuit OFF ARR T Des chocs lectriques peuvent r sulter si l onduleur est utilis sans qu il soit correctem
22. t is functional and free from defects in materials and workmanship for the period of two year from date of purchase To obtain warranty service please contact Sunforce Products for further instruction at 1 888 478 6435 or email info sunforceproducts com Proof of purchase including date and an explanation of complaint is required for warranty service Nickel iron batteries do not work with this inverter L Onduleur a Onde Sinusoidale Pure a t con u et fabriqu avec soin pour assurer un fonctionnement fiable pendant des ann es Veuillez lire attentivement ce manuel avant d utiliser votre nouvel onduleur pour la premi re fois Le manuel contient l information requise pour vous familiariser avec les caract ristiques de onduleur et obtenir la performance dont vous pourrez jouir pendant de nombreuses ann es Veuillez conserver ce manuel dans un endroit s r a titre d information Au sujet de l Onduleur a Onde Sinusoidale Pure Les Onduleur a Onde Sinusoidale Pure convertissent une basse tension de courant continu CC en tension alternative CA de 120 volts a tre utilis e a domicile Les caract ristiques varient selon les mod les et les capacit s nominales Les onduleurs s alimentent a partir de batteries ordinaires pour v hicules ou pour bateaux ou a partir de sources de haute puissance mobiles de 12 volts Commandes et composantes Panneau avant 1 Interrupteur de l alimentation ON OFF MARCHE ARRET 2 Indicateur d tat
23. teur ne tourne pas Le temps peut varier en fonction de l ge et de l tat de la batterie et de la demande d nergie plac e sur l onduleur par l quipement qui est alimente Si vous choisissez d utiliser onduleur alors que le moteur ne tourne pas nous vous recommandons de d marrer le moteur toutes les 30 60 minutes et de le laisser tourner environ 10 minutes pour recharger la batterie Nous recommandons que tout appareil branch l onduleur soit commut hors circuit OFF ARR T O avant de d marrer le moteur du v hicule Il n est pas n cessaire de d brancher onduleur lorsque vous d marrez le moteur du v hicule L onduleur peut interrompre momentan ment son fonctionnement lorsque la tension de la batterie s abaisse Lorsque l onduleur n alimente aucun appareil il tire tr s peu de courant de la batterie Cependant nous recommandons de toujours d brancher l onduleur lorsqu il n est pas utilis Pr cautions s curitaires lors de l utilisation 1 Pour assurer un fonctionnement maximal placez l onduleur sur une surface plane 2 Assurez vous de maintenir l onduleur au sec N exposez pas l onduleur l eau ou l humidit 3 NUTILISEZ PAS l onduleur si vous onduleur ou tout ce qui a t et sera en contact avec l onduleur tes tremp s L eau et les autres liquides sont conducteurs d lectricit ce qui peut causer des blessures graves et m me la mort 4 vitez de placer l onduleu
24. the equipment being operated exceeds 650 W or the surge draw of the equipment exceeds 1200 W 6 Thermal Protection The LED Status Panel will illuminate RED and the inverter will automatically turn itself off when the circuit temperature exceeds 150 F 7 Overheating Protection The inverter is equipped with a cooling fan which is designed to run continuously while the inverter is operating Automatic shut down of the unit caused by high circuit temperatures will occur when the cooling fan is unable to maintain a temperature safe for operation In the event of automatic shut down or a continuous audible alarm turn the inverter power switch to the OFF O position until the source of the problem has been determined and resolved Television and Audio Suggestions Although all Pure Sine Wave Inverters are shielded and filtered to minimize signal interference some interference with your television picture may be unavoidable especially with weak signals However here are some suggestions that may improve reception 1 Make sure the television antenna produces a clear signal under normal operation conditions plugged into a standard 110 volt AC outlet Also ensure that the antenna cable is properly shielded and or of good quality 2 Change the position of the inverter antenna cables and television power cord 3 Isolate the television its power cord and antenna cables from the 12 volt power source by running an extension cord from the inverter to
25. ue sa longueur soit minimale Distance de la batterie lt 4 gt 1 2 m 4 6 1 2 2m gt 6 gt 2m Calibre du fil 4CAF 2CAF 0 ou 00 AWG L utilisation du fil de calibre O pour r aliser le raccordement l onduleur peut n cessiter un adaptateur des calibres 0 4 Cet adaptateur est disponible chez la plupart des fournisseurs de mat riel lectrique 1 Assurez vous que l interrupteur ON OFF MARCHE ARR T situ sur le panneau avant de l onduleur se trouve la position OFF MARCHE 0 2 D vissez les boutons rouge et noir des bornes d entr e de l alimentation situ s l arri re de onduleur 3 Raccordez les fils aux bornes d entr e de l alimentation l arri re de londuleur Assurez vous que la borne n gative NOIRE de l onduleur correspond au fil qui raccorde la borne n gative de la source d alimentation de 12 volts Puis r p tez cette proc dure pour la borne positive ROUGE en raccordant un fil la borne positive de la source d alimentation de 12 volts Assurez vous que les connexions sont fermes sans toutefois trop serrer ces vis Information importante avant l utilisation Les connexions l ches peuvent causer des chutes de tension importantes pouvant occasionner des dommages aux fils et l isolation DANGER UNE POLARIT INVERS E ENDOMMAGERA L APPAREIL Le manquement r aliser une connexion correcte entre l onduleur et la source d alimentation r sultera en une polarit inver
26. une bonne approximation de la charge de d marrage de votre appareil La plupart du temps la charge de d marrage de l appareil ou de l outil lectrique d termine si oui ou non le calibre de votre onduleur est suffisant pour votre application Certains appareils ont des charges de d marrage allant jusqu sept fois 7x la charge continue Si vous avez des doutes sur la capacit de Onduleur a Onde Sinusoidale Pure de 650 watts d alimenter votre appareil ou quipement effectuez un test Tous les Onduleur Onde Sinusoidale Pure sont con us pour s arr ter automatiquement lorsqu une surcharge de puissance survient Cette fonction s curitaire pr vient les dommages l unit lors des tests avec des appareils ou des quipements dont la charge pr vue se trouve dans la gamme des 650 watts Si un appareil fonctionnant dans la gamme des 650 watts n op re pas correctement lorsque vous le branchez pour la premi re fois onduleur commutez rapidement l interrupteur bascule de l alimentation aux positions ON MARCHE 1 OFF ARRET O et ON MARCHE 1 Si cette proc dure ne r ussit pas il est possible que l Onduleur Onde Sinusoidale Pure m ait pas la capacit requise pour alimenter l appareil en question Raccordez votre onduleur a la source d alimentation de 12 volts Pour la connexion de l onduleur la source d alimentation nous recommandons que le cable du plus gros calibre disponible soit utilis et q
27. ures corporelles caus es par les chocs lectriques ou le feu Les condensateurs internes demeurent charg s lorsque l alimentation est coup e Pour r duire les risques de blessures d branchez les deux alimentations CA et CC de l onduleur avant de proc der tout entretien ou nettoyage La commutation hors circuit OFF ARRET ne r duit pas ces risques e Ne serrez pas trop les crous des bornes d entr e CC Vous pourriez endommager les bornes e Les bornes l arri re de l onduleur deviennent suffisamment chaudes pour br ler la peau Soyez prudent lorsque vous d branchez les fils lorsqu une charge importante a t branch e l onduleur Sp cifications PUISSANCE DE SORTIE Puissance continue 650 W Puissance de pointe 1200 W TENSION CC D ENTR E PROVENANT DE LA BATTERIE Syst me de 12 volts CC 12 volts CC nominal 11 15 V TENSION CA DE SORTIE DE L ONDULEUR Tension 110 volts CA 10 efficace Fr quence 60 Hz 2 Hz Forme d onde R gulation efficace onde sinuso dale pure Efficacit 90 SYST MES DE PROTECTION Syst me de d marrage progressif Oui Arr t lorsque la batterie est basse Oui Arr t aux surtensions de la batterie Oui Arr t aux surcharges en sortie Oui Arr t aux surchauffes de surcharge Oui Arr t aux courts circuits Oui PHYSIQUES Ventilation Ventilateur haute vitesse Poids 3 73 kg 4 4 kg 8 22 lbs Dimensions 33x23x9cm 12 99 x 9 06 x 3 54 D pannage Panne Cause Solution Tension
28. verter dry Do not expose the inverter to water or moisture 3 DO NOT use the inverter if you the inverter or anything that will or has come in contact with the inverter are wet Water and other liquids conduct electricity which may lead to serious injury or death 4 Avoid placing the inverter on or near heating vents radiators or other sources of heat Do not place or use the inverter in direct sunlight Ideal ambient temperatures should be between 50 and 80 F 10 and 26 C 5 In order to properly disperse the heat generated from the inverter while it is operating keep the inverter well ventilated Keep the area surrounding the inverter clear while in use 6 Do not use the inverter near flammable materials Do not place the inverter in areas such as battery compartments where fumes or gases may accumulate Inverter Protection Features 1 Short Circuit Protection The inverter will automatically shut down until short is removed 2 Low Voltage Alert An alarm will sound when the voltage from the battery discharges to 10 5 0 5 V DC This is an indication that the battery needs to be recharged 3 Over Voltage Protection The inverter will automatically turn itself off when the input exceeds 16 5 1 0 V DC 4 Under Voltage Protection The inverter will automatically turn itself off when the input is less than 10 0 0 5 V DC 5 Overload Protection The inverter will automatically turn itself off when the continuous draw of
29. xc de 1200 watts 6 Protection thermique Le panneau d etat a DEL s illumine en rouge et l onduleur s arr te automatiquement si la temp rature du circuit exc de 150 F 65 6 C 7 Protection contre la surchauffe L onduleur est quip d un ventilateur qui est con u pour fonctionner continuellement lorsque l onduleur fonctionne L arr t automatique de l onduleur cause par la surchauffe des circuits survient lorsque le ventilateur est incapable d assurer le fonctionnement une temp rature s curitaire Dans le cas d un arr t automatique ou d alarme audible constante tournez l interrupteur de l onduleur a la position OFF ARRET jusqu ce que le probl me soit determine et corrig Suggestions portant sur la reception des signaux de TV et sur les chaines audio M me si tous les Onduleur Onde Sinusoidale Pure sont blind s et filtr s pour minimiser les interf rences avec les signaux certaines interf rences pr sentes dans votre image de t l vision peuvent tre in vitables particuli rement lorsque les signaux sont faibles Cependant voici quelques suggestions qui peuvent aider a am liorer la reception 1 Assurez vous que l antenne de t l vision obtient un signal clair dans les conditions normales de fonctionnement lorsque la t l vision est branch e a une prise de courant standard de 110 volts CA Assurez vous aussi que le cable de l antenne est blind ad quatement et ou de bonne qualit 2