        MEA 说明书.cdr
         Contents
1.       7   INDICATOR    DELAY   UNDELAY  SELECTOR  lt                 POWER SWITCH                           Rear Panel  3000VA 5000VA       INPUT   OUTPUT                                              3  INDICATING SIGN       rd   N  WORKING    jf  ES    DELAYING               UNUSUAL    WHEN THE GREEN INDICATOR IS LIGHTING  THE  REGULATOR IS WORKING     WHEN ORANGE INDICATOR IS FLASHING EVERY  ONE SECOND  THE SYSTEM IS TURNING INTO  DELAYING STATE  AND THE REGULATOR HAS NO  OUTPUT  AFTER DELAY  ORANGE INDICATOR WILL  EXTINGUISH AND THE REGULATOR RESUME  OUTPUT     WHEN OUTPUT VOLTAGE OF AVR IS HIGHER THAN  SET VALUE  THE SYSTEM ENTER INTO HIGH  amp  LOW  VOLTAGE PROTECTION  UNUSUAL RED LED  FLASHES EVERY ONE SECOND AND OUTPUT GOES  OFF WHEN OUTPUT VOLTAGE OF AVR IS UNDER  SET VALUE  THE SYSTEM ENTER NORMAL WORKING  STATE UNUSUAL RED LED EXTINGUISHES     WHEN TEMPERATURE OF AVR IS HIGHER THAN SET  TEMPERATURE  THE SYSTEM ENTERINTO  TEMPERATURE PROTECTION  UNUSUAL RED LED  FLASHES EVERY ONE SECOND AND OUTPUT GOES  OFF WHEN TEMPERATURE OF AVR IS LOWER THAN  SET TEMPERATURE  THE SYSTEM ENTER INTO  NORMAL WORKING STATE  UNUSUAL RED LED  EXTINGUISHES    NOTE  Indication for overheating is not equipped in  standard configuration  This function should be effective  only after users notify manufacturer in advance                 4  LED INDICATOR ILLUSTRATION    LED Indicator Illustration  CONDITION WORKING G  DELAYING Y  UNUSUAL R    Power Off           Working       Delay State      
2.       c paco    MICROPROCESSOR CONTROL  CPU     AUTOMATIC VOLTAGE REGULATOR    HIGH  amp  LOW VOLTAGE PROTECTION                            Instruction Manual  Please read user manual carefully before use                 1  FEATURES    Microprocessor Control  CPU    Wide Range Voltage Regulation   Automatically Executes Protection  When Protection Finished  Goes Off   High Voltage Protection  Yes   Low Voltage Protection  Yes   Overload Protection  Yes  3KVA 5KVA    High Temperature Protection  Yes   Circuit Protection  Circuit Breaker   Smart Cooling System  Yes  3KVA 5KVA     2  DESCRIPTION    FIG 1    Front Panel  300 500VA Rear Panel  300VA 500VA    OUTPUT VOLTAGE  METER    INPUT VOLTAGE  METER                WORKING  INDICATOR       DELAYING  INDICATOR    Fuse         UNUSUAL      o        INDICATOR    2       Input Ec  DELAY   UNDELAY    SELECTOR         _ up O Output                                              POWER SWITCH                     FIG 2       Front Panel  1000VA 2000VA    OUTPUT VOLTAGE    METER    INPUT VOLTAGE  METER                    WORKING  INDICATOR  lt           DELAYING  INDICATOR      _      UNUSUAL  INDICATOR            DELAY   UNDELAY  SELECTOR         71                POWER SWITCH      Rear Panel  1000VA 2000VA                   Fuse aD     o        Input Ec     Output                FIG 3  Front Panel  3000VA 5000VA    OUTPUT VOLTAGE  METER      INPUT VOLTAGE          METER  WORKING  INDICATOR    DELAYING  INDICATOR 4       4    UNUSUAL   4 
3.     Voltage 235V   Protection   Input 250VAC   250VAC  250V AC  250V AC  16A 25A   Fuse T5 0A T8 0A T10A T15A   Fuse Circuit Circuit   Size 5x20mm 5x20mm 5x20mm 5x20mm breaker breaker   Delay 6 secs    120 secs    Time   Thermal o   Protection  130       5    Cooling Yes Auto operation fan   Fan No No No No  temperature or load    Dimension  24 5x11 3x16 5  26 3x12 5x17   28 3x14x19   28 3x14x19  39x21 5x26 39x21 5x26    LxWxH   cm cm cm cm cm cm                           specification are subjected to change without prior notice     10                   CAUTION    e Avoid overloading  Do not use the regulator beyond its maximum power     e When connected to any appliance with built in motor compressor  the  starting power is generally several times of the appliance s listed power  rating  Make sure that the total starting power capacity of all connected  appliance does not exceed the listed maximum output power of the  regulator  For color TV  calculate it twice as its listed capacity       Make sure thatthe regulator is of the same output voltage and frequency  as the appliance s it connected        Make sure that the voltage of electrical source is within the listed range  ofthe input voltage of the regulator      gt         Always place the regulator in an environment that is   O  i      A  Well ventilated  A 72   B  Not exposed to direct sunlight or heat source         C  Out of reach from children  uD   D Away from water moisture oil or grease      E  Away from any flam
4.  Output high voltage protection       Output low voltage protection             NOTE    X   CONTINUOUSLY ILLUMINATE  yx   FLASH         EXTINGUISH    NOTE  Indication for overheating is not equipped in standard  configuration  This function should be effective only after users  notify manufacturer in advance     5  OPERATION        Before use  please make sure the voltage and power of the appliance  are accord with the labeled power and specification of the unit to avoid  any damage         Please connect the appliance before turning on the unit  Switch on  appliance after you make sure the unit is working normally with output  voltage        When connecting the electrical appliance with motor or compressor  such  as drill  air conditioner and so on  to the automatic voltage regulator   please make sure that the power rating of the automatic voltage regulator  is atleast 3 times of the power rating of the electrical appliance  so that it  can work smoothly  because the starting up power is much beyond of the  power rating of the electrical appliance     4                e When DELAY OFF  the system is entering into countdown position  delay  time is 6 seconds   When DELAY ON  the system is entering into countdown position  delay  time is 120 seconds     HOME MAIN SOCKET          Turn on   secondly               Turn on   firstly    NOTE  DELAY only takes effect when the system is restarted into normal                 6  LOW  amp  HIGH VOLTAGE PROTECTION       When output volt
5.  land based installation  the earth terminal should be  connected to a metal earthing stake driven into the ground to a depth of  1 2m      more     Model  3KVA  5KVA                                         oe                                      GROUND TERMINAL             EARTH STAKE 1 2M       NOTE  The earth terminal of the AC outlet is connected to the neutral terminal   This is the same as a standard household power point where the neutral line is  bonded to earth and there is normally no voltage between them     12 CAUTION    e In case of trouble with the AC output  e g short circuit  overload  etc    the  protection circuit will automatically cut off the output   In such cases    A  switch off the power at once   B  disconnect all units   C  check the connected devices   D  use the unit again unless the problems  concerning the connected devices have been solved       When in use for a prolonged period of time  the AC output may suddenly be  cut off although the input voltage normal  This may be caused by excessive  temperatures  If this happens  Please proceed as follows     A  Switch off the automatic voltage regulator at once    B  Disconnect some of the appliances or wait until the automatic voltage  regulator cools off    C  Switch the automatic voltage regulator back on    8                    Always keep the automatic voltage regulator in an environment which is    A  Well ventilated   B  Not exposed to direct sunlight or any other heat source   C  Inaccessible
6.  to children   D  Safe from water moisture  oil or grease   E  Safe from any flammable substance    WARNING  DO NOT DISASSEMBLE THE UNIT  HAZARDOUS VOLTAGE  DANGER   PLEASE RETURN TO THE DEALER IF YOU FIND ANY PROBLEM WITH THE UNIT    13  MAINTENANCE       Very little maintenance is required to keep your automatic voltage regulator  operating properly        You should clean the exterior of the unit periodically with a damp cloth to  prevent accumulation of dust and dirt  At the same time  tighten the screws  on the AC input terminals     14  EXPERT OF PROTECTOR FOR      Make sure that the to tal laden power does not exceed the listed maximum  output power of the regulator   Be sure to connect the ground point to the ground for your safty     Expert of Protector For                                                                                                        15  SPECIFICATION                                                                                                          P No  MEA 500VA   MEA 1000VA  MEA 1500VA  MEA 2000VA  MEA 3000VA  MEA 5000VA   input 100 260V  120 260V  140 260V  80 140V    Voltage   __ 190 260v   __ tz0 26ov     tav zs0v             Output   Voltage 220V  230V  240V  110V  115V    Output   Power 500VA 1000VA 1500VA 2000VA 3000VA 5000VA   Frequency  50 60Hz   Output     Precision     10    High   Voltage   Circuit Protection   Protection   Low   Voltage   Circuit Protection   Protection      Circuit Protection  rotection    High   Output 
7. age is lower or higher than labeled voltage  AVR will turn  into self protection state automatically the UNUSUAL RED indicator  flashes every one second and output voltage will be cut off     5                   When output voltage comply with labeled voltage  AVR will go into  automatic recovering state  the UNUSUAL RED indicator extinguishes   Then DELAYING ORANGE indicator flashes every one second  the  system goes into delaying state  After delay  DELAYING ORANGE  indicator extinguishes and output voltage resume      7  THERMAL PROTECTION    e When the temperature of the transformer exceeds 130  C   5    the  system will automatically turn into self protection state  UNUSUAL RED  indicator will flash every one second and output voltage shut down  While  temperature is lower 70  C   5    the system will recover automatically   UNUSUAL RED indicator will extinguish  and output resume     NOTE  No overheating Protection is equipped in standard configuration   users should notify manufacturer and take special order if this function  is required     8 0VERLOAD PROTECTION       When avr is overload  the system will turn into self protection  red led  indicator will illuminate continuously and there is no output  To resume  the output  you should lessen the load and then restar the unit     NOTE  This function only suitable for 3KVA   5KVA    NOTE  No overload Protection is equipped in standard configuration   users should notify manufacturer and take special order if this funct
8. ion  is required     9  WITH COOLING FAN       When the temperature of transformer excessed 90 C    5   the cooling  fan will switch on automatically to low down inside temperature and will  stop working while the temperature comes down     NOTE  This function only suitable for 3KVA   5KVA     10  OUTPUT CAPACITY       The automatic voltage regulator will switch off automatically if the total  wattage of the electrical appliances exceed the automatic voltage  regulator output capacity     6                e If this voltage is in the range of 190 250V  the regulator provides the    100  listed maximum output power  maximum output power will change  as the curve shown below            100  75  50  25          OUTPUT  220V     USE THE SAME CURRENT  FUSE FOR REPLACEMENT    100 120 140 160 180 200 220 240 260 280 300U V   THE POWER CURVE OF OUTPUT    11  GROUNDING CONNECTION    WARNING  BEFORE USING THIS AUTOMATIC VOLTAGE REGULATOR    YOU MUST PROVIDE AGROUND CONNECTION TO THE AUTOMATIC  VOLTAGE REGULATOR        On the rear panel of the automatic voltage regulator there is a terminal fitted  with a nut  This terminal is connected to the case of the automatic voltage  regulator and also to the earth terminal of the AC output socket  The use of  this terminal will depend on your particular installation  In any installation   heavy duty  green insulated wire should be used for this connection              Model  300VA  500VA  1000VA  1500VA  2000VA  7                    Inastationary
9. mable substance  eo               
    