1.  the scale       For built in rechargeable battery version     Apply the power adaptor and recharge the       scale immediately  Fail to do so may cause          unrecoverable damages to the rechargeabl       battery inside scale     TARE INDICATOR  An arrow will appear and point at this sign    to indicat th tar function is in          operation and weight displayed is net    weight     7  ZERO INDICATOR  An arrow will appear and point at this sign    to indicate a zero weight status        IN CHARGE INDICATOR  BUILT IN RECHARGEABLE  BATTERY VERSION   This indicator is located at the left hand          side of the scale  Charging status IS  displayed by different colors   Red  Recharging battery    Green  Charging completed    4  OPERATIONS  4 1Routine operation     a  Switch power on  The unit will begin a       self    testing sequence  The scale is ready for       use when the display zeros  The measuring unit       for the weighing value will be in kilograms  initially   b  Press the    MODE    key to select the desired       measuring unit   kilograms or pounds        c Ifthereisacontainerplacedontheplatter   press    TARE    key to subtract the weight of the    container previously        d  Start to weight       Optional back lighting facility  Press    MODE    key  there are 4 modes to be switch       over in sequence   kilograms without    back lLlight     gt  pounds without back light     gt        kilograms with back light    gt  pounds with  back light        4 2
2. 0peration notes     Grounding     Ground the instrument properly to protect the  instrumentation from power surges  This can    be done by using a suitable adaptortransformer       with a third ground terminal  Any method of    grounding should comply with local electrical          regulations  Do not ground the GMto gas pipes   water pipes  or to telephone plugs     Warm up period       For best results  a minimum 10 minute period    of disuse prior to operation is highly       recommended    Enabling and disabling the Auto shut off  mechanism   When the scale is turn on  the auto shut off    mechanism is set at four minutes  To disable             or to enable again this power saving function    follow these instructions    a  Press the    OFF    key    b  Press and hold the    TARE    key    c  Press the    ON ZERO    key  the display will  show    FI       d  Press    TARE    key to switch the display to     F4     Then press    MODE    key  the display  will read    4 OFF    or    O OFF           Press the    MODE    key to switch between the    two modes   f  Press    ON ZERO    to reset the scale for    normal operation        Handling the scale       Despite the sturdy appearance of the scale     each unit houses sensitive instrumentation       which may be damaged by careless handling of  the scale  Use both hands when transporting    the scalewithat least onehandunderthescale         This will be routinely required if the             charging site for the rechargeab
3. GM SERIES  ELECTRONIC WEIGHING SCALE    OPERATION MANUAL             PLEASE READ THIS MANUAL VERY CAREFULLY                                  BEFORE ATTEMPT TO OPERATE THE SCALE                         AUGUST 1999 REV 2       Specifications subject to change without prior    notice    CONTENTS       1  INTRODUCT          ION          2s NSTALLAT          ON          3  EXPLANAT                ONS    4  OPERATIONS                5  CALIBRAT             ON       6  CARE AND          7  WARRANTY       MAINTENANCE                1  INTRODUCTION       Congratulation for choosing an excellent    digital weighing scale              Reliable and accurate  the GM series is ideal       for supermarkets  grocery stores  foodservice          shops  or retail stores        The GM series has been designed to be          asy to use  durable  and portable  with an    standard sealed type rechargeable battery and       matching AC adaptor rear display and       back lighting capabilities are available as    option   1 1Models  amp  Specifications     Capacity    1 3000       0 005kg    lkg  lg 1 11000                            fencraaige  eum Bull capacity         o o    AC adaptor    Option    Input  AC 110 220V              Rear side display  Back lighting facil          AC DC  rechargeable battery  6V  Consumption joperated DC  40mA hr    10     50 60Hz Output  DC9V 500mA    ity       evel ng facility             RS  ee Printer       nterfac       Operating ove   40  C  32 104  F   Tempera
4. le battery is       not the same as the operation location         Placing a load  Always place a commodity gently onthe platter   Sudden shocks will damage the weighing sensor    irreparably  Careful attention to avoiding       shocks will extend the life of the sensor     For best results  do not leave loads on the       platter for prolonged periods  as this may          impair the functioning of the weighing sensor        afterwards     Handling the plug       Disconnect the cord by the pulling on the plugs    only  never the cord itself     Exposure to liquids   Only clean the scale in a manner prescribed  by the instructions below    Should water or another liquid seep into the    enclosure  unplug the unit and have it checked       by your qualified personnel before operating       it any further    Care should be taken when drinking beverages  near the scale  and when placing beverage  containers on or near the scale   Thunderstorms    The GM is equipped with a lightning protection       circuit which can prevent about 90  of the  damage typically caused by lightning  The    effectiveness of the circuit depends on how       well grounding the instrument is     However  during severe electrical storms it       is strongly advisable that the scale be  switched off andthat the adaptor be completely  disconnected from the local power source   Long term storage    Charge the battery fully for an uninterrupted          eight hours  Be sure that there are no load       left 
5. onthe platter  Clean and cover the scal       CARE AND MAINTENANCE    Do not subject the commodity platter to       sudden shocks     Clean the cover and commodity platter with             a soft damp cloth and mild detergent  Do  not sue harsh abrasives   Do not submerge the scale in water and do    not pour splash or spray water directly on       Lts       Do not use acetone or other volatile  solvents for cleaning     In order to prolong the battery life  please          refrain from using any longer before       ce     recharging when  low battery sign     appears     
6. ose the delicate electronic components   NOTE            Refer all servicing to qualified personnel at    an authorized dealership only  Otherwise  the    warranty may be invalidated     Safe use of Power Sources     Check that the voltage requirement for the AC       adaptor are provided  but not exceeded  by the    local power supply        Insert the adaptor plugs securely into a power    socket first  then the receptacle on the       right bottom side of the scale     Avoid connecting other equipment to the same       socket  Secure the adaptor cord such that it  will not be stepped on or pulled  if possible           If an extension cord must be used  it should  have a equal to or exceeding that of a suitable    power source     3  EXPLANATION  3 1Keypads  amp  Displays         4  o  50  one   O       1  OFF KEY    Press this key to turn scale off     2  ON ZERO KEY  Press this key to turn scale on or set weight    to zero when unloaded     3  TARE KEY  Press this key to tare off the weight of    a container     4  MODE KEY  Press this key to switch among metric and    avoirdupois weight units with or without          backlight  optional      LO BAT INDICATOR    When this indicator appears          For dry battery version  replace the    batteries with new ones  or apply the power       adaptor immediately     CAUTION   When the power adaptor is being used  take  out all the batteries fromthe batterypack     Fail to do so may cause battery    leak explosion or damages to
7. ture       2  INSTALLATION  2 1Unpacking     Unpacking the scale carefully  within this    package you will find        a  This manual   b  The GM scale   cC  The platter   d  The adaptor  9V 500mA   e  The dust cover    NOTE  Do not dispose of the box or packing    materials  since they may be useful inthe       K     future when long range transportation is       called for   2 2 Optimal installation requirements     For optimal results we recommend that you  install the scale at a location that provides  for the following    A level surface    a  b  Stable and  or not subject to vibration    Q    Not exposed to direct sunlight    Q    Away from areas containing corrosive gas       Dust free    f  Temperature EOE O       g  Humidity  lt  95  RH  Do not install near a       humidifier     h  Away from other electronic equipment to          avoid interference  If a leveling bubble    is included  center the bubble with the            leveling feet before using the GM scale     Follow the precautions outlined below on          the safe use of electrical power sources           Connect the GM to the local power source    and charge the battery completely  while       the display is switched off  Be sure that                the scale is safely out of the way while    it is charging     2 3Precautions        Warning   Do not attempt any troubleshooting  or maintenance other than that mentioned in    this manual        Do not open the scal nclosure for any reason           and exp
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Snom 320 IP Phone Quick Start Guide - Use-IP  CogniPlus: Training cognitive functions  FC-200V FC-100V  Chapter 8: Using the WinBUGS interface in MlwiN  Les tigres sauvages  manutenção da piscina tratada com o sistema de ionização “hidrion”  Safety in Storage, Handling and Distribution of  Operating Instructions  Télécharger les tarifs Quads Polaris 2012    Copyright © All rights reserved. 