1.                                 DISTO    pro      pro  a 1 0 0en X65   English         Basic functions   4 iusso inene reto tne E E ie E 29  Maximum tracking  4 1     s  Minimum tracking   4 2     icc tte treten rennen etes  Required  distance   4 3     ntt rettet aa  Pythagoras  4 4  233  Lieidll 4 5  o etc hu cte MEM LR ONLUS  Peel ao                        A  Average value  4 7    m    re ETTE ATO TRIA o  eM PE P PEE AEE A E T cee   Triangle  ERICH 37  Triangle SH  5 2  a  Trapezium HSH  9 9   sconto eines lr etri te tete ene eet 39  BI crai m           40  Gable area  5 5  2   CICS n P                 ACE  I Me mc   Memory  6      f s9 recallikey  Gill    osos eios rae t s teri Moai dte 44  N  9recalll key                                   c 45  Stack  6 3     Data  6 4    Calculator  7   Division  7 1  ak  AT                  eP leceea  KHU en as  se 50                            User INFORMATION rrt corica recto ci roma rutru Por erae eee cin 51    PRAM GG rome                                      ROUGh SUfaCes   tenere irent aaepe reete adepta p dares dette beg ste ved feste el Picea  Transparent surfaces hes  Wet  smooth and high gloss surfaces                     ssssseeeen 51  Inclined  round SUrfaces        5   1 neret tnter tntet etes erento 51  Free  handed aiming  Measuring in the field   Setting viewfinder          Contents  cont          contd     ACCOSSOMIGS a sstescsasssvsssesstvenzasatsesacsvisuasadsssucsebatesaraistevenduavesenstctevendadtevarsckavardastes
2.       A line of text can be replaced  E by a list  Read menu    function Store  6 4 2    Press briefly to store  changes     After a confirmation the basic  settings are displayed     Erase  6 4 4   This menu function erases the entire  data memory     After calling up this menu function  a  request is displayed        erase  entire  memory      DISTO             Cancel menu function        Press briefly to display the  submenu  data   6 4  or  press and hold to display the  basic settings     Erase      Press briefly     After erasing the data memory a  confirmation is displayed and then  the basic settings        Send  6 4 5   send 6 4 5  2 position                This submenu transmits the contents  of the data memory via the data  interface to a PC or a laptop     All  6 4 5 1   This menu function transmits the  entire data memory contents     During transmission  the number of  the current data memory location  being transmitted from is displayed     At the end of the transmission the  submenu is displayed again     Position  6 4 5 2   This menu function transmits certain  locations of the data memory     DISTO    pro      pro  a 1 0 0en   49    E   English    Memory  contd     After calling up this menu function   the following is displayed        6 4 5 2    001  gt   200    position    LI              The vertical bar shows memory  location from the first to the last  location     Selecting memory locations for data  transmission      Place arrow on the first or  last 
3.       DISTO    pro    pro  a 1 0 0en    cone LLLLLLASSSX   V    Product identification                       sss tenete 4  SYST 4     peior e                                   Special feat  fBs    raices riti epe Leiter pe entre ee rte test bote eter cete  Area of applicability      Mod  s of OpefatlOli  osi eerte etaed lt rente te tries ette ize   huuc Boo                       7  Pointing mode     Measurihd MOJE  tissas iaeiae anaana sete puces latti ehe rep ce 7          Instrument description    we 8  SlandardsCquipMeNt E              aiaa 8  BasiCinStruMemt P                  DISPIAY EN                                            Special symbols n  EDEN CREE         uu                                   Table of characters ia  Inserting   replacing the batteries    tenes 13            How to use instrument                    essent tnnt ntnnentnn 13  Switching on DISTO                            14  Switching on DISTO for the first time                   ss 14  Switching on  Pointing  mode    inen tntanntarit aaa 14  Switching off DISTO iss  UE TD T                             P    UPHHIID A                              Selecting menus   menu functions       Short CUL Gaana a ani tuni turca uan IR NEU PNE 16  Correct menu selection 16  Reset menu functions    is  educ                 M  USING eid COVGIS    citm eee oiim enar ete pct ciere ret rag  Automatic end cover recognition   T  Charging Nd  COVERS    associer intet tienne tigre int cinta re eR LR REIR cran           
4.      Measuring from flat planes  Measuring from corners         Measuring B UST  t  Measuring with stand                        sse tentent ttnt tentent nien  Measuring with alignment aid        Measuring with accessories                   ssssssseseeeeentete tenens       Simple Calculations    length  astra m  Total height  total GiStanCe        2           eese tentata rto tt repiten  Partial heights  partial distances                        sse 19  Doubling a measured value B  Cro                                                        Menu Functions        cscssssssessesessessessessessnssessesensseesessnsseestsntssesnsateeesnenteanentens 20  Measurement settinigs  1     eite nter rece rztetat tare ct aret disaini 20  Measurement reference  1 1                    ssssssseeente tentent 20  Add   Subtract  1 2      Time delay release   1 9     cette nectit cette rta cora etna 22  Lasar  1A  pe  Tracking  1 5       fi  Data transfer  16  sssini aikanaa  End COVETS i9                                 Without end cover  2 1          Adapter end CoVer  2 2     cete trente trt cet ceret rta ceri p eed otuk  Recognition  2 3     itc seti reete aaaeaii pisc Heres eet  Swivel foot  2 4     Alignment ald  2 5      1     22  1 rr tittenttrsercce crise rte tbt teta cede eren tne  Basic Settings  3  m           Units  3 1  5  Languade  3 2  C                w                              Beep  3 3   Reset  3 4  is  Lighting  3 5  M              sei iasta  Suenistn m E                     
5.      Press briefly to change into  W the measurement mode and  to start stake out     Aim laser at target        Y n0     0 125m          X n 01  0 000m                The screen displays      the number of the next stake out  point  n       one or two arrows that help in the  settings      the current distance between the  reference of the DISTO and the  stake out point     Now move DISTO slowly and in a  straight line towards the stake out  point     The arrow in the display points in the  direction of the next stake out point   The distance displayed starts to  reduce down as soon as DISTO is  moved in the right direction towards  the stake out point     Once near the stake out point a short  beeping sounds starts and turns into  a continuous sound when the stake  out point has been reached     The exact stake out point is marked  by two arrows and the distance  displayed is zero     As soon as the laser is pointed at  another target  the next stake out  point is displayed     To terminate stake out press        one of the keys briefly     DISTO changes into Normal mode  and displays basic settings     DISTO    pro    pro  a 1 0 0en EENCIEENT English    Basic functions  contd     The distance between stake  E out points is divided into  distance fields  Each stake out point  lies in the middle of the respective  distance field     As soon as the DISTO is moved   between two stake out points to a   new distance field  then     the number  n  in the display  changes      the
6.     Addition  1 2 1   After calling up this menu function  the following is displayed        addition 1 2 1     A  0 000m             oo    E    Enter Add with keypad  recall  it from the keypad or stack    memory     Press briefly to display the    units of Add     Meters are automaticlly  added without having to  press the menu key     Press briefly to confirm    entered addition     Press briefly again to  terminate menu function     A short confirmation is displayed     IN    DISTO switches to Normal  mode and displays in the  uppermost line of basic  setting the symbol of the    addition        DISTO    pro    pro  a 1 0 0en       English    Measurement settings  contd     Add     is valid for all following  measurements      is automatically suggested at the  next menu function call up     Subtraction  1 2 2   After calling up this menu function   the following is displayed     subtraction         0 000m             Enter subtraction with keypad  or call it up from the keypad  or stack memory     Do not enter minus sign for  subtraction     E    Press briefly to display unit of  subtraction     Meters are automaticlly  E subtracted without having to  press the menu key   Press briefly to confirm  entered subtraction     Press briefly again to  terminate menu function     A short confirmation is displayed and    the DISTO switches to Normal mode     The uppermost line of the  basic setting displays the  symbol of the subtraction     A     Subtract     is valid for all fo
7.     The result is displayed in the basic  settings     x  7 2    Precondition  The first value to be  computed with has to appear in the  basic settings     After calling up the menu function the  computation is performed  immediately and the result displayed  in the basic settings     Square root  7 3    Precondition  The first value to be  computed with has to appear in the  basic settings     After calling up the menu function the  computation is performed  immediately and the result displayed  in the basic settings     DISTO    prot   pro    a 1 0 0en       User Information       Range    In daylight  outdoors  always work  with a laser viewfinder  If necessary   shade the target area     Increased ranges   At night  at dusk and when target  area is in the shade     Reduced range    The range of the DISTO can be  reduced by matt  green and blue  surfaces  also by trees or plants      Rough surfaces    Rough surfaces  e g  coarse plaster   a mean value is indicated     To avoid measuring to the bottom of  plaster joints  Use target plate   3M  Post it  or board     Transparent surfaces    To avoid measuring errors  do not  measure towards colorless liquids   like water  or  dust free  glass    For materials and liquids unfamiliar  to you always take a trial  measurement      m When aiming through panes  of glass  or if there are   several ojects in the line of sight    erroneous measurements can occur     Wet  smooth and high   gloss surfaces    1  Aiming at a  flat  angle
8.    After a short confirmation the  contents appear in basic settings     Recall with short cut    Press briefly to call up main  menu     o 0  0 0 5    Enter short cut for menu function   recall key 1 9   6 2  and add the  number of the desired memory  location  1   9      Memory  contd     After saving a short confirmation  appears  then the basic settings     Recall with 0 key    Press until there is an    audible beep  approx  1 sec      If the key if pressed for too  E long the stack contents is  displayed  6 3         recall key 1 9 6 2    LT         9 125          The first memory key is displayed     Select memory key with  navigation keys or select  directly via keypad entry    Press briefly to display  contents     After a short confirmation  basic  settings are displayed     Stack  6 3     The stack saves the last 15  measurements  computations or  entries automatically to a shift  register  This means the saved  values have no fixed allocation but   shift  through the stack     When all 15 memory locations in the  stack are occupied  each new entry  will delete  overwrite the most recent  memory location used     Default setting  after reset the stack  is deleted  3 4     Recall with menu  After calling up the menu function   the following is displayed        stack 6 3       1 891          The arrow stands for recalling the  stack  the number beside it shows  the memory location in the stack   1 15      Below the current memory contents  is shown or  0 000  if the 
9.    User Manual  Version 1 0  English    Geosystems    DISTO    pro   pro a hand held laser meter    Congratulations on your purchase  of a DISTO        Leica Geosystems products are of  top quality  are top performers and  provide the higest degree of  productivity     A al This User Manual     contains important  safety instructions  see section   Safety Instructions   as well as  instructions on use of the instrument   Read carefully through the User  Manual before you switch on the  instrument     Product identification    Enter model designation and serial  number in your User Manual  and  always refer to this information  when you need to contact your  agency or service centre           Model  DISTO          Serial no                           PD Z01          Symbols used    The symbols used in this User Manu   al have the following meanings     DANGER    Indicates an imminently  hazardous situation which  if not  avoided  will result in death and  serious injury     WARNING    Indicates a potentially  hazardous situation or an unintended  use which  if not avoided  could  result in death or serious injury     CAUTION    Indicates a potentially  hazardous situation or an unintended  use which  if not avoided  may result  in minor injury and or in appreciable  material  financial and environmental  damage     Important paragraphs which  E must be adhered to in    practice as they enable the product  to be used in a technically correct  and efficient manner        English 
10.   C   14  F to  122  F  10  C to  50  C   14  F to  122  F                   DISTO    pro      pro  a 1 0 0en   59 English    Remarks on Measuring Accuracy    Both references         relate  E to the technical data on the  previous page      The measuring accuracy  corresponds to the ISO   recommendation ISO R 1938 1971  with a statistical confidence level of  95   i e    twice the standard  deviation   The typical measuring  accuracy relates to average  conditions for measuring within the  specified range     Measurement accuracy is not valid  for     basic functions  except stake outs      calculation      continuous measurement  tracking      The maximum measuring error relates to  unfavourable conditions such as       highly reflecting surfaces  e g   reflector tapes       operating at the limits of the  permitted temperature range   adaption to ambient temperature  interrupted  page 54      very bright ambient conditions   strong heat shimmer and can be up  to x 5 mm  twice the standard  deviation         At long range   30 ppm    3 mm   100 m  plus short range error    Range increases  the better the  laserlight is reflected from the target  area  diffuse  not reflective   and the  brighter the laserpoint is compared to  the surrounding luminosity  indoors   dawn     From approx  40   50 m use target  plate  brown side     Possible method of calculating  the standard deviation s        99 7   95 4                                     3s  25    S x     S 55 13s           
11.   Height and width of buildings from a  distance      Measuring inaccessable parts of a  facade      Comfortably measuring while  standing without bending down or  using accessories such as target  plates     DISTO computes the desired length  by using two or three auxiliary  measurements based on a right   angled triangle applying the Pytha   goras function        PD Z27                Default setting  none    The auxiliary measurements require      That the preset measuring directions   triangle  be adhered to      The laser measuring points have to  be on one line in a horizontal or  vertical plane  Measurements made  over elevations provide wrong  results      The second auxiliary measurement  must be made perpendicular to the  desired length      The second laser measuring point  has to fall within the distance of the  desired length or be the end point of  that length      Only if measured distances are  short and the DISTO can be placed  firmly against an object should  measurements be done holding the  DISTO by hand  Exact  measurements require the use of a  stand     For vertical measurement  E always use the stand  connection on the adapter end cover  of the DISTO  Only in this way does  the axis of the laser beam run  through the point of rotation of the  stand     If the DISTO is used with the stand  connection at the bottom of the  casing then the axis of the laser  beam runs about 70 to 100 mm over  the point of rotation  This does not  matter when measuring in 
12.   If desired  enter text in the first line  as described earlier     This text is automatically  Eg used for the next following  results     The two other lines     are reserved for text input      contain text predefined by the  calculation function     Press briefly to store results  one after the other     After a confirmation the basic  settings are displayed     Change  6 4 3    With this menu function  data stored  to memory can be changed  subsequently     After calling up the menu function    the menu displays     the last stored value      the number of the memory location      the amount of occupied memory  locations and the occupancy of  memory in percentage     English     DISTO    pro    pro  a 1 0 0en    Memory  contd        change 6 4 3    200  5       5 125m          Select desired memory  location with navigation keys  or by keypad input     If desired the selected memory  location can be reserved to transmit  data to a PC     o Press briefly to reserve  memory location     KJ This symbol is displayed   pA Memory location and         contents remain unchanged     Press Clear key again to free up the  memory location for data transfer      Press briefly to start making  changes     D    Place cursor with the  navigation keys on the line to  be changed     DE    To delete press briefly           Enter new text or value with keypad  or recall it from the memory keys or  from the stack     Press and hold as desired     To add a measurement unit  press  repeatedly
13.   When using a computer with a  statistical function or if you use the  program Excel  you can calculate the  mean value x and the standard  deviation s directly from the 10  measured values     Formula for the standard deviation  S        s       Xi   x     Nive number of measurements  individual value of a series  of measurements   mean value of a series of  measurements     gt l    Calculation using the program Excel   On the Insert menu  choose  Functions   Select category  Statistics and  Function STABW within the Function  Assistant     Depending on the version of  E Excel and the language  used  the names of the menu may  vary     Accuracy Tests    Accuracy tests on the DISTO for  users certified to ISO 900       You can perform your own accuracy  tests on the DISTO to meet the  requirements of ISO 900    for  measuring equipment     Take a fixed  invariable  and  conveniently accessible distance of  about 1m to 10m  such as the width  of a window opening or of a room   Measure it ten times     Determine the magnitude of this  distance with a means of measurement  that is monitored by a national   accredited calibration institute   traceability back to national  standards      Determine the amount that the  measurements vary from the nominal  distance  and compute the standard  deviation     Record the standard deviation and  set a date for the next test        English       DISTO    pro    pro  a 1 0 0en       Repeat these tests at frequent and  regular intervals  als
14.   mark           PD Z59             In the field  check adjustment from  time to time  in semi shaded area  approx  10   15 m   Aim with or  without red filter  increases visibility                  Accessories  Accessories for measurements    Telescopic viewfinder  667478   For easier aiming in the field  For  highly accurate aiming while far  away from the object  four fold  magnification   Carry in holster  attachable to belt     Laser dot glasses  723777    Red filter glasses for improved  visibility in bright rooms or in the field  up to distances of approx 10   12 m     Target plate 563875  DIN C6   Target plate 723385  DIN A4   For poorly reflecting surfaces use   white side for up to 40   50 m   Beyond this distance  brown side  with the special reflection layer     Target plate  723774    For handy work indoors  Target plate  can be pinned or glued on    Target plate sizes    73 x 98 mm   147 x 98 mm    Bubble level  667158    For horizontal and vertical aiming   e g  when floor and walls are very  uneven        English       DISTO    prot   pro  a 1 0 0en    Accessories  contd   Safety Instructions   Instructions    Aiming accuracy is approx 1    corresponding to a measuring error  of only about 5 mm at a distance of  30 m     E    Short brackets  723775   50 mm long  for U shaped rails for  shutters     DISTO with this level is not a  laser level     Long brackets  723776   150 mm long  for measuring from  open windows     Stand adapter  725286    For correct measu
15.   the new conditions as you would for  a camera or a video     Transport    The Leica Geosystems holster  protects the DISTO well against  mechanical shock  but not against  water or dust     It is recommended that you always  transport the DISTO in the Leica  Geosystems holster or an equivalent  protective container or packaging     Pack the end cover into the holster  as shown below                    Do not exceed temperature limits     Please ask if you may take DISTO as  hand luggage when travelling by air     Despatch    Always use the original Leica  E Geosystems packaging   holster and shipment box  for  sending the instrument   You must remove the batteries  send  the instrument without batteries         English       DISTO    pro    pro  a 1 0 0en    Technical Data Data    COo DISTO pro  DISTO pro  a  typical     3mm   max    5 mm   typical       1 5 mm   max     2mm     0 16     approx 1 s    Laser visibility  635 nm visibility  635 nm     4 N    Tracking  continuous measurement  PM  Minimum maximum distance racking    800 measured values 800 measured values   Memory key for constant values 9 constants 9 constants   Stack  buffer  15 last values 15 last values   Graphic display  four lines  with LED    Alpha numeric keypad    End cover with swivel foot  IP54 acc  IEC60529  rain poof dust protected IP54 acc  IEC60529 rain proof dust protected    Temperature range storage 40  C to  70  C   40  F to  158  F  40  C to  70  C   40  F to  158  F  operations  10  C to  50
16.  Use of the Instrument    Permitted use   The permitted uses of the DISTO are  the following      Measuring distances     Computing using menu functions     Storing measurements    Prohibited uses     Using the instrument without  instruction     Using outside the stated limits     Deactivation of safety systems and  removal of explanatory and hazard  labels     Opening of the equipment by using  tools  screwdrivers etc    as far as  not specifically permitted for certain  cases       Carrying out modification or  conversion of the product     Use after misappropriation     Use of accessories from other  manufacturers without the express  approval of Leica Geosystems     Deliberate or irresponsible  behaviour on scaffolding  when  using ladders  when measuring  near machines which are running   or near parts of machines or  installations which are unprotected     Aiming directly into the sun     Deliberate dazzling of third parties   also in the dark     Insufficient safety measures taken  at the site of work  e g   taking  measurements on streets  etc      WARNING    Prohibited use can lead to  injury  malfunction  and material  damage    It is the task of the person  responsible for the instrument to  inform the user about hazards and  how to counteract them     The DISTO is not to be operated  until the user has been instructed     Limits to use   m See  Technical Data     Environment    Suitable for use in an atmosphere  appropriate for permanent human  habitation  Cannot
17.  adds the  desired unit  e g  m  m   m        Power on and measuring    key    Pressing the power on and  measuring key in Normal mode  Switches the laser to permanent  operation  1 4 2      Pressing the power on and  measuring key in Pointing mode  starts continuous measurement   Tracking  1 5 1  or  if using certain  menu functions maximum  4 1  or  minimum tracking  4 2      A tangible elevation in the  E middle of the keys facilitates    correct key presses e g  in darkness     Multiplications   Time delay  release    To multiply two or more measured or  numeric values  see section  Simple  calculations       A brief press in Pointing mode starts  the time delay release  pressing and  holding increases time delay  Upon  release the timer starts     To switch between capital and small  letters during text input      c  Clear key    A brief press  Clear Entry  deletes  the last entry or the intermediate  result of a computation     During computations within a  E menu function or in selecting  a menu setting the last display or  input is deleted as long as the result    enter key has not been pressed     Briefly press clear key one or more  times to move backward through the  menu     Press clear key for a long  E period to quit the menu  section and to return to the basic  settings in normal mode        Alpha numeric keypad 0 9    The 0 key displays a blank space   The 1 9 keys represent characters   see Table of characters      The availablity of these characters  depends
18.  and  hard to reach places  attach  the extendable telescopic rod to the  stand s connection        PD Z31                            Optional measurement attachments     Short bracket  723775     Long bracket  723776     Read user information under   Accessories     The DISTO has special menu  functions  2 2 2 and 2 2 3   to set  measuring references with these  optional devices     DISTO    pro      pro  a 1 0 0en   19   English    Simple Calculations   Sequential measurements can be   linked using mathematical functions   or input values    Corrective measures   o A brief press deletes repeats  the last entry  an intemediate    result or a faulty measured  value     Corrections are only possible  E if the Result   Enter key has  not been pressed     Length    Total height  total distance    Measurement   measurement   sum    Measurement  Addition    Measurement      Sum       In the same way chain  E measurements  any amount  of distance measurements  and  sums of areas   volumes can be  added up   Partial heights  partial distances    Measurements   measurements    difference    Measurement  Subtraction  Measurement    Difference    Doubling a measured value  It is easy to double the measured    value to obtain  e g  the  circumference of a room     Measurement  Addition    Measurement      Sum   half circumference     Length  contd     Volume       Repeat  double measured  value    Sum  circumference                 Area  Measurement x measurement   area    Measurement  
19.  are marked in black     Press briefly the change into  Pointing mode    Align DISTO and point with laser at   the first point to be measured     Trigger measurement  Hold  W  DISTO steady     Press and hold trigger key to start  minimum tracking    As soon as measurement is done  briefly press trigger key again     Press briefly to confirm  displayed value        triangle SH 5 2     N   3 147m        3 147m    Base length is displayed beside the  corresponding  1               English HES DISTO    pro    pro  a 1 0 0en    Calculation  contd     At the same time the next height to  be measured is marked in black with  the corresponding number  2      Measure height of triangle as  described and confirm with Enter  key     Press and hold to start maximum  tracking  Press again briefly when  measurement is done     Each of the displayed  E measured values can be    selected with the navigation key  again and corrected by a new  measurement     After confirming the last  measurement press briefly  again to start computation        triangle SH 5 2    An    3 439m           e Press again to quit menu and  return to basic settings     If desired save result to keypad or  data memory     Trapezium HSH  5 3     After measuring both heights and the   base side  HSH  of a trapezium  this   menu function computes     the length and slope of the  trapezium sides      the area of the trapezium     Applications      determine roof slope      determine gable area of a facade  with a shed ro
20.  basic functions  5 calculation  6 memory                The upper line of the main menu  shows the selected menu item with  numeric short cut     The horizontal black bar marks the  selected menu item  If all menus are  not displayable at once  a vertical roll  bar appears at the right side   indicating the availability of further  items     Repeated presses scrolls  down and highlights the  individual menu items           menu    2 end cover  3 basic settings  4 basic functions    5 calculation    6 EU                If required  press repeatedly  to scroll up to get back to  individual menu items     A brief press confirms  selection     Now a submenu appears or a beep  sounds  while briefly displaying a  confirmation     DISTO    pro      pro  a 1 0 0en   15 English    Using menus  contd        v    done                Short cut    Each submenu function has a  numeric code  a so called short cut  number     By entering the short cut number  a  submenu or a menu function can be  selected directly     Short cut numbers are listed  Eg in brackets when menus or  menu functions are being described   e g  1 4 2   An overview of short cut  numbers can be found in the short  cut index and in the Quick Guide     Press briefly      Enter short cut number e g   1 4 2 for permanent laser  operation     coo  amp     Submenus appear step by step until  the desired menu function     After the completion of the entry of  the short cut number the menu  function is carried out and a brief 
21.  be used in an  aggresive or explosive environment   Use in rain is permissible for limited  periods     Areas of Responsibility    Responsibilities of the  manufacturer of the original  equipment Leica Geosystems AG   CH 9435 Heerbrugg  Leica  Geosystems     Leica Geosystems is responsible for  supplying the product  including the  user manual and original accessories   in a completely safe condition     Responsibilities of the manu   facturer of non Leica accessories   E The manufacturers of non   Leica Geosystems accessories  for the DISTO are responsible for  developing  implementing and  communicating safety concepts for  their products  They are also  responsible for the effectiveness of  these safety concepts in combination  with the Leica Geosystems equipment     Responsibilities of the person in  charge of the instrument     WARNING    The person responsible for  the instrument must ensure that the  equipment is used in accordance  with the instructions  This person is  also accountable for the deployment  of personnel and for their training  and for the safety of the equipment  when in use    The person in charge of the   instrument has the following duties      To understand the safety  instructions on the product and the  instructions in the User Manual      To be familiar with local safety  regulations relating to accident  prevention      To inform Leica Geosystems  immediately if the equipment  becomes unsafe     Hazards in Use    Important hazards in use    WA
22.  confirmation is displayed     Ss Use the short cut to save    time when calling up  frequently used menu functions     Correct menu selection    Press briefly to display the  previous menu     Reset menu functions    The  Reset  command  3 4  enables  settings and menu functions to be  reset to a predefined basic setting   The basic settings are listed in the  description of the menu functions     Quit menu  o Press and hold to quit menu    and to display basic settings  in Normal mode     Using end covers    DISTO is delivered with the swivel  foot end cover already attached    Two additional end covers and  accessories  available as options   enable the instruments to be adapted  to varying measuring situations     Automatic end cover recognition    Magnetic sensors at the back of the  instrument make it possible to  recognize if an end cover with swivel  foot or positioning bracket alignment  aid has been attached    The instrument symbol in the basic  settings display includes the symbol  of the detected end cover and  measurement is referenced  accordingly     Automatic end cover  E recognition    does not work with the adapter end  cover     does not change the preset  measurement reference     Automatic end cover recognition can  be switched off with menu function   Recognition off   2 3 2      English Ee ee DISTO    prot   pro  a 1 0 0en    Using end covers  contd     In this case  the end cover has to be  manually selected in the submenu   End covers   2      CAUTIO
23.  deflects  the laser beam  The DISTO may  recive a signal that is too weak   error message 255     2  Aiming at a right angle  the DISTO  may receive a signal that is too  strong  error message 256      Inclined  round surfaces    Can be measured with the laser   Requirement  There is enough area  on the target surface for the laser  spot        252    PD    TCX             Free  handed aiming     approx  20   40 m     Use target plate 563875  DIN C6   rsp  723385  DIN A4  or    Make your own target plates of  any size        Scotch Cal     30   100 m   brown     Engineering Grade 3279   7502 99 61 036           Manufacturer  3MCompany  Measuring in the field  Attach the telescopic viewfinder  and    check it is engaged by applying  pressure from the side              PD Z55       Setting viewfinder    1  With menu function  permanent    1 4 2  place DISTO in Continuous  mode     2  Place indoors 5 m  10 m or  30 m from the wall     3  Attach alignment aid for telescopic  viewfinders to the wall as in  illustration below              DISTO    pro    prot a 1 0 0en       English    Measuring in the field  contd    Please copy diagram below  1 1   4  Focus cross hairs and laser dot by  slowly turning the eyepiece  adjustment screws        PD Z57    Telescopic    viewfinder  Pid                5  Align the telescopic viewfinder  with the laser point  side  height        Example  Positioned exactly 5m in  front of a wall       0 5 m   center the  laser dot beside the 5 m distance
24.  fulfill  the stringent requirements and  norms in combination with DISTO   Keep in mind the computer    manufacturer specifications on EMC     CAUTION    Interference caused by  electromagnetic radiation can result  in the tolerance limits for  measurements being exceeded   Although the DISTO meets the strict  regulations and standards which are  in force in this respect  Leica  Geosystems cannot completely  exclude the possibility that  interference may be caused to the  DISTO by very intensive  electromagnetic radiation  for  instance near radio transmitters   walkie talkies  diesel generators etc   Under such conditions  check  measurement results for their  plausibility     WARNING    Operating DISTO with one  end of a cable connected  e g   external feeder cable  interface  cable      can lead to exceeding the  electro magnetic emmission of  radiation and thereby causing  interference in other instruments     Precautions   While operating the DISTO  cables    must be connected at both ends  e g     instrument computer          FCC Statement  applic  in  U S      WARNING    his equipment has been  tested and found to comply with the  limits for a Class B digital device   pursuant to part 15 of the FCC  Rules    These limits are designed to provide  reasonable protection against  harmful interference in a residential  installation  Instruments of this kind  generate high frequency and may  radiate them  too     If not installed and used in  accordance with the instruction
25.  on  but the laser is not  operating    This mode is for making entries   carrying out calculations and calling  up menus        Pointing mode    DISTO is on  the laser is operating   Objects to be measured can be  pointed at in this mode     Measuring mode    DISTO is on and performs single or  continuous measurements  e g   minimum and maximum tracking   staking out  etc       DISTO    pro      pro  a 1 0 0en aes English    Instrument description                1    PD Z03  AUN    Oo      8  9                         Standard equipment    Carrying case with belt loop at  the back   Waistband   DISTO    prot   DISTO    pro  a  End cover with swivel foot  End cover with positioning  bracket alignment aid   Adapter end cover   CD ROM with interface software  and online documentation  User Manual   Quick Guide    10 Batteries  4 x 1 5V  AAA     Additional accessories can be found  under User Information           English    DISTO    pro    pro  a 1 0 0en    Basic instrument          Alphanumeric keypad   LED display   Measuring optics   Laser beam exit   Stand connection   End cover release button jen   Battery compartment cover   Sensors for automatic end cover   recognition   9 Magnetic plate for attaching  accessories   10 Interface slot cover    PD Z02    CONDOR WNM                    English       DISTO    pro    pro    a 1 0 0en    Display                        ABA    Port       PD Z04          Special symbols    Offset addition   subtraction   Lighting   Time delay rele
26.  on the currently selected  function     Input of numbers    Assigned text characters of the keys  are blocked     Key 1 pressed twice briefly enables     a minus sign to be input as the first    character     a decimal point to be placed after    having entered at least one number     A long press on the 0 key calls up  memory allocations for the input  values       Press 0 until a beep sounds   approx  1 sec   After release  the  contents of keypad memory 1 is  displayed       Press 0 until two beeps sound   approx  2 sec   After release  the  first memory contents of the stack is  displayed     Detailed information can be  E found in the section Menu  functions under  Memory      Text or data input in the data  memory    Brief repeated presses on the keys  displays the different layers of  assigned characters     Example  1 x key 2 A a  2 x key 2  B b  etc     Briefly press to switch  between capital   small  letters     English  z  a DISTO    prot   pro  a 1 0 0en    Keypad  contd   How to use instrument   to use instrument    After a long pause or by pressing  another key the cursor changes to    the next display    If one of the 0 9 keys are  E pressed for a long time  its  number appears on the screen     Press briefly to      finalize a computation and to  display the result      end a menu function and display  the result      confirm an input or setting      confirm a single measurement in the  menu function      jump from the menu to the selected  sub menu     Resu
27.  settings    4 basic functions  5 calculation             1 memory key 1 9    2 recall key 1 9  3 stack  4 data                DISTO has many ways of saving  measurements and computations     The last displayed measurement   computation or entry is saved when  DISTO is switched off and appears in  the basic settings when DISTO is  switched on again     Memory key 1   9  6 1     Nine memory places are allocated  with various in and output  possibilities to save intermediate  results or often used data   addition subtraction pivot gap  etc       The menu function only serves to  save data  Calling up saved data is  done with the menu function  recall  key 1   9   6 2      Default setting  After reset all  memory keys  3 4  are deleted     Precondition    Before saving the respective  measured or computed value must  be displayed in basic setting   Entries via keypad must be  confirmed with the Enter key     Saving with menu    After calling up this menu function  the following is displayed     English EET DISTO    pro    pro  a 1 0 0en    Memory  contd        memory key 1 9 6 1    TIE    0 000    9 129    The arrow in the symbol means  saving  the number beside it the  allocated memory key  1 9               Below in small fonts the current  memory contents is displayed or   0 000  if the memory key has not  been allocated  The current memory  content is overwritten when new data  is saved in that memory key     Select a  free  memory key  with the navigation keys or by    dire
28.  sign of the displayed measured  value changes     Example of a stake out   Constant a oo  1 75 m  Constant x issii 15m          A n  03  0 325m                   PD Z43             n  01   0 518m          v  A n  02  0 000m                   Variable  4 3 2   To stake out variable distances     After calling up the menu function  the following is displayed        variable 4 3 2  El  0000m  7 2 0 000m  3 3 0 000m     gt              Entry boxes     1 20 A maximum of 20 variable  distances can be staked off  one after the other     The first variable is already marked  in black on the display  Beside it the  most recently used distance value is  displayed     Enter variable distance  1     with the keypad  recall value  from keypad memory or from  the stack     Press briefly to confirm entry     The distance entered is displayed  beside the  1      Press navigation key to mark  the  2  variable distance  black     Enter the second and all other varia   bles as described    The first of the following no longer  needed variables is to be set to  0      Press briefly to change into  the measuring mode and  start stake out     Point laser at target     Stake out procedures and displays of  the DISTO correspond with the  previously described menu function   Constants   4 3 1         English       DISTO    pro    pro  a 1 0 0en    Basic functions  contd   Pythagoras  4 4     Using this menu function distances  not accessible for the DISTO can be  computed indirectly     Examples    
29.  the  battery compartment      Always replace the entire set of  batteries  Never mix old and new  ones      Never use batteries made by diffe   rent manufacturers or batteries of  different type     4  Replace battery cover     5  Place end cover in slot and push  in until it locks                    Switching on DISTO       PD Z10      ON       QD    oM             English    1 Deutsch  s ETIN             Press briefly     DISTO is on and in nomal mode   The display shows the basic settings  with the last mesured value        4   fs       3 504m             Switching on DISTO for the first  time    When following the described  procedure  the language selection  menu is displayed first     Select desired language with    these keys     A horizontal bar marks the selection     A brief press confirms the  selection     After a  Thank you  text  the basic  settings display appears     Language selection can be changed  at any later time in menu  Language    3 2      It is possible to load an additional  fourth language via the DISTO  interface     Any further language loaded via the  interface after the fourth one   automatically replaces that fourth  loaded language     Read instructions for the DISTO  Online Software on the CD ROM  supplied     Switching on Pointing mode    Briefly press     DISTO changes from Nomal mode  into Pointing mode and the laser  lights up     This symbol appears in the  basic settings display while  the laser is on     If within 30 seconds no measu
30.  the possibility of a  E shaky measurement in the  Pointing mode either     use the time delay release  x key     or press the trigger key long enough  to start minimum tracking     Briefly press trigger key again as  soon as the measurement in  minimum tracking is done     Press briefly to confirm  displayed value     English    Calculation  contd        space 5 7    iat 4 563m  4 563m          space 5 7   EE     5  E Jv  GE 258m  imn 4  105 344m              The room length is displayed beside   the corresponding number  1     At the same time the next width to be  measured is marked in black with the  corresponding number  2      Measure width of the room as  described earlier and confirm with  Enter key    Then measure room heigth  no  3   and confirm     Press again briefly to start  computation     The results of the computations are  explained with graphics and are  numbered in sequence  1 4    onsite ceiling   floor area  ides surface area  circumference                  volume       Should all results be saved to data  memory     Press and hold     After saving  the menu function is  terminated and basic settings  displayed     Should only a certain result be used     Select desired result with    navigation keys   g y    Press briefly to confirm  selection     Menu function is terminated and the  marked result displayed in basic  settings     If desired save result to keypad or  data memory     Memory  6      5x       menu    1 measure settings  2 end cover  3 basic
31.  this device must accept  any interference received   including interference that may  cause undesired operation                    DISTO    pro    pro  a 1 0 0en 257 on English    Care and Storage   and Storage    Care    em Clean and dry      Blow away dust from lenses      Do not touch glass with fingers      Only clean with a soft cloth  if  necessary  damp with pure alcohol   Do not use other cleaning agents   Plastic parts could be affected     Wipe off splashes of cement  plaster  etc  as quickly as possible  using  water and a damp cloth or sponge   Look after the optical surfaces with  the same care that you would apply  to spectacles  cameras and field  glasses     Storage    Please respect the  E temperature limits  specially  during summer when storing the  equipment inside a vehicle    40  C to  70  C    40  F to  158  F        Unpack instruments and   accessories that have  become wet  Dry off the instrument   container and accessories  at  maximum 40   C   108   F  and clean   Only repack the equipment when it is  completely dry     After longer periods of  E storage or transport carry out  a check measurement before using  the equipment     If the indoor and outdoor  temperatures are very different  allow  time for the instrument to adapt    If the DISTO is removed from an air   conditioned room and exposed to  warm damp air  the instrument and  the optics will fog over  To reduce  this effect  cover the instrument with  a cloth and allow it to adapt slowly to
32.  when a stand is used with the  adapter end cover     To adjust rear reference  the distance  from the rear side of the adapter end  cover to the rotation axis of the stand  has to be entered       For stand SLIK U9000   recommended for use with  DISTO  this distance is0 054 m     After calling up the menu function   the following is displayed        pivot gap 2 2 4             0 000m    The last saved entry for the pivot gap  between adapter end cover and the  rotation axis of the stand is  displayed        Enter new pivot gap with keypad   recall value from keypad memory or  from the stack    Brief press confirms entry   Renewed press quits menu     A short confirmation is displayed and  the DISTO changes to Normal mode     DISTO    pro      pro  a 1 0 0en BENE ONE English    End covers  contd      m Distances entered are only  considered  when measuring  reference is set to rear     Individual extension  2 2 5    Menu function mean for add ons that  are customer specified or for  extensions to adapter end covers     To adjust the rear reference  the  distance from the adapter end cover  to the locating surface of the  customer specified add on has to be  entered     It is possible to enter negati   E ve values     After calling up the menu function the  following is displayed        individual extension 2 2 5    i    0 000m             The most recently entered distance  between adapter end cover and the  individual extension is displayed     Enter new distance with the ke
33. English       DISTO    pro    pro  a 1 0 0en    Calculation  contd     If there is the possibility of a  E shaky measurement in the  Pointing mode either     use the time delay release  x key     or press the trigger key long enough  to start tracking     Press briefly to confirm  displayed value        trapeze HSD 5 4    1 3 516m  c  3    3 516m             The first measured value appears  beside the corresponding number   1   At the same time the base side  of the trapezium to be measured is  marked in black with the  corresponding number  2      Measure base length of trapezium as  described earlier and confirm with  Enter key     Pressing and holding trigger key in  Pointing mode starts tracking        trapeze HSD 54  1 3 516m  2 5 373m    9 9  3m             The second measured value appears  beside the corresponding number  2   At the same time the digonal to be  measured next is marked in black  with the corresponding number  3      Measure diagonal of the trapezium  as described earlier and confirm with  Enter key     Pressing and holding trigger key in  Pointing mode starts maximum  tracking     Each of the displayed  E measured values can be  selected with the navigation key  again and corrected by a new  measurement     Press briefly again to start  computation after confirming  last measurement         trapeze HSD 5 4    lt A    6996m     2 39 8    30 932m     aa             Should all results be saved to the  data memory     Press and hold     After saving  the 
34. N    Strong magnetic fields can  influence end cover recognition and  cause measuring errors   Precautions    Measurements near magnetic fields   e g  magnets  transformers    should  be done with the automatic end  cover recognition switched off and  measuring has to be monitored  carefully     Changing end covers    The procedure for changing end  covers is the same for all types     1  Press release button and pull off  end cover        PD Z06                When using the end cover  E with positioning bracket    alignment aid the release button is  only accessible through the recess in  the end cover        PD Z23             If the menu function  no end cover    2 1  is not selected  then as soon as  a measurement is tried without an  end cover  a message is displayed        choose the  g end cover      DISTO             2  Select and place an end cover in  the slot of the casing and push it  down until it locks        PD Z09                3  A short confirmation is displayed  and then the basic mode  The  DISTO is ready for measurement     CAUTION    Wrong measurements after  changing end covers   Precautions   Please make a control measurement  every time after changing end  covers     For measurements without end cover  please enter the menu function  no  end cover   2 1  after removing the  end cover     Avoid using DISTO without  E end cover  as this will leave  the battery cover exposed and prone  to being damaged     Measuring from flat planes    For stable measu
35. RNING    The absence of instruction  or  the inadequate imparting of  instruction  can lead to incorrect or  prohibited use  and can give rise to    accidents with far reaching human   material  financial and environmental  consequences    Precautions    All users must follow the safety  instructions given by the  manufacturer and the directions of  the person responsible for the  instrument     CAUTION    Watch out for erroneous  distance measurements if the  instrument is defective or if it has  been dropped or has been misused  or modified  e g changing the end  cover     Precautions    Carry out periodic test measurements   Particularly after the instrument has  been subject to abnormal use  before   during and after important  measurements and after changing end  covers  Keep optical lenses clean and  check for mechanical damage to the  DISTO     CAUTION    Take care when aiming the  DISTO directly into the sun  The  receiver lens acts as a magnifying  glass and can thus cause damage to  the instrument internals     Precautions   Do not aim the DISTO directly at the  sun    WARNING    Insufficient securing or  marking of your measurement site  could cause a dangerous situation  on the public highway  building site   or in the factory etc    Precautions    Always ensure your measurement  site is appropriately secured  Obey  the local accident prevention  regulations  and road safety rules  at  all times     CAUTION    In using the instrument to  measure distances or movin
36. ase   Beep on   off   Battery full   empty   Laser active   Measurement reference  front    stand  rear    8 DISTO without detected end  cover   9 DISTO without end cover  menu  setting    10 End cover with swivel foot   11 End cover with positioning  bracket alignment aid   12 Adapter end cover without  attachments   13 Adapter end cover with stand   14 Adapter end cover with free end   15 Adapter end cover with short  bracket  723775    16 Adapter end cover with long  bracket  723776    17 Contact service centre   18 Error message    NOOB WDM      English ENTE DISTO    prot   pro  a 1 0 0en    Keypad    Overview Table of characters       Key assigned characters    PD Z05    CR E  s  u njofefj  fnfol  folo e   mfjnfofef  faf  olofolo e   7  rjoflr si7               efjaoflrfsi                s j riu vjsejo U0 0 0         a  o wix vizio        j       elella v qp spo up d 3                            1 Menu key 6 Plus   navigation key  This table contains all displayable ee The symbols on the keys are  2 Power on and measuring key up characters that can be entered limited to the most commonly  3 Multiplication   time delay release 7 Minus   navigation key  through the keypad  used characters  due to the lack of   4 Clear key down space    5 Alphanumeric keypad 0 9 8 Result   Enter key    DISTO    pro    pro  a 1 0 0en a es English    Keypad  contd   Menu key    To call up the main menu     After entering a numeric value  through the keypad   multiple   presses on the menu key
37. ation    The DISTO produces a visible laser   beam which emerges from the front   of the instrument    It is a Class 2 laser product in   accordance with       EC60825 1  1993  Radiation safety  of laser products      EN60825 1  1994  Radiation safety  of laser products     It is a Class Il laser product in   accordance with      FDA 21CFR Ch I  1040  1988  US  Department of Health and Human  Service  Code of Federal  Regulations     Laser Classification  contd     Laser Class 2 II products    Do not stare into the laser beam or  direct it towards other people  unnecessarily  Eye protection is  normally afforded by aversion  responses including the blink reflex     Labelling       0 95mW  620 690nm  EN60825 1 1994  IECB0825 1 1993    Maximum radiant power      Emitted wavelength      Standard applied        WARNING    Looking directly into the beam  with optical aids  e g  binoculars   telescopes  can be hazardous   Precautions    Do not look directly into the beam  with optical aids     Laser beam       CAUTION    Looking directly into the laser  can be hazardous to the eye   Precautions    Do not look into the laser beam   Make sure the laser beam is aimed  below or above eye level  especially  with fixed installations  machines   etc       PD Z47          Pulse duration 15 x 10  s  Maximum radiant power 10 95 mW    Maximum radiant  power per pulse 8 mW  Measurement  5   uncertainty   CAUTION    Allow only authorized Leica    Geosystems service workshops to  service the ins
38. ch of the displayed  Eg measured values can be    selected with the navigation key  again and corrected by a new  measurement     Press briefly again to start  computation after confirming  last measurement         trapeze HSH 533    lt A    34108m   c 2 31 0    12 096m     ad             Should all results be saved to the  data memory     Press and hold     After saving  the menu function is  terminated and basic settings  displayed     Should only a certain result be used     Select desired result with    navigation keys     Press briefly to confirm  selection     Menu function is terminated and the  marked result displayed in basic  settings     If desired save result to keypad or  data memory     Trapezium HSD  5 4     After measuring the height  the base   length and the diagonal  HSD  of a   trapezium  this menu function   computes     the length and the slope of a side of  the trapezium      the area of the trapezium        PD Z67                This menu function has the  advantage that all measurements  can be made from the same location     After calling up the menu function   the following is displayed        trapeze HSD 54    Cl    The first height to be measured  rain  gutter height  and the corresponding  number  1  are marked in black     DIST     Aim laser at the first point to be  measured              Press briefly to change into  Pointing mode     Always measure the shorter  E of the two trapezium sides     Trigger measurement  Hold  W  DISTO steady        
39. ctly entering the memory  key number     Press briefly to save     After a short confirmation  basic  setting are displayed     DISTO    pro      pro  a 1 0 0en a English    Saving with short cut    0o 0 0 0 5    Enter short cut for  memory key    6 1  and add the number of the  desired memory allocation  1   9       Press briefly to call up main  menu     After confirmation of saving the basic  settings are displayed     Saving with memory key  Data is allocated to each memory  key from 1 to 9     o Press and hold desired key   e g  key 3 for memory key 3         memory key 1 9 6 1    TIE    0 000    9 723             The corresponding memory key is  displayed     Press briefly to save     After a short confirmation the basic  settings are displayed     Recall key 1 9  6 2     This menu function only serves to  recall one of the nine memory keys   Saving data in a memory key is done  in the menu function  Memory key 1   9   6 1      When called up  the value in the  basic settings is replaced by the  contents of a memory key     Recall with menu  After calling up the menu function   the following is displayed        recall key 1 9 6 2    TIE          0 000       The arrow in the symbol means  recalling  the number beside it the  allocated memory key  1   9      Below the current memory contents  is displayed or  0 000   if the  memory key is not being used     Select memory key with  navigation keys or select  directly via keypad entry     Press briefly to recall  contents  
40. d     As soon as the measurement is done    in tracking mode  press trigger key  again briefly     Press briefly to confirm  displayed value        triangle SSS 5 1  1 3 118m    ZNB          3 118m       The first measured value appears  beside the corresponding number   1   At the same time the second  side of the triangle to be measured is  marked in black with the  corresponding number  2      Measure the second and third side of  the triangle as described     Each of the three displayed  E measured values can be  selected again with the navigation  key and corrected by a new  measurement     After confirming the last  measurement press briefly to       start computation   triangle SSS 5 1  AN    2 379m  PC EA  4 003m     a              Should all results be saved to the  data memory     Press and hold     After saving the menu function is  terminated and the basic settings are  displayed    Should only a certain result be used   Select desired result with    navigation key     Press briefly to confirm  selection     Menu function is terminated and the  marked result displayed in basic  settings    If desired save result to keypad or  data memory     Triangle SH  5 2     After measureing the basic side and  height  SH  of a triangle the menu  function computes the area of the  triangle     After calling up this menu function   the following is displayed        triangle SH 5 2    ZNB    2             For the first measurement the base  side and the corresponding number   1 
41. e g  3 500m      x  Multiplication    Measurement  e g  8 375m     Area  e g  29 313m         PD Z39                   Measurement x measurement x  measurement   volume    Measurement  e g  3 500m     e Multiplication    Measurement  e g  8 375m     eo Multiplication    Measurements  e g  2 285m       Volume  e g  66 980m         PD Z40                  The volume can also be  computed following an area  calculation     Menu functions are described in the  sequence of their appearance on the  DISTO display  i e  in an ascending  order of their respective short cut  numbers     The short cut numers are listed in  brackets behind the menu function     How to use the menus is explained    in section  How to use the  instruments  under  Using menus       E The short cut numbers    facilitate searching for menu  functions     Measurement settings  1        menu    1 measure settings    2 end cover  3 basic settings    4 basic functions  5 calculation  6 memory                   measure settings 1    1 reference    2 offset    3 timer  4 laser  5 tracking                Measurement reference  1 1        reference 1 1    1 front  2 stand             Set measurement reference for the  DISTO  showing where measure   ments will be made from    The set measurement reference is  used for all following measurements  until the it is changed again     Basic setting  Rear  1 1 3        English       DISTO    pro    pro  a 1 0 0en    Measurement settings  contd     The measurement reference s
42. elay can also be set in the  Pointing mode     Keep pressed  until the  desired delay is reached     The uppermost line displays the  symbol of the time delay release with  the delay below it     Upon release the remainig seconds  to the measurement is displayed   e g  59  58  57        The last 5 seconds are counted  down with a beep sound  After the  last beep the measurement takes  place and the measured value is  displayed     DISTO    pro      pro  a 1 0 0en fo 23 English    Permanent  1 3 2   After calling up this menu function   the following is displayed        permanent 1 3 2       10sec             The suggested delay is for all  following measurements and can be  changed as follows     With the navigation keys   Each key press increases    respectively decreases delay  by 1 second     Q9 With a keypad entry     As long as this key is  pressed the delay increases  until the maximum of 60  seconds is reached     After a brief press on the Enter key a  confirmation appears and the menu  function is terminated     The DISTO changes into Normal  mode and displays the symbol of the  time delay release in basic settings     None  1 3 3    After pressing the Enter key the  permanent delay is deleted and the  menu function terminated     Laser  1 4        laser 14    1 normal mode    2 permanent             Here the operational mode of the  laser is set     Normal mode  The laser switches off  automatically after 30 seconds     Permanent mode  The laser remains  on in Point
43. ersicd  veat  Accessories for measurements        Accessories for data interface         cccccsscssesssssecsesssssssesssstssessessssnsssssssnsssssensensens   Transport aCCeSsOrlGs        22  aset rre ctittecet tremere Forte mentre eat       Safety Instructions                      eeeeeeenetene tentent tnntnntnntnntnnenns 53  Use of the InStEUITight sa ccscccscietsscsasssatcscteteresasssatescteuaresavesstsvereserssotesetesorsdetststesetesorssersss 53  Permitted USS E   Prohibited uses   m  LIMIS TO USE E                             iletin     Areas  of Responsibility          1   5 2     teet nvidia ana breed rte etaed 54  Hazards in Use i    Important hazards in  S8    aene repetere ttetnte rtc berrendel etui pepte 54  Laser Classification siscsaicsaccscssssscsaressscscrsuascsnssusscsetetaresonenstesonesstesotcnstesonsvetessteastessnsnettes 55   Labelling m  DISTO with Telescopic Viewfinder                           sss 56  Electromagnetic Compatibility  EMC                         sees 56  FCG Statement  applic  in U S               siiis 57             Care and Storage    neret tnter be intet etn rade n rne 58                         Clean and dry fe  Sici                                                      lC m                                   E  Bi                                                    Technical Data        cssscssssssssssssessessessssseesssssesessesssesessesssssesseesseanssessssatentenseanes  Remarks on Measuring Accuracy         seescecesseeseesessessees
44. escribed  previously    Pressing and holding the trigger key  starts tracking        height 4 5    14 11 454m  A 2 8762m  8 762m    The second measured value appears  beside the corresponding number   2   At the same time the last to be  measured side of the triangle with  the corresponding  3  is displayed in  black              Align DISTO approximately at a right  angle with the reference  wall    Where the measured points were  arranged vertically  it would  correspond to the horizontal setting  of the DISTO     Press briefly to change into  Pointing mode     Press until minimum tracking  starts     Move laser dot up and down and  crosswise along the extension of the  desired measuring distance until the  minimum distance can be determined        DISTO    pro    pro    a 1 0 0en       English       Basic functions  contd     DIST     Press briefly to confirm  displayed measured value     Press briefly to end minimum  tracking        height 4 5  1 11 454m   Z 2 8 762m  8 515m       0 515m          The third measured value appears  beside the corresponding number   3     Each of the three displayed  E measured values can be  selected again with the navigation  key and corrected by a new  measurement     Press briefly to compute and  display the disired distance        height 4 5    Z 4 5 595m             Press briefly again to quit  menu and display the result    in the basic settings     If desired save result to the keypad  or data memory     Accuracy  4 6     This menu f
45. ese distances can be  checked  staked out or marked     Application examples      Saving the distances between  rafters and wooden beams in the  DISTO  As a result  the parts can be  exactly positioning on the  construction site using the DISTO      Saving distances of complete  developments of walls to the DISTO  and check on the site      Saving panel sizes in the DISTO  and recalling those values during  panelling     These examples also show  E how to facilitate procedures  of checking constructions                       English       DISTO    pro    pro  a 1 0 0en    Basic functions  contd     Constant  4 3 1   To stake out contant distances     After calling up this menu function   the following is displayed                 constant 4 3 1  a B 0000m  x 0 000m  X  X   A  Entry boxes     a Distance at which stake out  starts     X Constant distance which can be  used for stake out one by one  several times        The number of stake outs is  l only limited by the maximum  measuring range     The letter  a  is already displayed in  black  Beside it the most recently  used distance value   x   is  displayed     o Enter new distance  a  with  the keypad  recall value from  keypad memory or stack     Press briefly to confirm entry     The entered distance is displayed  beside the  a      Press navigation key to mark  the constant  x  black     Enter constant  x  with the    keypad  recall value from  keypad memory or stack     The entered distance is displayed  beside the  x 
46. firm with  Enter key     Pressing and holding trigger key in  Pointing mode starts tracking        gable area 5 5  1 3 547m    AN 2 9812m    9 812m             The second measured value appears  beside the corresponding number   2     At the same time the next height to  be measured  roof ridge  is marked  in black with the corresponding  number  3      Press briefly to change into  Pointing mode     Aim the laser at the first bottom side     Trigger measurement  Hold  DISTO steady     Pressing and holding trigger key in  Pointing mode starts maximum  tracking    Briefly press trigger key again when  measurement is done     Press briefly to confirm  displayed value     Each of the three displayed  E measured values can be  selected with the navigation key  again and corrected by a new  measurement     After confirmimg the last  measurement  press briefly to  start computation        gable area 5 5    dh    789m             Briefly press again to quit  menu and to display the  marked result in basic  settings     If desired  save result to keypad or  data memory     Circle  5 6     This menu function computes the  area of a circle using the diameter        English       DISTO    pro    pro  a 1 0 0en    Calculation  contd     Application     For volumes of trees  silos  etc     admeasurements in pipe systems     After calling up this menu function  the following is displayed        circle 5 6     Ya             The diameter of the circle and the  corresponding number  1  are  
47. g objects   e g  cranes  buiding machines   platforms       unforeseen events can  lead to errors in measuring   Precautions    Only use this instrument as a  measuring sensor and not as a  control unit     English   54 DISTO    pro    pro  a 1 0 0en    Hazards in Use  contd     Your system has to be designed and  operated in such a way  that it is  secured  e g  terminal safety switch   against damage due to error in  measurements  defects on the  instrument or power interruptions     CAUTION    Strong magnetic fields in the  measuring environment can  influence automatic end cover  recognition and lead to errors while  measuring    Precautions    When measuring near magnetic  fields  e g  magnets  transformer  stations      DISTO automatic end  cover recognition should be  monitored or switched off     WARNING    If the product is used together  with computers which have not been  approved by the manufacturer for  use in the field  there is a danger of  electric shock    Precautions    Follow the directions given by the  manufacturer for using computer  equipment in the field with our  systems     DISTO    pro      pro  a 1 0 0en aa English    CAUTION    On sending the instrument  or  on the disposal of batteries that are  not fully discharged  a fire could be  caused by improper treatment   Precautions    Remove the batteries from their  compartment before sending the  instrument  Dispose of batteries only  if they are completely discharged   operate the instrument in trac
48. ing mode as long as the  DISTO is on     Default setting  normal  1 4 1     Normal mode  1 4 1    After pressing the Enter key the  menu funtion is terminated and  basic settings are displayed       This symbol appears in basic  settings as long as the laser  is on     Permanent  1 4 2    After pressing the Enter key the  menu is terminated and basic  settings are displayed and the Per   manent mode is started     Every press on the On and  measurement key immediately  triggers a measurement     This symbol is permanently  displayed in basic settings     Only activate permanent  E mode of laser if required as it  uses up battery power very rapidly     Measurement settings  contd        Tracking  1 5   tracking 1 5  1 on          Tracking for the DISTO is selectable  in this submenu        This function permits moving objects  to be measured and stake outs  placed to a fixed object     Default setting  off  1 5 2     On  1 5 1    After pressing the Enter key  a short  confirmation appears and the menu  function is terminated     DISTO changes to Normal mode and  displays the basic settings with   Track  appearing in the uppermost  line     Tracking is started by pressing the  trigger key twice    The lowest line displays the  continuously updated measured  value     A brief press on the trigger key ends  tracking  The most recent measured  value can now be saved or used in a  computation     Frequent and long tracking  E uses up battery power very  rapidly     Off  1 5 2    Af
49. ing the keypad  a text of maximum  30 characters can be entered    The text is displayed in three lines   but transmitted as one line via the  data interface        text 6 4 1    401 yw             Press briefly to change  between small and capital  letters      1  Repeatedly press    corresponding key to call up  the desired special character    described in section   Keypad  under  Text and  data input       Wait with next input until the  E cursor has moved a position  further     Press briefly for  space    Press and hold to enter the  number  0         Press briefly  to move back  one space and overwrite the  last entry   Repeat above process to  delete entries step by step     Press briefly to end and save  text input     After a confirmation  the basic  settings are displayed     The menu function Send  6 4 5    enables the saved data to be  transmitted to a PC and displayed in  an Excel sheet     Store  6 4 2  jen  Menu function to store measured and  computed values into the data   memory     Store with menu  Precondition  The value to be stored  is displayed in basic settings     After calling up the menu function   the next free memory location is       displayed   store 6 4 2     Gil 002        gt  E    2 493    Additionally  a three line text with a  maximum length of 8 characters per  line  can be entered using the  keypad              DISTO    pro    pro  a 1 0 0en   ay English    Memory  contd     By clearly describing stored  E values  misunderstandings  and 
50. it shortens  battery life     Off  3 5 2   Switches off display lighting     After pressing the Enter key     the menu function is terminated     a confirmation is displayed      basic settings are displayed     Switch off  3 6     This menu function switches the  DISTO off     Pressing the Enter key is  acknowledged by a beep  Then the  DISTO switches off       Under  Switching off DISTO   further possibilities to switch  off the DISTO are described     Basic functions  4     o          menu    1 measure settings  2 end cover  3 basic settings    4 basic functions    5 calculation  6 memory             basic settings 4    1 maximumtrac    2 minimumtrac  3 required distance                Maximum tracking  4 1     Maximum distance measurement is  done by using maximum tracking        PD Z20                Application examples      measuring room diagonals      maximum measures on rough or  wavy grounds      maximum measures in large halls      roof  ridge heights from below the  facade      in general  where access is difficult  or under poor lighting conditions   drainages  shafts  etc      After selecting this menu function     the laser lights up in the Pointing  mode      the following is displayed        maximumtrac 4 1             Press briefly to start tracking     As with the room diagonal      aim DISTO first at a point near the  opposite corner      then move the beam slowly across  the corner     E continuously takes single  measurements     The furthest distance i
51. ity Mana   gement and Quality Systems  ISO  standard 9001  and Environmental  Management Systems  ISO  standard 14001      TOIVI    ISO 9001 150 14001    Total Quality Management    Our commitment to total customer  satisfaction    Ask your local Leica Geosystems  agent for more information about our  TQM program     English   62   DISTO    pro    pro  a 1 0 0en    
52. king  mode  until batteries are completely  discharged      CAUTION    If you do not intend using the  instrument for a long time  the  batteries may leak and damage the  equipment    Precautions    Remove batteries if you are not  going to use the instrument for an  extended period     CAUTION    Safety measures could be  voided  persons hurt if the instrument  is not used as intended e g  it could  be damaged mechanically  e g   being dropped  tossed against other  objects     or damaged by inproperly  installing add ons and attachments     Precautions    Make sure accesories  e g  telescopic  viewfinders  hand loops  shoulder  straps      are properly attached and  locked in place  Protect your    instrument from mechanical damage     CAUTION   If the equipment is improperly  disposed of  the following can happen       If plastic parts are burnt   poisonous gases are produced  which may impair health       f batteries are damaged or  overheated  they can explode and  cause poisoning  burning   corrosion or environmental  contamination      By disposing of the equipment  irresponsibly you may enable  unauthorized persons to use it in  contravention of the regulations   exposing themselves and third  parties to the risk of severe injury  and contaminating the environment     Precautions    Dispose of the equipment  appropriately in accordance with the  regulations in force in your country   Always prevent access to the  equipment by unauthorized personnel     Laser Classific
53. llowing  measurements      is automatically suggested at the  next menu function call up     Off  1 2 3    Deletes an existing addition or  subtraction    After a brief press on the Enter key a  confirmation appears and the menu  is quit     The DISTO changes into Normal  mode and displays the basic  settings     Time delay release  1 3   Sets time delay between 5   60    seconds after pressing the trigger  key to the start of the measurement        timer 1 3    1 once  2 permanent  3 none             Default setting  None  1 3 3     The time delay release permits using  the DISTO in measuring situations  where the keypad is hard to reach     z This symbol appears in the  uppermost line of the basic  settings when the time delay  release is in use     Once  1 3 1   After calling up the menu function   the following is displayed        once 1 3 1          10sec    The suggested delay is only for the  next single measurement and can be  changed as follows           With the navigation keys   Each key press increses   respectively deceases delay  by 1 second     Q9 With a keypad entry           As long as this key is  pressed the delay increases  until the maximum of 60  seconds is reached        English       DISTO    pro    pro  a 1 0 0en    Measurement settings  contd     After a brief press on the Enter key a  confirmation appears and the menu  is terminated     The DISTO changes into Normal  mode and displays the symbol of the  time delay release in basic settings     The d
54. lt         Enter key      Press and hold to save a   value into the data memory   With menu functions  all results are  saved in sequence to the data  memory     Plus   navigation key  up      Minus   navigation key   down     Press respective keys briefly in   normal mode to      enter an addition or subtraction in a  computation     move up or down from one entry to  the next in menus     Press respective keys briefly in  Pointing mode to change  measurement reference       Press both keys     simultaneously to turn  DISTO off in Normal and  Pointing mode     Or as an alternative  press  E and hold one of the keys and  then press the other     For a first time use  insert new  batteries into the DISTO  for battery  type read the technical data sheet      C This symbol appears in the  display as soon as the  battaries are empty and need  to be replaced     Eg When changing batteries  the   settings and saved measured  values remain unchanged in the data  memory     Inserting   replacing the  batteries  1  Press end cover release button     and pull the end cover off the  instrument                    2  Press both locking clips together  with fingertips and pull out battery  cover                 3  Remove empty batteries  if any  Fit  new batteries the right way round        PD Z08                      DISTO    pro    pro  a 1 0 0en       English       Insert   replace batteries  contd     eu IMPORTANT       The proper way of inserting the  batteries is shown on the side of
55. marked in black     Press briefly to change into  Pointing mode     Position DISTO on the circumference  of the circle as reference     Aim laser dot at a spot at the other  side of the circle  e g  ground         DISTO    pro    pro    a 1 0 0en    Trigger measurement  Hold  DISTO steady     If there is the possibility of a  E shaky measurement in the  Pointing mode either     use the time delay release  x key     or press the trigger key long enough  to start maximum tracking     Briefly press trigger key again as  soon as the measurement in  maximum tracking is done     Press twice to confirm  measurement value and to  start computation        circle 5 6    e    0 250m              Briefly press again to quit  menu and to display result in  basic settings     If desired  save result to keypad or  data memory     Space  5 7     This menu function computes from  lenght  width and height of a room    floor and ceiling area      sum of the wall areas      circumference      room volume     Application      Room dimensions are required by  craftsmen for painting  plastering   carpeting  etc     After calling up this menu function  the following is displayed        Space 5 7       Ep   3                For the first measurement the room  length and the corresponding  number  1  are marked in black     Press briefly to change into  Pointing mode     Align DISTO and aim with laser at  the first point to be measured     Trigger measurement  Hold  XJ     DISTO steady     If there is
56. memory  location in the stack is empty     The most recent  current  entry is  always in memory location 1  the  second to last entry in memory  location 2  etc     Select memory key with  navigation keys or select  directly via keypad entry     Press briefly to recall  contents     After a short confirmation the  memory contents is displayed in  basic settings     The results of individual  Eg measurements for basic  functions  Pythagoras  heights  or  computations  triangles  trapeziums   etc   can be recalled from the stack  and used for further calculations     Recall with 0 key    Press and hold key for about  2 seconds until two beep  sounds are audiable     If the key is pressed for too  short a period then the  memory key is displayed  6 2         stack 6 3          1 891       English   46   DISTO    pro    pro  a 1 0 0en    Memory  contd     The first memory location of the  stack is displayed     Select desired memory  location with the navigation   keys or by direct keypad  entry     Press briefly to call up  content     After a short confirmation  the  memory content is displayed in  basic settings     Data  6 4        data 6 4                This submenu manages data  memory     Default settings  none  meaning that  a reset  3 4  does not delete the  data memory     Text  6 4 1    This menu function is used to enter  text in the data memory  e g  to  document measurements     After calling up this menu function  the next free memory location is  displayed     Us
57. memory location     D  amp     Enter the first and the last    memory location and then  one after the other the    selected memory location    numbers of the memory area     Press briefly to confirm  selection and to start data  transfer     D    English    During transmission  the number of  the current data memory location    being transmitted from is displayed     At the end of the transmission the  submenu is displayed again     Calculator  7     o c       menu    2 end cover  3 basic settings  4 basic functions    5 calculation    6 v                   calculator 7  2x  3 square root             The calculation functions in this  submenu supplement the four funda   mental rules of arithmetics as  described in section  Simple  calculations      ez If the wrong measuring units  are used the following error   message appears      Area and volume dimensions cannot  be squared      From lengths or volume dimensions  no square roots can be calculated   etc     Division  7 1    Precondition  The first value to be  calculated with has to appear in the  basic settings    Each entry with the keypad has to be  confirmed with the Enter key     After calling up the menu function the  following is displayed          13 510m                The first value to be calculated with  is displayed in small font size     The second number may be     entered with the keypad      recalled from memory key or from  the stack      determined by a distance  measurement     Press briefly to compute 
58. menu function is  terminated and basic settings  displayed     Should only a certain result be used   Select desired result with    navigation keys   g y    Press briefly to confirm  selection     Menu function is terminated and the  marked result displayed in basic  settings     If desired save result to keypad or  data memory     Gable area  5 5     This menu function computes the  gable area of a facade with  symetrical pitch roof     Application   With the gable area the modified  room can be determined        PD Z68             After calling up the menu function   the following is displayed        DISTO    pro    pro  a 1 0 0en       English    Calculation  contd        gable area 5 5     Y          gable area 5 5    1 3 547m  in   3    3 547m             The first height to be measured  rain  gutter height  and the corresponding  number  1  are marked in black    Press briefly to change into  Pointing mode     Aim laser at the first point to be  measured     Trigger measurement  Hold  X  DISTO steady     If there is the possibility of a  E shaky measurement in the  Pointing mode either     use the time delay release  x key     or press the trigger key long enough  to start tracking     Press briefly to confirm  displayed value     The first measured value appears  beside the corresponding number   1   At the same time the next gable  width to be measured is marked in  black with the corresponding number  727     Measure gable or house width as  described earlier and con
59. mode and  displays the selected language in the  basic settings     Beep  3 3        beep 3 3    1 measure    3 off             Set a beep to sound for keypresses  and   or when measurements are  being made     4     Beep on   off    One of these symbols will be  displayed after switching the DISTO  on    While the symbol for  Beep on   disappears subsequently the symbol  for  Beep off  remains permanently  displayed     Default setting  key  3 3 2     Measure  3 3 1   Every measurement made is  confirmed with a beep     Key  3 3 2   Every key press is confirmed  accustically     Off  3 3 3   Beep is switched off     Error messages and  E switching off the DISTO are    always accompanied by a beep     Reset  3 4     Resets customer settings of the  DISTO to basic settings     After pressing the Enter key    reset is done immediately     a short confirmation is displayed     the menu function is terminated     DISTO changes into Normal mode  and displays basic settings        Lighting  3 5   lighting 3 5  1 on             This submenu is used to switch  lighting on or off     Default setting  off  3 5 2    On  3 5 1    Switches display lighting on    After pressing the Enter key a short    confirmation appears and the menu  function is terminated        English       DISTO    prot   pro  a 1 0 0en    DISTO changes into Normal mode  and displays the lit basic settings     x This symbol appears in the  upper most line of basic  settings     Only use lighting when  E required as 
60. nd  rear    addition  subtraction  none    once  permanent  none    normal mode  permanent    1 5 tracking    1 5 1   1 5 2   1 6 send  1 6 1   1 6 2   1 6 3   2 end cover    on  off    on  only results  off    2 1 without end cover  2 2 adapter end cover    2 2 1  2 2 2  2 2 3  2 24  2 2 5    without add on    accessory723775  accessory 723776    pivot gap    individual extension    2 3    recognition  2 3 1 on  2 3 2 off     2 4 rotating foot    2 5 aligning end   3 basic settings    3 1    32    3 3    34    3 5    3 6    units   3 1 1 0 000 m  3 1 2 0 00m  3 1 3 0 00 feet  3 1 4 0 00  32  3 1 5 0 0 in  3 1 6 0  32  language   3 2 1 German  3 2 2 English  3 2 8 French  beep   3 3 1 measure  3 3 2 key  3 3 3 off  reset   lighting   3 5 1 on  3 5 2 off  Switch off    4 basic functions    4 1  4 2  4 3    maximumtrac  minimumtrac    required distance    4 3 1 constant  4 3 2 variable    4 4 pythagoras    4 5 height    4 6 accuracy  4 7 average    5 calculation    5 1 triangle SSS  5 2 triangle SH  5 3 trapeze HSH  5  trapeze HSD  5 5 gable area    5 6 circle    5 7 space    6 memory    6 1 memory key 1 9  6 2 recall key 1 9    6 3 stack  6 4 data  6 4 1  6 4 2  6 4 3  6 4 4  6 4 5    7 calculator    text   store   change   erase   send   6 4 5 1 all  6 4 5 2  position    7 1  division    72 x2    7 3 square root    TOM    Leica Geosystems AG  Heerbrugg   Switzerland has been certified as  being equipped with a quality  system which meets the Interna   tional Standards of Qual
61. ndirectly     Many of the same application  examples for the Pythagoras  functions are valid here too     DISTO computes the desired lengths  with three auxiliary measurements  using the Pythagoras function        PD Z32    i 3             The requirements for the auxiliary  measurements are the same as with  the Pythagoras function  but with the  following exceptions       The second auxiliary measured  point is also the end point of the  desired length      The third auxiliary measurement is  to be made at a right angle to the  desired length     After calling up the menu function the  following is displayed        height 4 5    Z    The first side if the triangle to be  measured and the corresponding  number  1  are displayed in black     c m E             Press briefly to change into  Pointing mode     Point at first measuring point with the  laser     Trigger measurement  Hold  DISTO steady     Without a stand there is the  E possibility of a shaky  measurement  Thus in the Pointing  mode either     use the time delay release  x key     or press the trigger key long enough  to start maximum tracking     Press briefly to confirm  displayed value        height 4 5    1 11454m  ME  3    11 454m             The first measured values appear  beside the corresponding  1     At the same time the second side of  the triangle to be measured or the  height of the triangle with the  corresponding number  2  is  displayed in black     Carry out the second auxiliary  measurement as d
62. nessesseesesstesseesessuseneesteneeeneeneens  Possible method of calculating the standard deviation s     ws  ACCURACY TOSIS pee                       Message Codes                 eeeeeeeennennenennnntententnntententnntenten trn tenten tnnt 61  Short c  t NdEX qe                       tanaa 62    English   6   DISTO    pro    pro  a 1 0 0en    Introduction    DISTO    pro  and DISTO    pro    a  the  top of the line of the new DISTO  series  offer the most in measuring  comfort     These instruments are perfectly  suited for quick width and distance  measurements  followed by  computations of partial distances   areas  volumes  etc     The three end covers supplied are  used to set the desired measurement  references  for corners  angles   edges  tripod  etc       Special features      Robust  proven reliability on  construction sites     Clear  lit displays     Alphanumeric keypad     Integrated pocket calculator  exten   sive functions for calculations     User friendly menus with short cuts     Memory allocation for up to 800  measured values     Language selection and selectable  measuring units     Integrated interface for data transfer  toa PC     DISTO    prof a  the utmost in  measuring accuracy of the DISTO  series    Area of applicability    This User Manual is valid for both  types  DISTO    pro  and  DISTO    pro    a     References made in this manual to  the product name DISTO  are valid  for both instrument types     Modes of operation  Normal mode    DISTO is
63. ng as soon as the  minimum distance has been  determined     Press briefly to confirm  displayed value        pythagoras 4 4  1 11 494m  2 8 529m    8 529m             The second measured value appears  beside the corresponding number   2   At the same time the last to be  measured side of the triangle with  the corresponding  3  is displayed in  black     If instead of taking the third  E measurement  the result key  is pressed  then the desired length is  computed from the two  measurements taken and displayed     Otherwise take the third  measurement     Press briefly to change into  Pointing mode     Point laser at third measured point     Press briefly to start  measurement or hold key    until minimum tracking starts     Press briefly to confirm the  displayed value     The third measured value is  displayed beside the corresponding  number  3      Each of the three measured  E values can be selected again  with the navigation key and  corrected by a new measurement     Press briefly to compute and  display desired length        pythagoras 4 4    1l 8 751m                pythagoras 4 4  1 11 494m  2 8 529m  8 593m  8 593m             Press briefly again to quit the  menu and to display the  result in basic settings      If desired  save result to a keypad  memory or to the data memory     English  o o 34     DISTO    pro    pro  a 1 0 0en    Basic functions  contd   Height  4 5     Using this menu function partial  heights not accessible for the  DISTO can be computed i
64. o before and  after important measuring jobs     Affix an adhesive label on the DISTO  for accuracy tests of measuring  equipment and keep a detailed  record of the test procedure     Your DISTO meets the specified  accuracy if standard deviation  remains smaller or equal to the  typical specified value     A DISTO whose measuring accuracy  has been tested over a test distance  works within the specified tolerance  over the entire distance and  temperature range specified in the  manual     Please note the technical data and  the description of measuring  accuracy in the manual    Message Codes    e p RN   em foana on   a fino    RSE econ Oe  Measurement time too long  distance  lt  250 mm Measurement time  gt  10 sec     peas Receiver signal too powerful Use target plate  correct side   E257 Wrong measurement  ambient brightness too high Use target plate  Not in data memory No data available    Erase memory location       Data memory full  All other messages    o Press briefly to acknowledge  messge and to return to basic  settings               Call service  system     When messages with this  symbol  appear even after  DISTO has been used  several times  then please  call the service station and  inform them of the message  number displayed        DISTO    pro    pro    a 1 0 0en       English    Short cut index    1 measure settings  1 1 reference    1 1 1  1 1 2  1 1 3  1 2 offset  1 2 1  1 2 2  1 2 3  1 3 timer  1 3 1  1 3 2  1 3 3  1 4 laser  1 4 1  1 4 2    front  sta
65. of        PD Z66                After calling up this menu function   the following is displayed        trapeze HSH 5 3    Cl             The first height to be measured   gutter height  and the corresponding  number  1  are marked in black     Press briefly to change into  Pointing mode     Point laser at the first point to be  measured     Trigger measurement  Hold  X  DISTO steady     If there is the possibility of a  E shaky measurement in the  Pointing mode either     use the time delay release  x key     or press the trigger key long enough  to start tracking     Press briefly to confirm  displayed value        trapeze HSH 5 3  1 3 739m    a  3  39m    The first measured value appears  beside the corresponding number  pe   At the same time the base side of the  trapezium to be measured is marked  in black with the corresponding  number  2                  Measure the base side of the  trapezium as described earlier and  confirm with the Enter key     Pressing and holding trigger key in  Pointing mode starts tracking     The second measured value appears  beside the corresponding number  vi       DISTO    pro    pro    a 1 0 0en       English    Calculation  contd     The next height to be measured  roof  beam height  is marked in black with  number  3          trapeze HSH 5 3  1 3 739m    a 2 2 665m             Measure roof beam height as  described earlier and confirm with  Enter key     Press and hold measurement key in  Pointing mode to start maximum  tracking     Ea
66. questions can be avoided     Enter text as described in menu    E function  6 4 1      Press briefly to move cursor    to next text line   l    Press briefly to end and store  input     After a confirmation basic settings  are displayed     As an alternative text input can be  made from a predefined list     Precondition  The list was loaded  into DISTO previously  read Online  documentation on supplied CD   ROM      Press briefly to display the  list of the predefined texts        6 4 2    store       fal 002    F abc                Select desired entry from list     Press briefly to confirm entry     Follow same procedure to input  subsequent entries from the list     Press briefly to end and store  text entries     After a short confirmation the basic  setting are displayed     In storing a new value  the  E DISTO automatically uses  the first two text lines of the last  memory location     Storing with Enter key  When a value displayed in the basic  setting is to be stored     Press and hold     The display shows    the next free memory location     a cursor to enter text     If desired  enter text as described  earlier     Press breifly to store     After a confirmation the basic  settings are displayed     If all results of a calculation are to be  stored  e g  pythagoras  triangles   heights       in the data memory     Press and hold immediatedly  after computed results are  displayed     The display shows    the next free memory location     a cursor to enter text   
67. r  2 2        adapter end cover 2 2    1 without add on    2 accessory 723775    3 accessory 723776  4 pivot gap  5 individual extension                The settings for how the adapter end  cover will be used are made here   These settings determine the rear  reference of the DISTO     Default setting  none  meaning that  after a reset all settings remain     Without add on  2 2 1    Select this menu function when the  adapter end cover is used without  any further add ons     After pressing the Enter key a short  confirmation appears and the menu  function is terminated     DISTO changes to Normal  mode and displays the   symbol of the adapter end  cover in the basic settings     Accessory 723775  2 2 2    This menu function sets rear  reference to the adapter end cover  with the optional short bracket  read  User Information  Accessories      After pressing the Enter key a short  confirmation appears and the menu  function is terminated     DISTO changes to Normal  mode and displays the basic   settings  The symbol of a   special adapter appears     Accessory 723776  2 2 3    This menu function sets rear  reference to the adapter end cover  with the optional long bracket  read  User Information  Accessories      After pressing the Enter key  a short  confirmation appears and the menu  function is terminated     DISTO changes to Normal  mode and displays basic  settings  The symbol of a  special adapter appears     Set pivot gap  2 2 4    Set pivot gap in this menu function 
68. rement  is triggered the laser turns off  automatically to save batteries   DISTO is then back in Normal mode     Press again to start laser and    to switch into Pointing mode        English       DISTO    pro    pro  a 1 0 0en    Switching off DISTO    To save batteries  the DISTO  automatically switches off after 90  seconds if no key is pressed in that  time  or it is not in Permanent mode     Manually  the DISTO can be  switched off in different ways      1  In Normal mode    e  e    Press both keys  simultaneously or hold one of  both keys and then press  second key     or select menu function   Switch off   3 6       Press briefly   o Enter short cut     2  In Pointing mode  in a menu  function  etc         Press one or more times until  the basic settings in Nomal  mode are displayed     Then press both keys  simultaneously or hold one of  both keys and then press  second key     e  e    Measuring   Switch on DISTO   Press briefly   DISTO is in Normal mode   Distance measurement    Press again briefly to activate  Pointing mode     Aim at object to be measured     Q Press again to trigger  DIST  n  distance measurement    The result is displayed in the  selected unit     Using menus    From the main menu  various  submenus can be called up from  which functions can be selected   refer to short cut index      Selecting menus   menu functions    Press briefly in Normal mode  to display the main menu        menu    1 measure settings    2 end cover  3 basic settings    4
69. rements  Pythago   ras  height  using any camera stand   DISTO rotates around a defined  geometrical point       As stand  we recommend the  SLIK U9000      wide swivelling range      no stand adapter required     Accessories for data interface    Data cable GEV102 1  725078   To connect to a PC or laptop   2 m  cable with Lemo plug  size 0 and 9  pole D plug with socket contact      DISTO    pro      pro  a 1 0 0en BETON English    Data cable  708175   To connect to a palmtop with a  standard cable  30 cm long cable  with cable with Lemo plug  size 0  and 9 pole D plug with pin contact    To connect PC s  laptops   E etc   a commercially available  zero modem cable is required     Transport accessories    Carrying pouch  667169    Large black carrying pouch for  transportation and protection   Compartments for user manual   telescopic viewfinder and palmtop  computer     Holster  667489   For max  protection  Fitted to belt     Wrist strap  667491    With fastening thread to prevent  instrument from dropping to the  ground while in use     Shoulder strap  563879   Adjustable with fastening thread     DISTO Clip  714871   To carry the instrument on your body  with special screw     The following directions should  enable the person responsible for the  DISTO  and the person who actually  uses the instrument  to anticipate  and avoid operational hazards    The person responsible for the  instrument must ensure that all users  understand these directions and  adhere to them    
70. ring turn swivel foot  on the end cover by 90          DISTO    pro    pro  a 1 0 0en       English    Using end covers  contd                    Or use the end cover with folded in  positioning bracket   alignment aid     Measuring from corners    Exact measurements from corners  can only be made with the end cover  with swivel foot    Just keep the swivel foot in its initial  position  aligned with the edge of the  end cover                        Measuring from edge    Normally the end cover with the  positioning bracket   alignment aid is  used                          PD Z34     v          As an auxiliary stop  the opened  closing cap of the interface plug can  be used        PD Z83             The stand as measuring reference  must be entered  when using the  auxiliary stop     Measuring with alignment aid  The DISTO is ideally suited for     marking off ops     e g  when staking  out distances           PD Z82                     Measuring with stand    Using a stand eliminates shaking  when measuring over a long  distance     The stand connection on the bottom  of the casing of the DISTO is  normally used     The thread of the stand  E should not be longer than 5 5  mm or it could damage the casing of  the DISTO           PD Z38                   English       DISTO    pro    pro  a 1 0 0en    Using end covers  contd   Measuring with accessories  The adapter end cover has two    threads for attachments  e g   customer specified end covers      To use the DISTO in high
71. s   they may cause harmful interference  to radio communications     However  there is no guarantee that  interference will not occur in a  particular installation     If this equipment does cause harmful  interference to radio or television  reception  which can be determined  by turning the equipment off and on   the user is encouraged to try to  correct the interference by one or  more of the following measures      Reorient or relocate the receiving  antenna      Increase the separation between  the equipment and receiver      Connect the equipment into an  outlet on a circuit different from that  to which the receiver is connected      Consult the dealer or an  experienced radio TV technician for  help     WARNING    Changes or modifications not  expressly approved by Leica  Geosystems for compliance could  void the user s authority to operate  the equipment     Product labelling     PD Z65             0         AVOID EXPOSURE  Laser radiation is emitted  from this aperture       OL                oz    This device complies with part 15 of   the FCC Rules  Operation is subject   tothe following two conditions    Uf This device may not cause harmful   tterference  and  2  this device must   Accept any interference received           w  including interference that may cause   undesired operation     A cA  This device complies with part  15 of the FCC Rules  Operation  is subject to the following two  conditions   1  This device may  not cause harmful interference   and  2 
72. s continuously  updated and displayed     Press again to end tracking   DISTO changes to Normal mode and  displays the maximum tracking value  in basic settings     Minimum tracking  4 2     Minimum distance measurement is  done by using minimum tracking        DISTO    pro    pro  a 1 0 0en       English    In tracking mode  the DISTO jen    Basic functions  contd     Application examples     measuring clear room ceilings      minimum distance measurement in  case of rough and wavy surfaces      rectangular or horizontal measuring  without stand                    After calling up this menu function    the laser lights up in Pointing mode     the following is displayed        Point DISTO at target  Move       DISTO slowly and generously  VE  over the target     Sm    In tracking mode the DISTO  E continuously takes single  measurements     The shortest distance is continuously  updated and displayed     DIST     DISTO changes to Normal mode and  displays the minimum tracking value  in basic settings     Press again briefly to end  tracking     Required distance  4 3           minimumtrac 4 2       required distance 4 3    2 variable                   Press briefly to start tracking     In this submenu fixed or variable  distances for staking out can be  selected     After a reset the entered distance  values remain unchanged     In staking out a distance is divided  into segments    The DISTO displays preset  distances  starting from a known   aimed at point    One by one th
73. s soon as measurement is done  briefly press trigger key again     DISTO    pro    pro  a 1 0 0en   37    O  English    3 242m    Calculation  5   Ax             The display shows     n  01 for the first measurement      the calculated average value below     all the way down the current value     Carry out all other measurements as  described earlier     Press briefly to display  average value in basic  settings     If desired save result to the keypad  or data memory     menu    1 measure settings  2 end cover  3 basic settings    4 basic functions    5 calculation    6 memory             calculation 5    1 triangle SSS    2 triangle SH  3 trapeze HHS    4 trapeze HSD  5 gable area  6 circle                Computation of circumference area  and room volume in this menu  function     Triangle SSS  5 1     After measuring the three sides   SSS  of a triangle  this menu  function computes     the height of the triangle       the angle opposite of the longest  side of the triangle     the area of the triangle     After calling up this menu function   the following is displayed        triangle SSS 5 1    MN    3             The first side to be measured and  the corresponding number  1  are  marked in black     Press briefly to change into  Pointing mode     Align DISTO and point with laser at  the first point to be measured     Trigger measurement  Hold  DISTO steady     Press and hold the trigger key and  start tracking for each side of the  triangle          Calculation  cont
74. short  confirmation appears and the menu  function is terminated    DISTO changes to Normal mode and  displays basic settings     The symbol in basic settings  is now the end cover with  swivel foot     Aligning aid  2 5     This menu function     sets rear reference for the DISTO to  the end cover with positioning  bracket   alignment aid      only appears when automatic end  cover recognition is turned off     After pressing the Enter key a short  confirmation appears and the menu  function is terminated    DISTO changes to Normal   mode and displays basic settings     The symbol in basic settings  is now the end cover with  positioning bracket    alignment aid     Basic settings  3   x       menu    1 measure settings  2 end cover  3 basic settings    4 basic functions  5 calculation  6 memory             basic settings    2 language  3 beep   4 reset   5 lighting   6 switch off                Units  3 1        units    0 000 m    2 0 00 m    3 0 00 feet  4 0 00  32          3 1          Sets the unit in which DISTO  displays measurement and  computation results  Additionally   when using the metric system the  amount of decimal digits can be set     Default setting  0 000 m  3 1 1     0 000 m  3 1 1    After selecting this menu function     the menu is quit and the basic  setting displayed      display is then in meters accurate to  three decimals     0 00 m  3 1 2    After selecting this menu function     the menu is quit and the basic  setting displayed      display is 
75. ter pressing the Enter key  a short  confirmation appears and the menu  function is terminated     The DISTO changes to Normal mode  and displays the basic settings     Data transfer  1 6   This submenu permits immediate    data tranfer from the DISTO via the  data interface to a PC or a laptop        send 1 6    1on  2 only results             Default settig  off  1 6 3     On  1 6 1    All measurements and calculations  are transferred  the data interface  transfers data continuously     Only results  1 6 2    Only measurement or calculation  results  e g  at maximum or minimum  tracking  are transferred     Off  1 6 3   The data interface is off       These menu functions are   described in the Online   documentation on the CD ROM  supplied     End covers  2      1x       menu    1 measure settings  2 end cover    3 basic settings    4 basic functions  5 calculation  6 memory          end cover 2    1 without end cover    2 adapter end cover  3 recognition                Without end cover  2 1     This menu function permits the use  of the DISTO without end cover     After pressing the Enter key a short  confirmation appears and the menu  function is terminated        English       DISTO    pro    pro  a 1 0 0en    End covers  contd     DISTO changes to Normal  mode and displays basic  settings  The symbol for the  instrument without end cover  appears     Avoid using DISTO without  Se end cover as the battery  cover is then exposed and may be  damaged     Adapter end cove
76. the hori   zontal  but in the vertical this can  lead to considerable height  deviations                       After calling up this menu function  the following is displayed        pythagoras 4 4    2  3                The first side of the triangle to be  measured and the corresponding  number  1  are displayed in black     Press briefly to change into  Pointing mode     Point at the first measuring point with  the laser     Trigger measurement  Hold  DISTO steady     Without a stand there is the  E possibility of a shaky  measurement  Thus in the Pointing  mode either     use the time delay release  x key     or press the trigger key long enough  to start maximum tracking        DISTO    pro    pro  a 1 0 0en       English    Basic functions  contd     Press trigger key as soon as the  distance has been measured in  maximum tracking mode     Press briefly to confirm  displayed value        pythagoras 44  1 11 494m    11 494m             The first measured values appear  beside the corresponding  1     At the same time the second side of  the triangle to be measured or the  height of the triangle with the  corresponding number  2  is  displayed in black     Align DISTO approximately at a right  angle with the reference  wall    Where the measured points were  arranged vertically  it would  correspond to the horizontal setting  of the DISTO     Press briefly to change into  Pointing mode     Press until minimum tracking  DIST   starts     Press briefly to end minimum  tracki
77. then in meters accurate to  two decimals     0 00 ft  3 1 3    After selecting this menu function     the menu is quit and the basic  setting displayed      display is then in feet as decimal     0  00  32  3 1 4    After selecting this menu function     the menu function is terminated and  the basic setting displayed      display is then in feet and inch     With inch values  decimals are  diplayed as fraction of 1 32     Example  8 5 inch   8 in 1      0 0 in  3 1 5    After selecting this menu function     the menu function is terminated and  the basic setting displayed      display is in inches with one decimal  accuracy     0  32  3 1 6    After selecting this menu function     the menu function is terminated and  the basic setting displayed      display is in inch     With inch values  decimals are  diplayed as fraction of 1 32     DISTO    pro      pro  a 1 0 0en BCEIIS English    Basic settings  contd     Language  3 2        language 3 2  English    1 Deutsch  2 English    3 Fran  ais             Set language the DISTO uses for  messages  settings  etc     ES seine cate handai  in this submenu    Default setting  none   Selectable languages    German  3 2 1    English  3 2 2     French  3 2 3     A fourth language can be  E loaded into the DISTO via the  interface  read Online documentation  on the CD ROM supplied      After pressing the Enter key a short  confirmation appears in the selected  language and the menu function is  terminated     DISTO changes to Normal 
78. truments        DISTO with Telescopic  Viewfinder    WARNING    Looking right at the reflected  laser beam in a DISTO operated with  telescopic viewfinder could be  dangerous when you aim at areas  that reflect like a mirror  or emit  reflections unexpectedly  e g  a  mirror  metallic surfaces  windows   prisms  liquids     Precautions    If you using a telescopic viewfinder   do not aim at areas that are reflective  like a mirror  or which could produce  unintended reflections  e g  mirrors   metallic surfaces  windows  prisms      Electromagnetic  Compatibility  EMC     The term  electromagnetic  compatibility  is taken to mean the  capability of the DISTO to function  smoothly in an environment where  electromagnetic radiation and  electrostatic discharges are present   and without causing electromagnetic  interference to other equipment     WARNING    Electromagnetic radiation can  cause interference in other  equipment    Although the DISTO meets the strict  regulations and standards which are  in force in this respect  Leica  Geosystems cannot completely  exclude the possibility that  interference may be caused to other  equipment     CAUTION    Interference can be caused in  other equipment if DISTO is used in  combination with third party devises   e g  field computer  PC  various  cables            English       DISTO    pro    pro  a 1 0 0en    Electromagnetic Compatibility  EMC   contd     Precautions    Only use equipment or accessories  recommended by Leica  They
79. unction calculates the  average value out of 10 sequential  distance measurements     Reasons for use      To achieve more exact results by  reducing the deviation      To compensate for shaky  measurements when DISTO is held  by hand     Using this menu function  E does not improve the  specified measuring accuracy of the  DISTO     This menu function cannot be  E set permanently     After calling up this menu function   the following is displayed        accuracy 4 6             The laser lights up in the Pointing  mode     Point at target with laser     Press briefly to trigger  measurement     DISTO performs 10 single  measurements and displays the  computed average value  The laser  switches off        accuracy 4 6    H n  10  x  8515m    Press briefly to quit menu  and display average value in  basic settings              If desired  save result to the keypad  or data memory     Average value  4 7     This menu function computes  E the average value of  measurements made by the user     It is possible to compute the average  values of up to 30 measurements     Application      Measurements made to uneven  walls and ceilings     English EET EI DISTO    prot   pro  a 1 0 0en    Basic functions  contd     Call up menu function           average 4 7       average 4 7    TIT not    x 3 242m             Press briefly to start laser in  Pointing mode     Point at target with laser     Trigger measurement  Hold  DISTO steady     Press and hold trigger key to start  tracking    A
80. ymbol  in basic mode has a referencing line    and an arrow    In Pointing mode the  E measurement reference can  be changed with the       navigation  keys  The next measurement is  made from the changed reference  and after that from the preset  reference        Front  1 1 1   Measurement from the front  of the instrument  Measuring  optics      Stand  1 1 2    Measurement from the stand  connected to the rear of the  instrument     This setting is also used when the  closing cap of the interface acts as  an auxiliary stop     Rear  1 1 3   Measurements from the rear  edge of the end cover     The DISTO automatically adjusts the  reference to the attached end cover   Read more in section  Using end  cover  and menu function  End cover  recognition on     2 3 1      After selecting and entering a  measurement reference  a short  confirmation appears and the menu  is terminated    The DISTO changes to Normal mode  and displays the basic settings    Add   Subtract  1 2        offset 1 2    1 addition  2 subtraction    3 none             This adds or subtracts to   from  measurements  Tolerances can be  taken into consideration  e g   between unfinishing and finishing  dimensions         15mm                         He                   PD Z78          Default setting  None 1 2 3     CAUTION    After every input of or change  in Add   Subtract  carry out a control  measurement     Save frequently used Add   Subtract  functions in the keypad memory and  call them up when needed 
81. ypad   recall it from the keypad memory or  from the stack    Brief press to confirm entry     ml press to quit menu  unction     DISTO changes to Normal   mode and displays basic settings   The symbol for individual extension  appears     e Distances entered are only  considered when reference is  set to rear     Recognition  2 3     Automatic end cover recognition is  Switched on and off in this submenu        recognition 2 3             Automatic recognition only  Eg works with end covers with  swivel foot or positioning bracket    alignment aid  Read section  Using  end covers      Default setting  on  2 3 1     On  2 3 1   Automatic recognition is on     After pressing the Enter key a short  confirmation appears and the menu  function is terminated     DISTO changes to Normal   mode and displays basic settings   The symbol of the detected end  cover appears     Off  2 3 2   Turns automatic recognition off     After pressing the Enter key  a short  confirmation appears and the menu  function is terminated     DISTO changes to Normal   mode and displays basic settings   The symbol of the most recently  detected or entered end cover  appears     te For each new end cover  the  respective menu function  must be entered     Rotating foot  2 4     This menu function     sets rear reference to the end cover  with swivel foot      only appears when automatic end  cover recognition is turned off     English   26   DISTO    pro    pro  a 1 0 0en    After pressing the Enter key  a 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
OneCommand Manager for VMware vCenter Release Notes    Western Digital Caviar Green 1TB 20PK  Samsung AW06EDB7 Manuel de l'utilisateur  HP Pavilion dv7-4280us  ICP - Conseil National de L`Emballage  Nortel Networks VSN04 User's Manual  MEP MHD6X  P201 UG web  E-Plex FIPS 201 Software User Guide    Copyright © All rights reserved. 
   Failed to retrieve file