        SA-1000K & SA-3000K Series Pure Sine Wave Inverter User`s Manual
         Contents
1.  SA 1000K    2        SA 3000K                  OUTPUT       3 1 2  ON   OFF  REMOTE  Main  switch    a  Before installing the inverter  you need to ensure the main switch  must be  OFF      b  Before using the remote unit  you need to ensure the main switch  must be    REMOTE        amlexpower    3 1 3  Input Level   Display Input Voltages                      LED Status DC 12V  RED Slow Blink 10 3 10 6 20 5 21 2  RED 10 6 11 0 21 2 21 8  ORANGE 11 0 12 1 21 8 24 1  GREEN 12 1 14 2 24 1 28 6  ORANGE Blink 14 2 15 0 28 6 30 0  OVER RED Blink 15 0t 30 01                   3 1 4  Load Level   Display AC Loads  Watts        LEDstatus DARK   GREEN ORANGE RED    SA 1000K 0   80W 80   330W 330   750W   750 960W   Over 960W       SA 3000K   0   240W 240   990W   990   2250W  2250   2880W   Over 2880W                            3 1 5  AC Frequency   Selected by    54    Dip Switch      Frequency   54    50 HZ OFF       60 HZ ON                amlexpower    3 1 6  Status   Display Power  amp  Fault Status                Green LED LED Signal Status  Solid Power OK  Slow Blink         Power Saving  Red LED LED Signal Status  Fast Blink              OVP  Slow Blink          UVP  Intermittent Blink SS SS SS OTP  Solid OLP                   3 1 7  Power Saving Mode  Power Saving Mode is adjustable and  set by the Dip Switches  S1  S2 and S3 on the front panel     Example  With the watt setting at 15W     15Wt load will make the  inverter operate normally  a 15W load will enter into the Pow
2.  instructions        1 1  General Safety Precautions    iaa     Do not expose the Inverter to rain  snow  spray  bilge or dust    To reduce risk of hazard  do not cover or obstruct the ventilation  openings  Do not install the Inverter in a zero clearance compartment   Overheating may result     1 1 2  To avoid a risk of fire and electronic shock  make sure that existing    1 1 3     wiring is in good electrical condition and not undersized   Do not operate the Inverter with damaged or substandard Wiring     There are some components in the inverter can cause arcs and sparks   To prevent from fire or explosion  do not put batteries  flammable  materials  or anything should be ignition   protected around the inverter     1 2  Precautions When Working with Batteries    1 2 1     1 2 2     1 2 3     122 4     If battery acid contacts skin or clothing  you shall wash it out with soap  and water immediately  If battery acid contacts your eyes  you shall  wash it out with cold running water for at least 20 minutes and get  medical attention immediately     Never smoke or make a spark or flame in the vicinity of the battery or  the engine     Do not drop a metal tool on the battery  The resulting spark or  short circuit on the battery of other electrical part may cause an  explosion     Remove personal metal items such as rings  bracelets  necklaces    and watches when operating with a lead acid batteries    Doing so may cause short circuit and very high temperature  which can  melt
3.  metal items and even burn you     5    samlexpower    2  Features    m Pure sine wave output  THD  lt  3    m Output frequency   50   60Hz switch selections    m Input  amp  output fully isolated design   m Power Saving Mode to conserve energy   m High efficiency 89 94    m Driving highly reactive  amp  capacitive loads at start moment  m Tri Color indicators show input voltage  amp  output load level  m Loading controlled cooling fan    m Advanced microprocessor  m Protection   Input low voltage Overload Short circuit    Low battery alarm Input over voltage Over temperature    2 1  Application    2 1 1  Power tools     circular saws  drills  grinders  sanders  buffers  weed  and hedge trimmers  air compressors  etc     2 1 2  Office equipment     computers  printers  monitors  facsimile machines   scanner  etc     2 1 3  Household appliances     vacuum cleaners  fans  fluorescent and  incandescent lights  shavers  sewing machines     2 1 4  Kitchen appliances     coffee makers  blenders  ice markers  toasters   etc     2 1 5  Industrial equipment     metal halide lamp  high     pressure sodium lamp   etc     2 1 6  Home entertainment electronics     television  VCRs  video games   stereos  musical instruments  satellite equipment  etc       samlexpower    A Division of Samlex America Inc     2 2  Electrical Performance                                  Item SA 1000K 112 SA 1000K 124  Continuous Output Power 1000W  Maximum Output Power 1100W  Surge Rating  Max  2000W  Input v
4. OFF switch on the Front panel to  turn the power       Then the power inverter is ready to deliver AC power to  your loads     there is several loads use  turn them on separately after the  inverter is    ON    in order to prevent OVP resulted from the surge power     3 7 1  Set the power switch to    ON    position and the buzzer will send out       Beep    sounds at the moment  Then the inverter will make self   diagnosis  and the LED s indicators will also appear various colors   Finally the buzzer will  Beep  again and the Input Level and Status  LED indicators will turn to  Green  color  then the inverter starts to  work successfully     3 7 2  Set the power switch to the OFF position  then the inverter stops and    all the lights go Off     3 7 3  Set the power inverter switch to ON position and turn the test load On     The inverter should supply power to the load  If you plan to  accurately measure the true output r m s  voltage of the inverter  a  meter such as FLUKE 45 BECKMAN 4410 or TRIPLETT 4200 must be  used     18    5    samlexpover    4  Troubleshooting       WARNING     Do not open or disassemble the Inverter   Attempting to service the unit yourself may cause the  risk of electrical shock or fire              Problems and Symptoms Possible Cause Solutions          No AC Power Output       STATUS illuminates the red LED    a  Blinking fast Over input voltage Check input voltage     OVP   Reduce input voltage   b  Blinking slowly Low input voltage Recharge ba
5. d black  terminal represents negative      Insert the cables into the terminals  and tighten the screw to clamp the wires securely     WARNING     Ensure all the DC connections are tight  torque  to 9     10 ft lbs  11 7     13 Nm   Loose connections  may cause overheat and fire              WARNING     The installation of a fuse must be on a positive cable   Failure to place a fuse on         cables running between  the inverter and battery may cause damage to the  inverter and will void warranty                 Also  use only high quality copper wire and keep cable length short  a  maximum of 3   6 feet     Battery to inverter cable connection                                                                                  i  1  i  i  1 ING TERMINAL    AWG 2    6             Do not place anything between  battery cable lug and terminal surface   Assemble exactly as shown        15    5    samlexpower       SA 1000K       Battery to inverter cable connection                                                                                                                                              Do not place anything between  battery cable lug and terminal surface   Assemble exactly as shown     16    5    samlexpover    3 6  AC Safety Grounding    The AC output ground wire should go to the grounding point for your loads   for example  a distribution panel ground bus       3 6 1  Neutral Grounding  GFCI   S      3 6 1 1  120V models  The neutral conductor of the AC output c
6. er                         saving mode    SA 1000K      3000   si Ese   sso   DISABLE   DISABLE OFF OFF OFF  20W 40W ON OFF OFF  40W 80W OFF ON OFF  55W 125W ON ON OFF  75W 170W OFF OFF ON  95W 210W ON OFF ON  115W 245W OFF ON ON  135W 280W ON ON ON                         samlexpower    3 1 8  AC outlets  available      Australia   New Zealand United Kingldom    2     0       5    samlexpover    3 2  Rear Panel Operations                   9       3 2 1  Remote Port   The SA Series Inverter is compatible with any of the remote controllers   S R8  S R6 12  S R6 24  Before using the remote unit  you need to ensure the main switch is in  the    REMOTE    position and the input voltage of the power inverter is  the same as it of the remote unit    3 2 2  Fan Ventilation     Be sure to keep it a distance  at least 1 inch  form surrounding things     3 2 3  DC Input Terminal      11    5    samlexpower    Connect DC input terminal to 12V   24V battery or the other power sources       represents positive  and       represents negative  Reverse polarity  connection will blow the internal fuse and may damage the inverter permanently     DC Input Voltage             Minimum Maximum  12V 10 5 15 0  24 V 21 0 30 0                3 2 4  Use wire   8 AWG to connect Chassis ground with vehicle chassis     WARNING     Operating the inverter without a proper ground  Connection may cause an electrical hazard           3 3  Protections Features       DC Input  VDC    Over Temperature Protectio
7. ircuit  of the Inverter is automatically connected to the safety  ground during inverter operation  This conforms to National  Electrical Code requirements that separately derived from AC  sources  such as inverters and generators  which have their  neutral conductors tied to ground in the same way as the  neutral conductors from the utility tied to ground at the AC  breaker panel  For models configured with a transfer relay   while AC utility power is present and the Inverter is in bypass  mode  this connection  the neutral of the Inverter   s AC output  to input safety ground  is not present so that the utility  neutral is only connected to ground at your breaker panel   as required     Ground Fault Circuit Interrupters  GFCI     Installations in Recreational Vehicles  for North American approvals  will  require GFCI protection of all branch circuit connected to the AC output of  the hardwire terminal equipped with Inverter  In addition  electrical codes  require GFCI protection of certain receptacles in residential installations   While the pure sine wave output of the Inverter is equivalent to the  waveform provided by utilities  compliance with UL standards requires us to  test and recommend specific GFCI    Samlex America Inc  has tested the following GFCI     protected 20A  receptacles and found that they functioned properly when connected to the  output of the Inverter     17    5    amlexpower    3 7  Inverter Operation    To operate the power inverter  use the ON   
8. l_Mar2010    
9. n    Model   Over Voltage Under   Under Voltage INTERIOR      down Alarm    12V 15 3V 14 3V 11 0V 10 2V 12 7V       24V 30 6V   28 8V 22 0V 20 3V   25 2V                         70  C 45  C 90  C 60  C    HEAT SINK       Shut  Voltage         Shut  Shut   Restart Restart Restart Restart  oe down down down       12    5    samlexpower    3 4  Installation    The power inverter should be installed in an environment that meets the  following requirements      3 4 1     3 4 2     3 4 3     3 4 4     3 4 5     3 4 6     Dry     Do not allow water to drip      or enter into the inverter     Cool     Ambient air temperature should be between 0  C and 40  C  the  cooler the better     Safe     Do not install the inverter in a battery compartment or other  areas where flammable fumes may exist  such as fuel storage areas or  engine compartments     Ventilated    Keep the inverter a distance  as least 1 inch  away from  surrounding things  Ensure the ventilation shafts on the rear and the  bottom of the unit are not obstructed     Dust     Do not install the Inverter in a dusty environments  The dust can be inhaled into the unit when the cooling fan is working     Close to batteries     Avoid excessive cable lengths  Do not install the  Inverter in the same compartment as batteries    Use the recommended wire lengths and sizes  see section 3 5     Do not mount the Inverter where it will be exposed to the gases  produced by the battery  These gases are very corrosive  and  prolonged exp
10. oltage 12V 24    Output              100  110 120       5                            50 60Hz     0 05    Switch Selectable                    Output Waveform Pure Sine Wave   THD  lt  3     Efficiency  full load  Max     89 0  92 0   No Load Current Draw  Max   1 43A 0 75A  Stand By Current Draw  Max   0 25A 0 15A     10 5 15 21 0 30  Input Voltage Regulation  VDC VDC          Input Level Indicator       Red   Orange   Green LED  Load Level Indicator                                        Failure Indicator Red LED              Overload  Short Circuit  Reverse Polarity  Fuse    Over   Under Input Voltage  Over Temperature   Remote Control Unit S R8  S R6 12  S R6 24 Optional  Safety Certification UL458  EMC FCC Class A  Operating Temperature Range 0  40  C  Storage Temperature Range  30  C to 70  C  Cooling Loading controlled cooling fan  Dimensions 383 L  182 W  88 H mm   15 08 L  7 17 W  3 46 H  Inch  Weight 4        8 8 Lbs           Note  The specifications are subject to change without notice     samlexpower                                  Item SA 3000K 112 SA 3000K 124  Continuous Output Power 3000W  Maximum Output Power 3300W  Surge Rating  Max  6000W  Input voltage 12V 24V  Output Voltage 100 110 120V     5   Frequency      50 60Hz     0 05    Switch Selectable                    Output Waveform Pure Sine Wave   THD    3926   Efficiency  full load  Max     88 0  91 0   No Load Current Draw  Max  3 0A 1 6A  Stand By Current Draw  Max  0 55A 0 35A    10 5 15 21 0 30  In
11. osure will damage the Inverter        WARNING     Shock Hazard  Before proceeding further  carefully  check that the Inverter is NOT connected to any  batteries  and that all wiring is disconnected from any  electrical sources  Do not connect the output terminals  of the Inverter to an incoming AC source        13    5    samlexpover    3 5  DC Wiring Connections    Follow this procedure to connect the battery cables to the DC input terminals  ofthe Inverter  The cables should be as short as possible  less than 10 feet    3 meters ideally  and large enough to handle the required current in  accordance with the electrical codes or regulations applicable to the  installation  Cables that are not an adequate gauge  too narrow  or too long  will deteriorate inverter performance such as poor surge capability and  frequent low input voltage warnings and shutdowns    These low input voltage warnings are due to DC voltage drop across the  cables from the inverter to the batteries  The longer and narrower the cables     the greater the voltage drop     Increasing DC cable size helps improve the situation  SAMLEX AMERICA    INC  recommends the following cables for optimum inverter performance                 SA 1000K 112  2 150A  SA 1000K 124  4 80     5   3000   112   4 0 400A                SA 3000K 124   2 0 200A          14    5    samlexpover    3 5 1  Connect the cables to the power input terminals on the rear panel of  the inverter  The red terminal is represents positive     an
12. put Voltage Regulation  VDC VDC          Input Level Indicator       Red   Orange   Green LED  Load Level Indicator                                        Failure Indicator Red LED  EEN Overload  Short Circuit  Reverse Polarity  Fuse    Over   Under Input Voltage  Over Temperature   Remote Control Unit S R8  S R6 12  S R6 24 Optional  Safety Cert  Meet UL458  EMC FCC Class A  Operating Temperature Range 0   40  C  Storage Temperature Range  30  C to 70  C  Cooling Loading controlled cooling fan  Dimensions 452 L  208 W  166 H mm   17 80 L  8 18 W  6 53 H  Inch  Weight 9 8kg   22 Lbs           Note  The specifications are subject to change without notice      1  This test condition is normal DC input  13 5V  and Temperature 25  C     samlexpower    2 3  Mechanical Drawings       Pure Sine Wave Power inverter    SA 1000K 340 00  13 39        SK700 71 50 2 83   SK1000 88 OO 3 46   SK1500 88 00 3 46     NE  DEn     182 00 7 17  191 00 7 52         5    samlexpover    SA 3000K 398  i  245 00  9 65   F         D        ADR                     165 25  6 51           209 00  8 23      amp     samlexpower    3  Introduction    This power inverter series is one of the most advanced line of mobile AC power  systems  To get the most effective power inverter  it must be installed and used  properly     Please read the instructions of this manual before you install and operate  this model     3 1  Front Panel Operations      3 1 1  Front view                  PURE SINE WAVE INVERTER am    
13. samlexpower    SA 1000K  amp  SA 3000K Series  Pure Sine Wave Inverter  User   s Manual    5    samlexpover  Table of Contents  1  Important Safety Information                                                         1 1 General Safety Precautions                                                     1 2 Battery Precautone A  UNE I  01 TE  2 1 AD DNC AN OM METTE  2 2 Electrical Performance                                                           2 3 Mechanical Drawings                                                             SEM m uuu               EES EE  9 1  Front Panel operation                                                            3 2 RaearPaneloperation                                                            deo Protections Features                                                              3 4  Installation Me               3 5 Making DC Wiring Connections                                                3 6      Safety Grounding                                                             3 7 Inverter Operation                                                                 4  Troubleshooting guide                                                                                                                                                                                                                                               6  Mee    5    samlexpower    1  Important Safety Instructions    WARNING     Before using the Inverter  read and save the safety 
14. ttery     UVP   Check connections    and the cable     c  Blinking Intermittently Thermal shutdown Improve ventilation    OTP   Make sure ventilation  shafts in the inverter  are not obstructed   Lower ambient    temperature   d  Solid ON Short circuit or Wiring Check AC wiring for  error short circuit   Overload  OLP  Reduce the load     19    5    samlexpover    5  Maintenance    To keep your inverter operating properly  there is very little maintenance required   You should clean the exterior periodically with a damp cloth to prevent  accumulation of dust and dirt  At the same time  tighten the screws on the DC  input terminals     6  Warranty    We guarantee this product against defects in materials and workmanship for a  period of 24 months from the date of purchase and will repair or replace any  defective power inverters if you directly returned them to us with postage paid   Please note that Samlex America Inc  is only responsible for ensuring our  products are operational before delivering  This warranty will be considered void if  the unit has been misused  altered  or accidentally damaged  Samlex America Inc   is not liable for anything that occurs as a result of the user s fault     20    5    samlexpower    Samlex America I          110 17 Fawcett Road  Coquitlam  BC  V3K 6V2 Canada    Toll free phone  1 800 561 5885  Toll free fax  1 888 814 5210    General Inquiries  samlex samlexamerica com  WWW  http   www samlexamerica com    034_2009_SA 1000K_SA 3000K_Manua
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
n°17 février 2008  SYBA SI-PEX40060    Pro Cam_Manual    Hans Grohe Axor Massaud Lavatory Mixer 18010001 User's Manual  Controlador Térmico Diferencial TDC 4  Peak Performer 1 RCP (910- Series) User Manual  NIBRS Coding Scenarios  DCP552 Digital Control Programmer Specification    Copyright © All rights reserved. 