1. 5 28 iet ER eet e ah oid ane ene 5 3 SMARTGATE STATUS INDICATION 6 3 1 INDIGATIONIFEDS tet 6 3 2 TELEPHONE LINE TONES 7 4 SIM CARD PIN PROTECTION 8 4 1 ENTERING BY PCMANAGER cccccceeececsecceceeceeueeeeueuceeuuueeueuseeuuueeuuueaeuueeeueueeuaueeeueueenaeeenauss 8 4 2 ENTERING VIA TELEPHONE LINE eeeeenn een ehem nnne nnnennnrnne nne nnn r ssa sn sanari n nia 8 4 3 AUTOMATIC PIN ENTERING i oto tt tte e ett eere tente ee eo teet dee ee er e ue e ee tats 9 D wOICEFUNGCHOGONB cce ada sin Guia vaa atta Buca snis ado cadem ais Gad cua d mata waa eaa ic a orta a Ewa Fade ste 10 5d BDIALTHBR GATEWAY eiiim ale ein Qe iiic i ere iiU ire pistes 10 5 2 GATEWAY FOR EXTENSION LINE OF PBX cccccceccceeecceeeceeeceeuuuceeeuceeueeveueueeeuaueeuueeeeueeeueeeeneneeenes 12 5 3 GATEWAY FOR TRUNK LINE OF 13 FAXFUNGHONS IK E DA FIERI Ded ru ROM rH DRY duet QR A RUNS OmU Eu FERE UOTE MODE 14 7 SMS SENDING INPUT heredis ax ws or bk e og bg dt lnc cbe i one d a 15 8 COM SERIAL INTERFACE eic a ac cce Ene
2. ri The voltage value mentioned on the power adapter may not be exceeded If you connect SmartGate to another power supply make sure that the voltage value is in the acceptable range a 1 When your SmartGate comes to the end of its operational life dispose of it in accordance with applicable regulations VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE User Manual Versions Version Amendments to Earlier Versions 1 00 e The User Manual applies to SmartGate FW Version 1 00A 1 01 e Analogue FAX support optionally Upgrade The manufacturer continuously meets customer requirements by improving the firmware For the latest SmartGate processor firmware programming tool and User Manual see www 2n cz For a detailed description of the SmartGate firmware upgrade refer to the section devoted to the PC programming tool VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Packing List SmartGate delivery contains the following items SmartGate Number of Pieces Antenna for direct connection Magnetic Antenna with coax cable Supply adapter Telephone cable PC connection serial cable SMS sending input connector Dowels Screws CD ROM with User Manual and software Quick Installation Guide mounting pattern Warranty certificate Notes 1 The delivery includes an antenna
3. SmartGate searches filled prefix as substring of the received CLI but max to position given by Substring parameter Positions are counted from zero See examples in Substring parameter hint Setting options 0 16 characters 0 9 Default setting blank Substring Parameter is used to make filling CLI prefix easier If parameter Substring gt 0 SmartGate searches filled prefix as substring of the received CLI but max to position given by Substring parameter Positions are counted from zero for example received CLI 4206031 98222 corresponds with settings CLI calling number Substring 420603198222 any setting 420603 any setting 420 any setting 603198222 4 or more 603 4 or more Setting options 0 15 Step 1 Default setting 0 34 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Route to It is possible to route incoming GSM call to FSX or FXO interface or reject it Remaining settings are planned to use for CallBack option in future Setting options FXS incoming call is routed to FXS FXO incoming call is routed to FXO reject incoming call is rejected Default setting FXS Dial in Parameter Dial in is used for automatic connection to switchboard operator or directly to other subscriber If this parameter is blank calling person has telephone line fully at disposal and has to dial the subscriber number by DTMF Setting options 0 16 char
4. 8 5 Combination of COM Traffic with Voice Calls As already mentioned SMS transmission can be made even during telephone calls The SMS program is only blocked temporarily during outgoing call to GSM establishing and incoming call from GSM ringing The same applies to PCManager monitoring A message announcing that SmartGate is blocked is displayed during voice call establishing No voice call to GSM can be made during CSD data transmission Outgoing and incoming calls even to GSM can be made during GPRS connection The GPRS connection remains active during the whole call to GSM but no data can be transmitted SmartGate is a GPRS terminal of class B Once the call is terminated data transmission is recovered immediately 17 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 8 6 List of Supported AT Commands There are original files related to SIEMENS GSM modules in the PDF format on the SmartGate CD ROM Caution Since the GSM module is primarily used by the SmartGate central processor for voice calls use AT commands carefully You might misconfigure the GSM module thus making SmartGate inoperative To solve most of these problems switch SmartGate off and on again to make the central processor execute full initialization of the GSM module Do not use particularly AT CMUT AT SNFI ATS3 AT CMUX ATASNFM ATS4 AT CSCS AT SNFO ATS5 AT SAIC AT SNFPT ATVO AT
5. Mobility Extension special SmartGate function e P A BX Private Automatic Branch Exchange Personal Computer based on the IBM PC standard Personal Identification Number SIM card securing password PUK Personal Unblocking Key a password used to unblock a blocked SIM card after repeated wrong PIN entering RS 232C a PC serial port standard SIM Subscriber Identity Module a chip equipped module to be inserted in a GSM device for identification SMS Short Message Service a term for the system and one unit message SW Software TTL Transistor Transistor Logic a standard digital technology defining voltage for levels 0 and 1 PSTN Public Switched Telephone Network 41 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 12 Technical Parameters GSM GSM module GSM bandwidth MC45 MC55 EGSM 900 GSM 1800 GSM 1900 MC46 MC56 EGSM 850 GSM 1800 GSM 1900 2W EGSM 850 900 MHz 1W GSM 1800 1900 MHz Receiver sensitivit 104 dBm Audio HR FR EFR Half rate Full rate Enhanced full rate Echo cancellation Echo suppression GPRS Class 10 4 2 max 85 6 kbps downlink CSD max 14 4 kbps Coding scheme CS 1 2 3 4 Fax Fax Group 3 on model with fax converter 850 900 1800 1900 MHz 50 Transmission power DATA amenna SMA antenna connector SIM card 3V or 1 8V plug in Power Supply Mains supply 230
6. Place phone lines and connected terminals and PBX s faraway from antenna e For the allowed range of operating temperatures refer to the Technical Parameters tis impossible to operate SmartGate on sites exposed to direct solar radiation or near heat sources e SmartGate is designed for indoor use It may not be exposed to rain flowing water condensed moisture fog etc e SmartGate may not be exposed to aggressive gas acid vapours solvents etc e SmartGate is not designed for environments with high vibrations such as means of transport machine rooms etc 2 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 2 2 External Antenna Connection Screw the antenna enclosed into the SMA antenna connector Tighten the antenna connector gently with your hand never use spanner The antenna for direct connection has a sufficient gain for trouble free operation in normal conditions If the GSM signal is poor in case of voice disturbance or if you want to place your antenna separately from SmartGate you can use an antenna with an SMA connector terminated coax cable The antenna should be mounted vertically For antenna and cable parameters see the Technical Parameters 2 3 SIM Card Installation Open the SIM card holder on SmartGate s backside insert the SIM card and close it properly Select the required GSM provider and SIM card services such as call forwarding
7. SmartGate generate continuous dial tone Morse A SmartGate generate dial tone with 330 330 660 660 ms cadence Default setting Continuous Busy tone frequency Hz Setting of frequency frequencies of busy tone Setting options 1 3400 Hz Setting step 1Hz Default setting 425 Hz Busy tone cadence Busy tone cadence setting Setting options 330 330 ms cadence 330 ms tone 330 ms pause 200 200 ms cadence 200 ms tone 200 ms pause 250 250 ms cadence 250 ms tone 250 ms pause 375 375 ms cadence 375 ms tone 375 ms pause 500 500 ms cadence 500 ms tone 500 ms pause Default setting 330 330 ms Tone after disconnection If the remote subscriber hangs up first the SmartGate subscriber can hear the tone selected here Setting options Busy SmartGate transmits the busy tone upon call end Permanent SmartGate transmits the permanent tone upon call end Default setting Busy tone Line reversal indication for call in progress Select call in progress signaling by telephone line polarity reversal on FXS interface There is voltage of reversed polarity on the telephone line during the whole call Setting options YES NO Default setting NO 23 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Tariff pulse when call starts ends Signaling of call start or end by tariff pulse Setting options None SmartGate doesn t send tariff pulse as signaling of call start end C
8. 12V 0 5A adapter DC power supply 10 to 16 V DC accumulator 12V Standby 100 mA 12V consumption Call data typ 300 mA max 400 mA Supply connector DC Jack 5 5 2 1 mm Telephone Interface FXS for PBX external line or phone set Interface type 2 wire analog FXS Telephone connector type RJ 11 6 2 Line impedance 600 Q Loop voltage 26 V DC Loop current max 40 mA Loop resistance max 800 Q Tone frequenc adjustable default 425 Hz Dialing type tone DTMF or pulse Ringing voltage 42 Vrms 50 25 Hz Calling line identification CLI during ringing according to ETSI FSK Tariff pulses f 16 12 kHz Umin 100 mVef on 200 Q Answer supervision polarity reversal 12 16 kHz pulses Telephone Interface FXO for PBX extension line Interface type 2 wire analog FXO Telephone connector type RJ 11 6 2 Line impedance 600 Q On hook DC resistance 1 Off hook line voltage typ 4 5 V 25 mA Dial tone frequency adjustable default 425 Hz Ringing voltage Min 20 Vrms 25 50 Hz Ringing impedance 4 10kQ 50 Hz Dial thru parameters Voltage drop typ 1 7V 25 mA Closed loop resistance typ 160 42 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE e SMS Sending Input Closed loop resistance Open loop resistance Input overvoltage protection Data Interface RS 232C Connector Interface transmission rate 1200 115200 bps autobaudin Others Dimensions w o connect
9. Beep after dialing end If SmartGate is programmed as FXO gateway parameter enables a beep to signal the end of dialing beginning of outgoing call establishing Setting options YES NO Default setting YES Dial tone frequency Hz Setting of frequency frequencies of dial tone Setting options 1 3400 Hz Setting step 1Hz Default setting 425 Hz Dial tone cadence This tone is generated after Off Hook in case SmartGate is ready to accept dialing Setting options Continuous SmartGate generate continuous dial tone Morse A SmartGate generate dial tone with 330 330 660 660 ms cadence Default setting Continuous 26 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Busy tone detection Set number of busy tone periods for detection of call disconnection from your PBX The 0 setting disables busy tone detection Setting options 0 255 Step 1 Default setting 4 Continuous tone detection ms Set duration of constant frequency continuous tone for detection of call disconnection from your PBX The 0 setting disables continuous tone detection Setting options 0 8900 ms Step 35 ms Default setting 2030 ms BabyCall number If SmartGate is programmed as FXO gateway parameter defines a number to be dialed for the automatic call function If this item is blank the function is disabled Setting options 0 20 characters 0 9 Default setting blank BabyCall timeou
10. call barring preferred networks SMS service centre etc in your mobile phone before inserting your SIM card in SmartGate 3 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE e 2 4 Connector description SMS sending input Telephone line interface FXO RJ 11 6 2 2 DC Jack 5 5 2 1mm Power supply connector 0000 RS232C serial line D Sub 9 pins 2 5 Telephone Lines Connection 2 5 1 DialThru gateway basic connection Phone set is normally connected to extension line of PBX Wire up SmartGate between phone set and PBX Link extension line of PBX to FXO interface and phone set to FXS interface on SmartGate Optionally you can connect analogue fax special model of SmartGate 2 5 2 Gateway for extension line of PBX Link free extension line of your PBX to FXO interface on SmartGate FXS interface remains unconnected 2 5 3 Gateway for trunk line of PBX Link free trunk line of your PBX to FXS interface on SmartGate Program PBX to route all GSM calls to SmartGate Incoming calls from GSM network will be routed to PBX You can connect a standard telephone answering machine or any other FXO interface terminal to SmartGate Outgoing calls from phone will be routed to GSM network incoming calls from GSM will ring on the phone Optionally you can connect analogue fax special model of SmartGate SmartGate is equipped with the FSK based CLIP a
11. e Flashes once in 3s data connection in progress 3 Telephone line On FAX models e Flashes 2 times then pause fax connection in progress after power on signalize need of FW upgrade e Flashes 3 times then pause fax connection in progress Green for FXO interface e Flashes quickly line off hook or ringing Light call FXO GSM Alternately orange and green e Quickly ringing from FXO is connected to FXS interface e Slowly call FXS FXO 6 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE e 3 2 Telephone Line Tones 3 2 1 Status Tones The GSM gateway sends tones to the telephone line to indicate the line status The tone frequency is 425 Hz in initial setting Frequency is programmable it is possible to set up double frequency tones Dial tone Continuous tone or morse A according to setting e SmartGate is ready to receive dialing Ringing tone The called subscriber s telephone is ringing e The GSM network or connected PBX transmits this tone Busy tone programmable cadency e n case of call routing to GSM network SmartGate generate busy tone in any of the following cases SIM card has not been installed SmartGate is not registered to GSM network SmartGate is registered into a foreign network but roaming is disabled The called subscriber line is busy The called subscriber hangs up disconne
12. to be connected directly to the SmartGate SMA connector An antenna with a cable should be used when GSM signal is poor or in case of interference with other devices 2 Enclosed software SmartGate PCManager for parameters programming SmartGate SMSgateway for easy SMS sending and receiving SmartGate Driver for PC User Manual in paf format Lists of AT Commands for SIEMENS GSM modules VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE CONTENTS T SMARTGATE PUR O S E ueri redire iP T EFE V dd vai xe i ran xu Yen eus uvas TRE QVE EE EF EP VY Te vao Erud n 1 1 1 BASIC EUNGTIONS 1 ende ibt use emi bt E eel sad ee LET E ee Ea 1 1 2 ADVANTAGES OF SMARTGATE 1 2 INSTALLATION orien ori eoe d ei cea Ev xcu xi gin inen c oec er C o ec n vw Ed 2 241 PROPER LOCATION cove des bones Maes 2 2 2 EXTERNAL ANTENNA CONNECTION ccccccceeccceececueeeeeeceeuuceeeeeeeuuceeueueeueueeeuuueeueueesauueeueueeeaueeeneuss 3 23 SIM CARD INSTALLATION e cede ect dee ee E in choad E E e 3 2 4 CONNECTOR DESCRIPTION cccccccseeccccsececsscscceesccecnecueeseceecenecescsaueeceeceusecseseuseeeeeteaeesseurensasansess 4 2 5 TELEPHONE LINES 4 2 6 POWER SUPPLY CONNECTION 5 2 7 SMS SENDING INPUT CONNECTION
13. 2N SMARTGATE GSM GATEWAY Wireless Modules by Siemens Dramatic cost saving DialThru technology gateway with ME function Voice Data and SMS transmission Analogue FAX optionally FXS and FXO interfaces for PBX or phone sets FSK CLIP VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Dear customer Let us congratulate you on having purchased the SmartGate system This new product has been developed and manufactured to provide the maximum utility value quality and reliability We hope you will be fully satisfied with this GSM gateway for a long time Therefore use your SmartGate for purposes it has been designed and manufactured for in accordance herewith The manufacturer reserves the right to modify the product in order to improve its qualities Safety Precautions Do not switch on SmartGate in the vicinity of medical apparatuses to avoid interference The minimum distance of the antenna and pacemakers should be 0 5 m S Do not switch on SmartGate aboard of a plane Do not switch on SmartGate near petrol stations chemical facilities or sites where explosives are used Any mobile telephone use prohibition based on RF energy radiation applies to SmartGate too PX SmartGate may disturb the function of TV sets radio sets and PCs Warning SmartGate contains components that can be swallowed by small children SIM card antenna etc
14. ATE Add The Add parameter is used for automatic call routing A defined string prefix is added to the beginning of the number to be dialed Setting options 0 16 characters 0 9 Default setting blank 33 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE GSM routing table Incoming calls from GSM contain the CLI According to received CLI SmartGate can do following e Reject the call e Route the call to FXS or FXO interface e Automatic dial in SmartGate dials preprogrammed PBX subscriber number for example switchboard operator to be connected with calling GSM subscriber FXS line Off Hook to DISA timeout ms Timeout between FXS line Off Hook and automatic dial in according to parameter Dial in in the table Setting options 100 25500 ms Setting step 100 ms Default setting 2000 ms FXO line Off Hook to dial in timeout ms Timeout between FXS line Off Hook and automatic dial in according to parameter Dial in in the table Setting options 100 25500 ms Setting step 100 ms Default setting 1000 ms CLI calling number Fill in CLI to route the call according to parameter on the same table line It is possible to fill in only prefix for group of CLI s If parameter Substring 0 you must fill prefix as you see it on display of your mobile phone It means inclusive of and international prefix if they are included If parameter Substring gt 0
15. CLI is compared with filled rows of GSM routing table The call is rejected routed to FXS interface connected phone or to FXO interface according to the routing table Routing to FXO interface isn t usually used in case of DialThru gateway 2 Ringing on FXS interface signals incoming call The Line LED flashes during ringing If programmed so SmartGate transmits the CLIP by FSK between the first and second rings Advanced telephone sets are able to display the CLI 3 Hook off the phone to establish the call The Line LED is permanently on during the call 4 Hang up to terminate the call The Line LED goes off If the called subscriber hangs up first you can hear the busy tone 10 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 5 1 3 Incoming call on FXO interface 1 SmartGate detects a ringing signal and immediately interconnects it to FXS interface the phone starts to ring 2 The CLIP transmitting must provide connected PBX 3 If you hook off the phone the call is established 5 1 4 Automatic Call BabyCall If the BabyCall function is enabled on FXS interface a pre programmed timeout is counted down after off hook If you don t start dialing within this timeout SmartGate signals dialing end and starts to establish a call to the pre programmed number using GSM network automatically from now SmartGate behaves as if a standard outgoing call to GSM had been
16. Eo eoe ako a C aco 16 8 1 PROGRAMMING 16 8 2 CSD PC PC DATA TRANSMISSION 16 8 3 CSD OR HIGH SPEED GPRS DATA CONNECTION TO INTERNET eeeeen eene rne 17 8 4 SMS SENDING AND 17 8 5 COMBINATION OF COM TRAFFIC WITH VOICE 9 17 8 6 LIST OF SUPPORTED AT COMMANDS cccccccececeecceeecceeuuceseuueeceueeeuuueeueueeeeaueeueeeeaaeeeaeeeeneneeeaes 18 9 SMARTGATE PARAMETER PROGRAMMING 19 9 1 PC BASED PROGRAMMING cccccccccccscceceseeccseeucecuueeeeeuceeeuueeueeeueueeeuuueeueueeeuaueenesesaueeeuaueeneneeeags 19 92 EAEE TOE 22 10 THOUBEESHOOTINQG a see Troad 40 11 LIST OF ABBREVIATIONS 2 CV a Ya acad aaa a ku aan idc 41 12 TECHNICAL PARAMETERS cccccecccseccceecceeeeeeeceseeeeeeneeeeueeeeeeneeeeesseneeenaeeeueeeeeseneeenees 42 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 1 SmartGate purpose 1 1 Basic Functions e The primary purpose of SmartGate is to transmit voice between GSM n
17. LI is replaced by the defined string The character can neither be transmitted by the FSK protocol nor dialed by the DTMF from a terminal Setting options 0 4 characters 0 9 Default setting blank 24 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE BabyCall number A number to be dialed for the automatic call function If this item is blank the function is disabled Setting options 0 20 characters 0 9 Default setting blank BabyCall timeout s Time between line Off Hook and automatic call beginning if enabled During this timeout SmartGate waits for dialing that cancels the automatic call You can make standard call if the BabyCall function is enabled Setting options 0 255 s Setting step 1s Default setting Os Transmission volume Volume setting for GSM transmission with a 4 dB step Setting is common for both FXS and FXO interfaces Default setting medium volume level Reception volume Volume setting for GSM reception with a 4 dB step Setting is common for both FXS and FXO interfaces Default setting medium volume level 9 2 2 Telephone interface FXO parameters Number of rings before Off Hook If SmartGate is programmed as FXO gateway parameter sets the count of rings before Off Hook Setting options 1 255 Step 1 Default setting 1 Time for dialing start If SmartGate is programmed as FXO gateway parameter defines timeout for first dialing
18. M provider s messages 6 When the called subscriber answers the call a call is established The orange Line LED is permanently on during the call 7 Hang up to terminate the call The Line LED goes off If the called subscriber hangs up first you can hear the busy tone 5 3 2 Incoming call from GSM network 1 The CLI is compared with filled rows of GSM routing table The call is rejected or routed to FXS interface connected phone according to the routing table 2 Ringing on FXS interface signals incoming call The orange Line LED flashes during ringing If programmed so SmartGate transmits the CLIP by FSK between the first and second rings Advanced telephone sets are able to display the CLI 3 Hook off the phone to establish the call The Line LED is permanently on during the call 4 Hang up to terminate the call The Line LED goes off If the called subscriber hangs up first you can hear the busy tone 13 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 6 FAX function Sending fax message to and from PSTN FAX call to PSTN routed from FXS to FXO interface DialThru gateway works on every model and needn t any other settings GSM fax message SmartGate with fax converter has ability to send and receive GSM fax messages using analogue fax Group 3 connected to telephone line FXS The fax communication service must be registered with your GSM operator Sending a
19. SM20 AT SNFS AT amp CO AT SMSO AT SNFV AT IPR AT SNFA AT SNFW z AT CFUN AT SNFD 18 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE e 9 SmartGate Parameter Programming Most of SmartGate s parameters have such default values that meet most users demands and need not be changed Usually you have to program routing tables according to SmartGate usage Use a PC with the PCManager installed for SmartGate s parameter programming 9 1 PC based Programming For programming connect SmartGate to a PC with a serial cable and make sure that the SmartGate PCManager is installed Programming is intuitive and easy All items and parameters are accompanied with texts hints just point at anything with the mouse cursor SmartGate data uploading and storing including firmware upgrade are executed in a special mode in which SmartGate waits for about 3s after power up all LEDs are on If instructed so by the PCManager during this timeout SmartGate remains in this mode as long as it is necessary If SmartGate is not reset after the PCManager is terminated switch the system off and on again Data handling Upgrade ian MATS Language MR From SmG Bard Save to SmG Load from disk 49 Save to disk Monitoring 19 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 9 1 1 Basic Programming Instructions 1 Run
20. ach provider especially the telephone number to be dialed DNS etc It is necessary for example to set the APN in modem extra settings in the GPRS mode Example at cgdcont 1 IP internet t mobile cz Caution GSM providers mostly specify the 99 number to be dialed for GPRS connection in their instructions SIEMENS GSM modules require the 99 1 format 8 3 1 CSD or GPRS Data Connection The maximum CSD transmission rate is 14400 bps GSM connection is reserved for the whole time of connection and calls are charged according to the connection time The CSD mode can provide data connection of two PCs SmartGate is equipped with GSM modules providing GPRS class 10 4 2 timeslots which means that it is able to transmit data into a PC at the rate of 85600 bps and at half the rate towards the GSM network The GPRS cannot be used for connection of two PCs It can only provide connection with an APN e g the Internet Most GSM providers charge GPRS connections according to the volume of data transmitted or by a lump sum and so the GPRS is suitable for long time connection with occasional data transmissions 8 4 SMS Sending and Receiving It is possible to send and receive SMS units using appropriate AT commands There are a number of PC programs that are based on this principle Install SW designed for SIEMENS GSM modules SIEMENS mobile telephone SW can also be used You can send and receive SMS even during SmartGate voice calls
21. acters 0 9 Default setting blank 35 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 9 2 4 SMS Sending Input Parameters Telephone number for SMS The telephone number to which an SMS is sent upon SMS input activation If blank the function is off Setting options 0 16 characters 0 9 Default setting blank SMS text The SMS text to be sent to the preset telephone number If the SMS text is blank an empty SMS is sent Setting options 0 40 characters Default setting blank Send if activated longer than ms Set the SMS activation time necessary for SMS sending This parameter prevents SMS sending in the event of short time activation If a 0 is selected SMS is sent immediately upon the input activation Setting options 0 25500 ms Setting step 100 ms Default setting Oms Timeout after sending s Set the Time of inactivity after SMS sending During this timeout no SMS is sent even if the SMS input gets activated This prevents sending multiple SMS units in the case of repeated activation of the input Setting options 0 2550 s Setting step 10s Default setting Os 36 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 9 2 5 GSM amp SIM Parameters GSM operator lock Provider blocking is set by manufacturer in SmartGate If SmartGate is blocked to a GSM provider no other GSM providers SIM c
22. ades to extend functions To load new firmware into SmartGate use the Upgrade function Keep communicating with the manufacturer Serial number SmartGate serial number for information only cannot be changed Must be used for communication with the manufacturer GSM operator lock Refer to GSM amp SIM Parameters 38 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE COM enable With this parameter you can enable disable the serial interface function You can disable communication in the operating mode maintaining the special programming mode after power up Setting options YES NO Default setting YES Time period for GGMC SMS h Time interval for GGMC SMS sending GGMC GSM Gateway Monitoring Centre The 0 setting means that the function is disabled Setting options 0 255 h Step 1h Default setting 0 Telephone number for service SMS Telephone number for service SMS The number is common for GGMC SMS and LOW CREDIT SMS on prepaid SIM cards Setting options 0 16 characters 0 9 Default setting blank 9 2 7 Initialization All programmable parameters are arranged in tables according to their functions You can initialize either all parameters at once or one table of parameters 9 2 8 Security Parameters PIN value Fill in the PIN value for automatic PIN entering upon SmartGate power up It is applied only if the SIM card is PIN secured If the gi
23. all duration Setting options 0 255 s Setting step 1s Default setting Os 30 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE FXO routing table Calls from FXO interface are routed according to FXO calls rote to parameter You can set SmartGate as DialThru gateway or as gateway for extension line of PBX You can program ME function for the DialThru gateway For gateway for extension line of PBX you can fill in the FXO routing table According to the prefix of dialed number on FXO interface you can e Bar the number to be dialed SmartGate hangs up the call isn t established e Accelerate connection establishing by knowing the number length for the given prefix e Accelerate connection establishing by allowing to terminate dialing with a e Modify the number to be dialed by removing and or adding prefix The principle of table function is the same as in the FXS routing table The call is controlled according to parameters on the row with dialed number prefix match Remember to fill in the Other prefixes line for a number whose prefix is not found in the table FXO calls route to The main parameter for FXO calls routing You can program SmartGate as DialThru gateway or as gateway for extension line of PBX DialThru gateway Incoming ringing is immediately connected to FXS interface If function ME set SmartGate starts to establish GSM call to ME number after defined
24. all end SmartGate sends tariff pulse when call ends Call start SmartGate sends tariff pulse when call starts Call start and SmartGate sends tariff pulse when call starts and ends too Default setting None Tariff pulse frequency kHz Tariff pulse frequency setting Setting options 16 kHz SmartGate transmits 16 kHz tariff pulses 12 kHz SmartGate transmits 12 kHz tariff pulses Default setting 16 kHz Ringing signal frequency Hz Ringing signal frequency setting Setting options 25 50 Hz SmartGate rings with 50 or 25 Hz on FXS interface Default setting 50 Hz Ringing signal cadence Ringing signal cadency setting Setting options 1000 4000 ms 1 s ring 4 s pause 400 200 400 2000 ms 400ms ring 200ms pause 400ms ring 2s pause 1500 3500 ms 1 5 s ring 3 5 s pause 2000 4000 ms 2 s ring 4 s pause Default setting 1000 4000 ms CLI transmitting Set this item to enable disable identification of a telephone line calling from a GSM network The function can be enabled if you have a device on your telephone line that is capable of receiving FSK according to ETSI standards Setting options Disable SmartGate does not transmit the CLI FSK during ringing SmartGate transmits the FSK based CLI according to the ETSI EN 300 659 standard transmission during ringing Default setting Disable Replace character in CLI by If this parameter is filled the character in the international prefix of C
25. an lower your credit Setting options 0 8 characters 0 9 Default setting blank 37 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Minimal credit Set minimal credit value to send warning SMS LOW CREDIT If credit is lower then given value warning SMS is send after every credit check until you recharge your SIM card Setting options 0 999 Step 1 Default setting 0 Credit value position in received SMS If there are more numbers except credit value in text answer e g date time and so on SmartGate seeks the number corresponding with credit value from given position in text The seek algorithm skips every non number character If credit value is the first number in text you can leave setting O If there are other numbers before credit value set parameter to text position from which the algorithm will seek Setting options 0 180 Step 1 Default setting 0 Telephone number for service SMS Telephone number for service SMS The number is common for GGMC SMS and LOW CREDIT SMS on prepaid SIM cards Setting options 0 16 characters 0 9 Default setting blank 9 2 6 Service Parameters Hardware version SmartGate hardware version for information only cannot be modified Must be used for communication with the manufacturer Firmware version SmartGate firmware version SmartGate central processor program version The manufacturer can issue upgr
26. anently on and you can hear the dial tone upon line off hook 5 1 DialThru gateway Extension line of PBX is connected to FXO interface and phone is connected to FXS interface on SmartGate 5 1 1 Outgoing call on FXS interface 1 Hook off the telephone you can hear the dial tone and the Line LED starts flashing 2 Dial the required subscriber number SmartGate receives tone dialing DTMF by default If your telephone transmits pulse dialing only program SmartGate to receive pulse dialing The delay between dialed digits may not exceed 5s programmable parameter The number is evaluated as complete after this timeout 3 A short delay follows the last dialed digit for SmartGate to await further dialing Then the dialing end is signaled and connection is established 4 Prefix of dialed number is compared with filled rows of FXS routing table The call is rejected routed to GSM network or to FXO interface according to the routing table 5 the called subscriber is available you can hear the ringing tone If not you can hear the busy tone or any of the GSM provider s messages 6 When the called subscriber answers the call a call is established The Line LED is permanently on during the call Orange for calls to GSM Green Orange alternate for FXS FXO calls 7 Hang up to terminate the call The Line LED goes off If the called subscriber hangs up first you can hear the busy tone 5 1 2 Incoming call from GSM network 1 The
27. ard can be used If an unacceptable SIM card is used the GSM module does not register to GSM and the GSM network LED flashes quickly on the SmartGate panel CLIR incognito Sets the calling line identification restriction CLIR for outgoing calls from SmartGate Attention before enabling it is necessary to activate this feature by GSM operator otherwise outgoing calls can be rejected by GSM network Setting options According to provider depending on how the function is selected in the GSM network Activation ID is not sent Suppression ID is always sent Default setting According to provider Roaming enable disable You can make SmartGate work even if it is registered to a foreign GSM network Setting options Disable The GSM module logs out of a foreign network and attempts to register again in within 5 minutes Enable SmartGate works in any GSM network Default setting Disable Time period for low credit checking h Set to change time interval between credit checks If your credit drops under defined value SmartGate sends SMS LOW CREDIT The 0 setting means that the function is disabled Setting options 0 255 h Step 1h Default setting 0 Code for credit checking Credit in prepaid SIM cards is checked by network function which displays text message on mobile phone display Code of network function must be terminated with symbol ATTENTION find out if you have to pay for this function Every check c
28. ction The called number has too many digits more than 30 The called number is barred e n case of call routing to SmartGate s FXO interface SmartGate generate busy tone in any of the following cases Line is not connected There is no current on the line The called number has too many digits more than 30 The called number is barred If the called subscriber line is busy or called subscriber hangs up busy tone is generated by PBX Dialing end signaling e Dialing reception has been terminated Connection is being established PIN tone e Enter the PIN code e This tone is transmitted upon power up if the PIN has to be entered manually PUK Tone nnn e Enter the PUK code e This tone is transmitted upon repeated wrong PIN entering attempts SIM card is blocked 7 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 4 SIM Card PIN protection If a SIM card is PIN protected and the PIN is not programmed in SmartGate GSM LED indicates the state and the PIN tone is transmitted on telephone line 4 1 PIN Entering by PCManager Like other parameters the PIN code can be entered using a PC programming tool The PIN will be entered automatically upon every SmartGate power up 4 2 PIN Entering via Telephone Line PIN entering via a telephone line connected to FXS interface 1 Hook off the phone you can hear the PIN tone 2 Enter the PIN using
29. digit After timeout SmartGate hangs up the line Setting options 1 255 s Step 1s Default setting 15s Timeout for dialing end recognize s If SmartGate is programmed as FXO gateway parameter defines timeout during which SmartGate waits for further digits to be dialed It starts to establish connection when this timeout passes Setting options 1 255 s Setting step 1s Default setting 5s 25 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Type of transmitted dialing Set type of dialing for automatic dial in from GSM and for dialing during outgoing call from FXS interface Setting options DTMF SmartGate transmits tone dialing for future use Default setting Minimal On Hook ms Parameter defines minimal time of line On Hook between calls Set the parameter longer then duration of FLASH on your PBX Setting options 100 25500 ms Step 100 ms Default setting 1500 ms Maximal Off Hook without dialing s Parameter defines maximal time of line Off Hook before dialing to FXO interface during outgoing call from FXS interface Set up shorter time then timeout from extension line Off Hook and dialing receiver disconnection on your PBX In this case PBX usually changes dial tone to busy tone If defined timeout passes before dialing SmartGate shortly hangs up after that Off hooks again and then dials Setting options 1 255 s Step 1s Default setting 15s
30. dule SIM card and so on during SmartGate operation 8 2 CSD PC PC Data Transmission The CSD mode provides data transmission in the GSM network at the maximum transmission rate of 14400 bps It works like a classic connection of two modems AT commands ATD ATH ATA etc Connection can be made with another GSM modem or a PSTN modem Caution Data calls and fax calls from the PSTN come as voice calls the telephone line on SmartGate rings because an analog network is unable to distinguish a modem fax call Therefore it is necessary to have a special telephone number for incoming data and fax calls on the SIM card different from voice call numbers Multi numbering scheme The GSM network identifies a call incoming to this number as a data fax call and lets the COM serial interface ring 16 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 8 3 CSD or High Speed GPRS Data Connection to Internet To connect to the Internet install the faxmodem driver from the SmartGate CD ROM first Another possibility is to use the GSM provider s installation wizard in case it supports the SIEMENS GSM module installed in SmartGate SIEMENS MC45 46 or MC55 56 The installation wizard usually configures the telephone connection of the network too If you use manual installation you have set it properly Ask you GSM provider for Internet connection instructions because they can be different for e
31. e incurred as a result of SMS sending failure 15 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 8 COM Serial Interface The complete serial interface RS 232C on a 9 pin connector is identical with any external modem The transmission rate ranges from 1200 to 115200 bps SmartGate supports autobauding i e responds to an AT command at a rate identical with the AT command transmission rate and retains set on this rate The transmission setup must be 8 bits no parity and one STOP bit 8N1 SmartGate s central processor uses the same interface for establishing calls and so it must have the possibility to block an external serial interface all PC SW must provide transmission hardware flow control HW handshaking COM can be used for e Programming and monitoring e CSD PC PC data transmission e CSD or high speed GPRS connection to the Internet e SMS sending and receiving 8 1 Programming Monitoring Install the SmartGate PCManager software available on the included CD ROM into your PC The program is designed for SmartGate parameters programming It can read configuration data from the memory and store them in SmartGate Moreover all parameters can be saved in your PC file for backup or saving into another SmartGate system The SmartGate PCManager contains an easy monitoring tool too With this tool you can identify the GSM provider s name signal strength GSM mo
32. er of rings SmartGate transmits dial tone and green LED for line starts flashing 2 Dial the GSM subscriber number using DTMF The delay between dialed digits may not exceed 5 s programmable parameter The number is evaluated as complete after this timeout 3 A short delay follows the last dialed digit for SmartGate to await further dialing Then the dialing end is signaled and connection is established 4 Prefix of dialed number is compared with filled rows of FXO routing table The call is rejected or routed to GSM network according to the routing table 5 the called subscriber is available you can hear the ringing tone If not SmartGate hangs up 6 When the called subscriber answers the call a call is established The green Line LED is permanently on during the call 7 Hang up to terminate the call PBX sends busy tone to SmartGate s subscriber line SmartGate detects it and disconnects the GSM call 5 2 2 Incoming call from GSM network 1 The CLI is compared with filled rows of GSM routing table The call is rejected or routed to FXO interface extension line of PBX according to the routing table 2 SmartGate hooks off the line If there is filled in the Dial in parameter for given CLI SmartGate dials it using DTMF 3 The GSM subscriber hears the ringing tone from PBX if the automatic dial in function was applied if not he hears dial tone from PBX and he can dial required extension himself 4 The call terminat
33. established Any dialing during the BabyCall timeout cancels this function and a standard outgoing call can be made 5 1 5 ME Mobility Extension ME function takes place during ringing on FXS interface if SmartGate is programmed as DialThru gateway Fill in telephone number for ME function and number of rings to ME function start 1 SmartGate detects a ringing signal and immediately interconnects it to FXS interface the phone starts to ring 2 If there is no call connection before the pre programmed number of rings SmartGate simultaneously establishes call to GSM network Some timeout take place between GSM call establishing start and ringing of mobile phone 3 As long as SmartGate detects ringing on FXO interface connected analog and GSM phones ring 4 You can receive the call on analog line as well as on your mobile phone 5 During call received on mobile phone you can send FLASH to PBX for special PBX functions by preprogrammed DTMF code If you want repeatedly temporarily disable and afterwards enable the ME function fill in Password for ME activation disabling If password is filled in 1 Hook off the phone 2 For temporarily disabling the function dial the password and confirm by For activation the function dial the password and confirm by B9 3 Hang up 5 1 6 Tariff pulses 16 or 12 kHz SmartGate has tariff pulse transmitter on FXS interface You can use tariff pulses for outgoing call pricing SmartGate offer p
34. etwork and attached phone terminals You can connect terminal with FXO interface trunk line of PBX phone set answering machine etc to FXS interface on SmartGate connector with phone icon and terminal with FXS interface extension line of PBX to FXO interface on SmartGate connector with crossed out phone icon e You can establish data connections GPRS CSD and send receive SMS using SmartGate in combination with a PC and appropriate software e You can send an SMS to a pre programmed number using the SMS sending input e Analogue fax transmition on some models 1 2 Advantages of SmartGate Use e Call cost cutting the calls are routed to GSM or analog network according to their number prefix Route all GSM calls from PBX to SmartGate to save a lot on PSTN GSM calls e Easy installation you can easy program SmartGate as you need with enclosed SW e You get all you need in the delivery your SmartGate delivery contains all you need to operate the system the power supply adapter telephone cables PC serial cable SMS input connector CD ROM with software e Solution for sites without telephone lines such as mountain chalets exhibitions conferences etc e DialThru technology all your calls will be routed most cost effective way e Mobility Extension you newer miss an incoming call from analog network Incoming call will ring on connected phone and on your mobile phone too e CLIP SmartGate is equ
35. f Hook FXS line and dial PASSWORD plus to disable the function Off Hook FXS line and dial PASSWORD plus to activate the function again Setting options 0 8 characters 0 9 Default setting blank Prefix Dialed number prefix identifying the call type Other numbers line is used for calls with prefixes that are not included in the table Setting options 0 16 characters 0 9 Default setting blank Call enable This parameter allows bars calls with corresponding prefixes Setting options YES NO Default setting YES Number length The parameter defines the expected length of dialed number It enables to start dialing into GSM or FXO interface immediately after the last digit is dialed If the telephone number to be dialed is shorter a timeout is respected The 0 setting means that the function is disabled Setting options 0 3 15 Setting step 1 Default setting 0 End with This parameter enables to establish the call when a is received The character is removed from the dialed number If a should be part of the dialed number this function cannot be used for the given prefix Setting options YES NO Default setting NO Remove The Remove parameter is used for automatic call routing A defined count of digits prefix is removed from the number beginning Setting options 0 20 Setting step 1 Default setting 0 32 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTG
36. fax message to GSM Before destination number dial code 01 to inform the Gateway that the call is a fax call Receiving a fax message from GSM It is recommended to activate separate fax number on your SIM card multinumbering scheme Fax messages should be routed to this number the message will be than received as fax message automatically If the fax number is not activated the call from analogue network routed to your GSM number is not detected as fax call and is routed via the analogue channel of GSM network and the connection is not successful In this case it is possible to activate fax engine in the gateway to receive the next call as fax call Hook off dial the code 9901 and hook on again After this the gateway is prepared to receive a fax call from analogue network After receiving the fax this setting is suspended 14 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 7 SMS Sending Input This universal input is intended especially for reporting alarm or error statuses of any equipment provided with the appropriate contact a relay contact e g By activating this input electric input pin interconnection you send one SMS to one pre programmed telephone number Caution Do not use in life supporting or property protection applications because of the character of SMS service and SmartGate equipment The manufacturer shall not be liable for health and property damag
37. gard to potential SmartGate memory data structure change the PCManager and SmartGate are matched according to versions A PCManager version can be used for SmartGate programming that differs from the SmartGate version by a letter following the version number e g 1 00A The PCManager itself identifies this fact and notifies you 9 1 4 Monitoring Monitoring is active when SmartGate is in operation and registered to the GSM network If SmartGate is not registered to GSM the COM is blocked and no monitoring can be made This simple informative function helps you identify e The GSM module type and IMEI ID e The SIM card IMSI ID and selected SMS service centre necessary for SMS sending e The GSM provider s name and signal strength received by SmartGate this information helps you find the optimum signal location the information is updated in 10s intervals e The SmartGate line status standby outgoing call incoming call including telephone number The COM is locked during dialing and incoming call ringing so the PCManager reports COM blocking Monitor iate connected SIEMENS 55 REVISION 02 06 52021001 946045 23001 4000028981 420603052000 T Mobile Cz 23001 None 21 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 9 2 Parameter Tables All programmable parameters are listed in this section Each parameter is accompanied with the unit used descr
38. ialed All other calls are enabled and they 28 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE are routed to GSM network Their tariff is one impulse every 30 second and you can accelerate connection establishing by dialing of a after the dialed number Prefix Dialed number prefix identifying the call type Other numbers line is used for calls with prefixes that are not included in the table Setting options 0 16 characters 0 9 Default setting blank Call enable This parameter allows bars calls with corresponding prefixes Setting options YES NO Default setting YES Route to This parameter defines FXS call routing Setting options GSM the call is routed to GSM network only FXO the call is routed to FXO interface only GSM FXO the call is primary routed to GSM network In case of GSM network error it is routed to FXO interface FXO GSM the call is primary routed to FXO interface In case of FXO interface error it is routed to GSM network Default setting GSM Number length The parameter defines the expected length of dialed number It enables to start dialing into GSM or FXO interface immediately after the last digit is dialed If the telephone number to be dialed is shorter a timeout is respected The 0 setting means that the function is disabled Setting options 0 3 15 Setting step 1 Default setting 0 End with This parameter enables to establ
39. igned for the contact of relay connected between the input pins The input is activated by contact closing pin interconnection A transistor switch or logic signal can be used too The pin near the telephone line connector is connected to GND of the device the second one is active Please respect the loop current polarity There is over voltage protection up to 12V DC there 2 8 PC Connection You have got a serial cable for PC connection It is a modem cable where all of the 9 pins are 1 1 interconnected in case you want to use another cable If you use a longer cable make sure it works properly There may occur errors at higher transmission rates 5 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 3 SmartGate Status Indication 3 1 Indication LEDs Name Meaning e Light SmartGate is powered e Powersupply e Flashes once in 2s HW error contact the manufacturer Light registered into GSM network Flashes once in 1s not registered SIM card inserted Flashes once in 3s not registered SIM card not inserted Flashes 4 times quickly enter your PIN Flashes 8 times quickly enter your PUK Flashes quickly continuously all functions are blocked Your SIM doesn t correspond to the GSM operator lock e Qo GSM network e No light standby Orange for FXS interface e Flashes quickly line off hook or ringing e Light call FXS GSM 9
40. ion is the same as in case of outgoing call 12 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 5 3 Gateway for trunk line of PBX Outgoing and incoming call establishing procedures is for illustration described for analog phone connected to FXS interface The rules for call establishing in case of trunk line connection are the same you have to program your PBX to route GSM calls to SmartGate We strongly recommend to check SmartGate s function by connecting a phone in case of interconnection with PBX trunk line 5 3 1 Outgoing call on FXS interface 1 Hook off the telephone you can hear the dial tone and the orange Line LED starts flashing 2 Dial the required GSM subscriber number SmartGate receives tone dialing DTMF by default If your telephone transmits pulse dialing only program SmartGate to receive pulse dialing The delay between dialed digits may not exceed 5s programmable parameter The number is evaluated as complete after this timeout 3 A short delay follows the last dialed digit for SmartGate to await further dialing Then the dialing end is signaled and connection is established 4 Prefix of dialed number is compared with filled rows of FXS routing table The call is rejected or routed to GSM network according to the routing table 5 the called subscriber is available you can hear the ringing tone If not you can hear the busy tone or any of the GS
41. ipped with the FSK based CLIP feature so if a terminal capable of receiving the CLIP is used you know the caller s number e Quick data connection SmartGate transmits data using the high speed GPRS connection GPRS class 10 max 85 6 kbps e SMS sending input simply send an SMS to a pre programmed number by closing the contact Recommended for easy supervision simple securing etc e Radiation hazard minimization you are not exposed to a direct effect of the antenna RF electromagnetic field while telephoning as opposed to mobile telephones e Full GSM coverage SmartGate is available as tri band for European markets 900 1800 and 1900MHZz and as tri band for the American market 850 1800 and 1900 2 1 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE e 2 Installation 2 1 Proper Location e SmartGate is designed for vertical mounting on suspension holes use the mounting pattern This position is the best for signal reception because a vertical antenna is used SmartGate can be operated in the horizontal position too where the GSM signal is good or with antenna connected on coax cable e Install SmartGate with respect to the GSM signal strength check the signal strength using the PCManager e Place SmartGate out of range of sensitive devices and human bodies for electromagnetic interference reasons e SmartGate can disturb other telecommunication systems
42. iption of SmartGate s behavior setting options setting step and default value value after initialization Identical texts are displayed as help hints in PCManager program 9 2 1 Telephone interface FXS parameters Type of dialing Select the dialing type to be received by SmartGate on the FXS interface SmartGate accepts only the selected type of dialing ignoring the others Setting options DTMF SmartGate receives tone dialing only Pulse SmartGate receives pulse dialing only Default setting DTMF Timeout for dialing end recognize s Timeout during which SmartGate waits for further digits to be dialed It starts to establish connection when this timeout passes Setting options 1 255 s Setting step 1s Default setting 5s Minimal On Hook ms The minimum line current break that SmartGate evaluates as hang up Setting options 100 25500 ms Setting step 100 ms Default setting 500 ms Beep after dialing end Select a beep to signal the end of dialing beginning of outgoing call establishing Setting options YES NO Default setting YES Dial tone frequency Hz Setting of frequency frequencies of dial tone Setting options 1 3400 Hz Setting step 1Hz Default setting 425 Hz 22 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Dial tone cadence This tone is generated after Off Hook in case SmartGate is ready to accept dialing Setting options Continuous
43. ish the call when a is received The character is removed from the dialed number If a should be part of the dialed number this function cannot be used for the given prefix Setting options YES NO Default setting NO Remove The Remove parameter is used for automatic call routing A defined count of digits prefix is removed from the number beginning Setting options 0 20 Setting step 1 Default setting 0 29 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Add The Add parameter is used for automatic call routing A defined string prefix is added to the beginning of the number to be dialed Setting options 0 16 characters 0 9 Default setting blank Extra tariff Pseudo tariff metering setting tariff is based on call duration for GSM calls Connected PBX must send tariff metering pulses for FXO calls The Extra tariff parameter defines transmitting of fixed quantity of tariff pulses after call start This parameter sets minimal call cost Setting options 0 255 Setting step 1 Default setting 0 Tariff s Pseudo tariff metering setting tariff is based on call duration for GSM calls Connected PBX must send tariff metering pulses for FXO calls The Tariff parameter sets the call cost according to call duration Set how often in seconds do you want to transmit pulses Smaller number means more expansive call 0 means not to transmit pulses according to c
44. iven prefix e Accelerate connection establishing by allowing to terminate dialing with a e Modify the number to be dialed by removing and or adding prefix e Set tariff metering for the given prefix Routing tables x FXS routing table FXO routing table GSM routing table oo No GSM 0 No 0 0 0 2 00421 Yes 14 No 0 0 0 Yes GSM 0 No 0 0 0 Yes GSM 0 No 0 0 0 5 Yes GSM 0 0 0 0 6 Yes GSM 0 0 0 0 Yes GSM 0 0 0 0 6 Yes GSM 0 No 0 0 0 Yes GSM 0 0 0 0 Yes GSM 0 0 0 0 Yes GSM 0 No 0 0 0 E Other prefixes Yes GSM 0 Yes 0 0 30 Every table line includes a phone number prefix of variable length and other parameters The parameters define SmartGate s behavior in case the beginning of the dialed number matches this prefix on the same table row The table contains 120 rows for up to 120 different prefixes There may be exceptions to the rule a number may start with the same digits but has to be served in a different way Any table row that starts with the same prefix followed by one or more digits is considered an exception of the line with shorter prefix Remember to complete the Other prefixes line for a number whose prefix is not found in the table An example in the figure shows how to bar all international calls with the exception of calls to Slovakia Calls to Slovakia are routed through FXO interface and the call is established immediately after 14 digits are d
45. nd so it is advantageous to connect a terminal that is able to display or process the CLI You must activate the function on SmartGate 2 5 4 Gateway for both trunk and extension lines of PBX SmartGate is very flexible thanks to his three routing tables You can connect trunk and extension lines of one PBX to proper connectors on SmartGate You can program the complex as follows outgoing calls from PBX will be routed through trunk line to GSM network Incoming calls from GSM will be routed to extension line of PBX This configuration is suitable for PBX s with no capability of dial in on trunk lines 4 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 2 6 Power Supply Connection SmartGate is powered with 10 16V DC Where a source other than the included power supply adapter is used the voltage range and polarity shown on the SmartGate power supply connector have to be maintained For backup power supply you can use EnergyBank backup source with accumulators Do not power on the supply until the antenna is connected to SmartGate to avoid the GSM module damage 2 7 SMS Sending Input Connection You have got a special connector for easy connection to SmartGate The connector is equipped with screwing clamps to connect wires from a switching contact device to be monitored The other connector end can be connected to the respective SmartGate panel connector The input is des
46. number of rings Routing table FXO is disabled gateway for extension line of PBX SmartGate detects incoming ringing and Off Hook the line after programmed number of rings if it is possible to make call to GSM SmartGate generate dial tone and after dialing takes an action according to FXO routing table Setting options FXS DialThru gateway GSM gateway for extension line of PBX Default setting FXS DialThru gateway ME number If you program SmartGate as DialThru gateway fill in telephone number for ME function SmartGate starts to establish GSM call to ME number after defined number of rings Then you can receive incoming FXO call on telephone line or in GSM network Blank parameter disables ME function Setting options 0 16 characters 0 9 Default setting blank Number of rings to ME If you program SmartGate as DialThru gateway and ME number is filled in SmartGate starts to establish GSM call to ME number after defined number of rings Then you can receive incoming FXO call on telephone line or in GSM network Setting options 0 255 Step 1 Default setting 1 31 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE Password for ME activation disabling If you program SmartGate as DialThru gateway and fill in ME number function ME is active If you fill in password for ME activation disabling you can activate disable function ME without PC programming Of
47. ors Operating temperature Operating status signaling 170 x 130 x 45 mm 0 C to 45 C 3 LEDs on GSM network line 2006 2N TELEKOMUNIKACE a s 43 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299
48. rogramming and saving If you only save data after PCManager start all parameters except the PIN and service password in the SmartGate memory will have default values Caution The PIN and service password can only be modified either manually or by full initialization 9 1 3 Upgrade The manufacturer responds to clients requirements with periodical firmware updating The current SmartGate firmware PCManager and User Manual are available on www 2n cz The latest firmware version is always included in every new PCManager installation Upgrading procedure Run the PCManager select the language for displaying texts on the right hand side Click on the CD ROM icon for data handling on the left hand side Click on the upgrade if SmartGate is not in its special programming mode you are invited to switch SmartGate off and on again 4 f there is more then one file in the PCManager directory chose one of them The upgrade takes place automatically Do not switch your PC or SmartGate off during the process of upgrading on Caution The PCManager checks the software version in SmartGate and the upgrade file If the version in the file is new everything is all right An identical or earlier software version is stored in SmartGate too but the PCManager requires confirmation to be on the safe side 20 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE e Caution With re
49. seudotariff only tariff metering doesn t correspond to real price of call tariff pulses are transmitted according to programmed parameters and call duration You must program specific parameters in FXS routing table to set tariff metering for different prefixes of dialed numbers Tariff metering is transmitted only during calls to GSM network Connected PBX must provide the tariff metering during calls to FXO interface You can also program SmartGate to transmit tariff pulses as call connect disconnect signaling if your PBX cannot receive telephone line polarity reversal signaling 11 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 5 2 Gateway for extension line of PBX Extension line of PBX is connected to FXO interface on SmartGate FXS interface remains unconnected You have to program parameter FXO call route to for proper function on FXO interface You can fill in some rows in FXO routing table to reject given calls for automatic call routing etc Fill in GSM routing table to route an incoming GSM calls to FXO interface It is necessary to set up conditions for call disconnect detection from PBX If SmartGate detects busy tone or continuous tone from PBX it disconnects the established GSM call 5 2 1 Outgoing call on FXO interface 1 SmartGate detects a ringing signal from PBX and if it is possible to establish GSM call it hooks off the line after preprogrammed numb
50. ssible e fthere are still problems use the antenna with coax cable SmartGate does not communicate with PC e Check the serial cable connection Check the COM number setting on PC Check the COM parameters 1200 115200 bps 8N1 SmartGate is not registered to GSM network A dialing or outgoing call establishing process takes place on SmartGate An incoming call is ringing on SmartGate 40 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 11 List of Abbreviations Access Point Name necessary for the GPRS service CLIP Calling Line Identification Presentation CLI Calling Line Identification e CSD Circuit Switched Data COM PC serial port DTMF Dual Tone Multifrequency tone dialing SmG SmartGate FSK Frequency Shift Keying Protocol for CLI transmission on telephone line FXO an interface electrically identical with a standard telephone opposite side FXS interface FXS a telephone interface allowing standard telephone connection opposite side FXO interface FW Firmware similar to SW a term for the central microprocessor program GSM Group Switched Mobile system the present standard digital mobile telephone network e GPRS General Packet Radio Service high speed data transmission for GSM networks HW Hardware an electronic device circuit board component etc in this context
51. t s If SmartGate is programmed as FXO gateway parameter defines time between line Off Hook and automatic call beginning if enabled During this timeout SmartGate waits for dialing that cancels the automatic call You can make standard call if the BabyCall function is enabled Setting options 0 255 s Setting step 1s Default setting Os Transmission volume See FXS interface parameters Reception volume See FXS interface parameters Mobility Extension FLASH code Fill in DTMF code to enable GSM FLASH function If SmartGate receive DTMF dialing corresponding to filled code during GSM FXO call it generates FLASH to FXO interface Setting options 0 4 characters 0 9 Default setting blank FLASH length ms Time of current loop interruption line On Hook during FLASH Setting options 100 1500 ms Step 100 ms Default setting 100ms 27 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 9 2 3 Routing Parameters All parameters related to the dialed number and call routing are arranged in three routing tables Each table pertains to one interface FXS FXO and GSM FXS routing table According to the prefix of dialed number on FXS interface you can e Bar the number to be dialed the calling subscriber hears the busy tone e Route the call to GSM network or to PBX through the FXO interface e Accelerate connection establishing by knowing the number length for the g
52. the DTMF You can cancel the wrong PIN by entering of a 8 or you can hang up before sending B9 To confirm enter a 09 If you hear the busy tone in a while a few seconds you have entered the PIN correctly Hang up and wait for registering to the GSM network 5 f you hear the PIN tone again in a while you have entered a wrong PIN Re enter the PIN correctly 6 If you hear the PUK tone in a while you have entered a wrong PIN and the SIM card is blocked Use the mobile phone to unblock the SIM card 02 PIN entering a telephone line connected to FXO interface if SmartGate is used as gateway for extension line of PBX 1 Dial the SmartGate s extension number on your PBX SmartGate detects ringing and after off hook generates the PIN tone 2 Enter the PIN using the DTMF You can cancel the wrong PIN by entering of a 8 or you can hang before sending B9 To confirm enter a 09 If SmartGate after a while a few seconds hangs up you have entered the PIN correctly 5 f you hear the PIN tone again in a while you have entered a wrong PIN Re enter the PIN correctly 6 If you hear the PUK tone in a while you have entered a wrong PIN and the SIM card is blocked Use the mobile phone to unblock the SIM card RC A correctly entered PIN is stored in SmartGate s memory as if you had programmed it using the PCManager The PIN will be entered automatically upon every SmartGate power up 8 VolPon www
53. the PCManager and select the language for displaying texts on the right hand side Click on the CD ROM icon for data handling on the left hand side Load data from SmartGate if SmartGate is not in its special programming mode you are invited to switch SmartGate off and on again 4 Click on the programming table icon on the left hand side 5 The parameters are arranged according to their functions in the tables Set all parameters you want to change If you point at a parameter with the mouse help is displayed Click on the CD ROM icon again for handling data Save data into SmartGate if SmartGate is in its special programming mode you are invited to switch SmartGate off and on again Co N NO 9 1 2 Further Data Handling Options In addition to the SmartGate memory settings can be saved in a PC file and reloaded into the PCManager This is recommended for backing up of current configurations or saving the same configuration in another SmartGate unit Caution The table Security includes the PIN code and service password These parameters have a special handling They are not saved in a PC file for security reasons If you load a PC file into the PCManager and then into SmartGate the PIN and service password should not change unless you change them manually before saving Caution All tables are filled in with default values after PCManager start It is recommended to load data from SmartGate before parameters p
54. ven PIN fails to match the SIM it is deleted automatically If entered via a telephone line upon SmartGate start the PIN is stored automatically Setting options 0 4 8 characters 0 9 Upon full initialization blank 39 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE e 10 Troubleshooting No LED is on after power up e Check the power supply All LEDs are on No call is currently in progress e SmartGate is the special PCManager based programming mode exit the PCManager to reset SmartGate e Try to switch SmartGate off and on the LEDs should go off in 3s and signal the status of SmartGate SmartGate does not register to GSM e Check the SIM card e Check the PIN entering e Check the antenna connection e Select a place with a good GSM signal No tone can be heard after line off hook e Check the telephone line connection e SmartGate is not initialized properly upon start approx 10s after power up e SmartGate is not supplied with power SmartGate keeps transmitting a tone during dialing not receiving the dialing e Select the correct dialing type DTMF or pulse Voice disturbance on telephone lines during GSM call e Check signal strength using PCManager monitor Place SmartGate to place with good GSM signal e Check distance between telephone lines and SmartGate s antenna Distance between antenna and other telecommunication systems should be as long as po
55. voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 4 3 Automatic PIN Entering You need not enter the PIN upon power up if it is stored in SmartGate it is entered automatically This function is useful in case of power failure SmartGate is operable in a short time after power recovery without any intervention by the operating staff Caution One PIN entering option is exhausted by the attempt to enter the PIN automatically upon SIM card or PIN change If wrong the automatically entered PIN is cleared from the internal memory to avoid another false attempt upon next power on There are still two manual PIN entering attempts after such unsuccessful automatic entering To prevent the unsuccessful automatic PIN entering delete or program properly the SmartGate PIN using the PCManager in the case of SIM card change 9 VolPon www voipon co uk sales voipon co uk Tel 44 0 1245 808195 Fax 44 0 1245 808299 SMARTGATE 5 Voice function Outgoing and incoming call establishing procedures is for illustration described for analog phone connected to FXS interface and extension line of PBX connected to FXO interface on SmartGate In case of other equipment connection please check SmartGate s function by connecting a phone Suppose that a SIM card has been inserted the PIN code entered or not required the antenna connected and SmartGate registered to GSM network the GSM network LED is perm