1. Anemometer Custom Exit If using a custom anemometer type 5 and press Enter then enter the conversion factor from Hertz to meters per second or any other preferred unit of measure Anemometer 1 1 006 Enter value for m s per Hz Enter the required value and press Enter The same menu will then appear for Anemometer 2 A2 3 3 2 3 Date and time setup Press 3 and Enter to access the date menu Date dd mm yy Enter the date in the format shown and press Enter Press 4 and Enter to adjust the time Note that if batteries are Enter time in 24h hh mm ss removed date and time will be reset Enter time in the format shown and press Enter 3 3 2 4 Custom North point setup The wind vane should normally be mounted with its index marker facing North In this case the LeWL does not need any wind direction calibration For installations where it is not possible to mount the vane facing north the LeWL s wind direction calibration must be used To do the wind vane calibration follow the steps below Ensure the wind vane is mounted in its final installation position then manually point it to North Press 6 and Enter on the terminal to enter wind vane calibration mode Wind direction offset nnn degrees Point Wind Vane to North and press Enter when ready nnn is the current offset in degrees heading After pressing Enter a new value will be displayed Installation Manual Page 20 Logic Energy Ltd Ins
2. 00 4X8 logicenergy LIVE MONITORING LeWL Wind Logger Installation amp User Guide LeWL v7 Dec 2014 Revision Sheet i as Date Revision Description 21 04 2009 23 06 2009 Rev 2 21 04 2009 Manual for LeWL version 5 Rev 5 23 06 2009 Adaptation for LeWL version 5 menu Rev 6 18 11 2009 Lewl_setup application Rev 8 07 07 2011 Menu setup changes Rev 9 07 09 2012 Layout changes setup and sensor review Rev 7 10 04 2009 New contact details Rev 10 10 12 2014 Updated for LeWL hardware version 7 and firmware v7 0 3 Installation Manual Page 2 Logic Energy Ltd Important Notice You must read and agree to the License Agreement and conditions of use before you commence using the product If you do not agree you must return the whole package to the point of purchase Disclaimers Logic Energy Ltd assumes no responsibility nor liability for damages consequent to the user of this product This document is being supplied to you solely for information purposes and may not be reproduced or distributed to any other person or parties in whole or in part for any purpose The information provided in this manual is intended for instructional purposes only This document is subject to change without notice and does not represent a commitment on the part of the manufacturer Every effort has been made to make this guide as complete and as accurate as possible but no warranty or fitness is implied T
3. 1 4 Custom North point setup The wind vane should normally be mounted with its index marker facing North In this case the LeWL does not need any wind direction calibration For installations where it is not possible to mount the vane facing north the Reset North Indexing option must be used to calibrate the North direction To set the North calibration select Yes and write the setup file as normal Before inserting the SD card into the LeWL and powering up the LeWL manually point the vane to North and hold it there Then insert the card and power up the LeWL and it will apply the north calibration NOTE After North calibration is done make sure this option is set to No in future to avoid re calibration when the wind vane is in operation The LeWL will automatically change this part of the setup file but is good practice to check it You can also use the Serial Port to perform the North calibration 3 3 1 5 Applying the settings to the LeWL After selecting and setting up all the parameters for the LeWL the final step is to write the setup file to the SD card Click the Write setup file button and the parameters will be written to the setup txt file on the SD card You can verify the selected parameters for the LeWL by viewing the setup txt file on the SD card after clicking the Write Setup file button Installation Manual Page 17 Logic Energy Ltd Installation and Setup After the new setup file
4. date and time is correct Do NOT leave the serial cable permanently connected This will shorten battery life considerably Installation Manual Page 23 Logic Energy Ltd Installation and Setup 5 SPECIFICATIONS 5 1 Physical Dimensions Enclosure LxWxH 160 x 80 x 55 mm excluding cable gland 195 x 80 x 55 mm including gland Mounting holes 148 x 50 mm centres 4 5 mm diameter Cable gland M20 gland with split seal insert for 3 6 mm cable diameter 5 2 Technical Specification Memo MicroSD flash card FAT16 32 2GB max Power 2 x Alkaline batteries 1 5v C size Operating Temperature 15 C to 50 C Maximum frequency input 200Hz max internal pull up to suit reed switch dry contact Sensor Inputs 2 anemometer pulse inputs 1 wind vane 1 NTC temperature Communications RS232 4800baud Logging Interval 1 minute or 10 minutes Output data format CSV ASCII format data file Readings Average wind speed for each anemometer m s Maximum wind speed for each anemometer m s Standard deviation for each anemometer m s Wind direction degrees 16 bins Temperature degrees Celsius Housing Sealed polycarbonate or ABS plastic case IP65 Weight approx 450 gm including batteries Installation Manual Page 24 Logic Energy Ltd Installation and Setup 6 TROUBLESHOOTING Installation Manual Page 25 Logic Energy Ltd Installation and Setup Problem Data is not written to the memory card Solu
5. is ready insert the SD card into the LeWL s card slot as soon as possible The LeWL will detect these new settings and save the parameters After new settings have been changed you should see the green LED on the LeWL blink e One long flash then 2 shorter flashes before going into normal operation indicates new settings have been stored successfully e Any other sequence such as rapid flashing indicates that the parameters have been rejected Please check the setup txt file or LOG txt file Status LED MicroSD card slot and status LED As a secondary check to ensure the new parameters have been successfully setup after the LeWL finishes writing to the SD card indicated by the status LED remove the SD card and open the LOG TXT file You will find a log of all the changes done over time with your most recent change as the last one on the log Ensure that the date and time are correct as these are used in the log files created by the LeWL If the batteries are removed make sure the date and time are set again after replacing the batteries Installation Manual Page 18 Logic Energy Ltd Installation and Setup 3 3 2 LeWL Setup Menu via Serial Port LeWL has a built in menu system to allow for different configuration options Connect the LeWL to a computer using a male to male 9 pin RS232 serial cable Use the following settings in HyperTerminal TeraTerm or any similar terminal program The COM port number that you are
6. using Data rate 4800 baud Data bits 8 Parity None Stop bits 1 Flow control None To enter the setup menu when the LeWL is not logging simply remove the SD card insert the batteries and the menu will appear on the terminal The LED will stay ON continuously If the LeWL is powered and logging remove the SD card from the LeWL unit and the LED will start flashing Press M on your computer s keyboard You should see a menu like this 1 Set Log Interval 60 seconds 2 Anemometer Setup Al LE Pro A2 LE Pro 3 Set Date now 10 11 14 4 Sec ue now 16347319 6 Wind direction calibration Select option and press Enter Insert card and press Enter to start logging 3 3 2 1 Recording Interval setup Type 1 and press Enter to change the averaging periods to write to the memory card 1 10 secs This setting is for testing purposes only 2 c Ji aan 3 10 min 4 ae currently 60 seconds Select your preferred timing option 1 2 3 4 and press Enter by default it is set to 1 minute average 3 3 2 2 Anemometer type setup Press 2 and press Enter to access the variables assigned to each sensor Select from the list the anemometer you are using Installation Manual Page 19 Logic Energy Ltd Installation and Setup ANEMOMETER Al LE Pro Select type 1 Anemometer 1 LE Vortex 2 Anemometer 1 LE Pro 3 Anemometer 1 PCE KWG1 4 Anemometer 1 Raw Hz 5 il 6 D
7. 451 012 o ol ol 3410 Date Date of this data DD MM YY format Time Time that this data was recorded 24h HH MM SS format Direction Wind direction heading in degrees 0 to 360 Temp C Temperature in degrees Celsius if NTC temperature sensor connected Wind1avg Average wind speed in this interval for A1 input meters second m s Wind1max Maximum wind speed recorded in this interval for A1 in m s Windistd Standard Deviation of wind speed in this interval for A1 in m s Wind2avg Average wind speed in this interval for A2 input meters second m s Wind2max Maximum wind speed recorded in this interval for A2 in m s Wind2std Standard Deviation of wind speed in this interval for A2 in m s Batt V Battery voltage For 10 second logging interval data is stored in daily files For example 01 08 14 CSV contains data for 1 August 2014 The LOG TXT file contains details of the configuration done on the LeWL logger date time of the day a new configuration was done recording interval number of anemometers the conversion factors of the anemometers and wind direction offset 10609654 aUysadios5ubs Ae abaco cence a 05Sc0oei Semsreuwe IbcDSSIS SEIS WD cesset Installation Manual Page 22 Logic Energy Ltd Installation and Setup 4 2 Data on the Serial port If you have the LeWL serial port connected to the PC the terminal screen should display a line of data each time it logs to the SD card 10 seconds 1 minute or 10 mi
8. 7 Anemometer 1 model 29 3 1 2 3 Today 12 12 2014 Pro s Anemometer 2 model Anemometer 2 model Pro Y Pro LE Re set North indexing Re set North indexing C Yes C Yes No G No Write setup file Write setup file Changing the date Changing the time Ensure that correct time and date values are set as these control the date time in the log files created by the LeWL 3 3 1 2 Recording interval setup The LeWL wind logger will continuously sample the sensors and store the collected values onto the SD card every 1 minute or 10 minutes The default value for the recording interval is 1 minute and this is the recommended setting for short or medium term data logging Alternatively you can select 10 minutes For long term logging 1 minute interval is recommended The 10 second interval has lower accuracy and should only be used for testing purposes Installation Manual Page 16 Logic Energy Ltd Installation and Setup 3 3 1 3 Anemometer type setup Set the type of anemometer for the A1 and A2 inputs to match the installed anemometer s typically Vortex Inspeed Vortex or Pro Davis Vantage Pro If a custom value needs to be entered please use the serial port interface and setup menu Anemometer 1 model Pro Davis Pro Anemometer Vortex Vortex Anemometer KGW Thies Small Wind Sensor ___________ Not used provides raw Hz values 3 3
9. Sensor Connection tede e rece e cadat e Dee on aide T Oe ce Leu e desear ee ed egi 12 34 3 Powering the LEVEL zzz cerent eL ennemie 13 3 2 Operating Modes rhe kno noD nad sia ne Fe nen n D i e a rw eR RR ER 14 3 3 L gger SOUP aaa ala 15 3 3 1 LeWL Setup via the SD card i 15 3 3 1 1 Date and time setUp r dA 16 3 3 1 2 Recording interval set p i iel aci 16 3 3 1 3 Anemometer type setup similaire ecc esL Ra tete etat 17 3 3 1 4 Custom North point Setup alata ta oet Eee EP t Ete hates De E bebe ia ins 17 3 3 1 5 Applying the settings to the LeWL iii 17 3 3 2 LeWL Setup Menu via Serial Port 19 3 3 2 1 Recording Interval Setup iiec ret ette o oed ee eei e Do tiep nio Beta ee PE EPA eR 19 3 3 2 2 Anemome ler type setup pe pbi te pe ian Pte ent te Hte eade eeu sl buts 19 23 3 2 3 Date and time setup ie ien git trece EO ead ee af eese bet ges eh p ipe eaa 20 23 39 2 4 Custom North pont Setup tit 2 pret One p IP terr SR esee E ebria visitas 20 4 DATA EXTRACT O N a ria et aaa a etd Avi init 21 4 1 Data on the MicroSD Card i csesescasescecsevessestscessssccscseccesnarsiesenseaeessasessocctscteosstesenasenvenrs 21 4 2 Data on the Serialiport anice aiar 23 S SPECIFICATION S irinse nanena inaen ne Nra eaaa iaia ti 24 Dil Physical Dimensions cages aaa 24 5 2 Technical SpeCiti Cation ess icccccssicsccsccccssscscdcecsvavanssestexsusscsecodaccscesctuessvensesSee
10. eWL should never be removed while the unit is in operation unless indicated by this manual If for any reason the cover has been removed it should be replaced before operation begins A service of the unit should be carried out only by an authorised Logic Energy service centre or Logic Energy authorised engineer 1 2 Disclaimer Under no circumstances will Logic Energy be liable for any direct indirect consequential or incidental damage including loss of profits business interruption and loss of data arising out of the use or the inability to use the software or hardware however caused save to the extent that such liability is not capable of exclusion at law These limitations of liability apply even if Logic Energy or a third party reseller have been advised of the possibility of such damage occurring Installation Manual Page 6 Logic Energy Ltd Introduction INTRODUCTION Installation Manual Page 7 Logic Energy Ltd Introduction 2 INTRODUCTION 2 1 System Overview LeWL is an automatic stand alone data logger that provides flexible and powerful data logging capabilities specifically designed for the Energy Industry LeWL features 2 digital pulse inputs and 2 analogue inputs LeWL works with various anemometers and wind vanes in order to log real time wind speed and wind direction data onto a MicroSD flash memory card Each data record has a date time stamp when stored on the memory card Data is stored as CSV comma
11. es ineduedverstseine 24 6 TROUBLESHOOTING iiieii Tarnai amaaa a aan aaa anea aaea Ea dossvesssvebeduecedesacdeeveadscessestcetess 25 T WARRANT Y E E E ella E E E P E E et sks 27 Installation Manual Page 4 Logic Energy Ltd General Information GENERAL INFORMATION Installation Manual Page 5 Logic Energy Ltd General Information 1 GENERAL INFORMATION 1 1 Safety Contact with AC electrical mains can cause a severe electric shock and could be lethal Never remove the cover from LeWL if you are not sure what you are doing Follow the set up instructions in this manual with care to ensure all electrical connections are made properly Do not connect any equipment to the battery supply until you have properly connected all the other leads Never push anything into holes slots or other openings in the LeWL unless specifically detailed in this document All Logic Energy products have been designed with ease of use in mind Caution Do not use or store the LeWL device without its cover lid and or open gland in hot cold damp or dusty places as this could affect the units performance and may prove to be a fire hazard Always ensure the lid is securely fastened and the gland is sealed and pointing downwards for reliable operation Do not put anything on the LeWL device that could cause water damage e g drinks plants etc Do not place the LeWL on top of a unit which emits heat The cover of the L
12. he author and the publisher shall have neither responsibility nor liability to any person or entity with respect to loss or damages arising from the use of information contained in this guide Logic Energy Ltd accepts no responsibility or liability for errors omissions or misleading information that may be contained in this manual Copyright This manual is copyrighted by Logic Energy Ltd All rights are reserved This document may not in whole or in part be copied photocopied reproduced translated or pre produced on any electronic medium or machine readable form without prior consent 2007 2014 Logic Energy Ltd All rights reserved Contact Details Logic Energy Ltd 1 Ainslie Road Hillington Park Glasgow G52 4RU Scotland UK Web www logicenergy com Installation Manual Page 3 Logic Energy Ltd TABLE OF CONTENTS 1 GENERAL INFORMATION iii 6 ti Safend 6 1 2 Disclaimer 6 2 INTRODUC TON men ilaele aaa eas 8 2 1 System OVER VIGW vow nia ricada ae aaa 8 2 2 Acronyms and Abbreviations nnneeennnnnneens 9 3 INSTALLATION AND SETUP 2 ccsicistisesccesi costa vedsieccesesacsvatucoecessiceasccscasectesesedvivetuearscossauis 11 3 1 Hardware Installation 1 tinere ceccstedecsesasssstasaeceacesstedsccestaacecodsesiveaaes 11 3 1 1 Mounting the LOW Lr ssi i cete etre e ER ERR AT aaa 11 3 1 2
13. lation Manual Page 11 Logic Energy Ltd Installation and Setup 3 1 2 Sensor Connection LeWL has 2 digital pulse inputs for anemometers 1 analogue input for the wind direction sensor and an optional analogue input for an NTC temperature sensor For a list of compatible wind sensors please visit http shop logicenergy com The connectors are labelled on the circuit board See Fig 3 for connector layout From left to right V Battery positive power red Battery negative power black Common ground for NTC NTC temperature sensor SvLGSsSsSseeEvcve Common ground spare Common ground wind vane Wind vane signal Wind vane power supply Common ground anemometer 2 Anemometer 2 signal Common ground anemometer 1 Anemometer 1 signal o0 OO OO BO Anemometer pulse LEDs 20 For Pro D anemometers with a pre fitted modular jack connector disassemble the cable gland and pass the anemometer cable through the nut and the split seal gland then though the gland into the LeWL and plug the connector into the socket on the circuit board Reassemble the gland and tighten so that it seals onto the cable Pro D cable gland assembly Assembled Pro D cable Assembled Vortex cable Other anemometers and Pro D without a connector connect to the LeWL via the terminal block Pass the cable s through the gland and strip the insulation from the cable ends Connect the anemometer signal wire to input A1 and A2 if u
14. lkaline type These will give longer life especially at low temperatures Ensure that the MicroSD memory card is properly inserted and does not have large amounts of data stored on it Do not use the 10 second logging interval for normal long term logging as it uses more power Ensure there are no short circuits in the sensor connections and that the sensors are working correctly Installation Manual Page 26 Logic Energy Ltd Installation and Setup 7 WARRANTY Installation Manual Page 27 Logic Energy Ltd Warranty All products manufactured by Logic Energy Ltd are guaranteed against defective materials for a period of one year from the date of delivery to the original purchaser THE WARRANTY WILL NOT APPLY TO THE PRODUCT IF IT HAS BEEN DAMAGED BY MISUSE ALTERATION ACCIDENT IMPROPER HANDLING OR OPERATION OR IF UNAUTHORISED REPAIRS ARE ATTEMPTED OR MADE SOME EXAMPLES OF DAMAGES NOT COVERED BY WARRANTY INCLUDE BUT ARE NOT LIMITED TO BATTERY LEAKAGE BENDING OR VISIBLE CRACKING OF THE PCB WHICH ARE PRESUMED TO BE DAMAGES RESULTING FROM MISUSE OR ABUSE THIS WARRANTY DOES NOT COVER THE ACCURACY OF THE SENSORS CONNECTED TO THE LeWL WIND LOGGER OR THE ACCURACY OF THE DATA COLLECTED BY THE LeWL WIND LOGGER Logic Energy Ltd 1 Ainslie Road Hillington Page 28 Glasgow G52 4RU Scotland UK www logicenergy com
15. n after removing the memory card just replace the memory card in its slot Replace the SD card as soon as possible because LeWL will not be able to record data without the card To read the data from the memory card use a computer with MicroSD card reader or adapter Do not use a tablet or phone as these will format or put extra files on the card so it can be used for internal storage When the card is inserted into the reader adapter a new drive should appear on your computer with all the files that have been logged For 1 minute or 10 minute logging intervals files are archived by month Installation Manual Page 21 Logic Energy Ltd Installation and Setup gt Removable Disk E Jin xl File Edit View Favorites Tools Help ay Q ss Q gt JO Search 75 Folders gt 3 Xx E address e dga AUGO7 csy BiAuco7 xls al DECO xls X FEBOB xls 3 JANOS xls x JULO7 xls 3 JUNO7 xls 3 MAY07 xls NOVO xls SP OCT07 xls SEPO7 xls 11 objects 47 5 MB d My Computer p For example the file AUGO7 CSV will contain all the relevant data from August 2007 The first line row of the file shows the product name and software version The next line row contains the header name of the data value for each column LeWL v7 0 3 c Logic Energy Ltd 01 08 14 09 00 28 225 125 364 423 018 ol ol ol 341 01 08 14 09 01 28 225 122 321
16. nd replace batteries at least every 3 months for best performance Installation Manual Page 13 Logic Energy Ltd Installation and Setup 3 2 Operating Modes The LeWL has a green LED marked SD ACT to indicate its three operation modes The LED is next to the MicroSD card slot Status LED MicroSD card in Leu pa ABsaue 2160 UA ejected position NECI p MicroSD card slot and status LED LED off short flash every 5 seconds Normal logging mode This is the normal operation mode The LED is normally off and flashes briefly every 5 seconds to indicate status A single longer flash indicates writing to the memory card each 1 or 10 minutes Rapid continuous flashing MicroSD card not inserted Flashing LED indicates that the memory card has been removed and the logger is waiting for the card to be re inserted or for setup via the serial port A short burst of rapid flashing can also indicate that there is a problem with the memory card or the batteries are low Check that the memory card is properly inserted the card is compatible the power consumption of the card is not too high and the card does not have a large amount of data and files on it If the batteries are low the logger will not write to the memory card in order to avoid corrupting the card LED on solid Serial menu setup mode LeWL is in serial setup mode when LED is continuously ON A computer with a serial port is requi
17. nute intervals as shown below LO O8 14 16348320 LEO 217 701 9 56 0 84 6 68 903 079 2 26 This data can be interpreted as follows 10 08 14 Date in dd mm yy format 16 48 25 Time in 24h format 180 Wind direction in degrees 180 south Value increasing clockwise in 16 steps 21 7 Temperature in degrees Celsius 7 01 Average wind speed m s for A1 during measurement period 56 Maximum wind speed m s for A1 during measurement period 84 Standard deviation for A1 during measurement period 68 Average wind speed m s for A2 during measurement period 03 Maximum wind speed m s for A2 during measurement period 79 Standard deviation for A2 during measurement period 26 Battery voltage Note that 2 26 volts is very low and batteries should be replaced NI i KO E FS KO A rapid flashing LED at any time means there is a PROBLEM If you leave the serial cable connected you can confirm that the LeWL is working by seeing a line of the data written every log interval or an error message indicating the problem ALWAYS check that data is being recorded properly and the LeWL wind logger is correctly set up before leaving the unit on site To check for correct operation remove the SD card and check the data log file or connect a computer s serial port to the LeWL as indicated in Section 3 3 2 and wait for at least the first stream of data on the serial port Check the number of anemometer logged and the
18. pletely Browse to the SD card and double click on the lewl_setup icon to launch the setup program The setup window appears as shown below 7 Logic Energy Ltd Select date for LewL 05 12 2014 Select time for LewL 12 21 34 Recording Interval Anemometer 1 model Pro bd Anemometer 2 model Pro Re set North indexing C Yes No Write setup file LeWL setup software Installation Manual Page 15 Logic Energy Ltd Installation and Setup 3 3 1 1 Date and time setup Default date value When the setup application file is executed it automatically takes the date from the computer s clock Changing the date The logger s clock date can be changed by clicking the arrow to the right of the data box and selecting the date from the calendar that appears Default time value When the setup application file is executed it automatically takes the current time from the computer s clock Changing the time The logger s clock time can easily be changed by clicking the corresponding time unit hours or minutes or seconds and then clicking the up down arrows to change the value y Logic Energy Ltd 7 Logic Energy Ltd Select date for LeWL Select date for LeWL 12 12 2014 X 12 12 2014 EN December 2014 gt Select time for LewL 128522 24 25 26 27 28 29 30 1 2 3 4 5 Recording Interval 8 10 11 D 13 15 16 17 18 19 20 1 Minute Md 22 24 25 26 2
19. pressure water jets from any direction NTC Negative Temperature Coefficient thermistor an inexpensive and compact temperature sensor RTC Real Time Clock RS232 Standardised connection system for connecting a device to the serial port of a computer or terminal MicroSD Micro Secure Digital a small memory card available in sizes up to 2GB Installation Manual Page 9 Logic Energy Ltd 3 0 Installation INSTALLATION AND SETUP Installation Manual Page 10 Logic Energy Ltd Installation and Setup 3 INSTALLATION AND SETUP 3 1 Hardware Installation 3 1 1 Mounting the LeWL LeWL can be wall or pole mounted using the four holes provided inside each corner of the box These are underneath the lid Fig 1 as shown below Use screws to mount the LeWL to a backing plate or straps to fix the LeWL to a tubular mast Ensure that the gland is facing downwards for maximum weather protection Do not obstruct access to the lid This will need to be removed to access the microSD card and batteries Once the LeWL is in position and has been set up and started fasten the lid with the included screws Check that the lid seal is intact and the lid is securely fastened Be careful not to lose any of the screws or insert them cross threaded Gland facing down i Fig 2 Always make sure the logger is mounted with its gland facing down and the lid is securely fitted to avoid any possible water leaks Fig 2 Instal
20. red to setup the logger using this mode See section 3 3 2 for details The logger enters setup mode if it is powered up with no memory card inserted To start the logger in normal logging mode insert a prepared MicroSD card before connecting the batteries Installation Manual Page 14 Logic Energy Ltd Installation and Setup 3 3 Logger Setup LeWL offers two ways to set up the logging interval sensor factor date and time The configuration can be done via the setup program on the SD card or via a serial port menu Before being used LeWL must be configured with the correct date time logging interval and sensor factor All the configured values except date time are stored in non volatile memory LeWL will therefore continue its operation using the previous configuration unless re configured Date and time will reset if the logger is powered OFF Always set the date and time after replacing batteries 3 3 1 LeWL Setup via the SD card The LeWL wind logger can be easily configured by using the setup program called lewl_setup Microsoft Windows only on the SD card This stores the logger configuration in a file called setup txt file on the SD card and the LeWL reads this file when it is powered on or when the SD card is inserted This setup file can be also edited manually if necessary To eject the MicroSD card from the logger push gently in on the end of the card into the socket to unlatch it then pull the card out com
21. separated values files that are archived either by month or day depending on the pre set logging interval All data including settings are stored onto a MicroSD card up to 2GByte capacity This simplifies the collection of data all that is required is to remove the memory card from the LeWL and insert it into a PC card reader adapter All stored files can be accessed with a standard text editor or any spreadsheet program like MS Excel or OpenOffice or imported into analysis software The LeWL wind logger is powered by two C type alkaline batteries which provide up to 1 year operating time under normal conditions when logging on 1 minute intervals or higher 2x anemometer inputs Cable gland and Serial port for 1x wind vane input weatherproof data and setup 1x NTC temperature input enclosure Energizer BR ELETTEL Powered by two MicroSD memory card Connector for Pro D C type batteries for storing data files and anemometer for setup Installation Manual Page 8 Logic Energy Ltd 3 0 Installation 2 2 Acronyms and Abbreviations CSV A data format originally known as comma separated values CSV FAT16 Older version of the FAT file system used on smaller memory cards FAT32 File Allocation Table 32 bits a modified form of the FAT16 file system Hertz Frequency in cycles per second 1 hertz equals 1 cycle per second IP65 Ingress Protection rating 6 totally sealed against dust 5 Protected against low
22. sing 2 anemometers Connect the anemometer return ground shield wire to the nearest G common ground Use the A1 input if connecting only one anemometer When the logger is operating logging 2 LEDs next to the A1 and A2 inputs indicate anemometer activity These LEDs flash briefly every 5 seconds when anemometer output pulses are detected If there is no flash check the anemometer wiring and that the anemometer is working correctly Installation Manual Page 12 Logic Energy Ltd Installation and Setup Pro Anemometer G red A1 or A2 black D green D yellow Vortex Anemometer _ _ a G black Pro D and Vortex anemometer cable colours and wiring The LeWL must be configured to match the installed sensors Refer to section 3 3 3 1 3 Powering the LeWL LeWL uses two C type alkaline batteries Always use premium or industrial alkaline batteries as these provide the best battery life and reliability at low temperatures Remove the batteries when the logger is not in use Flat batteries may leak and damage the logger The logger will stop recording data to the MicroSD card when the batteries are getting low in order to prevent data corruption If the recorded data stops earlier than expected check and replace the batteries If the logger detects that the batteries are low when it tries to write data it will flash the status LED rapidly for a few seconds instead of the usual short single flash Check logger a
23. tallation and Setup The new offset value is nnn Store value Y N If it was intended to change the offset value press Yes Y y otherwise No N n to keep the old value After calibration of the wind direction the new value will be used only if you select Yes Yes New value nnn stored No Old value nnn used Once the above configuration steps have been completed put the SD card in its slot and press Enter Leave the serial cable connected and check the readings see Section 4 2 If the readings are satisfactory disconnect the serial cable with care The logger is now actively logging data Do NOT leave the serial cable connected for extended periods This increases the power consumption of the logger 4 DATAEXTRACTION The LeWL stores data in files on the SD card in CSV comma separated values format The data is also output on the serial port as it is logged to SD card 4 1 Data on the MicroSD Card Before removing the memory card ensure that LeWL is not writing to or has completed writing to the card To avoid data corruption the card should be removed quickly when the LED is off To eject the MicroSD card from the logger push gently in on the end of the card into the socket to unlatch it then pull the card out completely To insert the card push it all the way into the socket so that it latches into place Retrieve data on a monthly basis and keep backups of the data files To resume normal logging operatio
24. tion This is likely to be due to a corrupted memory card excessive memory card power consumption or flat batteries Some memory cards use much more power than others To guarantee a long battery life LeWL limits the current being supplied to the memory card We recommend using the memory cards supplied by Logic Energy Ltd The LeWL is compatible with MicroSD cards up to 2GB Problem The time and date has reset to zero Solution LeWL uses the batteries to keep its internal clock working If at any time the batteries are removed LeWL will reset its time and date to 00 Follow the instructions in the Logger Setup section to set the time and date Problem LeWL s green LED is flashing continuously Solution Make sure the memory card is properly inserted and the card is working correctly The LeWL is compatible with standard MicroSD cards up to 2GB Problem Wind direction is stuck at zero Solution Ensure that the wind vane wiring is correct and that there are no short circuits or open circuits at the terminals Check that the cable is not damaged Problem Wind speed is zero or wrong Solution Ensure that the anemometer wiring is correct and that there are no short circuits or open circuits at the terminals Check that the cable is not damaged Also check that the anemometer type is set correctly as this affects the speed calculations Problem The batteries go flat quite quickly Solution Ensure that the batteries are good quality a