1. the relevant scene Preset Value The dimmer can preset scene the object directly through 1bit data to transfer the preset scene or through 1bit data to let favorite scene to replace original preset scene There are two preset values per output there are two brightness values can be transfer for each preset value Such as in theater we need a relatively bright lighting effect when coming in we can through transfer the first brightness value to be achieved this effect when the movie starts playing we need a relatively dark lighting effect we can through transfer the second brightness value to be achieved We can return to the previous brightness value when the movie ended Staircase Lighting Function The dimmer offers the function of staircase lighting control besides the normal lighting control The staircase lighting function serves to switch off the lighting directly until dimming DOWN to 20 of the brightness value after a set period It is able to set the brightness of the luminaries the duration of the light ON the time to dim down to 20 separately In this function it uses 1 data bit control the targets directly by setting a permanent fixed value to the output of the staircase luminaries The steps of staircase lighting control the staircase luminaries will be switched on for a certain time this time can be set if the controlled target receives the message of 1 these luminaries will be switched on again when receiving an
2. 1 12 13 14 15 Dim UP Jnehanger Iit oE5 128 64 32 16 8 4 stop dimming Absolute dimming 8 data bits control itis able to dim to the needed brightness value by changing the brightness parameters The setting of the parameters is similar as relative dimming with the brightness value range one low threshold value and one high threshold value And itis not allowed to change the brightness value beyond the set range the max range is from 0 to 255 This function offers the possibility to dim UP or DOWN to 0 gradually to the target value by setting the delay time or the default time The high and low threshold value limits the total output of the dimmer any brightness value beyond the range is not valid When the output is 0 itis able to set switching off the luminaries or remaining to a lower brightness value and also in this status it is optional to switch on the luminaries by receiving the message absolute dimming Status Report 1 data bit the dimmer offers the possibility whether sending the latest brightness value report of the controlled target and the changed report of the switch status to the BUS Scene 8 data bits control the dimmer offers 15 1 15 scenes for selection It is possible to set ONE brightness value and the gradual change time of ON for each scene After setting it is easy to call any favorite scene 1 in the highest bit of the scene command it means saving command to save the current brightness value to
3. KNX LED Controller 4CH 5A SR KNX9512FA FE CE ARIS ww 1 09001 2008 The dimmer with LED constant voltage drive can drive LED directly has four channels each channel is independent The output can connect with some big power dimmable LED lights These LEDs can be switched dimmed recall scene or other operations via the bus The devices adopt PUSH terminals to achieve electrical connection the connection to the EIB KNX bus is established via a bus connecting terminal The input need connect a 12V 36V DC operation voltage The following list provides a functional overview yw Switching the LED light ywRelative dimming yAbsolute dimming yStatus report error report yw Setting 15 scenes yw Staircase lighting function yBus recovery or reset function yvPreset value and modify preset value functions ySwitch relative dimming via manual buttons The above function of parameters to configure and use are described in the chapter 5 The device has own database file vd4 SR KNX9512FA 5A 4CH There is added a manual operation function in the normal dimming mode itis invalid in the staircase lighting mode Switch via a short operation of manual buttons relative dimming via a long operation and in the case of the bus voltage fail the manual operation is invalid Technical data Bus Operating voltage 21 30V DC via the KNX EIB bus Input voltage 12 36V DC 4 channels Rated current 5Ax4CH Load voltage 12 36V DC consta
4. ensure it is mounted in a water proof enclosure 3 Always be sure to mount this unit in an area with proper ventilation to avoid overheating 4 Please check if the output voltage of any LED power supplies used comply with the working voltage of the product 5 Never connect any cables while power is on and always assure correct connections to avoid short circuits before switching on 6 Please ensure that the cable is secured tightly in the connector 7 For update information please consult your supplier Warranty Agreement 1 We provide lifelong technical assistance with this product 5 year warranty We print date on every products for example 1125 means year 2011 week 25 The warranty is for free repair or replacement and covers manufacturing faults only For faults beyond the 3 year warranty we reserve the right to charge for time and parts 2 Limited Warrenty Any defects caused by wrong operation Any damages caused by unauthorized removal maintenance modifying incorrect connection and replacement of chips Any damages due to transportation vibration etc after purchase Any damages caused by earthquake fire lightning pollution and abnormal voltage Any damages caused by negligence inappropriate storing at high temperatures and humidity or near harmful chemicals Product has been updated 3 Repair or replacement as provided under this warranty is the exclusive remedy to the customer
5. fferent parameters to every output channel and control various targets by modifying the setup of the internal parameters Switch The output can be switched ON or OFF by 1 bit data It is able to set the brightness value as the last oneora defined one 1 100 when switching on the luminaries It is able to set a delay time changing time to dim UP the luminaries or dim UP gradually in the default period When receiving the OFF message the dimmer will be switched off immediately or dim DOWN gradually after a delay time changing time or in the default changing period Relative dimming 4 data bits control the relative dimming command means it is possible to dim UP or DOWN to the needed brightness value during the set brightness threshold range It is only valid to dim UP when the brightness value is smaller than the low threshold value and dim DOWN when the brightness value is greater than the high threshold value It is also able to set whether to switch on the luminaries by the message dim UP to a certain value when the output is 0 by this function The relative dimming is used to control the relative changes of the brightness by 4 data bits the lowest 3 bits are controlling bit and the highest bit is 1 means dim UP 0 means dim DOWN Explanation of setting relative dimming 1 7 dim DOWN 0 8 remain unchanged stop dimming 9 15 dim UP Parameter 0 1 2 3 4 5 6 T Dim DOWN o 255 128 64 32 16 8 4 Parameter 8 9 10 1
6. nt voltage Safety Short circuit over voltage and over temperature protection EIB KNX EIB bus connection terminal Inputs outputs Using screwless connection terminal Button and red LED Green LED flashing For assigning the physical address Indicate the application layer running normally Indicate output status per channel LED on mean the a PS tor Cue channel has output LED off mean the channel has not output M butt Switch via a short operation anua OUEONS relative dimming via a long operation OT LED Indicate over temperature gt 70 C OV LED IP 20 EN 60 529 Indicate over voltage gt 40V DC Operation 5 C 45 C Storage 25 6 551 Transport 25 C2470 C Humidity lt 93 except dewing snd XNA SIGNAL OUTPUT o lo gt E 156 0 166 0 23 0 e a Power Supply A S 12 36VDC B SS o E 3 aM SR KNX9512FA 3_ Oot Qov KNX LED Controller 8 Eo kp 2 et Bb RGB W LED strip OD JO Om gt J a Introduction Itis able to set di
7. other message 1 during this period The luminaries will be switched off when they are dimmed down to 20 of the brightness value the dim down time can be set after this period or switch off the luminaries by sending message 0 to the controlled target The luminaries will be off after dimming down to 20 when receiving the message 0 the same dimming down time as above When enabling the function On reception switch OBJ 0 switch off itis able to use the function switch off to turn off the output in the status of permanent on or change the status from switch on to permanent on message 1 means ON 0 means OFF Reset When the BUS is power off all the outputs are switched off the current brightness value will be saved to the memory of the dimmer When the BUS voltage is recovered the brightness status may be the last brightness value or the preset brightness value When the BUS is power off it may have the following situation occurring In the normal mode 2 optional behaviors after the BUS voltage recovery are the last brightness value before power off or the set value In the staircase lighting mode the behavior after the BUS voltage recovery is ON or OFF No output when it is OFF start the behavior switch 1 when itis ON Safety amp Warnings 1 The product shall be installed and serviced by a qualified person 2 1P20 Please avoid the sun and rain When installed outdoors please