Home

PTZ Dome Controller (PTC-01) MANUAL - Provision-ISR

image

Contents

1. PTZ Dome Controller PTC 01 MANUAL English Spanish www provision isr com www provision isr com English Manual Manual en Espa ol WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN Note Only professional technicians is allowed to open the front or back cover of this camera ADVERTENCIA PELIGRO DE CHOQUES NO ABRIR NotA Solo t cnicos profesionales pueden abrir las cubiertas frontal o posterior de esta camara Note In order to avoid electrical shock or fire please use proper power according to the manual Nota Para prevenci n de choques electricos o fuego por favor use la corriente apropiada acorde con el manual Content Precautions Connecting the RS 485 to the camera Remote Control Function List Protocol and Baud rate To set up protocol and baud rate Camera ID Selecting camera Pan tilt speed Presets Home Point Line Scan To delete a preset or a home point or left right limit PATTERN Setting up a PATTERN Dwell Time For setting up the same time to all presets COON NN OOD BW PY 10 11 12 For setting up different time to each preset 13 Resetting all to factory default WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN Note Only professional technicians is allowed to open the front or back cover of this camera 14 Note In order to avoid electrical shock or fire please use proper power according to the manual Precautions 1 In case of smoke or stra
2. e point from any position she is in To set a home point Move the camera to desired location Press and hold PRESET button on the remote control When the display shows SET press HOME Line Scan You can set 2 points for the camera to perform a scan between them These two points are A and B on the remote control When pressing A on the remote display shows LF A When pressing B on the remote display shows LF B To set the left right limits Set the camera to the desired location Press and hold PRESET button for 3 seconds until display shows SET Then press A for settings first limit Move the camera to the other location you want to set as second limit and repeat the last 2 lines using B button instead of A To start line scan Press AUTO button on the remote control the camera will move between the 2 points A and B back and forward To stop the line scan press lt P A To delete a preset or a home point or left right limit You can delete presets or home point using the DELETE button on the remote control When pressing and holding DELETE on the remote control display shows Cir Clr Clear Press and hold DELETE button on the remote control When display shows Clr inserts number of preset that you want to delete or press HOME for deleting the home point you can also delete A B points If the preset number is more then 9 press the button And
3. ement speed as our IR remote control unit S1 8 slow S2 40 3 51 Protocol Pelco D Baud Rate 2400 S4 63 fast e FOCUS focus far If you press DISP button on the remote control display shows U008 or U010 FOCUS focus near Its means that software version is 8 or 18 e OPEN open iris If you press DISP button again display shows d 24 E cl iris CLOSE close iris D Refers to the protocol Pelco D e ZOOM Zoom In 24 Refers to baud rate 2400 e ZOOM Zoom Out PATTERN Start Stop pattern learn To set up protocol and baud rate Press the SETUP button on the remote control Red button RUN run pattern Display shows d 24 DISP Display software version To change baud rate use or 1200 2400 4800 9600 To change protocol use A or Y P PELCO P D PELCO D Press the ENTER button to save configurations e SETUP Set protocol and baud rate F1 F4 User define keys You can set different baud rate and protocol for each camera address For example You can set address 1 with Pelco D and baud rate 2400 Then choose address 2 and set it as Pelco P and baud rate 9600 Camera ID Selecting camera When powered on the display will mark the camera s ID A001 Example A001 A Represents the cameras ID address means it shows you that current camera being controlled is 001 To change ca
4. er e Up Down Left Right Control the pan and 2 Connect the 12VDC power supplier to the PTZ Dome Controller tilt of camera e Enter Stop current movement and a confirmation key after a command e Keys number 0 9 For inputting desired number when needed C Clear backspace when needed to correct last number input e stats 10 mode or go back to normal mode in normal mode you can only input number between 0 9 In 10 mode you can input numbers between 0 255 e ESC at any time press this to go back to address input mode 3 Connect camera to the electricity with the attached power supplier 4 Connect a BNC Rj 59 to the camera from the device your aL CAM Change camera address using DVR or any other recording system SHOT Go to preset button e HOME A B Shortcut for presets e P1 P8 Shortcuts for presets e PRESET Set preset mode Protocol and Baud rate y e DELETE To clear a preset point press You can check current baud rate and protocol or change them ahdhaldsseconds You can choose between Pelco D or Pelco P protocol and select between AUTO start auto cruise mode baud rate 1200 2400 4800 9600 SPEED Set speed of camera s This 2 parameters needs to be set like the camera s baud rate and au protocol check manufacture s user manual movement Our Mini PTZ camera default baud rate and protocol are the same e S1 S4 Shortcut for mov
5. et number 245 Press Preset button for 3 seconds to set preset number between 224 to 239 each preset represents holding time as described beneath To start the pattern press RUN on the remote control To stop the pattern press RUN again preset 224 refers to 2 seconds Note After pressing RUN camera will only move between the preset 225 refers to 4 seconds selected presets for the pattern preset 226 refers to 6 seconds preset 227 refers to 8 seconds preset 228 refers to 16 seconds Dwell Time preset 229 refers to 24 seconds preset 230 refers to 32 seconds In a pattern after setting all desired presets you can change the preset 231 refers to 48 seconds holding time between preset to preset preset 232 refers to 64 seconds Dwell time the time spaces between preset to preset The time the preset 233 refers to 80 seconds camera will stay on the preset before moving to the next one preset 234 refers to 96 seconds You can set a different time between each preset or the same time for all presets preset 235 refers to preset 236 refers to 112 seconds 128 seconds 176 seconds 208 seconds 255 seconds preset 237 refers to preset 238 refers to preset 239 refers to After selecting dwell time you will need to call the presets you want to set up with the dwell time To call a preset press on SHOT button and then the desired presets you want to configure with this dwell time Press preset button for 3 seconds
6. mera press CAM on the remote If the camera number is higher than 9 press the button And write the camera number Example CAM 9 0 ENTER To select camera number 90 Pan tilt speed You can control the speed of pan tilt movement When pressing SPEED on the remote the display shows S 63 S Speed 63 speed value you can change the value between 1 to 63 when 63 is the fastest To change the speed Press SPEED button and then a number between 1 to 63 When using a value higher then 9 press the button and write the camera number Press ENTER to confirm Presets To set a preset Press and hold PRESET button for 3 second or until display shows SET Enter a number between 1 9 if you want to use higher number then 9 Press the button after pressing PRESET After typing a number press ENTER to confirm Example PRESET 1 5 ENTER To set preset 15 To switch between presets press SHOT Then press the desired preset number To move to the preset you programmed Press SHOT on the remote and then the desired preset number If you want to use higher number then 9 Press the button after pressing SHOT Example To call preset 15 SHOT 1 5 Home Point When pressing HOME on the remote control the display shows HOME You can set a home point preset so that when you press HOME on the remote control the camera will move to your pre selected hom
7. nge smell originating from the camera immediately disconnect the power and consult your vendor 2 If the camera seems to be malfunctioning disconnect it and consult your vendor 3 Keep unit away from sharp or flammable objects 4 Keep unit away from high moisture or water 5 Do not drop the unit or subject it to strong shock or vibration 6 Do not install this unit close to magnetic fields the magnetic fields may damage the products performance 7 Do not install the unit where there is greasy smoke or steam where the humidity may get too high or where there is a lot of dust 8 Do not install close to heat sources eg spotlights stoves direct sunlight etc as this could damage the product For the same reason refrain from installing close to the ceiling or in a kitchen ora boiler room because the high temperature may damage the product 9 To clean the product from dust or stains use a dry soft cloth then a damp soft cloth then immediately dry with a dry cloth 10 do not use benzene thinner or other chemical products as the cabinet may be damaged Before using a chemical cloth make sure to read all accompanying instructions Make sure that no plastic or rubber material makes contact with the cabinet for a long period of time as this may cause peeling of the paint Connecting the RS 485 to the camera Remote Control Function List 1 Connect the 2 cables of the camera to the B and A of the z RS485 on the PTZ Dome Controll
8. t are programmed Press Preset button for 3 seconds to set preset number 243 to end Cruise settings 2 seconds 4 seconds 6 seconds 8 seconds 16 seconds 24 seconds 32 seconds 48 seconds 64 seconds 80 seconds 96 seconds 112 seconds 128 seconds 176 seconds 208 seconds 255 seconds e In cases of more presets then showed continue to set up all presets and only in the end set preset 243 to end cruise setup Resetting all to factory default Set preset 240
9. to set preset number 243 IN lt gt Example to set dwell time for presets 1 2 3 4 for 6 seconds Preset 3 sec 242 Preset 3 sec 245 Preset 3 sec 226 SHOT 1 SHOT 2 SHOT 3 SHOT 4 __ _ _ _ en For setting up different time to each preset Example to set dwell time for preset 1 8 seconds for preset 5 4 seconds for Preset 2 2 seconds Preset 3 sec 242 Preset 3 sec 245 Preset 3 sec 227 SHOT 1 Preset 3 sec 245 Preset 3 sec 225 SHOT 5 Preset 3 sec 245 Preset 3 sec 224 SHOT 2 Press Preset button for 3 seconds to set preset number 242 Press Preset button for 3 seconds to set preset number 245 Press Preset button for 3 seconds to set preset number between 224 to 239 each preset represents holding time as described beneath Now call preset 1 to set the dwell time for preset 1 as selected preset 224 refers to preset 225 refers to preset 226 refers to preset 227 refers to preset 228 refers to preset 229 refers to preset 230 refers to preset 231 refers to preset 232 refers to preset 233 refers to preset 234 refers to preset 235 refers to preset 236 refers to preset 237 refers to preset 238 refers to preset 239 refers to Set preset number 245 Set any preset between224 to 239 Call preset 2 The last 3 steps are repeating themselves until all desired prese
10. write the preset number Example DELETE 2 5 To delete preset 25 PATTERN You can set up a pattern from the selected presets and in the order you wish You can set up to 16 presets in the pattern You can also press RUN without selecting a certain pattern that will start a pattern between all presets from 1 to 16 The default time between preset to preset Including the camera s movement until the preset is 8 seconds The speed of camera movement and the stop time dwell time between preset to preset are adjustable Preset 4 Preset Preset 8 6 Setting up a PATTERN When pressing PATTERN for 3 seconds on the remote control Display shows PSTA That means that Pattern track setup mode is on At this mode input the presets you want to include in the pattern the order of inputting the presets is the order which the camera will move between them Input the presets by pressing PRESET button and then the preset number After inputting all presets Press PATTERN button again for 3 seconds Display shows PSTO means that pattern track setup mode is off Example To set up a pattern that will move between presets 1 5 3 in a loop PATTERN 3sec PRESET 1 PRESET 5 PRESET 3 PATTERN 3sec For setting up the same time to all presets Press Preset button for 3 seconds to set preset number 242 Press Preset button for 3 seconds to set pres

Download Pdf Manuals

image

Related Search

Related Contents

Arkon IPHONE A1241 User's Manual  T50 user manual(V1.2) Subject to change without notice  Emtec Secure Digital Mini Card 128MB  燃焼排ガス分析 / CO 測定器  Samsung SGH-E950 Lietotāja rokasgrāmata  Makita RBC280 User's Manual  Above®  Card Software User Manual  2014年度 タートルマリン総合カタログ (PDF 15.2MB)  

Copyright © All rights reserved.
Failed to retrieve file