        Polymsg-01 user manual
         Contents
1.            given area by one touch pressing of button    if   PU   is selected  switch over to exposure time by one touch pressing of button       and set the required time by button or_button   then switch over to  1    pause time by one touch pressing of button    and set the required time by but        ton or button B  Then complete the editing of parameters in the given area       by pressing button  Note  magnetic field parameters set in the first and second areas are common for  all emitters  including addition one      Editing in the third area    switch over to third area of parameters  characteristics by one touch pressing of        button  the pictogram of pulsed magnetic field type should blink at that    wa Set the required type of magnetic field by one touch pressing or holding of button      Or    if itis necessary to change the direction of magnetic field pulses traveling switch    over to required indicator of activated emitter by one touch pressing of button       and set the required direction by button   the change of the direction is    possible only when emitter is activated        complete the editing of parameters in the given area by pressing button Ok f    Editing in the fourth area    switch over to the fourth area of parameters by one touch pressing of button     the pictogram of pulsed magnetic field type should blink at that      set the required magnetic field type by one touch pressing and holding of button       Operating manual Page 18    POLY
2.        Fig  10    In the second area there are      Indicator of the presence of additional emitter and its number  pos  6       Exposure mode  continuous or pulsating  interrupted   pos  5     In the third and fourth areas there are      Pictogram of pulsed magnetic field scan type and kind for the first   second emit   ters pair  pos  7       The indicators of the activated emitters combined with the pointer of pulsed mag   netic field traveling direction  pos  8      Initial setting  The following values of parameters and modes are set  on default  on the liquid   crystal display after power supply with switch  POWER  and activation of required  emitters by the proper buttons  fig  11      In the first area there are      The manner of parameters   M    manual  setting     Exposure time     5 minutes      Indication on the emitter surface     25 mTI      Magnetic field pulses repetition rate     1 pul s        Operating manual Page 15    POLYMAG 01       Fig  11    In the second area there are      Indicator of additional emitter in the form of transparent  sun  in case of additional  emitter absence and as dark  sun  and number   if it is connected      Exposure mode        CN        continuous    In the third and fourth areas there are      Pictograms of pulsed magnetic field type for the first second emitters pair     travel   ing horizontal     The indicators of the activated emitters in the form of transparent square if the  emitter is not activated  and in the form o
3.    From the part of hippocampus there is noted synchronization of secretory cells  function  activation of synthesis and getting neurosecretory substance out of its nu   Cleus as a result of the magnetic field exposure  At the same time there is increase of  hypophysis portions functional activity  However under the long and great  more than  70 mTI  magnetic field exposure there can be depression of neurosecretory function  and development of productive dystrophic processes in CNS  central nervous system   cells    So as result of the action of low intensity magnetic field we have evident positive  effect  reduction of cerebral vessels tone  improvement of brain blood supply  activa   tion of nitrogen and carbohydrate   phosphoric metabolism intensifying brain stability  to hypoxia    Under the influence of magnetic field on cervical sympathetic nodes  suboccipital  or transcerebral area  there is improvement of cerebral blood flow  the data of rhe   ovasography      Under the influence of magnetic field on suboccipital area  patients with a circula   tory insufficiency invertebrobasilar system  there is evident improvement of cerebral  hemodynamics    Thus  with the help of alternating magnetic field there may be correction of cerebral  hemodynamics abnormality with various pathological states    i There is noted the reaction of peripheric nervous system to action of a magnetic  ield       decrease of peripheric receptors pain sensitivity threshold resulting in anesthe   ti
4.   aara and tubular affections caused by medicaments and heavy  meta      Renal and ureteral calculus       Calculuses of urinary ways lower parts       Cystitis       Urethritis and urethral syndrome       Hyperplasia of prostate gland       Prostate gland inflammatory diseases       Benign dysplasia of lactiferous gland       Salpingitis and oophoritis       Uterusinflammatory diseases  except for uterus cervix       Uterus cervix inflammatory diseases       Other inflammatory diseases of female pelvis organs   PREGNANCY  CHILDBIRTH  PUERPERAL PERIOD       Children bearing related non purulent mastitis       Other changes of lactiferous gland and lactation disturbances related with chil   dren bearing   INDIVIDUAL STATES ARISING IN PERINATAL PERIOD       Birth trauma of peripheric nervous system   TRAUMAS  POISONINGS AND SOME OTHER CONSEQUENCES OF EXTER   NAL INFLUENCE       Brain concussion    Operating manual Page 4    POLYMAG 01        Neck injury       Backbone cervical part fracture       Dislocation  a stretch and injury of capsular ligamentous apparatus at the neck  level       Both nerves and a spinal cord trauma at neck level     Chest traumas      Rib  ribs   breast bones and backbone thoracal part fracture     Dislocation  stretch  both chest joints and capsular ligamentous apparatus injury       Thorax nerves and spinal cord trauma       Both stomach  back lower part  backbone lumbar part and pelvis traumas       Fracture both of backbone lumbosacral part and pel
5. 1 6  day after magnetic field single action  and after the taken procedure course   30 45  days  this stipulates necessity to make break between repeated magneto therapy  courses for chronic diseases treatment    Influence of magnetic field on background of organ or system increased function  results in its decrease  and application of magnetic field in the state of function de   pression is accompanied with its elevation     Operating manual Page 5    POLYMAG 01    Organism organs and systems have different reaction upon the action of magnetic  field  Organism response reaction selectivity depends on tissue electric and magnetic  properties  their difference in microcirculation  metabolism intensity    According to organism systems degree of sensitivity to a magnetic field  nervous  system takes the first place then come endocrine systems  sense organs  cardiovas   cular  muscular  digestive  secretory  respiratory and skeletal  osteal  systems    At influence by low intensity magnetic fields on nervous system central parts and  reflex zones there are the changes of conditioned reflex function  physiological and  biological processes  The most evident reaction of the organism from central nervous  system reveals itself in hypothalamus  then comes cerebral brain cortex  hippocam   pus  reticular formation of midbrain  As a result there is inhibitory processes resulting  in sedative and healthiness effect of magnetic field to sleep and emotioanal excite   ment of the organism 
6. 14    Additional emitter 900 120 20 1 0  Working area 580 93 14    Power cable 1800        Emitters power cable 2500                               2 12 Mean lifetime  min    5 years   2 13 External surfaces of the device component parts are stable to disinfection by  chemical methods  396 solution of hydrogen peroxide or 5 solution of chloramine     3  PACKAGE SET    POLYMAG 01   magnetotherapeutic device including                                            1   Control block unit 1 pc   2   Emitter 4 pcs   3   Additional emitter 1 pc   4   Magnetic field indicator 1 pc   5   Operating manual 1 pc   6   Methodical recommendations for   POLYMAG 01   magnetotherapeutic device appli  1 pc   cation in physio therapeutic practice   7   Accessories complete set    stand rack 1 pc     frame 1 pc       Operating manual Page 9    POLYMAG 01    4  ARRANGEMENT AND OPERATION  Device appearance  fig  1    Control board   of control block unit      Control block unit Mains switch         Fix holder  for    emitters  arrangement   Handle  Emitters  Stand rack           i   Frame       d Fig  1    Emitter appearance  fig  2    Flexible emitting      strip lines  Pulses generation    unit    N o2 Coil inductor    Fig  2    Operating manual Page 10       POLYMAG 01    Marking  There are following marking on the device      Attention  apply to operating documents      e    B type working part      Sign indicating the belonging of the device to B type according to electric  shock protection  IEC 
7. 601 1 88      Device operation   The device generates pulsed magnetic field of two types      traveling  and    fixed      In basic emitters   traveling   magnetic field has three type scans and two directions of  these fild scan         traveling vertical     fig  3      simultaneous actuation of all inductor in one line   coils  assembly exposure unit  with the following one way actuation of next line all induc   tors according to cyclic mode law  Cycle for the given scan type is four    steps   ac   tuation of inductor lines  according to the number of lines in emitter         000000        traveling horizontal    fig  4    simultaneous actuation of the one type inductors in  all lines with the following one way actuation of next inductors under the cyclic mode  law  cycle for the given scan type is six   steps   actuation of the adjacent inductors   according to the number of inductors in lines                                             Operating manual Page 11    POLYMAG 01       traveling diagonal   fig  5    simultaneous actuation of 4 inductors in all lines with  diagonal location with the following one way actuation of the adjacent inductors ac   cording to cycle mode law  cycle for the given scan type is six   steps   actuation of  adjacent inductors  according to the number of inductors in line                  L              Fig  5    In the additional emitter there is generated either of   traveling   field  fig 6      actua   tion of the inductors according to 
8. F  if editing of other pa     rameters in the selected area is not required by transition to the other editing parame      PO CS    ters with T l buttons     Note  Fixation of the edited parameter characteristic takes place automatically  if  there is no pressure on control buttons during 12 15 sec        Editing in the first area      switch over  move  to first area by one touch pressing of a button  sign   M    should start blinking           switch over to time value editing by one touch pressing of  gt  button     __  set the required value by one touch pressing or holding button or button         switch over to editing of induction value by one touch pressing of button    _  set the required value by one touch pressing or holding button Wi or button       4     switch over to editing of frequency value by one touch pressing of button      or button    set the required value by one touch pressing or holding button       Note   1  Editing of parameters   characteristics inside area can be carried out in a ran   dom order        2  You can complete process of editing at any moment by pressing button    Operating manual Page 17    POLYMAG 01  Editing of the second area    switch over to the second parameter area by one touch pressing of button GS     sign   CN    continuous field  at that should blink      set one of exposure modes    CN      PU   by one touch pressing of button    or button    if   CN   exposure mode is selected   complete the editing of parameters in the 
9. MAG 01    if itis necessary to change direction of magnetic field pulses traveling  switch    and set the required direction by button  sible only when emitter is activated              one the editing of parameters in the given area by pressing button   ote    1  The choice of area of parameters characteristics for editing may be carried out in  random order    2  The change of exposure parameters characteristics is possible only if there is no  magneto therapeutic influence    3  In order to set the    fixed   magnetic field for additional emitter  it is necessary to  set   fixed   magnetic field for the first pair of basic emitters  they can not be neces   sarily used   There are generation of unidirectional   traveling field   in the additional  emitter for all other types of magnetic field      Making of exposure program   In the device there is provided for the ability to store the set exposure parameters  in the form of programs P1   P8  which are stored in non volatile memory of the de   vice and then can be easily recalled to speed up parameters setting      switch over to the first area of parameters by one touch pressing of button     sign  P  should start blinking with that       select the number of program where magnetic field parameters characteristics       will be stored by one touch pressing of button V    set required parameters characteristics with ihe help of control units according to  procedure for manual setting     Recall of exposure programs       sw
10. POLYMAG 01    THE TABLE OF CONTENTS  T INTENDED USE  issnin iein esini ii arrendersi a tuu dedos 2  1 1 General information                         esses 2  1 2 Indications for application               cccccceceeccceeceeeeeeeeeeeeeeeeeees 2  1 3 Contra indications   aso dioere Re avs ree eda EUR events 5  1 4 Mechanisms of physical and therapeutic action of  magnetic fields    cote a ate ade a aas 5  2  SPECIFICATION ere denori erasa erorri t Pens K aar reta iini nao re anna  8  JS PACKAGE SE Ponari a aaa CH es amine HR eR d 9  4  ARRANGEMENT AND OPERATION                 esses 10  5  SECURITY MEASURES 3  10 Gran fidet tice ee oai yo a 21  6  PREPERATION OF THE DEVICE TO OPERATION                 22  7  THE ORDER OF DEVICE OPERATION                     eeeeeeeee 22  8  MAINTENANCE SERVICE                cccccccescsseeeeeeeeeeeesesseneeeeeeees 24  9  ROUTINE MAINTNAN GE      iicet inito eet s co dace 25  10  STORAGE and TRANSPORTATION                  sess 26  TTAGOCEPTANOGCEGERTIFICATE  i oi ae exo Eee de pn 26  12  MANUFACTURER WARRANTY             seeseeeeeereneennnne 27    Operating manual Page 1    POLYMAG 01    Dear buyer    You have got  Polymag 01  magneto therapeutic device  hereinafter  the device   intended to be used for therapy of a wide spectrum of diseases by low frequency   low intensity magnetic field  The device pertains to products of medical technique and  is included in the nomenclature of physiotherapeutic devices allowed for application in  medical prac
11. SORDER   e Somatophormic dysfunction of vegetative nervous system   e Neurocirculatory dystonia on hypertonic type   ILLNESSES OF NERVOUS SYSTEM   e Disseminated sclerosis   e Remittent sclerosis   e Secondaty   progressive sclerosis   e Primarily   progressive sclerosis   e Progressive   e Migraine   e Transient transitional cerebral ischemic attacks and congenerous symptoms   e Affection of separate nerves  nervous roots and plexuses    e Mononeuropathies of the top and bottom extremity     Tunnel neuropathies       e Causalgia   e Alcoholic polyneuropathy   e Diabetic polyneuropathy   e Children s cerebral paralysis  spastic  hyperkinetic forms    e Hemiplegia    Operating manual Page 2    POLYMAG 01    ILLNESSES OF CIRCULATORY SYSTEM   e Idiopathic hypertension of I II degree    e Stenocardia   e Heart chronic ischemic illness   e Insult   hemorrhage or an infarct    e The other cerebrovascular illnesses   e Aftereffects of cerebrovascular illnesses   e Atherosclerosis   Including    e Arteriolosclerosis   e Arteriosclerosis   e Degeneration      arterial     arteriovascular     vascular   e senile deforming or an obliterating endarteritis       arteritis     endarteritis   e Phlebitis  thrombophlebitis   e Lower extremities varix dilatation and itsaftereffects   e Nonspecific lymphadenitis   Other infectious diseases of lymphatic vessels and lymphatic nodes  including  lymphostasis in the postoperative period     ILLNESSES OF RESPIRATORY ORGANS   e Pneumonias   e Communi
12. agnetotherapy renders disagregative and hypo   cagulatory effects  improves microcirculation and regionary blood circulation  favora   bly influences immunoreactive and neurovegetative processes    Magnetic field action  as a rule  does not cause formation of endogenic heat  rise in  temperature and skin irritation     It is marked the good tolerance of magnetotherapy by the weak patients  advanced  age patients  suffering with accompanying diseases of cardiovascular system that al   lows to apply magnetotherapy devices in many cases when influence with other  physical factors is not indicated     2  SPECIFICATION   2 1 The induction amplitude value on surface of emitter  inductors for  traveling   field type is from 2 up to 10 mTI with discreteness 2 mTI and from 10 up to 25 mTI  pu discreteness 5 mTI  and for  fixed  field   from 2 up to 6 mTI with discreteness 2  mTl    For magnetic field induction values from 2 mTI up to 20 mTI an absolute deviation  from the rated value A is in the ranges    0 2 A   0 6  mTI  for induction value 25  mTI  frequency 75 Hz is in the ranges 6 3 mTl    2 2 Magnetic field pulse repetition rate is set as follows      for  traveling  field  induction amplitude from 2 up to 20 mTI   in the range from  1 up to 100 Hz  for induction amplitude 25 mTI  in the range from 1 up to 75 Hz with  discreteness 1 Hz  Relative deviation from the specified value is in the ranges  5 96     for  fixed  field type   in the range from 1 up to 16 Hz with discretenes
13. anty period   12 month from the day of sale    Within the warranty period manufacturer free of charge eliminate the defects or re   place the device or its components parts against the warranty coupon presentation    Guaranty terms    The guarantee is valid only with the presence of the right filled guarantee coupon  with trading organization product serial No  date of sale and seal in it    The guarantee does not cover the following cases      device has marks of non authorized action or there was attempts to repair it at  the unauthorized service center      there is non authorized changes of device design or circuit      device has mechanical damages      device has the damages as a result of ingress of foreign objects  substances and  liquids in it      device has the damages caused by power supply mains parameters unconform   ity to requirements of State standards    Electric circuits  the description and other design specifications are being sent by  the manufacture on demand of the authorized service centers     In order to make repair the faulty device is to be sent together with operating man   ual and enclosed explanatory note to the address     JSC   Yelatma Instrument     Making Enterprise    25  Yanina st 391351   Yelatma  Kasimov district  Ryazan region    Additional information for operation and repair you can get by the phone   4912  24 01 39  44 06 61    Operating manual Page 27    POLYMAG 01    FOR NOTES    Operating manual Page 28    
14. brain  heart  bloods  liver  muscles   spleen   lien  and its increase in an osteal tissue  This Fe redistribution is connected  to change of hemopoiesis organs state      Operating manual Page 7    POLYMAG 01    Besides there is increase of CU content in in heart muscle  lien  spermaries that  stimulates adaptive compensatory processes of an organism  Co content in all organs  reduces and there is its redistribution between blood  separate organs and tissues   Under influence of a magnetic field there is increase of Mg biological activity  It results  in decrease of the development of pathological processes in a liver  heart  muscles    It is noted  that magnetic fields of low induction stimulate processes of tissue respi   ration  changing a balance of free and phosphorylate oxidations in respiratory chain   Increase of nucleic acids and albumen synthesis exchange resulting in acceleration of  trophicoregenerative processes    Tipical manifestation of action of magnetic field on an organism is activation of  processes of carbohydrates and lipids metabolism  The last is shown in the increase  of nonesterificated fat acids and phospholipids in blood and internal organs  decrease  of cholesterin in blood    Thus  the short time action by magnetic field on human organs and systems has a  number of beneficial effects    e analgesic     e anti inflammatory    e anti edematous     e trophico regenerative     e hypotensive    e sedative actions    With influence on large vessels  m
15. cessary to apply to service  Office           if one or several emmiters are out of order  the operation with the serviceable  ones is allowed with disconnected from the device fault emitters     Operating manual    Page 25       POLYMAG 01    10  STORAGE AND TRANSPORTATION OF THE DEVICE  The device withstands storage in not heated warehouses with air temperature from   50   C up to  40   C  air relative humidity  max  98 96   The device can be transported by all types of covered transport facilities according  to the rules of cargo transportation for concrete type of transport facility at air tempera   ture from  50   C up to  50   C and relative humidity  max  98 96     11  ACCEPTANCE CERTIFICATE    POLYMAG 01   magneto therapeutic device works number is  manufactured and accepted in compliance with technical specifications  TWKC 941519 101 TY and is recognised as ready for operation     Output date Stamp           signature of person responsible for acceptance     POLYMAG 01   magneto therapeutic device is packed according to the require   ments stipulated by the design documentation     Date of packing  Packing is done by Stamp          Operating manual Page 26    POLYMAG 01    12  MANUFACTURER S WARRANTY   The manufacturer guarantees the quality conformance of the device to require   ments of operating manual section   Technical specifications   should the customer  strictly observes terms and rules of storage  transportation and maintenance    Device operation life warr
16. cycle mode law in one way direction  line cycle is six    steps actuation of adjacent inductors  according to the number of inductors in the  line   or   fixed field    fig 7     000008     Fixed field   fig  7      simultaneous actuation of all emitters inductors                   Operating manual Page 12    POLYMAG 01    Function of control and indication units  Emitters control unit  There are control and indication units on each emitter and control board of device  control block unit   On the emitters  fig 8  there are     Four inductors  pos 1  signalling of magnetic field availability in each of the lines     Emitter activation button  pos 2      Activation state indicator  pos  3  signaling of emitter operationability        Indicator  signaling of magnetic field availability in line lights each time within the  process of magneto therapeutic exposure  action  when there is magnetic field in any  of the inductors    The activation button  without fixation  allows to actuate the emitter by its one   touch pressing and to prepare it for the process of magneto therapeutic influence or to  dis actuate it by its repeated pressing    Lighting indicator proves the fact of emitter activation    ote    1  Emitters can be activated   dis activated at any time after device actuation    2  Activation state indicator after pressing of activation button should light not later  than after two seconds     Device control board control organs  There are following control and indication 
17. ease of vessels walls tonus  the change of elastic  properties and bioelectric resistance of blood vessels walls    Change of hemodynamic  including hypotensive effect  is connected with the de   velopment of bradycardia effect and decrease of myocardium contractive functions   This property founds its application for idiopathic hypertensia treatment and also is  used to reduce heart burden with stenocardia    Magnetic field makes the influence for the development of changes in various tis   sues microcirculatory canal    At the beginning of the process of magnetic field influence there is short time  5 15  minutes  slowing down of capillary blood flow which lately changes for microcirculation  intensification    During the time and upon the termination of magnetotherapy course there are ac   celeration of capillary blood flow  improvement of vascular wall contractive abilities and  increase of vessel blood accumulation  Enlagement of microcirculatory canal function   ing components lumen promotes the opening of previous capillaries  anastomoses  and shunts    Under the influence of magnetic fields there is increase of vascular and epithelial  permeability  direct result of which is accelaration of both edema and taken medicinal  substances resorption    Due to this effect  magnetotherapy has found its wide application to liquidate  edemas of various aetiology  traumatic  inflammatory     Under the influence of permanent alternating treveling magnetic field there is  incease 
18. f black square with an arrow pointing the di   rection of field traveling if itis activated     Editing of basic parameters characteristics with manual manner of setting  Editing basic principle      transition to the required area      transition to the required exposure parameter  characteristic      setting of selected parameters and characteristics      fixation of  parameter  characteristic selected value        hd buttons are used for transition to the required area    Transition to the required area is possible at any period of time  except the moment  when the editing has already been taking place inside some area or magneto   therapeutic exposure is activated    The fact of transition to selected area is signs blinking of      in the first area   manual   M  or programmed manner   P1       P8   of parameters  and characteristics setting      in the second area     exposure modes    CN    continuous mode     or   PU     pul   sating  discontinuous  mode       Operating manual Page 16    POLYMAG 01    in the third and fourth area   pictogram of field type     Transition inside the area to the required parameter and characteristic is carried       out with the buttons S  The change of selected ponds and characteristic is carried out with buttons        iJ   only during the time of blinking   Signs       n       on the button lower  register indicate the direction of edited parameter and characteristic change        Parameter value fixation is carried out with button   O
19. g supply voltage 220V   10       1096  or 230V   10    6   and frequency 50 Hz    The device can be connected to mains with two contact sockets  for example   with the help of an adapter   however in this case under electrostatic discharges there  may malfunctions in its operation  display flash   For the purpose of malfunction elimi   nation you should disconnect the device and then connect it again    e Do not permit 10   side inclination of the device    e When there is necessity in device displacement use only stand rack handle de   signed for this purpose     IT IS PROHIBITED       to lift or carry the basic emitters and additional emitter by power cable       to twist emitters connecting cables        to plug in the device if the plug and the socket are incompatible       to unplug the device pulling the power cable    e to carry  displace  emitters during the process of magneto therapeutic influence    e to place the activated device close less than 0 5 m  to information magnetic car   riers  audio  videodevices and others magneto sensitive devices    ATTENTION    e In order to avoide the fail of the device IT IS PROHIBITED to actuate device if  the position of emitter cables headers  connectors   connected to control block unit  is  not fixated with the help of screws       a IS NOT ALLOWED to operate the device with the air temperature more than   35   C      In order to prevent patient and attendants themselves from trauma you should be  careful at work with emitter
20. itch over to the first area of parameters by one touch pressing of button   sign    P    should start blinking with that            fix the selected exposure program by pressing button is      Program fixation can  be carried out after program sign blinking termination     Operating manual Page 19    POLYMAG 01    The device initially has the set of exposure programs  see table 2                                                                                                                                 Table 2  bod The name of nosology Exposure parameters  Time   min  20  i Cerebral blood flow      i duction mT 10  Frequency pul  s 10  Exposure mode  Continuous CN   Type of pulsed magnetic field Traveling vertical  pa Oblitarati PE Time   min  30  tis  varicose disease   Induction  mTI 20  Frequency pul  s 10  Exposure mode  Continuous  Type of pulsed magnetic field Traveling horizontal     Time   min  20  P3 Hypertonic disease Induction  mtl 2  Frequency pul  s 5  Exposure mode  Continuous  Type of pulsed magnetic field Traveling horizontal      i Time   min  20  aoe  4     Induction  mT 20  Frequency pul  s 10  Exposure mode  Continuous  Type of pulsed magnetic field Traveling horizontal      Time   min  20  P5 Chronic hepatite Induction  mTl 20  Frequency pul  s 8  Exposure mode  Continuous  Type of pulsed magnetic field Traveling horizontal     4 Time   min  20  P6 Chronic pancreatitis Induction  mTI 10  Frequency pul  s 5  Exposure mode  Continuous  Type of pulsed mag
21. netic field Traveling horizontal  P7 Femal itals i Timen min  au  fiamitory dissdsae Induction  mTI 6  Frequency pul  s 16  Exposure mode  Continuous  Type of pulsed magnetic field Fixed  E Time   min  30  P8 Immunogeticisngy Induction  mTI 2  Frequency pul  s 100  Exposure mode  Continuous             Type of pulsed magnetic field       Traveling horizontal       Operating manual    Page 20       POLYMAG 01  Note  the storage of program data is carried out every time by pressing button       or after the termination of editing object blinking      ON OFF activation stopping  of magneto therapeutic exposure    ON OFF magneto therapeutic exposure by one touch pressing of button    Note  exposure activation is possible if at least one emitter is activated or additional  emitter is connected     5  SECURITY MEASURES   e Use the device only after careful reading of operating manual    e Be sure in the absence of cable  mains operated plug  mains cord  emitter and  control block  unit body mechanical damage  It is FORBIDDEN to use the device with  presence of these damages    e Prevent the ingress of moisture inside both emitters and control block unit at their  surfaces treatment with disinfectant solutions  Protect the device against dampness   shaking and shocks    e The device is to be arranged in the places convenient to be connected to the  mains operated socket  excluding power cable tension  You should use only service   able socket with grounding contact with mains workin
22. ng  sound signaling and  appearance of one of the signs  on LCD       NO 1 EMMIT        NO 2 EMMIT          NO 3 EMMIT        NO 4 EMMIT          NO ADD  EMMIT        Bad contact in connector of  one of the emitters with an  appropriate number or  additional emitter    Break in the connecting  cable     Unplug the device  To check  connector fixation  if  necessary  to fixate  connector    To actuate the device    Apply to service office        2  There is formation of warring  sound signaling and  appearance of one of the signs  on LCD         FAULT OF 1 EMMIT            FAULT OF 2 EMMIT            FAULT OF 3 EMMIT            FAULT OF 4 EMMIT            FAULT OF ADD  EMMIT        The fault of one of the  emitters with appropriate  number or additional emitter     Apply to service office        3  There is formation of warring  sound signaling and  appearance of one of the signs  on LCD          NO SAF  CONTR        Fault of device current  overloading protective unit    Apply to service office        4  The absence of magnetic  field in one of or several  emitters    inductors     The break of connecting wire  inside the line  coil inductors  assembly exposure unit     Apply to service office          5  No light indication of  magnetic field availability in one  of the emitter pairs        There is actuation of self   regenerating safety fuse FU1  or FU2        Unplug the device for 2  minutes  plug the device and  actuate exposure mode  If  the fault is repeated  it is  ne
23. of metabolic processes in bone regeneration area  with fracture   at earlier  period there is occurrance of fibrous and osteoblasts in a zone of regeneration  proc   ess of osteal substance formation is going on more intensively     Under the influence with magnetic fields there is the change of rheological proper   ties of blood  Hypocoagulation effect is marked due to    e ctivation of anticoagulative system    e decrease of intravascular parietal thrombosis    e recrease of blood viscosity due to the action of low intensity magnetic fields on  enzymatic processes  electric and magnetic properties of blood elements taking part  in hemocoagulation     The action of a magnetic field renders considerable influence on metabolic proc   esses in organism    Under the action on organism particular systems there is increase both of the  amount of albumens and globulins in blood serum and their concentration in tissues  due to a   and y   globulin fractions resulting in the change of albumen structure    With short term daily action of magnetic fields on an organism there is reduction  of pyruvic and dairy acids content not only in blood  but also in liver and muscles  resulting in incrase of glycogen content in a liver    There is reduction of ions Na content with simultaneous rising of ions K concen   tration in the tissues due to the action of magnetic field   that is the evidence of the  change of cellular membranes permeability     It is marked the reducrion of Fe content in a 
24. organs on the device control board  fig  9    1     liquid crystal display  indicating device exposure parameters    Liquid crystal display is divided into 4 area  fig 9  where the set parameters  char   acteristics are grouped   1    TE       2     button 1      to select the first area of changeable parameters   character   istics    f        moving up inside the selected area        3     button  2      to select the second area of changeable parameters   char     acteristics         reduction of selected parameter     Operating manual Page 13    POLYMAG 01         4     button Wl  3      to select the third area of changeable parameters   charac   teristics             increase of selected parameter     5     button    4      to select the fourth area of changeable parame   ters characteristics         moving downward inside the selected area        6     button   This button serves to fix the selected parameter  to complete  parameters setting  editing       7     indicator indicatina the availability of magneto therapeutic action   MO  8     button      Given button serves for magneto therapeutic influence  on off        Number of parameters characteristics  areas    The first area includes  fig  10       Manner of parameters characteristics setting     manual or programmed  pos  1      Exposure time min  pos  2       Induction value on the emitter surface  mTI  pos  3       Magnetic field pulse repetition rate pulse s  pos  4      Operating manual Page 14    POLYMAG 01
25. ormation device body with hands fingers  and  place them on the patient body        The manner of flexible stripe lines disposition is defined by the procedure for  definite illness treatment        Arrange control board in the position convenient to work with in oder to avoid the  apearance of glare on the display        Connect the device to power supply mains and switch it on by pressing     POWER    switch        Activate required emitters     Note    1  Emitters should be connected to appropriate connectors of control block unit   see the numbers of connectors     2  Emitters connectors should be fixated to control block unit connector with  Screws       Do editing of exposure parameters taking into consideration the following circum   stances      for those cases when thin fabric materials are used to protect patient against  contact to accessible strip lines surfaces the same exposure parameters  specified in  treatment procedures for concrete disease  are being set      Activate magneto therapeutic exposure at the same time there should appear a  sound signal and flash magneto therapeutic exposure indicator on the control board   unit  fig 9  pos  7   and indicators of magnetic field presence     on the emitters  fig  8     s  1    During taken procedure there are indication of set parameters on liquid crystal dis     play and time left up to magneto therapeutic exposure termination in the position   Time  min      Operating manual Page 22    POLYMAG 01    Upon the ex
26. posure time termination  both indicator of magneto therapeutic expo   sure and indicators of magnetic field presence on emitters become dim  on liquid   crystal display there is indication of preset treatment time  the other parameters are  stored as well  sound signal is occurred in order to notify attendants of exposure  mode termination        Disactivate the device by pressing the switch   POWER    unplug the device        Remove the emitters off the patient and place the emitters back to the fix  holder  in reverse order holding pulse generation unit by two hands        Upon the exposure time termination  both indicator of magneto therapeutic expo   sure and indicators of magnetic field presence on indicators light off  on liquid crystal  display there is indicated the preset treatment time and the other parameters  in order  to announce attendants of exposure mode termination there is occur of sound signal    Note  The given operating procedure is not strict and be changed at the user  option  For example  you can first plug the device up  to activate necessary emitters   to set exposure modes and exposure parameters  and then to place emitters on the  patient body     Operating manual Page 23       POLYMAG 01    8  MAINTENANCE SERVICE  The order of maintenance service is given in the table        The name of the work    Periodicity       1  Device preventive inspection  2  Dusting  cleaning  disinfection   3  The check of emitters operation       Not rarer than once th
27. ree months     As required     Not rarer than once a month        e When carrying out preventive inspection you should pay attention to of cables   plug  mains cord  both emitters and control block unit bodys integrity   e The check of emitters operation is to be carried out as follows      connect emitters to the device and arrange them so that to provide access to all    emitters inductors       plug device and actuate it by pressing switch  POWER        activate all emitters       set induction value  25 mTI  pulse repetition rate  75 Hz  the other parameters      on default       activate magneto therapeutic exposure       check the presence of magnetic field in each of 24 inductors of each emitter with    the help of magnetic field indicator     stop magnetic field exposure       disactivate the device by pressing switch   POWER   and unplug the device     Operating manual    Page 24       POLYMAG 01    of warranty period     9  ROUTINE MAINTENANCE  Routine repair of the device is carried out under the contract between medical insti   tution and the manufacturer or its branch office after technical examination of nature  and degree of failure by manufacturer representatives   Upon the repair termination the device is passed on to the user with determination    Typical faults and methods of their elimination       The name of fault  their outward  manifestation and additional  features     Fault probable reason    Method of elimination       1  There is formation of warri
28. s      Emitter should be carried by two hands  clasping the faces of the pulses  formation device body with hands fingers     Operating manual Page 21    POLYMAG 01      For the period of magnetic exposure the ACTIVATED EMITTERS should be  REMOVED from the OPERATOR on distance not less than 0 9 m   Use the disinfected fabric material to protect emitters accessible parts from contact  to the patient     6  PREPERATION OF THE DEVICE TO OPERATION     After device storing into the cold premises with the temperature below 10   C be   fore use let it be warmed up in the premise with the temperature from   10   C to   35    C for 4 hours      If it is required  make the disinfection of the device external surfaces with one of  disinfectant agents listed in    Methodological Guidances on disinfection  pre   sterilization treatment and sterilization of medical products    by twice wiping with cotton  napkin with the interval 10 15 min   Pay attention that the napkin should be wringed  out in order to avoid ingress of solution into device      7  THE ORDER OF DEVICE OPERATION      Place the patient on a couch in position convenient for him for the time of treat   ment period        The device should be put towards the couch in the convenient position both to be  connected to mains and arrangement of flexible emitters for magnetic exposure on the  patient        Take  with care by two hands in order  necessary for exposure emitters out of fix   holder  clasping the faces of the pulses f
29. s 1 Hz   Relative deviation from the specified value is in the ranges   5 96    2 3 Magnetic exposure procedure set time intervals range is from 5 up to 30  mines  setting interval is 5 minutes  Relative deviation from the specified value is in  ranges  5 96    2 4 The device operates in the following regimes   continuous  CF   discontinuous   DF     2 5 In a regime of discontinuous magnetic exposure  the time of magnetic    Operating manual Page 8    POLYMAG 01    exposure Te and time of pause Tp is set in the ranges from 1 up to 60s with  discreteness 1s  Relative deviation from the specified values is in the ranges   5 96    2 6 There is marking of magnetic field polarity   N   the north   S   the south on the  device emitters    2 7 The device provides detection of the basic fault conditions  signalling system  and automatic stopping of the device exposure mode    2 8 Time of device continuous operation   min  8 h  with cyclic operating mode  30  min    magnetic exposure  10 min    break    2 9 The device is in the state of operation being supplied with mains alternating  current  frequency   50 Hz  voltage   220V   10 96   10 96  or 230V    10 96   6 96     2 10 Electric power consumption  210 V A    2 10 Overall dimensions and weight of device component parts are shown in the  table 1                         Table 1  Name of component parts Dimensions   mm  max  Weight  kg   length width height     Device 685 440 1200 40 0  Emitter 1000 400 40 4 0  Working area 580 372 
30. tice    Attention  Before the device application it is necessary to study thoroughly  the enclosed operating manual in order to get the effective treatment    The operating manual is the document identifying basic technical parameters   characteristics of the device guaranteed by manufacturing enterprise  therapeutic indi   cations and treatment procedures with the device     1  INTENDED USE   1 1 General information   1 1 1 The device is intended to be used for therapy with low frequency  low   intensive magnetic field    Device provides generation of continuous and discontinuous pulsed magnetic  fields  traveling  rotating  pulsating  differ in configuration  intensity  direction and  speed of magnetic field traveling in space  The device ability to influence the large  affected areas  extremities  body  increases magneto  therapy efficiency due to the  extensive influence on micro circulation flow     1 2  The device is designed to be operated in normal climatic conditions      air temperature  from  10  C to   35   C      atmosphere pressure 86 6     106 7 KPa  600   800 MM Hg      1 1 3 The device electrical safety  Class I  type B  IEC 601 1 88     1 1 4 According to failure effects the device belongs to Class B     1 2 Indications for application   BLOOD ILLNESSES  ILLNESSES of BLOOD FORMING ORGANS AND SOME  ABNORMALITIES INVOLVING THE IMMUNE MECHANISM       Other immunodeficiencies  Immunodeficiency conditions with radial therapy     MENTAL DISORDERS and BEHAVIORAL DI
31. ty acquired pneumonia   e Acute bronchitis   e Simple and mucopurulent bronchitis   e Unspecified chronic bronchitis   e Asthma   e Bronchoectatic disease   ILLNESSES OF DIGESTIVE APPARATUS   e Stomach ulcer   e Ulcer of duodenal intestine   e Gastritis   e Duodenitis   e Syndrom of irritated intestines without a diarrhea   e Abdominal adhesions   e Alcoholic illness of a liver   e Liver unspecified toxic affection   e Cholecystitis   e Biliary dyskinesia   e Chronic pancreatitis   e Syndrom of operated stomach   e Postcholecystectomy syndrom   e Celiac disease   ILLNESSES OF THE SKIN AND SUBCUTANEOUS FAT   e Atopic dermatitis     Psoriasis    Operating manual Page 3    POLYMAG 01    OSTEOMUSCULAR SYSTEM AND THE CONNECTING TISSUE DISEASES       Gout       Traumatic arthropathy       Polyarthrosis       Coxarthrosic       Gonarthrosis       Arthrosis of the first carpometacarpal joint       Other arthrosis       Joint contracture       Rheumatic polymyalgia       Backbone osteochondrosis       Affection of cervical spine intervertebral disks       Affection of intervertebral disks of other parts       Vertebrobasilar syndrome       Dorsalia       Cervicalgia       Radiculopathy       Lumbago with an ischias    Ischias       Myalgia       Neuralgia and neuritis       Pain in an extremity       Osteoporosis with pathological fracture       Osteoporosis without pathological fracture       Osteomyelitis   GENITOURINARY SYSTEM DISEASES       Chronic tubularinterstitial nephritis   
32. vic bones       Dislocation  stretch and injury both of lumber spine capsular ligamentous appa   ratus and pelvis    Trauma of both nerves and spinal cord lumbar part at stomach level  back  lower part and palvis a basin       Thorax traumas      Fracture of both a rib  ribs   breast bone and a backbone thoracal part       Thorax both dislocation  stretch and injury of both joints and capsular ligamen   tous apparatus       Trauma of both nerves and thoracal part spinal cord       Bruise  commotion   liver  lien  kidney         Thermal second degree burns  bubbles   loss of epidermic tissue     Additional spheres of application      Gerontology  general restorative therapy    1 3 Contraindications   e Inflammatory diseases at acute period    e Hemophilia    e Thrombocytopenia    e Purulent processes before surgical treatment   e Cardiovascular collapse of II   Ill degree    e Pregnancy    e Presence of an implanted cardiostimulator     1 4 Mechanism of magnetic fields physical and therapeutic effect   Action of magnetic field on an organism is characterized by        differences in individual sensitivity to magnetic field exposure      remedial effect of magnetic field on an organism and its functional systems      degree of therapeutic action intensity  effect and changes in organs are more  evident with the influence of alternating and pulsed magnetic field  than that of the  constant one        magnetic field application aftereffect  Reaction of an organism is kept within 
33. zing effect with traumas      improvement of conductivity function stimulating the restoration of injured pe   ripheric nerve endings functions  due to the better axons growth  myelination and in   hibition of connecting tissue development in them    Stimulation of hypothalamo hypohpysial system causes chain reaction of pe   ripheric endocrine glands activation under the influence of release factors    In endocrine system under the influence of alternating magnetic field with induc   tion up to 30 mTl  frequency up to 50 Hz during the little exposition  20 minutes   there is development of both training reaction and excess activity of all parts of  endocrine system    From the part of thyroid gland there is noted stimulation of its function under action  of magnetic field  in contrast to suppressive effect of many others stimulus   that  gives the background to use magnetic fields in complex therapy    The sympaticoadrenal system is slightly activated within the first procedures  and  by the 7  9 day there is inhibition of peripheric adrenoreceptors which plays the impor   tant role in the formation of antistress effect     Operating manual Page 6    POLYMAG 01    The influence of alternating traveling pulsed magnetic field on collar zone there is  a reaction from cardiovascular system that gives the ground to suppose the reflex  nature of these fields action      There is marked decrease of blood pressure in system of deep hypodermic veins  and arteries  simultaneously  incr
    