1. and Ultrasonic triggering mode The Sensor will be triggered and the load will turn on only when both of the PIR and Ultrasonic sensors detect movement The Sensor s green and red LEDs will turn on to confirm the detection To adjust Sensitivity of Ultrasonic By pressing buttons ultrasonic sensitivity on the Sensor can be adjusted Pressing each button will increase or decrease sensitivity by 10 The Green LED will flash to confirm the setting The Green LED will remain on for approx 2sec when the Ultrasonic sensitivity is at the highest or lowest level Note The first time sensitivity is adjusted on the sensor by these buttons it will start from 50 5 TROUBLE SHOOTING When the 752RC D remote controller works abnormally check the assumptive problems and suggested solutions in the following chart Problem Possible cause Suggested solution Sensor fails Have exceeded Operate in transmission range and to receive the transmission ensure the 752RC D aims directly signal range at the sensor No signal Low battery Replace battery sent from remote Fail to In lock mode Unlock the IR remote control transmit Press the unlock button before signal using the remote 3 28 0205400100300
2. H CLIPSAL by Schneider Electric USER MANUAL IR Remote Control CAT NO 752RC D TECHNICAL SPECIFICATIONS Rated Voltage 3V DC CR2032 battery Transmission Range Approx 3m Transmission Angle 35 Operating Temperature 0 C to 45 C Storage Temperature 25 C to 55 C 2 FEATURES You no longer need to climb ladders the ceiling mounted Occupancy Sensor can be programmed easily and safely with the 752RC D IR Remote Control By pressing CSD button the ambient light level can be recorded in to the sensor as the threshold for of switching on off the sensor s load Key Refer to function of GSD button chain gt A key chain hole is designed for easy hole carrying See FIG 1 RG 3 BATTERY REPLACEMENT Pull out the battery holder with a flat blade screwdriver and insert a new battery model CR2032 3V Please make sure the battery is connected to the correct polarities then insert the battery holder into the housing See FIG 2 Battery holder FIG 2 4 PUSH BUTTON FUNCTION Ensure to unlock Remote buttons before using it to set the Occupancy Sensor By using OJ button the settings of light level and time can be transferred to different sensors Each button will transmit a signal for maximum 1sec No signal will be transmitted if two or more buttons are operated simultaneously The Occupancy Sensor confirms the signal receiving by flash
3. evel e If the actual light level is within 5 1000Lux LEDs will keep on for 5s to confirm the successful learning and recording e If the actual light level is above or below of 5 1000 Lux LEDs will flash quickly for 5s to indicate this The sensor will learn the below settings 5Lux when actual light level is below 5Lux 1000Lux when actual light level is above 1000Lux Note Recommend to turn off loads before learning Button Function To set delay off TIME and turn on off the advance switching off function By pressing KOK button Load1 is selected to set the delay off time value The LED will flash toconfirm the Load selection By pressing the corresponding time value button the selected delay off time will be set to Occupancy Sensor Tip Press 60Min button three times quickly in 2s to enable the sensor s Advance switching off function Red LED will come on for 5s to confirm Repeat this operation again to disable this function Green LED will come on for 5s to confirm To save and transfer the Lux and Time settings from one Sensor to others 1 Set the desired Lux and Time values on one Sensor by using IR Remote Control 2 Then by pressing and holding the button for approx 3sec while pointing to the above Sensor the Lux amp Time settings of this Sensor will be saved into the IR Remote Control confirmed by the Sensor s LED flashing 3 By pressing button agai
4. ing the Green LED for 1sec f 3Hz Load 2 is not suitable for the single load Occupancy Sensor Function To unlock 752RC D buttons By pressing button IR Remote Control buttons will be unlocked Thereafter the remote can be used to set Occupancy Sensor Note The 752RC D buttons will be locked automatically if no button is operated for 2min To lock 752RC D buttons By pressing button IR remote control buttons will be locked Except button To reset settings on Occupancy Sensor By pressing button all settings on Occupancy Sensor will go back to the potentiometers settings and all MEMO data will be deleted To adjust Lux value By pressing corresponding button the selected light level threshold 10 30 100 or 1000Lux will be set to the Occupancy Sensor for switching on the connected load Tip Press 1000LUX button twice quickly in 2s to disable the light level threshold LEDs will come on for 2s The sensor will operate the load even in very bright ambient To reset a light level threshold just press the desired light level button To Learn and record the actual light level If above provided Lux values are not what desired the actual light level can be recorded in to the Occupancy Sensorby pressing Control The Occupancy Sensor will take below actions e Occupancy Sensor s red and green LEDs will flash for 10s one flash one second to learn the actual light l
5. n for approx 1sec while pointing to new Sensor the saved settings will be transferred to the new Sensor 4 Transfer the settings to multiple Sensors as desired by repeating above last step Notes If no data is saved in the IR Remote Control the Sensor will not react after pressing the button If battery is removed for more than 5sec or the RESET button is pressed the data in the Remote Control will be deleted TEST mode By pressing the LOK button the Occupancy Sensor will be set to Test mode This is used for walk testing of the sensor Under Test mode neither Lux nor Time settings on the Sensor are used See below e PIR US triggering mode Only both of PIR and ultrasonic are triggered the load and LEDs will be on for 2sec then off for 2sec before next triggering e PIR US triggering mode Either PIR or ultrasonic is triggered the load and corresponding LED will be on for 2sec then off for 2sec before next triggering e PIR only triggering mode Only when PIR is triggered the load and red LED will be on for 2sec then off for 2sec before next triggering e US only triggering mode Only when ultrasonic is triggered the load and green LED will be on for 2sec then off for 2sec before next triggering Short Impulse mode By pressing the Q button the Occupancy Sensor will be set to Short Impulse mode Under Short Impulse mode the Lux setting on Sensor is used but Time setting is not
6. pensation ON OFF 1 By pressing B button the air current compensation function will be activated It is confirmed by Sensor s LED keeping on for 5sec This will reduce the sensing range to 1 2m 2 By pressing B button air current compensation function will be deactivated It is confirmed by Sensor s LED flashing for 5sec To set PIR only triggering mode By pressing button Sensor will be set to PIR only triggering mode Sensor will be triggered andthe load will turn on only when the PIR sensor detects movement The Sensor s red LED will turn on to confirm the detection To set Ultrasonic only triggering mode By pressing button Sensor will be set to Ultrasonic only triggering mode The Sensor will be triggered and the load will turn on only when the Ultrasonic sensor detects movement The Sensor s green LED will turn on to confirm the detection To set PIR or Ultrasonic triggering mode By pressing button Sensor will be set to PIR or Ultrasonic triggering mode Sensor will be triggered and the load will turn on when either the PIR sensor or Ultrasonic sensor detects movement When the PIR Sensor is triggered the Sensor s red LED will turn on to confirm the detection When the Ultrasonic sensor is triggered the sensor s green LED will turn on to confirm the detection To set PIR and Ultrasonic triggering mode By pressing LDN button Sensor will be set to PIR
7. used See below e PIR US triggering mode Only both of PIR and ultrasonic are triggered the load and LEDs will be on for 1sec then off for 9sec before next triggering e PIR US triggering mode Either PIR or ultrasonic is triggered the load and corresponding LED will be on for 1sec then off for 9sec before next triggering e PIR only triggering mode Only when PIR is triggered the load and red LED will be on for 1sec then off for 9sec before next triggering e US only triggering mode Only when ultrasonic is triggered the load and green LED will be on for 1sec then off for 9sec before next triggering To set load ON for 8 hours By pressing button the load connected to the Sensor will be turned on for 8hrs Load will be turned off after 8 hours and return to Auto mode To cancel the 8 hours ON setting press the button again during the 8 hours period The 8 hoursON setting will also be reverted back to Auto mode if the power is cycled off then on again Button OO Function To set load OFF for8 hours By pressing the LON button the load connected to the Sensor will be turned off for 8hrs Sensor will return to Auto mode after 8 hours To cancel the 8 hours OFF setting press the cr i button again during the 8 hour period The 8 hour OFF setting will also be reverted back to Auto mode if the power is cycled off then on again To set ACC Air Current Com