1.      MANUAL    50021    HANDHELD INSTRUMENT FOR CO2 MEASUREMENT        made to measure    MANUAL       CONTENT   HANDHELD INSTRUMENT FOR CO2                                                      1  ONT EN Escuintla are ehe 3  T  GENERAL DESCRIPTION  na ae A  2  FUNCTION DESCRIPTION en ee A  3  DEFAULT PUSH BUTTON FUNCTIONS                                                                                         5  4  INSTANTANEOUS CO                                                                          6  5  TEMPERATURE seen ee ee 6  6  CHARGING OF BATTERY                                                     6  7  SELF DIAGNOSTICS AND                                                                   7      LOGGING CO  AND                                                             7  9  USER INTERFACE PROGRAM UIP P                                                  8  10  FILE HANDLING  amp  APPLICATION                                                       10  11  TECHNICAL SPECIFICATIONS man a 12    12  DATA SOON  sore 13            MANUAL       1  GENERAL DESCRIPTION    The SDO21 portable sensor is a light weight CO2 instrument with a digital display designed to  measure the carbon dioxide concentration in ambient air  The display shows the current carbon  dioxide concentration and temperature  Built in data logging for both CO2 and temperature makes  it perfect for worksite investigations  The gold plated carbon dioxide sensor measures the carbon  dioxide concentration in ppm
2.     handelskade 76  2280 cc rijswijk  the netherlands    p o box 1111  2288 bg rijswijk  the netherlands    tel   31 70 3070703  fax   31 70 3070938    info acin nl  www acin nl    made to measure    instrumenten bv       
3.   State of the art non dispersive infrared technology and automatic  calibration functions have resulted in great reliability  accuracy and long term stability of operation   The battery capacity is more than 12 hours     2  FUNCTION DESCRIPTION    The instrument is durable but can be extra secured by a safety strap on the top  The measuring  sensor is inside the unit  Two openings in the housing make the air circulate through the unit  These  Openings must be kept open     Please note    Whenever you go from a cold to a warm environment there is a risk of condensation  anyone with  glasses has noticed it   To avoid that this influences the accuracy of the instrument it is important to  allow it to adjust to the environment for a few minutes before usage     figure 1 figure 2  The flow throught the unit Front panel    On Off and Function button    A CO  concentration in ppm    Temperature  in Celsius   can  VA be reconfigured from PC to      Fahrenheit         status indicator    Red Led  High Alarm  9000 ppm CO     a 88 8         2nd Yellow Led  Low Alarm    2000 ppm CO     2nd Green Led    1st Yellow Led  600 ppm CO     1000 ppm          The display shows the instantaneous CO2 value and temperature  The instantaneous CO2 value is  also easily overviewed with the front panel LEDs         1st Green Led  Always activated in  On or Sleep Mode          Note  If the status indicator is shown the readings are not reliable  The actions to take are then  always first to charge the b
4.  icon lits continuously  The SDO21 unit automatically  stops charging when the battery is fully charged     The charging time for a completely discharged battery is 4 1 hours and the battery capacity is  more than 12 hours   figure 3  Connections    Calibration Gas Inlet DC Adapter    Communication Port       MANUAL                  7  SELF DIAGNOSTICS AND CALIBRATION    The 50021 is basically maintenance free  The system contains complete self diagnostics  executed  automatically every time the power is turned on  The unit will then perform a full self test sequence  showing the LEDs response for the turn on set points  SDO21 is working with continuous self diag   nostics during operation  On Mode   If any error is detected  then the Status Indicator Segment will  be lit     The sensor has an automatic calibration function to secure long term accuracy  It   s called Automatic  Baseline Calibration  ABC   implemented to eliminate any zero point drift of the infrared sensor  ABC  calibration cycles are performed in 4 hours intervals  During some minutes of that time fresh air   CO2 concentration between 380 420 ppm  has to be present  ABC function is only active in    CALb  Mode     after one hour delay  and requires 1 to 5 hours to perform one calibration adjustment   Each such adjustment is limited to a calibration tuning of about 130 ppm CO2  Several consecu   tive adjustments might be performed  if required  for each additional 4 hours period stay in    CALb  Mode        T
5.  of recorded data resets to zero  as is the case if manually  setting 50021 in Off Mode without battery charger connected   The old data still remains  however   until new recordings eventually overwrite it  After a power up such    lost    data may be recovered  by selecting    Update    with the right mouse button            UIP P SenseAir  00 04 39        C0      Temperature       3 minutes 6 seconds                    3 minutes 6 seconds               figure 7     Recovery     memory dump  of yesterday   s recording  Figure 6       using    Update    with right mouse  click  The arrow points at a data discontinuity indicating the memory position of the sample counter  just before the power was lost             MANUAL       10  FILE HANDLING  amp  APPLICATION FILES    Together with a communication cable  accessory  and the user interface program UIP P it is pos   sible to select from a directory and load different application files into SDO21  An application file will  customize the unit for a certain professional application  Typically  the application file adds to the  default unit some mathematic algorithm that will be executed by the push button when the unit is in  On Mode  Also  the display options will be enhanced and include the result of this extra function     50021 plans to build up with time a library of different such application files  These files are free  and are included in the UIP_P software package  which can be downloaded from SD021   s web  site www SD
6. 021 com  You are welcome to suggest new and suitable applications for this library by  contacting your distributor     To load an application file from the library into the unit  proceed as follows    e Connect the cable and start the UIP_P software to establish the PC connection   e You might want to save the existing unit configuration for future restoration  If so  select main  menu    File         Save settings to file    and select some appropriate file name    e Select the main menu    File         Load settings from file    and select the application file of interest   e When the file has been loaded onto the PC screen you might want to edit the default display  configuration and select SI or English US units   this is the time to do it    e When you have made your selections you must click on    Send to sensor         e Exit the software when finished and turn off the sensor power  with no battery charger con   nected      After power up the unit has its new operation functionality  You are free to reconfigure back and  forth as much as you like  but to be sure of correct operation you must completely power down the  monitor before operating with a new application configuration        Save Load backup file    are two other file options available from UIP_P These options will store re   call exact copies of one and the same unit at a certain time  including calibration parameters in ad   dition to the exact configuration  The unit serial number is used as a locking par
7. O2 and temperature by 896 samples  Logger resets in Off Mode    Windows 95 98 NT compatible software to    define personal user preferences     support sensor calibrations     transfer and save logged data     view trend curves of logged data    6VDC   700 mAh  with NOKIA type miniature connector  3 6 VDC   1350 mAh Li ion accumulator    gt  12 h  capacity    lt  55 mA in normal mode    EMC Directive 89 336 EEC    20   to  70  C   0   to  50        0 to 95   RH  non Condensing     gt  15 years    gt  3 years   complete power sensor  internal checks  LCD triangle icon   maintenance call   lt  30 sec   full specs  lt  15 minutes   ABS PC blend   123X52 X 32 MM   135g    MANUAL    ACCESSORIES  Accessories  includes   monitor with internal battery  protective casing  communication cable    wall plug battery charger    Optional accessories art no    PC communication cable A232 0740   Battery charger A 0741 charger  for car use 12V    Extra battery charger A 0740 charger  Replacement battery 1PSC340848 1350  Extra protection case 0741 bag    12  DATA SDO21             o    serialnumber                                        nn nun nun    delivered to     company ao  CONTact perso iria ico                            Teer  ades O 6                           telephone       _    __ raise  Small  0 eo rocio    AA O A lada ia    Return adress for maintenance   De Bruyn Kopsstraat 5 2288 EC Rijswijk The Netherlands          13          MANUAL       14       MANUAL    acin instrumenten bv
8. ameter preventing  the file to be loaded into any other monitor with a different serial number     Current application file library  SD021 Application File     standard     File name  00003 50021 std set    Description  The standard setting as described in this user manual  The push button only triggers  the backlight     10    MANUAL       SD021 Application File     Ventilation Rate      File name  00256 50021 Vent rate set   Description  This application is intended for building owners  health care and energy savings con   sultants  providing a convenient tool for the investigation of fresh air ventilation rates in buildings  occupied by humans  The extra function provided is that the 50021 unit calculates and displays the  fresh air Ventilation Rates based on the difference between indoor and outdoor CO2 levels  The unit  assumes that a steady state condition is present  with ventilation balance between CO2  generated  by the tenants inside the space  and fresh air  provided by the total ventilation system     The unit further assumes a tenant activity level of 1 2 MET units  which equals to a CO generation  rate of 0 30 litres minute  typical office labour activity   The  50021 user is advised to first measure  the outdoor CO2 value and store this value into the unit by pressing the push button  The text     rEAd    acknowledges the sampling of the outdoors CO2 value     Steady state formula used for fresh air Ventilation Rates    SI  metric  units   Ventilation rate in l
9. attery  second to recalibrate the CO2 sensor zero point  put the unit  in CALb Mode   If still the status indicator is shown after these two actions  please contact your  dealer     MANUAL       3  DEFAULT PUSH BUTTON FUNCTIONS    On Mode  measuring CO2  measuring temperature  logger active  ABC algorithm disabled    Power Off  e logger resets and the sample  counter will be lost    CALb Mode  e logger on hold  e ABC algorithm enabled    Back light  amp  Application  Function Execution    Push te button until the display shows    tESt   then release the  button  The unit will perform a full self test sequence showing  the LEDs response for the alarm set points  After the test the  unit is in On Mode     Off Mode Explanation      Push Button    Release Button    From On Mode  push the button until all front panel LEDs are  turned off  While pushing the button the unit will pass through  the mode CALb  If you accidentally release the button too ear   ly  just push the button one to reach On Mode and try again          CALb       Off Mode    From On Mode  push the button until the display shows CALb   then release the button  This will activate the Automatic Cali   bration ABS that requirers 5 hours to complete one calibration  cycle  The instrument continues to execute calibrations every  four hours as long as it is left in CALb Mode  Intended for over   night charging in fresh air  with minor calibration adjustment  automatically performed    To get back to the On Mode  just p
10. he CALb Mode is intended for overnight charging in an area with good ventilation  or close to the  fresh air inlet     8  LOGGING CO  AND TEMPERATURE    50021 continuously logs the CO2 and temperature values  To use this feature    PC and a special  serial cable is required  together with the SDO21 freeware UIP_P  available at www SD021 com    This is useful  for example  when you are investigating ventilation systems  or doing worksite inves   tigations  over several days  Each ofthe two parameters can be logged up to 896 samples in a FIFO  memory  first in first out      The default sampling interval is 10 minutes  which results in more than  6 days and nights of recording time     If the unit is turned on for a longer period old data gets eventually over written  keeping the records  of the last recorded 896 data samples  Depending on selected sample interval you can make longer  or shorter investigations over time  The logger is always active in On Mode  To reset the logger  just  switch off the unit  without any battery charger connected  and turn it on again  That will force the  sample counter to start from zero     In CALb  the logger function is kept on hold  This is useful when you want to take a pause in meas   uring  for example  if you are doing a worksite investigation and have to leave the area for some  period  When the unit is switched back into On Mode it will resume the started recording period   Switching the unit into OFF Mode  with the battery charger co
11. itres second person  Ventilation rate    5000    CO  CO    21           2Outside       English US units   Ventilation rate in CFM per person  cubic feet of air per minute per person   Ventilation rate     5000     CO       2 x2 12    2Inside Outside          The ventilation rate can be displayed in SI units  litres second person  or in English US units  CFM  per person  as selected from the LCD map in the UIP P software     To use the Ventilation Rate function   The upper and lower parts of the display toggles between two sets of readings  the current ambient  CO2 level and temperature during one half period of time  and the outdoor CO2 level sample and  the calculated fresh air ventilation rate during the next half period  The ventilation rate displayed   however  will have no meaning until you have sampled a relevant outdoor CO level and entered a  building  The procedure is     1  With the SD021 in On Mode  first put the  0021 in the reference media  CO2Outside  and wait  until the readings has stabilized  Press the button until the display acknowledges    rEAd     indi   cating that the sensor has now sampled the outdoor CO level    2  Place  0021 in the space you want to study  CO2Inside  and wait until the reading has stabi   lized before you make notes on the ventilation rate  Be aware not to contaminate the monitor  readings by your own exhale     11    CIN       MANUAL    11  TECHNICAL SPECIFICATIONS    SPECIFICATIONS    CARBON DIOXIDE MEASUREMENT    Operating Princi
12. nnected until switched back into ON  Mode again  will also pause and resume the data logging     It s preferred to start a logging period with a fully loaded battery and avoid charging  Charging the  battery generates extra heat inside  50021 that will interfere with the temperature measurements     Please  remember  Putting SDO21 in Off Mode without any battery charger connected will reset to  zero the sample counter from the previous logged data  The data   tself remains  however  until new  recordings eventually over write it     C      MANUAL       9  USER INTERFACE PROGRAM UIP P    UIP P is a freeware and can be downloaded from www SD021 se  Together with a serial communi   cation cable  art  no  A232 0740 offered as accessory  you can connect the 50021 unit to a PC for  functional reconfigurations of the unit  for sensor maintenance  and to do data extractions from the  internal data logger  This data communication can be performed in OFF Mode during battery charg   ing  as well as during normal operation in ON or CALb Modes  with or without any battery charger  connected         E02            _  feo   Tempera                         9  an          figure 4  LED set points and LCD configuration options available in the user interface program UIP P    50021 Customizations  User Preferences     Maintenance   UIP P is a PC software tool that gives access to a number of different maintenance and configura   tion options  lt provides a number of functions to customize the u
13. ple   Gas Sampling Mode   Response Time  1 e   Measurement Range   Extended Range   Accuracy at NTP   25   C   Pressure Dependence   Automatic Background Calibration    LEDs  Numerical Liquid Crystal Display    TEMPERATURE   Operating Principle  Measurement Range  Accuracy   LOGGER AND SOFTWARE  Digital Interface   Internal Data Logger   PC software    ELECTRICAL   Battery Charger Input  Internal Battery   Battery Current Consumption  GENERAL PERFORMANCE  Compliance with   Storage Temperature Range  Operating Temperature Range  Operating Humidity Range  Sensor Life Expectancy  Battery Life Expectancy  Self diagnostics   Status Indicator   Power up Time   Housing Material  Dimensions  L x W x D    Total Weight    12    Non dispersive infrared  NDIR  with gold plated optical cell  Diffusion   2 min diffusion time  amp  15 sec at 0 2 litre min gas flow   0 6000 ppm   6000 10 000ppm  accuracy not specified    3   of reading or   20 ppm   whichever is greater     1 6   reading increase per kPa deviation from normal pressure    Automatic Background Calibration with fresh air  Can be done together with charging during the night     5 stages green green yellow yellow red LED bar graph displaying current CO2 concentration    Simultaneous display of     the current CO     temperature     ventilation rates  user configuration     Thermistor  0 50   C  0 5   C  provided that the battery charger is not connected and the unit    USB connector with sensor UART RS232 COM driver  Logging of C
14. ser application    e Configure the trigger levels for the five LEDs    e Customize display  Which parameters shall be visible for the user    e Select display readings in Sl or English US units   e Save and load application and customized files    e Make CO2 and temperature sensor calibrations     u  UIP P SenseAn    Calibrate       figure 5  Calibration options provided by UIP P    MANUAL       50021 internal data logger  The internal data logger is active in On Mode ern a a  and resets in Off Mode  resets only if battery  charger is not connected   All samples taken  during the turn on time  max 896 samples   can be viewed with the User Interface Program  UIP P    From UIP P it is also possible to save all data in  a PC text file for storage or further data process   ing  for instance  in EXCEL or any other spread  sheet software                 figure 6    Figure 6 shows an example of a 46 hours recording extracted from the SDO21 unit using UIP P Note  the influence on temperature readings from battery charging  as the charger was connected during  the first 22 hours  This graph also shows that the unit was fully functioning without any power con   nected over the last 24 hours  twice the rated portable operation time     Selecting    Update    in the UIP P    Logger history    map will only display data up to the time position of  the sample counter  If battery operating time exceeds  the unit will automatically switch off and the  sample counter from the previous session
15. ush the button once        CALb       Can be turned on temporarily by pushing the button  The  backlight is turned off after 8 16 seconds  Application function  for standard default setting is just backlight                MANUAL       4  INSTANTANEOUS CO  CONCENTRATION    The instantaneous CO2 concentration is shown in the upper part of the display  A rough picture of  the CO2 concentration is also given by the five LEDs found below the display     LED indicator functions  factory settings      Green 1 always lit when the unit is on  Green 2  gt  600 ppm  Yellow 1  gt 1000 ppm  Yellow 2  gt 2000 ppm  Red 2  gt 5000 ppm    5  TEMPERATURE    Temperature is presented in Celsius  but can be reconfigured from PC to be in Fahrenheit  To meas   ure an accurate reading in ambient air  the unit should be hanging in the safety strap  That orienta   tion minimizes interference from internal heat sources  The sensor may take some half an hour to  reach thermal equilibrium and accurate readings     Note  Charging the unit will result in a temperature rise inside the unit that disturbs the temperature  measurement     6  CHARGING OF BATTERY    Charging of the battery can be done with the unit in Off   CALb  or On Mode  The electronic circuitry  gets activated by charging also in Off Mode  but will return to initial state when disconnected  When  the DC  adapter is connected the charging of the battery is indicated by the rolling battery icon   When the battery is fully charged the battery
    