Home

CSE-M53 User`s Manual

image

Contents

1. O Add Related Material contents O Modify some expressions Operating Storage Temperature have been changed L SOLLAE SYSTEMS 62 http www ezTCP com
2. command For more information about this please refer to the ATC mode on the Download gt gt Technical Document menu of our web site Z SOLLAE SYSTEMS 37 http www ezTCP com CSE M53 User s Manual Ver 2 0 5 4 UDP UDP has no processes of connection In this mode data is sent in block units Therefore data that comes through CSE M53 s serial port must be classified in block units to send it elsewhere 5 4 1 Key parameters Block Size Byte Block Size Byte means the size of a block in UDP mode Its unit is byte The size of bytes are come into the serial port CSE M53 sends them as one block to the network The maximum value could be 1 460 bytes Data Frame Data Frame means the time for gathering data to make one block Its unit is 10ms If there are no transmission during the time which is set to this value CSE M53 sends gathered data in the buffer as one block to the network Once one of the parameters is sufficient the block size is decided as the condition Dynamic update of Peer host If users set the value of Peer Address and Peer Port to 0 dynamic update of peer host function is activated By using this function CSE M53 can communicate to multiple hosts without additional setting L SOLLAE SYSTEMS 38 http www ezTCP com CSE M53 User s Manual Ver 2 0 5 4 2 Examples Block Size 5 bytes Data Frame 1s 100 by 10ms Figure 5 10 time ch
3. port fmax rbmax rxbuf txbuf rx count tx count Figure 6 5 st sio command st uptime st uptime command shows amount of time since CSE M53 boots up Ish st uptime 00 04 21 79 up 0 davs Iso Figure 6 6 st uptime command 9 sc sc command is used when users close a session opl means the name of session and op2 should be close sh gt sc coml close closed Figure 6 7 sc command In case of the sc command you should use only small letters Z SOLLAE SYSTEMS 44 http www ezTCP com CSE M53 User s Manual Ver 2 0 6 2 2 Using ezManager Status of CSE M53 can be monitored by Status button on ezManager By using the Refresh Every 1 Second option in the status window the status is automatically updated in every second at x Status IRMWARE VERSION CSE MS3 1 0 Rev C MSSRIOC BIN Bll STEM UPTIME D days 00 06 15 98 P4 NETWORK INFORMATION Device IP address 10 1 0 1 Subnet mask 255 0 0 0 Gateway 0 0 0 0 Name Server 0 0 0 0 IP CP STATE COML LISTEN ERIAL STATUS COMl sio rx 0 net tx 0 net rx 0 sio tx 0 RP TABLE 10 16 1 186 00 03 ff a0 bl 03 57 TCP IP Connection LISTEN 23 LISTEN 1470 Auto Update Refresh Every 1 Second Figure 6 8 status window of ezManager FIRMWARE VERSION The name of model name and the version of firmware are displayed her
4. 1 Figure 5 2 time chart for a situation that Event Byte is set to 1 Points States CSE M53 is listening to connection requests Remote host has sent a connection request SYN segment Processes of the connection The connection has been established The data 123 has been sent right after the end of connection processes Table 5 3 states of each points As you can see the data 123 has been sent right after the connection is established because the value of Event Byte had been set to 1 If the value is not 0 the result is the same as above example Z SOLLAE SYSTEMS 28 http www ezTCP com CSE M53 User s Manual Ver 2 0 A situation that Timeout is set to 5 Figure 5 3 time chart for a situation that Timeout is set to 5 Points States Data communication on both sides The last segment has been arrived at the CSE M53 5 seconds are passed with no data communication CSE M53 has sent disconnection request FIN to a remote host Processes of the disconnection The connection has been terminated CSE M53 is listening to connection requests Table 5 4 states of each points Z SOLLAE SYSTEMS 29 http www ezTCP com CSE M53 User s Manual Ver 2 0 5 2 TCP Client In this mode CSE M53 functions as a TCP client CSE M53 sends request segments to a remote host with information of Peer Address and Peer Port Once a
5. 2 0 7 2 Notify IP Change CSE M53 can be TCP server even though it assigned IP address automatically Using Notify IP Change function CSE M53 sends its IP address with the host name to the designed server There are 3 types DDNS TCP and UDP for this service Dynamic Domain Name Service DDNS CSE M53 supports DDNS service offered by DynDNS Therefore you have to make an account and create host names on the website of DynDNS before you use All about service usage of an account could be changed according to the policy of DynDNS Homepage of DynDNS http dyn com r Notify IP Change Protocol Interval DNS dyndns o 40320 Minute s Se 2 Port DDNS ID DDNS Password 3 account en e a Host Nane dyndns yournostnane dyndns org e 6 Figure 7 1 setting DDNS Select the DDNS dyndns org 40 320 is a fixed value Input the ID of DDNS account Input the password of the account Input a host name which you create on your account TCP UDP In case you have an own server and want to manage the information about changed IP addresses you allowed used TCP UDP for using this option The Data Type can be selected as ASCII or hexadecimal and the Interval is available on configuration L SOLLAE SYSTEMS 51 http www ezTCP com CSE M53 User s Manual Ver 2 0 7 3 Sending MAC Address Sending MAC Address is a function that CSE M53 sends its MAC address to the remote
6. EEE E E N N an 11 1 6 Evaluation le an RREN 12 LOL JANS eaea rA E cesta seca E EE E E Poses eee 12 LG E EE 14 2 Installati n and NC 15 2 Installation nee 15 21 1 Setting Network Aera ERREUR nerede 15 22 Simple EE 17 3 Configuration EE 20 3 1 Configuration with ezManager nn 20 3 11 Configuration via LAN 20 342 Configuration EE 21 Bs 2 ATCO ANG erneer nand dnek eee ennemies 22 4 Operation Modes uere EECHER ERC 23 4 1 What is the Operation Mode 23 4 2 How to entering each mode nece nnn 23 43 Comparison with GACH mode iere 24 4 4 Normal MOGG ino EE EE 24 4 5 Serial Configuration Mode nete edipi ted ite e rinii 25 AO ISP Modene neo mn no ie iii 25 461 Upgrading Firmware 225 L SOLLAE SYSTEMS 2 http www ezTCP com CSE M53 User s Manual Ver 2 0 4 6 2 Revoking Serurity ODHIONS nn 25 5 Communication Modes nsvsnenenvenenvenenenvenenveneneevenenveneneenenennenenveneneenenense 26 3A TCP SENO 26 SLL KEV parameters eer Ug aen ra Ese edens 26 IL LL 27 ALS EEE 30 EE 30 DA EE 31 5 3 AT C OMMAN A ae ne cn ue 34 E 34 BDZ EE ns M 35 SATUD PR ae tu on re tune EEC 38 SAL Key parameters unne nennen 38 EE EE te tee UEM tie 39 6 System Manage
7. PLP Local Port AT PLP 1470 lt CR gt PRIP Peer IP Address AT PRIP 10 1 0 2 lt CR gt PRP Peer Port AT PRP 1470 lt CR gt PDC DHCP AT PDC 1 ON lt CR gt PPE PPPoE AT PPE 1 ON lt CR gt PTO Timeout AT PTO 10 lt CR gt PWP Store setting AT PWP lt CR gt Table 5 10 some of extended commands for configuration Related items with IP Address and Local Port Local port can be set as well as IP address related parameters like IP Address Subnet Mask and Gateway IP Address Peer Address Peer Port IP address and local port of a remote host are can be set Type of assigning IP address Manual DHCP PPPoE Not only manual setting also automatic assigning protocol DHCP PPPoE are available Others Some of options including Timeout can be configured in this mode L SOLLAE SYSTEMS 34 http www ezTCP com CSE M53 User s Manual Ver 2 0 5 3 2 Examples TCP Server setting parameters and passive connection ee perterminal Figure 5 7 TCP passive connection Points States Set parameters in the AT command mode CSE M53 listens TCP connection requests with the ATA command CSE M53 is listening TCP connection requests A remote host has sent SYN segment to CSE M53 Processes of TCP connection TCP connection has been established CSE M53 sends CONNECT message to the serial por
8. When producing the product Z SOLLAE SYSTEMS 12 http www ezTCP com CSE M53 User s Manual Ver 2 0 LED Group 1 Description Blinks when CSE M53 receives data from the serial port Blinks when CSE M53 sends data to the serial port On when CSE M53 is available on receiving data On when CSE M53 is available on sending data On when CSE M53 is connected with a remote host on TCP Table 1 6 LED Group 1 D TTL Port For 3 3V TTL logic level communication LED Group 2 Description Blinks when CSE M53 receives data from the Ethernet port Blinks when CSE M53 sends data to the Ethernet port On when CSE M53 is connected with the Ethernet On when CSE M53 is connected with a remote host on TCP Blinks in every second when CSE M53 is in normal mode Blinks 4times at once when any IP addresses have not been assigned to CSE M53 from DHCP or PPPoE servers Table 1 7 LED Group 2 Reset S W S W for re supplying the power to the EVB JP7 A port for changing modes Division 3 3V ISP GND Normal ISP Serial Configuration Fig 1 4 JP7 for Changing modes LED Groups 3 and 4 Name Description PWR D10 On when the power is supplied to the EVB Slowly Blinks when the power is supplied to the CSE M53 D1 Shortly Blinks when the CSE M53 is operates in ISP mode Table 1 8 LED Groups 3 an
9. com CSE M53 User s Manual Ver 2 0 Applied to the Internet on Cable Networks Server PC d ai Cable Modem INTERNET A Serial Device A Cable Modem Figure 1 3 applied to the Internet on cable networks Applied to the Internet with an IP Share Router Cable Modem IP Share Router LAN Server PC 1 e Figure 1 4 applied to the Internet with an IP share router 1 4 Components CSE M53 s Body Evaluation Board for CSE M53 Option RS232 Cross Cable Option DC 5V Power Adapter Option Z SOLLAE SYSTEMS 7 http www ezTCP com CSE M53 User s Manual Ver 2 0 1 5 Specification 1 5 1 Hardware Input Voltage DC 3 3V Power 24 mm x 20 mm x 9 1mm Cortex M3 Core RS232 RTS CTS and Xon Xoff Flow Control Serial Port TTL 3 3V Logic Level Interface Baud Rate 300bps 921 600bps 10 Base T or 100 Base TX Ethernet Auto Sensing Auto MDI or MDIX cable Auto Sensing Operating 20 70 C Storage 40 85 C RoHS Compliant Table 1 1 Hardware specification Network 1 5 2 Software 5 TCP UDP IP ICMP ARP DHCP PPPoE Telnet DNS Lookup DDNS rotoco TELNET COM port Control Option RFC 2217 For Normal Data Communication Operation 7 mode Serial Configuration For Configuration via Serial TCP Server TCP Passive Connection Communicat TCP Client TCP Active Connection ion mode AT Command TCP Passive Active Connection Configuration Utility for MS Wind
10. host right after the connection is established By using this function a server can identify multiple devices with the information Network Serial Port Option v Telnet V IP Address Search V Send MAC Address Debugging Message DO E Multiple Connection Dikssx o Figure 7 2 setting of Sending MAC Address function Move to the Option tab Q Check the Send MAC Address option 7 4 TELNET COM port Control Option RFC 2217 This option is for sending and receiving serial port states between two devices Users can send and receive control signals like RTS CTS when the states are changed COM gt Serial Port r TCP IP Serial Type TTL Communication Mode rs 232 DI r rzs TCP Server gt Baudrate Peer Address Peer Port 15200 1470 Parity Local Port nonz D 1470 Iu TCP Server Data Bits Event Byte 8 D Stop Bit Timeout 0 P bit Data Frame Interval lOms Flow m 7 HI NONE 7 GI IV Telnet COM Port Control RFC2217 J DIEDER ica e U v amcmaccann ala Figure 7 3 setting of TELNET COM Port Control option Move to the Serial Port tab Q Check the Telnet COM Port Control RFC2217 option If you want details about the TELNET COM port Control Option and Sending MAC Address please refer to the documents on the Download Technical Document of our website SOLLAE SYSTEMS 52 http www ezTCP com CSE M53 User s Manual Ver 2 0 8 Self Test i
11. 0 11 2 2 French version Documentation La documentation du CSE M53 est con ue avec la plus grande attention Tous les efforts ont t mis en ceuvre pour viter les anomalies Toutefois nous ne pouvons garantir que cette documentation soit 10096 exempt de toute erreur Les informations pr sentes dans cette documentation sont donn es titre indicatif Les caract ristiques techniques peuvent changer tout moment sans aucun pr avis dans le but d am liorer la qualit et les possibilit s des produits Copyright et appellations commerciales Toutes les marques les proc d s les r f rences et les appellations commerciales des produits cit s dans la documentation appartiennent leur propri taire et Fabricant respectif Conditions d utilisations et limite de responsabilit En aucun cas Sollae Systems Co Ltd ou un de ses distributeurs ne pourra tre tenu responsable de dommages quels qu ils soient int grant mais sans limitation les dommages pour perte de b n fice commercial interruption d exploitation commerciale perte d informations et de donn es caract re commercial ou de toute autre perte financi re provenant de l utilisation ou de l incapacit pouvoir utiliser le CSE M53 m me si Sollae Systems Co Ltd ou un de ses distributeurs a t inform de la possibilit de tels dommages Le CSE M53 est exclusivement pr vu pour un usage en int rieur dans un environnement sec temp r
12. 10 C 40 C et non poussi reux Le CSE M53 n est pas pr vu ni autoris pour tre utilis en ext rieur ni de facon embarqu e dans des engins mobiles de quelque nature que ce soit voiture camion train avion etc ni en milieu explosif ni dans des enceintes nucl aires ni dans des ascenseurs ni dans des a roports ni dans des enceintes hospitaliers ni pour des applications caract re m dical ni dans des dispositifs de d tection et d alerte anti intrusion ni dans des dispositifs de d tection et d alerte anti incendie ni dans des dispositifs d alarme GTC ni pour des applications militaires De m me le CSE M53 n est pas con u ni destin ni autoris pour exp rimenter d velopper ou tre int gr au sein d applications dans lesquelles une d faillance de celui ci pourrait cr er une situation dangereuse pouvant entrainer des pertes financi res des d g ts mat riel des blessures corporelles ou la mort de personnes ou d animaux Si vous utilisez le CSE M53 volontairement ou involontairement pour de telles applications non L SOLLAE SYSTEMS 60 http www ezTCP com CSE M53 User s Manual Ver 2 0 autoris es vous vous engagez soustraire Sollae Systems Co Ltd et ses distributeurs de toute responsabilit et de toute demande de d dommagement En cas de litige l enti re responsabilit de Sollae Systems Co Ltd et de ses distributeurs vis vis de votre recours durant la p riode de garan
13. Embedded Serial Ethernet Converter CSE M53 User s Manual Version 2 0 Sollae Systems Co Ltd http www ezTCP com CSE M53 User s Manual Ver 2 0 This symbol found on your product or on its packaging indicates that this product should not be treated as household waste when you wish to dispose of it Instead it should be handed over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed information about the recycling of this product please contact your local city office household waste disposal service or the retail store where you purchased this product X This equipment obtained certification by using 1 5M serial cable L SOLLAE SYSTEMS 1 http www ezTCP com CSE M53 User s Manual Ver 2 0 Contents EE ilt e 5 IE SO II 5 EMU 5 T3 Application Examples 5 heresi ep ERREUR ESTHER ERREUR 6 MAE enn ee EE zem TS EE 8 ESL E 8 152 MMOL HT m 8 DDS DOMINO SION M sug RS MNS 10 RE E 11 1 5 6 An Application CIFCUIL sidere VE AEK E T
14. LLAE SYSTEMS 49 http www ezTCP com CSE M53 User s Manual Ver 2 0 7 Additional Functions 7 1 Security 7 1 1 Restriction of Access ezTCP Firewall On the Option tab of ezManager users can set restriction of access function with filtering MAC and IP address Allowed MAC Address If this option has a value of MAC address the device which has the MAC address is only permitted to access Allowed IP Address This is for qualifying hosts with IP address or range of IP address The range is defined by multiplying IP address and Network Mask in bit unit Examples IP Address Network Mask Allowed IP Address Range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 10 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Table 7 1 examples of defining allowed IP range Apply to ezManager Apply to ezManager is for applying above two restrictions to ezManager functions like Search Read Write and etc 7 1 2 Setting Password A password can be used for protecting CSE M53 from TELNET login or changing environmental parameters by hosts which are not qualified The maximum length is 8 bytes of Alphabet or number When you want to revoke all of these restrictions operate CSE M53 as ISP mode In the mode all restrictions are removable and communication with ezManager is revoked L SOLLAE SYSTEMS 50 http www ezTCP com CSE M53 User s Manual Ver
15. T PWP command y Figure 3 6 procedures for configuration with AT command Division Available parameters Local IP Address DHCP PPPoE Subnet Mask Gateway IP Address DNS IP Address Local Port Peer Address IP Address or Host name Peer IP Address related items TCP connection related items Port Option ESC code sending option timeout Table 3 1 parameters which are available to change with AT command Including above items rest of parameters can be set by ezManager L SOLLAE SYSTEMS 22 http www ezTCP com CSE M53 User s Manual Ver 2 0 4 Operation Modes 4 1 What is the Operation Mode Each of three operation mode of CSE M53 is defined for specific purpose and those are followed Normal mode This mode is for normal data communication and has 4 different connection modes Configuring parameters is also available in this mode Serial configuration mode This mode is for configuring environmental parameters through the RS 232 port ISP mode This mode is for upgrading firmware In addition you can set environmental parameters even though the security options like password are activated by entering this mode 4 2 How to entering each mode Normal Mode Reset or turn the Power off Res eer inpyg of Set ISP pin to LOW over 1 second Configuraion Mode ISP Mode Figure 4 1 How to entering each mode Because t
16. art for block size is 5 bytes and data frame is 1s States CSE M53 is receiving data from the serial port CSE M53 Sends 5 bytes as one block based on the Block Size Serial device sends data 678 to the CSE M53 Data 678 has arrived CSE M53 sends data from the remote host to the serial device 1 second has passed CSE M53 sends data 678 based on the Data frame Table 5 14 states of each points Z SOLLAE SYSTEMS 39 http www ezTCP com CSE M53 User s Manual Ver 2 0 Dynamic Update of Peer host This is a function that CSE M53 automatically sets its peer host with information of the last packet which is received from network In the packet the source address and port number is used Parameters Peer Address Peer Port States Remote host 2 sends data to CSE M53 CSE M53 sets host 2 to peer host Remote host 1 sends data to CSE M53 CSE M53 updates host 1 to peer host Remote host 2 sends data again to CSE M53 CSE M53 updates host 2 to peer host CSE M53 can communicate with remote host 2 Table 5 16 states of each points The data ABC DE FGH are from the serial port of CSE M53 in the above figure Z SOLLAE SYSTEMS 40 http www ezTCP com CSE M53 User s Manual Ver 2 0 6 System Management 6 1 Upgrading Firmware 6 1 1 Firmware Firmware is a type of software for operation of CSE M53 If there are ne
17. cations in nuclear applications in airport applications or for use in applications involving explosives or in medical applications or for use in security alarm or for use in a fire alarm or in applications involving elevators or in embedded applications in vehicles such as but not limited to cars planes trucks boats aircraft helicopters etc In the same way the CSE M53 is not designed or intended or authorized to test develop or be built into applications where failure could create a dangerous situation that may result in financial losses damage to property personal injury or the death of people or animals If you use the CSE M53 voluntarily or involuntarily for such unauthorized applications you agree to subtract Sollae Systems Co Ltd and its distributors from all liability for any claim for compensation Sollae Systems Co Ltd and its distributors entire liability and your exclusive remedy shall be Sollae Systems Co Ltd and its distributors option for the return of the price paid for or repair or replacement of the CSE M53 Sollae Systems Co Ltd and its distributors disclaim all other warranties either expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose with respect to the CSE M53 including accompanying written material hardware and firmware L SOLLAE SYSTEMS 59 http www ezTCP com CSE M53 User s Manual Ver 2
18. ced button for adding an IP Address like the below figure TCP IP Address ki x IP address 0 1 0 2 Subnet mask 255 0 0 0 Cancel Figure 2 2 adding changing the IP address of users PC L SOLLAE SYSTEMS 15 http www ezTCP com CSE M53 User s Manual Ver 2 0 Setting of CSE M53 CSE M53 uses ezManager as its a configuration program ezManager is for MS Windows and this is comfortable to use because it doesn t need installation First search your CSE M53 via network All the values of parameters are set the default values in the factory To apply it to your system proper values should be set via ezManager Major parameters default values are listed on below table To implement this simple test keep these values without any changes Name Default Values Network Local IP Address 10 1 0 1 Subnet Mask 255 0 0 0 Option TELNET Checked IP Address Search Checked Serial Port COM1 Serial Type RS232 Baud Rate 19 200bps Parity NONE Data Bits 8 Stop Bit 1 Flow Control NONE Communication mode TCP Server Local Port 1470 Table 2 1 default values of Major parameters Users can download the latest version of ezManager on the Download gt gt Utilities menu of our website Detail manners of the configuration are explained on the 3 1 Configuration with ezManag
19. d Use of firmware and applications provided by Sollae Systems for purposes other than those for which they were designed is prohibited Do not use the product in an extremely cold or hot place or in a place where vibration is severe Do not use the product in an environment in which humidity is high or a lot of oil exists Do not use the product where there is caustic or combustible gas Sollae Systems does not guarantee normal operation of the product under the conditions a lot of noise exists Do not use the product for a purpose that requires exceptional quality and reliability relating to user s injuries or accidents aerospace aviation health care nuclear power transportation and safety purposes Sollae Systems is not responsible for any accident or damage occurring while using the product L SOLLAE SYSTEMS 58 http www ezTCP com CSE M53 User s Manual Ver 2 0 11 2 Exemption from Liability 11 2 1 English version In no event shall Sollae Systems Co Ltd and its distributors be liable for any damages whatsoever including without limitation damages for loss of profit operating cost for commercial interruption loss of information or any other financial loss from the use or inability to use the CSE M53 even if Sollae Systems Co Ltd or its distributors have been informed of such damages The CSE M53 is not designed and not authorized for use in military appli
20. d 4 JP3 A port for enabling or disabling outputs of RS232 line driver Disable this port when using TTL level L SOLLAE SYSTEMS 13 http www ezTCP com CSE M53 User s Manual Ver 2 0 1 6 2 Demension Unit mm M Figure 1 6 Dimension of evaluation board According to conditions of soldering components the dimensions might be differed with the above figure Thus we recommend giving some extra spaces about 1 2 mm Z SOLLAE SYSTEMS 14 http www ezTCP com CSE M53 User s Manual Ver 2 0 2 Installation and Test 2 1 Installation Before testing CSE M53 users should connect both serial and Ethernet port to a PC It will be no problem that the Ethernet connection includes network hubs In this document whole processes are written assume that using it with evaluation board Figure 2 1 connection between CSE M53 and a PC Procedures for the test are followed 2 1 1 Setting Network Aera This step is for setting both CSE M53 and users PC to be located the same network If only they are the TCP connection between them can be established Setting of the PC Add or change the IP address of the network adapter on your PC like following Get into the menu of Windows Control Panel gt gt Network Connections gt gt Properties of the Network Adapter with right click of your mouse Then you can show the properties of Internet Protocol TCP IP In there press the Advan
21. de la sant humaine et de l environnement Pour plus d informations sur les lieux de collecte des quipements lectroniques usag s contacter votre mairie ou votre service local de traitement des d chets L SOLLAE SYSTEMS 61 http www ezTCP com CSE M53 User s Manual Ver 2 0 12 History 2009 12 01 14 The form of History has been changed Adding Author O Description of sc command has been changed O Description of debugging message has been changed Maximum value of Event byte has been added Some of hyperlinks have been removed Description of Sending MAC Address and RFC2217 option have been changed 2010 01 06 Some expressions including version have been modified Roy LEE 2010 03 22 Some figures and expressions have been modified Roy LEE 2010 04 06 the application circuit has been modified Roy LEE 2010 05 20 Description of RST pin has been added in the Table 1 2 Roy LEE 2010 06 25 Maximum value of the Event Bytes has been corrected Roy LEE 2011 03 24 17 Figures about ezManager have been updated A term has been replaced in UDP Event Byte gt Block Size The link of support page has been corrected Information about dimensions of EVB has been added 2012 06 28 19 Change the domain name to www ezTCP com Lisa Shin O Extend the warranty period to two years Remove description about PPPoE and DHCP 2013 05 15 2 0 O Add Exemption from Liability contents Lisa Shin
22. e SYSTEM UPTIME Amount of time is displayed since CSE M53 boots up IP4 NETWORK INFORMATION All information about related items with IP Address is shown here It works even if the IP address is assigned from DHCP or PPPoE L SOLLAE SYSTEMS 45 http www ezTCP com CSE M53 User s Manual Ver 2 0 TCP STATE TCP status of each port is shown this section Message Description LISTEN listening TCP connection CLOSE TCP connection is closed SYN_SENT Send SYN segment to make TCP connection ESTABLISHED When TCP connection is established N A In UDP mode Table 6 2 TCP STATE SERIAL STATUS Amount of data in every buffer is displayed The unit is byte Buffer Description SiO rx The number of data which is received from the COM port net tx The number of data which is sent to the remote host net rx The number of data which is received from the remote host sio tx The number of data which is sent to the COM port Table 6 3 SERIAL STATUS ARP TABLE This part shows ARP table on CSE M53 When TCP connection is established or UDP data communication is performed the information of IP and MAC address is automatically stored in the ARP table This information is held for 1 minute When 50 seconds is passed CSE M53 starts broadcasting the ARP packet again If there is no response until the time is 0 the information is removed If there is response the time is updat
23. ed 60 seconds again e TCP IP Connection In this section the same information with TCP STATE is displayed with IP address and port number A difference is that users can terminate TCP connection When right click on a session a small pop up window is created Password This text box is activated when CSE M53 has a password If users want to close TCP connection with right click of mouse on the session this password has to be correctly filled Refresh Every 1 Second If this option is checked ezManager send query in every second L SOLLAE SYSTEMS 46 http www ezTCP com CSE M53 User s Manual Ver 2 0 6 2 3 Debugging Message By using Debugging option users can receive debugging messages from CSE M53 on the network Setting debugging option Network Option serial Port Option v Telnet V IP Address Search Send MAC Address W Debugging Message ri SSL 5 C Lorie ct Lor p sen Comment Search All Write a JV Advanced Menu Change F W HTML Debugging Message Set Password Factory Reset Figure 6 9 setting debugging option D Check the Debugging Message option Q Press the Write button After check the Advanced Menu click the Debugging Message button And then the debugging message window is shown on your screen like figure 6 10 L SOLLAE SYSTEMS 47 http www ezTCP com CSE M53 User s Manual Ver 2 0 m Debugging Message lol x
24. eds for adding function or fixing bugs the firmware is modified and released We recommend that users keep use the latest released firmware 6 1 2 Processes Downloading the latest released firmware Download the newest firmware file We update our homepage when a new firmware is released You can find it on our website Entering ISP mode Enter ISP mode to download firmware file to CSE M53 Run a TFTP client and ready to send the F W file Run a TFTP client program ezManager is equipped the client program Click the Change F W HTML button Local IP Address C Firmwa Search All Write JW Advanced Ment QD Change F W HTML SOA Set Password Factory Reset Figure 6 1 running TFTP client Check the Advanced Menu check box D Click the Change F W HTML button to run TFTP client Select the Change Firmware radio button Input the IP address of CSE M53 to the Local IP Address text box Press the Open Firmware HTML button and choose the firmware file L SOLLAE SYSTEMS 41 http www ezTCP com CSE M53 User s Manual Ver 2 0 Checking firmware file and Sending Local IP Address Lol Change Firmware C ch 10 1 0 e A Open Firmware HTML M E 9 CRC 4F80 C Documents and Set Local IP Address Lol Change Firmwart C Change HTML TEMG 0800 on Ee CRC 4F80 C Documents and Settings mhyun Desktop MS3R104 BIN ezTCP Manag
25. eived Packet Notify IP Change Protocol Interval x o Minute s Port Data e 1476 e DDNS ID DDNS Password Host Name custom Status Simple Test Figure 3 1 initial appearance of ezManager 3 1 1 Configuration via LAN Checklists Make sure the connection between your PC and CSE M53 If they are the same network MAC Address search button can be used If they aren t only IP Address search is allowed to use Procedures 1 Searching Use Search All or Read button on ezManager 2 Selecting Select a MAC Address which you want to set parameters 3 Setting Set the values of the parameters properly Store the setting with Write button Figure 3 2 procedures for configuration via LAN L SOLLAE SYSTEMS 20 http www ezTCP com CSE M53 User s Manual Ver 2 0 3 1 2 Configuration via Serial Checklists Make sure the connection between your PC and CSE M53 using RS232 cross cable To use this CSE M53 has to be operating in the Serial Configuration mode By connecting ISP pin with GND LOW less than 1 second you can enter the mode After this read the setting via Serial tab on ezManager Procedures 1 Mode Switching Change the mode to Serial Configuration 2 Reading Read environmental parameters with Read button di 3 Setting Set the values of the parameters properly 4 Writing Store the settin
26. ends the data right after a connection is established 512 or under 512 or under bytes are strongly recommended Table 5 1 Event Byte Timeout If there is no transmission of data for amount of time which is set to this parameter CSE M53 tries to terminate established TCP connection Notify IP Change This function is for notifying information about changed IP address to a server Not only the TCP UDP protocol but Dynamic Domain Name Service DDNS can be used Restriction of Access Users can block TCP connections from unauthorized hosts by using this option Both IP and MAC address are available L SOLLAE SYSTEMS 26 http www ezTCP com CSE M53 User s Manual Ver 2 0 5 1 2 Examples A situation that Event Byte is set to 0 Figure 5 1 time chart for a situation that Event Byte is set to zero Points States CSE M53 is listening to connection requests Remote host has sent a connection request SYN segment Processes of the connection The connection has been established Data communication on both sides Table 5 2 states of each points Look at the blue arrow The data 123 from the serial port had sent before the connection is established In this case the data wasn t sent because of the Event Byte is set to 0 Z SOLLAE SYSTEMS 27 http www ezTCP com CSE M53 User s Manual Ver 2 0 A situation that Event Byte is set to
27. er L SOLLAE SYSTEMS 16 http www ezTCP com CSE M53 User s Manual Ver 2 0 2 2 Simple Test If you press the Simple Test button test program will be shown on your screen Connecting to the CSE M53 via LAN M Simple Test x LAN Receive 30 31 32 33 34 35 36 37 101234567 a zd z Data Length fe a Apply Received Data 0 Byte s Save Load Send Data Peer Address Peer Port 10 1 0 1 1470 2 Figure 2 3 settings for TCP connection D Select TCP Client Input correct IP address and port number of CSE M53 Clink the Connect button In case of TCP Server it will be Listen button Opening RS232 Port RS232 Send Receive 30 31 32 33 34 35 36 37 101234567 u mms PO mr Save Load pauarate Parity Data Bits Stop Bit Flow Contro com 19200 e NONE fe Dip DI ONE e Figure 2 4 opening COM Port Select COM port which the CSE M53 is connected to Make sure that all the parameters are the same with CSE M53 Press the Open button Z SOLLAE SYSTEMS 17 http www ezTCP com CSE M53 User s Manual Ver 2 0 Confirm the TCP Connection and COM port status M Simple Test 30 31 32 33 34 35 36 37 01234567 Figure 2 5 TCP Connected message Check the message if the TCP connection is established 30 31 32 33 34 35 36 37 01234567 Figure 2 6 COM Port open message Check the message if the COM port
28. er 3 0H 2010 03 03 ES LA W Downloading firmware has been successfully completed Figure 6 2 sending firmware file D Check if the name and path of the firmware file are correct Click the Send button Confirm the completed message Z SOLLAE SYSTEMS 42 http www ezTCP com CSE M53 User s Manual Ver 2 0 6 2 Status Monitoring 6 2 1 Using TELNET Once the TELNET option is activated users can remotely log in to CSE M53 If a password is set users should input the password After then messages from CSE M53 appear like the below figure CSE M53 Management Console v1 04 Sol lae Systems Iso Figure 6 3 log in to CSE M53 on TELNET Followed commands let users check each state Command Option Description Usage net Network Status Ish st net Sio Serial Port Status Ish st sio uptime System Uptime Ish gt st uptime op1 op2 Session Control Ish gt sc com1 close Table 6 1 Commands for checking states st net st net command displays present network states of all sessions sh gt st net proto name local address peer address senda state tty 10 1 0 1 23 10 16 0 56 2391 219 ESTABLISHED 10 1 0 1 1470 10 16 0 56 2395 0 ESTABLISHED i Figure 6 4 st net command L SOLLAE SYSTEMS 43 http www ezTCP com CSE M53 User s Manual Ver 2 0 st sio st sio command displays the number of bytes for the serial port Ish gt st sio
29. g with Write button Figure 3 3 procedures for configuration via Serial Step 2 Reading r Search ezTCP mac Im pO Search ezTCP mac IP Serial o ss Read Reboot Figure 3 4 reading procedure via serial Q Choose the Serial tab Select the COM port which the CSE M53 is connected with Open the COM port with the Open button Load the setting with Read button If you want to know more specific manners of setting please refer to the document ezManager Users Manual on the Download gt gt Technical Document of our website L SOLLAE SYSTEMS 21 http www ezTCP com CSE M53 User s Manual Ver 2 0 3 2 AT command In the AT command mode you can change some parameters through the serial port Checklists Make sure the connection between your PC and CSE M53 using RS232 cross cable To use this CSE M53 has to be set to AT command mode as its communication mode This can be configured by ezManager TCP IP Communication Mode ATC AT Command M Peer Address Peer Port 0 Local Port 1470 F TCP Server Figure 3 5 setting the communication mode to the AT command Procedures 1 Mode Configuration Set the communication mode to the AT commands 2 Opening Terminal Run a serial terminal program like HyperTerminal 3 Setting Set the values properly with the AT commands Store the setting with the A
30. had been 5 bytes Even though those are come before the connection is established the data 123 45 and 67 are transmitted to the remote host because of the Event Byte is set to 5 Z SOLLAE SYSTEMS 32 http www ezTCP com CSE M53 User s Manual Ver 2 0 An activated TCP Server option Points Figure 5 6 time chart for activating TCP Server option States CSE M53 is listening to connection requests The connection has been established CSE M53 is on line and processes of the disconnection The connection has been terminated Both sides are offline Sends TCP connection request segment Table 5 9 states of each points The TCP Server Client mode can be useful option by using Event Byte and Timeout Note that only one TCP connection can be established at the same time so users should consider setting Timeout properly Z SOLLAE SYSTEMS 33 http www ezTCP com CSE M53 User s Manual Ver 2 0 5 3 AT Command AT command is a mode which users control CSE M53 with AT command like controlling modem In this mode active and passive TCP connections are available And users are allowed to configure some environmental parameters with extended command s 5 3 1 Key parameters The configuration should be implemented via the serial port of CSE M53 Commands Description Examples PLIP Local IP Address AT PLIP 10 1 0 1 lt CR gt
31. has been opened L SOLLAE SYSTEMS 18 http www ezTCP com CSE M53 User s Manual Ver 2 0 Data transmission test M Simple Test 30 31 32 33 34 35 36 37 101234567 Client Local Port Peer Address Peer Port Connect E Keep Alive IE 10 21 01 i476 Disconnect cted 10 1 0 1 1470 RS232 Send 30 31 32 33 34 35 36 37 101234567 J s0 31 32 33 34 35 36 37 101234567 Data Length fe zl m Received Data 0 Byte s Save Clear COM Port Baudrate Parity Data Bits Stop Bit Flow Control com The COM port has opened Figure 2 7 successful data transmission 9 Click the Send data on the LAN part Check the data have been shown from the step Figure 2 8 LAN RS232 Press the Send data on the RS232 part Check the data have been received from the step Figure 2 9 RS232 LAN Z SOLLAE SYSTEMS 19 http www ezTCP com CSE M53 User s Manual Ver 2 0 3 Configuration 3 1 Configuration with ezManager Wi ezTCP Manager v3 1G 2011 03 14 FES CP Network option Serial Port mc p seriar Product SI MAC Address Network Joo zo es oo Joo ox Local IP Address Read DE Use statie IP address Obtain an IP Automatically DHCP Search Results Ds bede Obtain an IP Eutomatically PPPoE PPPoE ID PPPoE Password Gateway IP 7 Obtain DNS Server Address Automatically WEP REE E obtain an IP From The First Rec
32. he ISP pin is basically pulled up it keeps HIGH as long as you don t input 0 volt LOW L SOLLAE SYSTEMS 23 http www ezTCP com CSE M53 User s Manual Ver 2 0 4 3 Comparison with each mode Table 4 1 shows summaries of each mode Supplying the power when the status of ISP pin Normal HIGH changeable is Serial Giving LOW to the ISP pin between 10ms and 1s 115200 N 8 1 Configuration Supplying the power when the status of ISP pin ISP de p P 115200 N 8 1 is LOW Giving LOW to the pin over 1s Table 4 1 Comparison with each mode 4 4 Normal Mode In normal mode there are four connection types to communication with a remote host TCP Server TCP Client AT Command Modifying Serial Name Protocol Connection software of Topology configuration serial devices Required Available L 4 2 Comparison four communication modes AT me TCP is a type of protocol which has a process of connection The connection has to be one to one The part who tries to make the connection is called TCP Client and the other part is TCP Server On the other hand UDP has no connection process Because of this each of them can be send and receive data from multiple hosts L SOLLAE SYSTEMS 24 http www ezTCP com CSE M53 User s Manual Ver 2 0 4 5 Serial Configuration Mode This is a mode for setting environmental parameters through RS232 port If you can t use the Ethernet
33. host is listening and works correctly the connection will be established After then CSE M53 converts the raw data from the serial port to TCP IP data and sends them to the network and vice versa 5 2 1 Key parameters Peer Address This item should be an address of a remote host who is listening TCP connections Peer Port Peer Port should be the port number which is designated by the remote host Event Byte CSE M53 decides the time to send the connection request frame with this parameter Description Right after CSE M53 boots up right after the bytes set to Event Byte have been received from Otherwise the serial port 512 or under Setting to less than 512 bytes is strongly recommended Table 5 5 the operation of Event Byte 1 In addition users can handle the serial data before a TCP connection is established with this parameter Value Description 0 CSE M53 doesn t send the data Otherwise CSE M53 sends the data right after a connection is established 512 or under Setting to less than 512 bytes is strongly recommended Table 5 6 the operation of Event Byte 2 Timeout If there is no transmission of data for amount of time which is set to this parameter CSE M53 tries to terminate established TCP connection TCP Server This check option is enable the TCP server client mode In this mode CSE M53 can be operated as a TCP server or client without changing its
34. i Serial Port RS232 115200 NONE 8 1 NONE Figure 6 10 debugging message window D Network Adapter Place for listing received debugging messages from CSE M53 over the network Auto update to display the latest captured file on the screen of MAC Address and Serial port Information of a selected message Amount of received or dropped data and XON OFF signals 6 Serial port s receiving status with LED interface D Place for listing received data from the serial port Buttons for saving closing and clearing a log file including an auto scroll option Serial port s transmitting status with LED interface Place for listing sent data to the serial port Buttons for saving closing and clearing a log file including an auto scroll option To start capturing debugging messages from CSE M53 To stop capturing debugging messages from CSE M53 L SOLLAE SYSTEMS 48 http www ezTCP com CSE M53 User s Manual Ver 2 0 Reboot button is for software rebooting Load Message is for loading a debugging log file to display Closing debugging message window If you have problems with communication or connection it can be helpful for us that you capture the debugging messages and send us to the file When you use Debugging Message function it can cause network traffic because the messages are broadcasted to whole network If you don t use it anymore you should uncheck the function L SO
35. is situation check the network status by connecting on TELNET or using ezManager L SOLLAE SYSTEMS 54 http www ezTCP com CSE M53 User s Manual Ver 2 0 8 3 Data Communication Problem on the Serial Connection of Pins Check if the connection of each pin is right Using cables users choose the right type of cable which is suitable for the device Transmit Data TXD pin should be connected with Receive Data RXD pin Look at the figure 8 1 Figure 8 1 RS232 connection Setting parameters Check if all the serial port parameters like Baud Rate Data bit Stop bit and Parity are properly set Contact us if you have any questions about above steps or our products Z SOLLAE SYSTEMS 55 http www ezTCP com CSE M53 User s Manual Ver 2 0 9 Related Material 9 1 Technical Documents You can find the technical documents at our website DataSheet IP Change Notification DDNS Sending MAC Address function TCP Server Client mode Telnet COM Port Control Option etc 9 2 Smart phone Application ezManager IOS ezManager Android TCP IP Client Android L SOLLAE SYSTEMS 56 http www ezTCP com CSE M53 User s Manual Ver 2 0 10 Technical Support and Warranty 10 1 Technical Support If you have any question regarding operation of the product visit Customer Support FAQ corner and the message board on Sollae Systems web site or se
36. mask gateway IP address and DNS IP address should be configured TCP Server side TCP Client side Local IP Address Local Port Subnet Local IP Address Peer Address Peer Port Mask Gateway IP Address DNS IP Subnet Mask Gateway IP Address DNS IP Address DDNS option Address Table 8 1 major parameters related with TCP IP PING Test Confirm the connection over the network by PING test If the CSE M53 doesn t send any reply from the request check the network environment e Firewall In case the networks which need strong security the access may be denied by their firewall Under this circumstance users should ask the person in charge of their network to release ports which will be used Ex TCP 1470 UDP 50005 Operation Mode TCP connection is not possible when CSE M53 is operating in the ISP or Serial Configuration mode Communication Mode To make TCP connection both a server and client should exist If there are only servers or clients TCP connection can t be established ezICP Firewall When users set the ezTCP firewall with MAC and IP address any hosts can t be reachable to it except for the hosts which have the allowed MAC and IP address Inactivate the option or check the setting is correct Checking the TCP status TCP is a protocol connected one to one without multiple connection function Because of this if a device is on TCP connection other requests are denied If users are in th
37. ment sssssssssssssssssssssssssssnesssssnessssnnessasenstssnssncsasen sanesoseoasssstsses 41 6 1 Wpgradidi BlMWare sassen terende EE 41 DIT FIWE eere RE de EA E E EEEE EENEN 41 DN EN OT LR 41 6 2 Stats Mentoring M 43 62 1 Using TELNET armand 43 6 22 Using ezManager EEN 45 623 Debugging Message ERROR dre 47 7 Additional FUNCtIONS svicsiccesescccsssecescsssccssevacenscscscocsiensiocstecasenssteosansizesasccesnsesesducosenasevazerstantes 50 LA SECUN 50 7 1 1 Restriction of Access ezTCP Firewall cecceccsessvesssesssesssesssesssesssssssesssesssisssisssissssssissssssissssssessnesens 50 PAZ Setting PASS EE 50 122 NO IP CAN ed eee 51 T3 Sending MAC Address ci decedere elegiae tele reb berto teste 52 7 4 TELNET COM port Control Option RFC 2217 nn 52 8 Self Test in Trouble eegener ee eege eegen 53 8 1 Searching problem with ezManager 53 8 2 Connection Problem over TCP IP rennes 54 8 3 Data Communication Problem on the Serial 55 9 Related Material it eer rRos 56 L SOLLAE SYSTEMS 3 http www ezTCP com CSE M53 User s Manual Ver 2 0 93 Technical DOCUMENTS a er ts 56 9 2 Smart phone Application 56 10 Technical Support and Warranty ss 57 10 1 Technical Supports anssen tete naaa 57 EE l
38. n Trouble When users are in trouble with CSE M53 make sure all the followed steps first 8 1 Searching problem with ezManager Confirming types of configuration utility CSE M53 can be configured by ezManager Stopping Firewall operation Firewalls of personal computer or network block broadcast packets Stop all the firewalls before searching CSE M53 Most of vaccine programs have firewall functions so it can cause some trouble to search CSE M53 Stop these programs before the searching Stable supply of the power Check if the power is supplied continually If the power is constantly supplied the LED on the CSE M53 s body blinks slowly Connection with the network Make sure that the network connection is fine including Ethernet cable In this step we recommend that users connect CSE M53 with PC directly or in the same network hub Checking options of restriction In case that restriction of access is activated the communication with ezManager can be impossible When users are in this situation make CSE M53 operate in ISP mode L SOLLAE SYSTEMS 53 http www ezTCP com CSE M53 User s Manual Ver 2 0 8 2 Connection Problem over TCP IP Checking parameters related with TCP IP When CSE M53 has a private network IP address personal computer s IP address has to be the same sub network Check if the IP address and local port number are correct In case of a fixed IP address the subnet
39. nd us an email at the following address E mail support eztcp com Website Address for Customer Support http www eztcp com en support 10 2 Warranty 10 2 1 Refund Upon the customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 10 2 2 Free Repair Services For product failures occurring within two years after purchase Sollae Systems provides free repair services or exchange the product However if the product failure is due to user s fault repair service fees will be charged or the product will be replaced at user s expense 10 2 3 Charged Repair Services For product failures occurring after the warranty period two years or resulting from user s fault repair service fees will be charged and the product will be replaced at user s expense L SOLLAE SYSTEMS 57 http www ezTCP com CSE M53 User s Manual Ver 2 0 11 Precaution and Exemption from Liability 11 1 Precaution Sollae Systems is not responsible for product failures occurring due to user s alternation of the product Specifications of the product are subject to change without prior notice for performance improvement Sollae Systems does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications Reverse engineering of firmware and applications provided by Sollae Systems is prohibite
40. ows Major ezManager Supports Downloading F W Utilities Serial to TCP IP Virtual driver for MS Windows Table 1 2 Software specification In RS 485 communication or Using Xon Xoff flow control option the maximum baud rate is restricted to 230 400 bps L SOLLAE SYSTEMS 8 http www ezTCP com CSE M53 User s Manual Ver 2 0 1 5 3 Demension The dimension of CSE M53 is followed Unit mm 0000000000 Di o o o o o a o CSE M53 Dimension Unit mm Figure 1 5 dimensions of CSE M53 Z SOLLAE SYSTEMS 9 http www ezTCP com CSE M53 User s Manual Ver 2 0 1 5 4 Pins JP1 JP2 Connector JP1 and JP2 have headers of 2mm pitch There is a circle by the first pin pin number 1 of JP1 D o Table 1 3 JP1 VDD 33V DC 3 3V volt power Voo NEUE System Reset Low Active rc 5 TPN En ES L9 20 10 RST Valid time for giving Low signal Input duration over 1ms is recommended ae d UART RTS Request To Send Low TXDE in RS485 Sending data High Table 1 4 JP2 GND RXD TXD CTS cs sis un 10 ce N mt BR amp w N n L SOLLAE SYSTEMS 10 http www ezTCP com CSE M53 User s Manual Ver 2 0 1 5 5 Voltage Features Parameters Description Minimum Maximum Supplied Voltage 3 0 3 6 High level input voltage 2 0 5 0 Low level input voltage 0 3 1 3 High level outpu
41. setting L SOLLAE SYSTEMS 30 http www ezTCP com CSE M53 User s Manual Ver 2 0 DNS IP Address DNS IP Address needs when users use host name instead of the IP address 5 2 2 Examples A situation that Event Byte is set to 0 Points Figure 5 4 time chart for a situation that Event Byte is set to 0 States Before the power is supplied Sends TCP connection request segment right after it boots up Processes of the disconnection The connection has been established Look at the blue arrow The data 123 from the serial port had sent before the connection is established In this case the data wasn t sent because of the Event Byte is set to 0 Z SOLLAE SYSTEMS Data communication on both sides Table 5 7 states of each points 31 http www ezTCP com CSE M53 User s Manual Ver 2 0 A situation that Event Byte is set to 5 i 0000 0000 6666 Figure 5 5 time chart for a situation that Event Byte is set to 5 Points States CSE M53 has receives data from its serial port until the amount of data is 5 bytes Sends connection request segment right after receiving 5 bytes Processes of the TCP connection The connection has been established The 1234567 is transmitted to the remote host Table 5 8 states of each points As you can see in the figure 5 5 CSE M53 sends request segment right after the serial data
42. t Table 5 11 states of each points Most of the response messages from the serial port of CSE M53 are omitted on above figure Z SOLLAE SYSTEMS 35 http www ezTCP com CSE M53 User s Manual Ver 2 0 TCP Client setting parameters and active connection Points Figure 5 8 TCP Active connection States Set parameters in the AT command mode CSE M53 sends a TCP connection request with the ATD command Processes of TCP connection TCP connection has been established Z SOLLAE SYSTEMS CSE M53 sends CONNECT message to the serial port Table 5 12 states of each points 36 http www ezTCP com CSE M53 User s Manual Ver 2 0 Termination of online status entering the AT command mode Figure 5 9 Termination of online status States Keeps TCP connection CSE M53 enters the AT command mode with receiving Keeps AC command mode CSE M53 terminates TCP connection with ATH command Processes of TCP disconnection TCP connection has been terminated CSE M53 sends NO CARRIER with disconnection Table 5 13 states of each points CSE M53 changes the mode to AT command when receiving and sending OK message In this state the communication with remote host is not possible because CSE M53 processes only AT command Whenever you want to go back to online state TCP connection use ATO
43. t voltage 24 Low level output voltage Table 1 5 voltage features 1 5 6 An Application Circuit LED_A L1 TD R1 LED_A L2 TD R2 LED B L3 RD R7 LED_B L4 RD R8 CT R3 TOpF K 1 4 HopF K 2 2 C3 A o 2 CH GNDA HAIC R4 NC R6 RDA 126BAG1A UDE Corp s RJ45 w Pulse Transformer BST FROM meus PIO SP FROM MCU PIO Ho gt gt TO MCU S PIO SIGNAL INTERFACE BETWEEN USER S MCU C5l HOpF K RXD LED o0 J O O1 RON 0 100 Go No o CSE M53 2 TXD LED LINK LED STS LED 2 D VDD_3 3V 2 2 LED INTERFACE Fig 1 1 an Application Circuit L SOLLAE SYSTEMS idc http www ezTCP com CSE M53 User s Manual Ver 2 0 1 6 Evaluation Board Evaluation board for CSE M53 is equipped a RS45 connector and a D SUB 9 pin Male connector including the 5V DC power connector BS M7 ife NU ud O LADTRI C3 Fig 1 2 EVB for CSE M53 1 6 1 Parts Power Control Jumper To control supplying the power to the EVB or not Division V Connection Disconnection Fig 1 3 power control jumper Q DC Power Connector Terminal for connecting DC 5V Power RJ45 Connector Terminal for connecting UTP cable for Ethernet D SUB 9 Male Connector Terminal for connecting 9 pin D SUB connecter for RS 232 JP5 Only used at the Factory
44. this mode is only way to configure the values Once entering this mode use the Read button on the Serial tab of ezManager Figure 3 4 4 6 ISP Mode You can enter this mode by pressing the ISP button over 1 second There are two special purposes in this mode 4 6 1 Upgrading Firmware ISP mode is for upgrading firmware which is offered by us The upgrade is implemented on Ethernet The details are followed in the 6 1 Upgrading Firmware 4 6 2 Revoking Serurity Options CSE M53 offers restriction methods for security like filtering password or MAC and IP address In the ISP mode you can revoke all of these When you forgot the password enter the ISP mode to solve the problem L SOLLAE SYSTEMS 25 http www ezTCP com CSE M53 User s Manual Ver 2 0 5 Communication Modes 5 1 TCP Server In this mode CSE M53 functions as a TCP server CSE M53 listens to a TCP connection from remote host Once a host tries to connect to CSE M53 it responses that request After the connection is established CSE M53 converts the raw data from the serial port to TCP IP data and sends them to the network and vice versa 5 1 1 Key parameters local Port This is a server s port number which is used in the TCP connection Event Byte With setting event bytes users can handle the serial data before a TCP connection is established Value Description 0 CSE M53 doesn t send the data Otherwise CSE M53 s
45. tie se limitera exclusivement selon le choix de Sollae Systems Co Ltd et de ses distributeurs au remboursement de votre produit ou de sa r paration ou de son change Sollae Systems Co Ltd et ses distributeurs d mentent toutes autres garanties exprim es ou implicites Tous les CSE M53 sont test s avant exp dition Toute utilisation en dehors des sp cifications et limites indiqu es dans cette documentation ainsi que les court circuit les chocs les utilisations non autoris es pourront affecter la fiabilit cr er des dysfonctionnements et ou la destruction du CSE M53 sans que la responsabilit de Sollae Systems Co Ltd et de ses distributeurs ne puissent tre mise en cause ni que le CSE M53 puisse tre chang au titre de la garantie Rappel sur l vacuation des quipements lectroniques usag s Le symbole de la poubelle barr pr sent sur le CSE M53 indique que vous ne pouvez pas vous d barrasser de ce dernier de la m me facon que vos d chets courants Au contraire vous tes responsable de l vacuation du CSE M53 lorsqu il arrive en fin de vie ou qu il est hors d usage et cet effet vous tes tenu de le remettre un point de collecte agr pour le recyclage des quipements lectriques et lectroniques usag s Le tri l vacuation et le recyclage s par s de vos quipements usag s permettent de pr server les ressources naturelles et de s assurer que ces quipements sont recycl s dans le respect
46. u E 57 JOS TREND nennen 57 1022 Free Repair Services ttt tentent ettet teeth tenta 57 10 23 Charged Repair Services rennes 57 11 Precaution and Exemption from Liability sn 58 DN Ee LE 58 11 2 Exemption from Liability mn 59 ILZI English VEION arare prar RU ER UMEN UR et rds 59 11 22 French version res 60 125 Dele 62 L SOLLAE SYSTEMS 4 http www ezTCP com CSE M53 User s Manual Ver 2 0 1 Overview 1 1 Overview Almost all communication devices including PC are using serial transmission In this type devices send and receive data in the order of each byte The serial communication is quite simple to implement but has weaknesses like short distance and hard maintenance CSE M53 lets the serial devices connect to the Internet To communicate on the Internet devices should use TCP IP protocol so CSE M53 processes the converting serial data to TCP IP 1 2 Main Features Very compact module type 20mm x 24mm High speed UART x 1 3 3V TTL available on RS232 RS422 RS485 extension Industrial temperature range 40 C 85 C L SOLLAE SYSTEMS 5 http www ezTCP com CSE M53 User s Manual Ver 2 0 1 3 Application Examples 1 1 Connection with a PC Serial Device Figure 1 1 1 1 connection with a PC Applied to LANs A Serial Device Figure 1 2 applied to LANs Z SOLLAE SYSTEMS 6 http www ezTCP

Download Pdf Manuals

image

Related Search

Related Contents

Tabla de contenido  Manual de Instalación  エコキュート  BVW-652 - Boretti  XSB (prolog) Manual part 1  SikaRep final - Sika Ecuatoriana  

Copyright © All rights reserved.
Failed to retrieve file