Home

Is hear - Explona

image

Contents

1. value without dot e voltage u at the end e time hour and minute with blinking dot between without seconds e stop watch readings with seconds 2 2 Operation All functions of explona dakar are accessible from keyboard or wired remote controller Remote controller allows to use most frequent functions reset freeze measurement and stop watch Remote controller wiring allows to install connector in any place Any number of external reset switches can be connected explona dakar 2007 f1 02 User manual version 1 teOUNSGY www explona com 2 3 Zeroing the distance explona dakar has two distance counters e long odo reset by long press of the red button on the keyboard short trip reset by pressing shortly o red button enter on the keyboard if short distance wasn t shown it will be recalled on the left display untouched second press will reset o red button on the remote o external reset switch if connected 2 4 The odo adjustment Sometimes it happens that tripmeter readings differ from a roadbook eq after a mistake turn Odo adjustment is necessary to change value so it is correct again To adjust the long distance press ADJ If the long distance wasn t shown on display it will be recalled on the left field The last digit of a value will blink Pressing up or down change value The corrected value can be accepted in two ways e pressing ADJ again new value is ente
2. can be set manually using up and down keys This manual mode is helpful also to make small adjustments if previous value gives constant over understated results Calibration procedure 1 enter the configuration mode cp 3 select Cal menu press ADJ or Enter key to enter mode of changing value the right display will blink use up and down keys to set appropriate value of K press ADJ or Enter key to confirm the change ON oe ei select Accept menu and press Enter key During manual correction lower display shows present speed SoG This way a calibration using 1 on board GPS receiver can be performed adjust calibration such that both speed reading are identical The greater speed during such calibration the more accurate process is 4 Installation The device must be installed in a safe way It should not endanger health of driver and passenger during both regular work and accident In particular it mustn t obstruct the airbags o The installation can be performed in an authorized garage Current list of authorized garages is available on the website www explona com explona dakar 2007 f1 02 User manual version 1 teOUNSGY www explona com 4 1 Contents of the set The set contains of explona dakar electrical wiring remote controller remote controller wiring user manual and warranty card certificate of conformance with Dakar 2007 technical regulations TX10 driver to adjust the faste
3. the time zone it is recommended to implement daylight saving time using time zones explona dakar 2007 f1 02 User manual version 1 teONDGY www explona com 2 7 The stop function The stop function allows to freeze distance measurements It is indicated by showing Stop on the distance readings The stop function is enabled and disabled by e yellow button on the remote controller e simultaneous pressing F and ADJ 2 8 Change of the brightness Keys up and down change brightness of the display Decreasing the brightness below the minimum level tums off the display It is indicated by showing only dots on the display All measures are continued but the keyboard is inactive to prevent accidental changes The up key turns the display on 3 Configuration mode Entering the configuration mode e turn off and turn on the explona dakar e hold enter key while the serial number is displayed e the configuration menu will appear Blinking display shows an item which can be changed with up and down keys ADJ or Enter key switch between changing of the reading left display blinks and changing of the value right display blinks Configuration mode allows to set the following parameters e Cal calibration constant K cp 3 1 e Hour time e zone time zone from GMT 12 to GMT 12 in most of the Europe summer time is GMT 2 and winter time is GMT 1 e Accept pressing E
4. complished with the use of voltmeter When the ignition switch is turned on and car is moving the voltage on speed signal should vary periodically e g 0 i 12V or 0 i 5V If reed switch sensor is used one of its contacts should be connected to the SPEED wire and the explona dakar 2007 f1 02 User manual version 1 teONSGY www explona com other to the ground If inductance sensor is used it must be powered from vehicle and signal output should be connected to the SPEED wire The calibration should be performed after installation of the device o 5 Troubleshooting explona has a blank The display is turned off press and hold the up key it should become display brighter The power is not connected check the device wiring Cal Err blinks on the The device is not calibrated The measurements has no meaning Do the display calibration cp 3 1 Does explona work Ingress protection IP65 informs that device is protected from water jets under water but it doesn t mean the device can be placed under water for a prolonged time How can I tell if device Each conforming device has a certificate of conformance supplied with conforms to the Dakar the set Additionally during power up small letter d is shown near the 2007 specifications firmware version explona dakar 2007 f1 02 User manual version 1 teOUNSGY www explona com Brown ground EZI Yellow pow
5. er supply Green speed pulses White remote PE TTE TATA Schematic of explona dakar 2007 connections DOK 0 speed pulses connection External reset 5A fuse Ignition switch explona dakar 2007 f1 02 User manual version 1 HUNDS www explona com 6 Technical data External dimensions mm enclosure 160x82x32 with fastenings 195x97x40 Enclosure aluminum black Ingress protection IP65 dust tight protected from water jets Display 3 red LED display with 7 brightness steps can be turned off anti reflex coating Weight 710g Operating voltage 10 40V DC Power consumption max 5W Temperature range 20 70 C Partial distance resolution 10m Total distance resolution 10m or 100m 7 Rating plate TOIPOTO ANEAN explona g No user serviceable components inside Made in EU Poland www explona com We reserve the right to change specifications without prior notice The disposed device mustn t be DC 10 40V placed as an unsorted municipal MAX 5W waste it must be collected C separately ONN All trademarks are the property of the respective owners and are used for information purpose only Copyright by explona Devel Team explona dakar 2007 f1 02 User manual version 1
6. explona WeOUNDGY www explona com explona dakar 2007 User manual explona dakar 2007 is an intuitive to use advanced tripmeter It conforms to the Dakar 2007 technical regulations The regulations are available on the organizer s website http www dakar com 2007 DAK presentation docs reglement_auto_camion_us pdf Appropriate certificate is supplied with the device Its aluminum enclosure is waterproof and protects against various environment conditions In every light condition the readings are clear thanks to big LED display with brightness regulation The display can be turned off if needed The device has a quick recall of the distance reading from every other display mode It is fully configurable according to the needs of user Apart from time and stop watch reading all other readings can be shown on any of three displays Adjustable odo distance aids in navigation during professional rallies Basic modes of operation are possible from the wired remote controller unit There can be any number of external reset switches connected IteONSGY www explona com You should calibrate the device cp 3 1 after installation and each change of tyres Imprecise measurements can occur otherwise The device is supplied not calibrated which is shown by blinking Cal Err on display 1 Features of explona dakar 2007 e Two independent distance counters partial trip and total odo Maximum values are 999 9 and 9999 9 respec
7. nings set of stickers SO GO SID Ce ee S a box 4 2 Mechanical installation The device should be permanently attached It shouldn t restrict the field of view The enclosure is equipped with four fastenings The TX10 driver included should be used if the fastenings need to be adjusted or repositioned Be careful not to unscrew both fastenings from one side simultaneously It may compromise the leak proof All fastenings should be tighten after mount explona is specifically sealed to be leak proof e Opening of the device breaks the seal and voids warranty 4 3 Electrical installation Power supply should be protected with a 3A to 5A fuse The wiring should be connected according to the drawing on the last page Wire connections e brown GND ground e yellow 12V power supply after ignition dedicated switch explona doesn t have its own switch e green SPEED speed impulses Two pin connector is used for remote controller Additional external reset switches can be connected parallel to the remote controller see the schematics Three pin connector is used for connecting explona dakar 2007 to the installation 4 3 1 Connection of the speed signal explona dakar can be directly connected to vehicles equipped with electrical speedometer reed switch sensor or NPN NO inductance sensor If vehicle has an electrical speedometer vehicle speed signal VSS from car s wiring should be found It can be ac
8. nter key stores the settings and leaves the configuration mode 3 1 Calibration Calibration is the process of determining the number of pulses per 1 km or 1 mile of the travelled distance This is necessary to accurately measure the distance Calibration should be performed after installation and after each change of tyres The device is supplied not calibrated which is show by blinking Cal Err on display The calibration constant K should be in range 400 65535 3 1 1 Calibration using a reference section of road The length of the section should be 1km or Imile depending on the choice of units The more precise section will result in more precise tripmeter measurements The selected section of road can be e reference section of measuring authorities explona dakar 2007 f1 02 User manual version 1 teOUNSGY www explona com e distance between road markers e measured by correctly calibrated other tripmeter e measuring tape although lot of patience is required Calibration procedure 1 enter the configuration mode cp 3 select Cal menu position your car at the beginning of the section 2 3 4 press F key 5 drive entire section stop exactly at the end 6 press and hold enter key until Cal menu appears 7 select Accept menu and press enter key 3 1 2 Manual correction of the calibration If calibration constant K is known e g it was determined previously for give set of wheels and car it
9. red e pressing enter new value of a long distance is entered and short distance trip is simultaneously reset 2 5 Change of the displayed value The F key changes the display configuration Pressing this key allows to change value on bottom left right display The description of selected value will blink if being changed Keys up and down change the value The value is accepted by pressing F or after a while of idle If explona is in odo adjustment mode the change of display configuration won t be possible 2 6 The stop watch The device is equipped with 24h stop watch It can count time even without a power supply Stop watch can be operated only when it is shown on the bottom display In order to show stop watch press F key bottom display will start blinking and set description Stoper using key up or down Stop watch operation e from the keyboard press F key to make the bottom display blink As long as the bottom display blinks it can be operated with enter key e from the remote controller using black key Stop watch works in the usual manner pressing the keys shortly starts and stops counting of the time Longer press zeroes the stop watch Change of the time while a stop watch is running will change stop watch readings If change of 1 the time is necessary the stop watch should be stopped then time changed and finally stop watch restarted Stop watch is not affected by change of
10. tively After that a roll over to 0 is made e Quick recall of both partial trip and total odo distance e Adjustable odo distance e Speed measurement with 1km h mph resolution e Battery backed 24h clock e Stop watch of 1 second resolution It counts independently of the voltage supply Maximum reading is 23 59 59 after which roll over to 0 00 00 occurs counting is not stopped e Battery voltage measure Resolution of 0 1 V e Stop function freezes distance measurement Other features e Wired remote controller for basic operations e Any number of external reset switches e Non volatile memory e Easily distinguishable readings e Fully configurable displays e Three big LED displays 7 steps of brightness ability to turn the display off e Anti reflex coating ingress protection IP 65 e Easy mount thanks to universal fasting 2 Operation of the explona dakar 2007 2 1 Readings On each of the three LED displays the following readings can be shown e trip short partial distance e odo long total distance e SoG speed speed over ground e Accu battery voltage Additionally readings which can be shown on the bottom display e Hour present time e Stoper stop watch explona dakar 2007 f1 02 User manual version 1 gt www explona com In order to identify quickly the readings the following distinction was made e distance value with a dot e speed