Home
Open DataSheet in a new window.
Contents
1. SNMP Accessories ENVIROSENSE Monitors temperature humidity and contact closure inputs Requires 1 SNMPWEBCARD or switched PDU SNMP Accessories SRSWITCH Magnetic Door Switch Kit for front and rear doors requires 1 ENVIROSENSE More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 4860 Copyright 2011 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
2. e 1U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets e OU vertical wall mount and under counter mounting is supported in many applications e Circuit breaker free format prevents power interruptions due to tripped breakers while still providing mains panel protection from overloads and short circuit fault conditions Specifications OVERVIEW Model Type Switched PDU Type Switched OUTPUT Frequency 50 60 Hz compatibility Output nominal voltage 120V Outlet quantity type 16 NEMA 5 15R Customized load 16 individually controlled outlets management receptacles INPUT PDU Input Voltage 100 120 127 Recommended 120V Electrical Service Maximum Input Amps 15 A Input connection type NEMA 5 15P PDU Plug Type NEMA 5 15P Input cord length ft 12 Voltage compatibility 120 VAC Phase Single Phase LEDS ALARMS amp SWITCHES Front panel LEDs 16 LEDs display power on off status for each outlet Digital Current Meter display shows total output power consumption in amps PHYSICAL Shipping weight Ibs 16 Shipping weight kg 13 Unit Dimensions 1 75 1U x 17 5 x 15 5 HWD in Unit Dimensions 4 44 x 44 4 x 39 4 HWD cm Shipping Dimensions 5 5 x 23 5 x 21 5 HWD in Shipping Dimensions 14 x 59 7 x 54 6 HWD cm Unit weight Ibs 12 5 Unit weight kg 57 Material of Steel construction Style Rackmount Form factors 1U rackmount supported PDU Form Fa
3. networked managed PDU to remotely reboot individually locked up devices such a network switches hubs servers etc Package Includes e PDU with attached 5 15P input power cord e Installable 1U mounting brackets e PowerAlert software e User manual Features e 120V 15A maximum capacity agency de rated to 12 amps Switched Metered and Monitored Power Distribution Unit PDU with built in web network interface in 1U horizontal rack form factor e Includes attached 5 15P input plug and 16 5 15R controllable outlets 8 front 8 rear e Supports individually controllable output receptacles current metering network monitoring and remote control via built in web network monitoring and control card e Offers the ability to turn on turn off recycle or lock out power to each individual PDU receptacle on a programmable or real time basis e Switchable outlets enable a number of advanced networking abilities such as remote reboot on demand of locked IT equipment custom power on power off outlet sequencing automatic load shedding of optional loads during power failures and disabling unused outlets to prevent the connection of unauthorized equipment loads e Remote interface provides data regarding input power conditions load level and individual outlet power status via secure network or web browser interface e Supports notification and logging of all major power events and user specified alarm thresholds e Optional ENVIROSENSE temperature and hum
4. control and monitoring functions by giving IT Managers the ability to turn on turn off recycle or lock out power to each individual receptacle and remotely monitor PDU power consumption and in rack environmental conditions Switched PDU systems can be accessed configured and controlled through secure web SNMP or Telnet Interface Individually switched outlets can be controlled via a built in web network interface enabling remote reboot of unresponsive network hardware User defined power up and power down outlet sequences ensure proper operation of interdependent IT systems and prevent inrush related overloads as devices are powered on Programmable load shedding of less critical devices at user defined intervals extends UPS uptime in response to power failures Unused PDU outlets can be electronically locked off to prevent powering of unauthorized hardware PDU power consumption current is displayed locally and can be monitored via the web network interface with user defined alarms to warn of potential overloads before critical IT mains or branch breakers trip Optional ENVIROSENSE temperature humidity probe enables remote monitoring of in rack environmental conditions and alarms for up to 3 user supplied contact closure sensors Supports real time monitoring notification and logging of all on board reporting functions with user specified alarm thresholds and actions for each reported condition Applications e Ideal for configurations requiring a
5. ctor Horizontal 1U 2U etc ENVIRONMENTAL Relative Humidity Up to 95 non condensing COMMUNICATIONS SNMP compatibility Yes pre installed SNMPWEBCARD provides remote monitoring via web telnet and SNMP management systems Remote management gives user ability to turn connected loads on or off individually SPECIAL FEATURES Appearance Black 1U rackmount steel chassis CERTIFICATIONS Certifications Tested to UL 60950 1 USA Canada Class A Emissions NOM Mexico RoHS compliant WARRANTY Product Warranty 2 year limited warranty Period U S Canada amp Puerto Rico Related Items Optional Products Product Type Related Model Description Qty Extended Warranties WEXT3 PDU NET 3 Year Extended Warranty For Switched PDUs ending with NET 1 Extended Warranties WEXT5 PDU NET 5 Year Extended Warranty For Switched PDUs ending with NET 1 Power Cables P007 002 2 ft Heavy Duty 14AWG Power cord 1 IEC 320 C13 to NEMA 5 15P Power Cables P007 006 6 ft Heavy Duty 14AWG Power cord 1 IEC 320 C13 to NEMA 5 15P Power Cables P007 010 10 ft Heavy Duty 14AWG Power cord 1 IEC 320 C13 to NEMA 5 15P Power Cables P010 012 12 ft 18AWG Power cord 1 NEMA 5 15P to IEC 320 C13 Power Cables P022 001 1 ft 18AWG Power Extension cord 1 NEMA 5 15R to NEMA 5 15P Power Cables P023 001 1 ft 14AWG Power Adapter cord 1 NEMA L5 15R to NEMA 5 15P Power Cables P034 010 10 ft 14AWG Heavy Duty Power cord 1 IEC 320 C19 to NEMA 5 15P
6. idity probe enables remote monitoring of environmental conditions and the ability to report conditions from up to two contact closure sensors e Optional ENVIROSENSE accessory also supports the connection of up to three user supplied contact closure sensors to selectively notify monitor and log reported conditions such as rack door access e DHCP Manual configuration support provides the ability to have network settings automatically assigned to the card or manually assigned via permanent IP addresses e 10 100 Mbps auto sensing allows optimal communication compatibility with your current 10 100 Base T network e Real time clock backup maintains the time of day and date even if the PDU is shut down and unpowered e 2 tier level access allows an administrator and a guest to log into the web browser for monitoring and or management of all intelligent PDUs and similarly equipped UPS systems e Alert notifications via email or SNMP traps give users the added advantage of having an immediate event notification e Protocols supported include HTTP HTTPS PowerAlert Network Management System SMTP SNMPv1 SNMPv2 Telnet FTP DHCP BOOTP NTP e Front panel ammeter displays total PDU power consumption e On initial power up outlets are automatically energized at 250 millisecond intervals to prevent inrush related equipment interaction and mains circuit overloads e Included cord retention brackets keep vital network equipment plugged in and continuously powered
7. iia Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 lt E mail saleshelp tripplite com Model PDUMH15NET Single Phase Switched PDU 15A 120V 1U Horizontal Rackmount NEMA 5 15R outlets NEMA 5 15P input plug Highlights e 1U switched PDU with digital current monitoring network interface and individually controllable outlets e 15A 120V capacity with 16 NEMA 5 15R outlets and 5 15P input plug e Enables ability to turn on turn off power cycle or lock out power to each individual outlet e Programmable or real time outlet power control via built in SNMP web network monitoring and control card e Automatic sequential outlet turn on prevents inrush related equipment interaction on startup e Cord retention brackets keep vital equipment plugs connected Description PDUMH15NET Switched Metered 1U horizontal rack PDU supports 15A maximum capacity at 120V agency de rated to 12 amps Includes attached 5 15P input cordset and 16 5 15R switched outlets 8 front 8 rear Visual and remote current monitoring tracks the output current Supports 1U horizontal rackmount installation in 2 or 4 post racks plus OU vertical wallmount and under counter installation in many applications Included cord retention brackets keeps vital network equipment plugged in and continuously powered Tripp Lite Switched Metered Rack Power Distribution Units enable a variety of advanced network