1. lt Delete storage position gt Total length 2 digits Ex Delete user stored on position 1 enter 01 Note An exiting user can also be deleted by adding a new user on the same storage position l e it is not necessary to use the delete command first All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 16 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 8 4 Change System Configuration Command 1 This command can change the system configuration setting and thereby be customized to your needs Values 2 digits 0 60 s 2 digits 0 20 s 1 digit 0 2 Parameters lt door remain open time gt lt door buzzer time gt lt door type gt lt Alarm Light control gt 1 digits 0 2 2 digits 0 10 2 digits 0 60 min lt User alarm arming gt lt Light switch off time gt Description The number of seconds the lock must remain open minimum time The time will not be extended if a valid user is constantly seen or REX button kept pressed l e the gate door will be closed after this time period Ex 5 s is written as 05 0 s door will not be activated Default 05 The number of se
2. cccsssccesssnseceeeeeeeeeeees 19 9 RegueEst Ek REX Push BUTTON mirae a ntact A N N E 21 10 Alarm Arming and Disarming cciazisncsascissacaadinnasienntiaatneiaaascsenranasnceiaieasnesianasiiniaddntaeelaniataniasnaniaeninns 21 DOSE Disarming the Alat Mecernicnnnnea i R R 21 10 2 Armine eA Minnanna a aa 21 10 3 Timing Diagram of the outputs Normal Access and Arming the Alarm 22 10 4 Timing Diagram of the Outputs Normal Access and Reject Arming of the Alarm 22 11 Virtual Keypads mnnn nan aA N T ERA ER 23 11 1 Virtual Keypad Oniy MOG ccisncearscncarsctiaseal endear A N T E 23 11 2 Virtual Keypad Mixed ModE nsrotisizunrinne a a a 23 12 User ACCESS Key SCtU Ptaisscisicecscansieddcactecsansaeceadeccaned A A RAEES 24 12 1 Mobile Phone as Kayanin i a E A E R 24 12 2 GPS Key aS K Vorri a a e A A 25 13 Door Gate Output TYPe ce ccsccessccssecsscecssecssesseeesesseesesseeseessecsaecesesessecsseeeessecsaeeseesaeeeeesesaeeeeees 26 T PUSE isnan R aore oiis 26 13 2 l ye lirainen R REE aaa a ATEA EAEE 26 TS Ue dito plejan nan a a E EA AEE 26 14 Access Detection RANG CG mariera ni A E EET EEO 27 14 1 Detection Range Command Examples ssieicssicicscscascddtncaccasiasasesdsdenatdeainanantaseasandddatsnendaesmeanads 27 14 2 Detection TANS 85 to SWOT E aes apices ccccashensatess seas i E T 28 14 3 D tection tange is too TONE kemirgan uaaa aaae 28 15 Default Factory System Setting sic ccsicsscsacaredesasacacosdaacadicaieanedosasdasiaiacacens
3. o Alarm _ __ Alarm is d disarmed Alarm is arme All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 22 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 11 Virtual Keypad The system has a wireless virtual keypad functionality which can operate in two different modes Virtual Keypad only Mode and Virtual Keypad Mixed Mode This feature will allow access to all users that know the 4 digit access PIN code or to any witha Bluetooth device 11 1 Virtual Keypad only Mode The system can be configured to run as a purely virtual keypad l e no users have to be added The system administrator adds a user with the special BD address FFFFFFFFFFFF not a valid BD address and a 4 digit access PIN code on storage position 03 Refer to section 8 2 Add new User Command The system will in this mode grant access to all users who enter the correct 4 digit access PIN code The request for PIN code is disabled when 0000 is entered as PIN code and thereby give access to all with a Bluetooth enabled device l e a simple gate or door opener The system administrator can at any time change the PIN code Caution If this special user
4. User Manual MVC Data 12 User Access Key Setup In principal all Bluetooth enabled devices can function as user access keys If entering of PIN code is required the device must have a suitable keypad to enter the code The used Bluetooth device must also be configured to be visible from other Bluetooth devices to allow it to be detected by other Bluetooth devices Please refer to MVC Data How to Get the Bluetooth ID paper http www mvc data com Misc html Note The time it takes to detect a nearby user can be influenced by The time Bluetooth inquiry scan time e g a mobile phone uses to scan for other Bluetooth devices that want to connect to it The time is typically set to a low value to preserve battery power l e the time to discover a nearby Bluetooth enabled mobile phone strongly depends on implementation details for a particular mobile phone Radio noise from other radio communication in the 2400 2483 5 MHz ISM frequency band e g WI FI access points and other Bluetooth activity etc can course disturbances of the radio signals to from the Bluetooth transceiver and consequently increase the detection time Metal surfaces in the vicinity can also course disturbances distortion or prevent radiation of the radio signals to and from the Bluetooth transceiver How the mobile phone device is held in the hand may have an significant impact on the radio signals to and from the Bluetooth transceiver 12 1 Mobile P
5. Users Normal Operation Follow these steps to enter configuration mode Steps 1 Power off the module 2 Press and held down the REX Request Exit push button IN2 3 Power on the module again 4 The REX push button can be released after the short beep The system is now in configuration mode for 10 minutes and will flash with the Blue LED Refer to section 7 3 How to enter System Commands Configuration Mode for how to enter system commands The system coverage range will be limited to approximately 20 cm in the configuration period to prevent that unauthorized people can tamper with the system The configuration period is restarted every time a valid command has been executed Configuration mode is automatically terminated after 10 minutes without any valid commands by sending 2 short beeps or by power cycling the device to startup in normal operation Note The system will not scan for detect users in configuration mode l e no access is possible All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 10 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 7 3 How to enter System Commands Configuration Mode The system commands
6. alarm 10 2 Arming the Alarm The system will arm the alarm again when a valid user with arming permission refer to section 8 4 Change System Configuration Command 1 has been detected and the user afterwards presses the REX push button The alarm is kept armed until a valid user with disarming permission disarms it again All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 21 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 10 3 Timing Diagram of the outputs Normal Access and Arming the Alarm Case with active high outputs shown Nokmaliicer access ete pushes Wa 10 miea User pushes the REX with PIN code with gate utton to arm the etna wi button again to exit the activation alarm active buzzer door gate if ptart it Gate J oe a Alam F E Alarm j t disarmed Alarm is armed 10 4 Timing Diagram of the Outputs Normal Access and Reject Arming of the Alarm Case with active high outputs shown User pushes the REX button again to reject arming of the 10s reject alarm Normal user access ei eee ca odwith alarm y F armin erioag WI with PIN code with gate HOSO SARIS ti a x active buzzer activation atari oo ptart Stpp Gate _
7. 0 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 2010 01 21 US 1 03 17 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data Total length 15 digits Ex to activate the door mechanism for 5 s with 1 s warning buzzer on open close level door type enable light control function for the first 5 user enter 05 01 1 1 05 10 The system settings can be reset to factory value Please see section 15 Default Factory System Settings System administrator should maintain a system log with changed System Settings for Normal Operation Mode Please see 18 Appendix C System Configuration Log Template All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 18 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 8 5 Change System Configuration Command 2 Advanced settings This command can change the additional system configuration settings and thereby be customized to your needs Caution Caution must be taken when changing these system configuration parameters Please refer to section 14 1 Detection Range Command Examples Parameters Values Descrip
8. 00 Series GC1001 GC1004 User Manual MVC Data 19 3 Mobile Phone as Access Key Any Bluetooth enabled mobile phone can be used as access key No software has to be installed on the mobile phone The system will detect the mobile phone when it comes within the specified detection range TIP No pairing or search for devices must be active on the used mobile phone Steps 1 Enable Bluetooth on mobile phone and set it to visible Refer to the mobile phone s User Manual 2 Enter the 4 digit access PIN code when prompt If PIN code is required Note The time Bluetooth inquiry scan time a mobile phone uses to scan for other Bluetooth devices that want to connect to it is typically set to a low value to preserve battery power l e the time to discover a nearby Bluetooth enabled mobile phone strongly depends on implementation details for a particular mobile phone All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 33 33
9. 00 Series GC1001 GC1004 User Manual MVC Data 3 Security Precautions Several security precautions have been implemented in the system to make it safe to use The system will only accept system configuration commands in a special configuration mode refer to section 7 2 How to enter Configuration Mode All system configuration commands are entered by temporarily changing the mobile phones friendly name and must be followed by a unique 8 digit master PIN code The master PIN code should only be known to a limited number of people system administrators The 8 digit master PIN code should be changed and is unique for each GC1001 GC1004 system It can be entered from any Bluetooth enabled mobile phone Please change this PIN code before continuing Two privileged users administrators can add and delete users at any time Refer to section 7 4 How to Add or Delete Users Normal Operation Caution The Bluetooth friendly name feature is used for commands and can be read from another Bluetooth device from the distance typically up to 10 meters Therefore it is highly recommended to immediately change the Bluetooth friendly name again or make the mobile phone invisibly to avoid that unauthorized people read the commands containing vital user information All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyrig
10. 1000 Form factor 200 x 120 x 60 mm The system is also available with Bluetooth RS232 RS422 RS485 and LAN interface to the PC based PcManagement system as C2000 up to 2000 users 512 logs I O 3 3 GC3000 up to 2000 users 512 logs I O 4 4 GC4000 up to 2000 users 512 logs I O up to 8 8 Please see the GC1000 GC2000 GC3000 GC4000 series Installation Manual for instructions on how to install the system Get easy and seamless accesses to the secured areas with your mobile phone working as a secure access key from a distance of 0 1 up to 10 meters All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 2 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data Table of Contents 1 ISI SUNHET se srecaiassnciatacinncicceunaianasaiesnanaalaacsunsiasauaacesdaaaiassansunntasancaniedeasdatansiaeloatueiaagstatadabandaasennace 5 2 NOVO C WTION aiacvcgiiscn tence iauswa eedee arama amin eater amas alanine a 6 3 Security PRECAU LIONS xcctadetinecectcerethombewtauicluetetiecniant octewtaeasaoneyeudaingpeanbivialbiatesneluenaahtcmnnetntimiucteneteteeats 7 A System OVERVIEW vissitiscasneisssivnedsacdteanesaaventjacatenteasavacasanasdadgsadsielgaasiagd EEA EA
11. 1000 series GC1001 GC1004 are stand alone access control systems They are well suited for use in private homes shops and minor companies They are unique wireless access control systems built on Bluetooth wireless technology a wireless technology that operates in the license free ISM band at 2 4 GHz The systems only allow access to users who can be identified by their unique Key ID and optional a 4 digit PIN code for increased security The used mobile phones or other Bluetooth devices must be set to visible to allow them to be discovered by the system The GC1000 series eliminates the need for mechanical readers and keyboards outside the secured area This removes the risk for property damage and breakdown due to harsh environmental conditions and heavy use Please refer to the GC1000 Firmware Release Note for the latest changes Firmware version 1 72 introduces more users The 2 privileged users administrators are now added as additional users l e all system has been updated with 2 more users l e GC1001 has now 7 2 5 GC1002 12 2 10 GC1003 22 2 20 and GC1004 52 2 50 users All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 6 33 AccessZone GC10
12. 6 Appendix A User Log Template Write your log of permitted users and store in a safe place Storage Position User Name Bluetooth Address PIN Code 17 Appendix B System Master PIN Code Log Template Write your master PIN code here and store in a safe place System Master PIN Code 18 Appendix C System Configuration Log Template Write your configuration setting here and store in a safe place System Configuration 1 System Configuration 2 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 84 02 30 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 19 Appendix B Quick Guide Users must first be added to the system with an optional 4 digit user access PIN code before access can be granted All system commands e g add user can be send from a Bluetooth enabled mobile phone Please refer to section 7 How to Configure the System for more details about the different commands 19 1 Mobile Phone used for Adding and Deleting Users Normal Operation The privileged users administrators on storage position 01 and 02 can add and delete users in normal operation The user is first requested the normal 4 digit access P
13. AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data GC1000 Series GC1001 GC1004 User Manual New Generation of Wireless ccess Control Systems User Manual for GC1001 GC1004 with firmware Ver 1 72 and above For modules with serial numbers from 120000 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 1 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data AccessZone System A Key to a Safer Future Congratulations on choosing an AccessZone Access Control System It is a flexible and easy to use system for controlling access to doors and gates to private homes shops and small and middle size companies It enables quick configuration with a few simple commands entered on a standard mobile phone with Bluetooth without installing any software No license or subscription is required This manual covers the easy configuration of the AccessZone GC1000 series of stand alone g Access Control Systems via a mobile phone pa y p o GC1001 2 admin and 5 users He GC1002 2 admin and 10 users GC1003 2 admin and 20 users A Key to a Safer Future GC1004 2 admin and 50 users AccessZone GC
14. Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 19 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data Total length 14 digits Ex To select power range 2 lt 10 m and approximately 0 5 m with input 1 and 2 active at low level GND and output 1 and 2 with high level enter 2 6 50 0 0 1 1 There is a close relation between parameters lt power range gt lt TX power level gt and lt Detection range gt The system detection range depends on selected lt power range gt lt TX power level gt Shortest detection range is with lt power range gt 1 lt TX power level gt 1 and lt Detection range gt 0 Longest detection range is with lt power range gt 3 lt TX power level gt 8 and lt Detection range gt 99 System must be power cycled for changes to take effect The System settings can be reset to factory value Please see section 15 Default Factory System Settings Please see section 14 Access Detection Range for some typical values for lt power range gt lt TX power level gt and lt Detection range gt and how to adjust detection range System administrator should maintain a system log with System Settings 2 for Normal Operation Mode Please see 18 Appendix C System Configuration Log Template All information is subject to change without notice All other products and brand names are
15. IN code if used Then it will prompt for the 8 digit Master PIN code if the privileged user administrator has entered a valid add user or delete user command Steps 1 Enable Bluetooth on the mobile phone and set it to hidden 2 Temporarily change the Bluetooth friendly name to the desired command Examples e Add User Refer to section 8 2 Add new User Command Add unique user 0022b4b62918 with PIN code 1234 enter on position 1 01 0022b4b62918 1234 or Add unique user 0022b4b62918 without PIN code enter on position 1 01 0022b4b62918 0000 or Add unique user 0022b4b62918 with PIN code 1234 and strong enter on position 1 01 0022b4b62918 1234 1 or Add unique user 0022b4b62918 without PIN code and weak enter on position 1 01 0022b4b62918 0000 3 e Delete User Refer to section 8 3 Delete User Command Delete user stored on position 1 enter 01 3 Set the mobile phone to visible 4 Enter 4 digit access PIN code on mobile phone when prompt access is granted if correct 5 Wait for 3 short beeps which indicate that a valid command has been found and Master PIN code is required 6 Enter 8 digit Master PIN code on mobile phone when prompt acknowledge with a short beep for successful execution 7 Set the mobile phone to invisible hidden 8 Erase the command in the mobile phone For more commands repeat step 1 7 If no more commands are required Set friendly name back to desired name All information is su
16. Please refer the GC1000 GC2000 GC3000 GC4000 series Installation Manual for a LED description All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 8 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 7 Howto Configure the System This section describes how to enter system commands and how to enable the system for configuration Section 8 System Commands describes the different commands in details 7 1 Commands via Mobile System configuration adding deleting users and changing system settings can be done from any Bluetooth enabled mobile phone Note It is not necessary to install any software on the mobile phone or use any PC tool The mobile phone used must support at least 20 characters as Friendly Name also called Phone Name This is the name revealed for other Bluetooth devices A system command e g 01 0022b4b62918 1234 is entered by temporarily changing the mobiles Bluetooth Friendly Name Refer to section 8 System Commands Please refer to the User Manual for a specific mobile phone type for how to change the Bluetooth friendly name Caution The Bluetooth specification states a maximum length of 248 characters as Fri
17. RE ERES 8 SMO DESErPUO Maian E A E N EA A E E A RAE 8 SL MOS nan n E E E a E A ER 8 SERTIN oE i A E E E A A E EE E A T 8 OE SS as cic ar azcapiascanaveicarauanasmuania use iaaacen a E E 8 7 HOW to Configure the Syste Miasaicaseussasecsassacaasinniaiaiancdicnasantianscnceassianenaleiehidansaeneasianndarseasesdaanuniiend 9 Tg OUTS via Mobil S aaceeiseasecesantenddevadelidevsicy dawned n E aaatenleuds Vente ete eard dads 9 7 2 Howto enter Configuration Mode creron aR O E ENT 10 7 3 How to enter System Commands Configuration MOG scsicisisisssssciacsssnesscssiosccanssastizacsaasatants 11 7 3 1 lf the system doesn t respond to a commandissssssierrsieiineriinieriirenrriiiirr iniisa 11 7 4 How to Add or Delete Users Normal Operation aisescississssctiocssserecsesstaceanssatdcastecesatsatsaneaanians 12 7 4 1 If the system doesn t respond to a COMMANG ccascscscessscsercessvercoscsesseasanscnessadecssonassanssansean 12 8 System ComMand Seseent E e E EERE 13 8 1 Change 8 digit Master PIN Code CoOminanGsicsissascssecctatiseatsiareacisaisrascetansanasascspaneedeeaantaasincaans 13 8 2 Add new User COIN ANG xascicsicrs casachesaudeacexotaaimvsiaeanansaceacumnssssanunesniaramlasetuntntstunseeessimehatenamsmensian 14 8 3 Delete User Command erisspriniasi anenee e aaa Oi 16 8 4 Change System Configuration Command 1i s caxzecusanisassanseaiaianaisadapauntiarsanateiantiaaaiaindaniaaisaiaiis 17 8 5 Change System Configuration Command 2 Advanced SettingS
18. adding deleting users and changing system settings can be executed from any Bluetooth enabled mobile phone by temporarily changing the mobile phones friendly name After entering a command and the master PIN code the system gives a short beep to indicate that the command has been accepted and executed and restarts the 10 minute configuration period The next command can be entered or wait for the termination of the configuration period or power cycle the device to startup in normal operation Note 3 short beeps indicate when to use the master PIN code instead of normal access PIN code Follow these steps to execute commands Steps 1 Set system into configuration mode Refer to section 7 2 How to enter Configuration Mode 2 Enable Bluetooth on mobile phone and set it to hidden 3 Enter the required system command on the mobile phone and click save Refer to section8 System Commands for available commands 4 Set the mobile phone to visible 5 Place mobile phone within the detection range of the system 6 Wait for 3 short beeps 7 Enter Master PIN code e g 12345678 when prompt 8 Wait for beep for successful execution of the command 9 Set the mobile phone to invisible hidden 10 Erase command from mobile phone If more commands must be executed repeat step 2 9 7 3 1 If the system doesn t respond to a command System is not in configuration mode any more 10 minutes time out Check Blue LED flashing Else re enter configu
19. ase an existing user first System administrator should maintain a system log of users and storage positions used Please see 16 Appendix A User Log Template Caution A virtual user is by default factory added at storage position 01 to allow easy configuration of users without going through the normal system configuration mode The default PIN code is 1234 Command 01 FFFFFFFFFFFF 1234 It is highly recommended to overwrite this with a specific user with a unique PIN code All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 15 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 8 3 Delete User Command This command deletes a user from the system This command can also be execute in normal mode by the privileged users administrators on storage position 01 and 02 Parameters Values Description User position to delete from system database 2 digits 01 02 Privileged users administrators 01 02 03 07 Normal users GC1001 03 07 03 12 Normal users GC1002 03 12 03 22 Normal users GC1003 03 22 03 52 Normal users GC1004 03 52 Ex position 1 01 8 08 and 10 10
20. ataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 4 ET AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 1 Disclaimer All rights reserved MVC Data ApS assumes no responsibility for any errors in this manual MVC Data ApS is constantly working to improve its products and offer new features in collaboration with customers and partners Therefore MVC Data ApS reserves the right to change the hardware software and or specifications without notice and shall have no obligation to update the information contained in this manual MVC Data ApS s products are not authorized for use as system critical components in life supporting devices or systems AccessZone is a registered trademark of MVC Data ApS The Bluetooth trademark is owned by the Bluetooth SIG All other trademarks are owned by their respective owners The displayed screens may differ and depends on the mobile phone used for configuration Copyright 2005 2010 MVC Data ApS All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 5 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 2 Introduction The AccessZone GC
21. bject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 31 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 19 2 Mobile Phone used for System Commands System Configuration Mode All mobile phones can in system configuration mode be used to enter system commands like adding and deleting users Refer to section 7 2 How to enter Configuration Mode for more details about the systems commands The system will prompt for the 8 digit Master PIN code if a valid system command is found Steps 1 Set system into configuration mode by holding the REX button pressed while powering up the device Refer to section 7 2 How to enter Configuration Mode for more details 2 Enable Bluetooth on the mobile phone and set it to hidden 3 Temporarily change the Bluetooth friendly name to the desired command Examples e Change Master PIN Refer to section 7 2 How to enter Configuration Mode Change Master PIN to 12345678 enter 12345678 e Add User Refer to section 8 2 Add new User Command Add unique user 0022b4b62918 with PIN code 1234 enter on position 1 01 0022b4b62918 1234 or Add unique user 0022b4b62918 without PIN code enter on position 1 01 0022b4b62918 0000 e Delete User Refe
22. conds the buzzer will warn before activating open close the gate Ex 1 s is written as 01 00 buzzer will not be activated Default 01 Specifies the door type to control 0 1s open pulse and 1 s close pulse 1 level 2 latched A gate e g garage port is typically type 0 and a normal door is typically type 1 To keep the door gate open the latched type can be used This type toggles the output on each access Default 1 The system can be configured to bypass an alarm system or switch on the light on access O Alarm latched output T Light Control latched for the specified time period 2 As 0 and access PIN code will only be required when the alarm is active ON Default 0 The number of users who are allowed to arm disarm the alarm All users with a lower or equal storage number can use this feature when lt Alarm Light control gt is set to 0 Ex First 5 users is written as 05 00 Alarm function is disabled Default 05 The number of minutes the light control output is active Valid for all users when lt Alarm Light control gt is set to 1 Ex 5 minutes light is written as 05 00 Light will not be switch off Default 10 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies Copyright 2005 201
23. ease see 17 Appendix B System Master PIN Code All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 13 if 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 8 2 Add new User Command This command adds a new user to the system This is also used for editing an exiting user Make sure to store the user on the same storage position This command can also be execute in normal mode by the privileged users administrators on storage position 01 and 02 Parameters Values Description Position in system database to store the user 2 digits 01 02 Privileged users administrators 01 02 03 07 Normal users GC1001 03 07 03 12 Normal users GC1002 03 12 03 22 Normal users GC1003 03 22 03 52 Normal users GC1004 03 52 Ex position 1 is written as 01 The unique Bluetooth address of device lt Add storage position gt lt BD address of new device gt 12 digits Valid values 0 9 and A F or a f Ex 001256ABCDEF OOBB592F030B User access PIN code Ex 1234 Use 0000 to disables use of access PIN code for that particular user Device power c
24. ease test and adjust as appropriate on location 14 1 Detection Range Command Examples The section shows some typical detection range commands you can use as a Starting point to find your own specific values The first to value 1 2 30 0 0 1 1 corresponds to the used transmitting power TX The next parameter 1 2 40 0 0 1 1 corresponds to the received signal strength Please refer to 8 5 Change System Configuration Command 2 Advanced settings for more details Here are some example commands to start with Range Distance System Command Very short range 1 2 30 0 0 1 1 1 4 50 0 0 1 1 2 3 60 0 0 1 1 2 6 70 0 0 1 1 Very long range 3 8 99 0 0 1 1 Note The values 1 2 40 0 0 1 1 in bold must match your requirements The default values are used in these examples Please follow the descriptions in section 14 2 Detection range is to short and 14 3 Detection range is too long for adjusting to desired detection range up or down All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 27 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 14 2 Detection range is to short Follow and repeat these steps to incremen
25. endly Name However most mobile phones have limited the space allowed for Friendly Name A minimum of 20 characters must be supported by the used mobile phone All commands must be followed by an 8 digit master PIN code for safe use The system gives 3 short beeps to indicate that a valid command has been found and the master PIN code is required The user will automatically be prompted when to enter the master PIN code Note This is not the normal 4 digit user access PIN code Please note when entering the commands All command parameters enclosed by lt gt must be separated by a comma No spaces between values are allowed Have the exact length as specified l e no additional characters in the end A indicates an integer range 1 2 3 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 9 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 7 2 How to enter Configuration Mode The system must be set into configuration mode before it will accept the system commands However it is possible for two privileged users administrators to use the Add new User and Delete User commands in normal mode Refer to section 7 4 How to Add or Delete
26. hone as Key Any Bluetooth enabled mobile phone can be used as access key No software has to be installed on the mobile phone The system will detect the mobile phone when it comes within the specified detection range TIP No pairing or search for devices must be active on the used mobile phone Steps 1 Enable Bluetooth on mobile phone and set it to visible Refer to the mobile phone s User Manual 2 Enter the 4 digit access PIN code when prompt If PIN code is required Note The time Bluetooth inquiry scan time a mobile phone uses to scan for other Bluetooth devices that want to connect to it is typically set to a low value to preserve battery power l e the time to discover a nearby Bluetooth enabled mobile phone strongly depends on implementation details for a particular mobile phone All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 24 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 12 2 GPS Key as Key A Bluetooth GPS antenna is also suitable as a simple wireless key It works fine with and without PIN code The PIN is typically fixed to 0000 or 1234 so the PIN code can typically be left out The GPS antenna must typically
27. ht 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 W 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 4 System Overview This section presents a system overview with an I O description Output 1 Input 1 amp 3 Pulse or Level latched Block Operation Door lock Gate control Prevents any door Gate activation Output 2 Level latched Alarm Arm and Disarm Light Control Switch Input 2 Key 1 REX Button Output 3 Alarm arming Level latched Alarms reject arming Door lock Gate status signal 5 1 0 Description GC1000 series have 3 outputs and 3 inputs The active levels high 1 low 0 when an action is performed can be configured inverted Please refer to section 8 5 Change System Configuration Command 2 Advanced settings for more details 5 1 Inputs Block Operation for preventing any door or gate activation on input 1 and 3 REX Button for exit and Alarm arming and disarming on input 2 and front key 1 5 2 Outputs Relay type 1 A Door lock Gate Control on Output 1 Door lock Gate Control status on Output 2 Alarm Arm and Disarm Light Control Switch on Output 3 Please see the GC1000 GC2000 GC3000 GC4000 series Installation Manual for instructions on how to install the system 6 LED Status The GC1000 series has 6 LEDs for system indications
28. ies anencianiaaarseiaaanetaimohineds 29 15 1 Restore Factory Default System Seti es is cscarcsccaasatiosdsasenadbioutatesnsbaievaasasenivadooratvebaisvanecucasiels 29 16 Appendix A User Log Template scsnriieniniceninninnin iio aa a a a 30 17 Appendix B System Master PIN Code Log Template cccsscccsssscccecssstececsssseeeeessnsnaeeeceeeeeees 30 18 Appendix C System Configuration Log Template ccscccccssscccessssscecessseeeeessaececeeeeeeeeeeeeees 30 19 App ndix B Quick Guide senaian ia A A Rai 31 19 1 Mobile Phone used for Adding and Deleting Users Normal Operation cccceeseeeeeee 31 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 84 02 3 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 19 2 Mobile Phone used for System Commands System Configuration MOode cccceseeeeees 32 19 3 Mobile Phone as Access Key c ccsssssccecececsssesssecececesesesseaecececsesesessseeeceseeeeeeeeeesesauaegasseees 33 All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC D
29. is placed on storage position 01 or 02 all users will have the ability to add and delete users privileged user if they know the correct access PIN code and the master PIN code This is not recommended 11 2 Virtual Keypad Mixed Mode The system can be configured to be a mixed mode virtual keypad with up to 4 9 19 or 49 unique users and 2 privileged user the number depends on purchased system and a virtual keypad user with the special BD address FFFFFFFFFFFF not a valid BD address and a 4 digit access PIN code The system will in this mode grant access to all unique users with their unique 4 digit access PIN code and all other users which enter the correct 4 digit virtual keypad access PIN code This feature allows the virtual keypad PIN code to be changed frequently without affecting the other users Caution The system will start to search for a match from position 01 going up The virtual keypad user must be placed after the last used storage position or store it on the last storage position 7 12 22 or 52 if you want to be able to add more users in the future All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 23 33 AccessZone GC1000 Series GC1001 GC1004
30. lass lt power class gt ae 1 strong device 2 standard device optional not required 3 weak device Default 2 lt PIN code for user gt 4 digits 1 Can be used to compensate normalize in some degree for power differences and antenna location between the used Bluetooth keys mobile phones fa device must be closer to the reader than most others before access is granted set parameter 3 weak device fa device gives access further away from the reader than most others set parameter 1 strong device All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 14 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data Total length 20 digits or optional 22 digits Examples Add unique user 0022b4b62918 with PIN code 1234 enter 01 0022b4b62918 1234 Add unique user 0022b4b62918 without PIN code enter 01 0022b4b62918 0000 Add unique user 0022b4b62918 without PIN code and strong enter 01 0022b4b62918 0000 1 Add unique user 0022b4b62918 without PIN code and weak enter 01 0022b4b62918 0000 3 Note Any exiting user on the storage position selected will be erased l e it is not necessary to er
31. n normal configuration mode TIP Make sure that the mobile phone used is stored on position 01 or 02 before continuing Follow these steps to add or delete a user Steps 1 Enter the required Add new User or Delete User command on the mobile phone and click save refer to section 8 2 Add new User Command and 8 3 Delete User Command 2 Set the mobile phone to visible 3 Place mobile phone within the detection range of the system 4 Enter normal access PIN e g 1234 when prompt Gate door is activated if correct 5 Wait for 3 short beeps 6 Enter Master PIN code e g 12345678 when prompt 7 Wait for beep for successful execution of the Add new User or Delete User command 8 Set the mobile phone to invisible hidden 9 Erase command from mobile phone If more users must be added deleted repeat step 1 8 7 4 1 If the system doesn t respond to a command The administrator is outside the normal access range Administrator must get closer to the system The command has already been executed Try change one of the parameters or try another command The command is not valid Wrong number of parameters wrong parameter values and or wrong command length e g spaces at the end The system time out waiting reading the command or connection to mobile failed Wait for next detection All information is subject to change without notice All other products and brand names are registered trademarks of their respective companie
32. not have an active connection to another Bluetooth device to be detectable visible Note PIN 0000 means no PIN code in the GC1000 system Some battery powered devices will automatically switch off after e g 60 minutes to preserve battery power Please refer to the GPS user manual for more details All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 25 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 13 Door Gate Output Type The GC1000 series support 3 different door gate output types Pulse Level or Latched toggle to support different door gate mechanisms All types can be combined with a warning buzzer period before gate activation warning buzzer can also be switched off Select the type suitable for your door or gate 13 1 Pulse A 1 second pulse is used to activate the gate and another 1 second pulse is used to close the gate again after the time out of the remain gate open time period Door Gate Output 2 a es en Warning open time with buzzer Warning close time with buzzer 13 2 Level A pulse is used to activate the gate The length of the pulse depends on the remain open time period Door Gate Output 2 _ Warning
33. open time with buzzer Warning close time with buzzer 13 3 Latched toggle The output is kept from one valid access to the next where it changes toggle Door Gate Output 2 Warning open time with buzzer Warning close time with buzzer All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 26 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 14 Access Detection Range The detection range may be influenced by the surroundings at the installation location indoor or outdoor If metal is close by reflection may increase decrease the detection range It may also vary between the different used devices mobile phones l e some devices have a longer shorter range than others because of different antenna designs and where and how they are placed e g held in the hand or placed in the pocket etc The system has some advanced and unique features to make individual adjustments of the detection range Both the transmitted power TX and received signal power RX can be adjusted to compensate the installation environment and individual requirements If the detection range is not as expected the values can be adjusted up down to find a suitable set of values Pl
34. r to section 8 3 Delete User Command Delete user stored on position 1 enter 01 e Door Remain Open Time Refer to section 8 4 Change System Configuration Command 1 Activate the door mechanism for 5 s with 1 s warning buzzer on open close level door type enable alarm function for the first 5 user enter 05 01 1 0 05 10 e Change Detection Range Refer to section 8 5 Change System Configuration Command 2 Advanced settings Select power range 2 lt 10 m and approximately 5 m with input 1 and 2 active at low level GND and output 1 and 2 with high level enter 2 6 50 0 0 1 1 4 Set the mobile phone to visible 5 Place mobile phone within the detection range of the system 6 Wait for 3 short beeps which indicate that a valid command has been found and Master PIN code is required 7 Enter 8 digit Master PIN code on mobile phone when prompt 8 Wait for beep for successful execution 9 Set the mobile phone to invisible hidden 10 Erase the command in the mobile phone For more commands repeat step 2 9 If no more commands are required Set friendly name back to desired name All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 32 33 AccessZone GC10
35. ration mode Refer to section 7 2 How to enter Configuration Mode The administrator is outside the allowed configuration range Administrator must get closer to the system The command has already been executed Try change one of the parameters or try another command The command is not valid Wrong number of parameters wrong parameter values and or wrong command length e g spaces at the end The system time out waiting reading the command or connection to mobile failed Wait for next detection All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 11 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 7 4 How to Add or Delete Users Normal Operation Privileged users administrators are stored on storage position 01 or 02 These two privileged users administrators are allowed to add and delete users from normal operation mode l e it is not necessary to enter configuration mode first The user administrator must first enter the normal access 4 digit PIN code as normal and if a valid and new Add new User or Delete User command is found the 8 digit master PIN code A short beep indicates that the command has been successfully executed as i
36. registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 20 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 9 Request Exit REX Push Button Signals involved Input 2 and Output 2 A REX push button can be connected to the system on input 2 IN2 The REX push button must be installed on the secured side and will allow easy exit by activating output 2 OC2 without using a mobile phone A mobile phone is required to arm disarm the alarm system connected to output 1 OC1 The REX push button cannot do this alone However the REX push button is required with the alarm arming and disarming feature 10 Alarm Arming and Disarming Signals involved Input 2 and Output 1 The system can arm disarm an alarm system Output 1 OC1 is a latched output and the signal can be inverted Refer to section 8 4 Change System Configuration Command 1 The REX push button on input 2 IN2 is also used with this feature 10 1 Disarming the Alarm The system will disarm the alarm by activating output 1 OC1 when a valid user with disarming permission refer to section 8 4 Change System Configuration Command 1 has been detected The alarm is kept disarmed until it is armed again Note Pressing the REX push button will only activate the door gate Not disarm the
37. s 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 12 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 8 System Commands This section describes the simple and easy to use mobile configuration command set for GC1001 GC1004 the stand alone series 8 1 Change 8 digit Master PIN Code Command This command changes the master PIN code which is used to validate all system commands The system will automatically prompt the user for the Master PIN code The Master PIN code is a system code for authenticating the user system administrator Caution The default master PIN code should be changed before use of the system The Master PIN code should only be known by a system administrator or a limited number of people to avoid unauthorized use Parameters Values Description The Master PIN code for adding removing users lt New Master PIN code for the system gt 8 digits and change system settings Default 12345678 Total length 8 digits Ex To change Master PIN to 12345678 enter 12345678 Note The present old Master PIN code must be entered on the mobile to enable the new Master PIN code The Master PIN code can be reset to factory value Please see section 15 Default Factory System Settings System administrator should store the new master PIN code in a system log Pl
38. t the detection range Increase 5 the lt Detection range gt value If lt Detection range gt 99 is not enough increase 1 lt TX power level gt and set lt Detection range gt 50 Check detection distance follow adjusting procedure depending on result Final adjustment can be done by changing 1 the lt Detection range gt value 14 3 Detection range is too long Follow and repeat these steps to shorten the detection range Decrease 5 the lt Detection range gt If lt Detection range gt 0 then decrease 1 the lt TX power level gt value and set lt Detection range gt 99 Check detection distance follow adjusting procedure depending on result The final adjustment can be done by changing 1 the lt Detection range gt value All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 8402 28 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 15 Default Factory System Settings Here is a short recap of the systems default settings Virtual Keypad user OxFFFFFFFFFF with PIN 1234 is default on storage position 01 Door gate remain open time is set to 5 seconds Alarm arm disarming is enabled and can be used by the first 5
39. tion Maximum transmit power range TX 1l 0 1m 2m 1 digit i lt power range gt 2 0 5m 10m 3 5m 100m Default 2 idiei System transmit power TX level lt TX power level gt amp 1 0 1 m 8 10 m 1 8 P Default 8 T Device detection range RX 2 digits ate eee lt Detection range gt 00 shortest distance 99 longest distance 00 99 a Default 40 1 digit O low active GND 1 high active open lt Input1 active level gt ri beun 1 digit O low active GND 1 high active open lt Input2 active level gt heed pects or O low active GND 1 high active 12V DC lt Output1 active level gt Default 1 Open collector output for alarm light O low active GND 1 high active 12V DC lt Output2 active level gt Default 1 Open collector output for gate door Note Input 3 and input 4 are by default low active 0 GND and cannot be changed The figure show the relation between TX and RX A mobile phone must be within the RX green zone and TX should ideally be on RX or a little longer Mobile phone is ae NOT detected Mobile phone is granted access A mobile phone between TX and RX is detected but no access All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03
40. users Detection range is approximately 20 40 cm Master PIN code is 12345678 Please change this as the first thing Below is a list of the commands for the default factory settings These can be restored System Master PIN Code 12345678 Default System Settings 1 Normal Operation Mode 05 01 1 0 05 10 Note Settings in bold is fixed for the duration of the system configuration mode System Settings 2 System Configuration Mode Default System Settings 2 Normal Operation Mode 2 8 40 0 0 1 1 1 3 40 0 0 1 1 Default User 01 FFFFFFFFFFFF 1234 2 15 1 Restore Factory Default System Settings The Master PIN code and the other system configuration settings can be restored to factory settings Please follow the below steps Steps Power off the device Press and hold down front key 2 Power on the device Wait a short beep acknowledges that the factory settings have been restored Release front key 2 again Power off the device again Device can safely be re powered with the restored factory settings All information is subject to change without notice All other products and brand names are registered trademarks of their respective companies 2010 01 21 US 1 03 Copyright 2005 2010 All rights reserved MVC DataApS Skalhuse5 9240 Nibe Denmark Web www mvc data com E mail info mvc data com Phone 45 25 12 84 02 29 33 AccessZone GC1000 Series GC1001 GC1004 User Manual MVC Data 1