Home

W-Ie–Ne-R - AB-BDI-BL

image

Contents

1. W Ie Ne R TCP IP Protocol for WIENER power supplies User s Manual Nov 26 2003 1 PRELIMINARY General Remarks The only purpose of this manual is a description of the product It must not be interpreted as a declaration of conformity for this product including the product and software W Ie Ne R revises this product and manual without notice Differences of the description in manual and product are possible W Ie Ne R excludes completely any liability for loss of profits loss of business loss of use or data interrupt of business or for indirect special incidental or consequential damages of any kind even if W Ie Ne R has been advises of the possibility of such damages arising from any defect or error in this manual or product Any use of the product which may influence health of human beings requires the express written permission of W Ie Ne R Products mentioned in this manual are mentioned for identification purposes only Product names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies No part of this product including the product and the software may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any form by any means with the express written permission of W Ie Ne R Nov 26 2003 2 PRELIMINARY 1 Introduction Supported TCP IP protocols Internet Datagram Pro
2. an tray software version Yes No VersPS Power supply software version Yes No SerNoFan Fan tray serial number Yes No SerNoPS Power supply serial number Yes No TimeFan Fan tray operating time Yes No TimePS Power supply operating time Yes No Unom Nominal output voltage Yes Yes Ufine Output voltage fine adjust Yes Yes Inom Nominal current limit Yes Yes Umin Minimum output voltage for good status Yes Yes Umax Maximum output voltage for good status Yes Yes Imax Maximum output current for good status Yes Yes OVP Crow Bar detection threshold Yes Yes TempWarn External temp sensors warning level Yes Yes TempErr External temp sensors error level Yes Yes The details of the data structures and a sample software will be provided at a later time RFC 1350 Nov 26 2003 6 PRELIMINARY
3. hannel e g 5V Column Voltage The measured voltage at the backplane Column Current The measured current Column Status Status of the channel Possible is OK OV voltage too high UV voltage too low OC current too high OVP hardware overvoltage protection TEMP power supply temperature too high Refresh Rate Number of seconds of the automatic refresh 0 no automatic refresh WWW BINARY External Temperature Sensors Temperature of the optional external temperature sensors 1 The WWW access of this function can be disabled see BINARY protocol Nov 26 2003 5 PRELIMINARY 1 2 Access with Special Software Binary Interface The protocol of the binary data transfer is similar to the TFTP trivial file transfer protocol It is possible to read all and write change some data items Some items are stored in the power supply flash ROM other items are stored in the fan tray EEPROM Overview of the items Short Name Description Readable Writable Status Bit field on off voltage ok current ok yes No Control Switch on off change nominal fan speed no Yes UI Measured voltages currents yes No Temp Measured temperatures yes No Fan Real fan speed of all fans yes No Vers Data protocol version number yes No VersFan F
4. tocol Port Reference Comments ARP RFC 826 IP ICMP ECHO REC 792 IP TCP TELNET 23 RFC 854 Connection to the RS232 port only IP TCP HTTP 80 RFC 1945 WWW Interface IP TCP 69 wiener Special protocol to access all data Nov 26 2003 3 PRELIMINARY 1 1 Access with an Internet Browser WWW Interface You can access the crate with any internet browser we have tested Microsoft Internet Explorer Netscape Communicator and Linux Konqueror Open the connection by typing the address http IP OF THE CRATE there IP OF THE CRATE is the IP address of the crate default 192 168 91 80 Then the following page is opened UEP6000 PL500 Microsoft Internet Explorer UEP6000 PL500 W IE NE R Nov 26 2003 4 PRELIMINARY The vivible items are Item Description Changable Button ON Switch the crate on or off WWwW BINARY Button SYSRESET Generation of VME SYSRESET WWW BINARY Button FAN FASTER Fan speed change WWW BINARY Button FAN SLOWER Fan speed change WWW BINARY Power Supply Status OK or failure message Fan Tray Status OK or failure message Fan Speed Middle fan speed of all fan tray fans Air Temperature Inlet temperature of the fan tray Column Channel The number of the output channel related to the type label U0 U7 Column Name Alphanumeric name of the c

Download Pdf Manuals

image

Related Search

Related Contents

Catalogue Jouets 2015  User Guide - Mobiletech Blog  User Manual - Pro Light Japan    Ohlins SHOCK ABSORBERS MOTORCYCLE ROAD & TRACK User's Manual    Graco ISPP077AA User's Manual  Was ist Brother Web Connect?  Biostar TA870+ motherboard  

Copyright © All rights reserved.
Failed to retrieve file