Home

ZGL 62 Gas hob Instruction booklet GB

image

Contents

1. ON OFF SWITCH ZANUSSI Fitting the Hob into the Worktop Carry out the building in of the hob as follows js The edge of the hob forms a double seal which prevents the ingress of place the hob in the cut out taking fix the hob with the relevant fixing put the seals supplied with the hob on the edges of the cut out taking care that the seals meet without overlapping care that it is centred clamps and screws as shown in the diagram When the screws have been tightened the excess seal can be removed liquids ZANUSSI Electrical Connections AN Any electrical work required to install this hob should be carried out by a qualified electrician or competent person in accordance with the current regulations THIS HOB MUST BE EARTHED Electrical Requirements Any permanent electrical installation must comply with the latest I E E Hegulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC The manufacturer declines any liability should these safety measures not be observed This hob is designed to be connected to a 230 V 50 Hz AC electrical supply Before switching on make sure the electricity supply voltage is the same as that indicated on the hob ra
2. bet kir lyn tja 87 Vennootsweg 1 2404 CG Alphen aan den Rijn Risl kkvn 2 0508 Oslo Herziggasse 9 1230 Wien ul Kolejowa 5 7 Warszawa Quinta da Fonte Edificio Gon alves Zarco Q 35 2774 518 Pa o de Arcos Str Garii Progresului 2 S4 040671 RO Industriestrasse 10 CH 5506 M genwil Gerbi eva ulica 98 1000 Ljubljana Electrolux Slovakia s r o Electrolux Dom ce spotrebi e SK Seberiniho 1 821 03 Bratislava Electrolux Service S t G ransgatan 143 S 105 45 Stockholm Tarlaba caddesi no 35 Taksim stanbul 129090 Mocxea Onnmnn ckn npocnexr 16 BL Onumnuk ES ZANUSSI SS ZANUSSI www electrolux com www zanussi electrolux co uk 35687 8005 01 08 RA
3. it is necessary that you install a double pole switch between the hob and the electricity supply mains with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations The switch must not break the yellow and green earth cable at any point A Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 50 deg C Wiring diagram L 1 TAPS IGNITOR SWITCHES 2 IGNITOR UNIT 21 Fault Finding ZANUSSI Preliminary Electrical Systems Check START Isolate appliance and carry out A Earth Continuity check NO YES Yellow Has inlet fuse blown NO Inlet wiring faulty Rectify any fault Carry out C Polarity check Carry out D Resistance to Earth check YES Electricity supply should now be satisfactory PLUG with cover removed SOCKET face view Earth Wire Green Yellow es us Neutral Wire Blue carry out 22 Isolate appliance and B Insulation check Rectify any fault including replacing fuses as necessary A EARTH CONTINUITY CHECK Appliance must be electrically disconnected meter set on W Ohms x 1 scale and adjust zero if necessary Test leads from any appliance earth point to earth pin on plug Resistance should be le
4. Fault RINGING iren a aa ai ii 22 COMMISSIONIBG a stron E a ann edere ape RSA 25 Conversion from Natural Gas to LPG ooooooococcccnncnnncnnnnnnnnnnnonininininininos 26 Guide to Use the instructions The following symbols will be found in the text to guide you throughout the Instructions AN Safety Instructions qa Step by step instructions for an operation i Hints and Tips Environmental information MANUFACTURER ELECTROLUX HOME PRODUCTS ITALY S P A Viale Bologna 298 47100 Forli Italy ZANUSSI Important Safety Information You MUST read these warnings carefully before installing or using the hob If you need assistance contact our Customer Care Department on 08705 727 727 Installation This appliance must be installed and serviced by a competent person as stated in the Gas Safety Installation and Use Regulations Current Editions and the IEE Wiring Regulations For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installations 1 5 813 Current Editions and the ETC Rules for Electrical Installations Remove all packaging before using the hob Ensure that the gas and electrical supply complies with the type stated on the rating plate located near the gas supply pipe Do not attempt to modify the hob in any way People Safety This hob is designed to be operated by adults Do not allow children to play near or with the hob This appliance is not intended for use by chil
5. need to give the following details 1 Your name address and postcode 2 Your telephone number 3 Clear concise details of the fault 4 The model and Serial number of the appliance found on the rating plate 5 The purchase date Please note a valid purchase receipt or guarantee documentation is required for in guarantee service calls Customer Care For general enquiries concerning your Electrolux appliance or for further information on Electrolux products please contact our Customer Care Department by letter or telephone at the address below or visit our website at www electrolux co uk Customer Care Department Electrolux Major Appliances Addington Way Luton Bedfordshire LU4 9QQ Tel 08705 727 727 Calls may be recorded for training purposes 28 ZANUSSI European Guarantee This appliance is guaranteed by Electrolux in each of the countries listed at the back of this user manual for the period specified in the appliance guarantee or otherwise by law If you move from one of these countries to another of the countries listed below the appliance guarantee will move with you subject to the following qualifications The appliance guarantee starts from the date you first purchased the appliance which will be evidenced by production of a valid purchase document issued by the seller of the appliance The appliance guarantee is for the same period and to the same extent for labour and parts as exists in your new c
6. relevant control knob anti clockwise to maximum position and keep it pushed down about 5 seconds This will allow the thermocouple see Fig 1 lett D to be heated and the safety device to be switched off otherwise the gas supply would be interrupted Then check that the flame is regular adjust it as required To put the flame out turn the knob to the symbol If the burner does not ignite turn the control knob to zero and try again If you cannot light the flame even after severalattempts check the cap Fig 1 lett A and the crown Fig 1 lett B are in the correct position When switching on the mains after installation or a power cut it is quite normal for the spark generator to be activated A Burner cap Fig 1 automatically B Burner crown In the absence of electricity ignition gnition electrode can occur without the Becta Ges icc ee Cae this case approach the burner with a flame push the relevant knob down and turn it anti clockwise until it reaches the maximum position Do not keep the control knob pressed for more than 15 seconds If the burner does not light even after 15 seconds release the control knob turn it the off position and wait for at least one minute before trying to light the burner again If the burner accidentally goes out turn the control knob to the off position and wait for at least 1 minute before trying to light the burner again ZANUSS
7. serviced maintained repaired taken apart or tam pered with by any person not authorised by us Electrolux Service Force Centre must undertake all service work under this guaran tee Any appliance or defective part replaced shall become the Company s property This guarantee is in addition to your statutory and other legal rights Exclusions Damage or calls resulting from transportation improper use or neglect the re placement of any light bulbs or removable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of Electrolux manufacturer that are not marketed by Electrolux 27 Service and Spare Parts In the event of your appliance requiring service or if you wish to purchase spare parts please contact your local Service Force Centre by telephoning 0870 5 929 929 Your telephone call will be automatically routed to the Service Force Centre covering your postcode area For the address of your local Service Force Centre and further information about Service Force please visit the website at www serviceforce co uk Before calling out an engineer please ensure you have read the details under the heading Something not working When you contact the Service Force Centre you will
8. I Using the hob correctly To ensure maximum burner efficiency it is strongly recommended that you use only pots and pans with a flat bottom fitting the size of the burner used so that flame will not spread beyond the bottom of the vessel see the table below Pee gt OP pe gt Burner minimum maximum diameter diameter Large rapid 180 mm 260 mm Medium semi rapid 120 mm 220 mm Small auxiliary 80 mm 160 mm As soon as a liquid starts boiling turn down the flame so that it will barely keep the liquid simmering Use only pans or pots with flat bottom If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to overheat Carefully supervise cooking with fat or oil since these types of foodstuff can result in a fire if over heated The stainless steel can become tarnished if excessively heated Therefore prolonged cooking with potstones earthenware pans or cast iron plates is inadvisable Also do not use aluminium foil to protect the top during use Make sure pots do not protrude over the edges of the cooktop and that they are centrally positioned on the rings in order to obtain lower gas consumption Do not place unstable or deformed pots on the rings they could tip over or spill their contents causing accidents Pots must not enter the control zone If the control knobs become difficult to turn please contact your
9. SSI Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to R 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak test is carried out on the hob and installation Ensure that the main connection pipe does not exert any strain on the hob It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas ZANUSSI Building In Building over a cupboard or drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface It is also recommended to carry out the electrical connection to the hob as shown in diagrams 1 and 2 Building over a kitchen unit with door Proper arrangements must be taken in designing the furniture unit in order to avoid any contact with the bottom of the hob which can be heated when it is operated The recommended solution is shown in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections ON OFF SWITCH Dimensions are given in mm
10. This hob must be installed in accordance with the Gas Safety Installation and Use Regulations Current Edition and the IEE Wiring Regulations Current Edition For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Editions and the ETCI Rules for Electrical Installations Provision for Ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice B S 6172 B S 5440 Par 2 and B S 6891 Current Editions The hob should not be installed in a bed sitting room with a volume of less than 20 nf If it is installed in a room of volume less than 5 m an air vent of effective area of 100 cm is required If it is installed in a room of volume between 5 m and 10 m an air vent of effective area of 50 cm is required while if the volume exceeds 11 m no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m and 11 m If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements For appliances installed in the Republic of Ireland please refer to the NSAI Domestic Gas Installation I S 813 Current Editions Table Four Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room E
11. ZANUSSI gt 4 Instruction booklet P q 4 4 Gas hob 4 ZGL 62 E ZANUSSI Thank you for selecting our appliance We wish you lots of enjoyment with your new appliance and we hope that you will consider our brand again when purchasing household appliances Please read this user manual carefully and keep it throughout the product life cycle as a reference document The user manual should be passed on to any future owner of the appliance ZANUSSI Contents Important Safety Information 4 Description Of the HOB s issue coca ratto n er t b gg a a Ra a gada an ie 6 Instructions Tor the Us ais minette 7 PE DR asian AA aa aa kae der eee tete daa 8 Maintenance and Cleaning cccccccncnnncnnnnnnononnnannninnninaninininnnananinnnnns 10 Something Not Working si 12 Guarantee Customer Service ss 27 European Guarantee iii 29 Instructions for the Installer 13 Engineer technical data 13 Important safety requirements 15 LOCATION PE 15 AREE IELO III LEE 16 Gas COMEN sss eos teo errata Y cute teg e Na ga A S 17 SNe RISIN AEE EE E E E ira tet street o teres 18 Building over a cupboard or drawer seer aaa eaaa zima 18 Building over a kitchen unit with door coocccccccccccccccccconicnnnnanananana nino 18 Fitting the Hob into the Worktop 19 Electrical Connections 20 AMM UI aga cds AA AAA AAA WAA AA EE 21
12. ances ensure the cable does not come into contact with the hot surfaces of the cooking appliance e Unstable or misshapen pans should not be used on the hob as unstable pans can cause an accident by tipping or spillage e Never leave the hob unattended when cooking with oil and fats e Never use plastic or aluminium foil dishes on the hob e Perishable food plastic items and areosols may be affected by heat and should not be stored above or below the hob unit e This appliance cannot be cleaned with steam or with a steam cleaning machine Service e This hob should only be repaired or serviced by an authorised Service Engineer and only genuine approved spare parts should be used Environmental Information e After installation please dispose of the packaging with due regard to safety and the environment e When disposing of an old appliance make it unusable by cutting off the cable e The symbol A o the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city o
13. be undertaken by a competent person Itis important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjusted to suit Method cge 1 Ensure that the gas taps are in the OFF position 2 Isolate the hob from the electricity supply 3 Remove all pan supports burner caps rings crowns and control knobs 4 With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors TO ADJUST THE GAS RATE With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw Upon completion stick the replacement rating plate on the under side of the hob 26 ZANUSSI Guarantee Customer Service Standard guarantee conditions We Zanussi Electrolux undertake that if within 12 months ofthe date ofthe purchase this Zanussi Electrolux appliance or any part thereof is proved to be defective by reason only of faulty workmanship or materials we will at our option repair or replace the same FREE OF CHARGE for labour materials or carriage on condition that The appliance has been correctly installed and used only on the electricity supply stated on the rating plate The appliance has been used for normal domestic purposes only and in accord ance with the manufacturer s instructions The appliance has not been
14. dren or other persons whose physical sensory or mental capabilities or lack of experience and knowledge prevents them from using the appliance safely without supervision or instruction by a responsible person to ensure that they can use the appliance safely The hob gets hot when it is in use Children should be kept away until it has cooled Children can also injure themselves by pulling pans or pots off the hob During Use This hob is intended for domestic cooking only It is not designed for commercial or industrial purposes This appliance is not connected to a combustion products evacuation device It must be installed and connected in accordance with current installation regulations Particular attention shall be given to the relevant requirements regarding ventilation When in use a gas cooking hob will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose Ensure a good ventilation around the appliance A poor air supply could cause lack of oxygen ZANUSSI e When using the hob for a long period time the ventilation should be improved by opening a window or increasing the extractor speed e Do not use this hob if it is in contact with water Do not operate the hob with wet hands e Ensure the control knobs are in the OFF position when not in use e When using other electrical appli
15. ffice your household waste disposal service or the shop where you purchased the product These instructions are only valid for countries whose identification symbols are shown on the cover of this instruction booklet and on the appliance itself Keep this instruction book for future reference and ensure it is passed on to any new owner Description of the Hob ZANUSSI 1 Hob Top 2 Rapid Burner 3 Semi rapid Burner 4 Auxiliary Burner 5 Control knobs ZANUSSI Instructions for the User AN INSTALLATION Any gas installation must be carried out by a registered competent person and in accordance with existing rules and regulations The relevant instructions are to be found in the second section of this manual Please ensure that once the hob is installed it is easily accessible for the engineer in the event of a breakdown WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed it is important to remove any protective materials which were put on in the factory The manufacturer will not accept liability should the above instructions or any of the other safety instructions incorporated in this book be ignored ZANUSSI Operation Lighting the burners For easier lighting proceed before putting a pan on the pan support gt To light a burner Turn the relevant knob anti clockwise to maximum position AQ then push it down to ignite the burner Only for Model ZGL62 IT turn the
16. in the mains connector block and the insulation of the HT leads taps ignition switches Check continuity from ignition Change the ignitor unit switches connector to ignitor unit 24 Commissioning ZANUSSI When the hob has been fully installed it will be necessary to check the minimum flame setting To do this follow the procedure below cg 1 Turn the gas tap to the MAX position and ignite 2 Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times If the flame is unstable or is extinguished follow the procedure below Procedure 1 Re ignite the burner and set to MIN 2 Remove the control knob 3 To adjust use a thin bladed screwdriver and turn the adjustment screw see diagram until the flame is steady and does not extinguish when the knob is turned from MIN to MAX Repeat this procedure for all burners Pressure Testing Minimum adjustment screw The pressure testing must be carried out on the burners gt Proceed as follows 1 Remove the pan supports and the burner caps and crowns 2 Fit manometer tube over the injector 3 Turn on the burner gas supply and ignite another burner supply The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar 4 Turn off the burner supplies 25 ZANUSSI Conversion from Natural Gas to LPG AN IMPORTANT The replacement conversion from natural gas to LPG should only
17. ld paste cleaner A well moistened soap impregnated steel wool pad can be used with caution if the marks are particularly difficult to remove After cleaning be sure to wipe dry with a soft cloth ZANUSSI The Ignition electrode The electric ignition is obtained through a ceramic electrode which contains a metal electrode Fig 1 C Keep these components very clean to avoid difficult lighting and check that the burner crown holes Fig 1 B are not obstructed Something Not Working ZANUSSI If the hob is not working correctly please carry out the following checks before contacting your local Service Force Centre SYMPTOM There is no spark when lighting the gas The gas ring burns unevenly SOLUTION Check that the unit is plugged in and the electrical supply is switched on Check that the RCCB has not tripped if fitted Check the mains fuse has not blown Check the burner cap and crown have been replaced correctly e g after cleaning Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown have been replaced correctly e g after cleaning If after all these checks your hob still does not operate correctly contact your local Service Force Centre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee customers should ensure that the above checks have been
18. local Service Force Centre ZANUSSI AN Before any maintenance or cleaning can be carried out you must DISCONNECT the hob from the electricity supply A The hob is best cleaned whilst it is still warm as spillage can be removed more easily than if it is left to cool AN This appliance cannot be cleaned with steam or with a steam cleaning machine The Hob Top Regularly wipe over the hob top using a soft cloth well wrung out in warm water to which a little wasing up liquid has been added Avoid the use of the following household detergent and bleaches impregnated pads unsuitable for non stick saucepans steel wool pads bath sink stain removers Should the hob top become heavily soiled the following products are recommended For stainless steel hobs use a proprietary stainless steel cleaner For other hobs use Hob Brite or Bar Keepers Friend Do not leave acid or alkaline substances e g vinegar salt lemon juice etc on the cooktop Pan Supports The pan supports are dishwasher proof If washing them by hand take care when drying them as the enamelling process occasionally leaves rough edges If necessay remove stubborn stains using a paste cleaner After cleaning make sure that the pan supports are correctly positioned Maintenance and Cleaning The Burners The burner caps and crowns can be removed for cleaning Wash the burners caps and crowns using hot soapy water and remove marks with a mi
19. made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown ZANUSSI Instructions for the Installer Engineer technical data OVERALL DIMENSIONS Width 580 mm Depth 500 mm CUT OUT DIMENSIONS Width 550 mm Depth 470 mm Thickness 30mm SUPPLY CONNECTIONS Gas R 1 2 inch 1 2 inch male Rear right hand corner Electric 230 V 50 Hz supply 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse HEAT INPUT Rear Left Burner 2 0 KW 6826 BTU HR semi rapid Front Left Burner 3 0 kW Natural Gas 10239 BTU HR rapid 2 8 KW L P G 9556 BTU HR Rear Right Burner 2 0 KW 6826 BTU HR semi rapid Front Right Burner 1 0 KW 3413 BTU HR auxiliary APPLIANCE CLASS 3 APPLIANCE CATEGORY 112H3 GAS SUPPLY Natural gas G20 2H 20 mbar This appliance is manufactured according to the following EEC directives 2006 95 EEC 93 68 EEC 89 336 EEC 90 396 EEC current edition ZANUSSI RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m h 0 286 37 78 MJ n Ws 50 7 MJ m 20 mbar NOZZLEREFERENCE 1 100 mm o lt o zi E 2 E lt z VALUE NOMINAL THERMAL POWER kw NOMINAL FLOW RATE g h 49 92 MJ Kg LPG GAS 28 30 37 mbar NOZZLE REFERENCE 1 100 mm VALUE 14 ZANUSSI Important safety requirements
20. nsure that there is a minimum distance of 55 mm between the rear cut out edge and the wall A minimum distance of 100 mm must be left between the side edges of the cut out and any adjacent cabinets or walls The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm If it is fitted below 400 mm a space of 50 mm must be allowed from the edges of the hob ZANUSSI The minimum distance combustible material or a cooker hood can be fitted above the hob is 650 mm For appliances installed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Edition Section 7 Permitted Locations of Appliance Installation IMPORTANT AN This hob must be installed by a competent person to the A relevant Gas Standards Any gas installation must be carried out by a registered competent person Please ensure that once the hob is installed it is easily accessible for the engineer in the event of a breakdown The manufacturer will not accept liability should the above instructions or any of the other safety instructions incorporated in this instruction booklet be ignored On the end of the shaft which includes the G 1 2 threaded elbow adjustment is fixed so that the washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force A End of shaft with nut B Washer C Elbow ZANU
21. ountry of residence for this particular model or range of appliances The appliance guarantee is personal to the original purchaser of the appliance and cannot be transferred to another user The appliance is installed and used in accordance with instructions issued by Electrolux and is only used within the home i e is not used for commercial purposes The appliance is installed in accordance with all relevant regulations in force within your new country of residence The provisions of this European Guarantee do not affect any of the rights granted to you by law 29 O Albania Belgique Belgi Belgien 30 ZANUSSI www electrolux com www electrolux fr 44 8705 929 929 30 23 10 56 19 70 385 1 63 23 338 353 1 40 90 753 35 12 14 40 39 39 40 21 451 20 30 41 62 88 99 111 38 61 24 25 731 421 2 43 33 43 22 www electrolux fi 46 0 771 76 76 76 E Rr Pjeter Bogdani Nr 7 Tirane Bergensesteenweg 719 1502 Lembeek Bud jovick 3 Praha 4 140 21 Sj llandsgade 2 7000 Fredericia Muggenhofer Str 135 90429 N rnberg P rnu mnt 153 11624 Tallinn Carretera M 300 Km 29 900 Alcal de Henares Madrid Addington Way Luton Bedfordshire LU4 9QQ 4 Limnou Str 54627 Thessaloniki Slavonska avenija 3 10000 Zagreb Long Mile Road Dublin 12 C so Lino Zanussi 26 33080 Porcia PN Kr Barona iela 130 2 LV 1012 Riga Ozo 10A LT 08200 Vilnius Rue de Bitbourg 7 L 1273 Hamm H 1142 Budapest XIV Erzs
22. ss than 0 1 W Ohm check all earth wires for continuity and all contacts clean and tight B INSULATION CHECK Appliance electrically disconnected all switches ON a meter set on W Ohms x 1 scale Test leads from L to N in appliance terminal block If meter reads O then there is a short circuit b meter set on W Ohm x 100 scale Repeat test with leads from L to E If meter reads less than x infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evidence of burning around the fault 23 ZANUSSI Ignition System Gas Ignition YES Ignitor does not spark Check gas suppiyat burner NO Check plug top fuse and replace if necessary Light burner manually Check polarity and Check by pass simmer earth continuity of adjusted supply point Check fitting of burners Check position of the Check earth continuity electrode of appliance Check continuity from N on the Check continuity from the tip of mains connector block and O on each electrode to the terminals the ignitor unit 1 to 4 on the ignitor unit Check continuity from L on the Check for breaks
23. ting plate The rating plate is located on the bottom of the hob A copy is attached on the back cover of this book The hob is supplied with a 3 core flexible supply cord incorporating a 3 amp plug GREEN amp veLLow 3 AMP FUSE fitted In the event of having to change the fuse a 3 amp ASTA approved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live cg 1 Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black 3 Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red 20 ZANUSSI Upon completion there must be no cut or stray strands of wire present and the cord clamp must be secure over the outer sheath AN A cut off plug inserted into a 18 amp socket is a serious safety shock hazard Ensure that the cut off plug is disposed of safely AN The replacement of electric cable must be carried out ex clusively by the service force centre or by personnel with similar competencies in accordance with the current regu lations Permanent Connection In the case of a permanent connection

Download Pdf Manuals

image

Related Search

Related Contents

S Manual de Instrucciones  Empire Products RH-35-6 User's Manual  Decreto de Alcaldía  SECTION B1: MACHINE COMPONENTS    Bosch GST 75 BE  1.877.766.5412 - PowerMeterStore.com  OP184/OP284/OP484    User Manual and Step-by-Step Guide  

Copyright © All rights reserved.
Failed to retrieve file