1. USB1 USB2 Connector USB1 connector CN Type ITT Cannon KPT02A14 19S Conn Type Std USB A Socket Mating ITT Cannon KPT06J14 19P Mating Standard USB A connector Pin Signal Pin Signal A N C B USB1 5V 1 5 V C USB1 D 2 D D USB1 D 3 D E USB1 GND 4 GND F N C USB2 connector G N C Conn Type Std USB A Socket H N C Mating Standard USB A connector J N C Pin Signal K USB2 D 2 D L USB2 D 3 D M USB2 GND 4 GND N N C P N C R USB2 5V 1 5 V S N C T N C U N C V N C Please refer to Figure A 2 1 1 and Figure A 2 2 1 22 HAZARDOUS Interconnect NON HAZARDOUS LAN Connector LAN connector CN Type ITT Cannon KPT02A12 8S CN Type Standard RJ 45 plug Mating ITT Cannon KPT06J12 8P Mating Standard RJ 45 socket Pin Signal Pin Signal A TD 1 TD B TD 2 TD C RD 6 RD D RD 3 RD E N C 4 N C F N C 5 N C G N C 7 N C H N C 8 N C Please refer to Figure A 2 1 2 and Figure A 2 2 3 HAZARDOUS Interconnect NON HAZARDOUS DC Power Input Connector B Harrison 1R5G06A20A120 24 VDC Power supply B Harrison 105000A02F060 Please refer to Figure A 2 1 5 and Figure A 2 2 4 Pin Signal Color Signal O Orange N C Orange N C B Black 24 VDC Black 24 VDC G Green Earth Ground Green Earth
2. USB SERIAL Connector USB connectors CN Type ITT Cannon KPT02A14 19S Conn Type Std USB A Socket Mating ITT Cannon KPT06J14 19P Mating Standard USB A connector Pin Signal Pin Signal A N C B USB1 5V 1 5 V E USB1 D 2 D D USB1 D 3 D E USB1 GND 4 GND RS 232 connector F N C CN Type Standard DB 9 male Mating Standard DB 9 female Pin Signal G RX COM1 2 A H TX COM1 3 TX J GND COM1 5 GND K N C L N C M N C N N C P N C R N C S N C T N C U N C V N C Please refer to Figure A 4 1 1 and Figure A 4 2 2 31 HAZARDOUS Interconnect NON HAZARDOUS LAN Connector 2800 LAN connector CN Type ITT Cannon KPT02A12 8S CN Type Standard RJ 45 plug Mating ITT Cannon KPT06J12 8P Mating Standard RJ 45 socket Pin Signal Pin Signal A TD 1 TD B TD 2 TD C RD 6 RD D RD 3 RD E N C 4 N C F N C 5 N C G N C 7 N C H N C 8 N C Please refer to Figure A 4 1 2 and Figure A 4 2 3 HAZARDOUS Interconnect NON HAZARDOUS DC Power Input Connector B Harrison 1R5G06A20A120 24 VDC Power supply B Harrison 105000A02F060 Please refer to Figure A 4 1 4 and Figure A 4 2 4 Pin Signal Color Signal O Orange N C Orange N C B Black 24 VDC Black 24 VDC G Green Earth Ground Green Earth Ground W White 24
3. Mating ITT Cannon KPT06J14 19P Mating Standard USB A connector Pin Signal Pin Signal A N C B USB1 5V 1 5 V C USB1 D 2 D D USB1 D 3 D E USB1 GND 4 GND F N C USB connectors G N C Conn Type Std USB A Socket H N C Mating Standard USB A connector J N C Pin Signal K USB2 D 2 D L USB2 D 3 D M USB2 GND 4 GND N N C P N C R USB2 5V 1 5 V S N C T N C U N C V N C Please refer to Figure A 5 1 1 and Figure A 5 2 2 36 HAZARDOUS Interconnect NON HAZARDOUS LAN Connector 2800 LAN connector CN Type ITT Cannon KPT02A12 8S CN Type Standard RJ 45 plug Mating ITT Cannon KPT06J12 8P Mating Standard RJ 45 socket Pin Signal Pin Signal A TD 1 TD B TD 2 TD C RD 6 RD D RD 3 RD E N C 4 N C F N C 5 N C G N C 7 N C H N C 8 N C Please refer to Figure A 5 1 2 and Figure A 5 2 3 HAZARDOUS Interconnect NON HAZARDOUS AC Power Input Connector AC connector CN Type B Harrison 1R3GO06A20A120 Std NEMA L6 15 Plug Mating B Harrison 103000A01F060 Std NEMA L6 15 socket Pin Signal Pin Signal G Green Earth Ground G Earth Ground W White Neutral Y Neutral B Black Line X Line Please refer to Figure A 5 1 4 and Figure A 5 2 4 37 HAZARDOUS Interconnect NON HAZARDOUS Key
4. A 7 2 2 46 HAZARDOUS Interconnect NON HAZARDOUS LAN Connector 2800 LAN connector CN Type ITT Cannon KPT02A12 8S CN Type Standard RJ 45 plug Mating ITT Cannon KPT06J12 8P Mating Standard RJ 45 socket Pin Signal Pin Signal A TD 1 TD B TD 2 TD C RD 6 RD D RD 3 RD E N C 4 N C F N C 5 N C G N C 7 N C H N C 8 N C Please refer to Figure A 7 1 2 and Figure A 7 2 3 HAZARDOUS Interconnect NON HAZARDOUS AC Power Input Connector AC connector CN Type B Harrison 1R3GO06A20A120 CN Type Std NEMA L6 15 Plug Mating B Harrison 103000A01F060 Mating Std NEMA L6 15 socket Pin Signal Pin Signal G Green Earth Ground G Earth Ground W White Neutral Y Neutral B Black Line X Line Please refer to Figure A 7 1 4 and Figure A 7 2 4 47 HAZARDOUS Interconnect NON HAZARDOUS Keyboard connector Keyboard connector CN Type ITT Cannon KPT02A10 6S CN Type _ Std PS2 female connector Mating ITT Cannon KPT06J10 6P Mating Std PS2 male connector Pin Signal Pin Signal A KBD CLK 5 keyboard KBD CLK B KBD DATA 1 keyboard KBD DATA G KBD 5V 4 kb m KBD 5V D KBD GND 3 kb m KBD GND E MOUSE CLK 5 mouse MOUSE CLK F MOUSE DATA 1 mouse MOUSE DATA Please refer to Figure A 7 1 3 and Figure A 7 2 1
5. DATA 1 KBD DATA G KBD 5V 4 KBD 5V D KBD GND 3 KBD GND E N C F N C Please refer to Figure A 6 1 3 and Figure A 6 2 1 43 A 6 1 Drawing Back connectors MODEL 2800 AC M5 Uk B F E E D CDE Figure A 6 1 1 Figure A 6 1 2 Figure A 6 1 3 COM1 USB1 USB2 LAN connector Keyboard connector connector Figure A 6 1 4 AC power input connector 44 A 6 2 Drawing Cables for Non Hazardous location MODEL 2800 AC M5 Mates to keyboard PS2 female connector on 2800 keyboard Figure A 6 2 1 Mates to COM 1 USB 1 USB 2 connector on 2800 Figure A 6 2 2 Mates to LAN E a connector RJ 49 plug on 2800 Figure A 6 2 3 Mates to AC input NEMA 5 15 power connector on 2800 Figure A 6 2 4 45 A 7 2800 AC M6 MODEL HAZARDOUS Interconnect NON HAZARDOUS USB SERIAL Connector USB connectors CN Type ITT Cannon KPT02A14 19S Conn Type Std USB A Socket Mating ITT Cannon KPT06J14 19P Mating Standard USB A connector Pin Signal Pin Signal A N C B USB1 5V 1 5 V C USB1 D 2 D D USB1 D 3 D E USB1 GND 4 GND RS 232 connector F N C CN Type Standard DB 9 male Mating Standard DB 9 female Pin Signal G RX COM 2 RX H TX COM 3 TX J GND COM1 5 GND K N C L N C M N C N N C P N C R N C S N C T N C U N C V N C Please refer to Figure A 7 1 1 and Figure
6. F CAUTION The Internal lithium battery on the CPU board must be replaced with a 3 vok 20mm size tum battery only CAUTION Keop cover tight while circuits or heater CAUTION Please refer to the Users Manual for installation instructions and a list of approved equipment that may be connected to this unit Connecting equipment tha is rot on the approved it may impair the Hazardous Location designation of this unit WARNING Substtution of components l strictly prohibited MARINO DO NOT GONIEC OR DISCONNECT ANY CONNECTOR MEN ENERGIZED C PONER INPUT VOC LANS POWER FORALL RUT EXCEPT HEATERS Figure 1 1 o O HEATERS PHOTOSENSOR WARNING DO NOT CONNECT OR ISCONNECT ANY CONNECTOR WHEN ENERGIZED ont use CHEN SECTION 2 SAFETY KE The following safety instructions must be followed to prevent possible hazards of fire electrical shock and bodily harm 1 10 11 WARNING The model 2800 must be connected to an appropriate power source as indicated on the information label on the rear panel of the unit WARNING AC Units The circuit breaker for the power connection on the rear panel of the unit must be in the OFF position such that the internal circuits are not energized whenever the power source is either connected or disconnected from the unit WARNING DC Units The circuit breaker for the power connection on the rear panel of the unit must be in the OFF position such that the internal circuits ar
7. power source The termination on the end of the power cable marked must be connected to positive output of the 24 VDC power source The termination on the end of the power cable marked must be connected to negative output of the 24 VDC power source The termination on the end of the power cable marked E must be connected to Earth Ground The LAN cable is terminated in a standard RJ 45 plug which must be connected to any 10 100 M bit Ethernet LAN device that adheres to the IEEE 802 3 standard The Keyboard cable is terminated in a standard PS2 female connector that may be connected to any standard PS2 keyboard The Serial USB cable is split up into 3 separate terminations The terminations labeled COM1 COM provide a DB 9 male connector which may be connected to any ELA RS 232C connection The terminations labeled USB1 USB2 provides a Type A Jack 4 position which may be connected to any device with the USB standard due to the safety barriers the USB can only support full speed standard USB 1 1 and since they are current limited it is recommended to use externally powered devices when possible The drawings and pin outs of these cables are provided in Appendix B 3 3 2 Hazardous locations The user is required to provide all the external cables for use in hazardous locations The cabling and connection methods and restrictions are detailed below The Control Drawing for all connections to the 28
8. 00 is shown in Figure A 1 1 AC Power cable The pin out for the AC POWER INPUT connector on the rear panel of the 2800 is provided in Appendix A The mating connector is also listed in Appendix A The External 110 VAC 60Hz or 220 VAC 50 Hz power source must be located in a non hazardous location 2 DC Power cable The pin out for the DC POWER INPUT connector on the rear panel of the 2800 is provided in Appendix A The mating connector is also listed in Appendix A The External 24 VDC 2 VDC power source must be located in a non hazardous location WARNING The power cord used must adhere to the following rules a The power cord must be approved for extra hard usage b Thesection of the power cord that runs through a hazardous area must be protected by rigid conduit with liquid tight ends c Only the last 3 feet before the power cord mates to the 2800 may be left unprotected without the rigid conduit d The power cord must be terminated into the external AC or DC power source as shown in Figure A 1 WARNING Make sure that the POWER circuit breaker on the rear panel of the 2800 is in the OFF position before connecting or disconnecting the POWER INPUT connector Do not connect or disconnect the POWER INPUT connector when the circuits are energized WARNING Ensure that the external power source is OFF before connecting or disconnecting the POWER INPUT connector 3 LAN cable The pin out for the LAN connector on the
9. 1 3 3 Connections to the 2800 There is a significant difference on how connections may be made to the 2800 based on whether the location of use is hazardous or non hazardous 3 3 1 Non hazardous locations The unit is provided with external cables according to the model option refer to Table 3 3 1 a 2800 Models CABLES PROVIDED 2800 AC Rev D Standard AC POWER RS 232 2 USB KEYBOARD a 2800 AC M2 Rev B AC POWER USB LAN KB MOUSE b 2800 AC M5 Rev A AC POWER RS 232 2 USB KEYBOARD c 2800 AC M6 Rev B 2800 ACW Rev B Standard AC POWER AC POWER RS 232 USB RS 232 2 USB KB WITH STAND KEYBOARD a 2800 ACW M4 Rev B AC POWER 2 USB KEYBOARD b 2800 ACW M7 Rev B 2800 DC Rev D Standard AC POWER DC POWER USB RS 232 RS 422 XDR RS 232 2 USB KEYBOARD KEYBOARD a 2800 DC M1 Rev B DC POWER 2 USB KEYBOARD b 2800 DC M3 Rev B 2800 DCW Rev B Standard DC POWER DC POWER RS 232 USB RS 232 2 USB STAND ALONE KB KEYBOARD Table 3 3 1 a WARNING All the above cables are for use in non hazardous locations only Using these cables in hazardous locations may impair the hazardous location classification of the unit The AC power cable is terminated in a NEMA 5 15 plug and may only be connected to a power source of 110 220 VAC 50 60 Hz The DC power cable must be connected to an external 24 Volts 2 volts DC
10. 48 A 7 1 Drawing Back connectors MODEL 2800 AC M6 Uk B F E TEC D CDE Figure A 7 1 1 Figure A 7 1 2 Figure A 7 1 3 COM1 USB1 USB2 LAN connector Keyboard connector connector Figure A 7 1 4 AC power input connector 49 A 7 2 Drawing Cables for Non Hazardous location MODEL 2800 AC M6 Stand Alone Keyboard Mates to kb mouse connector on 2800 Figure A 7 2 1 DB 9 male Mates to COM1 USB 1 connector on 2800 Figure A 7 2 2 Mates to LAN E connector RAS plug on 2800 Figure A 7 2 3 Mates to AC input NEMA 5 15 power connector on 2800 Figure A 7 2 4 50 A 8 2800 AC M7 MODEL HAZARDOUS Interconnect NON HAZARDOUS USB SERIAL Connector USB connectors CN Type ITT Cannon KPT02A14 19S CN Type Sid USB A Socket Mating ITT Cannon KPT06J14 19P Mating Standard USB A connector Pin Signal Pin Signal A N C B USB4 5V 1 aV C USB4 D 2 D D USB4 D 3 D E USB4 GND 4 GND RS 232 connector F N C CN Type Standard DB 9 male Mating Standard DB 9 female Pin Signal G RX__ COM2 2 Rs H TX COM2 3 TX J GND COM2 5 GND RS 422 connector K N C CN Type KPTO1F12 108 Mating KPT06J12 10P Pin 4 Signal L RS422 TX 4 TX M RS422 TX 5 IX N RS422 RX 1 RX P RS422 RX 2 RX Transducer connector R N C ITT Cannon KPT01A10 6P I
11. G Green Earth Ground G Earth Ground W White Neutral Y Neutral B Black Line X Line Please refer to Figure A 1 1 4 and Figure A 1 2 5 HAZARDOUS Interconnect NON HAZARDOUS Keyboard connector Keyboard connector CN Type ITT Cannon KPT02A10 6S CN Type _ Std PS2 female connector Mating ITT Cannon KPT06J10 6P Mating Std PS2 male connector A KBD GLK 5 KBD CLK B KBD DATA 1 KBD DATA G KBD 5V 4 KBD 5V D KBD GND 3 KBD GND E N C F N C Please refer to Figure A1 1 3 and Figure A 1 2 1 19 Figure A 1 1 1 COM1 USB1 USB2 connector A 1 1 Drawing Back connectors MODEL 2800 STANDARD B F B F c E D CDE Figure A 1 1 2 Figure A 1 1 3 LAN connector Keyboard connector Figure A 1 1 4 Figure A 1 1 5 AC power input DC power input connector connector 20 A 1 2 Drawing Cables for Non Hazardous location MODEL 2800 STANDARD HAZARDOUS NON HAZARDOUS Mates to keyboard connector on 2800 Mates to COM 1 USB 1 USB 2 connector on 2800 Mates to LAN connector on 2800 Mates to DC input power connector on 2800 Mates to AC input power connector on 2800 PS2 female keyboard Figure A 1 2 1 DB 9 male COM 1 Figure A 1 2 2 RJ 45 plug Figure A 1 2 3 NEMA 5 15 Figure A 1 2 5 21 A 2 MODEL 2800 DC M1 HAZARDOUS Interconnect NON HAZARDOUS
12. Ground W White 24 VDC Return White 24 VDC return R Red N C Red N C Note Pins are not marked on the DC connector The pin numbers shown indicate the wire color used for each pin internally HAZARDOUS Interconnect NON HAZARDOUS AC Power Input Connector AC connector CN Type B Harrison 1R3GO0O6A20A120 CN Type Std NEMA L6 15 Plug Mating B Harrison 103000A01F060 Mating Std NEMA L6 15 socket Pin Signal Pin 4 Signal G Green Earth Ground G Earth Ground W White Neutral Y Neutral B Black Line X Line Please refer to Figure A 2 1 4 and Figure A 2 2 5 HAZARDOUS Interconnect NON HAZARDOUS Keyboard connector Keyboard connector CN Type ITT Cannon KPT02A10 6S CN Type _ Std PS2 female connector Mating ITT Cannon KPT06J10 6P Mating Std PS2 male connector A KBD CLK 5 KBD CLK B KBD DATA 1 KBD DATA G KBD 5V 4 KBD 5V D KBD GND 3 KBD GND E N C F N C Please refer to Figure A 2 1 3 and Figure A 2 2 1 24 Figure A 2 1 1 COM1 USB1 USB2 connector A 2 1 Drawing Back connectors MODEL 2800 DC M1 B F E 3 D CDE Figure A 2 1 2 Figure A 2 1 3 LAN connector Keyboard connector Figure A 2 1 4 Figure A 2 1 5 AC power input DC power input connector connector 25 A 2 2 Drawing Cables for Non Hazardous location MODEL 2800 DC M1 HAZARDOUS NON HAZARDOUS Mates to keyboard connec
13. JA AVERSAB MODEL 2800 USER S MANUAL LAVERSAB INC 505 Gillingham Lane Sugar Land TX 77478 281 325 8300 FAX 281 328 8399 Email oservice laversab com Document Number 9032 Date Oct 10 2011 WARRANTY Laversab Inc warrants its products to conform to or exceed the specifications as set forth in its catalogs in use at the time of sale and reserves the right at its own discretion without notice and without making similar changes in articles previously manufactured to make changes in materials designs finish or specifications Laversab Inc warrants products of its own factory against defects of material or workmanship for a period of one year from date of sale Liability of Laversab Inc under this warranty shall be limited to replacing free of charge FOB Houston Texas any such parts proving defective within the period of this warranty but Laversab Inc will not be responsible for transportation charges consequential or incidental damages No liability is assumed by Laversab for damages that are caused by misuse or abuse of the product The warranty of Laversab Inc is not made for products manufactured by others which are illustrated and described in Laversab catalogs or incorporated in Laversab products in essentially the same form as supplied by the original manufacturer COPYRIGHT NOTICE Copyright c 2003 2007 by Laversab Inc All rights reserved The content of this manual may not be reproduced i
14. L 1604 CAN CSA C22 2 No 213 M1987 SECTION 3 INSTALLATION The installation process consists of a Loading the application software onto the 2800 b Mounting the 2800 on site using an appropriate mounting bracket c Making the connections to the 2800 3 1 Loading software The 2800 is provided with a Windows operating system that is pre installed with the network enabled All software must be loaded through the USB ports USB1 1 std It is not necessary to open the unit to load the software If software modifications require that the unit be opened to have access to internal connectors this must be done at the Laversab facility If the unit is opened by the user then it may severely impair the hazardous location classification of the unit 3 2 Mounting the 2800 A suitable mounting bracket may be fabricated by the user based on the user s mounting requirements Figure 3 1 shows a suggested mounting bracket for mounting the 2800 on a flat plate or on a pipe stand with an optional adapter The mounting bracket should be fastened to the four mounting studs provided on the rear panel of the unit The studs are inch in length with a thread size of 5 16 18 WARNING The mounting bracket should not cover any of the markings and warnings on the rear panel of the 2800 WARNING The mounting bracket should not cover any of the connectors or the circuit breakers on the rear panel of the 2800 WARNING The mounting bracket sho
15. SB2 D L USB2 D M USB2 GND N N C P N C R USB2 5V S N C T N C u N C V N C Please refer to Figure A 1 1 1 and Figure A 1 2 2 17 HAZARDOUS Interconnect NON HAZARDOUS LAN Connector 2800 LAN connector CN Type ITT Cannon KPT02A12 8S CN Type Standard RJ 45 plug Mating ITT Cannon KPT06J12 8P Mating Standard RJ 45 socket Pin Signal Pin Signal A TD 1 TD B TD 2 TD C RD 6 RD D RD 3 RD E N C 4 N C F N C 5 N C G N C 7 N C H N C 8 N C Please refer to Figure A 1 1 2 and Figure A 1 2 3 HAZARDOUS Interconnect NON HAZARDOUS DC Power Input Connector 24 VDC Power supply B Harrison 1R5G06A20A120 B Harrison 105000A02F060 Pin Signal Color Signal O Orange N C Orange N C B Black 24 VDC Black 24 VDC G Green Earth Ground Green Earth Ground W White 24 VDC Return White 24 VDC return R Red N C Red N C Please refer to Figure A 1 1 5 and Figure A1 2 4 Note Pins are not marked on the DC connector The pin numbers shown indicate the wire color used for each pin internally 18 HAZARDOUS Interconnect NON HAZARDOUS AC Power Input Connector AC connector CN Type B Harrison 1R3G06A20A120 CN Type Std NEMA L6 15 Plug Mating B Harrison 103000A01F060 Mating Std NEMA L6 15 socket Pin Signal Pin Signal
16. TT Cannon KPT02A10 6S Pin Signal S XDR V B XDR V T XDR GND F XDR GND U N C V XDR 24V A XDR 24V Please refer to Figure A 8 1 1 and Figure A 8 2 2 51 HAZARDOUS Interconnect NON HAZARDOUS LAN Connector 2800 LAN connector CN Type ITT Cannon KPT02A12 8S CN Type Standard RJ 45 plug Mating G ITT Cannon KPT06J12 8P Mating Standard RJ 45 socket Pin Signal Pin Signal A TD 1 TD B TD 2 TD C RD 6 RD D RD 3 RD E N C 4 N C F N C 5 N C G N C 7 N C H N C 8 N C Please refer to Figure A 8 1 2 and Figure A 8 2 3 HAZARDOUS Interconnect NON HAZARDOUS AC Power Input Connector AC connector CN Type B Harrison 1R3GO06A20A120 CN Type Std NEMA L6 15 Plug Mating B Harrison 103000A01F060 Mating Std NEMA L6 15 socket Pin Signal Pin Signal G Green Earth Ground G Earth Ground W White Neutral Y Neutral B Black Line X Line Please refer to Figure A 8 1 4 and Figure A 8 2 4 52 HAZARDOUS Interconnect NON HAZARDOUS Keyboard connector Keyboard connector CN Type ITT Cannon KPT02A10 6S CN Type _ Std PS2 female connector Mating ITT Cannon KPT06J10 6P Mating Std PS2 male connector A KBD CLK 5 KBD CLK B KBD DATA 1 KBD DATA G KBD 5V 4 KBD 5V D KBD GND 3 KBD GND E N C F N C Plea
17. VDC Return White 24 VDC return R Red N C Red N C Note Pins are not marked on the DC connector The pin numbers shown indicate the wire color used for each pin internally HAZARDOUS Interconnect NON HAZARDOUS Keyboard connector Keyboard connector CN Type ITT Cannon KPT02A10 6S Std PS2 female connector Mating ITT Cannon KPT06J10 6P i Std PS2 male connector A KBD CLK 5 KBD CLK B KBD DATA 1 KBD DATA G KBD 5V 4 KBD 5V D KBD GND 3 KBD GND E N C F N C Please refer to Figure A 4 1 3 and Figure A 4 2 1 33 A 4 1 Drawing Back connectors MODEL 2800 DC M3 U B F K B F c E D CDE Figure A 4 1 1 Figure A 4 1 2 Figure A 4 1 3 COM1 USB1 LAN connector Keyboard connector connector Figure A 4 1 4 DC power input connector 34 A 4 2 Drawing Cables for Non Hazardous location MODEL 2800 DC M3 Stand Alone Keyboard Mates to kb mouse connector on 2800 Figure A 4 2 1 DB 9 male COM 1 Mates to COM1 USB 1 connector on 2800 Figure A 4 2 2 Mates to LAN connector ee e on 2800 Figure A 4 2 3 Mates to DC input power connector on 2800 Figure A 4 2 4 35 A 5 2800 ACW M4 HAZARDOUS Interconnect NON HAZARDOUS USB SERIAL Connector USB connectors CN Type ITT Cannon KPT02A14 19S Conn Type Std USB A Socket
18. board connector Keyboard connector CN Type ITT Cannon KPT02A10 6S Std PS2 female connector Mating ITT Cannon KPT06J10 6P i Std PS2 male connector A KBD CLK 5 KBD CLK B KBD DATA 1 KBD DATA G KBD 5V 4 KBD 5V D KBD GND 3 KBD GND E N C F N C Please refer to Figure A 5 1 3 and Figure A 5 2 1 38 Figure A 5 1 1 USB1 USB2 connector A 5 1 Drawing Back connectors MODEL 2800 AC W M4 B F B F c E D CDE Figure A 5 1 2 Figure A 5 1 3 LAN connector Keyboard connector Figure A 5 1 4 Figure A 5 1 5 AC power input DC power input connector connector 39 A 5 2 Drawing Cables for Non Hazardous location Mates to keyboard connector on 2800 Mates to USB 1 USB 2 connector on 2800 Mates to LAN connector on 2800 Mates to AC input power connector on 2800 MODEL 2800 AC W M4 PS2 female keyboard Figure A 5 2 1 Figure A 5 2 2 MS RJ 45 plug Figure A 5 2 3 NEMA 5 15 Figure A 5 2 4 40 A 6 2800 AC M5 MODEL HAZARDOUS Interconnect NON HAZARDOUS USB SERIAL Connector USB connectors CN Type ITT Cannon KPT02A14 19S Conn Type Std USB A Socket Mating ITT Cannon KPT06J14 19P Mating Std USB A connector Pin Signal Pin Signal A N C B USB1 5V 1 5 V C USB1 D 2 D D USB1 D 3 D E USB1 GND 4 GND RS 232 connector F N C CN Type Standard DB 9
19. d Figure A 3 2 3 HAZARDOUS Interconnect NON HAZARDOUS Keyboard connector Keyboard connector CN Type ITT Cannon KPT02A10 6S CN Type _ Std PS2 female connector Mating ITT Cannon KPT06J10 6P Mating Std PS2 male connector A KBD GLK 5 keyboard KBD CLK B KBD DATA 1 keyboard KBD DATA G KBD 5V 4 kb m KBD 5V D KBD GND 3 kb m KBD GND E MOUSE CLK 5 mouse MOUSE CLK F MOUSE DATA 1 mouse MOUSE DATA Please refer to Figure A 1 and Figure A 6 Black Box Connector on 2800 AC M2 Please refer to Figure A 3 1 2 Connector type ITT Cannon MS3102E14S 5P Mating connector ITT Cannon MS3106F145 5S Pin out Pin Signal A RCV B RCV c XTM D XMT E BB terminal strip 28 A 3 1 Drawing Back connectors MODEL 2800 AC M2 U B F 8 c E D Figure A 3 1 1 Figure A 3 1 2 Figure A 3 1 3 LAN USB1 Black box connector Keyboard mouse connector connector Figure A 3 1 4 AC power input connector 29 A 3 2 Drawing Cables for Non Hazardous location MODEL 2800 AC M2 PS2 female keyboard Mates to kb mouse connector on 2800 PS2 female mouse Figure A 3 2 1 Mates to LAN USB 1 connector on 2800 Figure A3 2 1 2 Mates to AC input NEMA 5 15 power connector on 2800 Figure A 3 2 3 30 A4 2800 DC M3 HAZARDOUS Interconnect NON HAZARDOUS
20. devices in the non hazardous area that provide the LAN and RS232 interfaces to the 2800 Disconnect the POWER INPUT connector from the 2800 Disconnect the LAN connector Disconnect the Serial connector Disconnect the keyboard connector Remove the 2800 from its mounting stand and move it out of the hazardous location DN O NOO R WARNING Not following the above sequence may induce an explosion hazard 14 SECTION 6 MAINTENANCE z SERVICING PE eee 6 1 MAINTENANCE The only regular maintenance procedures required on the 2800 are a Clean the touch screen with water or any commercial window cleaner using a clean soft lint free cloth Care must be taken not to scratch the touch screen during the cleaning process Do not use any abrasive substance or any organic solvents to clean the touch screen b Clean the photo resistor lens in the same manner as described in a above c Clean the top heat sink to remove all dirt and foreign objects that may be stuck between the fins of the heat sink WARNING Do NOT pressure wash the 2800 6 2 SERVICING CAUTION Risk of explosion if battery is replaced by an incorrect type Dispose off used batteries in the prescribed manner WARNING Substitution of components is strictly prohibited WARNING The Model 2800 does not contain any user serviceable or user replaceable components The 2800 must not be opened by the user in an attempt to repair or service the unit Doing so may sev
21. e not energized whenever the power source is either connected or disconnected from the unit WARNING The unit must never be opened or left open in a hazardous location The rear panel and the top heat sink must be securely fastened before the unit is introduced into a hazardous location WARNING Do not install or operate this unit in an area where the temperature is outside the limits indicated on the information label on the rear panel of the unit WARNING All connections made to the unit must strictly adhere to the rules set forth in Section 3 2 of this manual WARNING There are no user serviceable components inside this unit The unit must not be opened to repair or replace any components If components are repaired or replaced by the user the unit may no longer be suitable for use in hazardous locations and may become an explosion hazard WARNING The Model 2800 is suitable for use in Class I Division 2 Groups A D hazardous locations and non hazardous locations only CAUTION Do not cover or obstruct the slots and fins on the top heat sink in a manner that would restrict air flow between the slots or across the fins CAUTION Do not install the unit in an unstable manner that could cause it to tip over CAUTION Follow all instructions and warnings marked on the unit and also those included in this manual Approvals The Model 2800 conforms to the following standards UL60950 CSA 60950 CAN CSA C22 2 No 60950 00 U
22. erely impair the hazardous location classification of the unit All repairs and servicing of the unit can only be performed at the Laversab facility 15 SECTION 7 WIRELESS OPTION Wireless option applies to the following 2800 models 2800 ACW Std 2800 DCW Std 2800 ACW M4 2800 ACW M7 These models are equipped with a set of two 900 Mhz radios one inside the unit master radio and a stand alone radio remote radio Master Radio inside 2800 Remote Radio Note For radio configuration please refer to Wireless Radio Setup Manual 16 APPENDIX A EXTERNAL CONNECTIONS HAZARDOUS NON HAZARDOUS LOCATIONS C D _ gt EEE mm The external connectors pin outs and connection details shown below reference the Control Drawing shown in Figure A 1 Individual connector drawings are shown in Figures A2 through A6 A 1 MODEL 2800 STANDARD HAZARDOUS Interconnect NON HAZARDOUS USB SERIAL Connector USB connectors CN Type ITT Cannon KPT02A14 19S Conn Type Std USB A Socket Mating ITT Cannon KPT06J14 19P Mating Standard USB A connector Pin Signal Pin Signal A N C B USB1 5V 1 5 V C USB1 D 2 D D USB1 D 3 D E USB1 GND 4 GND RS 232 connector F N C CN Type Standard DB 9 male Mating Standard DB 9 female Pin Signal G RX__ COM1 2 Fe H TX COM1 3 TX J GND COM1 5 GND K U
23. male Mating Standard DB 9 female Pin Signal G RX__ COM1 2 ad H TX COM1 3 TX J GND COM1 5 GND K USB2 D L USB2 D M USB2 GND N N C P N C R USB2 5V S N C T N C U N C V N C Please refer to Figure A 6 1 1 and Figure A 6 2 2 41 HAZARDOUS lL 4 NON HAZARDOUS LAN Connector 2800 LAN connector CN Type ITT Cannon KPT02A12 8S CN Type Standard RJ 45 plug Mating ITT Cannon KPT06J12 8P Mating Standard RJ 45 socket Pin Signal Pin Signal A TD 1 TD B TD 2 TD C RD 6 RD D RD 3 RD E N C 4 N C F N C 5 N C G N C 7 N C H N C 8 N C Please refer to Figure A 6 1 2 and Figure A 6 2 3 HAZARDOUS Interconnect NON HAZARDOUS AC Power Input Connector AC connector CN Type B Harrison 1R3G06A20A120 CN Type Std NEMA L6 15 Plug Mating B Harrison 103000A01F060 Mating Std NEMA L6 15 socket Pin Signal Pin Signal G Green Earth Ground G Earth Ground W White Neutral Y Neutral B Black Line X Line Please refer to Figure A 6 1 4 and Figure A 6 2 4 42 HAZARDOUS Interconnect NON HAZARDOUS Keyboard connector Keyboard connector ITT Cannon KPTO2A10 6S CN Type _ Std PS2 female connector ITT Cannon KPT06J10 6P Mating Std PS2 male connector Pin Signal Pin Signal A KBD CLK 5 KBD CLK B KBD
24. n any form by any means in part or in whole without the prior written permission of Laversab Inc DISCLAIMER No representations or warranties are made with respect to the contents of this user s manual Further Laversab Inc reserves the right to revise this manual and to make changes from time to time in the content hereof without obligation to notify any person of such revision WARNING THE 2800 USES LINE VOLTAGES FOR ITS OPERATION WHICH ARE POTENTIALLY DANGEROUS IMPROPER OPERATION OF THIS EQUIPMENT MAY RESULT IN PERSONAL INJURY OR LOSS OF LIFE HENCE THE EQUIPMENT DESCRIBED IN THIS MANUAL SHOULD BE OPERATED ONLY BY PERSONNEL TRAINED IN PROCEDURES THAT WILL ASSURE SAFETY TO THEMSELVES TO OTHERS AND TO THE EQUIPMENT BEFORE PERFORMING ANY MAINTENANCE TURN THE POWER OFF AND DISCONNECT THE POWER CORD FROM THE POWER SOURCE TABLE OF CONTENTS WATTS a a I Copynehtnoticesdiselainier aa ii Revision SODY Io dond iii Warnings rra iv Section 1 ThtrOductiOn EETA E ETE E A EE 1 Section 2 Safely ai 4 Section 3 HSA Ofl iii kW Z O Gad ee eles 6 Jal Loading Software sua cta 6 3 2 Mounting e 2000 is 6 3 3 Connections to the 2800 ccooonccccnnnoccccnononnnnnnononcnnnononnnnnnnnnnnncnononnnnnnnnnncnnnnnncninnnns 8 3 3 1 Non hazardous locations ecccesesccccessccceessnccecessscccecessscceceesssceseesscceseees 8 3 3 2 Hazardous locations o ccceecceesssccccssssscceseccceesenccecessncccecesssaceccessaceseessaceeena
25. nes 8 Section 4 Typical Use v aan 12 Section 5 Removal AE E E EREE DA EA E E A 14 Section6 Maintenance amp Servicing saab td 15 Section 7 2800 Wireless Option andunuduaddaandndadndndedsdudndad adsense 16 Appendix A Ext Connections in Hazardous Non Hazardous Locations 17 A 1 2800 Standard model aaa ii anek 17 A 1 1 Drawings Back Connectors wi AE Ala 20 A 1 2 Drawings Cables for Non Hazardous Locations 1 1111111111 21 A 2 2800 DC MlEm del asy ad eed dis 22 A 2 1 Drawings Back Connectors sidad 25 A 2 2 Drawings Cables for Non Hazardous Locations 1 1111111111 26 A 3 2800 AC M2 model eoccccnnnoccncnononncnnnononcnnnnnnnnnnnnonnnnnnnnnnnnncnnannnnncnnnnnnnnnannnnccnns 27 A 3 1 Drawings Back Connectors und 29 A 3 2 Drawings Cables for Non Hazardous Locations 1111111111 30 AA 2800 DE M3 model canada 31 A 4 1 Drawings Back Connectors aid 34 A 4 2 Drawings Cables for Non Hazardous Locations 1111111111 35 A 5 2800 ACW MA4 model enoooccccnnncccccnoncconononcnnnnononononononcnnnnnnnnnnnnnnnnnnncnnnnnccnnnnnos 36 A 5 1 Drawings Back Connectors ad add 39 A 5 2 Drawings Cables for Non Hazardous Locations 11111111111111 40 A 6 28000 A C M5 model maraa aaa aaa aaa aaa a 41 A 6 1 Drawings Back Connectors italia 44 A 6 2 Drawings Cables for Non Hazardous Locations 1111111111111 45 A 7 2800 AC M6 model cocccnonoccncnononcncnononcnnnn
26. nnononcnonnnnnnonononnncnnnnnnncnnnnnnnncnanencninnnos 46 A 7 1 Drawings Back Connectors pt 49 A 7 2 Drawings Cables for Non Hazardous Locations 111111111111 50 A 8 2800 ACW M7 model onoooccccnnnoccccnoonccnnnonononononnnnnnonononnccnnnnncncnnnncncnnnnncnccinnnns 51 A 8 1 Drawings Back Connectors o 54 A 8 2 Drawings Cables for Non Hazardous Locations 1111111111111 55 Appendix B Repair and Return Policies ue AAA 56 vi SECTION 1 INTRODUCTION ooo COUO The model 2800 Industrial computer is a PC compatible computer that is specifically designed for use in hazardous locations that are classified as Class 1 Division 2 Typical applications include rig floor monitoring and use in chemical plants The rugged yet compact design of the 2800 makes it easy to install and remove off rig floors and makes it suitable for use under all weather conditions The 2800 is shown ifnFigure 1 1 The 2800 model is available in the following options 2800 AC Rev D Standard a 2800 AC M2 Rev B b 2800 AC M5 Rev A c 2800 AC M6 Rev B 2800 ACW Rev B Standard Wireless a 2800 ACW M4 Rev B b 2800 ACW M7 Rev B 2800 DC Rev D Standard a 2800 DC M1 Rev B b 2800 DC M3 Rev B 2800 DCW Rev B Standard Wireless Standard Features Pentium M 1 8 GHz CPU or Atom 1 6 GHz CPU 15 0 TFT Color Ultra Hibrite sunlight readable display with 1024 x 768 resolution Auto dimming of display brightness based on ambient light High
27. rear panel of the 2800 is provided in Appendix A The mating connector is also listed in Appendix A WARNING The LAN cable may only be terminated into a 10 100 M bit Ethernet LAN device that adheres to the IEEE 802 3 standard The Control Drawing for this connection is shown in Figure A 1 A shielded CAT 5 cable may be used to provide this connection to the 2800 Although no special cable protection is required in a hazardous location it is recommended that the LAN cable be run in the same rigid conduit used for the power cable WARNING Make sure that the POWER and circuit breaker on the rear panel of the 2800 are in the OFF position before connecting or disconnecting the LAN connector Do not connect or disconnect the LAN connector when the circuits are energized 4 Keyboard cable The pin out for the keyboard connector on the rear panel of the 2800 is provided in Appendix A The mating connector is also listed in Appendix A For details on the keyboard cable please refer to the Control Drawing shown on Figure A 1 WARNING The keyboard cable may be connected only to an intrinsically safe keyboard per the Control Drawing shown in Figure A 1 The recommended keyboard is the model KBM IS WARNING The keyboard cable must be terminated in a locking connector The intrinsically safe keyboard must be able to mate to this locking connector WARNING Do not connect or disconnect the keyboard when the circuits are energized Make sure tha
28. resolution scratch resistant touch screen Fully sealed redundant mouse Up to 1 GB System RAM 2 5 form factor HDD minimum of 80 GB 2 5 form factor SSD minimum 8 GB optional 110 220 VAC or 24 VDC nominal operating voltage Two USB ports barrier protected One Serial Port barrier protected One Ethernet port barrier protected One external Keyboard port barrier protected Two 900 MHZ Wireless Radio with antenna Wireless models only Internal heaters operating on 110 220 VAC allow operation between 40 C and 50 C Sealed enclosure allows operation outdoors Total weight of 25 Ibs makes it easily portable Dimensions of 16 5 wide 14 5 high and 4 5 deep provide a small form factor UL 1604 CSA C22 2 No 213 certified for use in Class 1 Division 2 locations Groups A B C and D Temp code T6 00 NOT CONNECT OR DISCONNECT ANY CONNECTOR WHEN ENERGEED POWER PUT TRANS AG PONER TOWNS OHE AN on OFF PONER FOR HEATERS ONLY COMPLIES WITH UL60950 84 0722 No 606500 UL1004 Listing 8 E112472 CSAC222 No 2341997 c us Manufacturer Laversab Inc Model 2800 Serial No 75042 Electrical rating 1 Forall circuits except heaters 24 Volts DC 4 amps 2 For heaters ony 110 Volts AC 60 Hz 2 amps 220 Volts AC 50 Hz 1 amp Hazardous Location Designation Class 1 Division 2 Groups A B C D Temperature Rating T6 Enclosure designation NEMA 4 Operating Temperature 40 C to 50 C or 40 F to 122
29. se refer to Figure A 8 1 3 and Figure A 8 2 1 53 A 8 1 Drawing Back connectors MODEL 2800 AC W M7 U B K B F E E D CDE Figure A 8 1 1 Figure A 8 1 2 Figure A 8 1 3 RS232 USB1 RS422 XDUCER LAN connector Keyboard connector connector G B w Figure A 8 1 4 AC power input connector 54 A 8 2 Drawing Cables for Non Hazardous location MODEL 2800 AC W M 7 Mates to keyboard PS2 female connector on 2800 keyboard Figure A 8 2 1 Mates to COM 1 USB 1 RS 422 XDUCER connector on 2800 RS 422 KPTO1F 12 10S XDUCER KPTO1A 10 6P Figure A 8 2 2 Mates to LAN connector on 2800 RJ 45 plug Figure A 8 2 3 Mates to AC input NEMA 5 15 power connector on 2800 Figure A 8 2 4 55 APPENDIX B REPAIR AND RETURN POLICIES If it is determined that the product is defective please call Laversab customer service department 281 325 8300 or e mail lt oservice laversab com gt for further assistance Before shipping any equipment to Laversab for repair please call the customer service department at 281 325 8300 or e mail to lt oservice laversab com gt Please include a description of the problem that has been identified when returning defective equipment Ship equipment to LAVERSAB INC 505 Gillingham Lane Sugar Land Texas 77478 U S A 56
30. t the POWER circuit breaker on the rear panel of the 2800 is in the OFF position before connecting or disconnecting the keyboard 10 5 USB Serial cable WARNING The USB part of the cable may only be terminated into a connection that adheres to the USB 1 1 standard The Control Drawing for this connection is shown in Figure A 1 WARNING The Serial part of the cable may only be terminated into a connection that adheres to the EIA RS 232C standard The Control Drawing for this connection is shown in Figure A 1 WARNING Do not connect or disconnect the USB Serial connector when the circuits are energized Make sure that the POWER and circuit breaker on the rear panel of the 2800 are in the OFF position before connecting or disconnecting the USB Serial connector A shielded cable may be used to provide the USB Serial connection to the 2800 Although no special cable protection is required in a hazardous location it is recommended that this communication cable be run in the same rigid conduit used for the power cable 11 SECTION 4 TYPICAL USE After the 2800 has been installed per the instructions provided in Section 3 of this manual the unit may be turned ON for operation in the following sequence 1 Turn ON the external power source AC or DC 2 TurnONthe devices that provide the Ethernet and RS232 interfaces in the non hazardous location 3 Turn ON the POWER circuit breaker AC or DC on the 2800 If the ambient temperat
31. tor on 2800 Mates to COM 1 USB 1 USB 2 connector on 2800 Mates to LAN connector on 2800 Mates to DC input power connector on 2800 Mates to AC input power connector on 2800 PS2 female keyboard Figure A 1 2 1 Figure A 1 2 2 RJ 45 plug Figure A 1 2 3 NEMA 5 15 Figure A 1 2 5 26 A 3 MODEL 2800 AC M2 HAZARDOUS Interconnect NON HAZARDOUS USB SERIAL Connector USB connectors CN Type ITT Cannon KPTO2A14 19S Conn Type Std USB A Socket Mating ITT Cannon KPT06J14 19P Mating Standard USB A connector Pin Signal Pin Signal A N C B USB1 5V 1 e C USB1 D 2 D D USB1 D 3 D E USB1 GND 4 GND F N C G N C H N C J N C K N C L N C M N C LAN connector N N C CN Type Standard RJ 45 plug P N C Mating Standard RJ 45 socket R NC Pin Signal S LAN TD l TR T LAN TD 2 ID U LAN RD 6 RD v LAN RD 3 ND Please refer to Figure A 3 1 1 and Figure A 3 2 2 27 HAZARDOUS Interconnect NON HAZARDOUS AC Power Input Connector AC connector CN Type B Harrison 1R3GO06A20A120 CN Type Std NEMA L6 15 Plug Mating B Harrison 103000A01F060 Mating Std NEMA L6 15 socket Pin Signal Pin Signal G Green Earth Ground G Earth Ground W White Neutral N Neutral B Black Line X Line Please refer to Figure A 3 1 4 an
32. uld not restrict air flow between the fins of the top heat sink CAUTION The mounting bracket should not cover the photo resistor lens on the front of the 2800 GONPLESWIH UL60950 CSA CIZZ Na 696040 ULt604 Using Etar CSAC222 No 210 987 NAS us Manufacturer Laversab Inc Model 2800 Serial No 75042 Electrical rating 1 For all circuits except heaters 24 Volts DC 4 amps 2 For heaters only 110 Volts AC 60 Hz 2 amps 220 Volts AC 50 Hz 1 amp Hazardous Location Designation Class 1 Division 2 Groups A B C D Temperature Rating T6 Enclosure designation NEMA Operating Temperature 40 C to 50 C or 40 F to 122 F CAUTION The internal lithium battery on tho CPU board must be replaced with 22 volt ZOmm size Ithlum battery only CAUTION Keep cover tight while circuits or heaters are energized CAUTION Please refer to the User s Manual for Installation instructions and a list of approved equipment that may be connected to this unit Connecting equipment that Is not on the approved Ist may Impalr the Hazardous Location designation of this unt WARNING Substhution of components Is strictly prohibited WARNING WARNING WARNING 00 NOT CONNECT OR DO NOT CONECT OR c 20 NOT CONECT OR DISCOMECT AN CONNECTOR DISCONNECT ANY CONECTOR DISZ WNECT AMY CONNER WW ENERO UE ENERGUED Wh EMERGED AG POWER NPUT AC PONER VAS 20 ANP oc POWER FoR ML CIRCUS use USE OFF POWERFOR ov CEPT HEATERS Kereon con cove Figure 3
33. ure is below 5 C then the 2800 may not boot up immediately The internal heaters and fans will start operating and attempt to bring the temperature inside the 2800 above 5 C While this process is on going the heaters LED will turn on indicating that the heaters are operating The heaters may operate for up to 30 minutes before the internal temperature rises above 5 C at which point the computer section of the 2800 will boot up When the computer section of the 2800 is starting to boot up the backlight on the display will turn on and the display will be completely white for a period of about 2 to 5 seconds Thereafter the boot up screen will be displayed During normal use the application software will communicate through the LAN and or the Serial port and show the necessary information on the display The keyboard may be used as an input device by the user but typically the touch screen and or the mouse on the front panel are the only input devices used CAUTION Do not use a sharp object to touch the touch screen Scratching the touch screen surface in any way will cause the touch screen to mal function The mouse on the front panel is configured such that the circular button in the center is the cursor movement button and the two buttons on either side of it are the left and right click keys The circular button is pressure sensitive The harder it is pressed the faster is the cursor movement The mouse and the touch screen ma
34. y be used alternately This means that they are both active at all times and cursor movements and icon selections etc may be done by either one of them The right click function on the touch screen is available and can be configured through the driver application Cursor movement and icon selection is easier with the touch screen whereas dragging is easier with the mouse If the touch screen is inoperative the mouse will still provide the user with input capability Thereby the mouse provides redundancy for the touch screen 12 The photo resistor lens on the front of the unit must be kept un obstructed and clean during normal operation This will allow the auto dimming circuit to properly regulate the brightness of the display based on the ambient light conditions WARNING During normal operation the user must not alter any of the connections to the 2800 including the keyboard connection Before altering connecting or disconnecting any connection both circuit breakers on the 2800 must be turned OFF so that all internal circuits are de energized Failure to do so may create an explosion hazard 13 SECTION 5 REMOVAL While removing de installing the 2800 from normal operation follow the sequence shown below WARNING Do not disconnect ANY connectors while circuits are energized 1 Turn OFF the POWER circuit breaker on the 2800 Turn OFF the external power source located in the non hazardous area Turn OFF the