Home

SP EIFFEL400_UK

image

Contents

1. 1 Open the protective cap Fig 25 2 IInsert the key and turn it 90 Fig 26 Page 10 Note To move the operator in manual operation insert the key and rotate it 90 degrees clockwise to unlock the motor and turn off the power supply IMC La WO SC Fig 25 7 1 To restore normal operating conditions proceed as follows 1 Close the gate 2 Turn the release system 90 in the opposite direction of the arrow 3 Remove key and close protection cover 4 Power up the system and perform 1 movement in order to check the correct restoring of every function of the automated system 8 MAINTENANCE To ensure trouble free operation and a constant safety level an overall check of the system should be carried out every 6 months A form for recording operations has been included in the User s Guide booklet 9 REPAIRS For any repairs contact an authorized repair center 10 AVAILABLE ACCESSORIES Refer to catalogue for available accessories 11 SPECIAL APPLICATIONS There is no special application other than the described use Page 11
2. internal 6 Stopper Mandatory 5 3 Installation dimensions Determine the fitting position of the operator ATTENTION Check with care if the distance between the open leaf and any obstacles wall fence etc is higher than the operator Stroke 5 3 1 General rules to determine the installation dimensions If the pillar dimensions do not allow the installation a hole on the pillar should be created example Fig 8 The hole should be dimension in such a way to enable easy installation rotation and release device operation To help on the cut of the pillar decrease the size of the wall bracket 5 4 Preliminary checks 1 Fix the rear bracket in the position determined before If the pillar is in iron carefully weld the bracket directly to the pillar Fig 10 If the pillar in masonry use suitable accessories to fix the motor to the wall fig 09 using the provided screws During the fastening operations check if the bracket is perfectly horizontal using a level Fig 08 LL Fig 09 Fig 10 2 Assemble the rear brack fitting to the operator as shown in Fig 11 and Fig 12 Page 07 ATTENTION The operator can be moved by hand only if it is installed on the gate and in released position 3 Assemble the front bracket as shown in Fig 14 a hex
3. 9 Long screw 2 Rear fitting 10 Steel tube 3 Release device 11 Bronze nut 4 Electric wire 12 Frontal fitting 5 Aluminium body 13 Limit Switch protection 6 Arm 14 Front bracket 7 Limit Switch 15 Front cover 8 Worm screw 1 2 Dimensions mm Page 03 Fig 03 2 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS SP EIFFEL 400 Power supply V 230V 50Hz Power W 200W Current A 0 8A Thermal protection C 120 C Capacitor uF 12uF 400V Thrust N 1000N Travel mm 400mm Speed cm s 1 6cm sec Max Leaf dimension m 4 5m Usage frequency at 20 C 30 Protection class IP54 Working temperature gt 20 C lt 65 C 3 INSTALLATION TOOLS There are some operating tools before installation as follow iy SS SS D NS Page 04 4 PACKING LIST You must check the operator packing before installing the automated system Ne Descri o Quant Motor Rear bracket Front bracket Key Rear bracket fasteners Front bracket fasteners NIN IAAI IN NINININ 5 INSTALLATION 5 1 Pre installation checks ATTENTION To ensure a correct operation of the automated system make sure the following requirements are observed as for the gate structure existing or to be realized The leaf must be
4. components of the automated system 19 The installer shall supply all information concerning manual operation of the system in case of na emergency and shall hand over to the user the warnings handbook supplied with the product 20 Do not allow children or adult to stay near the product while it is operating 21 Keep remote controls or other pulse generators away from children to prevent the automated system from being activated involuntarily 22 Transit through the leaves is allowed only when the gate is fully open 23 The user must not attempt any kind of repair or direct action whatever and contact qualified personnel only Page 02 1 DESCRIPTION The SP EIFFEL 400 automated system for swing gates comprises an electromechanical operator which drives the gate leaves by means of a worm screw The operators are equipped with a limit switch to control the stroke of the motor The operator is irreversible and locks mechanically when the motor is not in use therefore a lock does not need to be fitted ATTENTION The SP EIFFEL 400 automated system was designed and manufactured to control access of vehicles Avoid any other use whatever The motors must be installed at a minimum height of 20cm from the ground surface and not interfere with the mobile parts Command pulses must be given from sites where you can see the gate Use transmitters only if you can see the gate 1 1 Structure Description Fig 01 1 Rear bracket
5. wired in the same terminal board where the motor wiring has been carried out After connected close all the cover with screws Page 09 5 6 Limit Switch The limit switch adjustment is carried out as follows 1 Loosen front cover screws of the front cap and remove the cover Fig 20 2 Move the cover of the limit switch Fig 21 Q Y Fig 20 4 3 Loosen the fastening screw of the limit switch 4 Move the limit switch to the desired position and lock the screw Fig 22 Fig 22 5 Perform a pair of test cycles to check the correct position of the limit switch If the adjustment of the limit needs to be carried out again repeat the operation starting from point 3 6 After adjusting the limit switch place back it s protection Fig 23 e Fig 24 7 Tighten the screws A Q a Z Fig 23 Fig 24 6 TESTING THE AUTOMATED SYSTEM Carefully check operating efficiency of the automated system and of all accessories connected to it paying special attention to the safety devices Hand the User s Guide to the final user to get him with the Maintenance sheet Explain correct operation and use of the automated system to the user Indicate the potentially dangerous areas of the automated system to user 7 MANUAL OPERATION If the automated system needs to be moved manually due to a power lack or to an operator malfunction proceed as follows
6. Automation wing Gate Opene Operating and installation instructions SP EIFFEL 400 CONTENTS 0 GENERAL SAFETY REGULATIONS oococccccconiconoinoniconncnononinnononicanacnonicon Page 02 o EE Page 03 2 TECHNICAL SPECIFICATIONS n se Page 04 INSTALLATION TOOLS das e Page 04 AJ GOMPONENTS usando Page 05 INSTALL TI N gt ias Page 05 6 TESTING THE AUTOMATED SYSTEM eessen Page 10 7 MANUAL OPERATION ccoo Page 10 8 MAINTENANCE sia Page 11 OBRERAS erario Page 11 ID AVAMLABLE ACCESSORIES nunca Page 11 HIVSPECIALAPPIICATION sica Page 11 Page 01 IMPORTANT NOTICE FOR THE INSTALLER GENERAL SAFETY REGULATIONS 1 ATTENTION To ensure the safety of people it s important that you read all the following instructions Incorrect installation or incorrect use of the product could cause serious harm to people 2 Carefully read the instructions before beginning to install the product 3 Do not leave packing materials plastic polystyrene etc within reach of children as such materials are potential sources of danger 4 Store these instructions for future reference 5 This product was designed and build strictly for the use indicated in this documentation Any other use not expressly indicated here could compromise the good condition operation of the product and or be a source of danger 6 We decline all liability caused by improper use or use other than that for which the automation swing gate opener was intended 7 Do not i
7. agonal seat is located in the lower part of the fitting to make the assembling operations easier Fig 13 4 Close the leaf and keeping the operator in a perfect horizontal position determine the fastening point Close the leaf and keeping the operator in a perfect horizontal position determine the fastening point of the front bracket Note if the gate structure does not allow a fix bracket fastening it is necessary to create a sturdy supporting base in the gate structure Page 08 5 Release the operator and manually check if the gate can completely open without hindrances and stop at the mechanical travel stop as well as if the leaf moves regularly without any friction 6 Carry out necessary corrective measures Note we recommend to grease all the fastening pins of the fittings 5 5 Wiring the operator A terminal board is fitted in the lower part of the operator for the connection of the motor or the limit switch Fig 16 5 5 1 Motor wiring operations 1 1 Move the terminal cover and bottom cover fit the supplied cable gland Fig 15 e 16 2 Connect the motor and the earthing with reference to Fig 17 Pos Cor 1 Azul Comum 2 Castanho Fase 3 Preto Fase 4 Amarelo Verde Fio terra Fig 17 3 The limit switch is
8. fixed firmly on the hinges to the pillars and must not be flexible during the movement Before the installation of SP EIFFEL 400 verify all dimensions etc The mechanical parts must conform to the provision of standards EN12604 and En12605 Leaf length in compliance with the operator specification The 2 leaves must have a robust and rigid structure suitable for automation The leaves should have a regular and uniform movement without any friction and dragging during the entire opening Presence of an efficient earthing for electrical connection of the operator The condition of the gate structure directly affects the reliability and safety of the automated system Page 05 5 2 STANDARD INSTALLATION LAYOUT 1 Operators 2 Photocells 3 Logic board 4 Key operated push button 5 Receiver 6 Flashing lamp NOTA Use suitable tubes and or hoses to lay electric cables To avoid any kind of interference always separate low voltage accessories and control cables from 230V power supply cable using separate tubes Ma 1 Motors 2 Antenna 3 Flashing lamp 4 Photocells external 5 Photocells
9. nstall the equipment in an explosive atmosphere the presence of inflammable gas or fumes is a serious danger to safety 8 The mechanical parts must conform with standards EN12604 and EN12605 9 We are not responsible for failure to observe Good Technique in the construction of the closing elements to be motorized or for any deformation that may occur during use 10 The installation must conform to standards EN12453 and EN12445 The safety level of the automated system must be C D 11 Before attempting any job on the system cut out electrical power 12 The main power supply of the automated system must be fitted with an all pole switch with contact opening distance of 3mm or greater Use a 6A thermal breaker with all pole circuit break is recommended 13 Make sure that the earthing system is perfectly constructed and connect metal parts of the means of the closure to it 14 The safety device EN12978 standard protects from any danger are as against mechanical movement Risks such as crushing dragging and shearing 15 Use of least one indicator light is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices mentioned at point 14 16 We decline all liability as concerns safety and efficient operation of the automated system if system components not produced by us are used 17 For maintenance strictly use original parts by us 18 Do not in any way modify the