Home
TSR Manual, English
Contents
1. Serial serial number of the TempStick Radio followed by the number of the radio itself this last number is listed in the graph Expiry the calibration expiring date of the unit Starting a mission Click on Start to open the programming window of the TempStick Radio In the Start Date Time box select the date and time at which you would like the mission to start If it is the current date and time the mission will start immediately otherwise you can set the mission to start in the future In the Transmission Step box you must define the acquisition rate expressed in days hours minutes and seconds You may leave unnecessary fields blank you do not have to enter 0 You may also type a Description for the unit so to recognize it instead of using its serial number and some additional Notes at the end to help you identify the mission in the future Click on OK to start the mission Start Date Time Click on Unlink before removing the unit from the interface TecnoSoft s r l TSR 13 17 Receiving the transmitted data To display real time the data transmitted from the TempSticks Radio you have click on the Radio button it is enabled only if a USB Radio Receiver is connected once the connection is established a window displaying a graph and table will appear To maximize it click on the magnifying glass in the bottom right corner of the window Maximize Window Date Time 17 01 2008 10 77 41 54 Te
2. Each sensor transmitter is identified by means of two unique serial numbers one for the sensor itself and one for the radio and if requested may be supplied with a calibration certificate in order to guarantee the validity of the acquired readings Available devices Following the list of the devices currently supported by the SPD software with the needed accessories all with their product code Interface Data logger TempStick Radio ts01tsrxxyy 150115 200 Radio Configuration Interface ts04rci USB Radio Receiver ts04rr Temperature Intelligent Sensor ts11istxxyy ts11ist200xxyy 151 1151 80 Radio Node ts1 1rn 6 17 TSR Tecnosoft s r l System Requirements Hardware Description mum Recommended Microprocessor Celeron 300 Pentium III 400 Memory 1 GB 4 GB Video 800x600 256 colours 1024x768 16 Mil colours 1 USB free port for the Radio Configuration Interface 1 USB free port for the USB Radio Interface Software Description Supported Operating system Windows XP Vista 7 32 bit and 64 bit TecnoSoft s r l TSR 7 17 Installation To install TSR simply insert the installation CD into your CD ROM click on Start Run and type D setup exe N B Your CD ROM device could have a different name to Select the installation menu language and click on Install then select SPD and click Install again
3. Software version 1 1 2 0 TSR User s Manual Version date 07 03 2011 Management Software for TempStick Radio and Intelligent Sensors Radio Node Temperature wireless sensors 2 17 TSR TecnoSoft s r l Tecnosoft s r l Via Galvani 4 20068 Peschiera Borromeo Milano phone 39 02 26922888 fax 39 02 26922875 e mail info tecnosoft eu web www tecnosoft eu TecnoSoft s r l TSR 3 17 Index HCENSE AGREEMENT i e ida a ea Ee aeos ee Do Eon peto o eue Po DoD ata Doro dn d ED aa tata delhi eon 4 INTRODUCTION elle iii 5 AAV AMLKBEE DEVICES zouten ee tenen neo eeen nui benne eet Nee ne 5 SYSTEM REQUIREMENTS ERECTUS 6 HARDWARE ka se lo ne a tr ae ala cit a a i 6 CT PED C 6 INSTALLATION saba ilaele il ill 7 INSTRUMENTS AND ACCESSORIES ccccesecescsesccccscsccsssssccsecscecscccscccecscecscsosscsccsssssecsecsecees 8 CONNECTING THE DISKINTERFACE ss sirene 8 DEVICES CONNEGION lilla 8 CONNECTING THE USB RADIO RECENVER ina n 8 BASIC OPERATIONS a suna a Ac tavi ro a dar ct aa aie 9 LAUNCHING THE PROGRAMS au cesses een duca nt tut ala Aa d a 9 THE MAIN WINDOW ice E PEE E ee ee ru dat latu dia A E 9 INFORMATION AND ONONE een 9 EXIT THE PROGRAM pulcini ail 9 EONHSURATION Gila 10 TEMPERATURE MODE dq aio 10 CONNECTION aa ia 10 LANGUAGE Se N m 10 dde i M PEE TERT Tm 6 T 10 BM d eon Re
4. from this menu you can also open the PDF manual or the USB driver installation instructions Follow the instructions to complete the installation You may be required to install Microsoft NET before installing the TSR accept and proceed We suggest to install TSR for all users Everyone At the end click on Finish 8 17 TSR TecnoSoft s r l Instruments and accessories All loggers currently managed by the TSR software are connected to the PC by means of a single interface the Radio Configuration Interface The first thing to do is connect the interface to a free USB port and install the drivers Connecting the DiskInterface In the kit there is also a USB cable connect the biggest flat end in the free USB port of your PC while the other smaller end in the USB connector on the device As soon as the device is connected to the PC Windows will detect its presence and will begin the driver installation procedure According to your operating system proceed as follows USB driver installation under Windows XP In the Add New Hardware window select No not now last option and click Next Then select always the last option which requires manual installation of the driver for expert users and click Next Set in the path field the following path make sure the CD is in drive D Drivers XP_2000 32 bit your driver might not be called D and click Next If during installation Windows would give you a warning about the origin
5. ER 10 ALARM PROFILES alia 11 PRINTING OPTIONS er ee an IAD el ERE 11 AUTO SAVE En 11 START A NEW MISSION Sri ae Asse 12 INFORMATION ON THE UNI araldica 12 STARTING A MISSION cs ETT raci Baa a pi ese ai dota aflii a data 12 RECEIVING THE TRANSMITTED DATA cscscscscscsscscscsscsscscscscsscscscsccssscscscscsscecsssscescsscsscess 13 STATISTICS sabina lai iis 13 EXPORT DATA RTT DTE 13 ALARMS SEMIN G slanciata 14 MNS SION REPORT PRINTING oii la ic atu aditional luca uta st talc a dia lot a art la tat 14 SAVE THE MISSION sorted a sai Va d m 14 STOPPING A MISSION u cacat taci iano ed 15 DATA ARCHIVE ERREUR 16 OPEN MISSION FROM THE ARCHIVE illeciti 16 REMOVE A MISSION FROM THE ARCHIVE chase 16 RENAME A MISSION IN THE ARCHIVE cois mea sa sie b taia dida d iata Fax lase o br a Oaie dilata iata ada VE VE 16 IMPORT A MISSION FROM THE RADIO PRINTER cccccccccccccccccccccccccscccccccccccccccccccccccccccsccceccccccceccscccecesecsesccccceces 16 4 17 TSR TecnoSoft s r l License agreement Read this license agreement thoroughly before using the Software Using and copying this Software is subject to the acceptance of this agreement If you choose to refuse the following conditions please return this Software to the point of purchase for a complete refund This agreement involves Tecnosoft srl Redecesio di S
6. given by the Software are correct and appropriate In no case the Software should be used if such use can be threatening to the health or life of human beings This clause is applied even if the User does not accept the Software Updates If the Software is an update of a previous version the license is transferred from the old version to the update Only the update can be used unless the update is destroyed Separation of components The Software is licensed as a single product Components cannot be separated Limitations The User cannot convert decode decompile or disassemble the Software except for what is explicitly requested by applicable laws TecnoSoft s r l TSR 5 17 Introduction TSR is a software program that is used to configure and acquire data off TempStick Radio temperature sensors and transmitters Through a USB Radio Receiver it receives data from wireless sensors the TempStick Radio and shows temperature values in table and graph real time All data can be saved and printed in reports The software allows also the setting of thresholds for alarms The sensors are supplied with a replaceable battery with high autonomy based on the rate of transmission approximately with a transmission each 5 minutes the battery can last up to 7 years The data may be exported in Excel SLK file format TSR is also used to program the rate of transmission for the sensors provided that you have the appropriate interface to do this
7. go into alarm after you checked this the alarm will start again for this second unit To disable the sound alarm check the Disable Sound box Mission report printing It is possible to print a report of the mission currently displayed click on the Print report button the left most button in the right corner of the window It will open a dialogue window where you can type in some notes regarding the current mission Click on Report again to continue test From the dialogue box that appears select the printer and click on Print The Print Preview window will appear where the report is shown all the information regarding the mission along with the graph are there Click on Print to print or close the window to cancel Save the mission To save the mission click on Close A window will open where you type in the name for the mission or keep the default name identified by the date of the mission itself Click on the disk to proceed or on the X to exit without saving The data of each mission are automatically saved every 5 seconds in a file called LAST in the archive This is done so that if a blackout occurs you don t loose all the data Remember to rename the LAST record in the archive otherwise it will be overwritten by the new mission you will start TecnoSoft s r l TSR 15 17 Stopping a mission To stop a transmission in progress connect the interface and the TempStick Radio and click on Conne
8. is connected to the interface or when the USB Radio Receiver is connected Information and Online Help e Click on the question mark button in the Main Window The Info window will open displaying the software version and the program licence agreement Click on the question mark in this window to open the Online Help and on the X to close it Exit the program x To exit the program just click on the Close the program button i e the X on the top right of the Main Window 10 17 TSR TecnoSoft s r l Setup Configuration Click on the Setup button to open the window where you may set the program parameters To confirm changes click Accept Data and to cancel them click on Close bottom right corner e Temperature Mode Connection Language Export Path DataP ath Pragrammi T ecnaS aff T SH Alarm Profiles x z L od Printing Options The window is divided into several sections Temperature Mode Select the desired units to be displayed for temperature degrees Celsius or Fahrenheit Connection Select whether you use a USB interface or a serial one select from the list of available serial ports the port that corresponds to the one where the reader interface has been connected to connect the TempStick Radio not the USB Radio Heceiver which doesn t need any configuration at all Language You may choose the preferred language used throughout the program to effect changes close and star
9. of the unsigned drivers click Continue and after the procedure click Finish If you change the connection port of the interface you might be required to reinstall the drivers Note the Radio Configuration Interface drivers is available on the Tecnosoft website and are also found in the installation folder of the program if you lose the installation CD USB driver installation under Windows Vista 7 Windows will install the driver without success When you will get the option ask to specify a path to look for the drivers Set in the path field the following path make sure the CD is in drive D Drivers Vista_7 32 and 64 bit your driver might not be called D and click Next If during installation Windows would give you a warning about the origin of the unsigned drivers click Continue and after the procedure click Finish If you change the connection port of the interface you might be required to reinstall the drivers Note the Radio Configuration Interface drivers is available on the Tecnosoft website and are also found in the installation folder of the program if you lose the installation CD Unsuccessful installation If for various reasons the installation fails go to Control Panel System Device Manager or Hardware Device Manager for Windows XP select USB Ports and click the right button on RCI and select Update Driver Then follow the instructions above Devices connection The devices must be connecte
10. ars DI Ut g DI DI N Teona 5 an 85 01 Tecnagoll DI 100 Tecra I DI 01 54 Tecno t DI 01 t Toral 01 a Tchau DI 85 vrede 10 36 00 THES Teil TPO 200 10125 57 BE 17 02 2008 1036583 Term TRS 10 35 49 10 29 00 103000 105100 10 32 00 10 33 00 10 34 00 10 35 00 103600 10 37 00 PPTTPPPTPID IAS rii rr ri r The right part of the window displays all the data from all the units indicating the date and time the name of the unit the Description you set when starting the mission or the serial number of it as well as the temperature values You can scroll through the data using the right vertical bar On the left there is the graph which is blank at the beginning and under it there are four drop down list and a list under each one of them From the drop down list you can select one of the unit received and its graph will be displayed The borders and the drop down list will change colour and the lines in the graph will have the same colour of them Statistics On the right under the list of data there is a table that shows all the units received so far If you select one of them you will see its statistics on the bottom right e MIN the minimum temperature transmitted e AVG the average temperature the maximum temperatu
11. ct When connection is established click on the Stop sign in the right part of the window to stop the mission The unit will immediately stop transmitting 16 17 TSR TecnoSoft s r l Data Archive When a transmission session is saved TSR stores the data from that mission in the archive Please remember to setup the destination folder for the data files in the configuration window before saving data Click on Archive to display a list of missions that have been saved 2008 05 07 03 16 00 02 02 2009 15 34 49 AMVOI 09B20P46 24 02 2009 12 44 56 INFO 27 03 2008 17 56 22 Last 12 10 2007 17 04 28 PIPPO 02 02 2009 15 34 50 i Radio Printer 08062016 PRN 02 02 2009 15 34 Radio Printer 09013014 PRN 02 02 2009 15 34 Radio Printer 04013015 PRN 02 02 2009 15 34 Radio Printer 09020416 PRM 17 02 2009 16 51 This window will display a list of missions that may be ordered in chronological order based upon the mission start date and time by selecting the Date option in the Sorted By box or according to the their names by selecting the Mission option To close the window click on Close Open a mission from the Archive To open a mission double click on the entry in the list or select it and click on the Accept Data button on the bottom right Remove a mission from the Archive To delete a saved mission select it and click on Delete stored data Rename a mission in the Archive You might want to re
12. d to the free end of the cable connected to the Radio Configuration Interface in the connection named Connecting the USB Radio Receiver An essential part of the data logging system is the USB Radio Receiver that receives all the data from the different TempStick Radio and send them to the software Just insert the USB B type connection square end to the USB Radio Receiver and the USB A type connection flat end to your PC No driver installation nor configuration is needed TecnoSoft s r l TSR 9 17 Basic Operations Launching the Program Once the installation is complete double click on the TSR icon on the desktop to start the program alternatively navigate to Start Program Files or All the Programs if you re using Windows XP Tecnosoft TSR TSR For the use of the icon TSR AutoSave see p 11 The Main Window The left part of Main Window holds the function buttons whereas the central part of the window shows the details of the connected TempStick Radio when connection is established on the right corner the question mark opens the nfo window and the X closes the Main Window itself If you need to move the window within your desktop click on the dark green border at the top of the window with the left mouse button and keeping it pressed move the window to the desired position Initially only the Connect Archive and Setup buttons are be available the others will be enabled once a sensor
13. egrate Milano Italy henceforth called Tecnosoft and the User be it a physical or juridical person for the following software products henceforth called Software TSR and any software product accompanying it Tecnosoft grants the user a non exclusive right to use a copy of the software on a single computer provided that the user accepts the following conditions i n User license The Software is property of Tecnosoft and cannot be copied nor sold without the prior written authorization of Tecnosoft The Software is protected by Italian and European Laws and by International Treaties concerning intellectual properties Additional licenses The purchase of additional licenses conveys the right to use the Software on a corresponding number of computers at the same time Exclusion of liabilities Except for what stated by applicable laws in no case can Tecnosoft be considered liable for damages or losses direct or indirect including but not limited to loss or missing income suspension of activities loss of information or any other monetary or economical damage deriving from proper or improper use of the Software even if Tecnosoft has been advised of the possibility of such damages In any case the responsibility of Tecnosoft for such damages will be limited to the price paid for the Software This clause is applied even if the User does not accept the Software Use of Software results It is User s responsibility to check that results
14. like for fridges Set here every how many days or hours the software must save the data and restart the name of the file will be the standard one It is suggested to set a time no higher than 5 days After you have set this option close the program and restart it using the TSR AutoSave desktop icon The software will save the data at the set time and will close itself and start again If you want to close it permanently close the DOS window first 12 17 TSR TecnoSoft s r l Start a New Mission To start a new mission and program the unit ensure the interface is connected to the PC and that the unit is correctly connected to the interface Click on the Connect button in the Main Window after a while the connection is established and TSR will display some basic information about the data logger Moreover the Start button that were previously disabled are now enabled Information on the unit The central part of the window holds some information on the connected unit On the right the current temperature value read by the logger is shown On the left there are the following indications Started date and time at which the current mission was started Step transmission rate of the current mission Status device status Recording means the unit is acquiring data Stopped indicates the mission has ended Stand by implies that a mission is programmed and will start once the programmed start delay time has elapsed
15. name a mission especially the Last mission if this is a result of an accidentally interrupted transmission Select it and click on Rename the disk icon to change its name Import a mission from the Radio Printer After having connected the USB pen drive to the PC enter the Archive of the TSR and press the button Import from Radio Printer Select the folder where the files you want to import are and press Open Then choose a name for the file and confirm and your mission will be listed in the Archive TecnoSoft s r l TSR 17 17 Tecnosoft s r l Via Galvani 4 20068 Peschiera Borromeo Milano telephone 39 02 26922888 fax 39 02 26922875 e mail info tecnosoft eu web www tecnosoft eu Certified UNI EN ISO 9001 2008 fo Software development
16. re transmitted You may select more than one unit from the list pressing the CTRL button keep it pressed and select the units you want to see the statistics of To see the statistics of all data received look in the Global box below the list of transmitters Export data To export the data for this mission click on the Export Data button the disk located at the bottom right of the window if you have not set the destination folder for the exported files Configuration chapter p 10 the data 14 17 TSR TecnoSoft s r l will be exported in the main folder of the program The export file has a SLK extension and may be imported in Excel Alarms setting In the same way you select the units to see their statistics you can select them and assign an alarm profile to each of them Select one or more unit and then assign it or them a profile from the drop down list Alarm Profile When an alarm occurs according to the parameters set in the profiles the unit that is in alarm will turn red and a sign will appear if the temperature is above the maximum threshold and blue with a sign if the temperature is below the minimum threshold if you see only the signs it means that there had been alarm in the past for that sensor Also there will be a sound alarm When all the alarmed units will return between the thresholds the alarms will cease You can turn off the sound alarm by checking the Stop Sound Alarm box note that if another unit will
17. t the program again Export Path The folder specified here is used as the default folder when you export data in Excel format SLK Click on the folder button to navigate to the desired folder Data Path The folder specified here is used to store the acquired data from the loggers Click on the folder button to navigate to the desired folder TecnoSoft s r l TSR 11 17 Alarm Profiles Here you can create several profiles to set alarms to each radio sensor connected To see the details for a profile just place on it the cursor and wait for the tooltip to show Add a Profile Just click on the plus sign to open a new window where you can set the Name of the profile the Max and Min thresholds for the alarms the Hysteresis Hyst for the two values and the Waiting Time meaning for how long the temperature must be out of threshold before actually giving the alarm Remove a Profile To remove a Profile from your list select it form the drop down list and click on the Remove Profile button the rubber button next to the plus sign Printing Options Here you can set the headings for the report to be printed Heading 1 The title of the report Heading 2 The sub title of the report Heading 3 Additional information text to be printed on the report AutoSave Here you can enable the option for automatic save of the data this function is particularly suggested for long time processes or continuous monitoring
Download Pdf Manuals