1.                         m   serpentine  tube  G 74   inlet and outlet    Flue outlet diameter mm 150                The firewood parameters as main recommended fuel type for combined wood gasification  hot water boiler from series  3Fera  are presented in Table 3 3     Table 3 3  Recommended fuel parameters     dry firewood                             Parameter Dimension Value  Fuel type Firewood  Moisture 96  lt  2096  Minimum fuel caloricity  minimum calorific value  MJ kg 213 9  kWh kg  gt 3 9          Table 3 4 represents the parameters for wood pellets as type of fuel for hot water boilers    from series  3Fera        3Fera 25 35 45       Table 3 4  Wood pellets parameters                 Parameter Dimension Value   Diameter of the granules mm 6 8  Recommended fuel caloricity  net calorific value  MJ kg  gt 17 2  kWh kg 24 7       Wood pellets category according to standard EN    14961 2    ENplus A1  ENplus   A2  ENplus B       Wood pellets category according to the appliance    manufacturing company categorization    A  AB  B  BC  C  CD     E EF          Moisture               Max  8     10        The parameters for dry calibrated wood chips as type of fuel for hot water boilers from series       3Fera    are presented in Table 3 5     Table 3 5 Dry calibrated wood chips parameters                                      Parameter Notation Dimension Value  Typical size of dry calibrated wood chips P mm 20  Moisture     W  96  lt  10  Ash content A 96  lt  1 5  Bulk densit
2.       MANUAL    FOR OPERATION OF COMBINED WOOD GASIFICATION   HOT WATER BOILER  UTILIZING WOOD LOGS  WOOD   PELLETS AND DRY CALIBRATED WOOD CHIPS  FROM  SERIES    3Fera 25 35 45       http    www greenecotherm eu                            Manufacturer ZMM Haskovo PLC    Address 67 Saedinenie  6300 Haskovo  Bulgaria  Telephone  359 800 15 145   Fax  359 38 603070   e mail greenecotherm erato bg   home page www greenecotherm eu                The manufacturing company thanks you for the contribution of your choice     The manufacturing company provides this manual in help to the team that will install  adjust  and service this system  as well as to the customer that will operate it     The manufacturing company requires that the technicians performing the above presented  procedures has passed training course for the activities performed with the product     User manual for operation and installation of combined wood gasification hot water boiler  operating  with wood logs  wood pellets and dry calibrated wood chips  from series  3Fera 25 35 45    Edition  21 12 2012     05 44 00         3Fera 25 35 45 2    page  1  INFORMATION RELATED TO THE USERS SAFETY              sss 4  2  DESRIPTION AND ADVANTAGES OF COMBINED WOOD GASIFICATION HOT WATER  BOILER FROM  SERIES S FERA                         5  3  TECHNICAL DATA FOR COMBINED WOOD GASIFICATION HOT WATER BOILER FROM  SERIES    FERA i Iis asso eerie o inh rea Ce EE ye a pde p baa      E Ta ea nae               Rag              
3.    7  4  CONSTRUCTION DESCRIPTION OF COMBINED WOOD GASIFICATION HOT WATER  BOILER  FROM  SERIES     FERA     uuu a                          idera ana pa Pea ea      10  5  MOUNTING AND INSTALLATION OF THE BOILER                 sssseeseseeeneeerenn nennen 17  6  INITIALIZATION OF THE APPLIANCE IN OPERATION                  essere 23  6 1  GENERAL REQUIREMENTS ABOUT THE USED FUEL                      ener 23  6 2  GENERAL REQUIEMENTS DURING OPERATION OF THE HEATING INSTALLATION     23  6 3  INITILIZATION OF HOT WATER BOILER FROM SERIES                  IN OPERATION            24  6 3 1  ADJUSTMENT OF THE FIRING AIR FLOW RATE THERMO REGULATION VALVE            25  6 3 2  INTERFACE CONTROL PANEL OF HOT WATER BOILER FROM SERIES                            26  6 3 8  BOILER POWER SUPPLY  u                                 27  6 3 4     BOILER SWTICH ON    ku      ere eoe eee u era                        28  6 4  CHANGING THE BOILER OPERATION PARAMETERS                                                     30  6 5  PARAMETERS FOR ADJUSTMENT OF THE BOILER OPERATION                                     32  6 5 1  OPERATION OF THE BOILER WITH FUEL   MANUAL REFUELING WITH FIREWOOD     32  6 5 2  OPERATION OF THE BOILER IN COMBINED MODE   AUTOMATED FEEDING WITH  WOOD PELLETS OR DRY CALIBRATED WOOD CHIPS                                                      34  6 6  ADJUSTMENT OF THE BOILER HEATING OUTPUT               sese 36  6 6 1  OPERATION MODE DURING FIREWOOD UTILIZATION                 
4.    eene 36  6 6 2  BOILER OPERATION IN COMBINED MODE                                        nnns 37  6 7  STOPPING THE BOILER QOPERA TION                                    a nennen enne 38  6 7 1  BOILER EMERGENCY SHUT DOWN                                                                   39  6 8  BOILER  SHUT DOWN A u eite Heide eas nu Hee        Qu Dn ee 39  6 9  BOILER  CEEANING              m iha k               W Sua clea ele eden   39  6 10  USER INTRODUCTION WITH THE SERVICING AND ADJUSTMENT PROCEDURES OF  THE BOILER  E 41  6 11  SAFETY AND UNPREDICTED RISKS                     nennen enn enne 41  6 12  ACTIVITIES AFTER THE APPLIANCE LIFE CYCLE EXPIRY                                                42  7  FAILURES AND TROUBLESHOOTING                               l n    43  8  WIRING DIAGRAM OF THE APPLIANCE                     n n    45  9  WARRANTY CONDITIONS                                                                          nn nnns 47             25 35 45 3    CONTENT    1  INFORMATION RELATED TO THE USERS SAFETY     The manual book for operation of combined wood gasification hot water boiler from series                   is designated for users and authorized servicing specialists     The user must know that      All activities related to the heating installation must be performed only by authorized  installers  which have acquired legal rights for such activities from the local  authorities      All activities related to the electrical installation must be p
5.  3Fera 25 35 45 46    Figure 8 2  Schematic wiring diagram of the appliance  control board        9     WARRANTY CONDITIONS     The warranty period of combined wood gasification hot water boiler from series                  starts  considered from the date of completing and stamping its warranty card        THE PRODUCT WARRANTY IS NOT VALID in the following situations     Damages over the appliance caused by improper storage  transport and or unloading   which are not organized by the manufacturing company    Failures caused by natural disasters  earthquakes  fire  floods and others     The requirements for installation  operation and periodical maintenance  presented in  the current manual book  are not observed    Attempts for removing any defect  performed by the buyer or other unauthorized  persons    Changes over the appliance construction    Incorrect heating calculations and project design for mounting and installation of the  boiler    Failures for which the manufacturing company is not responsible  which are not under  its control    Malfunctions and damages which are not caused by the boiler itself  but have led to  failure in its construction     Every warranty repair must be written in the product warranty card     The warranty period is interrupted for the period of time from the date of registering the  warranty claim up to removal of the failure     The warranty period of the product is 24  twenty four  months     The warranty is valid only when the purchase in
6.  assigned  temperature value       High heating output of the  boiler    It is necessary to decrease the  fuel quantity or the firewood refuel  frequency of the boiler       3    Overheating of the  boiler    Lack of heating load or  incorrect adjustment of the  boiler heating output or  the operation of the  heating installation    Correct operation inspections  must be performed over the  heating installation and eventually  adjustment of the operation  parameters     to be performed by  specialist  After cooling of the  appliance and removing the  problem source  the emergency  thermostat must be deactivated   remove its protection cover   press the button and put the  cover back   and after that the  boiler can be started again        4    The flame is  dark  and  the chimney smokes  dark    Low quality fuel  moisture  more than 20      Fuel replacement is required  whit  such that corresponds to the  required parameters       Improper adjustment of  the appliance parameters    Adjustment of the appliance air  distribution is required       5  Presence of unburned  fuel in the fuel chamber    Inefficient fuel burning    Adjustment of the firing air  distribution is required          6    High flue gas  temperature  if a  thermometer is          Dirty heat exchanging  surfaces       Cleaning of the boiler   s heat  exchanging surfaces is required       3Fera 25 35 45    43          installed        7  Condensation of the  water vapors over the  combustion chamber  heated s
7.  installation of  additional flue gas extraction fan  and or change of the chimney                       thermostat  11    Another  not presented Consultation with and or  failures intervention of servicing  technician is required   3Fera 25 35 45 44       8  WIRING DIAGRAM OF THE APPLIANCE     The wiring diagrams for connecting combined wood gasification boiler from series    3Fera     are presented on Figure 8 1 and Figure 8 2     Figure 8 1  Schematic wiring diagram for connecting the appliance to the main power supply           Motors  thermostat   plates              2  220V      Overheat          3Fera 25 35 45 45           sensor presence of burning process   input flame sensor  I3   Start  I6     Manual ignition  amp  only wood gasification   combine process    POWER SUPPLY UNIT    I8     sensor  pellets level capacitive sensor               POWER STEP PS 1AC 24DC 0 5 Ll  1   T   A    emergency thermostat   alarm thermostat H O SUPPLY UNIT PHOENIX CONTACT 220V  T   W  operation thermostat   boiler thermostat       24 V St  24V St     T  R   room thermostat GERMANY 2   3   24 V  St                m     TR SB2 Capacitve  Oo D       6 E 8 Sensor  TW  P   option   L1  1  220Vac 7 D     24 V St     24V St  PROCESS  CONTROL  1  SB1  Start      SB2  Manual  ignition  amp  only pyrolisis    combine process  220Vac 220          2  4  24V St          Alarm Manual      External pellet  transport auger      ignition Flue gas  Fe g a  I     amp  2    OK extraction option  air fan 
8.  is stopped from operation entire cleaning of the ash residues   over the heat exchanging surfaces of the boiler  must be performed  because the  ash has corrosive influence over the steel surfaces  which decreases the  appliance life  At the end of the heating season it is necessary to perform not  m only cleaning  but also prophylaxis by specialized servicing company  which   evaluates the boiler condition and may take further measures for repairs and parts  replacement  The prophylaxis provides availability for inspectional checks and  evaluation of the appliance  and also to perform measures for replacement of    defective and worn modules or components  Observance of these procedures  provide longer life and reliable operation of the boiler        6 7 1  BOILER EMERGENCY SHUT DOWN     During the boiler operation emergency situations are possible to occur  exceed of its tolerable  operation temperature      this is followed by activation of the emergency thermostat  which  activates if the boiler is overheated and also the  Emergency overheating  indication lamp   positioned on the boiler s control panel  lights  It is necessary to take measures for removing the  reason for overheating and for gradual cooling  After the boiler cools down its emergency  thermostat cap has to be removed and the button inside has to be pressed  by using sharp tool    in order to switch it on again  and finally the protection cap must be placed back in primary  position  The boiler must be in
9.  manufacturing company  method      A  AB  B  BC  C  CD  E  EF       Dry calibrated wood chips  category  according to  standard EN 14961 1      Annex 2  P16  M10    0 7       Firewood consumption at                             kg h 7 9 11 1 14 2   nominal heating output  Wood pellets consumption kg h 56 78 10 1  at nominal heating output  Dry calibrated wood chips  consumption at nominal kg h 6 1 8 6 11 0  heating output  Sce at nominal   93 0 93 0 93 0   eating output  Wastes from the fuel ash The quantity depends on the fuel ash content    burning             The dimensions and technical parameters of combined hot water boiler from series    3Fera       are presented in Table 3 2     3Fera 25 35 45       Table 3 2  Dimensions and technical parameters of combined hot water boiler from series                                                                       SFera    Parameter Dimension Value   Boiler model   3Fera 25 3Fera 35 3Fera 45  Weight kg 418 438 485  Fuel chamber volume   120 160 160  Water volume   126 150 200  Overall size of the boiler WxHxL mm 800x1100x1150   800x1100x1250   800x1200x1250  Max  operating pressure bar 2 0  Recommended operation water    80 85  temperature  Minimum temperature of the inlet   C 60  water  Chimney draught Pa 18   24  Supply voltage   50Hz  230V  Expansion tank type in the _ Opened or closed  installation  Environment protection index   IP20 IP20 IP20  Connection   Inlet outlet water     li   G 11 2  inks pipes   Drain pipe G 1 2 
10.  mounted and a wall must be at least  400 mm     3Fera 25 35 45 17       o The minimum distance from the left and right sides of the reserve fuel transport  auger to a wall must be at least 500 mm  in order to ensure free access to its  manhole cover and to the boiler rear side as well    o The minimum free area above the fuel transport auger must be at least 600 mm  in  order to ensure easy access for servicing of its control components and to its gear  cover     After the boiler has been positioned at its designated place  the following activities for its  equipment and preparation must be completed     Mounting and positioning of the fireclay component in the boilers combustion chamber   Figure 5 1 and Figure 5 2      Figure 5 1  Directional fireclay made component  which must be positioned in the boiler   s  combustion chamber                    Figure 5 2  Picture of correctly positioned directing fireclay made component  mounted in the  boiler   s combustion chamber           3Fera 25 35 45 18      Installation of the firing air flow rate thermo regulation valve  Figure 5 3      Figure 5 3  Thermo regulating valve for the firing air flow rate adjustment                       The thermo regulation valve for the firing air flow rate is mounted and is linked with a chain which  moves the flap for regulation of the boiler air intake           Installation of the safety temperature valve that supplies water for emergency cooling of  the boiler  in case the circulations water
11.  of the upper limit of the circulations  water temperature        hermo manometer     serves for indication of the circulations water temperature and  pressure      Operation mode switch     operation as normal wood gasification boiler or as combined   operation with firewood and after its complete burning the system automatically switches  to reserve fuel operation       Controller     module for management of the boiler operation     serves for boiler  management  according to preliminary installed program      Alarm overheating     serves for indication of the emergency thermostat activation  due to  exceeding of the emergency temperature of the water in the boiler  overheating       Controller alarm  interference during operation      serves for indication of failure alarm and  emergency situations      Ignition OK     indicates operation and lights in presence of burning process     3Fera 25 35 45 26    An interface panel with connectors is mounted on the back side of the combined wood gasification  hot water boiler from series  3Fera   Figure 6 2      Figure 6 2  Interface panel with connectors of hot water boiler from series  3Fera                              Interface panel components and their functions    Flue gas extraction fan     connector for plugging the flue gas extraction fan    External auger  option      connector for plugging additional auger    Combined fuel transport auger  option      connector for plugging the auger    Switch POWER   serves for centra
12.  restart the appliance  and the alarm will reset automatically     6 5  PARAMETERS FOR ADJUSTMENT OF THE BOILER OPERATION   6 5 1  OPERATION OF THE BOILER WITH FUEL   MANUAL REFUELING WITH FIREWOOD     For this operation mode the switch POWER must be ON  The mode switcher is in wood logs  gasification mode  pyrolisys   then the switch START must be on  the flue gas extraction fan starts  to operate   the wood logs must be fired manually  The lighting of the green lamp  after period of  time when the flue gasses reach certain temperature  is a signal that stable burning process is  achieved  The boiler operation thermostat has to be positioned between 65   C   80   C and the  contact from the room thermostat has to be closed           If a room thermostat is not installed its connector must be left in the interface panel  d  plug  with a brindle  the brindle is factory installed and has to be removed if a room    thermostat will be installed         The firing air flow rate is essential about the boiler operation mode and its efficiency     when the  air quantity is less than the optimum  this insufficiency leads to incomplete fuel combustion and  also to separation of health harmful substances in the flue gasses  one of the harmful emissions is  the carbon oxygen   When the air consumption is higher than the optimum  it leads to cooling of  the burning zone and again to incomplete fuel combustion  Therefore the necessary air quantity  has to be supplied to the boiler     The 
13.  temperature has been exceeded above the limits     The temperature safety valve   s sensor has to be screwed in a muff  positioned at the upper part of  the boiler heat exchanger  The temperature safety valve   s operation module must be screwed in  one of the two ends  depending on the installation availability  of the emergency cooling boiler  tube  serpentine      Figure 5 4  The inlet side of the temperature safety valve must be linked to  the water supply pipeline  that supplies fresh clean water  or to another source of clean water  under pressure  The outlet side of the emergency cooling boiler tube  serpentine  must be linked  to a drain pipe  so the outlet water can easily and safely flow to the sewers     3Fera 25 35 45 19    Figure 5 4  View of the boiler with shown ends of the emergency cooling boiler tube  Serpentine              Emergency cooling  boiler tube   input output                   The inlet and outlet pipelines of the heating installation must be connected to the relevant  boiler muffs  Figure 5 5      Figure 5 5  View of the boiler with shown muffs for connecting to the heating installation and its  outlet to the chimney                      Positioning of the boiler in compliance with the requirements for connecting to the electrical  supply network     the appliance must be positioned so free access to the socket box is  guaranteed  230V 50Hz      3Fera 25 35 45 20          The completion of the installation works and the hot test of the boiler mu
14.  that if the boiler has been operated more continues without attendance of the    3Fera 25 35 45 24       servicing personal  the firewood in the fuel chamber may  overarch  and eventually to block the  fire nozzle inlet  which reflects the burning process and decreases the boiler heating output   Therefore it is recommended to stir the fuel in the chamber  the coals also  periodically and to  clean the nozzle orifice  by using specialized tool     rabble  by observing the personal safety  measures   Such actions will improve the burning and wood gasification processes     6 3 1  ADJUSTMENT OF THE FIRING AIR FLOW RATE THERMO REGULATION  VALVE     The thermo regulation valve for adjustment of the air quantity  needed for effective burning  process  must be adjusted when the boiler operates at nominal heating output        The thermo regulation valve serves for adjustment of the air quantity  needed for achievement of  effective burning process  This valve also serves as protection from overheating  The valve  indicates the circulations water temperature in the boiler  by changing the position of a lever from  its construction  When the water temperature is low the lever opens the air regulation flap and  when the temperature starts to increase  the lever moves and partially closes the flap  i e  the  TRV does not need outer energy source for operation   The position of the firing air flap  moved by  the thermo regulation valve  can be checked visually        The thermo regulat
15. In case of necessity the system can be refilled  toped up  with water  but only when the boiler is in  cold condition  This is necessary in order to prevent the steel made heat exchanger of the boiler  from damages  caused by thermal stresses by the intake of cold water     In case the boiler and the heating installation will not be operated for long period of time and there  is possibility of local circulations water freezing  then it is recommended to drain the water out of  the system  It is also good to know that the presence of water in the heating installation and the  boiler protects the steel surfaces from contact with the air oxygen and respectively from corrosion     3Fera 25 35 45 23       6 3  INITILIZATION OF HOT WATER BOILER FROM SERIES    3Fera    IN OPERATION     The following requirements must be observed during initialization of combined wood gasification  hot water boiler from series  3Fera      The boiler servicing handling must be performed in compliance with the maintenance and  operation manual     The boiler must be serviced  handled only by adult people  which are well familiar with the  operation manual of the appliance           A Presence of children near the boiler is not allowed                 intervention over the boiler operation  which may lead to danger for the servicing  personal health or other indirectly related persons is not allowed      Incase easy flammable gasses may penetrate come in the boiler room  also during repairs  which can b
16. adjustment of the burning process is performed by adjustment of the firing air flow rate and its  distribution  The firing air is sucked to the fuel chamber and to the combustion nozzle by the flue  gas extraction fan  This air is distributed through a manifold  where it is being preheated and then  transferred to the fuel chamber  this is the so called  primary air   and the combustion nozzle  the  so called  secondary air    The adjustment of the primary and secondary air distribution ratio is  performed by a regulation flap  positioned over the firing air flap inlet   The primary air  which is  sucked to the fuel chamber  is used for the wood gasification process  The secondary air is used  for burning of the combustible  volatile  gasses  separated from the wood gasification process and  transferred through the boiler s nozzle     The firing air distribution ratio adjustment can be performed by changing the position of the  primary air regulation flap and also by the common air quantity regulation flap  consummated for  the burning process     A small movement of the flap significantly affects the primary air quantity  i e  the adjustment is  very sensible  Therefore every change of the firing air adjustment must be performed very  carefully and to wait enough time  at least 30 minutes   so the change influences the boiler  operation mode  If fuel with higher moistureis used the primary air has to be increased  by  opening the primary air flap gradually  step by step   wh
17. ciency  This may also lead to condensation of the water vapor   which is final product from the fuel combustion     Continues operation of the appliance with heating output below the minimum  as presented in the  boiler specification  is not recommended  because such operation modes are not efficient and  economic  and may also create conditions of excessive harmful and hazard chemicals separation   mainly carbon oxide   which might endanger the people s life and also to decrease the appliance  resource  tars which condensate over the heat exchanging surfaces and cause corrosion      In nominal heating output operation the boiler has to be refueled periodically  by performing the  following procedure     Wait for around 5 10 seconds  after that open the fuel chamber door  It should be opened  on stages  First open it slightly  to get a small gap  through which the surrounding air can  flow in  but do not allow extraction of flue gasses out of the door     After that open the fuel chamber door completely and refuel with firewood  The refueling  should be performed carefully     keep the skin from burning or and intake of gas  It is  recommended to work with personal safety equipment  The firewood has to be loaded in  the chamber parallel and longitudinal to the firing nozzle  so the chamber volume is filled to  maximum  Before loading the new fuel it is recommended to mix the burning remains    3Fera 25 35 45 36    around the nozzle  in order to ensure free gas flow through it
18. door  lower boiler  door  and quick assessment of the flame color  After that the door must be closed        The flame coming down from the nozzle must reach the directing fireclay component  positioned  on the bottom of the combustion chamber  The flame color at optimal burning process  process  realized with low excess air and minimum harmful emissions concentration in the flue gasses      mainly carbon oxygen  CO   nitro oxygen  NO   and unburned carbon hydrogen  is deep yellow  with bluish  blue  areas     In case the flame is      Deep red     this shows insufficient secondary air     it is necessary to increase the  secondary air flow rate  by opening the flap      Bright yellow or with small length     this is indication for excessive secondary air and its  flow rate has to be decreased  by gradual closing of the common air regulation flap  driven  by the chain of the thermo regulation valve      Flame with low intensity  slow flame      indicates that the primary air flow rate has to be  increased     the primary air regulation flap has to be opened gradually      Smoke in the flame     indicates insufficient secondary air and increased production of  combustible gasses and tars  Therefore it is necessary to decrease the primary and  increase the secondary air flow rates  after waiting for a period of time     this is performed  by closing the primary air regulation flap  move its shaft gradually towards the boiler      Criterion for optimal combustion is the conditio
19. e accompanied by separation of gas  for example coating with flammable  paints and materials  flooring   the boiler must be shut down from operation      During the boiler operation it must be periodically checked by the servicing handling  personal  the user              user must not perform repairs over the appliance  In case of failure during the boiler  operation the solution can be found in the troubleshooting table  presented in this manual   or eventually to ask for assistance by servicing company             changes over the boiler construction and electrical installation are strictly forbidden      Usage of unspecified for the boiler fuel is forbidden      Increasing the boiler heating output over its nominal output and also its overheating are  forbidden      Positioning of easy flammable materials near or next to the boiler  at distance shorter than  the safe is forbidden             ash residues from the burning process must be collected in fireproof containers with  covers and after cooling to ambient temperature they must be dumped at proper for the  purpose places  During the ash removing from the boiler presence of flammable materials  at distance less than 1500 mm from the appliance is not allowed  The ash from firewood  utilization can be used for soil fertilization      After every heating season the boiler and the chimney  to which it is connected  must be  cleaned from the ash  soot and tar deposits      The period length of burning depends on the operat
20. e the heating output and the operation mode of the appliance for the relevant fuel  wood  pellets or dry calibrated wood chips   If the fuel type is changed the parameters T4  C1 and T7  should be changed too     3Fera 25 35 45    35          6 6  ADJUSTMENT OF THE BOILER HEATING OUTPUT     6 6 1  OPERATION MODE DURING FIREWOOD UTILIZATION     After completion of the boiler starting process  the fuel is successfully fired  stable process of fuel  gasification is monitored and stable fuel burning process in the combustion chamber   the boiler  has heated the circulations water and the heating installation is equally tempered  it can be  accepted that the appliance is in nominal operation mode  In such mode the burning process and  other control elements can be adjusted  In such mode the circulations water temperature in the  boiler must be in its operating range     from 65 to 85  C  It has to be rendered into account that the  boiler refueling is manual and is required periodically  which might lead to slight imbalance   change  of its operation parameters  as well as to the heating system  in dependence on the  refueling frequency and the fuel quantity      If a circulations pump is used for transferring the heat energy from to boiler to the heating  installation  the reverse water temperature  cooled water  from the system should not be lower  than 60 C  because it is possible to cool down the flue gasses in the boilers heat exchanger and  to decrease significantly its effi
21. erformed only by  electricians      The initialization of the appliance in operation  including visual check of the heating  installation  adjustment and boiler start up  must be performed by certified technician   authorized by the manufacturing company representatives     Please observe the following rules during installation  initial start up  adjustment and  operation initialization of combined wood gasification hot water boiler from series  3Fera        All legal provisions related to the safety techniques      Environment protection provisions      Installation  initial start up and adjustment provisions      The harmonized EU provisions  applicable in the relevant country     Please strictly observe the presented safety instructions  in order to avoid risks and harms to  people  properties  as well as to environment polluting     Please pay attention to the following symbols from the current manual book        3Fera 25 35 45 4    2  DESRIPTION AND ADVANTAGES OF COMBINED WOOD GASIFICATION HOT  WATER BOILER FROM SERIES    3 Fera      The steel made combined wood gasification hot water boilers from series  3Fera  are  designated for heating and or providing hot domestic water of single family houses  offices   business buildings and others     The boiler represents welded steel construction  optimized for high efficiency and economic  operation  and also for easy servicing and cleaning  The reliable steel made construction of  the boiler is specially designed for firing o
22. es   SFera  with shown flue gas and ash directions            WteTeTaYuTeTaY wv sig    2 i Me          F                            3Fera 25 35 45 13    Figure 4 5  Overall sizes of combined wood gasification hot water boiler from series  3Fera         800 1223       1221                                  Exploded view of the combined fuel transport auger  offered as an option   used for feeding  combined wood gasification hot water boilers from series    3Fera    operating with reserve fuel   wood pellets or dry calibrated wood chips   is presented on Figure 4 6     3Fera 25 35 45 14    Figure 4 6 Exploded view of combined fuel transport auger                    1  Cover 7  Pipe   2  Chain gear     auger 8  Auger Screw   3  Chain gear   flap 9  Shut down device  4  Chain tensioner 10  Moving cover   5  Sectioned dozing flap 11  Motor gear   6  Body    Figure 4 7 presents the dimensions of combined fuel transport auger for feeding of combined hot  water boilers from series  3Fera   with wood pellets or dry calibrated wood chips     3Fera 25 35 45 15    Figure 4 7 Dimensions of combined fuel transport auger             125                     25 35 45    16       5     MOUNTING AND INSTALLATION OF THE BOILER     The following requirements must be observed during the mounting and installation of combined  wood gasification hot water boiler from series  3Fera      The room designated for the boiler installation must provide constant air intake  which is  needed for the burning pr
23. f dry wood  with moistureup to 20   and for other  type reserve fuel  wood pellets or dry calibrated wood chips  by fuel gasification with  maximum efficiency  economic operation and easy servicing  Its manual initial firing and the  automatic switching to reserve type of fuel provide comfort  approaching the electrical  heating  diesel fuel or natural gas heating     The generated heat energy is acquired by the boiler body heat exchanging surfaces and is  transferred to the heat carrier  in most cases circulations water  in the heating installation or  to the hot domestic water system     The appliance can utilize the following types of fuels      Firewood with the following parameters    o Clean firewood  Usage of materials with improper impurities as paint  lacquer  coatings  organic or non organic substances is not applicable    o The firewood logs length must correspond to the boiler fuel chamber depth    o Thecross cut  diameter  of the firewood must be  D  lt  200mm    o The fuel moisturemust be  W   lt  20       Wood pellets with diameter    6 8 mm  category ENplus A1  ENplus A2 and ENplus   B according to standard EN 14961 2 2010 or category  A  AB  B  BC  C  CD  E  EF  according to the methodic developed and used by the appliance manufacturing  company      Dry calibrated wood chippings with main fraction size P 20mm  moisture W s10 0   and ash content A  S2 0   This fuel must correspond to the requirements of standard  OENORM M7133 G30  W10  ash class A1 or A2  Acc
24. ich will ensure optimal wood gasification  process           The adjustment of the boiler heating output parameters must be performed  by trained user personal  and in order to achieve it a gas analyzer should be used        The primary air flow rate  which can be adjusted by changing the flap position  determines the  quantity of air needed for maintaining the wood gasification process of the fuel  loaded in the  upper boiler chamber  The flap is used to regulate the intensity of wood gas separation and  respectively its adjustment partially reflects the boiler heating output     3Fera 25 35 45 32             The secondary air flow rate can be changed by changing the primary air flap position  By opening  it the primary air flow rate increases and the secondary air decreases  The air is transferred  through the preheating box  then through the nozzle orifices and mixes with the combustible  gasses  separated from the wood gasification  which results in optimum combustion and  production of heat energy     The total air quantity sucked by the boiler is determined by the flap position  driven by the thermo   regulation valve  The valve changes the common air regulation flap position  its tilt  by chain  The  burning process adjustment must be performed by trained specialist and gas analyzing device     For primary adjustment of the burning process it is necessary to perform visual evaluation of the  flame color     it is performed by slightly opening of the combustion chamber 
25. iod it reaches high values  which leads to clogging of the chimney pipelines and sensible  decrease of the chimney draught     3Fera 25 35 45 40       Figure 6 7  Cleaning of the boiler   s tube bundle and fire grate                    1  Inlet for cleaning of the boiler   s tube bundle  2  Fire  grate    The tube bundle cleaning has to be performed with steel brush  by carrying it through the top  opening to the bottom of the tract  At the end  after the cleaning  the ash residues have to be  scraped out from the boiler   s tube bundle bottom zone        6 10  USER INTRODUCTION TO THE SERVICING AND ADJUSTMENT PROCEDURES OF  THE BOILER     The user must be well introduced to    The appliance operation manual    How to operate the appliance    How to adjust and regulate the boiler    The methodic for servicing handling of the boiler   How to clean the combustion and fuel chambers   How to clean the boiler s tube bundle     6 11  SAFETY AND UNPREDICTED RISKS     Risks related to the appliance usage     The combined wood gasification hot water boiler from series  3Fera  is designed and  manufactured in compliance with the major safety European standards and directives     3Fera 25 35 45 41    Danger conditions may occur in the following situations       The combined wood gasification hot water boiler from series  3Fera  has been  improperly used             appliance is installed by unqualified personal      The instructions for safe usage  presented in this manual  are not obse
26. ion mode and also on the used  firewood quality  The resinous wood with medium and low quality may lead to excessive  tar contamination of the fuel chamber  The fresh wood material  which is not dried to the  required parameters  has low caloricity and respectively leads to increased fuel  consumption  compared to the nominal consumption  and also to sensibly lower boiler  heating output  This type of fuel may also lead to excessive contamination of tar deposits  and corrosion of the heated surfaces     The combined wood gasification hot water boiler from series  3Fera  is appliance with manual  loading of the primary fuel     firewood  Its heating output depends not only by the fuel  characteristics  mostly its water content   but also by the operating mode  Practically effective  wood gasification process in such type of boilers can be achieved if the circulations water in the  boiler heat exchanger is over 60    C  Therefore such conditions must be provided during its  operation  If the circulations water temperature is lower  it leads to decreased intensity of burning  gas separation from the wood and also to condensation of these gasses over the heat exchanger  unit walls  This is highly unpleasant process with regards to the boiler life time  because the tar  condensation have corrosive influence and this process leads to decreasing the boiler walls  thickness  respectively its life time  in other words it leads to leaks from the heat exchanger unit    The practice show
27. ion valve adjustment can be performed by the following method      The boiler operates until the circulation water reaches 80  C  indicated by the thermo   manometer gauge  positioned on the front control panel of the boiler       The handle position of the thermo regulation valve must be adjusted to temperature value  equal to the boiler circulations water      The chain has to be adjusted  which connects the TRV lever with air regulation flap  by  moving its hook  so the flap is opened but to position limited by the screw  that provides  the minimum clearance of the flap  The chain must be stretched       f it is necessary to adjust the minimum firing air flap opening clearance  as it can be  performed by the adjusting screw        3Fera 25 35 45 25    6 3 2  INTERFACE CONTROL PANEL OF HOT WATER BOILER FROM SERIES     3Fera        The management of combined hot water boilers from series    3Fera    can be performed by its  interface control panel  equipped with controlling and managing devices  and with interface panel  with connectors     Figure 6 1 represents the interface controller front panel for management of hot water boilers from  series  3Fera      Figure 6 1  Interface control panel with controlling and managing devices for hot water boiler from  series                         Interface panel components and their functions      START   serves for submitting    START STOP    command to the control module      Operation  boiler  thermostat     is used for assignment
28. l boiler ON and OFF switching    Emergency thermostat     serves for overheating protection of the boiler  Factory adjusted  to close when the boiler water temperature exceeds 95 C    Room thermostat     connector for plugging a room thermostat to the boiler    Power supply     connector for plugging the boiler to the main electrical supply     eno po      c               6 3 3  BOILER POWER SUPPLY       The boiler must be connected to electrical power supply installation by observing the  safety technique rules     Before the manual firing of the initial firewood in the fuel chamber of the boiler  it is  necessary to check the boilers components modules functionality  which provide its  reliable operation and to the heating system s also   o Flue gas extraction fan   o Firing air flap   o Position and condition of the directing fireclay made component  located in the  boiler combustion chamber     3Fera 25 35 45 27    o Thermo regulation valve for adjustment of the firing air flow rate and also its  adjustment    Managing and indication devices functionality  thermostats  thermo manometer    Doors sealing    Circulations pump  if installed in the heating installation     Combined fuel transport auger     O  OQ O O    The fuel chamber has to be loaded with small quantity of firewood sticks  dry sticks  branch  timber  wood splinters   by forming a pile over the nozzle zone  positioned in the lower part of the  fuel chamber  It is recommended that the total weight of the wood 
29. n of the directing fireclay component  mounted in  the boiler   s combustion chamber     its surface must be white to light grey color  the ash deposits  quantity should be relatively little  without presence of unburned particles  coals and others  or  dark colored wooden particles      The burning process adjustment can be also evaluated by monitoring the smoke color  exhausted  from the chimney to which the boiler is connected  If the smoke is dark it means that the  secondary air is not enough or the fuel moistureis high  The chimney smoke is usually visible  as  mainly the sun lights break through it due to the smoke gas higher temperature  compared to the  environment   In other cases  when the temperature is below  10 C  it is possible to monitor    3Fera 25 35 45 33    condensation of the water vapors in the flue gasses  which is visualized as white smoke  coming  out from the chimney        6 5 2  OPERATION OF THE BOILER IN COMBINED MODE   AUTOMATED FEEDING WITH  WOOD PELLETS OR DRY CALIBRATED WOOD CHIPS     The main parameters which take part in the adjustment of combined wood gasification hot water  boilers from series    3Fera    are presented in Table 6 1     Parameters change should be performed only by authorized technicians  which are well familiar  with the appliance operating processes        3Fera 25 35 45 34    Table 6 1  Main operation parameters determining the appliance heating output in combined fuel  feeding mode        Parameter    Description    3Fe
30. n the range of 65  C   80  C  in order to prevent the appliance from  low temperature corrosion     3Fera 25 35 45 29             6 4  CHANGING THE BOILER OPERATION PARAMETERS        Outside view of the boiler   s interface panel control module is presented on Figure 6 3     Figure 6 3  Outside view and notation of the control module buttons     5       dea    In the next lines is presented the algorithm for visualization and relevant change  only if  necessary   of parameters from the customer allowed access group     1  Press the green button  e  marked as Menu OK on the controller  A list of menus appears     2  With buttons arrow up  V  or down  A  from the menu choose the option       PARAMETER        3  Arrow up  A  must be pressed several times until reaching the desired timer for     T4 or T6   these are the parameters defining the appliance heating output         4  With button arrow right  f  choose the field in which the time is marked     the value of the  chosen parameter  the digits start blinking  i e  they expect change      5  With button arrow down  V  or up  A  the value can be changed     Note  If the buttons arrow down  V  or up  A  are hold continues the values start to  change quicker     6  After adjusting the desired time the button Menu OK must be pressed   7       the control module display appears message    CONFIRM CHANGES      By the arrows  down  V  or up  A  position the mark over    Yes    or    No     Choose  Yes  by pressing the    green but
31. ocess and for good ventilation    Installation of the boiler in living premises  including corridors  is not allowed    The boiler connection to the heating installation must be performed only by qualified  technician    The installation and maintenance of solid fuel hot water boilers must be performed by  specialized companies  which have acquired legal rights for performing such activities    The combined hot water boiler from series                  can be connected to the heating system  with opened or closed expansion tank  which has to be calculated during the installation  project development    The combined hot water boiler from series  3Fera  is connected to the heating system with  OPENED or CLOSED expansion tank type  In case the system is with closed type  expansion type a safety pressure valve must be installed  which opens if the boiler  operation pressure exceeds  0 25MPa   This valve must be certified according to PED  97 23    Before initialization of the boiler in operation  the entire heating installation must be filled  with water and air freed  eliminate the air     The boiler servicing  handling  must be performed only by adult persons  which are well  familiar with the appliance operation manual           During the boiler transportation precaution measures must be taken  against  damage or braking of the fireclay component  which is positioned in the boiler s    combustion chamber        The boiler installation requires preliminary developed project  c
32. omplying with the acting norms and  prescriptions     For the heating system   BDS EN 303 5 2000    Central heating hot water boilers     part 5   hot water solid fuel boilers with maximum nominal heating output up to 300 kW      terminology  requirements  tests and notation    For the chimney   Fire safety prescriptions   For the electrical supply system   BDS EN 60 335 1 1997    Safety of domestic electrical  appliances    The opened area  for supplying the boiler room with fresh air  must be at least 0 04 m     The positioning of the boiler for easy manipulation  without combined fuel transport auger   which is offered as an option  must comply with   o The boiler must be positioned over inflammable pad with minimum height of 50  mm   o The minimum distance for manipulation in front of the boiler must be 1000 mm   o The minimum allowed distance between the boiler rear side and a wall must not be  less than 400 mm   o The minimum distance between the boiler left and right side to a wall must be 500  mm  in order to ensure free access to its side cover panels and its rear side   o The minimum distance of the free area over the boiler must be at least 600 mm  in  order to ensure easy access to its control components and cleaning of the  convection pipeline     Positioning of the boiler and the combined fuel transport auger for feeding of reserve fuel   o The minimum allowed distance between the rear side of the hopper  storage  container   in which the fuel transport auger is
33. on to the heating output of hot  water boiler  3Fera 45      Tanvironment AT Ratio T4 T6 Heating  output     Seconds    Wood    5  Wood Dry Wood E  pellets calibrated pellets calibrated pellets calibrated  wood chips wood chips wood chips          15   85  0 200   0513   30   77             10   30  0 150   0385   23   58                     ose   23   59    24      0  20  0084   0218   13   33   15           15  35  0 253   0660   38   99   45    15 fe    Tooms  average temperature in the heated premises    C   Tenvironment     environment temperature    C   AT  Trooms       environment   temperature load    C        The parameter values defining the boiler   s heating output are determined in  operation with fuel that comply with the requirements  presented in the boiler   s  technical data table  In case the fuel is from another type  size or water content   then these parameters have to be changed  by observing the adjustment  requirements presented above  At the same time other parameters may need  adjustment     for example the values of parameters T4  C1 and T7              6 7  STOPPING THE BOILER OPERATION     The boiler operation can be stopped by the switch    START     In presence of glowing embers the  boiler operation can be restored by switching on the same switch  In case there are no more  glowing embers in the fuel chamber  that can ignite the new loaded fuel  then it is necessary to fire  the boiler manually     3Fera 25 35 45 38          In case the boiler
34. ording to the European  standard for solid bio fuels EN 14961 1 2010  Annex 2  P16  M10    0 7 or A1 5   BD200    The standard equipment of combined hot water wood gasification boiler from series  3Fera   includes      Hot water wood gasification boiler from series  3Fera    1 unit    Directing fireclay made component for the combustion chamber   1 pc   Thermo regulation valve for the firing air flow rate     1 pc    Steel made cleaning brush     1 pc    Steel made cleaning scraper     1 pc    User manual book for installation and operation of wood gasification hot water boiler   utilizing firewood  wood pellets and dry calibrated wood chips                25                 35   and  3Fera 45      1 pc     The appliance consists of    Steel made heat exchanging unit for heating of the heat carrier    Flue gas extraction fan  for extracting the flue gasses out of the boiler    Refueling chamber    Fireclay combustion chamber    Convective heat exchanging module  tube bundle   in which the firing air is  preheated      Control board for monitoring and controlling of the appliance     3Fera 25 35 45 5    Mineral wool heat isolation     The appliance is equipped with     Thermo manometer  temperature pressure gauge  for monitoring the operation  parameters of the circulations water    Thermostat for controlling the flue gas extraction fan operation    Thermostat for indication of the boiler operation mode and the necessity for cleaning      it is offered optionally    Emergency 
35. particles  used for initial firing   should be around 5kg  The nozzle should be monitored in order to prevent its blocking  which may  disrupt the wood gas flow through it  after firing of the wood material     6 3 4  BOILER SWITCH ON           Before switching on the boiler it is necessary to check if the fireclay component  is positioned correctly in the boiler s combustion chamber  centered and backed    to the rear wall         The combined wood gasification boilers from series  3Fera  operate in two different modes      Operation with firewood     Combined operation mode     The desired operation mode of the boiler can be chosen with the mode switch     firewood mode    combined mode from the boiler s interface control panel     In  firewood  mode the process starts by manual firing of the wood logs and by pressing the  switch  Start  in position    Firewood        In    Combine    mode the process starts by manual firing of the wood logs and by pressing the  switch    Start    in    Firewood    position  After the green indication lamp lights  that registers a burning  process  the mode switcher has to be switched to    Combine    mode  After complete burning of the  wood logs the system automatically switches to reserve fuel operation  If after that it is necessary  to operate with wood logs again  the mode switcher must be positioned in    Firewood    mode  After  good inflammation of the wood logs the mode switcher can be positioned in    Combine    mode  again  and 
36. pliance it is recommended to adjust it  according to the heat consumption which will be covered  The heating output which is necessary  for providing constant heat comfort in the premises can be considered as lineal function from the  temperature load AT  the difference between the average rooms  temperatures and the  environment temperature   Therefore a periodical adjustment of the appliance operation  parameters should be performed in case of necessity     The formulation of the below presented data is based on average rooms  temperature of the  heated premises T ooms  20   C  The T4 parameter value is determined in condition that the value  of parameter T6 is constant     Table 6 2  Adjustment of the parameters T4 and T6 in relation to the heating output of hot  water boiler  3Fera 25      Tenvironment AT Ratio T4 T6 T4 Heating  output          Sens   Seconds      Wood Dry Wood Dry Wood Dry  C C pellets calibrated pellets calibrated pellets calibrated  wood chips wood chips wood chips    25      is  o 2  005   ore   os   20         3Fera 25 35 45 37    Table 6 3  Adjustment of the parameters T4 and T6 in relation to the heating output of hot  water boiler  3Fera 35        Tanvironient AT Ratio T4 T6 Heating  output                           MEL Dry Wood Dry  pellets calibrated pellets calibrated pellets calibrated  wood chips wood     wood chips    8 je HI                     0  20  0062   0159   09   24   n      Table 6 4  Adjustment of the parameters T4 and T6 in relati
37. quality of the used fuel directly influences the ash  residues quantity and respectively the necessity for cleaning     3Fera 25 35 45 39             Before cleaning the appliance must be shut down and cooled to room temperature for prevention  of skin burns  The ash must not contain glowing coals  which can cause fire  Before complete  cleaning of the appliance it is recommended to switch off its power supply     The cleaning of the boiler  from the accumulated ash resulting from the wood utilization  has to be  performed periodically  which ensures its high efficiency and reliability     The cleaning of the combustion chamber and the fire grate is mandatory before every firing and  refueling and or on several days  depending on the utilized fuel quantity and the boiler operation  mode        The tools for cleaning the ash residues from the boiler are presented on Figure 6 6     Figure 6 6  Tools  scraper and brush  for cleaning the ash residues from the boiler                 Cleaning of the heat exchanger tube bundle is recommended on a 1 month period  by rendering in  account the boiler operation mode and the utilized fuel quantity  Figure 6 7   The practice shows  that significant part  around 30 40   from the mineral mass  ash  is carried away by the flue  gasses     this leads to fine particles depositing on the boiler   s tube bundle  and also on the flue  gas extraction fan   s operation wheel  At first sight this quantity looks relatively little  but for longer  per
38. quids  according to standard BDS  15207 81  During the heating season it is necessary to keep constant water quantity in the  heating system  Refilling with water should be performed carefully in order to prevent access of air  to the system  The circulations water must be used only for its designation  It is not allowed to  drain the water out of the boiler or the system  except in case of repairs     In case the heating installation is designed with closed expansion tank  then the following should  be taken into account  the heating systems with closed expansion tank are systems operating  under pressure and do not allow direct contact between the circulations water and the surrounding  atmosphere  Therefore such systems are not endangered by intake of air from the atmosphere   Such systems are under pressure and it must be controlled  so they can function without failures      not only the exceeded pressure is dangerous  because the mechanical components loads  increase  and the possibility for defects increases   but also the pressure decrease could lead to  the system improper functioning     even to absorb air from the environment  Therefore it is  necessary to keep constant pressure of the water in the heating system  The circulations water  must be used only for its designation  It is not allowed to drain the water out of the boiler or the  System  except in case of repairs     It is recommended to check the water pressure      the heating system on every 14 days     
39. ra 25    3Fera 35    3Fera 45       Pellets    Chips    Pellets    Chips    Pellets    Chips       T4    impuls in RUN  Period of time for fuel feeding  in operation mode   sec      2 1    5 5    3    7 7    3 8    9 9       T6    Pause in RUN   Period of time for fuel feeding  pause in operation mode    sec      15    15    15    15    15    15       A1    Flame OK   Registered flame    This parameter could be locked   protected     1 3    1 3    1 3    1 3       A2    NO good flame  Unstable flame    This parameter could be  locked     0 9    0 9    0 9    0 9    0 9    0 9       C1    Number of cycles before  cleaning   Number of cycles before  afterburning pause     self   cleaning    100    250    100    250    100    250       T2    Ignition pellet impuls  Impulse fuel for ignition   sec         T3    Ignition pellet pause  Pause fuel for ignition   sec      20    20    20    20    20    20       T7    Limitation in pilot flame  Time limiting for feeding in  smoldering mode   sec      05   0 7    0 7    0 7       TA    No feeed for cleaning  Holds fuel feeding during self   cleaning   sec      200    200    200    200    200    200       TC    Delay flame OK  Time delay when a flame is  registered   sec      60    60    60    60    60    60          TD       NO good flame  Time delay when there is no  flame   sec         30       30       30       30       30       30       The values of the presented parameters    4 and T6 are most frequently changed     they  determin
40. roduct life cycle  its extermination has to be performed in protective for the    environment way  Its modules must be disassembled and transferred to second raw material  redemption stations  by observing the principles for separate collection of wastes     3Fera 25 35 45 42    7  FAILURES AND TROUBLESHOOTING     Table 7 1  Description of the possible boiler operation failures and their troubleshooting        No Failure    Reason    Troubleshooting       1    Low temperature in the  heated premises    Insufficient heating output    It is necessary to decrease the  time between two refuels or and  to increase the firweood quantity       Heating output adjustment of the  boiler is required       Check the fuel moisture and if  necessary replace it with drier       Low temperature assigned  to the operating  thermostat of the boiler    It is necessary to increase the  operating thermostat assigned  temperature value  the maximum  recommended is up to 90  C        Low temperature assigned  to the room thermostat  if  connected     It is necessary to increase the  room thermostat assigned  temperature value       2    High temperature      the  heated premises    High temperature  assigned to the operating  thermostat of the boiler    It is necessary to decrease the  operating thermostat assigned  temperature value  the minimum  recommended is down to 60  C        High temperature  assigned to the room  thermostat  if connected     It is necessary to decrease the  room thermostat
41. rved     Unpredicted risks     The appliance is designed and manufactured in compliance with the acting safety standards   Although all possible risks  resulting by its improper usage  are preliminary considered  it is  possible that the following situations may occur       Risks of burning  caused by the high temperature from the burning process in the  combustion chamber and or access in its chamber door  while cleaning the burning  zone or unburned material  while stirring up the fuel in the fuel chamber  while  servicing handling of the boiler and contact with heated surfaces       Risks of electrical shock from indirect contact  The boiler is connected to the electrical  network and the control modules are positioned in the control board  equipped with the  necessary safety devices  protecting against overload and short circuit  The appliance  ground connection is mandatory and must be performed by an authorized technician      Risks of finger injuring during works of opening  closing and cleaning  It is  recommended to use proper personal safety equipment      Risk of strangulation in case of insufficient chimney draught  clogging of the  convection line of the boiler or improper sealing of the flue pipeline  Also fine ash dust   which teases the respiratory tract of the cleaning person  could be absorbed while  cleaning the ash residues     it is recommended to use protection mask     6 12  ACTIVITIES AFTER THE APPLIANCE LIFE CYCLE PERIOD EXPIRY   After expiry of the p
42. s  box also serves for preheating of the firing air  before it is led to the burning zone  The  inlet section of the box is equipped with a flap which is controlled by thermo   regulation valve  TRV   The TRV is linked to it by a chain and its function is to  partially close the air inlet section when the circulations water temperature increases   The water inlet muff is threaded inside  see Table 3 2 for its size  and is positioned on  the boiler   s low left back side  The water outlet muff is threaded inside  see Table 3 2  for its size  and is positioned on the left top back side of the boiler  By these muffs the  boiler connects to the heating system    The draining muff is with inside threading  see Table 3 2 for its size   It must be  equipped with draining cock    Emergency unloading boiler tube  serpentine  which serves for cooling of the  circulations water in the boiler body  when the temperature exceeds the highest limits   This boiler tube is with outside thread G3 4       Flue outlet  with external diameter   150 mm  positioned in the top back side of the  boiler  after the convection pipeline of the boiler and is used for cooling of the flue  gasses and preheating of the firing air    Steel made heat exchanger and its cover  which are isolated with mineral wool  that  serves for limiting of the heat losses transfer to the surrounding environment    Fuel chamber and combustion chamber cast iron doors  which provide excellent  isolation and sealing of the boiler 
43. s opening  by using scraper  tool or another suitable tool to clean the nozzle opening      Close the fuel chamber door and the ignition air flap     Observe the following rules when adding fuel in the fuel chamber      The refueling should be performed with preliminary prepared fuel  so it happens quickly      in order to prevent flue gas extraction to the boiler room  when the door is opened      Place the fuel longitudinal  parallel  to the chamber s nozzle  by preventing its orifice from  blocking by wood pieces      The door must be fully closed after refueling  Do not allow its blocking by wood pieces       n case the chamber is loaded with mixed wood type   the larger and wetter pieces have to  be positioned in the middle of the chamber  and the smaller and drier particles logs have to  be placed on its periphery  Such arrangement prevents the forming of the so called  overhanging of the fuel over the nozzle        When the circulations water temperature in the boiler is heated up to the assigned  operation temperature  defined by the boiler s operation thermostat  the flue gas  extraction fan switches off and the boiler transits to stand by mode  by which the   fuel is not consumed so intensively  One part of the fuel is still consumed in order to  keep the wood glowing  During stand by mode the heating output is around 1096 from  the boiler nominal output              6 6 2  BOILER OPERATION IN COMBINED MODE     For optimal  reliable and efficient operation of the ap
44. series  3 Fera  to a heating installation together  with heat accumulator and water mixing valve  as presented on Figure 5 6     3Fera 25 35 45 21       Figure 5 6  Recommended hydraulic diagram for connecting hot water boiler from series    3 Fera     to heating installation  heat accumulation tank and water mixing valve        24 23 3 4    lll VAS             F 7  p oan vata retis  Domestic hot    X            water Y    ra  I                 1  uer        15    4 5 6 2222 7 16 9 10                   r         10    Va 13 Mi    g             y    p55 aM    From heating  system          Tap water          Table 5 2  Identification of the components marked on Figure 5 6                                                                       No  Identification No  Identification  1 Hot water boiler from series 11 Ball valve     3Fera    12 Water filter  2 Safety valve 13 Temperature valve TV  3 Boiler hot domestic water 14 Retaining valve  4 Retaining valve 15 Contact thermostat  5 Circulations pump 1 16 Heat accumulator  6 Safety valve 17 Automatic water refilling device  7 Opened or closed expansion 18 Filling and draining cock  tank 22 Air free device with flap  8 Ball valve 23 Safety valve  9 Three way mixing valve 24 Retaining flap  10 Circulations pump 2          3Fera 25 35 45    22    6  INITIALIZATION OF THE APPLIANCE IN OPERATION           The combined wood gasification hot water boilers from series  3Fera  must be  initiated in operation only by specialized company  a
45. so on     this is cycle process and is limited only by the necessity for cleaning  If  necessary the boiler can operate only with one fuel type     If the appliance has been adjusted to    Combine    mode  but the electrical supply was interrupted   the system continues with complete burning of the remaining fuel and after that it automatically  switches to reserve fuel     When the boilers thermostat assigned temperature has been reached or when the room  thermostat switches off  afterburning  smoldering  follows  In operation with reserve fuel the boiler  keeps smoldering mode  by periodical fuel feeding  which keeps it glowing  After the water  temperature drops or the system receive operation signal by the room thermostat  it follows with  inflammation and operation in normal mode     3Fera 25 35 45 28          If there is no glowing fuel in the boiler   s fuel chamber it is necessary to perform initial  manual firing of the fuel  For the purpose small quantity of wood should be loaded  and fired              During the boiler initial start up the reserve fuel transport auger  wood pellets or  dry calibrated wood chips  must be filled with fuel  Such filling is continues process  and continues until the fuel starts to drop in the boiler   s fuel chamber  The boiler  must be started after the feeding auger has been filled with reserve fuel     this is a  mandatory primary condition for operation in combine mode              It is not recommended to operate the appliance wi
46. spected and its condition evaluated     it is recommended to be  performed by specialist  After inspection and insurance that the boiler condition is operational and  there are no damages on its construction  which might lead to dangerous situations  it can be  restored to operation again  It is recommended to approach its restoring in operation carefully   slow heating   by monitoring and inspecting its body for leaks or other unusual events           The burning process in the fuel chamber must not be stopped by forced  extinguishing  without water or other extinguishing liquids   because it may lead to   irreversible damages to the heat exchanger or to the firing nozzle  It is  recommended to cool the appliance down to safe temperatures and after that to  make inspection and evaluation of its condition        6 8  BOILER SHUT DOWN     The boiler shutting down is a step by step process  First the fuel feeding must be stopped  After  complete burning of the fuel and the glowing coals  and after the boiler cools down  it must be  shut down by pressing the switch POWER  which is positioned on the rear interface panel with  managing connectors  It is also recommended to clean the appliance from the ash deposits              It is forbidden to shut down the boiler by the key POWER during operation        6 9  BOILER CLEANING   For maintaining highly efficient and reliable operation it is necessary to clean the boiler from the    ash deposits  Not only the quantity  but also the 
47. st be noted  in its warranty card  It is mandatory to fill all fields with the required information                 heating installation and the boiler have to be filled with circulations liquid     in most  cases with fresh water  The water  used for filling the boiler and the heating installation  must be transparent  without color  without deposits  oils and aggressive chemical  impurities  The hardness of the water must comply with the tolerable norms  presented in  the next table  In case the used water parameters do not correspond to those presented in  the table  then water with suitable characteristics should be used or chemical treatment  must be performed     Table 5 1 represents the heating system water parameters  which must comply with the  requirements of standard BDS 15207 81     Table 5 1  Parameters of suitable water for the heating installation                                   Parameter Dimension Value  Overall hardness mg eq kg 30  Oxygen content mg kg 100  Oil and heavy oil products mg kg 3  Overall hardness mg kg 50  Salts content mg kg 6000  Total alkalinity mg kg 30  pH   8 0   9 5  Content of free CO  mg kg Not allowed                In case the boiler is connected to heating installations  where the water is in contact with copper   for example copper pipes   the pH  hydrogen exponent  value must not exceed 10     The manufacturing company recommends the following hydraulic diagram for connecting a    combined wood gasification hot water boiler from 
48. th its doors opened     on the fuel  and combustion chambers  It is not recommended to operate the appliance with an  auger that is power supplied by external from the boiler s plug  The auger power  supply from external plug is allowed only during its initial filling with fuel  as the  boiler must be switched off until the auger has been filled  i e  do not allow  uncontrolled combustion        For initial start of the appliance the upper chamber must be filled with initial fuel quantity     detailed  description is presented in the manual  After that the initial quantity has to be fired manually and  after stabilization of the burning process the following activities have to be performed  in  dependence on the used fuel      Firewood   fill the fuel chamber completely and switch to automatic mode      Switch to automatic fuel feeding mode     wood pellets or dry calibrate wood chips        The fuel transport auger must be filled with fuel  If it does not feed fuel to the boiler s  upper chamber at the first attempt  then restart of the appliance is required              E   E    The boiler operates by preliminary installed algorithm  Its software is password  protected against unauthorized access  For the user  respectively well familiar with  the presented manual book  are allowed only a group of parameters for control and  adjustment          The boiler s water operation thermostat  0     90  C  has to be adjusted on the desired temperature   It is recommended to be withi
49. thermostat for protecting the appliance from overheating    Boiler tube serpentine  for emergency cooling of the boiler in case of exceeding its  operation temperature    Combined fuel feeding auger for dry calibrated wood chips  P20  EN 14961 2   moisture up to 10   and for wood pellets with diameter   6 8 mm  It suits all boiler  models and is offered as an optional equipment     Advantages of the boiler     Availability for usage of reserve fuel  after completion of the firewood burning     wood  pellets or dry calibrated wood chips  which provides INDEPENDENT operation mode   High efficiency  Eff coef    93   during utilization of the three fuel types  which  guarantees exclusively economic operation and low costs for heating    Easy servicing  handling  thanks to its wide door and availability for firing of wood  logs with diameter up to 20 cm  maximum length 50 cm and moisture up to 20    Combustion chamber equipped with high quality ceramics  which guarantees  maximum efficient burning process    Cleaning mechanism for the heat exchanger tube bundle  ensuring stable efficiency   Thanks to the firing air flow rate thermo regulation valve maximum fuel utilization and  economic operation of the boiler are guaranteed    Reliable and safe operation  thanks to its stainless unloading serpentine and  compliance with the requirements of EN303 5 standard    Availability for adjustment of the heating output within wide range    The boiler is factory equipped with flue gas extrac
50. tion fan    Possibility for monitoring of the processes in the combustion chamber through the  doors monitoring glasses    Components by reputable European manufacturers    If a thermostat mixing group Laddomat is added  the life length of the appliance will  be longer and the fuel economy will be higher  up to 2095     The boiler is ecological with low harmful emissions levels     below the strictest  requirements of the European standards           operation temperatures during heating of water from accumulation tank and    G  LADDOMAT is thermostat mixing group  which assists for quicker reaching to    implements the process of temperature stratification        3Fera 25 35 45 6       3  TECHNICAL DATA FOR COMBINED WOOD GASIFICATION HOT WATER  BOILER FROM SERIES    3 Fera        The heating technical data of combined wood gasification hot water boiler from series   3Fera   utilizing firewood  wood pellets and dry calibrated wood chips  are presented in    Table 3 1     Table 3 1  Heating technical data of combined wood gasification hot water boiler from series                 SFera   Parameter Dimension Value  Boiler model   3Fera 25 3Fera 35 3Fera 45  Nominal output kW 25 35 45  Heating output operation kW 9 25 11 35 15   45                           Used fuel    chips    Firewood  wood pellets  dry calibrated wood       Wood pellets categories   according to standard EN  14961 2      ENplus A1  ENplus A2  ENplus B       Wood pellets categories  according to the appliance 
51. ton marked as Menu OK  to confirm the change  or choose    No     to cancel the  change of settings     3Fera 25 35 45 30       8  Press the green button  marked Menu OK on the control board one more time to exit the  parameters menu  The control module display shows normal operation mode RUN        PASSWORD  CLEAR 0 5  0000  5 maxmum    attempts for entering    SHIFT   OK   EXIT the password       It is necessary to exit this mode  The method is presented on the screen   press together the  buttons  SHIFT  and  OK     by pressing  SHIFT  and without releasing it also press the button   OK    Submenu appears which can be exited by pressing the button arrow left   lt 4      Another easier method is by switching off and on the main power supply by using the switch  POWER        Figure 6 5  Information appearing on the control module display after reaching the limit of attempts  for entering the password  respectively transition to the service menu     PASSWORD  CLEAR ERROR  5 5  gt  gt  gt  30 MINUTES       The message on the control module screen means that it is necessary to wait for period of 30  minutes as the appliance remains switched on  After expiry of this period  30 minutes  the above  presented procedure must be performed     it is necessary to press together the buttons  SHIFT     3Fera 25 35 45 31    and  OK     On the control module screen appears a submenu which can be exited by pressing  button arrow left  4   Another method is to wait at least 30 minutes and to
52. urfaces    Low temperature of the  inlet water    Adjustment of the circulations  pump thermostat is required  The  recommended temperature for  operation start of the circulations  pump is minimum 65  C       8  Presence of smoke in  the boiler room after  certain operation  period    Insufficient chimney  draught    It is required to heat the chimney  in order to provide conditions for  reliable operation       The chimney condition has to be  evaluated by expert     whether it  has the needed height  outlet  section area  isolation and  configuration     to be performed  by specialist       The chimney is dirty or  clogged with ash    Clean the chimney        The flue pipeline is dirty or  clogged with ash    Clean the flue pipeline        Inefficient sealing of the  doors by the heat resistant  sealing ropes    Replacement of the sealing ropes  is required     to be performed by  specialist       9    Abnormal heating of  the wood pellets  dry  calibrated wood chips  combined transport  auger    Insufficient chimney  draught or dirty appliance   boiler     Cleaning of the boiler  eventually  the chimney is required  Possible  solution is installation of  additional flue gas extraction fan  and or change of the chimney       10    Heating of the wood  pellets or dry calibrated  wood chips transport  auger and activation of  the emergency    Low chimney draught or  dirty appliance  boiler     Cleaning of the boiler  eventually  the chimney is required  Possible  solution is
53. uthorized to perform such  activities        6 1  GENERAL REQUIREMENTS ABOUT THE USED FUEL        n order to achieve complete burning it is necessary to use only dry fuel  with  characteristics that comply with the fuel requirements  The manufacturing company  recommends storing of the fuel in dry and ventilated premises or under roof  where it will  be protected from moistening      Storing the fuel next to the boiler or at distance less than 500 mm is forbidden      The recommended distance by the manufacturing company is minimum 1000 mm  It is  better to store the fuel in a neighbor premise      The fire safety requirements must be observed during the boiler installation and the fuel  storing  It is recommended to keep fire extinguisher at near and safe place     6 2  GENERAL REQUIEMENTS DURING OPERATION OF THE HEATING INSTALLATION     In case the heating installation is designed with opened expansion tank  then the following should  be taken into account  the heating installations with opened expansion tank provide direct contact  between the heating  circulations  water and the surrounding atmosphere  During the heating  season the water in the expansion tank absorbs oxygen  through their contact surface   which  increases the corrosive action of the circulations liquid over the steel surfaces  and circulations  liquid  water  vaporization could be noticed also  For the system refilling must be used only water  that complies with the usage requirements of circulations li
54. voice and original warranty card are  presented        3Fera 25 35 45 47    
55. volume    Outside decoration covers that are made from steel and are coated with quality color  paint    Combined fuel transport auger  it is offered as additional option  for feeding of the  combined hot water boilers from series  3Fera  with wood pellets or dry calibrated  chips     General view of combined wood gasification hot water boiler from series  3Fera    utilizing  firewood  wood pellets and dry calibrated chips  is presented in Figure 4 1     3Fera 25 35 45 10    Figure 4 1  General view of combined wood gasification hot water boiler from series  3Fera                     Figure 4 2 represents front view of the combined hot water boiler from series                    Rear side view of the boiler from series                  is presented in Figure 4 3     3Fera 25 35 45 11    Figure 4 2  Front view of combined wood gasification hot water boiler from series  3Fera                          Primary air valve 1     Primary air valve 2     Total air valve     Secondary air valve     Ash cleaning cover     Reserve fuel inlet     Emergency cooling boiler tube  input output     NOOR WD      3Fera 25 35 45 12    Cross section view of combined wood gasification hot water boiler from series  3Fera   with  shown flue gas and ash directions  is presented in Figure 4 4     The overall sizes of combined wood gasification hot water boiler from series    3Fera    are  presented on Figure 4 5     Figure 4 4  Cross section view of combined wood gasification hot water boiler from seri
56. y BD kg m  200  Recommended fuel caloricity  net Q MJ kg  gt 16 0  calorific value  net kWh kg 24 4  Dry calibrated wood chips parameters   according to standard EN 14962 1 I LIAMA                       The combined wood gasification hot water boilers from series  3Fera  are not  designated for utilization of every solid fuel type  including coal and cokes        3Fera 25 35 45             4     CONSTRUCTION DESCRIPTION OF COMBINED WOOD GASIFICATION HOT  WATER BOILER FROM SERIES    3 Fera      The combined wood gasification hot water boiler from series  3Fera  consists of the following  main components and modules     Heat exchanger which presents welded steel plate construction  In the upper part of  the boiler is formed the fuel loading chamber  in which the substances volatile from  the wood  In the lower part of the heat exchanger is formed a combustion chamber  in  which the combustion nozzle and the fireclay lining of the combustion chamber are  formed    The fireclay made combustion nozzle  positioned in the refueling chamber lower part   provides conditions for effective substances volatile  the burning gasses  separated  during the fuel gasification  and their burning    Fireclay made directing elements  mounted in the combustion chamber  providing  optimum combustion and assist for complete fuel burning    Flue gasses extraction fan  installed in the back side of the boiler    Air distribution box  which is used for adjusting the primary air flow rate by a flap  Thi
    