chad 50 psi compressor patient instructions

image

Contents

1. AND CLEANING THE FILTER Pull air intake filter out from front of unit and replace with a new one when dirty Do not wash it VAN Caution Do not submerge in water as this will result in damage to the compressor 18450 FILTER Replacement Intake Filter 1 ea SPECIFICATIONS CLASSIFICATIONS Symbols Size L x W x H 15 x 10 5 8 x 18 1 Weight 17 2 lbs Model 18450 Electrical R irement TOAS ri equir nts 6 q A 60Hz Pressure Range 0 50 PSI Flow Rate Range 11 41 LPM Power Consumption W 170 0 PSI Operating Temperature range 50 F 104 F Operating Relative Humidity 95 Maximum Storage amp Transport Temperature Relative Range room condition preferred Circuit Breaker 5A 125 250 VAC Sound Level lt 60 dBA Equipment Classifications With respect to protection from Electrical shock Class Electrical hazard protection class Type B Degree of protection against the ingress of water IPX0 Protection is not provided No AP APG Equipment not suitable for use in the presence ofa flammable anaesthetic mixture with air oxygen or nitrous oxide TROUBLE SHOOTING If the compressor malfunctions refer to the trouble shooting chart below for probable cause and remedy If you can not get the machine to operate call your home care provider TROUBLE SHOOTING CHART TROUBLE PROBABLE CAUSE REMEDY A Unit not operating 1 P
2. ASIC OPERATION PARTS HANDLE POWER RESET restarts unit after overload FIGURE 1 OPERATING INSTRUCTIONS INITIAL POSITIONING AND INSTALLATION 1 Select a suitable location for the unit near a 120 VAC 230VAC grounded power Outlet 2 Grasp handle on top of cabinet and position the unit so that operating controls are Accessible to the user and back of unit is away from wall 3 Make certain that the power switch located in the center of the control panel is in the OFF position and plug power cord into grounded power outlet or grounded adapter 4 Be certain that all connections to outlet i e tubing nebulizers etc are snug and not leaking aerosol 5 When used in conjunction with mist tents etc place unit outside of tent and place unit at a level below discharge end of the delivery tubing OPERATION 1 Press Power On Off switch to ON position 2 To check the pressure that the compressor is delivering occluded outlet or connect equipment you intend to use with the compressor Pressure can be adjusted with regulator and observing pressure gauge as follows a Pull regulator knob out to unlock adjustment b Turn dial of regulator to desired pressure clockwise increase pressure counterclockwise decrease pressure Push knob towards unit locking regulator pressure O ROUTINE MAINTENANCE REMOVING
3. CHAD 50 PSI COMPRESSOR PATIENT INSTRUCTIONS MODEL 18450 CONTENTS Page No GENERAL INFORMATION wicitssnsietietancusineeninntacgatcielghannasaiiweataors 1 Safety Precautions imore a RR ce acta ada cease eaten eae ded dace ace 2 Basi OperaunG Panss lt cccaseuzsc erase TRET C enaA RAEN AS TENAR 3 OPERATING INSTRUCTIONS x x x x x e e 4 Initial Positioning and Installation ce c cee x e x eee eee eee eee eee eee 4 Operation ese e a ad aint thee lade eiatee te E aes 4 ROUTINE MAINTENANCE 5 Removing and Cleaning the Air Intake Filter x x K K K Kee 5 SPECIFICATIONS Sernin pete ein adltticnme diced ates soci Vaasa AAE RE 6 TROUBLE SHOOTING titi diamond e AAE 7 Trouble Shooting Chart ag ar cd e Noe Ea e 7 WARRANTY aoan oen a a a a a E E S EA 8 GENERAL INFORMATION This manual provides information necessary to operate the 50 PSI Compressor This unit is designed for the most efficient continuous high pressure performance The compressor provides the high pressure which clinical studies have indicated are required for optimal particle size 2 microns or less It operates quietly and effectively due to the unique design of the WOB L piston Easy to clean very low maintenance compact light weight and portable Powered by standard home current makes it s operation easy and practical for home and hospital use wi
4. d Port Washington NY 11050 Phone 516 998 4600 Fax 516 998 4601 www drivemedical com
5. lug not firmly in wall 2 No power at wall outlet 1 Check plug at outlet 2 Check power source fuse in house B Limited air flow 1 Faulty Delivery Tubing 2 Leak 3 Blocked intake filte 1 Disconnect delivery tubing at outlet If proper flow is restored check equipment and tubing for obstructions or kinks Replace if needed 2 Check fitting at outlet and tubing 3 Clean air intake filter If flow is not restored call your home care provider C All other problems 1 Call your home care provider 1 YEAR LIMITED WARRANTY Your Drive brand product is warranted to be free of defects in materials and workmanship for one 1 year of the original consumer purchaser This device was built to exacting standards and carefully inspected prior to shipment This 1 Year Limited Warranty is an expression of our confidence in the materials and workmanship of our products and our assurance to the consumer of years of dependable service This warranty does not cover device failure due to owner misuse or negligence or normal wear and tear The warranty does not extend to non durable components such as rubber accessories casters and grips which are subject to normal wear and need periodic replacement If you have a question about your Drive device or this warranty please contact an authorized Drive dealer Oe drive Drive Medical Design amp Manufacturing 99 Seaview Boulevar
6. th most makes of aerosol generators such as Compatible with hand held nebulizer system Heated nebulizer Dual action humidifier nebulizer Pediatric mist tent High output pneumatic nebulizer Deluxe nebulizer with oxygen diluter Child adult mist tent SAFETY PRECAUTIONS When using electrical products especially when children are present basic safety precautions should always be followed Read all instructions before using Important information is highlighted by these terms A DANGER Urgent safety information for hazards that will cause serious injury or death N WARNING Important safety information for hazards that might cause serious injury N CAUTION Information for preventing damage to the product NOTE Information to which you should pay special attention READ ALL USER S MANUAL BEFORE USING SAVE USER S MANUAL AN Note Connect power cord and plug to properly grounded wall outlet or adapter AN Note Unplug the power cord when it is necessary to disconnect AC power source AN Note The compressor is not designed to drive ventilators AN Note Follow the national requirement to dispose unit AN Caution Ingestion of aerosols into the compressor may result in damage to the unit and void the warranty PRESSURE GAUGE Indicates pressure REGULATOR determines Pressure output INTAKE FILTER ON OFF SWITCH starts and stops unit On position Ly Off position B