1. PC Board Terminal Type Solder Terminal Type All dimensions in mm der 13 022mm XW series Emergency Stop Switches Dimensions Illuminated e Screw Terminal IP20 LED Illuminated Type 040mm Operator LED Push ON Type 185 20 1 Gasket Locking Ring IP20 Protection Cover XW9Z VL2MF e Screw Terminal w terminal cover LED Illuminated Type 40mm Operator LED Push ON Type Terminal Cover XW9Z VL2M e Solder Terminal and PC Board Terminal LED Illuminated Types 40mm Operator Panel Thickness 0 8 to 6 T PC Board Layout Bottom View PC Board Terminal Type Solder Terminal Type All dimensions in mm 14 022mm XW series Emergency Stop Switches Mounting Hole Layout 622 32 Terminal Arrangement Bottom View e Screw Terminal Non illuminated Type NC main contacts only NG main contacts Terminals 1 2 With 2NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 With 1NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 1NC Terminals on right 2NC Terminals on right and left 3NC Terminals on right left and top 1NC Terminals on top 2NC Terminals on right and left e Screw Terminal Illuminated Type With 2NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Te
2. NC main contacts Terminals 1 2 NC main contacts Terminals 1 2 ee eee a NO monitor contacts Terminals 3 4 Y HA e The values shown above are the PEE CES N minimum dimensions for mounting 3 with other 616 mm pushbuttons For Left other control units of different sizes and styles determine the values according to the dimensions opera tion and wiring convenience Right Left 1NC Terminals on right 1NC Terminals on top 2NC Terminals on right and left 2NC Terminals on right and left 3NC Terminals on right left and top O il 016mm XA series Emergency Stop Switches Accessories PAY Ordering Package Ring Wrench e Used to tighten the locking ring when installing the XA emergency stop switch onto a panel Metal MT 001 MT 001 1 e The recommended tightening nickel plated brass torque is 0 88 N m at maximum Locking Ring e Black Plastic HA9Z LN HA9Z LNPN10 10 Terminal Cover e White e Used for solder terminals e Also applicable to the XW series PBT XA9Z VL2 XA9Z VL2PN02 2 Nameplates TypeNo Material PlateColor Legend Color blank HAAV 0 For 29mm Operator EMERGENCY STOP HAAV 27 Polyamide Yellow Black blank HAAV4 0 For 40mm Operator EMERGENCY STOP HAAV4 27 e For 029mm Operator e For 040mm Operator e Panel thickness when using the nameplate 0 5 to 2 mm 17 0 5 e Panel thickness when using the nameplate 0 5 to 2 mm All dimensions in mm d
3. a Worlc S XW Series Mala SNOKESt The depth behind the panel Solder terminal 37 1 mm Screw terminal 48 7 mm Up to 4 contacts save space Conventional Emergency Stop S Space Saving r As of June 2004 Screw Terminal Solder Terminal PC Board Terminal Two button colors Bright Red Dark Red Munsell 7 5R4 5 14 Munsell 5R4 12 016mm XA series Emergency Stop Switches The World s First 816 mm 4 contact Emergency Stop Switch Compact size only 27 9 mm deep behind the panel eLead free RoHS compliant e The depth behind the panel is only 27 9 mm for 1 to 4 con tacts e IDEC s original Safe break action ensures that the con tacts open when the contact block is detached from the operator e1 to 4NC main contacts and 1NO monitor contact e Push to lock Pull or Turn to reset operator e Direct opening action mechanism IEC60947 5 5 5 2 IEC60947 5 1 Annex K e Safety lock mechanism IEC60947 5 5 6 2 e Degree of protection IP65 IEC60529 e Two operator sizes 629 and 040 mm e Dark red Munsell 5R4 12 or bright red Munsell 7 5 R4 5 14 colors are available for the operator of emergency stop switches and gray for stop switch operators e UL c UL approved EN compliant UL508 CSA C22 2 No 14 Approval Organization File No UL c UL File No E68961 TUV Product Service EN60947 5 1 EN60947 5 5 Note Self declaration European Commission s Low Voltage Directive
4. o16mm XA series 022mm XW series Emergency Stop Switches a http safety idec com Oo 000000 0 0 OG 060000 Do 9 060 000 O IDEC IZUMI CORPORATION New Global Standard for Safety 016mm XA and 922mm XW Series Emergency Stop Switches Gare Break Actii 022 XW Series 016 XA Series Push to Lock Pull mmo Reset Compact Size L R W Safety Products When the contact block is detached from the operator the cam directly opens the NC main contacts contacts are off Detaching the Contact Block Operator Contact Block Safety Features Conventional Emergency Stop Switches XA XW Series Emergency Stop Switches NEW Normal Status Latched Normal Status Latched L 1 NC contacts NC contacts ON machine ON machine can operate can operate With the XA and XW emergency stop switches the energy level of the on closed NC contacts is higher than that of the off open contacts If the ie bee falls off due to excessive shocks the NC contacts are always inclined to turn off thus ensuring safety by stopping the machine Direct Opening Action IEC60947 5 5 5 2 IEC60947 5 1 Annex K gt Safety Lock Mechanism IEC60947 5 5 6 2 Push to lock Pull Turn to unlatch The XA and XW emergency stop switches can be unlatched by either pulling or turning the operator XA Series The depth behind the panel is 27 9 mm Up to 4 contacts are available
5. NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 TOP Right Left Right Left 1NC Terminals on right 2NC Terminals on right and left 3NC Terminals on right left and top 1NC Terminals on top 2NC Terminals on right and left Solder Terminal Type only Notes With 1NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 NC main contacts only NC main contacts Terminals 1 2 e For screw terminal types the back label of contact block shows the terminal numbers of contacts in two digits The number in ten digits show the contact number while the number in the units place show the contact codes NC main contact 1 2 NO monitor contact 3 4 e For solder terminal and PC board terminal types the contact block is marked with contact codes NC main contact 1 2 black NO monitor contact 3 4 blue 15 022mm XW series Emergency Stop Switches Accessories re Package Ring Wrench Metal nickel plated brass MWOZ T1 MWOZ T1 weight approx 150 g Anti rotation Ring TI Plastic HW9Z RL HW9Z RLPN10 Locking Ring Plastic HW9Z LN HW9Z LNPN05 Terminal Cover Terminal Cover PBT XA9Z VL2 XA9Z VL2PN02 XW9Z VL2M XW9Z VL2MPN02 Polyamide XW9Z VL2MF XW9Z VL2MFPN02 Note e XW emergency stop switches of screw terminal type are provided with a terminal cover e All dimensions in mm IP20 Protection Cover e Used to tighten the locking
6. Note Except for stop switches operator color gray Contact Ratings NC main contacts NO monitor contact Rated Operating Voltage Ue 30V AC 12 AS UE npa Inductive Load Main AC 15 1 5A 1 5A 0 4A 0 2A 0 1A 1 2A 0 6A 0 6A Rated Operating Current AC 12 A H GAAN Inductive Load AC 14 Resistive Load oe Inductive Load e Minimum applicable load 5V AC DC 1 mA reference value Operating area may vary according to the operating conditions and load types e The rated operating currents are measured at resistive inductive load types specified in JIS C8201 5 1 Contacts Resistive Load 2A DC 12 DE Inductive Load 1A DC 13 l om om gt Direct Opening Action Specifications IEC60947 5 1 EN60947 5 1 IEC60947 5 5 Note EN60947 5 5 Note JIS C8201 5 1 UL508 CSA C22 2 No 14 Operating Temperature 25 to 60 C no freezing Operating Humidity 45 to 85 RH no condensation 45 to 80 C Push to lock 10 5N Pull to reset 10N Turn to reset 0 16 N m Required for Direct 60N Opening Action Minimum Operator Stroke Required for 4 0 mm Direct Opening Action 50 mg maximum initial value 100 MQ minimum 500V DC megger 2 5 kV 900 operations hour Operating extremes 150 m s Damage limits 1000 m s Operating extremes 10 to 500 Hz amplitude 0 35 mm acceleration 50 m s 10 to 500 Hz amplitude 0 35 mm acceleration 50 m s 250 000 operations minimum 100 000
7. mm maximum 2 Solder the terminals using a 20W soldering iron within 5 sec onds or at 260 C within 3 seconds Do not apply external force Make sure that the soldering iron touches the termi nals only When wiring do not apply tensile force on the ter minals 3 Use a non corrosive rosin flux Because the terminal spacing is narrow use protective tubes or heat shrinkable tubes to avoid burning of wire coating or short circuit e PC Board Terminal Type When mounting a contact block on a PC board provide suffi cient rotating space for the PC board when installing and removing the contact block 2 When mounting an XW emergency stop switch on a PC board make sure that the operator is securely installed e About PC Board and Circuit Design 1 Use PC boards made of glass epoxy copper clad laminated sheets of 1 6 mm in thickness with double sided through hole PC boards and circuits must withstand rated voltage and cur rent including the instantaneous current and voltage at switching The minimum applicable load is 5V AC DC 1 mA This value may vary according to the operating environment and load 4 Within the 2 8 mm areas shown in the figure below termi nals touch the PC board resulting in possible short circuit on the printed circuit When designing a PC board pattern take this possibility into consideration 19 8 e NO oo 19 8 Surface for installing components Sold
8. on the contact block Press the con tact block onto the operator and turn the contact block clock wise until the bayonet ring clicks TOP marking Press TOP marking contact block e Notes for Installing the Contact Block Check that the contact block is securely installed on the operator When the emergency stop switch is properly assembled the bayonet ring is in place as shown below Co Ul 016mm XA series Emergency Stop Switches Operating Instructions Wiring 1 The applicable wire size is 1 25 mm maximum 2 Solder the terminals using a 20W soldering iron within 5 seconds or at 260 C within 3 seconds Do not apply external force Make sure that the soldering iron touches the terminals only When wiring do not apply tensile force on the terminals 3 Use a non corrosive rosin flux 4 Because the terminal spacing is narrow use protective tubes or heat shrinkable tubes to avoid burning of wire coating or short circuit e PC Board Terminal Type 1 When mounting a contact block on a PC board provide sufficient rotating space for the PC board when installing and removing the contact block 2 When mounting an XA emergency stop switch on a PC board make sure that the operator is securely installed e About PC Board and Circuit Design 1 Use PC boards made of glass epoxy copper clad lami nated sheets of 1 6 mm in thickness with double sided through hole PC boards and circuits mus
9. operations minimum 250 000 operations minimum 24V AC DC 100 mA Degree of Protection P65 IEC60529 Short circuit Protection 250V 10A fuse Type aM IEC60269 1 IEC60269 2 Conditional 1000A Short circuit Current Solder terminal PC Board terminal 0 88 N m 1 25 mm maximum AWG16 maximum 20W 5 seconds maximum or 260 C 3 seconds maximum 029 mm type 23 g 640 mm type 28g Note Except for stop switches operator color gray Applicable Standards Storage Temperature Operating Force Minimum Force Contact Resistance Insulation Resistance S O 55 D Overvoltage Category Impulse Withstand Pollution Degree Operation Frequency Shock Resistance Voltage Vibration Resistance scouts Damage limits Mechanical Life Electrical Life Terminal Style Recommended Tightening Torque for Locking Ring Connectable Cable Soldering Conditions D G 016mm XA series Emergency Stop Switches Types Solder Terminal PC Board Terminal Types men ee oor God Contact Contact Color Code 729mm Operator anc JJ XATEBvsote XATE BvS0TVe anc XE XAT Bva0eve anc xr Buso Kaba ane XE kabs m OC 3 KATEBVS1OV R Dark red 240mm Operator Ne xArE Bvaote XMIEBV40IV RH Bright rea Ne xaea Kaba Ne xaea Kabo ane xE Kabo RIE e Specify a color code in place of in the Type No e Term
10. Cable Soldering Conditions Recommended Tightening Torque for 0 6 to 1 0 N m Terminal Screw 040 mm type 729 a60 mm type 81 9 D Ce O ae il 022mm XW series Emergency Stop Switches Non illuminated Screw Terminal Types Contact Contact 1P20 wTerminalGover Color Code 240mm Operator 5 Ed R Dark red 060mm Operator RH Bright red QOO 2NO e Specify a color code in place of in the Type No e P20 types can be connected to solid wires only Non illuminated Solder Terminal PC Board Terminal Types NC Main NO Monitor Operator Contact Contact Color Code 040mm Operator A R Dark red RH Bright red A O CEO e Specify a color code in place of in the Type No e Terminal cover XA9Z VL2 is ordered separately der 1 022mm XW series Emergency Stop Switches LED Illuminated Screw Terminal Types Illumination Rated NC Main Type No Appearance Naa 240mm Illuminated Operator ANG XW1E LV401Q4MFR XW1E LV401Q4MR 2NG XW1E LV402Q4MFR XW1E LV402Q4MR 3NG XWIE LV403Q4MFR XW1E LV403Q4MR 24V ANC XW1E LV404Q4MFR XW1E LV404Q4MR AC DC XW1E LV411Q4MFR XW1E LV411Q4MR XW1E LV412Q4MFR XW1E LV412Q4MR 3NC INO XW1E LV413Q4MFR XW1E LV413Q4MR DOCES E ino ust XW1E LV422Q4MFR XW1E LV422Q4MR e The operator color is red only e P20 types can be connected to solid wires only LED Illuminated Solder Terminal PC Board Terminal Types N
11. D 2 3 Macro Court Rowville Victoria 3178 Australia Toll Free 1 800 68 4332 Fax 61 3 9763 3255 E mail sales au idec com www idec com IDEC IZUMI ASIA PTE LTD No 31 Tannery Lane 05 01 Dragon Land Building Singapore 347788 Tel 65 6746 1155 Fax 65 6844 5995 E mail generalinfo idecasia com sg IDEC IZUMI H K CO LTD Room 1409 Tower 1 Silvercord 30 Canton Road Tsimshatsui Kowloon Hong Kong Tel 852 2 376 2823 Fax 852 2 376 0790 E mail idec idechk com IDEC IZUMI Shanghai Co Ltd Room E 15F Majesty Building No 138 Pudong Avenue Shanghai 200120 P R C Tel 86 21 5887 9181 Fax 86 21 5887 8930 E mail idec cn idec com IDEC TAIWAN CORPORATION 8F No 79 Hsin Tai Wu Road Sec 1 Hsi Chih Taipei County Taiwan Tel 886 2 2698 3929 Fax 886 2 2698 3931 E mail service idectwn com tw Cat No EP1050 0 AUGUST 2004 PRINTED IN JAPAN
12. O Type No Monitor Terminal Style terminal style Contact 240mm Muminated Operator NG wenoo XWIELVADIGAVA ane xwiewvaoeasR XWiELVARGEVA rf Ng Dano xwiewv4osasR XWIELVADSGAVA Illumination Rated NC Main Appearance Type Voltage Contact zy ano wievansaar XWELVADAAVR ACIDO e ino xWie Wvaisaan KWE vaio m CES ano ano wewegan e The operator color is red only e Terminal cover XA9Z VL2 is ordered separately Push ON LED Illuminated Screw Terminal Types Illumination Rated NC Main Type No Appearance ones 0g Contact IP20 w Terminal Cover 040mm Illuminated Operator 3NC XW1E TV403Q4MFR XW1E TV403Q4MR Hi 24V AC DC 2NC 1NO XW1E TV412Q4MFR XW1E TV412Q4MR Ws O OCES e The operator color is red only e Push ON types is illuminated when the operator is latched and turns off when reset e IP20 types can be connected to solid wires only 12 022mm XW series Emergency Stop Switches Dimensions Non Illuminated e Screw Terminal Type IP20 Panel Thickness 0 8 to 6 XW9Z VL2MF 040mm Operator lt 060mm Operator e Screw Terminal Type w terminal cover Gasket Locking Ring Terminal Cover XW9Z VL2M 040mm Operator e Solder Terminal and PC Board Terminal Types 040mm Operator Panel Thickness 0 8 to 6 PC Board Layout Bottom View Terminal Cover XA9Z VL2
13. ck 32N Pull to reset 21N Turn to reset 0 27 N m Applicable Standards Operating Temperature Operating Humidity Storage Temperature Operating Force Minimum Force Required for Direct Opening Action Minimum Operator Stroke Required for Direct Opening Action Maximum Operator Contact Resistance 50 mQ maximum initial value nsulation Resistance 100 MQ minimum 500V DC megger Overvaltage Category i SSS S Impulse Withstand deg O D N OT x lt 900 operations hour Operating extremes 150 m s Damage limits 1000 m s Operating extremes 10 to 500 Hz amplitude 0 35 mm acceleration 50 m s 10 to 500 Hz amplitude 0 35 mm acceleration 50 m s 250 000 operations minimum 100 000 operations minimum 250 000 operations minimum 24V AC DC 100 mA Degree of Protection IP65 IEC60529 Short circuit Protection 250V 10A fuse Type aM IEC60269 1 IEC60269 2 2 F Conditional 1000A Pollution Degree Operation Frequency Shock Resistance lt O D Q D Vibration Resistance MAG Damage limits Mechanical Life Electrical Life Short circuit Current Solder terminal PC board terminal M3 screw terminal Terminal Style Recommended Tightening Torque for 2 0 N m Locking Ring Screw terminal type 0 75 to 1 25 mm AWG18 to 16 Solder terminal PC board terminal types 1 25 mm maximum AWG16 maximum 20W 5 seconds maximum or 260 C 3 seconds maximum Connectable
14. er 7 016mm XA series Emergency Stop Switches Operating Instructions Removing the Contact Block First unlock the operator button While pushing up the white bayonet ring using a small screwdriver width 2 5 to 3 mm if necessary turn the contact block counterclockwise and pull out Do not exert excessive force when using a screwdriver otherwise the bayonet ring may be dam aged Bayonet Ring e Notes for Removing the Contact Block 1 When the contact block is removed the monitor contact NO contact is closed 2 While removing the contact block do not exert excessive force otherwise the switch may be damaged Panel Mounting Remove the locking ring from the operator and check that the rubber gasket is in place Insert the operator from panel front into the panel hole Face the side with the anti rotation protrusion on the operator upward and tighten the locking ring Operator Unit Rubber Gasket Anti rotation Protrusion Locking Ring e Notes for Panel Mounting To mount the XA emergency stop switches onto a panel tighten the locking ring to a tightening torque of 0 88 N m maximum using ring wrench MT 001 Do not use pliers Do not exert excessive force otherwise the locking ring may be damaged Installing the Contact Block First turn the bayonet ring to the unlocked position Bayonet Ring Unlocked Locked Align the small A marking on the edge of the operator base with the TOP marking
15. er Surface Surface for installing components 2 8 2 8x e Screw Terminal Type 1 Wire thickness 0 75 to 1 25 mm AWG18 to 16 Applicable Crimping Terminal Solid Wire gt w gt E Crimping 03 2 min Terminal Insulating Tube Kay a TFS 5 coun Che EE as 4 7 min 4 7t05 9 Wire 6 2 max e Be sure to install an insulating tube on the crimping terminal 2 Tighten the M3 terminal screw to a tightening torque of 0 6 to 1 0 N m All dimensions in mm 18 022mm XW series Emergency Stop Switches Operating Instructions Installing amp Removing Terminal Covers e XA9Z VL2 To install the terminal cover align the TOP marking on the terminal cover with TOP marking on the contact block and press the terminal cover toward the contact block Note For wiring insert the wires into the holes in the terminal cover before soldering e XA9Z VL2M To install the terminal cover align the TOP marking on the terminal cover with the TOP marking on the contact block Place the two projections on the bottom side of the contact block into the slots in the terminal cover Press the terminal cover toward the contact block TOP Marking Press the terminal cover Place the projections on the contact bock To remove the terminal cover pull out the two latches on the top side of the terminal cover Do not exert excessive force to the latches otherwise the latches may break TOP Markings Pul
16. inal cover XA9Z VL2 is ordered separately Stop Switches operator color gray Some mobile teaching pendants are easily detachable from the system and stop switches not emergency stop Types switches are required on such pendants IDEC s gray e Stop Switches colored stop switches avoid the confusion of emergency l l Type No stop switches and stop switches NC Main NO Monitor Terminal Style Contacts Contacts Solder Terminal PC Board Terminal Stop Switch PING XATE BV3OIN XATE BV301VN 2NC XA1E BV302N XA1E BV302VN NG _XATE BV303N__ XATE BV303VN ane xaTE Bva04N XATEBVSOANN e Operator is 29 mm and gray colored code N der 5 016mm XA series Emergency Stop Switches Dimensions e 029mm Operator Panel Thickness 0 5 to 3 7 n7102 ba md HY 6 5 WE 5 Do O ag PC Board Layout Bottom View Panel Cut out Terminal Cover Gasket XA9Z VL2 Locking Ring PC Board Terminal Type Solder Terminal Type e 040mm Operator Panel Thickness 0 5 to 3 7 3 P 1 7 0 I ir jul 916 7 M 2 ne 3 a co 5 N S lt PC Board Layout Bottom View i l NN Panel Cut out Terminal Cover XA9Z VL2 Locking Ring 19 8 PC Board Terminal Type Solder Terminal Type All dimensions in mm Mounting Hole Layout Terminal Arrangement Bottom View O Lia e NC main contacts only e With NO monitor contacts
17. kage quantity 10 Gasket 290 Mounting Mounting TOP Marking TOP Marking TOP Marking Locking Ring TOP Marking Locking Ring Panel Thickness 1 2 to a Panel Thickness 1 2 to 4 All dimensions in mm e The HW9Z KG1 and HW9Z KG2 switch guards are applicable for 240mm operators only Caution International industrial standards such as European Union Directive IEC60204 1 and JIS B9960 1 require that emergency stop switches must be installed in the manner in which the operator can access and operate the switches easily and prohibit the use of switch guards The HW9Z KG1 and HW9Z KG2 switch guards are used for the emergency stop switches installed on semiconductor manufacturing equipment only Do not use the switch guards for emergency stop switches installed on machine systems such as machine tool and food processing systems der 17 022mm XW series Emergency Stop Switches Operating Instructions Removing the Contact Block First unlock the operator button Grab the bayonet ring and pull back the bayonet ring until the latch pin clicks then turn the contact block counterclockwise and pull out Q Turn counterclockwise Bayonet Ring e Notes for removing the contact block 1 When the contact block is removed the monitor contact NO contact is closed 2 While removing the contact block do not exert excessive force otherwise the switch may be damaged 3 An LED lamp is built into the c
18. l out the latches IP20 Protection Terminal Cover XW9Z VL2MF To install the IP20 protection cover align the TOP marking on the cover with the TOP marking on the contact block and press the cover toward the contact block Do Press Galo TOP Marking TOP Marking Notes 1 Once installed the XW9Z VL2MF cannot be removed 2 The XW9Z VL2MF cannot be installed after wiring 3 With the XW9Z VL2MF installed crimping terminals cannot be used Use solid wires 4 Make sure that the XW9Z VL2MF is securely installed IP20 cannot be achieved when installed loosely and electric shocks may occur Contact Bounce When the button is reset by pulling or turning the NC main contacts will bounce When pressing the button the NO monitor contacts will bounce When designing a control circuit take the contact bounce time into consideration reference value 20 ms LED Illuminated Switches An LED lamp is built into the contact block and cannot be replaced Installing the Anti rotation Ring HW9Z RL Align the side without thread on the operator with TOP marking the small A marking on the anti rotation ring and the recess on the mounting panel Without thread A marking on the anti rotation ring TOP Marking Anti rotation Ring HW9Z RL Installing the Nameplate Align the side without thread on the operator with TOP marking the projection on the nameplate and the recess on the mounting panel Nameplate or S
19. med or damaged caus ing malfunction or operation failure der 9 022mm XW series Emergency Stop Switches 622 mm 4 contact Emergency Stop Switch Compact size only 37 1 mm deep behind the panel screw terminal type 48 7 mm with terminal cover Lead free ROHS compliant e The depth behind the panel is only 37 1 mm for 1 to 4 con tacts screw terminal type 48 7 mm with terminal cover e The same depth behind the panel for illuminated and non illu minated switches e IDEC s original Safe break action ensures that the contacts open when the contact block is detached from the operator e1 to 4NC main contacts and 1 or 2NO monitor contact e Push to lock Pull or Turn to reset operator e Direct opening action mechanism IEC60947 5 5 5 2 IEC60947 5 1 Annex K e Safety lock mechanism IEC60947 5 5 6 2 e Degree of protection IP65 IEC60529 e Screw terminal type is finger safe IP20 e Two operator sizes 040 and 8660 mm e Dark red Munsell 5R4 12 or bright red Munsell 7 5R4 5 14 colors are available for the non illuminated operator e Push ON illumination type available operator size 060 e UL c UL approved EN compliant Standard o Mark appro eed eae SAL VL us UL c UL File No E68961 solder terminal PC board terminal types UL c UL Listing bor screw terminal type only Oo TUV Product Service Self declaration European C 4 Commission s Low Voltage Directive Con
20. ontact block for illuminated pushbuttons When removing the contact block pull the contact block straight to prevent damage to the LED lamp If excessive force is exerted the LED lamp may be dam aged and fail to light Panel Mounting Remove the locking ring from the operator and check that the rubber gasket is in place Insert the operator from panel front into the panel hole Face the side without thread on the operator with TOP marking upward and tighten the locking ring using ring wrench MW9Z T1 to a torque of 2 0 N m maximum Operator without thread TOP marking Locking Ri Rubber Gasket HG Ining e Notes for Panel Mounting To prevent the XW emergency stop switch from rotating when resetting from the latched position use of an anti rota tion ring HW9Z RL or a nameplate is recommended Installing the Contact Block First unlock the operator button Align the small W marking on the edge of the operator with the small A marking on the yellow bayonet ring Hold the contact block not the bayonet ring Press the contact block onto the operator and turn the contact block clockwise until the bayonet ring clicks V marking marking ng NN Turn clockwise Notes for installing the contact block Make sure that the bayonet ring is in the locked position Check that the two projections on the bayonet ring are securely in place Unlatched Latched Projections a Wiring 1 The applicable wire size is 1 25
21. ring when installing the XW emergency stop switch onto a panel 110 Y manay e The anti rotation ring is used for preventing the operator from turn ing 1 5 TOP ge 922 e White e Used for solder terminals e Also applicable to the XA series e Black e Used for screw terminals e Black e Used on terminals for IP20 finger protection e Only solid wires can be used e The IP20 protection cover cannot be removed once installed 16 022mm XW series Emergency Stop Switches Nameplate ae Package EE magang Hwavo HWAVO For 40mm Operator Poyame NOY STOP HWAV 27 HWAV 27 Yellow Black HWAVSO HWAVSO For 60mm Operator OY STOP HWAV5 27 HWAV5 27 EMERGENCY STOP HWAV5F 27 HWAV5F 27PN10 a a PET film sticker e For 040mm Operator e For 060mm Operator e Sticker type Nameplate for 060mm Operator e Panel thickness when using the nameplate 0 8 to 4 5 mm 0 6 e Panel thickness when using the marking plate 0 8 to 4 mm SEMI compliant Switch Guards 022mm panel cut out e SEMI 52 0200 12 5 1 compliant e SEMATECH Application Guide for e EMO Sticker SEMI 82 93 12 4 compliant Type No HW9Z KG1 En Mo e Degree of Protection IP65 E Type NO sia En 2 2 Color Yelow Pedic of Protection IP65 En O j e Package quantity 1 Color Velow Em MH e Package quantity 1 TO o Dimensions Dimensions po NOT PINO EMO Nap e Color Yellow red legend i 2 i Pac
22. rminals 3 4 With 1NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 NC main contacts only NC main contacts Terminals 1 2 TOP 1NC Terminals on right 2NC Terminals on right and left 3NC Terminals on right left and top 1NC Terminals on top 2NC Terminals on right and left e Screw Terminal Illuminated Push ON Type EEE eed Screw Terminal Type Solder PC Board Terminal Type e The values shown above are the minimum dimensions for mounting with other 822mm pushbuttons For other control units of different sizes and styles determine the values according to the dimensions operation and wiring convenience All dimensions in mm e Non illuminated Solder Terminal PC Board Terminal Types NC main contacts only NG main contacts Terminals 1 2 With 2NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 With 1NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 TOP 1NC Terminals on right 2NC Terminals on right and left 3NC Terminals on right left and top 1NC Terminals on top 2NC Terminals on right and left Solder Terminal Type only e Solder Terminal PC Board Terminal Illuminated Types NC main contacts only NC main contacts Terminals 1 2 With 2NO monitor contacts NC main contacts Terminals 1 2 NO monitor contacts Terminals 3 4 With 1NO monitor contacts
23. t withstand rated voltage and current including the instantaneous current and voltage at switching 3 The minimum applicable load is 5V AC DC 1 mA This value may vary according to the operating environment and load NO 4 Within the 2 8 mm areas shown in the figure below ter minals touch the PC board resulting in possible short cir cuit on the printed circuit When designing a PC board pattern take this possibility into consideration 1 6 PC Board Surface for installing Solder Surface components Solder Surface Surface for installing components 2 8 2 8 e Installing Insulation Terminal Cover To install the terminal cover XA9Z VL2 align the TOP marking on the terminal cover with TOP marking on the con tact block and press the terminal cover toward the contact block Note For wiring insert the wires into the holes in the terminal cover before soldering All dimensions in mm Contact Bounce When the button is reset by pulling or turning the NC main contacts will bounce When pressing the button the NO monitor contacts will bounce When designing a control circuit take the contact bounce time into consideration reference value 20 ms Nameplate When anti rotation is not required remove the projection from the nameplate using pliers Projection O Nameplate Handling Do not expose the switch to excessive shock and vibration otherwise the switch may be defor
24. tact Ratings NC main contacts NO monitor contact Screw Terminal Type 250v Solder Terminal Type UL508 CSA C22 2 No 14 EN60947 5 1 EN60947 5 5 Rated Insulation Voltage Ui 300V Terminal Type Rated Current Ith 5A Rated Operating Voltage Ue 125V 250V BA Note 1 3A 1 5A 5 O W O 2 Q Resistive Load gt O N A H GUN Io Inductive Load Main AC 15 3A Note 2 Contacts Resistive Load Inductive Load ft CE p 0 AC 50 60 Hz 0 3 3 s gt tee O AC 14 Resistive Load DC 12 Inductive Load DC 13 e Minimum applicable load 5V AC DC 1 mA reference value Operating area may vary according to the operating conditions and load types e The rated operating currents are measured at resistive inductive load types specified in JIS C8201 5 1 Note 1 Solder terminal PC board terminal types 3A Note 2 Solder terminal PC board terminal types 1 5A Illumination Ratings Rated Voltage Operating Voltage Rated Current 24V AC DC 24V AC DC 10 15 mA Rated Operating Current 2A 1A ACD Load 6 2A 4A 1A 2 Inductive Load O U 0 1A BE gt Direct Opening Action Specifications IEC60947 5 1 EN60947 5 1 IEC60947 5 5 Note EN60947 5 5 Note JIS C8201 5 1 UL508 CSA C22 2 No 14 Non illuminated 25 to 60 no freezing LED illuminated 25 to 55 no freezing 45 to 85 RH no condensation 45 to 80 Push to lo
25. witch Guard When anti rotation is not required remove the projection from the nameplate or switch guard using pliers Projections Switch Guard Handling Do not expose the switch to excessive shocks and vibra tions otherwise the switch may be deformed or damaged causing malfunction or operation failure der 19 AN Safety Precautions switches Specifications and other descriptions in this catalog are subject to change without notice e Read the user s manual to ensure correct operation before starting installation wir ing Operation maintenance and inspection of the XA and XW emergency stop 7 31 Nishi Miyahara 1 Chome Yodogawa ku Osaka 532 8550 Japan IDEC IZUMI CORPORATION tet 81 6 6398 2571 Fax 81 6 6392 9731 IDEC CORPORATION USA 1175 Elko Drive Sunnyvale CA 94089 2209 USA Tel 1 408 747 0550 Toll Free 800 262 IDEC Fax 1 408 744 9055 E mail opencontact idec com www idec com IDEC CANADA LIMITED Unit 22 151 Brunel Road Mississauga Ontario L4Z 1X3 Canada Tel 1 905 890 8561 Toll Free 888 317 4332 Fax 1 905 890 8562 IDEC ELECTRONICS LIMITED Unit 2 Beechwood Chineham Business Park Basingstoke Hampshire RG24 8WA UK Tel 44 1256 321000 Fax 44 1256 327755 E mail idec uk idec com IDEC ELEKTROTECHNIK GmbH WendenstraBe 331 D 20537 Hamburg Germany Tel 49 40 25 30 54 0 Fax 49 40 25 30 54 24 E mail service idec de www idec de IDEC AUSTRALIA PTY LT