Home

VictoriaSTM-16/OC-48 Plus

image

Contents

1. Insertion mode single burst repetitive burst and rate 1 1 x 10 to 0 9 x 10 9s Alarms Insertion and detection of LOS LOF TIM S AIS L RDI L AIS P LOP P UNEQ P RDI P TIM P PLM P LOM V AIS V LOP V UNEQ V RDI V RFI V TIM V PLM V LSS pattern AIS Insertion mode continuous burst of M frames with alarm repet itive M N burst Pointer Events Increment decrement manual value with or without NDF invalid pointer in STS 3c STS 1 VT 2 VT 1 5 G 783 0 172 pointer sequences Programming of SS bits Tributary frequency offset PDH Structure 140 and 8 Mbit s according to G 751 G 742 G 704 framed and unframed 34 Mbit s according to G 751 or optionally according to G 832 for transporting 14 TU 12s options 30553 305531 or unframed PCM30 31 frame structure with without CRC for 2 Mbit s sig nals Test signal in 64 or N x 64 kbit s CAS signalling setup and display of the CAS multiframe and spare bits of frame 0 Errors Insertion and detection of code errors FAS errors CRC errors REBE slips and bit errors For G 832 framing in 34 Mbit s insertion and detection of EM REI LP REI BIP 2 Insertion mode single burst repetitive burst and rate 1 1 x 10 to 0 9 x 10 9s Alarms e Insertion and detection of LOS AIS LOF RAI CRC LOM MAIS CAS LOM MRAI LSS and AIS pattern For G 832 framing in 34 Mbit s insertion and detection of OOF LOF TIM R
2. The Victoria STM 16 OC 48 Plus has all the features of a portable tester Thanks to its small size and light weight this battery fed tester is the ideal solution for field work The unique measurement features of Victoria make it suitable for a number of applications both in and out of service Installation Acceptance and commissioning Monitoring and surveillance Repair and maintenance Product Highlights 3G UMTS Network Telecom networks have evolved towards the integration of SDH SONET ATM and IP technologies under one single architecture thus making it easier to bring today s new telematics applications into service The UMTS 3G is a very typical example of a network where several technologies are merged and these need to be separetely tested After testing the physical layer the ATM layer and the ATM Adaptation Layer AAL must also be tested Circuit Switched Network Victoria Switched g Network Node B ATM in E1 E3 STM 1 interfaces The 3GPP 3G Partnership Project defines a rich set of protocols between the end user and other networks These protocols sit Datasheet 8 VictoriaSTM 16 0C 48 Plus The Smartest Solution for Testing SDH SONET ATM PDH T Carrier above ATM Adaptation Layers 2 and 5 AAL 2 and AAL 5 The lu and the lub interfaces use the AAL 2 and AAL 5 to carry both user traffic and control traffic By generating and emulating AAL2
3. F1 N1 and N2 bytes Bit error counter rate and errored seconds Seconds with alarm counter for LSS APS Measurement of disruption time for any STM N OC N Tributaries PDH T Carrier SDH SONET Range 1 msto 10s Resolution 1 ms Optical Power Measurement Range 0 to 28 dBm 2 to 40 dBm with external optical mod ules Resolution 1 dB Frequency Measurement In Hertz and bit s with deviation in ppm ITU T ANSI in range or out of range indication TIE measurement based on Pointer Justification Events Frequency Offset of the Transmission Clock Up to 40 ppm in steps of 0 01 ppm for the integrated optical interfaces Up to 20 000 ppm in steps of 0 01 ppm for electrical interfaces and for optical interface at 155 Mbit s with external module Remote Control Via RS 232C interface and SCPI commands Optional remote control with advanced GUI option CR3090 Printout of Results Totals and periods events trace in real time or result files header with configuration and results Transfer to PC Via RS 232C port Autosave Ifthe mains supply fails the current context is saved and the measurement continues when power source is restored Automatic Measurements and Storing Measurements can last up to 999 days with automatic start stop They are saved with name date time the configura tion of the tester at the time of the measurement and if desired a text c
4. REI EM BIP 8 Simultaneously detected with hierarchical inhibition Alarms Insertion Detection LOF AIS RDI Detection of LOS E1 Frame according to G 704 with CRC 4 and ATM mapping according to G 804 NFAS TS16 bytes Editing Display of Si bits and TS16 Errors e Insertion mode manual rate burst continuous burst HDB3 and AMI code FAS CRC 4 REBE E bit Simultaneously detected with hierarchical inhibition Alarms Insertion Detection of LOF AIS RAI CRC LOM Detection of LOS ATM layer Generator Mapping of cells in the frames at all physical layers UNI NNI interfaces byte aligned Generation of 2 types of stream foreground and background Cell scrambler can be disabled enabled Rate adaptation with the insertion of unassigned or idle cells Test cells Editing of GFC VPI VCI PTI CLP Programmable payload Selection of AALO AAL1 AAL2 AAL3 4 preconfigured amp AAL5 0 191 full editing in Hex or ASCII PRBS 215 1 PRBS 223 1 all 1s all Os 1010 1000 8 bit word Traffic profiles Indication of Peak Cell Rate PCR Sustainable Cell Rate SCR and Maximum Burst Size MBS Resolution of 1 cell s Foreground stream CBR VBR 2CBRs VBR on off VBR PCR SCR and MBS programming and UBR Background streams CBR andVBR 2CBRs ATM traffic analyzer Demapping of cells UNI NNI interfaces amp HEC delineation Enabling Disabling of continuity che
5. Delay parameters CTD 1 CDV 2 CDV IAT Current max min amp average values Typical deviation amp variability coefficient for 2 CDV IAT Monitoring of ATM traffic Bandwidth for link and connections current max min and aver age values in cells s and bit s EFC and CLP bandwidth indication Histograms of all bandwidths analyzed link connections total with CLP 1 connection with CLP 1 etc AAL1 Generation amp Analysis Generation of AAL1 fields AAL1 payload filled with PRBS or fixed test sequence Analysis count seconds with ratio of Errored cells SN parity violation Loss of cells SN hop detected Misinserted cells SN out of sequence AAL2 Generation amp Analysis Generation 3 foreground amp 1 background AAL2 connections Programming CPS Packet size and bandwidth for each connec tion Editing CPS Packet header bytes CID UUI Definition of SAP for each AAL2 foreground connection CPS SSSAR SSETD Definition of SSETD packet size and editing trailer fields UUI Cl amp LP 1 foreground filled with PRBS or fixed test sequence Remain ing foreground connections amp background with word Analysis Bandwidth of 3 selectable AAL2 connections identified by CID amp UUI optional amp Total of AAL2 link Packet size analysis for 3 AAL2 connections at the SAP selected CPS Packet size or SSETD packet size Analysis of errors CPS PDU parity
6. EFAS OOF B1 B2 MS REI HP B3 HP REI LP B3 LP REI BIP 2 slips and bit errors Insertion mode single burst repetitive burst and rate 1 1 x 10 to 0 9 x 10 9s Alarms e Insertion and detection of LOS LOF RS TIM MS AIS MS RDI AU AIS AU LOP HP UNQ HP RDI HP TIM HP PLM TU LOM TU AIS TU LOP LP UNQ LP RDI RFI LP TIM LP PLM LSS pattern AIS Insertion mode continuous burst of M frames with alarm repet itive M N burst Pointer Events Increment decrement manual value with or without NDF invalid pointer in AU 4 AU 3 TU 3 TU 2 TU 12 and TU 11 G 783 0 172 pointer sequences Programming of SS bits Tributary frequency offset SONET General According to ANSI 105 1995 and Telcordia GR 253 Programmable scrambler and background Datasheet Mappings STS 48c STS 12c STS 3c bulk or with framed E4 STS 1 bulk or with framed DS3 or E3 VT 2 bulk or with framed E1 asynchronous or byte synchro nous VT 1 5 bulk or with framed DS1 Programmable Bytes Display of all bytes and editing in hexadecimal or by descriptor of SOH A1 A2 JO C1 LOH K1 K2 S1 STS POH J1 C2 G1 H4 K3 VT POH J2 V5 K4 JO J1 J2 Trail Trace Generation analysis and expected 16 and 64 byte messages in JO J1 and J2 Errors Insertion and detection of ECOD EFAS SEF B1 B2 REI L STS B3 REI P VT B3 REI V BIP 2 slip and bit errors
7. and AALS traffic commissioning of connections as well as in service measurements are performed on 3G mobile networks Remote Control A Victoria STM 16 OC 48 Plus tester can be controlled from anywhere in the world thanks to the remote control system that makes use of the Internet This enables you to test the whole network manage and compare results and give help to your field technicians from one single control centre The following can be highlighted from among the basic remote control features of Victoria Graphical interface based on intuitive easy to use windows Simultaneous control of many instruments Client Server architecture fully integrated into the Internet ADM Victoria RClient RClient RServer TCP IP POTS a Aas TrendCommunications Tests in International Gateways The current technological needs call for testers that meet the varying standards of different countries It is an essential requirement that a tester can interact with both European and American interfaces Victoria High capacity DXC Victoria has the capacity to work with both SDH and SONET or PDH and T Carrier at the same time and this makes it a necessary tool in testing high capacity gateways that interconnect SDH and SONET backbones Besides this the use of some ANSI interfaces is becoming more common in Europe For example the use of DS3 signals at 45 Mbit s is incre
8. burst B1 B2 REI L BIP P REI P Simultaneously detected with hierarchical inhibition Alarms Insertion Detection of OOF LOF TIM S AIS L RDI L AIS P Detection of LOS LOP P RDI P PLM P TIM P UNEQ P Pointer actions Editing of H1 and H2 value on generation and display of same on reception Insertion Detection of invalid pointer and new value with without NDF indication Insertion Detection of increment decrement of pointer Manual or in intervals of 1 ms to 8 hours DS3 C bit frame T1 107 1995 ATM cell mapping options G 804 amp T1 646 1995 direct mapping or using PLCP subframe Errors Insertion mode manual rate burst continuous burst BPV M bit F bit P bit and C bit parity FEBE Simultaneously detected with hierarchical inhibition Alarms Insertion Detection of OOF RAI AIS Idle signal Detection of LOS Errors PLCP Insertion mode manual rate burst continuous burst PLCP FAS PLCPBIP 8 FEBE errored POI Simultaneously detected with hierarchical inhibition Alarms PLCP Insertion Detection of LOF RAI Loss of POI E3 G 832 structure Frame according to G 832 ATM cell mapping according to G 804 MA NR and GC bytes Editing Display in hexadecimal or by descriptor Trail trace messages TR Generation Analysis of G 831 messages of 16 bytes with CRC and ECRC status Errors Insertion mode manual rate burst continuous burst FAS
9. violation CPS PDU SN vio lation errored HEC CPS Packet errored CRC SSETD packet SSSAR or SSETD packet length violation AAL5 Generation amp Analysis Generation Programming of the CPI CPS UU fields and selection of packet size Payload filled with PRBS or fixed test sequence Analysis Bandwidth of AAL5 packets in packets s and bytes s current maximum minimum and mean value Size value of the received AAL5 packets current maximum and minimum Error Analysis CPI fields maximum length exceeded incorrect lenght abort function and CRC error Functions Autodetection VPIs VCIs Identification of active VPIs VCls Detection of AAL type Automatic identification of AAL Scan of specific cells Unassigned OAM ILMI Selective capture Cell capture with filtering by header value Display of contents with AAL decoding Time stamp showing interval between captures IP layer Functions performed by Victoria and a PC running software module IP Ping RFC 1483 1577 Ranked list of IP addresses Use of bandwidths Traffic composition by protocol TCP UDP ICMP IGMP and by application WWW FTP Telnet DNS SNMTP e Size and frequency of IP TCP and UDP packets Filters can be programmed to capture traffic for one single VCC connection or a range of connections Datasheet General Dimensions 257 x 147 x 70 mm Weight 2 4 kg 12x 9 cm colour touch screen Autonomy 2 h
10. DI UNEQ PLM TU AIS TU LOP TU LOM LP UNQ LP RDI RFI LP TIM LP PLM Insertion mode continuous burst of M frames with alarm repet itive M N burst 45 Mbit s Structure Framed M13 and C bit according to G 752 G 704 also unframed Errors Insertion and detection of BPV M BIT F PAR P PAR C PAR FEBE slips and bit errors Insertion mode single burst repetitive burst and rate 1 1 x 10 to 0 9 x 109s Alarms Insertion and detection of LOS AIS LOF Blue Alarm IDLE RAI Yellow Alarm LSS and AIS pattern Insertion mode continuous burst of M frames with alarm repet itive M N burst 1 5 Mbit s Structure SF amp ESF framing according to ANSI T1 400 1995 SLC 96 framing according to Telcordia TR TSY 00008 and also unframed Fractional DS1 DS1 with test pattern in N x 64 amp N x 56 kbit s Errors Insertion and detection of BPV EFAS ECRC and bit errors Insertion mode single burst repetitive burst and rate 1 1 x 10 to 0 9 x 10 9s Alarms Insertion and detection of LOS LOF RAI LSS and line AIS Insertion mode continuous burst of M frames with alarm repet itive M N burst Signalling Generation and analysis of Robbed Bit signalling Generation and analysis of Data Link messages in ESF amp SLC 96 framing TCM Generation and analysis of N1 and N2 Events generated TC IEC TC OEI TC REI TC AIS TC LTC TC UNEQ TC ODI TC RDI
11. TC TIM Detection display performance calculation and storage of events TC IEC TC OEI TC REI TC AIS TC LTC TC UNEQ TC ODI TC RDI TC TIM Datasheet B3 or BIP 2 compensation Analysis and generation of APId Access Point Identifier Pattern The following patterns can be generated PRBS11 PRBS15 PRBS20 PRBS23 PRBS31 normal or inverted Word user defined all zeros all ones 1010 1000 and 1100 Functions Results Counters errored seconds and rate for all events errors alarms and pointer events Trace Events are shown graphically in time plots and histograms that have advanced filter search identification and quantization functions and a zoom from 1 sto 1h SoftLEDs 10 tricolour external LEDs with on screen labelling showing up to 80 simultaneous events Performance Performance measurements in line with ITU T G 821 M 2100 M 2101 1 and G 826 Counter rate unavailability and PASS FAIL indication of compliance with programmed objectives Round Trip Delay in all interfaces range from 1 us to 10 s Autoconfiguration Identification of the incoming signal parameters network SDH SONET T Carrier PDH or G 832 bit rate line code optimal gain frame structure mapping PRBS autosearch FastScan Search the incoming signal for all types of errors alarms and events Transparency Test Generation and analysis of PRBS pattern in DCC channels or E1 E2
12. asing in such applications as MPEG video transport Alarm and Error Scan SDH SONET signals are formed by multiplexed lower order tributaries Some of these tributaries may get affected by errors or alarms whereas others remain intact ko N unavailable path AIS E3 DXC Victoria SCAN Path A OK Path B OK Path C E3 AIS Datasheet It is necessary to define the type of error and the part of the SDH SONET signal affected to find out which link or network element is causing the problem The scan function makes it possible to locate and isolate network events automatically This function works at any hierarchical level and it can be used for any type of mapping or tributary signal The path trace analysis and TCM capabilities of Victoria are also very useful when identifying the affected link Evaluating Analog Parameters Before carrying out any digital measurements it must be checked that the analog parameters of the signal remain within certain margins Victoria makes it possible to instantly check that the optical power and the frequency of the received signal are within the margins accepted by the ITU Ideal incoming signal Incoming signal power too low PPPPLDILI Incoming signal frequency out of range WV WV With Victoria STM 16 OC 48 Plus it is safe to establish connection to a link to carry out an optical power measurement as the receiver is protected against any overload t
13. ck cell scrambler and header correction functions Simultaneous analysis of fore amp background streams Datasheet Selection of streams for analysis e Editing of VPI VCI Selection of payload type for foreground stream Selection of AALO AAL1 AAL2 or AAL5 0 191 PRBS word and live traffic OAM cells Generation of segment and end to end F4 and F5 flows F4 VP AIS VP RDI VP CC VP LB F5 VC AIS VC RDI VC CC VC LB Editing of loopback cells Detection of segment and end to end F4 F5 alarm conditions F4 VP AIS VP RDI VP LOC F5 VC AIS VC RDI VC LOC Errors Insertion mode manual rate burst continuous burst Single or double cell header error CER CLR CMR and CBER ATM alarms Insertion of LCD All 1s test sequence P AIS and LSS Detection of LCD LPAC P AIS and LSS Results Measurements between 1 min and 999 days with automatic start stop All events shown in trace with resolution from 1 s to 1 h Time plots and histograms with advanced identification search and quantification functions Filters by type of event ATM headers Count of errored discarded and corrected cells seconds affected and rate HEC delineation test showing seconds with LCD QoS monitoring Error parameters Count of received non conforming errored lost and misinserted cells Calculation of CER CLR CMR CBER amp seconds affected Performance parameters SECBR SES ES and Unavailable time
14. hat might damage it Frequency measurements are not limited only to presenting measurement results in Hertz but it is also possible to make sophisticated synchronization measurements Victoria TIE Time Interval Error measurement TIE is caused by pointer movements in SDH and SONET Programming and analysis of standard pointer sequences to test network tolerance Frequency offset generation in PDH T Carrier tributaries in SDH or SONET signals Tandem Connection Monitoring In a multi operator environment there are some companies that offer transmission services of other operators or companies In these circumstances it is essential to delimit responsibilities whenever a problem occurs The Tandem Connection Monitoring TCM protocol has been designed for this purpose ERRORS Operator C Operator B Operator A The TCM mechanism makes it possible to analyse the part of the path where a problem occurs when an SDH SONET signal is crossing the network and arrives degraded at its destination The Victoria STM 16 OC 48 Plus generates and analyses all type of TCM events to check that this protocol is working correctly Automatic Measurements The ability to make automatic measurements by using macros makes Victoria STM 16 OC 48 Plus a powerful tool in carrying out repetitive tests such as bringing into service and type approval of network equipment With the the macro utility you can Ca
15. ions 3095C2 3095C4 Via external optical micromodules fed by the equipment for 34368 kbit s option 305531 51840 kbit s option 305511 and 155520 kbit s Clock Clock sources Internal according to G 812 Recovered from the incoming signal External 1544 2048 kHz with BNC connector External coded G 703 at 1544 kbit s and 2048 kbit s with BNC or balanced connector with 0 and 20 dB gain accessory AD340 Modes SDH SONET PDH T Carrier termination SDH SONET PDH T Carrier bridged SDH SONET mux demux Through mode for all the interfaces SDH General According to G 707 and 0 181 Programmable scrambler and background Mappings C 4 16c in STM 16 C 4 4c in STM 4 and STM 16 C 4 unstructured or with framed E4 in STM 1 STM 4 and STM 16 C 3 unstructured or with framed E3 or DS3 in STM 0 STM 1 STM 4 and STM 16 both with an AU 3 or AU 4 C 12 unstructured or with framed E1 asynchronous or byte synchronous in STM 0 STM 1 STM 4 and STM 16 C 11 unstructured or with framed DS1 in STM 0 STM 1 STM 4 or STM 16 Programmable Bytes Editing and display in hexadecimal or by descriptor RSOH A1 A2 JO C1 MSOH K1 K2 S1 HO POH VC 4 VC 3 J1 C2 G1 H4 K3 LO POH VC 3 J1 C2 G1 H4 K3 LO POH VC 12 VC 11 V5 J2 K4 Trail Trace Generation analysis and expected 16 and 64 byte messages in JO J1 and J2 Errors Insertion and detection of ECOD
16. omment by the user ATM ATM Interfaces STM 1 According to 0 181 and G 707 ATM cells mapped according to 1 432 2 Scrambler can be disabled enabled Default value of SS bits 10 RSOH MSOH and HO POH bytes Editing Display in hexadecimal or by descriptor of C1 S1 K1 K2 C2 G1 H4 and K3 Trail trace messages JO and J1 Generation Analysis of G 831 messages of 16 bytes with CRC and ECRC status Errors Insertion mode manual rate burst continuous burst B1 B2 MS REI HP B3 HP REI Simultaneously detected with hierarchical inhibition Alarms e Insertion Detection of OOF LOF RS TIM MS AIS MS RDI AU AIS AU LOP HP RDI HP SLM HP TIM HP UNEQ Detection of LOS Pointers Editing of H1 and H2 value on generation and display of same on reception Datasheet Insertion Detection of invalid pointer and new value with without NDF indication Insertion Detection of increment decrement of pointer Manual or in intervals of between 1ms and 8 hours STS 3c OC 3c According to ANSI T1 105 1995 ATM mapping according to T1 105 02 1995 Scrambler can be disabled enabled Default value of SS bits 00 SOH LOH and STS POH bytes Editing Display in hexadecimal or by descriptor of C1 S1 K1 K2 C2 G1 H4 and K3 Trail trace messages JO and J1 Generation Analysis of G 831 messages of 16 bytes with CRC and ECRC status Errors Insertion mode manual rate burst continuous
17. ours two battery packs RF EMI ESD and Electrical Safety Radiated EMI EN50081 1 Immunity to EMI EN 50082 1 ESD IEC801 2 4 kV contact Electrical safety EN61010 1 Environmental conditions Operates at 0 to 45 C Storage 40 to 70 C Humidity 5 to 90 without condensation O Ordering Information Base Configurations 3095C1 Victoria STM 16 OC 48 Plus 1310nm FC PC Colour Handheld Analyser Generator 2 8 34 140 155 622 Mbit s Optional 2488 52 45 1 5 34 Mbit s G 832 adv features ATM over 2 34 45 amp 155 Mbit s 3095C2 Victoria STM 16 OC 48 Plus 1550nm FC PC Colour Handheld Analyser Generator 2 8 34 140 155 622 Mbit s Optional 2488 52 45 1 5 34Mbit s G 832 adv features ATM over 2 34 45 amp 155 Mbit s 3095C4 Victoria STM 16 OC 48 Plus 1310 amp 1550nm FC PC Colour Handheld Analyser Generator 2 8 34 140 155 622 Mbit s Optional 2488 52 45 1 5 34 Mbit s G 832 adv features ATM over 2 34 45 amp 155 Mbit s Options Transmission Options 30955 STM 16 OC 48 TEST 30551 STS 1 STM 0 Electrical Test 305511 OC 1 STM O Optical Test 30552 DS 3 Test 30553 G 832 34 Mbit s Electrical Test 305531 G 832 34 Mbit s Optical Test 30554 DS 1 Test 30561 Advanced options TCM M N alarms G 783 sequences tributary offset CR3090 Remote control with graphical user interface ATM Option
18. rry out complex measurements with a single keypress Help field technicians throughout the measurement by means of the graphical user interface of the tester Program customized pass fail tests that show the result by dis playing a label on the screen Datasheet Create new specialized measurements that the user can create such as repetitive BERT used when installing radio links Technical Specifications TRANSMISSION Electrical Interfaces BNC default DIN 1 6 5 6 option DIN55 Rates 2048 kbit s HDB3 and AMI 8448 kbit s HDB3 and AMI 34368 kbit s HDB3 139264 kbit s CMI 155520 kbit s CMI Optional 1544 kbit s B8ZS and AMI option 30554 44736 kbit s B3ZS amp AMI option 30552 pulses DS3 HI and DSX 3 with accessory AD045 51840 kbit s B3ZS option 30551 Balanced Bantam accessory AD300 Siemens accessory AD320 and RJ48 accessory AD322 for 1544 kbit s and 2048 kbit s Interfaces according to G 703 ANSI T1 102 and G 772 Gain 0 20 26 30 dB from 1544 kbit s to 51840 kbit s 0 20 26 dB for 139264 kbit s and 0 20 dB for 155520 kbit s Optical Interfaces Built in connectors for 155520 kbit s 622080 kbit s and 2488320 kbit s Interfaces according to the ITU T G 957 L 16 1 and L 16 3 FC default SC option 3090SC or ST option 3090ST con nectors Automatic disconnection of the receiver for overload protection 1310 nm transmitter configurations 3095C1 3095C4 and 1550 nm transmitter configurat
19. s 40801 ATM generation amp analysis it includes 2 34 and 155 Mbit s 40702 Extends ATM capabilities over 45 Mbit s 40802 Adds AAL2 generation amp analysis 40805 Adds AAL5 generation amp analysis IPProbe PC software for statistical analysis of IP traffic over ATM Main Accessories and Replacement Items PR100 1 Portable battery powered printer AD045 6 dB Line Simulator for 45 Mbit s AD210 High impedance attenuating probe AD300 Balun Adapter 75 Q BNC to 100 QBantam Jack AD320 Balun Adapter 75 Q BNC to 120 Q Siemens AD322 2 Mbit s Balun Adapter 2 x BNC 75 Qto RJ 48 AD340 Coded 1544 and 2048 kbit s External Clock 0 and 20 dB for 1544 kHz 2048 kHz 1544 kbit s and 2048 kbit s AD10FC FC aerial 10 dB attenuator m f AD15FC FC aerial 15 dB attenuator BT410 Ni MH battery pack MOCD3095 User manual UG3095 English Quick User Guide UG3095S Spanish Quick User Guide MS3095 English Service and Calibration Manual for Victoria STM 16 OC 48 Plus 3095C CA220 75 QBNC m BNC m coaxial cable 2 m CA230 75 QBNC m BNC m coaxial cable 2 m CA231 75 QBNC f DIN 1 6 5 6 m coaxial cable 2 m CA232 75 QBNC m DIN 1 6 5 6 f coaxial cable 2 m CA260 RS 232C cable for remote control sub D 9 f 9 m CP2FC Optical cable 2 m with FC PC FC PC connectors CP2SC Optical cable 2 m with SC SC connectors Datasheet CP2ST Optical cable 2 m with ST ST connec
20. tors CPFC2SCPC Optical cable 2 m with FC PC SC PC connectors Contact Trend Communications for information on additional options and accessories ds va3095 03 uk 02 09 02 Trend Communications S L Pujades 60 08005 Barcelona Espa a Aa CS TrendCommunications web www trendcomms com e mail infoline trendcomms com International 44 0 1628 524977 UK ianen 01628 524977 Espa a 93 300 3313 Deutschland 089 32 30 09 11 France 01 69 35 54 70 India 22 8597 463 4 US iena 256 461 0790 TrendCommunications Ltd reserves the right to change their product specifications without prior notification This document is for information only and does not represent a contractual obligation A Member of the Telemetrix plc These specifications are subject to change without prior notice

Download Pdf Manuals

image

Related Search

Related Contents

Data Sheet  NX M12-A NX M15-A NX M22-A NX M25-A  "service manual"  CDX—44  Telex RADIOCOM TR-1 User's Manual  Vita-Mix Blender PROFESSIONAL SERIES 300 User's Manual    extra - BASF Canada  Lasko 2012 fan  

Copyright © All rights reserved.
Failed to retrieve file