Home

vistaHD user manual

image

Contents

1. 158 Load preset 6 Pressing this button loads the PAL normal preset memory 159 Back Pressing the button takes you to the previous level of menus Go To 48 Menus 148 151 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Pressing the prev button on the panel will take you to the previous menu in the nested menu sequence Go To Menus 152 155 Menus 160 163 User memories menu 1 4 Menu Num Heading Function 160 Load user memory 1 Pressing this button loads the first user memory For details on the user memories see section 3 4 3 161 Load user memory 2 Pressing this button loads the second user memory 162 Load user memory 3 Pressing this button loads the third user memory 163 Back Pressing the button takes you to the previous level of menus Go To Menus 164 167 User memories menu 2 4 Menus 148 151 Pressing the next button on the panel will take you to the next menu in the nested menu sequence Go To Menus 164 167 Menu Num Heading Function 164 Load user memory 4 Pressing this button loads the fourth user memory For details on the user memories see section 3 4 3 Load user memory 5 Pressing this button loads the fifth user memory 166 Load user memory 6 user Load user memory 6 6 Pressing
2. 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 172 175 User memories menu 4 4 To show this memory as the loaded memory you will need to immediately load it once it s saved using the appropriate user mem recall button 3 4 4 Naming User Memories The user memories can be named with up to 12 characters To do this plug in a PS 2 Keyboard into a Flexipanel and select the appropriate processor card with a device button See Figure 6 L 2S or LE 2M connections for connector location To name memory 1 625v1 050309 1 Hit F9 function key The LCD displays will change to text entry mode 2 Type M01 625v1 and then press enter 3 Type M02 050309 and then press enter 4 You may get a not acknowledged message from either of the above this does not matter Other memories can be named in the same way but changing the 01 and 02 to other numbers for user memory 2 use 03 and 04 for mem 3 use 05 and 06 etc 3 5 Tamper Locking the Le e The user can lock specific menus or all the menus on the LE 2 so that it cannot be adjusted with a manual control panel This does not effect automation To do this plug in a PS 2 Keyboard into a Flexipanel and select the appropriate processor card with a device button See Figure 8 Flexipanel FP 9 controls for connector location To lock only menu 5 1 Hit F9 function key The LCD displays will change to text entry mode 2 Type LO5
3. Le e Legaliser module uiith composite RGB and YCC gamut correction user manual User Manual Versions Versions Changes Date S W Ver 1 0 First Version 16 06 08 1 00 1 1 Comp RGB mode added 18 11 08 1 03 1 2 User memories and user presets and user preset settings 04 12 08 1 04 updated 1 3 Added new section explaining how presets are disabled when 25 01 10 1 15 the unit has just been powered up without video and menu locking unlocking 1 4 Added blanking settings restored when video standard 18 02 10 2 0 changed tamper locking of user menus 1 5 Change to new single piece 3G compatible hardware 02 06 10 2 0 1 6 Corrected EBU R103 references 15 09 10 2 0 1 7 Added KARMAudioRT option 13 01 11 2 1 2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Table of Contents rice T a eA 6 1 1 TENSE 6 1 2 Associated Equipment for the LE 2 7 eR MT 9 2 Connections on the EE 2 proOdllolu iio o Rp aene 9 3 Operation REM 11 3 1 General Flexipanel 0 8 2 11 3 1 1 Device BUMDFIIS aiutano ceo Au ict Diosa ood unaq s
4. Menu Num Heading Function 212 Ring suppression This menu cycles the Ring status suppression between off on and auto For more information on the ring 55 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com suppression Go To 3 3 1 213 Ring suppression This menu sets the value for the high high clip clip limit of the ring suppression Values are in mV 214 Ring suppression This menu sets the value for the low low clip clip limit of the ring suppression Values are in mV 215 Back Pressing the button takes you to the previous level of menus Go To Menus 100 103 Menus 216 219 Ring suppression NTSC IRE Menu Num Heading Function 216 Ring suppression This menu cycles the Ring status suppression between off on and auto For more information on the ring suppression Go To 3 3 1 217 Ring suppression This menu sets the value for the high high clip clip limit of the ring suppression Values are in IRE 218 Ring suppression This menu sets the value for the low low clip clip limit of the ring suppression Values are in IRE 219 Back Pressing the button takes you to the previous level of menus Go To Menus 100 103 Menus 220 223 Monitor output menu Menu Num Heading Function Indicate output This menu sets the type
5. 1 N A A 19 N A N A 2 N A START S A oftwr 19 ARE H N A N A 3 N A YOU A HRSURE 19 1 4 R A YE WwW S 19 Gr N A N A 5 N A A 19 N A N A 6 N A START F A actry 19 ARE H N A N A N A YOU A JHSURE 19 Gg 0 1 8 R A Plea WwW se 19 RD 4 0 1 8 B YE Wai S t 19 RD 4 0 1 8 C 19 Gr N A N A 9 N A A 20 LE 2 N A N A 0 N A FILE A TIMES 20 IS UPGHIS N A N A 1 N A RECHOUT A IN 20 N A N A 2 N A RADINGMHEI A VED 3 MINS 69 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 20 IF NO N A N A 3 N A H A 20 Luma 0 200 4 R MGain 0 A w 20 0 200 5 R Chroma G 0 A w ain Mf 99 20 Black 652 300 6 R HLift 36 A W 20 Gr N A N A 7 N A A 20 Ring 0 2 8 R Supprn A OF AUT M w F O AN L 20 High Clip 108 9 R 96 Vari 7 A W able 21 Low Clip 654 0 R 68 Vari A W able 21 Gr N A N A 1 N A A 21 Ring 0 2 2 R Supprn A OF AUT M w F O AN L 21 High Clip 986 3 R mV Vari A W able 21 Low Clip 652 4 R mv 36 Vari A Ww able 21 Gr N A N A 5 N A A 21 Ring 0
6. 246 Ls Rs and LFE Sets the embedded audio channel Channel Numbers Numbers for channels Left Surround Right Surround and Low Frequency Effects Setting O disables that channel in the loudness calculation and true peak correction The LFE channel is never included in the loudness calculation but is subject to 59 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com loudness and true peak correction if not set to 0 247 Back Pressing the button takes you to the previous level of menus Go To Menus 12 15 Menus 248 251 KARMAudioRT Loudness processing menu this menu is only operational with the KARMAudioRT option K Menu Num Heading Function 248 Attack Rate This adjusts the attack rate of the loudness correction in loudness units per second 249 Decay Rate This adjusts the decay rate of the loudness correction in loudness units per second 250 Window This is the duration of the averaging window used to determine the short term loudness of the source audio 251 Back Pressing the button takes you to the previous level of menus Go To Menus 176 179 60 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales
7. 26 3 4 1 Power on memory T 26 3 4 2 Preset memories 26 3 4 3 User Memories a rrrssssssssssssa 27 3 4 4 Naming User Memories 28 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 3 5 Tamper Locking the LE 2 28 3 5 1 Globally locking the user menus 28 mb ed epepki ie ieni areena en eos d sey pa pudo 29 d TO Board OPI Ss o ED IR ELEME E ERR a E 29 3 6 2 Configuring tallies on the etherbox 29 3 Resetting the dB ccce 29 38 Software 01 8 8 etie sie nae De te re Soe ee 30 4 The LE 2 Ment Sel etaed adu oce ended edades 31 5 Technical Appendix 61 5 1 GPI Tally RS232 technical information 61 5 1 1 RS232 Interface isinen 61 5 1 2 LTC Linear Time code Interface 61 5 2 On Board a
8. 3 2 2 Selecting the legalisation type This is a view of the top level display of the LE 2 Menus 00 03 Top Level Menus To select the type of legalisation required press menu B to cycle through the available options These are Off no processing of the input video will be performed by the Le a e RGB the picture will be RGB legalised according to the RGB clip and knee settings YCC the picture will be YCC legalised according to the YCC clip and knee settings Comp the picture will be Composite legalised according to the Composite clip and knee settings Comp RGB the picture will be firstly Composite legalised and then RGB legalised 3 2 3 Setting the legaliser domain It is important to note that in order for the unit to do the correct colour space conversion required the manner in which the data is converted needs to be specified This must be done regardless of which type of legalisation is required This is selected from the below menu found by navigating to Setup Comp Menus 100 103 Composite main menu The domain options are listed below e Auto This uses the frame rate to calculate which conversion to use o 29 97fps 30fps 59 94fps and 60fps means NTSC with pedestal 7 5IRE will be used o 2bfps and 50fps means PAL will be used o Other detected standards including 23 98fps and 24fps will use PAL colour space conversion when in auto mode 13 eyeheight Unit 34 Park House Watford Bus
9. 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 63 Back Pressing the button takes you to the previous level of menus Go To Menus 44 47 Menus 64 67 YCC CC high clip and knee Menu Num m Heading Function YCC C high clip This menu adjusts the high YCC chroma clip value Values are in percent YCC C high knee This menu adjusts the high YCC chroma knee value Values are in EE 08 ax the button takes you to the previous level of menus Go To Menus 60 63 Menus 68 71 YCC CC low clip and knee Menu Num m Heading Heading Funcdion YCC C low clip This menu adjusts the low YCC chroma clip value Values are in percent YCC C low knee This menu adjusts the low YCC chroma knee value Values are in percent 70 71 Back Pressing the button takes you to the previous level of menus Go To Menus 60 63 38 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 72 75 Composite clipping main menu Menu Num Heading Function 72 Component luma Pressing the button takes you to the setup Component luma menu Go To Menus 76 79 73 Component chroma Pressing the button takes you to the setup Component chroma menu Go To Menus 88 91 74 75 Back Pressing the butto
10. previous level of menus Go To Menus 188 191 Menus 200 203 Software upgrade in progress info menu Menu Num Heading Function 200 gt 201 ze eem 202 203 Menus 204 207 Proc amp gain NTSC IRE Menu Num Heading Function 54 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 204 Luma gain This menu adjusts the luma gain adjustment between 0 and 200 205 Chroma gain This menu adjusts the chroma gain adjustment between 0 and 200 206 Black lift This menu adjusts the black lift between 30 0 IRE and 30 0 IRE 207 Back Pressing the button takes you to the previous level of menus Go To Menus 16 19 Menus 208 211 Ring suppression RGB percentage Menu Num Heading Function Ring suppression This menu cycles the Ring status suppression between off on and 208 auto For more information on the ring suppression Go To 3 3 1 209 Ring suppression This menu sets the value for the high high clip clip limit of the ring suppression Values are in percent 210 Ring suppression This menu sets the value for the low low clip clip limit of the ring suppression Values are in percent 211 Back Pressing the button takes you to the previous level of menus Go To Menus 100 103 Menus 212 215 Ring suppression PAL mV
11. 0 2 100 200 400 4 R A 96 96 w 11 N A N A 5 N A BACK A prev 11 Gr N A N A 6 N A A 11 Gr N A N A 7 N A A 11 H H N A N A 8 N A A 11 Gr N A N A 9 N A A 12 Gr N A N A 0 N A A 12 Gr N A N A 1 N A A 12 Gr N A N A 2 N A A 12 Gr N A N A 3 N A A 12 Log M 0 1 4 R Mode A Of On w f 66 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 12 Log 0 102 5 R Thresh 3 A w 12 H H N A N A 6 N A A 12 Gr N A N A 7 N A A 12 ATC 0 2 8 R Mode A T VI W C TC2 12 Time 0 2 9 R Code A A zT VI w TC C TC 13 1 312 0 R VITCLn L1 A w 13 L2 1 312 0 R B W 13 Gr N A N A 1 N A A 13 HiCompHY 140 2 R clip Vari 0 A W able 13 HiComp Y 140 3 R knee I Vari O A Ww able 13 H HM N A N A 4 N A A 13 Gr N A N A 5 N A A 13 LoComp Y 651 6 R clip 36 Vari A W able 13 LoComp Y 651 7 R knee I 36 Vari A W able 13 H HM N A N A 8 N A A 13 Gr N A N A 9 N A A 14 HiComp C 140 0 R clip Vari 0 A W able 14 HiComp C
12. 100 email eyesales eyeheight com processing 13 Loudness Channels Pressing the button takes you to the menu Peak Loudness menu Go To Menus 244 247 14 Limits menu Pressing the button takes you to the Limits menu Go To Menus 176 179 15 Back Pressing the button takes you to the previous level of menus Go To Menus 120 123 Menus 16 19 Proc amp main menu Menu Num Heading Function 16 Proc amp status Pressing this button turns on or off the proc amp 17 Hue menu Pressing this button takes you to the hue menus Go To Menus 20 23 18 Gain menu Pressing this button takes you to the gain menus Go To Menus 24 27 19 Back Pressing the button takes you to the previous level of menus Go To Menus 04 07 Menus 20 23 Proc amp hue Menu Num Heading Function 20 Hue adjustment This button sets the value of the hue adjustment with a range of 180 to 180 degrees 23 Back Pressing the button takes you to the previous level of menus Go To Menus 16 19 33 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 24 27 Proc amp gain PAL mV Menu Num Heading Function 24 Luma gain This menu adjusts the luma gain adjustment between 0 and 200 25 Chroma gain This menu adjusts the chroma gain adjustment between 0 and 200 26 Black lift This menu adjus
13. 2 6 R Supprn A OF AUT M w F O AN L 21 High Clip 140 7 R Vari 0 A Ww able 21 Low MClip 651 8 R 36 Vari A Ww able 21 Gr N A N A 9 N A A 22 MonOP 0 3 0 R A Soli Flas Flas Zee w d h h bra 22 RD 4 0 3 1 2 0 B Ton Ton e e 22 Keyed 0 102 1 R MGain 3 A W 22 Colour s 0 3 1 Whte 2 R A 1 1 G 1 Bl w Re rn ue d 22 G 0 3 2 Whte 2 R B 2 2 0 2 BI w Re rn ue d 22 Gr N A N A 3 N A A 22 0 1 4 R Output Link A Sin Dua w M o gle 22 RD Out 1 0 2 5 A Leg Raw Indi al ct 70 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 22 0 2 5 R B w 22 RD Out 2 0 2 6 A Leg Raw Indi al ct 22 0 2 6 R B 22 N A 7 N A next BAC A Ky 22 OP 0 1 12b 8 R Bit Depth A 10b w 22 OP 0 2 100 200 400 9 R Dyn Rnge A 96 96 w 23 M M N A N A 0 N A A 23 Gr N A N A 1 N A A 23 Video 0 1 2 R BInkng A Off On w 23 0 3 R BInkng T Vari A W able 23 B 0 3 R Vari B W able
14. 23 0 4 R Blnkng L Vari A W able 23 R 0 4 R Vai B W able 23 N A N A 5 N A BACK A rev 23 N A 6 N A PLEASE A 23 N A 7 N A INPUT 4 A 23 N A 8 N A VIDEO A 23 N A 9 N A SIGNAL A 24 PkClip 654 0 0 R 76 A w 24 PkKnee 654 0 1 R 76 A Ww 24 Peak 10 999 2 R Comprs A Ww 1 24 Gr N A N A 3 N A A 24 0 5 4 R Chanel Pre A S3 S32 S32 S32 Ste Custo w set 20 3mA 3mB 3m reo m C 24 L 0 16 5 R A w 24 C254 0 16 5 R B Ww 7l eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 24 R 0 16 5 R C w 24 Ls 0 16 6 R A w 24 Rs 0 16 6 R B w 24 LF 0 16 6 R GC w 24 Gr N A N A 7 N A A 24 Attack 4t 0 12 0 2 05 1 2 3 6 8 R A 1 1 2 3 3 4 4 w 2 8 4 016 1218 24 Decay 0 12 02 05 1 2 3 6 1 1 2 3 3 4 4 9 R A 2 8 4 016 21 8 w 25 Window 1 200 0 IR S A w 25 Gr N A N A 1 N A A a a a 5 4 Technical Specification 5 4 1 Description Provides legalisation of the SD Standard Definition version SD HD Multi rate version or dual link 4 4 4 Dual Link version input s
15. 30 50 59 84 60 Dual Link 4 4 4 1080i 23 98psf 24psf 23 98p 24p 25p 50i 29 97p 30p 59 94i 60i 720p 23 98 24 25 29 97 30 50 59 84 60 73 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com
16. N A N A N A A 90 M MK N A N A N A A 91 Gr N A N A N A A 92 HiComp C 986 R clip mV Vari A W able 93 HiComp C 986 R knee Vari A w mV able 94 M H N A N A N A A 95 Gr N A N A N A A 96 LoComp C 652 R clip mV 36 Vari A Ww able 97 LoComp C 652 R knee 4 36 Vari A w mV able 98 M H N A N A N A A 65 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 99 Gr N A N A N A A 10 Domain 0 3 0 R A AU PAL NTS NTS w TO C C 10 RD 0 3 0 0 B IRE 7 51 RE 10 Gr N A N A 1 N A A 10 Gr N A N A 2 N A A 10 Gr N A N A 3 N A A 10 Gr N A N A 4 N A A 10 Gr N A N A 5 N A A 10 H H N A N A 6 N A A 10 Gr N A N A 7 N A A 10 Mode 0 1 8 R A Ma SM w nua PTE l 10 RD 0 1 352 8 B 10 Link 0 1 9 R A Sin Dua Ww gle 10 RD 0 3 A B 9 B Swa Only Only ppd 11 RD 0 409 0 Resltn H 5 A 11 RD V 0 409 0 5 B 11 N A N A 1 N A next BAC A Ku 11 0 1 2 R Colour Mo A YC RG W de bCr B 11 Bit 0 1 12b 3 R Depth A 10b W 11 D Rnge
17. Options are Legal Raw or Indicate If the output video link mode is set to dual link this menu will be automatically set to the same as output 1 Pressing the button takes you to the previous level of menus Go To Menus 116 119 Back x 227 57 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menu Num 228 229 230 231 Menus 232 235 Blanking menu Menu Num 232 233 233 234 234 235 Menus 228 231 Configure outputs menu 2 2 Heading Output video bit depth Output video dynamic range Heading Blanking status Top Bottom Left Right Back Function This menu sets the output video bit depth to either 10 or 12 bit This menu sets the output video dynamic range to 100 200 or 400 Pressing the button takes you to the previous level of menus Go To Menus 116 119 Function This menu the video blanking to On or Off See section 3 3 2 for more information This menu sets the number of lines that are blanked from the top of the picture See section 3 3 2 for more information This menu sets the number of lines that are blanked from the top of the picture See section 3 3 2 for more information This menu sets the numb
18. a full description of its usage M Text Up en Acc Low L Txt Txt2 Txt4 Txt T T T T Txt10 u ess e 1 5 xt xt xt xt V 6 7 8 9 0 RD Legalr 0 1 50 HD 0 RD 4 0 5 525 625 720 10 B Vid 80 Custo m 1 0 4 Gr Gr Gr R A Gr Gr W 2 RD Mem 0 14 A 6e eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 3 Gr N A N A N A A 4 Gr N A N A N A A 5 Gr N A N A N A A 6 Gr N A N A N A A 7 N A N A next BAC A Ky 8 Gr N A N A N A A 9 Gr N A N A N A A 10 Gr N A N A N A A 11 N A N A N A BACK A prev 12 KARMA 0 1 R Audio A Dis Ena Ww abl ble 13 Gr N A N A N A A 14 N A N A Limits A 15 Gr N A N A N A A 16 0 1 Gr R A Gr W 17 Gr N A N A N A A 18 Gr N A N A N A A 19 Gr N A N A N A A 20 Hue 653 180 R Degree 56 A w 21 M MK N A N A N A A 22 M M N A N A N A A 23 Gr N A N A N A A 24 Luma 0 200 R MGain 0 A w 25 0 200 R Chro
19. menu toggles the input video mode between manual and SMPTE 352 For more information Go To 3 2 6 109 Input video link type Switches the link mode to either Single link or dual link mode For more information on dual link Go To 3 2 6 110 Input video This is a display of the input video resolution resolution as detected by the LE 2 Display is of visible lines pixels not the total number of lines pixels 111 Back Pressing the button takes you to the previous level of menus Go To Menus 104 107 Pressing the next button on the panel will take you to the next menu in the nested menu sequence Go To Menus 112 115 Menus 112 115 Input details menu 2 2 Menu Num Heading Function 112 Input video colour This menu toggles the input video mode colour mode between YCbCr and RGB 113 Input video bit depth This menu toggles the input video bit depth between 10 and 12 bit 114 Input video dynamic This menu cycles the input video range dynamic range between 10096 20096 and 400 115 Back Pressing the button takes you to the previous level of menus Go To Menus 104 107 Pressing the prev button on the panel will take you to the previous menu in the nested menu sequence Go To Menus 108 111 43 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford
20. of indicate display type out indication between solid 1 colour flash 2 colour flash and 2 colour zebra mode 56 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com For more information on the indicate output settings Go To 3 2 7 This menu sets the gain for the indicate output A higher number makes each illegal pixel a more solid colour whereas a low number makes the indicate output more of a gradual shading of illegal areas of the picture Indicate output gain Indicate output This menu sets the colours for the colours indicate output Colour 2 is only used in 2 colour flash and zebra modes 221 222 223 Back Pressing the button takes you to the previous level of menus Go To Menus 116 119 Menus 224 227 Configure outputs menu 1 2 Menu Num Heading Function 224 Output video link This menu toggles the output video mode mode between single and dual link For more information on the output video settings Go To 3 2 7 225 Output 1 type This menu sets the type of output video to be present on output 1 of the i o card Options are Legal Raw or Indicate 226 Output 2 type This menu sets the type of output video to be present on output 2 of the i o card
21. 0 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 172 175 User memories menu 4 4 Menu Num Heading Function 172 Save user memory 4 Pressing this button saves the current unit settings to user memory 4 For details on the user memories see section 3 4 3 173 Save user memory 5 Pressing this button saves the current unit settings to user memory 5 174 Save user memory 6 Pressing this button saves the current unit settings to user memory 6 Pressing the button takes you to the previous level of menus Go To Menus 148 151 175 Back Pressing the prev button on the panel will take you to the previous menu in the nested menu sequence Go To Menus 168 171 Menus 176 179 KARMAudioRT Limits menu this menu is only operational with the KARMAudioRT option K Mens Num s Function 176 177 Loudness Menus Pressing the button takes you to the Loudness processing menus Go To Menus 248 251 Peak Menus Pressing the button takes you to the Peak processing menus Go To Menus 240 243 179 Back Pressing the button takes you to the Si eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH
22. 140 1 R knee I Vari 0 A Ww able 14 H HM N A N A 2 N A A 14 Gr N A N A 3 N A A 14 LoComp C 651 4 R clip 4 36 Vari A w able 14 LoComp C 651 5 R knee 36 Vari A Ww able 14 H H N A N A 6 N A A 14 Gr N A N A 7 N A A 14 Gr N A N A 8 N A A 14 Gr N A N A 9 N A A 15 H HM N A N A 0 N A A 15 Gr N A N A 1 N A A 15 PAL 0 1 2 R NORMAL A PS PS Ww T4 T4 15 NTSC 0 1 3 R NORMAL A PS PS 67 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com W T5 T5 15 BYpass 0 1 4 R All A PS PS WwW T6 T6 15 N A N A 5 N A next BAC A Ky 1 15 0 100 0 1 6 R RGB A PS PS Ww T1 1 15 0 1 R EBU103 Ti A PS PS Ww ght T2 T2 15 0 1 R EBU103 O A PS PS W ptim T3 T3 15 N A N A N A BACK A prev 16 96 M 0 1 0 R A Re DO w call NE 16 5 M 0 1 1 R A Re DO w cal NE 16 5 M 0 1 2 R A Re DO WwW call NE 16 N A N A N A next BAC A Ky 16 gt 0 1 4 R A Re DO WwW call NE 16 250 H 0 1 5 R A Re DO Ww cal NE 16 gt lt M 0 1 6 R A Re DO
23. 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Figure 1 L 2U Processing card Figure 2 6 55 and L eM Processing card l 2 Associated Equipment for the Le e The L 2 processing card requires the following in order to set up and operate the unit 1 An etherbox chassis FB 9E Up to six L 2 units and be installed in one chassis 2 A Flexipanel control surface such as an FP 9 or an FP 10 etherBox bu eueheight Figure 3 Front view of etherbox FB 9E fitted with FF 9 blank panel 7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com IN OUT OUT OUT IN RS232 LTC IB e GPI Figure 5 FP 9 Flexipanel can be fitted on the FB 9E or remotely using and RR 9 kit 8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com e Installation This unit requires HD SDI or SD SDI digital video connections to the BNC connectors Optionally RS232 GPI s and LTC may also be connected normally using CAT5e or better cable The user should refer to the etherbox user manual for installation of the L into a chassis and connection of flexipanels This will also describe the pr
24. 4 R Knee 68 Vari A w able 58 M M N A N A N A A 59 Gr N A N A N A A 60 Gr N A N A N A A 61 Gr N A N A N A A 62 M M N A N A N A A 63 Gr N A N A N A A 64 Hi YCCHC 106 R clip Vari 3 A WwW able 65 Hi YCCHC 106 R knee Vari 3 A W able 66 M MK N A N A N A A 64 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 67 Gr N A N A N A A 68 Lo YCC C 654 R clip f 96 69 Vari A w able 69 Lo YCCHC 654 181 R knee 90 69 5 A w 70 M M N A N A N A A 71 Gr N A N A N A A 72 Gr N A N A N A A 73 Gr N A N A N A A 74 H HM N A N A N A A 75 Gr N A N A N A A 76 Gr N A N A N A A 77 Gr N A N A N A A 78 M M N A N A N A A 79 Gr N A N A N A A 80 HiComp Y 986 R clip mV Vari A W able 81 HiComp Y 986 R knee Vari A mV able 82 M MK N A N A N A A 83 Gr N A N A N A A 84 LoComp Y 652 R clip 4 mV 36 Vari A W able 85 LoComp Y 652 R knee 36 Vari A w mV able 86 M M N A N A N A A 87 Gr N A N A N A A 88 Gr N A N A N A A 89 Gr
25. 9 Menus 136 139 Comp Y low clip and knee NTSC IRE Menu Num Num Heading Function 136 Comp Y low clip This menu adjusts the low Comp luma clip value Values are in IRE Comp Y low knee This menu adjusts the low Comp luma clip knee value Values are in E C 188 139 o button takes youto ihe the button takes you to the previous level of menus Go To Menus 76 79 Menus 140 143 Comp C high clip and knee NTSC IRE Menu Num Heading Funcion a 140 Comp C high clip This menu adjusts the high Comp component clip value Values are in IRE 46 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 141 Comp C high knee 142 143 Back Menu Num Heading 144 Comp C low clip 145 Comp C low knee 146 147 Back Menus 148 151 Memories menu Menus 144 147 Comp C low clip and knee NTSC IRE This menu adjusts the high Comp component clip knee value Values are in IRE Pressing the button takes you to the previous level of menus Go To Menus 88 91 Function This menu adjusts the low Comp component clip value Values are in IRE This menu adjusts the low Comp component clip knee value Values are in IRE Pressing the button takes you to the previous level of menus Go To Menus 88 91 Menu Num Heading 148
26. FP 9 controls 11 Figure 9 Types of menus showing their characteristic colours 11 Figure 10 Basic Legaliser Structure 12 Figure 11 RGB Legaliser Structure avete ide 15 Figure 12 YCC Legaliser SITUGILIEO ee repr tone Ene pere bn tsub dea bona tien bbs ciunt 15 Figure 13 Composite Legaliser 16 Figure 14 Illegal Source r 17 Figure 15 Hard Clipped Output iiiiieuieiii te ortae rennen rne aeree neuen nine 17 Figure 16 Soft Clipped tun dec usdunq stan Tene uide 18 Figure 17 Logging Application GUI ree depen Minne 25 25 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com System Overview This manual describes the function of the LE 2 The Le e is a geNETics processing card which fits into a single slot of the eyeheight etherbox FB 9E This manual must be used in conjunction with the etherbox manual which contains much of the generic information
27. Go To Menus 88 91 Al eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 100 103 Component main menu Menu Num Heading Function 100 Legaliser domain This menu sets the domain used by the legaliser For more information Go To 3 2 3 101 Comp setup Pressing the button takes you to the Comp settings menu Go To Menus 72 75 102 Ring suppression Pressing the button takes you to the setup ring suppression settings menu Go To Menus 208 211 103 Back Pressing the button takes you to the previous level of menus Go To Menus 04 07 Menus 104 107 Input output menu Menu Num Heading Function 104 Input video setup Pressing the button takes you to the input video settings menu Go To Menus 108 111 105 Output video setup Pressing the button takes you to the output video settings menu Go To Menus 116 119 106 m 107 Back Pressing the button takes you to the previous level of menus Go To Menus 08 11 Menus 108 111 Input details menu 1 2 42 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menu Num Heading Function 108 Input mode This
28. Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 116 119 Output menu Menu Num Heading 116 Output video config 117 Output video monitor settings 118 119 Back Menus 120 123 Utilities menu Function Pressing the button takes you to the output video configuration settings menu Go To Menus 224 227 Pressing the button takes you to the output video monitor settings Go To Menus 220 223 Pressing the button takes you to the previous level of menus Go To Menus 104 107 Menu Num Heading 120 Log mode settings 121 Time code settings 122 Blanking settings 123 KARMAudioRT audio processing settings Function Pressing the button takes you to the logging setup menu Go To Menus 124 127 Pressing the button takes you to the time code setup menu Go To Menus 128 131 Pressing the button takes you to the blanking setup menu Go To Menus 232 235 Pressing the button takes you to the KARMAudioRT setup menu Go To Menus 12 15 these menus are only operational with the KARMAudioRT option K 44 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 124 127 Data logger menu Menu Num Heading Function 124 Log mode enable This menu enables or disables
29. Preset memories 149 User memories 150 151 Back Function Pressing the button takes you to the preset memory loading menus Go To Menus 152 155 Pressing the button takes you to the user memory load and save menus Go To Menus 160 163 Pressing the button takes you to the previous level of menus Go To Menus 00 03 47 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 152 155 Preset memories menu 1 2 Menu Num Num Heading Function 152 Load preset 1 Pressing this button loads the PAL normal preset memory For details on the preset memories see section 3 4 2 Load preset 2 Pressing this button loads the NTSC normal preset memory 154 Load preset 3 Pressing this button loads the Bypass all preset memory 155 Back Pressing the button takes you to the previous level of menus Go To Menus 156 159 Preset memories menu 2 2 Menus 148 151 Pressing the next button on the panel will take you to the next menu in the nested menu sequence Go To Menus 156 159 Menu Num Heading Funcion ti 156 Load preset 4 Pressing this button loads the PAL normal preset memory For details on the preset memories see section 3 4 2 Load preset 5 Pressing this button loads the PAL normal preset memory
30. Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com previous level of menus Go To Menus 12 15 Pressing the prev button on the panel will take you to the previous menu in the nested menu sequence Go To Menus 0 3 Menus 180 183 System menu Menu Num Heading Function 180 Memories menu Pressing the button takes you to the memories menu Go To Menus 148 151 181 Versions menu Pressing the button takes you to the versions menu which includes the software upgrade menu Go To Menus 184 187 182 Resets menu Pressing the button takes you to the unit resets menu Go To Menus 188 191 183 Back Pressing the button takes you to the previous level of menus Go To Menus 08 11 Menus 184 187 Software menu Menu Num Heading Function 184 L 2 version number This menu displays the version number of the LE 2 185 186 Upgrade software Pressing the button takes you to the menu upgrade software menu Go To Menus 192 195 187 Back Pressing the button takes you to the previous level of menus Go To Menus 180 183 52 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 188 191 Resets menu Menu Num Heading Function 188 Reboot unit Pressing this will reset the LE 2 The unit should finish rebo
31. Resetting the L There are 2 types of resets available which don t involve removing the LE 2 from the chassis Both of these are available from the following menu navigated to via Setup System Resets Menus 188 191 Resets menu The reboot this unit option will have the same effect as removing power to the LE 2 without having to have physical access to the unit If the unit exhibits unusual behaviour this is a good action to take and may correct the problem It is likely however that output video will be slightly interrupted as the unit resets so doing this while on air is not recommended The factory reset option will display the following menu Menus 196 199 Factory reset menu 59 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Pressing YES will restore all the factory default settings and will clear all the memories WARNING Performing a factory reset will permanently erase all user memories that have been stored as well as erasing the current power on default setting 3 8 Software upgrade Navigate to the following menu under Setup System Ver ns Pressing UPGRDE SOFTWR NOW will display the following set of menus Pressing YES will display the following set of menus The unit will be set into the state where it can be field upgra
32. WwW call NE 16 N A N A 7 N A next BAC A K prev 16 96 M 0 1 8 R A Sav DO w e NE 16 5 M 0 1 9 R A Sav DO w e NE 17 96 M 0 1 0 R A Sav DO Ww e NE 17 N A N A N A next BAC A K prev 17 gt H 0 1 2 R A Sav DO Ww e NE 17 26 gt 0 H 0 1 3 R A Sav DO Ww e NE 17 gt lt M 0 1 4 R A Sav DO WwW e NE 17 N A N A 5 N A BACK A prev 17 Limit 654 10 6 R 56 A Ww 17 Gr N A N A 7 N A A 17 Gr N A N A 68 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 8 N A A 17 Gr N A N A 9 N A A 18 Gr N A N A 0 N A A 18 Gr N A N A 1 N A A 18 Gr N A N A 2 N A A 18 Gr N A N A 3 N A A 18 i H M N A N A 4 N A A 18 H H N A N A 5 N A A 18 N A N A 6 N A Upgrde Sof A twr Now 18 Gr N A N A 7 N A A 18 0 1 8 R A Re Plea w boo se t 18 RD 4 0 1 8 B this wait 18 RD 4 0 1 8 C unit 18 N A N A 9 N A Factry rese A tH 19 H HM N A N A 0 N A A 19 Gr N A N A
33. a iaia 11 3 1 2 Menu a 11 3 1 3 Parameter adjustment of a green 6 12 3 1 4 Parameter adjustment of a red menu 12 3 1 5 Information display a 12 sour peploii dbzrcae t 12 3 2 1 le cis asas kosa shasqa 12 3 2 2 Selecting the legalisation type 13 3 2 3 Setting the legaliser domain 13 3 2 4 Selecting the legaliser values 14 3 2 5 Prog AMP M E 18 3 2 6 Setting up the input video parameters Dual Link units only 19 3 2 7 Setting up the output video 20 3 2 8 Recalling settings when video standard is changed 21 3 3 Advanced features of the LE 2 21 21 3 3 2 Adjusting the input picture blanking 22 3 3 3 KARMAudioRT Legalisation OPTIONAL LICENSABLE EXTRA 22 3 3 4 24 3 3 5 Setting up timecode extraction 25 34 Lu mH E
34. adjust the parameter in the respective LCD window A B C or D The direction and speed of rotation enable numeric values to be set easily 3 1 4 Parameter adjustment of a red menu A red menu is one in which there is two or three adjustable parameters In this case it is necessary to first select the menu by pressing the red button When the red button is pressed it will turn green and either two or three of the rotary digipot LEDS will flash indicating that the respective rotary digipot will operate the respective parameter 3 1 5 Information display A Yellow menu Which on most panels does look a light orange is one in which only information is displayed An example of this is the software version display 3 2 Setting up the L A Block diagram of the legaliser is shown in Figure 10 Each section is discussed below Video In AE Legaliser y Legal Out Monitoring Output Monitoring Out Generation Figure 10 Basic Legaliser Structure 3 2 1 Legaliser The legaliser operates in one of three modes RGB YCC component or Composite The mode is selected via the top level mode menu Each mode is discussed below In all modes the legaliser is transparent to pixels within the legal range le eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com
35. al link If using SMPTE 352 in dual link mode this will also indicate if only one of the two inputs is present or if the input video streams have been connected to the Le e the wrong way around Resoln indicates on all versions This indicates the resolution of the input video as detected by the LE 2 Colour mode This selects the input video colour mode as either YCbCr or RGB Bit depth This sets the input video bit depth to either 10 or 12 bit 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com D Rnge This sets the dynamic range of the input video to 100 200 or 400 3 2 7 Setting up the output video parameters Either output of the L 2 can be configured as an indicate output which allows the user to see which parts of the picture are being processed by the legaliser The output config menu allows you to set the type of signal present at the output BNC s and the output monitor menu allows the indicate output settings to be customised including solid flashing Zebra indication modes colour choice and intensity level To set up the output video settings navigate to Setup In Out Output Config Menus 224 227 Configure outputs menu 1 2 Menus 228 231 Configure outputs menu 2 2 If using the LE 2 in dual link mode Dual Link units only outputs 1 and 2 c
36. and then press enter A padlock symbol will appear on the menu and it cannot be adjusted To unlock menu 5 type A05 as step 2 above Other menus are done in the same way To lock the whole product type L as step 2 above and to unlock the whole product type A as step 2 above 3 5 1 Globally locking the user menus Hold in the DEVICE SELECT button to which the LE 2 is assigned until a message is displayed on the menus informing you that User has LOCKED menus or User has UNLOCKED menus ea eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 3 6 GPI Tally Set up 3 6 1 On Board GPI s The LE 2 is a geNETics product The geNETics system uses generic Input Output cards which have 2 GPI s These GPI s activate the first 2 user memories in the system GPI 1 Activate User Memory 1 GPI 2 Activate User Memory 2 Activate Short to ground or logic OV See Appendix 3 6 2 Configuring tallies on the etherbox The LE 2 can use an etherbox tally to indicate that it is is bypass no processing mode The etherbox chassis has three usable tallies These are Tallies 11 12 and 13 Set up menu 121 for the box number and tally number that you wish to use If you do not wish to use a tally set the box number to 0 Refer to the etherbox manual for interface information 3 7
37. annot be set independently so any changes to the outputs will be automatically made to both The output modes can be set to the following Legal output is the legalised video stream e Raw output is the raw unaltered input video stream e Indicate output is the legalised video stream but with the illegal parts of the video stream coloured according to how the output monitor menu is set up The output monitor menu is shown below accessed by going to Setup In Out Output gt Monitor 20 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 220 223 Monitor output menu When using an indicate output the selected colour is keyed over the legal output with the opacity of the colour indicating how illegal the area is Because signals are typically only slightly illegal the gain on the keyer can be controlled to deliver the desired mix The gain is controlled by the Keyed Gain menu and setting this menu to its maximum value will give the same output as a traditional indicate output 3 9 8 Recalling settings uihen video standard is changed When the menu settings are changed the new values are automatically backed up to non volatile memory When the video standard is changed the previous settings for that standard are automatically restored 3 3 Advanced features of
38. arameters the menu windows Figure 8 Flexipanel FP 9 controls 3 1 1 Device Buttons There are 8 grey device buttons These switch between the currently selected processing cards installed in the etherbox It is also possible to select cards in another chassis if the l Bus is connected to the other chassis 3 12 Menu Navigation There are two ways to navigate from menu to menu 1 Using the NEXT and PREV buttons These are for Flat menu structures The NEXT and PREV LEDS will flash while further menus are available 2 Using a GOTO ANOTHER MENU LCD button as below coloured orange This is more common and will take you straight to a relevant set of menus Examples are the Play and UTILS menu s shown on Figure 8 Figure 9 Types of menus showing their characteristic colours Il eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 3 1 3 Parameter adjustment of a green menu A green menu is one in which there is only one adjustable parameter There are two ways to adjust the parameter in a green menu 1 Press the green LCD button This will increment the value in that window This is most frequently done when the menu parameter is Textural for example switching a parameter between ON and OFF In this case a button press is most natural 2 Use the Rotary digipot A B C or D to
39. common to all eyeheight geN Tics products The L 2 Product The Le 2 is a full featured legaliser system using the geN Tics platform The main features of the L e are as follows Available in Standard Definition Multi rate or Dual Link versions Provides Legalisation of the SD SDI input Standard Definition version SD HD SDI Input signal with full 10 bit processing throughout MultiDef version or 12 bit for dual link 4 4 4 Dual Link version Composite YCC Component and RGB colour spaces Two Independent SD HD SDI outputs each changeable between Legalised Raw and Indicate out Adjustable Clipping Levels Adjustable soft clipping knee levels Highly effective overshoot and undershoot suppression on the luminance signal Integral luma and chroma gain black level adjustment amp hue rotation EBU R103 standard legalisation settings 7 5 IRE or 0 IRE Pedestal 6 User Memories Log output with Time code and PC viewer programme Unique severity display mode on monitoring output 2 off On board GPI s for memory recall Compatible with etherbox GPI Tallies FULLY software and firmware updatable using Flash technology On Board simple text based RS232 automation protocol Compatible with eyeheight geN Tics automation protocol Mechanical relay bypass available NS eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923
40. ded using the Flasher software which can be downloaded from our web site www eyeheight com 30 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 4 The LE 2 Menu Set The following set of menus defines the operational controls of the Le a Note Only parameters with RED menu numbers are stored in the memories and are also saved automatically as soon as they are changed Menus 00 03 Top Level Menus Menu Num Heading Function 0 Legaliser standard This menu displays the current input video standard as detected by the Le e 1 Legaliser mode This menu selects the required legalisation mode between off RGB YCC comp or comp amp RGB 2 Loaded Memory Displays the currently loaded memory if any This will display no mem loaded upon any change to a loaded memory to indicate something has been changed 3 Setup Pressing this will take you to the first of the nested setup menus Go To Menus 04 07 Menus 04 07 Main menu set 1 2 Menu Num Heading Function 4 RGB YCC legal Pressing this button takes you to the menu RGB and YCC legalisation settings menus Go To Menus 28 31 5 Composite legal Pressing this button takes you to the menu Composite legalisation settings menu which includes the ring suppression Go To Menus 100 103 6 Proc amp menu Pressing this bu
41. e legaliser Link A outputs and Output 2 is the Link B output The RS232 GPI LTC connection pin outs are shown in the technical appendix at the end of this manual The RS232 connection can be connected to the COM port of a PC with the eyeheight Error Logging Application for QA Quality Assessment recording purposes The LTC connection will allow for accurate time code stamping for the QA The RS232 can alternatively be used to recall user memories and presets with a simple text based RS232 protocol Three GPI s can be used to recall user memories 1 and 2 respectively 10 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 3 Operation All GeNETics products are controlled using a generic menu system This generic menu system is operated from a generic panel Flexipanel FP 9 or FP 10 An FP 9 is shown below An FP 10 has the same controls in a different layout style For information about acquiring processor cards for control on a Flexipanel see the etherbox manual section 4 3 General Flexipanel controls Device Buttons with LEDS are used to Switch from one t processing card to NEXT menu Button eyeheight Keyboard Menu Wind Buton lenu Windows Button Connector A B C D display 4 AE TED menus ata Aon These are used to ach menu can have change parameters in up to 3 p
42. e of the picture e By default all blanking variables are set to zero e Video Blanking defaults to Off 3 3 3 KARMAudioRT Loudness and true peak control these menus are only operational uiith the KARMAudioRT option K KARMAudioRT provides real time automatic control of peak multi channel embedded audio loudness as measured using then ITU R BS 1770 multi channel loudness algorithm KARMAudioRT also provides real time per channel true peak limiting as measured by the ITU R BS 1770 true peak estimation algorithm In order to control peak loudness KARMAudioRT continually calculates the multi channel short term loudness and compares this to the loudness limit If the loudness limit is exceeded the audio gain for all channels selected for KARMAudioRT reduces at the rate set in the loudness attack menu until the short term multi channel loudness falls below the defined limit While the short term multi channel loudness is below the defined limit the audio gain will increase to a maximum of unity at the rate defined by the loudness decay menu KARMAudioRT will never apply a gain greater than unity to the audio After the loudness control stage each audio channel is analyzed individually for true peak limiting Where the estimated true peak value of a channel exceeds the Peak Knee value the source audio is adjusted according to the Clip and the Peak Compression to restrict the true peak value to fall between the Peak Knee and Peak Clip values B
43. er of pixels that are blanked from the left of the picture See section 3 3 2 for more information This menu sets the number of pixels that are blanked from the right of the picture See section 3 3 2 for more information Pressing the button takes you to the previous level of menus Go To 58 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 120 123 Menus 240 243 KARMAudioRT Peak processing menu this menu is only operational with the KARMAudioRT option K Menu Num Heading Function 240 Peak Clip This menu sets the level at which the audio peaks are clipped at in dBTP 241 Peak Knee This menu sets the level at which the audio peaks start to be adjusted as per the gradient in menu 242 in dBTP 242 Peak Compression This menu sets the ratio of the slope at which the peak is reduced by after the knee level has been reached in dBTP 243 Back Pressing the button takes you to the previous level of menus Go To Menus 176 179 Menus 244 247 KARMAudioRT Channels this menu is only operational with the KARMAudioRT option K Menu Num Heading Function 244 245 L C R Chanel Sets the embedded audio channel Numbers numbers for channels Left Centre and Right Setting 0 disables that channel in the loudness calculation and true peak correction
44. eyeheight com 5 Technical Appendix 5 GPIi Tally RS23e2 technical information The Processor card has an RJ 45 connector with GPI Tally and RS232 connections as shown below 1 GPI 1 White Orange 2 Not Used Orange 3 GPI 2 White Green 4 GND Blue 5 RS232 TX White Blue 6 RS232RX _ Green 7 LTC White Brown 8 LTC Brown Table 1 GPI LTC and RS232 pin out on RJ 45 5 1 1 RS23e Interface This loosely follows the pin convention of EIA 561 which is a standard for RS232 on an RJ45 cable Only TX RX and Signal ground pin 4 are implemented For the Le e the following RS232 parameters apply e 115Kbaud 8 Bits no parity 1 Stop bit 5 12 LTC Linear Time code Interface This unit takes in standard balanced LTC at 10dB to 10dB level The user can ground the LTC side for unbalanced use just using ground and the LTC This interface is only designed for LTC at unity play speed and will not track fast shuttling timecode 5 2 On Board automation protocol 5 e l Implimentation on RSe3e A simple text based protocol has been implemented on the RS232 interface All text strings are shown in inverted commas do not include them in the actual command sent Each byte within a text string must be sent within 10mS of each other or the command will time out This on board protocol is not the same as the geNETics protocol Refer to the geN Tics protocol in section 6 Product 6el eyeheight Unit 34 Park House Watford Busine
45. ford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com If timecode data is present in the input video it can be extracted for use with the logging software to give a precise view of exactly where illegal video is Setup of the timecode extraction is done from the below menu found under Setup Utils gt T Codes Menus 128 131 Time code menu To set up timecode extraction select the timecode type from VITC LTC or ATC and if necessary select the ATC mode or VITC line numbers to further specify where the timecode data should be extracted from When this data is specified correctly the next time the logging application is used it will log the legaliser data with timecode data 3 4 Memories 3 4 1 Power on memory On power up this product will automatically load the settings it had the last time it had power 3 4 2 Preset memories There are 6 preset memories which set the unit up with some common settings These are outlined below PAL normal e Legalisation method to Comp Ring suppression off Comp Y high clip and knee to 700mV Comp Y low clip and knee to OmV Comp C high clip and knee to 930mV Comp C low clip and knee to 230mV Comp domain to PAL NTSC normal e Legalisation method to Comp Ring suppression off Comp Y high clip and knee to 100 0 IRE Comp Y low clip and knee to 0 0 IRE Comp C high clip and knee to 120 0 IRE P6 eye
46. height Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com e Comp C low clip and knee to 33 0 IRE e Comp domain to NTSC 7 5 IRE Bypass All Legalisation method to off e Ring suppression off 0 100 RGB Legalisation method to RGB e RGB high clip and knee to 100 096 e RGB low clip and knee to 0 096 e Ring suppression off EBU103 Tight Legalisation method to RGB e RGB high clip and knee to 103 096 e RGB low clip and knee to 1 0 e Ring suppression off EBU103 Normal Legalisation method to RGB e RGB high clip and knee to 101 096 e RGB low clip and knee to 0 096 e Ring suppression off Please note that no settings other than those listed above are changed when loading these presets 3 4 3 User Memories The user memories are a generic feature of all eyeheight geNETics products The L 2 has six presets for common legalisation standards and six user memories which are initially named user Mem 1 through to user mem 6 To save to a user memory set up the unit as required and navigate to Setup System Mems USER Preset then save the settings from either of the menus shown below Menus 168 171 User memories menu 3 4 27 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone
47. ignal with full 10 bit processing throughout NOTE Indicate output is NOT available in dual link output mode 5 4 2 Features Composite YUV and RGB colour spaces and combined RGB composite with two independent outputs for Legalise and user controllable Legal Indicate Adjustable clipping levels and soft clipping knee levels Integral luma and chroma gain black level adjustment amp hue rotation EBU R 2003 standard SDI legalisation settings and 7 5 IRE or 0 IRE Pedestal with 6 user memories and common presets Log output with timecode and PC viewer programme Automation Port using simple protocol for presets memories Unique severity display mode on monitoring output Firmware and software fully updatable by file upload Mechanical relay bypass option available Optional web based java soft panel and specific web app available Not available on the MX 9 chassis 5 4 3 Formats Standard Definition version 625 50 525 59 94 72 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com e Multi rate version 625 50 525 59 94 1080i 23 98psf 24psf 23 98p 24p 25p 50i 29 97p 30p 59 94i 60i 720p 23 98 24 25 29 97 30 50 59 84 60 e Dual Link version Single Link 625 50 525 59 94 1080i 23 98psf 24psf 23 98p 24p 25p 50i 29 97p 30p 59 94i 60i 720p 23 98 24 25 29 97
48. iness Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com e NTSC with 7 5 IRE offset a k a pedestal The unit default mode is Auto The domain has an effect on a certain number of menus which will display either in mV or in IRE For a few menus different values are stored for each mode so for example switching from PAL to NTSC will switch to using the NTSC menus for those few variables rather than converting the PAL values into NTSC equivalents The values treated in this way are listed below e High Comp Y clip and knee Low Comp Y clip and knee High Comp C clip and knee Low Comp C clip and knee Proc amp gain black lift value Ring suppression high and low clip 3 2 4 Selecting the legaliser values RGB legalisation Setting the RGB legaliser values is done via the below menus which is found under Setup RGB YCC2 RGB Setup Menus 36 39 RGB high clip and knee The basic form of the RGB legaliser is shown in Figure 11 In RGB mode the legaliser first converts the video from the YCbCr colour space to the RGB colour space The RGB data is then soft clipped according to the settings for RGB High Clip amp Knee and RGB Low Clip amp Knee Finally the clipped RGB data is converted back to the YCbCr colour space The RGB legal colour space is a subset of the composite legal colour space so an RGB legal signal is also composite
49. legal but the reverse is not true l4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Soft Clip YCbCr G RGB t Sot Legal Out RGB Clip YCbCr L il Soft Clip Ganged Figure 11 RGB Legaliser Structure YCC Legalisation Setting the YCC legaliser values is done via the below menus which are found under Setup RGB YCC2 YCC Setup Menus 52 55 YCC high clip and knee The basic form of the YCC legaliser is shown in Figure 12 YCC Legaliser Structure In YCC mode the legaliser provides direct clipping of the raw YCbCr data using separate clip and knee parameters for the Y and colour difference components Soft Clip Cb Video In J99 Demux Soft Mux legal Out Clip L a f Soft Clip Ganged Figure 12 YCC Legaliser Structure Composite legalisation Setting the YCC legaliser values is done via the below menus which are found under Setup gt RGB YCC gt YCC Setup 5 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 80 83 Composite Y high clip and knee PAL mV The basic form of the composite legalise
50. lights and lowlights has been lost Figure 16 shows the same input signal legalised with a 1096 difference between the Clips and their respective Knees The highlight lowlight detail has been compressed into the legal region at the expense of some of the dynamic range of the originally legal part of the waveform l6 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 09 02 2006 17 48 05 L F2 351 914 Active Sample Ref INT Gain x1 00 M Mag x1 00 tA 1 4850 Gb s 1080i 50 00 R 3 000us div Waveform Mo Menu Parade R G B Filter Color Overlay Lowpass Space Figure 14 Illegal Source 09 02 2006 17 47 27 JF 2 351 914 Active Sample 0 CbY Act Ref INT Y Gain x1 00 Mag x1 00 tA 1 4850 Gb s 1080 50 00 3 000ns div Waveform wem Parade p Filter Overlay Lowpass Figure 15 Hard Clipped Output I7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com EN 10801 50 00 Waveform ilter ARTS Menu Filter Color Lowpass Space Figure 16 Soft Clipped Output 3 2 5 Proc Amp Setting the proc amp values is done from the following menu which i
51. logging mode For more information on the logging function of the L Go To Error Reference source not found Log threshold This menu sets the level at which an illegal pixel is considered a severe ee O 126 127 Wo Pressing the button takes you to the the button takes you to the previous level of menus Go To Menus 120 123 Menus 128 131 Time code menu Menu Num Heading Heading Function 128 ATC mode This menu sets the Ancillary time code mode between LTC VITC1 and VITC2 For more information on the time code function Go To 3 3 5 Time code mode This menu sets the time code mode to VITC LTC or ATC VITC line numbers This menu sets the VITC line numbers Back Pressing the button takes you to the previous level of menus Go To Menus 120 123 45 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 132 135 Comp Y high clip and knee NTSC IRE Menu Num Num Heading Function 132 Comp Y high clip This menu adjusts the high Comp luma clip value Values are in IRE Comp Y high knee This menu adjusts the high Comp luma clip knee value Values are in Eo 13 135 Wo Pressing the button takes youto the the button takes you to the previous level of menus Go To Menus 76 7
52. ma G 0 A WwW ain 90 26 Black 653 200 R Lift 36 A w mV 27 Gr N A N A N A A 28 Gr N A N A N A A 29 Gr N A N A N A A 30 M MK N A N A N A A 31 Gr N A N A N A A 32 Gr N A N A N A A 33 Gr N A N A N A A 34 M H N A N A N A A 63 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 35 Gr N A N A N A A 36 Hi 108 R RGB Clip Vari 7 A W 99 able 37 Hi 108 R RGB Knee Vari 7 A W 90 able 38 M MK N A N A N A A 39 Gr N A N A N A A 40 Lo 654 R RGB Clip 68 Vari A WwW 90 able 41 Lo 654 R RGB Knee 68 Vari A Ww able 42 H HM N A N A N A A 43 Gr N A N A N A A 44 Gr N A N A N A A 45 Gr N A N A N A A 46 M H N A N A N A A 47 Gr N A N A N A A 48 Gr N A N A N A A 49 Gr N A N A N A A 50 M M N A N A N A A 51 Gr N A N A N A A 52 Hi YCC Y 108 R Clip Vari 7 A W able 53 Hi YCC Y 108 R Knee Vari 7 A W 96 able 54 M M N A N A N A A 55 Gr N A N A N A A 56 Lo YCCHY 654 R Clip 96 68 Vari A w able 57 Lo YCCHY 65
53. ming video which are considered to be illegal and the GUI can be seen in Figure 17 The application also provides a visual indication of illegal green and severely illegal red pixels where a pixel is considered to be severely illegal if it is more illegal than the gamut threshold This enables the operator to isolate the dangerously illegal cases from those caused by minor variations between legaliser designs To start logging set up the COM port in the comms menu and then click start The logging operation can be suspended by hitting the stop button Where timecode is available to the unit in the format specified within the timecode menu of the L e the application will log data against the timecode If the timecode stops the log will also stop If no timecode is present the application will log continually The received section gives details of the last log entry received whilst clicking on the graph window brings up the cursor and populates the cursor section with the log entry relating the selected bar The zoom control allows viewing of a larger area of the log data Logs can be saved and opened at a later date using the file menu SEE Fie Log Comms Help 19 00 31 23 Received 5 858893 7 629726 19 00 29 00 Cursor 38 57205 43 34925 4 EN Buffer Size 1 Figure 17 Logging Application GUI 3 3 5 Setting up timecode extraction 25 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Wat
54. n takes you to the previous level of menus Go To Menus 100 103 Menus 76 79 Composite Y hi lo menu Menu Num Heading Function 76 Comp luma high clip Pressing the button takes you to the and knee setup Comp luma high clip and knee adjustment menu Go To Menus 80 83 77 Comp luma low clip Pressing the button takes you to the and knee setup Comp luma low clip and knee adjustment menu Go To Menus 84 87 78 79 Back Pressing the button takes you to the previous level of menus Go To Menus 72 75 Menus 80 83 Composite Y high clip and knee PAL mV 39 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menu Num Heading Function 80 Comp Y high clip This menu adjusts the high Comp luma clip value Values are in mV 81 Comp Y high knee This menu adjusts the high Comp luma clip knee value Values are in mV 82 83 Back Pressing the button takes you to the previous level of menus Go To Menus 76 79 Menus 84 87 Composite Y low clip and knee PAL mV Menu Num Heading Function Comp Y low clip This menu adjusts the low Comp luma clip value Values are in mV Comp Y low knee This menu adjusts the low Comp luma clip knee value Values are in mV Back Pressing the button takes you to the previous level of menus Go To Menus 76 79 Me
55. nus 88 91 Composite C hi lo menu Menu Num Heading Function 88 Comp composite Pressing the button takes you to the high clip and knee Comp composite high clip and knee setup adjustment menu Go To Menus 92 95 89 Comp composite low Pressing the button takes you to the clip and knee setup Comp composite low clip and knee adjustment menu Go To Menus 96 99 90 40 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 91 Back Pressing the button takes you to the previous level of menus Go To Menus 72 75 Menus 92 95 Composite C high clip and knee PAL mV Menu Num Heading Function 92 Comp C high clip This menu adjusts the high Comp component clip value Values are in mV 93 Comp C high knee This menu adjusts the high Comp component clip knee value Values are in mV 3 j e 95 Back Pressing the button takes you to the previous level of menus Go To Menus 88 91 Menus 96 99 Composite C low clip and knee PAL mV Menu Num Heading Function 96 Comp C low clip This menu adjusts the low Comp component clip value Values are in 97 Comp C low knee This menu adjusts the low Comp component clip knee value Values are in mV mV 98 99 Back Pressing the button takes you to the previous level of menus
56. ocess of acquiring a processing card in this case the by the Flexipanel which is necessary to access the menu structure within the L 9 2 1 Connections on the LE 2 product w op u g nu a 3 U Qa 2 r O GPI LTC RS232 i ae Figure 6 LE 2S or LE 2M connections The main video connections to the L 2S or LE 2M are shown above Outputs 1 and 2 are the legaliser outputs The Indicate output is configurable independently as either Legal Raw or Indicate outputs The RS232 GPI LTC connection pin outs are shown in the technical appendix at the end of this manual The RS232 connection can be connected to the COM port of a PC with the eyeheight Error Logging Application for QA Quality Assessment recording purposes The LTC connection will allow for accurate time code stamping for the QA The RS232 can alternatively be used to recall user memories and presets with a simple text based RS232 protocol Three GPI s can be used to recall user memories 1 and 2 respectively 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Output Output IB Output GPI LTC RSe32 Figure 7 L 8U connections The main video connections to the L 2U are shown above Input 1 is for Link A and Input 2 is for Link B Outputs 1 and 2 are th
57. oting within 30 seconds or so and it should have the same settings loaded as it had before the reset button was pressed 189 Factory reset Pressing the button takes you to the factory reset menu Go To Menus 196 199 190 191 Back Pressing the button takes you to the previous level of menus Go To Menus 180 183 Menus 192 195 Software upgrade menu Menu Num Heading Function 192 EE 193 194 Software upgrage Pressing this button will confirm you confirmation want to update the software of the LE 2 and will jump to the message displayed on Menus 200 203 The details of the update procedure can be found in section 3 8 195 Back Pressing the button takes you to the previous level of menus Go To Menus 184 187 53 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menus 196 199 Factory reset menu Menu Num Heading Function 196 197 198 Factory Reset Pressing this button will confirm you confirmation want to perform reset the LE 2 to its factory settings The menu icon will change to please wait while the action is performed WARNING Performing a factory reset will permanently erase all user memories that have been stored as well as erasing the current power on state 199 Back Pressing the button takes you to the
58. ou to the previous level of menus Go To Menus 32 35 Menus 40 43 RGB low clip and knee Heading Function This menu adjusts the low RGB clip value Values are in percent This menu adjusts the low RGB knee RGB low clip value Values are in percent k low knee DO o x Pressing the button takes you to the previous level of menus Go To Menus 32 35 35 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menu Num oum Menu Num Heading Menus 44 47 YCC clipping main menu Menu Num Heading Function 44 YCC luma setup Pressing the button takes you to the YCC luma menu Go To Menus 48 51 45 YCC chroma setup Pressing the button takes you to the YCC chroma menu Go To Menus 60 63 46 47 Back Pressing the button takes you to the previous level of menus Go To Menus 28 31 Menus 48 51 YCC Y hi lo menu Menu Num Heading Function 48 YCC luma high clip Pressing the button takes you to the and knee setup YCC luma high clip and knee adjustment menu Go To Menus 52 55 49 YCC luma low clip Pressing the button takes you to the and knee setup YCC luma low clip and knee adjustment menu Go To Menus 56 59 50 51 Back Pressing the button takes you to the previou
59. r is shown in Figure 13 Composite Legaliser StructureError Reference source not found In composite mode the legaliser restricts the Y Cb amp Cr components such that when the signal is converted to a composite waveform the Y component stays within the range allowed by the Y High Clip and Y Low Clip and the total composite waveform stays within the range defined by Comp High Clip and Comp Low Clip The legaliser works by selectively reducing the saturation of pixels which would otherwise result in over modulation of the composite waveform Composite mode preserves the hue of each pixel but not the saturation SU Clip Video In gt Demux CE 3 Mux P Legal Out Limiter Figure 13 Composite Legaliser Structure Comp RGB mode The video signal is legalised as described in the Composite legalisation section and then the legalised signal is passed through a second legaliser as specified in the RGB legalisation section Clip amp Knee Many of the legaliser functions present Clip and Knee parameters to the user The Clip parameters specify the maximum and minimum values the system legaliser will allow to pass Figure 14 shows an illegal input to the clipper with detail in the illegal highlight and lowlight areas of the signal When the knee values are set to the same value as their respective Clips the legaliser operates as a hard clipper as shown in Figure 15 show shows the now legal signal but the detail in the high
60. s found under Setup gt Lift Gain Menus 16 19 Proc amp main menu The proc amp enables the luma gain to be adjusted from 0 to 200 Similarly the chroma also is adjustable from 0 to 200 Full 10 bit by 10 bit multipliers are used with a rounded 10 bit product Black level adjustment is also applied at this point as is hue adjustment which allows for 180 of hue rotation I8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 3 2 6 Setting up the input video parameters Dual Link units only For the unit to function correctly it may be necessary to change some of the default input video parameters especially if the unit is to be used in dual link mode Changing the input video settings is done via the following menus found under Setup gt n Out gt i p Config Menus 108 111 Input details menu 1 2 Menus 112 115 Input details menu 2 2 Mode This can be set to either manual or SMPTE 352 SMPTE 352 mode allows the L 2s input video settings to be automatically detected via embedded SMPTE 352 information preset in the input video stream if such data exists If this is set to SMPTE 352 the following menus will not be changeable by the user Manual mode requires the following to be set up manually for correct operation of the Le a Link This is either single or du
61. s level of menus Go To Menus 44 47 Menus 52 55 YCC high clip and knee 36 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Menu Num Heading 52 YCC Y high clip 53 YCC Y high knee 54 55 Back Menus 56 59 YCC low clip and knee Function This menu adjusts the high YCC luma clip value Values are in percent This menu adjusts the high YCC luma knee value Values are in percent Pressing the button takes you to the previous level of menus Go To Menus 48 51 Menu Num Heading 56 YCC Y low clip 57 YCC Y low knee 58 59 Back Menus 60 63 YCC CC hi lo menu Function This menu adjusts the low YCC luma clip value Values are in percent This menu adjusts the low YCC luma knee value Values are in percent Pressing the button takes you to the previous level of menus Go To Menus 48 51 Menu Num Heading 60 YCC chroma high clip and knee setup 61 YCC chroma low clip and knee setup 62 Function Pressing the button takes you to the YCC chroma high clip and knee adjustment menu Go To Menus 64 67 Pressing the button takes you to the YCC chroma low clip and knee adjustment menu Go To Menus 68 71 37 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone
62. s menu is only operational with the KARMAudioRT option K Loudness Peak Back ve This menu sets the short term loudness limit above which the audio gain will begin to reduce The Loudness and Peak buttons provide access to more detailed loudness and peak processing parameters Menus 248 251 KARMAudioRT Loudness processing menu this menu is only operational with the KARMAudioRT option K 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com These menus allow configuration of the loudness processing parameters The Attack parameter effects how rapidly the audio gain is reduced when the loudness limit is exceeded The Decay parameter controls how quickly the audio gain recovers to unity after a loudness control event The Window parameter controls the length of the short term average used in the loudness calculation Menus 240 243 KARMAudioRT Peak processing menu this menu is only operational with the KARMAudioRT option K These menus configure the peak processing parameters Peak processing becomes active above the PKKnee level and all values between PKKnee and PKKnee PKClip PKKnee compression are soft limited Values above PKKnee PKClip PKKnee compression are hard clipped For the default values true peak levels below 11 dBTP are unaffected
63. ss Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Automation of the etherbox manual GeNETics protocol is used to control a number of processor cards using one connection PLEASE NOTE These commands are only active if the LOGGING mode is set to OFF see Section Error Reference source not found If a user preset is recalled that sets LOGGING back to ON these commands will become inactive again The command set is as follows Command Meaning Example hex string Mnn M emory nn is the 4D 30 31 memory preset Select Memory 01 which is the PAL number preset The number represents the following PAL preset M02 NTSC preset MO03 Bypass all Processing M04 0 100 RGB M05 EBU103 tight preset M06 EBU103 optimum preset M07 gt M12 User Presets 126 Initial preset number depends on line standard See User Memories 3 4 3 A response will occur within 100mS of the command The responses are as follows Response Meaning Hex string OK Command was understood and will implement 4F 4B EO Command timed out 45 30 ET Error 1 Unknown command 45 31 E2 Error 2 Memory number is not in range 45 32 5 3 geNETics Automation Protocol Parameter table This is the list of automatically extracted parameters for the LE 2 This is used for the generic geN Tics automation protocol See etherbox manual for
64. the Le 2 3 3 1 Ring suppression Ring suppression is controlled from the following menu found by navigating to Setup Comp Ring Supprn Menus 208 211 Ring suppression RGB percentage There are 3 different instances of this menu one for RGB in percent as shown above one for PAL in mV and one for NTSC in IRE The displayed menu will depend on the legalisation required and the domain selected Changes to the values within these menus are not copied across all three instances so settings for PAL NTSC and RGB are all stored separately Ring suppression can either be off on or auto In auto mode the high and low settings for the current legalisation type are used as the high and low clip values for the ring suppression el eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com 3 3 2 Adjusting the input picture blanking Adjustment of the input picture blanking parameters uses the menu below found under Utils 2 Blank The blanking is defined as the number of pixels in from the edge of the input video picture that you want to be blanked off e T isthe number of pixels of blanking from the top of the picture e Bisthe number of pixels from the bottom of the picture e Listhe number of pixels from the left edge of the picture e Ris the number of pixels from the right edg
65. this button loads the sixth Pressing this button loads the sixth button loads the sixth 49 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com user memory Back Pressing the button takes you to the previous level of menus Go To Menus 148 151 Pressing the next button on the panel will take you to the next menu in the nested menu sequence Go To Menus 168 171 Pressing the prev button on the panel will take you to the previous menu in the nested menu sequence Go To Menus 160 163 Menus 168 171 User memories menu 3 4 Menu Num Heading Function 168 Save user memory 1 Pressing this button saves the current unit settings to user memory 1 For details on the user memories see section 3 4 3 Save user memory 2 Pressing this button saves the Em unit settings to user memory a Save user memory 3 this button saves the current unit settings to user memory 3 Pressing the button takes you to the previous level of menus Go To Menus 148 151 171 Back Pressing the next button on the panel will take you to the next menu in the nested menu sequence Go To Menus 172 175 Pressing the prev button on the panel will take you to the previous menu in the nested menu sequence Go To Menus 164 167 5
66. true peak levels between 11dBTP and 8dBTP are soft limited and all true peak levels above 8dBTP are hard limited 3 3 4 PC Logging Application Installation The latest version of the logging application can be downloaded from http www eyeheight com FileDownload asp filename software compliance Com posite legaliser TimeCode utility zip The software requires the NET Framework v1 1 to be installed on the PC to be used for logging The NET Framework can be downloaded free of charge from http www microsoft com Extract all files in the Composite legaliser TimeCode utility zip file to a directory of your choice Run the TimeCode exe file to start the logger Setting Up for Logging For successful logging the unit needs to be set to generate the logging output by setting the Log Mode menu to on Menus 124 127 Data logger menu The unit then needs to be connected to a spare COM port on the PC make a note of the com port number as it will be required when configuring the logging 4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com software using a standard serial cable Finally the com port needs to be configured in the logging software via the Comms menu Understanding the Application The application provides a graphical log of the percentage of pixels in the inco
67. ts the black lift between 200mV and 200mV 27 Back Pressing the button takes you to the previous level of menus Go To Menus 16 19 Menus 28 31 RGB YCC main menu Menu Num Heading Function 28 RGB setup Pressing the button takes you to the RGB legalisation menu Go To Menus 32 35 29 YCC setup Pressing the button takes you to the YCC legalisation menu Go Menus 44 47 30 m 31 Back Pressing the button takes you to the previous level of menus Go To Menus 04 07 Menus 32 35 RGB hi lo menu Menu Num Heading Function 32 RGB high clip and Pressing the button takes you to the 34 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com mE knee setup RGB high clip and knee adjustment menu Go To Menus 36 39 33 RGB low clip and Pressing the button takes you to the knee setup RGB low clip and knee adjustment menu Go To Menus 40 43 34 35 Back Pressing the button takes you to the previous level of menus Go To Menus 28 31 Menus 36 39 RGB high clip and knee Menu Nam mm Heading Function RGB high clip This menu adjusts the high RGB clip value Values are in percent RGB high knee This menu adjusts the high RGB value Values are in percent 8 mA EE the button takes y
68. tton takes you to the 3I eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Proc amp settings menu Go To Menus 16 19 7 Back Pressing this button takes you to the previous level of menus Go To Menus 00 03 Pressing the next button on the panel will take you to the next menu in the nested menu sequence Go To Menus 08 11 Menus 08 11 Main menu set 2 2 Menu Num Heading Function 8 Input amp output video Pressing this button takes you to the settings input and output settings menu Go To Menus 104 107 9 Utilities menu Pressing this button takes you to the utilities menu Go To Menus 120 123 10 System menu Pressing this button takes you to the system menu Go To Menus 180 183 11 Back Pressing the button takes you to the previous level of menus Go To Menus 00 03 Pressing the prev button on the panel will take you to the previous menu in the nested menu sequence Go To Menus 04 07 Menus 12 15 KARMAudioRT menus this menu is only operational with the KARMAudioRT option K Menu Num Heading Function 12 KARMAudioRT Pressing this button status Enables Disables all KARMAudioRT 3e eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256
69. utomation protocol 61 5 2 1 Implimentation on RS232 a 61 5 3 geNETics Automation Protocol Parameter table 62 54 Technical Specification 72 dedasar cn ondas 72 SE 72 543 POIITIBIS ine dE 72 4 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Table of Figures Figure 1 LE 2U Processing card rr 7 Figure 2 L 2S and LE 2M Processing card 7 Figure 3 Front view of etherbox FB 9E fitted with FF 9 blank panel 7 Figure 4 Rear view of etherbox with a single L installed 8 A FP 9 Flexipanel can be fitted on the FB 9E or remotely using and i Figure 6 6 55 or LE 2M 9 Figure 7 LE 2U Connections tst 10 Figure 8 Flexipanel
70. y employing peak compression audio distortion is minimised KARMAudioRT is controlled from the following menus found by navigating to Setup next Utils KARMAudioRT eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eyesales eyeheight com Channel number Limits Back Lot The KARMAudio Enable button will toggle the KARMAudioRT audio processing on and off if the unit has the K option Operation of the KARMAudioRT is independant of the legaliser operation i e putting the legaliser into bypass will not bypass the KARMAudioRT processing The KARMAudioRT settings are stored and recalled by the user memories Menus 244 247 KARMAudioRT Channels this menu is only operational with the KARMAudioRT option K These menus select the embedded audio channel numbers 1 thru 16 that the KARMAudioRT loudness peak processing is performed on Press any red menu to access the individual parameters The first menu facilitates quick selection of industry standard channel allocations Adjusting any of the channel allocations will force the system to a custom channel allocation Only the channels identified will be processed by the KARMAudioRT processing Setting a channel to 0 will result it in being excluded from the KARMAudioRT calculations and processing Menus 176 179 KARMAudioRT Limits menu thi

Download Pdf Manuals

image

Related Search

Related Contents

FMT300BT Bedienungsanleitung  HC100 Benutzerhandbuch  RL78 Family CubeSuite+ Startup Guide    バッテリー付電源モデル  

Copyright © All rights reserved.
Failed to retrieve file