Install and Connect MCC1 (Multicarrier Cabinets

image

Contents

1. 047 NM MUMS Gee Coe Figure Notes 1 Cabinet 1 PPN with 1 Switch Node 2 Cabinet 2 through 15 EPN 3 H600 278 Metallic Cable 4 To other EPNs Return to Task List Connect Critical Reliability CSS Connected System with 1 Switch Node Begin Return to Task List Critical Reliability CSS Connected with 1 Switch Node shows typical fiber optic cabling between cabinets The cable between port slots 1 and 2 on each switch node is a metallic cable H600 278 Connect the 2 groups of 1 to 15 cables between the PPN and each EPN in an alternating port slot order 20 3 19 4 18 5 and so forth Critical Reliability CSS Connected with 1 Switch Node 9 TU NS MM WKS 7 74 Wl ars TMT ON TMU OX 0 cadfcr1 063097 Figure Notes 1 Cabinet 1 PPN with 1 Duplex Switch Node 2 Cabinet 2 through 16 EPN 3 H600 278 Metallic Cable 4 To other EPNs Return to Task List Install Telecommunications Cabling This section provides both informat
2. 1758155 CJL 031496 Figure Notes 1 Top of System Cabinets 2 Cable Clamps 3 Cable Ties Optional 4 Power Cord 5 Cable Slack Manager 6 Cable Slack Manager Cover Removed 7 Main Distribution Frame MDF 8 Route Cables Along Path Shown 9 Port Cables Return to Task List Install Sneak Fuse Panels Begin Return to Task List For general information see Sneak Fuse Panels The Model 507B Sneak Fuse Panel or equivalent is recommended for sneak current protection The panel contains two 25 pair connectors fuse removal tool and fifty 85 220029 sneak fuses and two spares See Sneak Fuse Connector Pinout for pinout data 1 Locate the 507B near the network interface or the Main Distribution Frame MDF 2 Hold the panel against the mounting surface and mark the mounting screw locations Drill pilot holes at the marked locations and partially install a locally obtained 12 x 3 4 inch screw into the two bottom mounting slots 3 Slide the sneak fuse panel onto the mounting screws and tighten the screws securely 4 Install a locally obtained 12 x 3 4 inch screw into the top two mounting slots and tighten securely 5 Repeat the procedure for each sneak fuse panel 6 Secure the B25A cable to the panel with the captive screw on the connector and a supplied cable tie Model 507B Sneak Fuse
3. 3150csu RBP 062696 Figure Notes 1 H700 348 quad cable 2 15 pin male D connectors to DTE jacks on CSU 3 Channel service unit CSU 4 H700 307 cable RJ 48C to RJ 48C 5 Network interface 6 Smart jack if provided 7 Cable A 8 Cable B 9 Cable C 10 Cable D DS1 Converter Connections Using Double Headed cable 283 cydf010 091399 Figure Notes 1 Port carrier 2 Backplane connector for TN570C EI 3 Backplane connector for DS1 Converter 4 50 pair female connector to El connector 5 14 in 35 6 cm Y cable 6 50 pin male 50 pin female double headed connector 7 H600 348 Quad Cable with 50 pin male connector which connects the Y cable to the 4 CSUs Y Cable Lengths Length Description 14 in 35 6 cm TN1654 circuit pack to adjacent El circuit pack or TN573B SNI circuit pack in same carrier 70 in 178 cm TN1654 circuit pack to El circuit pack or SNI circuit pack in another carrier 14 in 35 6 cm TN1654 circuit pack to fiber optic transceiver DC powered cabinets only This cable is for intercabinet cabling only 284 Install and Administer Trunks These links provide installation and wiring examples for analog and digital trunks These are examples only and actual wiring procedures may vary at each si
4. cydfdr08 LJK 101701 Figure Notes 1 Avaya Media Gateway 98 2 Digital line circuit pack 3 B25A 25 pair cable 4 Main distribution frame MDF 5 103A or Avaya modular wall jack 6 400B2 adapter 7 D6AP power cord 8400B only 8 Data module power supply 9 7 ft 2 m D8W modular cord 10 Data module 8400B top or 7400B bottom 11 50 ft 15 m M25A cable RS 232 12 Computer with Avaya Site Administration Return to Task List Connect Remotely to the Avaya Media Gateway Through a Modem Begin Return to Task List You can connect a PC to the Avaya Media Gateway through an analog modem to an INADS port Connect the equipment as shown in A typical remote connection through a modem to access a remote Avaya Media Gateway Follow these steps to connect to the Avaya Media Gateway through a modem 1 Connect the computer to the modem 2 Connect an analog telephone line to the leftmost analog line port on the modem 3 Make sure that the modem s DIP switches are set as shown in U S Robotics Modem DIP Switch Settings 4 Plug the modem into an AC power outlet 5 Turn on the modem 6 Set the following port settings Baud rate 9600 Data bits 8 Parity None Stop bits 1 Flow control hardware A typical remote connection through a modem to access a remote Avaya Media Gateway 99 Eae c9
5. eee eee 1758582b MMR 042996 Figure Notes 1 To Network Interface Facility 2 To Blue or White Station Distribution Field 3 To TN2183 or Equivalent Analog Line Circuit Pack 4 To TN747 or Equivalent Central Office Trunk Circuit Pack 5 To Power Transfer Unit 6 To Control Carrier AUX Connector Return to Task List Install Telephones Used Only for Emergency Transfer Trunk Auxiliary Field Begin Return to Task List 1 Connect a pair of wires between the 48V and GRD terminals on the yellow emergency transfer row connecting block and the EM TRANS RELAY PWR terminal See Connections for Telephone Used for Emergency Transfer 2 Connect Central Office CO trunk leads from the purple field to TC terminals on the yellow emergency transfer row connecting block for each trunk 3 Connect CO trunk leads from the green field to TK terminals on the yellow emergency transfer row connecting block for each trunk 175 4 Connect ST leads on the yellow emergency transfer row connecting block for each emergency transfer telephone to the assigned terminal in the blue or white station distribution field The ST terminal leads should be terminated on the following pairs 1 4 7 10 13 16 19 or 22 the first pair of any 3 pair group 5 Install the telephone Connect telephone to the information outlet Install patch cords jumper wi
6. fpdfmapd KLC 030899 261 Figure Notes 1 LCD display 2 Reset button recessed 3 Red board status LED 4 PCMCIA card slot 5 Yellow PCMCIA disk in use LED J58890MA 1 L30 IP Interface Assembly indfmapd KLC 031299 Return to Task List Test the Modem Begin Return to Task List 1 Check for dial tone 2 Contact Avaya Support and ask a representative to dial in to your IP Interface server Administer the IP Interface Begin Return to Task List Administration is done either locally or remotely If administered locally proceed with the following administration steps If administered remotely call your service representative to start the process 1 Log in as craft 262 Note If you have a dadmin login and password you can use them instead of craft and the craft password 2 Type change circuit pack and press Enter 3 In Circuit Packs Screen 1 check the Code column to see if the slots above the TN802B says DSMAPD or MedPro 4 If MEDPRO go to the entry just above the TN802B that says MEDPRO 5 Type DSMAPD and press Enter Changing the one entry automatically changes the entry above it If it is in IP Trunk mode you get the following error message MedPro type requires TN802 with application Type MEDPRO on circuit packs form Circuit Packs Screen 1 change circuit packs Page 1 of 5 Cabinet Slot Code 01 TN754 02 TN758 03 TN2144
7. Installation for MCC1 Multicarrier Cabinets Made Easy Release 1 3 May 2003 Copyright 2003 Avaya Inc All Rights Reserved Notice Every effort was made to ensure that the information in this document was complete and accurate at the time of printing However information is subject to change Warranty Avaya Inc provides a limited warranty on this product Refer to your sales agreement to establish the terms of the limited warranty In addition Avaya s standard warranty language as well as information regarding support for this product while under warranty is available through the following website http www avaya com support Preventing Toll Fraud Toll fraud is the unauthorized use of your telecommunications system by an unauthorized party for example a person who is not a corporate employee agent subcontractor or is not working on your company s behalf Be aware that there may be a risk of toll fraud associated with your system and that if toll fraud occurs it can result in substantial additional charges for your telecommunications services Avaya Fraud Intervention If you suspect that you are being victimized by toll fraud and you need technical assistance or support in the United States and Canada call the Technical Service Center s Toll Fraud Intervention Hotline at 1 800 643 2353 How to Get Help For additional support telephone numbers go to the Avaya Web site http www ava
8. J Battery Reserve 1145 Power U nit Charging Battery Output Power On 00000000000000 0 0 TULLU 5 9900000090090009000 0004 1 PDH 062596 Figure Notes 1 Wall Mounting Plate 2 Second 1146B Power Distribution Unit 3 Cable H600 347 G7 4 First 1146B Power Distribution Unit 5 1145B Power Unit Return to Task List 190 Install the Battery Mounting Wiring Begin Return to Task List Three types of back up batteries are used See Back Up Battery Rating for the battery type and rating 1 Insert two 10 32 x 1 2 inch shoulder screws into the top designated battery holes on the wall mounting plate Lightly screw in but do not tighten 2 Place the keyhole slots in the battery bracket on these two screws The battery cord exits from the right of the bracket Make sure the label on the battery is visible Tighten the screws securely 3 Plug the battery cord into the power supply s right rear receptacle The rear receptacle is indicated on the right label Back Up Battery Rating Battery Rating 1148B 2 5 amp hours 1149B 5 amp hours 1147B 8 amp hours Return to Task List Install the Expanded Power Distribution Unit Begin Return to Task List A second power distribution unit can be installed to pr
9. Network Intrface 9 9 Yellow Field 25 Pair pea TL 1 HE 1219 war dd 25 Pair Cable 25 Pair Cable o 1 7 09 0 M SONS Trunk Circuit Pack Line Circuit Pack Figure Notes 1 Rear of Port Cabinet 2 Main Distribution Frame MDF 3 Port Distribution Field Purple Field 4 Station Distribution Field White Field 5 Trunk Auxiliary Field 6 Purple Field 7 Yellow Field 8 Green Field 9 Satellite Closet 10 Auxiliary Cabinet Yellow Field 11 White Field 12 Blue Field 13 Cross Connect Jumpers 14 103A or Modular Wall Jack 15 4 Pair Line Cord 16 To Line Circuit Pack 51 Cable A A i 2 e 12 e L 2 2 2 2 25 Pair Cable 0016 0 052396 4 Port Tie Trunk 4 Port Tie Trunk w E amp M Signaling Example MDF Connections MCC1 Multicarrier Cabinet 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 2
10. Bracket Attachments LUMI OE OD MMU LI NY V lcda7fop 051198 2 398 Figure Notes 1 Fiber cable 2 connector adapter bracket 3 SC SC adapter 4 SC ST adapter Cable disconnect label prda0001 RPY 021898 Replace the fan cover 399 d 2 5 G Na 2 SA D A Ci ZA amp A Sy 22 x CR RSI f AA RS 2 21 a 224 AT 4 AT 1 A d A Sy l lt EN H N A q D 2 D 1 q IN 2 p 1 2 2 x lt lt 6 Connect fiber cable to circuit pack scdafo_4 051298 Dress the cable 401 Icda4fop RPY 021398 Test the Installation Begin Return to Task List 1 Log into the management terminal 2 Administer the system by referring to Administering Fiber Optic Cables 3 Type list configuration all and press Enter to determine if the new circuit pack appears in the correct slot and that there are no circuit pack conflicts Return to Task List 402 Administering Fiber Optic Cables Note You administer Fiber Optic Cables only on a
11. Ne Return to Task List Install ISDN PRI Trunks Return to Task List If packet bus support for Avaya Media Gateway si must be added and TN750s must be installed as part of that support then adding ISDN PRI requires a service interruption Notify the customer in advance as to when the addition will be carried out See Add Packet Bus Support for further information Task List Installing ISDN PRI Trunks 1 Installing ISDN PRI in North American Installing ISDN PRI Internationally Add Packet Bus Support ISDN PRI Add Circuit Packs ISDN PRI Install Cables ISDN PRI Enter Added Translations ISDN PRI Resolve Alarms ISDN PRI 8 Save Translations ISDN PRI Return to Task List 0 NM Installing ISDN PRI in North American Begin Return to Task List 294 1 Use a TN767E or later DS1 or a TN464F DS1 E1 circuit pack for a signaling link and up to 23 ISDN PRI Trunk Group members 2 Install a Tone Clock circuit pack to provide synchronization for the DS1 circuit pack 3 If using a TN464F then packet bus support has not been added requiring greater than 4 PRI signaling groups see Add Packet Bus Support for installation of additional circuit packs for packet bus support As an option to the TN768 or TN2182B Tone Clock a TN780 Tone Clock installed in the PPN can interface external Stratum 3 synchronization for DS1 Return to Task List Installing ISDN PRI Internationally
12. m fiber link next Page 3 of 3 UN FIBER LINK ADMINISTRATION B PNC 051 CONVERTER DS1CONV ATTRIBUTES DS1CONV Board Location 01C01 DS1CONV Board Location 02C01 DS1CONV Board Type TN574 DS1CONV Board Type TN574 DS1 CONVERTER FACILITIES A B Facility Installed yes no no no Passes Far end Clock yes yes yes yes Digital Data Compatible yes yes yes yes Line Coding ami zcs ami zcs ami zcs ami zcs Framing Mode esf esf esf esf DS1CONV 1 Line Compensation 1 1 1 1 DS1CONV 2 Line Compensation 1 1 1 1 Facility B Circuit ID 01112343 ER Zz Return to Task List 410 DS1 Converter Complex Administration for T1 TN1654 Circuit Packs Return to Task List Fiber Link Administration form for T1 TN1654 Circuit Pack DS1 Converter Complex Administration page 2 of 3 shows the fields available to administer the TN1654 circuit pack The following unique fields display when administering a T1 TN1654 DS1 Converter e Bit Rate Displays when the 051 Converter circuit pack is TN1654 Enter either 1 544 for domestic T1 operation or 2 048 for international E1 operation Note Since one bit rate applies for all facilities within the same DS1 Converter complex the Bit Rate field displays only under Facility A e Facility Startup Idle Code Displays when the DS1 Converter circuit pack is TN1654 Enter 8 digits each digit must be 0 or 1 The second digit must be 1 Default is 11101000 You can administer
13. addfipm2 083000 Figure Notes 1 Amphenol connector to backplane connector corresponding to TN2302AP slot 2 To Ethernet 3 9 pin connector for maintenance Return to Task List Installing the TN2302AP IP Media Processor To install a TN2302AP IP Media Processor you must install One or more TN2302AP circuit pack One or more TN799x circuit pack each TN799x can support more than one TN2302AP An IP Media Processor adapter Task List Install TN2302AP Perform these tasks in order 1 Connect the cables for TN799x 2 Connect the cables for TN2302AP 3 Connect the Ethernet 4 Install the Circuit Packs 5 Perform Initial Administration Steps for C LAN and IP Media Processor 6 Test the External Connection to the LAN Connect the cables for TN799x Begin Return to Task List 1 Determine into which port slots you are putting the TN799x C LAN circuit packs From the rear of the cabinet 2 Connect the 259A connector to the backplane connector corresponding to the TN799x slot 236 3 Connect one end of the CAT5 cable to the 259A connector Connect the other end to the customer s network Connect the cables for TN2302AP Begin Return to Task List 1 Determine into which port slots you are putting the TN2302AP IP Media Processor circuit packs From the rear of the cabinet 2 Connect the amphenol connector on the adapter to the backplane connector corresponding to each TN2302AP slot Connect t
14. crd 24o0 CJL 101396 Figure Notes 1 Locally Engineered Cables and Equipment 2 25 Pair Connector 3 Multi Pair Protector Units Primary Protectors with Heat Coils or Equivalent with Sneak Current Protection 4 B25A Cable Male to Female 5 Concentrator Cable WP90929 List 1 6 356A Adapter 7 Out of Building Wiring 8 Out Of Building Analog Telephones 9 Part of Main Distribution Frame MDF 10 Station Side 11 System Side 12 White Field 13 Purple Field 14 Cross Connect Jumpers 15 Tip and Ring Wires Return to Task List Off Premises Protection Requirements Return to Task List Both building entrances require carbon block or equivalent protection and sneak current protection Protection can be provided by 164 a4 type protector which is equipped with a heat coil e a3 type protector plus a separate sneak current protector The 4 type protector is the preferred device For installations not using primary protection 4 type protectors should always be used When the 3 type protector is already installed a separate sneak current protector is required The multi pair protector units and the off premises cabling must be locally engineered Connectorized multi pair protector units female 25 pair connector are recommended Analog Line Circuit Protectors shows the recommended protectors The protectors can be ordered from the Premises Distribution Systems Equipment and Supplies Catalog
15. 87 2 28 3 29 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 W BL BL W W O O W W G G W W BR BR W W S S W R BL BL R R O O R R G G R R BR BR R R S S R BK BL BL BK BK O O BK BK G G BK BK BR BR BK BK S S BK Y BL TTC1 RTC1 TTK1 RTK1 TLC1 RLC1 TST1 RST1 TTC2 RTC2 TTK2 RTK2 TLC2 RLC2 TST2 RST2 TTC3 RTC3 TTK3 RTK3 TLC3 RLC3 TST3 RST3 TTC4 RTC4 TTK4 RTK4 TLC4 RLC4 TST4 173 Tip PBX Trunk Circuit 1 Ring PBX Trunk Circuit 1 Tip CO Trunk Circuit 1 Ring CO Trunk Circuit 1 Tip PBX Line Port 1 Ring PBX Line Port 1 Tip Emergency Terminal 1 Ring Emergency Terminal 1 Tip PBX Trunk Circuit 2 Ring PBX Trunk Circuit 2 Tip CO Trunk Circuit 2 Ring CO Trunk Circuit 2 Tip PBX Line Port 2 Ring PBX Line Port 2 Tip Emergency Terminal 2 Ring Emergency Terminal 2 Tip PBX Trunk Circuit 3 Ring PBX Trunk Circuit 3 Tip CO Trunk Circuit 3 Ring CO Line Port 3 Tip PBX Line Port 3 Ring PBX Line Port 3 Tip Emergency Terminal 3 Ring Emergency Terminal 3 Tip PBX Trunk Circuit 4 Ring PBX Trunk Circuit 4 Tip CO Trunk Circuit 4 Ring CO Trunk Circuit 4 Tip PBX Line Port 4 Ring PBX Line Port 4 Tip Emergency Terminal 4 Pin Assignments for 25 Pair Connector 16 BL Y RST4 Ring Emergency Terminal 4 42 Y O TTC5 Tip PBX Trunk Circuit 5 17 O Y RTC5 Ring PBX Trunk Circuit 5 43 Y G TTK5 Tip CO Trunk Circuit 5 18 G Y RTK5 Ring CO Trunk Circuit 5 44 Y B
16. About DCS Switch Settings About 7400D Data Module Option Settings External Modem Option Settings Printer Option Settings Call Detail Recording Option Settings AUDIX Interface Option Settings TN760D Tie Trunk Circuit Pack Option Settings TN464 2464 Option Settings Refer to the user s guide for each type of equipment for information on how to locate and set the option switches Data Module Option Switch Settings Return to Task List This section contains information About DCS Switch Settings About 7400D Data Module Option Settings Task List Data Module Switches and Options Set DCS Switches Set 7400D Options Set 7400A and 7400B Options About DCS Switch Settings The Distributed Communications System DCS for a system is connected to the system through the Processor Interface circuit pack The first circuit can be connected directly to the DCS through the processor interface connector on the rear of the control carrier Any of the remaining three circuits on the processor interface used to support the Distributed Communications System DCS must be connected through a data module serving as the interface link The option settings for a 7400A Data Module are shown in Data Module Option Switch Settings Refer to Data Module DIP Switch Locations for the location of the switches 365 Data Module Option Switch Settings DIP Switch Function Setting 1 With Phone ON Without Phone OFF 5 Data Metering ON No Dat
17. Begin Return to Task List 1 Install a TN464C or later DS1 E1 circuit pack for the assignment of the 2 signaling channels and up to 30 ISDN PRI Trunk Group members Each E1 span provides 32 ports 2 Install a Tone Clock circuit pack to provide synchronization for the DS1 E1 circuit pack 3 If packet bus support has not been added and greater than 8 PRI signaling groups are required see Add Packet Bus Support for installation of additional circuit packs for packet bus support As an option to the TN2182B Tone Clock a TN780 Tone Clock installed in the PPN can interface external Stratum 3 synchronization for DS1 Return to Task List Add Packet Bus Support ISDN PRI Begin Return to Task List If packet bus support is not already installed see Add Packet Bus Support and perform the steps Add Circuit Packs ISDN PRI Begin Return to Task List 1 Determine port assignment of circuit packs to be added 2 Install the DS1 Interface circuit pack in the assigned carrier slot 3 Install a TN748B or later or the international TN420B C Tone Detector circuit pack if required Install Cables ISDN PRI Begin Return to Task List Install cables from cabinet to MDF as required Enter Added Translations ISDN PRI Begin Return to Task List Administer the forms listed under Integrated Services Digital Network Primary Rate Interface in the Administrator s Guide for Avaya Communication Manager
18. Begin Return to Task List Cross connect the network jack on the modem to the network interface via a 103A or modular wall jack See Pinout of Network Jack and Network Jack on U S Robotics Modem Pinout of Network Jack Pin Number 1 2 3 4 Network Jack on U S Robotics Modem 325 Signal Unused Tip Ring Unused Sportster 33 6 Faxmodem OO TS AROFAX AK 1 OW 9 O modmcabl KLC 110397 Figure Notes 1 Pin 1 of network jack 2 Modem Return to Task List Set External Modem Options Begin Return to Task List A locally obtained type approved external modem may be used Contact your Avaya representative for information 1 Set the modem switches Ifa U S Robotics Model 839 modem is installed refer to U S Robotics Model 839 External Modem Switch Settings to set the 8 option switches on the U S Robotics modem f any other modem is installed refer to the setup instructions provided with that modem Refer to SCC1 Modem Fields while setting up the modem 2 Atthe management terminal enter change system parameters maintenance and press Enter 3 Scroll to page 3 of the form Set the Modem Connection field to external if a modem is installed Set the field to none if no modem is installed Note This field must be administered or alarms will be generated The Modem Connection field cannot be set to none if Alarm Or
19. Verify the screen displays command successfully completed Typical Change Password Screen change password craft Page 1 of 1 SPE A PASSWORD ADMINISTRATION Password of Login Making Change LOGIN BEING CHANGED Login Name craft LOGIN S PASSWORD INFORMATION Login s Password Reenter Login s Password Return to Task List Set Daylight Savings Rules Begin Return to Task List You can set up to 15 customized daylight savings rules See Typical Daylight Savings Time Rules If you have switches in several different time zones you can set up rules for each A daylight savings time rule specifies the exact time when you want to transition to and from daylight savings time It also specifies the increment at which to transition 1 Type change daylight savings rules and press Enter 2 Type the appropriate start and stop information in the Change Day Month Date Time and Increment for example 1 00 equals one hour fields for each rule 115 Note You can change any rule except rule 0 zero You cannot delete a daylight savings rule if it is in use on either the Locations or Date and Time screens 3 Press Enter Typical Daylight Savings Time Rules SAVINGS RULES Rule Change Day Month Date Time Increment 0 No Daylight Savings 1 Start first Sunday on or after April 1 at 3 00 01 00 Stop first Sunday or after October 25 at 3 00 2 Start first Sunday on or after April 1 at 4 00 01 00 Stop
20. test firmware download SPE A TEST RESULTS Port Maintenance Name Alt Name Test No Result Error Code FW DWNLD 1413 PASS Backing out of a firmware download 2 Look in the Result field for FAIL PASS conditions The Result field in the screen shows PASS indicating a successful test of the firmware download circuitry If the Result field shows FAIL refer to the maintenance book need full title here or link in the FW DWNLD maintenance object section subsection entitled System Technician Demanded Tests Descriptions and Error Codes Resolve every error and rerun the test When the test passes every specified resource is currently available for the scheduled download Note however that this does not guarantee the resource will still be available at the time of the download To back out of a completed firmware download and revert to the previous image follow the same download procedure you did before except use the previous firmware vintage instead The exception is TN799DP C LAN and TN2501AP VAL which have a separate procedure Reverting to an older TN799DP or TN2501AP vintage To revert back to the old firmware image file on a TN799DP C LAN or TN2501AP VAL only 1 Type get boot image UUCSS and press Enter to check the status of the firmware images on the target circuit pack set boot image 1C07 DISPLAY FIRMWARE IMAGE S Image 1 Image 2 Board Type TN2501 TN2501 FW Vintage 02 01 HW Signature 02
21. 9 Voice Terminal Label Control Carrier Cable Begin Return to Task List 1 Place the appropriate AUX connector label on the assigned 110 type terminal block row 2 On the control carrier cable place a yellow auxiliary label on the connectors at each end of the cable 3 Write AUX on each label Connect Control Carrier Outputs Cable Begin Return to Task List 1 Plug the connector cable in the AUX connector on the rear of the Control Carrier 2 Route the connector cable through the cable slack manager to the assigned 110 type terminal block in the yellow field of the trunk auxiliary field Connect Trunk Pairs Using Concentrator Cables Begin Return to Task List Connect Trunk Pairs Using Concentrator Cables shows trunk pairs connected to the cabinet with concentrator cables To install the cables 1 Connect B25A cables between the network interface and sneak fuse panels 2 Connect A25D cables from the sneak fuse panels to the 110 type terminal block connectors in the green field 3 Connect patch cords jumper wires from the terminal block in the green field to the associated terminal block in the purple field 4 Connect the single fingered end of the concentrator cables to the 110 type terminal block connectors in the purple field in Step 3 5 Connect the other end 2 3 fingered end of the concentrator cables to the appropriate carrier slots Equipped carrier slots are identified on the CSD Mark the n
22. Analog Line Circuit Protectors Primary Primary Sneak Current with heat coil Protectors1 3B1A carbon 4B1C carbon 220029 Fuse 3B1E W 4B1E W SCP 1 wide gap gas tube wide gap gas tube 3C1S 4C1S solid state solid state 1 The 3 type protectors should be used only if they are already part of the existing protection system A sneak current protector is always re quired when a 3 type primary protector is used Return to Task List Voice Terminal Restrictions for Exposed Environments Begin Return to Task List The following voice terminals cannot be installed in an exposed environment 7300 type voice terminals connected to TN762 Hybrid Line circuit packs e Multi button Electronic Telephone MET sets connected to TN735 Multi button Electronic Telephone MET Line circuit packs Analog telephones connected to TN746 Analog Line circuit packs Return to Task List Digital Out of Building Voice Terminal Protection Begin Return to Task List For information about specific protectors see Installing the ITW Linx Enhanced Protector Installing the 4C3S 75 Enhanced Protector Installing the Data Link Protector 165 Digital out of building voice terminals require protection at both building entrances The 4C3S 75 Enhanced Protector and the ITW Linx Enhanced Protector can be used to protect digital voice terminals and digital line circuit packs These units provide primary and sneak current protection The
23. Begin Return to Task List 1 Administer the TN799DP C LAN Refer to the Administration for Network Connectivity for Avaya Communication Manager 2 Administer the IP Media Processor which is usually done remotely Call your service representative to start the process 3 Complete the administration and testing See Perform Initial Administration Steps for C LAN and IP Media Processor and Test the External Connection to the LAN for detailed instructions Return to Task List Upgrading a TN802B IP Interface Assembly to TN2302AP IP Media Processor Return to Task List To upgrade IP Interface Assembly to IP Media Processor you must replace the TN802B circuit pack with a TN2302AP circuit pack the TN799 circuit pack with a TN799DP circuit pack if necessary the H600 512 G1 external cable assembly with an IP Media Processor adapter Task List Upgrade TN802B to TN2302AP 1 Perform Pre upgrade Administration 2 Remove the Circuit Packs 3 Replace the Cables 4 Install the Circuit Packs 5 Perform Additional Administration Steps Perform Pre upgrade Administration Begin Return to Task List 1 Type change ip interfaces and press Enter See IP Interfaces screen 2 Setthe Enable Eth Pt field to n 3 Press Enter to effect the change 4 Type change ip interfaces and press Enter 5 Delete the information in the Type Slot and Node Name fields for each TN802B you are replacing 6 Press Enter to save the information and effec
24. 1 Choose an alarm to connect such as Battery Interface Failure 2 Choose the port circuit pack to use and its carrier and slot number from Port Circuit Pack and Telephone Pin Designations For example TN2183 Analog Line Cabinet 1 Carrier C Slot 1 3 Choose a port circuit on the port circuit pack for example Port 3 4 Install cross connect jumpers to connect the named pins from the alarm wires to the appropriate pins on the port circuit pack Note It is recommended that the RFA ACF and BIF alarm leads be connected to the major alarm device and the BOD alarm leads be connected to the minor alarm device 5 Connect the major and minor alarm devices to the appropriate cross connect pins on the MDF 6 Administer the alarms using the Administrator s Guide for Avaya Communication Manager External Alarm Connector Pinout Pin Designation Definition 26 Not Used 1 Not Used 27 Not Used 2 Not Used 28 Not Used 3 Not Used 29 Not Used 157 External Alarm Connector Pinout Pin 4 30 5 31 6 32 7 33 8 34 9 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 Designation Not Used Not Used Not Used Not Used Not Used Not Used Not Used RFA2 RFA2 ACF2 ACF2 BIF2 BIF2 BOD2 BOD2 Not Used RXD TXD DTR RS 232 GRD DSR RTS Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not Used Not U
25. 25 6 At the AC load center connect a 10 AWG 25 6 wire to the single point ground block This ground wire will later be tie wrapped to the trunk cables and connected to the Coupled Bonding Conductor CBC ground block at the MDF The Coupled Bonding Conductor CBC wires are installed and terminated in Install Telecommunications Cabling Typical Cabinet Ground Location 7 widmgrnd LJK 092697 Figure Notes 1 PPN Cabinet 2 EPN Cabinet if Installed 3 6 AWG 40 16 mm CABINET GROUND Wire 4 Cabinet Ground Terminal Block 5 AC Load Center Single Point Ground 6 Less than 50 Wire feet 15 2 m 7 10 AWG 25 6 mm Ground Wire to CBC Return to Task List Ground AC Load Center More Than 50 ft 15 2 m from Cabinet Begin Return to Task List 1 Mount the single point ground block to any surface between the MCC cabinets and the AC load center single point ground The single point ground block must be mounted to a non metallic surface 26 2 At the bottom rear of the PPN cabinet connect a 6 AWG 40 16 mm CABINET GROUND wire to the cabinet ground block See Typical Cabinet Grounding Wiring Diagram 3 Route the opposite end of the wire to the single point ground block and connect 4 At the first EPN cabinet if provided DC Power Cabinet connect a the 6 AWG 40 16 4 mm CABINET GROUND wire to the cabinet ground terminal block GROUND DIS
26. 3 T1 Channel Service Unit CSU 3150 Shown 4 T Tip 5 R Ring 6 T1 Tip 1 7 R1 Ring 1 147 8 1 544 Mbps Digital Service Interface 9 To T1 Carrier DS1 Cables Connector Cable C6C connector cable C6D connector cable C6E connector cable C6F connector cable Description and Usage 50 foot 15 2 m shielded cable equipped with a 50 pin male connector on one end and a 15 pin male connector on the other end Use this cable to connect a DS1 tie trunk circuit pack to a Channel Service Unit CSU 50 foot 15 2 m shielded cable equipped with a 50 pin male connector on each end Use this cable to connect a DS1 tie trunks in collocated cabinets 100 foot 30 5 m shielded cable equipped with a 50 pin male connector on one end and a 50 pin female connector on the other end Use this cable as an extension cable between the DS1 tie trunk circuit pack and other connector cables 50 foot 15 2 m shielded cable equipped with a 50 pin male connector on one end and a three inch 7 62 cm stub on the other end Use this cable to connect the DS1 tie trunk circuit pack to channel multiplexers requiring hardwired connections Pinout of C6F Cable Wire Color White Green Green White Brown Brown White Slate Slate Return to Task List Auxiliary Connector Outputs Return to Task List Connect a 25 pair cable from the AUX connector on the back of the control carrier Lead Pin Designation
27. 4 Repeat steps 1 through 4 for the backup card 5 Remove the backup translation card from the processor circuit pack and replace it with the original translation card 6 Label the backup card with the date and time of the backup Store the backup card in a secure place 7 Repeat this process for High or Critical Reliability systems Return to Task List Save Translations Avaya DEFINITY Server r Begin Return to Task List This command copies the current system translations onto the translation card or removable media For standard reliability systems one removable media for backup is required For high or critical reliability systems two removable media for backup are required To copy the current system translations onto both disks 1 Type save translation and press Enter 2 Verify the save completes to both disks and returns a result code of 0 zero Add Translations Avaya DEFINITY Server si Begin Return to Task List 1 To add new terminals refer to the Administrator s Guide for Avaya Communication Manager 2 Type save translations and press Enter to merge these translations with the contents of Flash memory Add Translations Avaya DEFINITY Server r Begin Return to Task List 1 To add new terminals refer to the Administrator s Guide for Avaya Communication Manager 2 Type save translation and press Enter to merge these translations with the contents of the disk 120 If a standa
28. 9 e cydr0031 KLC 091200 Figure Notes 1 Computer with Avaya Site Administration 2 50 ft 15 m M25A cable RS 232 9 25 pin adapter if needed 3 Analog modem 4 7 ft 2 m D2W modular cord 5 103A or Avaya modular wall jack 6 Main distribution frame MDF 7 Analog line circuit pack 8 Analog trunk circuit pack Packet data line r Data line r 9 Avaya Media Gateway 10 B25A cable 11 Analog line U S Robotics Modem DIP Switch Settings Dip Setting Description Switch 1 UP Data Terminal Ready normal DOWN Data Terminal Ready override 2 UP Verbal result codes DOWN Numeric result codes 3 UP Suppress result codes DOWN Display result codes 4 UP Echo offline commands DOWN No echo offline commands 5 UP Auto answer on first ring or higher if specified in DOWN NVRAM Auto answer off 100 U S Robotics Modem DIP Switch Settings Dip Seiting Description Switch 6 UP Carrier detect normal DOWN Carrier detect override 7 UP Load NVRAM defaults DOWN Load factory defaults 8 UP Dumb mode DOWN Smart mode Return to Task List Set the Data Module to DCE Mode Begin Return to Task List 1 Cycle the power to the data module The unit performs a self test and displays its operating mode Observe the display If the display reads DCE mode proceed to Add a Data Module to the Switch 2 Ifthe display reads DTE mode reverse the mode select circuit board Remove the power cord from the uni
29. Begin Return to Task List Note These instructions are for connecting the U S Robotics modem supplied to U S customers only If using a different modem follow the manufacturer s instructions on connecting the modem 1 Connect the RS232 port of the modem to the MODEM connector of the TN802B external cable assembly Note Check the labels near the connectors the MODEM and COM connectors look the same 2 Connect an analog telephone line to the left most analog line port on the modem as shown in External Modem Connections for U S Robotics Modem 3 Make sure that the modem s DIP switches are set as shown in External Modem Connections for U S Robotics Modem and U S Robotics Modem Dip Switch Settings 4 Plug the modem into an AC power outlet 5 Turn on the modem using the switch on the front of the modem External Modem Connections for U S Robotics Modem modfrobo KLC 030499 249 Figure Notes 1 Connect analog line here 2 DIP switch 5 must be up 3 Connect MODEM connector here 4 Connect power connector here U S Robotics Modem Dip Switch Settings Dip Switch 1 Setting UP DOWN UP DOWN UP DOWN UP DOWN UP DOWN UP DOWN UP DOWN UP DOWN Description Data Terminal Ready normal Data Terminal Ready override Verbal result codes Numeric result codes Suppress result codes Display result codes
30. Circuit Carrier Quantity Slot Pack TN570 Control Carrier A 1 or 2 EXPN INTFC 1 and 2 Control Carrier B if 10r2 EXPN INTFC 1 and 2 duplicated TN771C Control Carrier A 1 Any available port slot 1 Quantity of this pack should equal the number of EPNs 2 Required for critical reliability EPNs and PPN Optional for digital trunk testing in high reliability PPN Power Up System Packet Bus Support Begin Return to Task List 1 At the EPN set the main circuit breaker to ON 2 Atthe PPN set the main circuit breaker to ON 3 The system performs a level 4 reboot loading the system translations from the translation cards Rebooting takes about 10 minutes 4 After all trouble is cleared verify the EMERGENCY TRANSFER CONTROL switch is set to AUTO This restores the system to the normal mode Return to Task List 221 New Duplicated G3r installations only New simplex and upgraded G3r only Deliver or install the License File Packet Bus Support Begin Return to Task List A CAUTION This procedure must be done immediately after you upgrade the software If the license file is not installed within 10 days the switch enters a No License mode and shuts down all call processing 1 Retrieve the RFA License File with both serial numbers from the RFA Application Type set time and press Enter Ensure that the system date and time are set correctly Use one of these installation methods Direct connection b
31. The TN802B IP Interface operates in two modes IP Trunk available with Release 7 or later Media Processor MedPro available with Release 10 or later The IP Trunk mode is Internet Telephone Server Enterprise ITS E compatible and the MedPro mode is H 323 V2 compatible The TN802B IP Interface is backwards compatible and defaults to IP Trunk mode You must administer it to use it in MedPro mode TN2302AP Media Processor Unlike the TN802B IP Interface Assembly the TN2302AP operates in one mode Media Processor MedPro which is H 323 V2 compatible For more information on the IP Solutions capabilities and limitations refer to the Overview for Avaya Communication Manager Installing a TN2302AP IP Media Processor Return to Task List Installing a TN2302AP media processor consists of 4 sets of tasks Preparing for Installation and Upgrade Installing the TN2302AP IP Media Processor Upgrading TN802 IP Trunking to TN2302AP IP Media Processor Upgrading a TN802B IP Interface Assembly to TN2302AP IP Media Processor For administration refer to the Administration for Network Connectivity for Avaya Communication Manager Preparing for Installation and Upgrade This section includes general information on preparations and the Task List Prepare for Installation and Upgrade In addition to the TN2302AP IP Media Processor you must also install and administer a C LAN circuit pack 7N799x For C LAN administration refer to Adm
32. 1 The image is copied from an Avaya server over the Web to a local staging area or server on the customer LAN 2 The image is copied from the local staging area to the source circuit pack 3 The image is downloaded from the source to the target with one of these methods Fora self download the image is downloaded directly from RAM the source to flash memory the target on the same circuit pack Fora C LAN distributed download the image is downloaded from RAM the source on a C LAN circuit pack to flash memory the target on one or more separate circuit packs of the same type Although different circuit packs have different potential roles in a firmware download currently the following circuit packs can participate in a firmware download procedure Additional circuit packs will be added in the future TN799C or TN799DP Control LAN C LAN TN2214CP orTN2224CP 2 Wire Digital Line DIG LINE TN2302AP IP Media Processor IPMEDPRO TN771DP Maintenance Test M T ANL TN464GP TN2464BP and TN2313AP UDS1 TN2501AP Voice Announcements over LAN VAL See Programmable Circuit Pack Roles in Firmware Downloads on page 342 for each circuit pack s roles in a firmware download 341 Self C LAN distributed download procedure Programmable Circuit Pack Roles in Firmware Downloads Role in C LAN distributed Circuit Pack TN Code Role in Self Download Download C LAN TN799C Source TN799DP
33. 5 To complete the administration refer to the Administration for Network Connectivity for Avaya Communication Manager book Circuit Packs Screen 1 207 change circuit packs Cabinet 1 Slot Code Sf Mode Name 01 TN754 DIGITAL LINE 02 TN758 POOLED MODEM 03 TN2144 ANALOG LINE 04 TN746 B ANALOG LINE 05 06 TN771 C MAINTENANCE TEST 07 TN464 F DS1 INTERFACE 08 TN2140 E amp M TIE TRUNK 09 TN767 E DS1 INTERFACE 10 TN799 B CONTROL LAN indicates circuit pack conflict CIRCUIT PACKS Return to Task List Page 1 Carrier A Carrier Type processor Slot Code Sf Mode Name 278 11 12 13 14 15 16 MEDPRO RESERVED IP MEDPRO RESERVED IP TN802 B MAPD BOARD of Add Channel Service Units A channel service unit CSU can be either an integrated CSU ICSU module or a 3150 3170 CSU module See the relevant topics About Installing an ICSU Module Installing the 120A3A CSU Installing a 3150 3170 Channel Service Unit About Installing an ICSU Module The integrated channel service unit ICSU is a combination of a 120A3A CSU module integrated with a DS1 circuit pack A 700A DS1 loopback jack must be installed with this device See Installing the 120A3A CSU for step by step installation procedures for the 120A3A CSU Note Re manufactured repaired ICSU units and any manufactured after May 7 2002 are marked as 120A3A Check for required components The ICSU package contains 120A3A
34. Begin Return to Task List Note In Norway Sweden Denmark and Finland the 127A can be used only with MCCs or DC powered SCCs 1 8 Mount the 127A vertically near the main distribution frame MDF The 127A case has tabs for screw mounting and cutouts for snap mounting the unit in a 89 type mounting bracket Attach a ground wire required between the 127A and the MDF ground terminal bar The wire must be green yellow and no smaller than 0 75 mm 18 AWG Strip both ends of an appropriate length of wire Insert one end of the wire into the MDF ground bar and secure Insert the other end into the screw connection in the end of the 127A and secure See 127A BALUN Coaxial Adapter Connect the H600 348 quad cable to the 4 DB 15 connectors provided on the 127A adapter Connect the transmit connectors to the connectors marked T and the receiver connectors to the connectors marked R Connect the other end of the cables to whatever connects to the network 127A BALUN Coaxial Adapter hidf127b 012301 Figure Notes 1 127A BALUN coaxial adapter 2 Connect to quad cable H600 348 or similar 3 BCN Connections to E1 network equipment 315 4 Single point ground connection 5 gt 0 75 mm 18 AWG ground wire to ground terminal at MDF Return to Task List Wiring Off Premises Stations TN1654 DS1 Converter Begin Return to Task List The cabling outside the building for off premises stations is
35. Direct connection between the switch and RFA No connection between the switch and RFA Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 4 and press Enter Wait until the system has completely reset before continuing Type change cabinet 1 and press Enter 107 New simplex and upgraded G3r only New or upgraded G3si only 1 In the Carrier Type column change the B carrier to processor and submit the form Type change system parameters duplication and press Enter Setthe Enable Operation of SPE Duplication field to y and submit the form Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 preserve license or reset system 3 no preserve license since the License File has been saved in translations and press Enter Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 and press Enter Wait until the system has completely reset before continuing If the system has IP endpoints registered
36. Echo offline commands No echo offline commands Auto answer on first ring or higher if specified in NVRAM Auto answer off Carrier detect normal Carrier detect override Load NVRAM defaults Load factory defaults Dumb mode Smart mode Return to Task List Connect the Ethernet Begin Return to Task List Connect the network cable to the ETHERNET connector on the TN802B external cable assembly You need a CAT5 or better cable for 100 Mbyte operation Install the Circuit Packs Begin Return to Task List A CAUTION When adding or replacing any hardware be sure to ground yourself against electrostatic discharge ESD by wearing a grounded wrist strap 250 Note The circuit packs are hot swappable so you do not need to power down the carrier to install them If you need to remove the TN802B IP Interface from the carrier at a later time shut down Windows NT first by pressing the recessed reset button on the faceplate see TN802B IP Interface faceplate of the TN802B IP Interface until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min it is safe to remove the circuit pack Note If replacing the existing TN799 circuit pack remove it first and replace it with the new one To properly seat the circuit pack push firmly on the front of the faceplate until the latch reaches the bottom rail of the carrier Then close the latch until it is fully engaged 1 I
37. LASER Product Cables Signals between the cabinets composing the system are carried by fiber optic cables To accomplish this the electronic signals at the connectors on the back of a cabinet must be converted into optical signals and optical signals from another cabinet must be converted back into electronic signals Opto electronic devices lightwave transceivers provide this interface The Avaya Media Gateway may contain a Class 1 LASER device if single mode fiber optic cable is connected to a remote Expansion Port Network EPN The LASER device operates within the following parameters Maximum Power Output 5 dBm Wavelength 1310 nm Mode Field Diameter 8 8 micrometers CLASS 1 LASER PRODUCT IEC 825 1993 A CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Contact your Avaya representative for more information Detailed Information See Optical Cross Connect Hardware for hardware details See Cleaning Fiber Optic Cables for cleaning instructions Optical Cross Connect Hardware Optical cross connects consist of Lightguide Interconnect Units LIUs with lightguide troughs in between them Typical Optical Lightguide Interconnect Unit shows a typical LIU One LIU terminates the incoming cables and the other terminates the outgoing cables A fiber optic patch cord or jumper is used to connect the circuits Circuits can be rerout
38. National Electrical Code grounding rules 23 383 Netherlands country code 113 network connecting ITS 237 network configuration changing network services 270 network jack on modem 325 night ringing testing 356 Nordic country code 114 off premises connections 162 off premises digital line circuit protectors 165 off premises protection 164 165 off premises station wiring 161 off premises stations 162 off premises stations wiring 316 onboard LAN connections testing 27 OPS trunks 298 299 300 301 302 optical connector couplings 388 optical cross connects 385 option settings 7400A and 7400B data modules 338 7400A data module 369 7400D data module 368 data module 365 AUDIX 377 option switch settings 365 order checking 18 out of building connections 162 out of building stations 162 outputs cable for control carrier 148 P packet bus support 295 packet bus support adding 219 220 221 224 packet data line pinouts 417 pass thru kit MCCI 391 password craft changing 114 patch cords installing and administering 72 PCOL trunks 296 pin designations Index auxiliary equipment 415 circuit packs 415 port circuit packs and telephones 144 159 pinout charts 415 pinout information port circuit packs and telephones 151 pinouts 415 417 auxiliary 415 circuit packs 415 DS1 H600 307 cable 424 lead and color designations 419 TN2185B circuit pack 421
39. Set TM Lead Table 3 Option 300 1200 2400 4800 9600 19200 AT CI Cl2 CH CH2 LL REMLOOP RL SIGLS DISC TM Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 OFF Note 2 Note 2 Note 2 Note 2 Note 2 Grant Note 2 ON Note 2 Administration procedures for Call Detail Recording CDR equipment are provided in Administrator s Guide for Avaya Communication Manager Attention Control Settings Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 ON Note 2 Note 2 Note 2 Note 2 Note 2 Grant Note 2 ON Note 2 572 Printer Used with Management Terminal CDR and Journal Printer Function Function Name 01 FORM LENGTH 02 LPI 03 CPI 04 LQ or NLQ 05 BUZZER 06 FONT 07 RESOLUTION 11 BUFFER 13 PW ON MODE 14 DIRECTION 15 BUFF FULL 16 P E 17 AUTO CARRIAGE RETURN CR 18 ZERO 375 Menu 09 01 01 01 01 02 01 02 01 01 02 01 01 01 Menu Status 11 6 10 LQ ON FONTCART 144 N LINE ON LINE B1 DIR 1 LF CR ACTIVE CR LF 0 Table 3 22 31 32 33 34 35 81 82 83 84 85 91 92 93 94 95 96 Table 4 AUTO LINE FEED 1 SKIP CHAR SET GO GL CHAR SET G1 GR CHAR SET G2 CHAR SET G3 OFF LINE STATE DSR REQUEST TO SEND RTS TIMING CD CLEAR TO SEND CTS OVER RUN DATA BIT PROTOCOL STOP BIT PARITY PBS matches connected device 572 Printer Used as System Printer Function 01 02 03 04 05 06 07 11 13 14 15 16
40. system is currently running tests on this circuit pack as part of background maintenance or demand testing This LED is also lit during initialization tests when a circuit pack is inserted or reset Busy The circuit pack is currently in use by the system Circuit Pack LEDs on Faceplate 127 fpdfled LUK 101596 Figure Notes 1 Alarm LED Red 2 Test LED Green 3 Busy LED Yellow 4 Latch Pin 5 Locking Lever TN1654 DS1 Converter Circuit Pack LEDs VODs 9 gt DH SS S D fpdfds1 LJK 101596 Figure Notes 1 Alarm LED Red 2 Test LED Green 3 Busy LED Yellow 4 STATUS LEDs 128 5 SPAN LEDs DS1 Converter Yellow LED Flashing States LED on LED off Condition 0 1 second 0 1 second Fiber out of frame or fiber loss of signal 0 5 second 0 5 In frame fiber channel down The fiber channel communicating between the DS1 Converter and the other fiber endpoint El or SNI is down 1 second 1 second In frame control channel down The control channel between the 2 DS1 Converters in the DS1 Converter complex is down 2 seconds 0 2 second No response from SPE The SPE is not acknowledging messages from the DS1 Converter or the communications link to the SPE is down solid on DS1 Converter active This is the normal state for an active DS1 Converter solid off DS1 Converter standby This is the normal state for a standby DS
41. 1 second of silence Cycle is repeated until disconnect which is forced after 24 hours Test Type 105 9 seconds of 1004 Hz tone at 16 dB 1 second of silence 9 seconds of 404 Hz tone at 16 dB 1 second of silence 9 seconds of 2804 Hz tone at 16 dB 30 seconds of silence 0 5 seconds of test progress tone 2225 Hz About 5 seconds of silence Forced disconnect Return to Task List Test the C LAN Connection Begin Return to Task List To test the external IP connections ping the C LAN circuit pack and ping a known computer connected to your network If everything is configured correctly the Result column on the Ping Results screen reads PASS If it reads ABORT verify the IP address information and check the connectivity including the cabling 1 To ping the C LAN server type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the TN799x C LAN circuit pack and UUCSS is the cabinet carrier and slot of the TN799x C LAN circuit pack 2 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of another computer beyond the gateway and UUCSS is the cabinet carrier and slot of the TN799x C LAN circuit pack 360 The TN799x C LAN circuit pack is now installed in the DEFINITY carrier and connected to the IP network Return to Task List Test Stratum 3 Clock if used Return to Task List These procedure
42. 2 Ensure that the new firmware image file is in the local staging area directory a Change the directory to the staging area cd your staging area b List the contents of the directory showing the most recent files last using dir od DOS or Is Itr UNIX Linux 345 Schedule a download to target s 3 Use FTP to copy the firmware image file s to the source a Type ping ip address where ip adaress is the IP address of the source board and press Enter to verify a communication link to the source board b Type ftp ip address and press Enter to provide the FTP interface with a link to the source c Log into the FTP session with the same ftologin and ftppassword that you set up earlier in Set up source circuit pack s file system on page 345 d Type binary and press Enter This requests that files be transferred in binary format A caution Files are corrupted during transfer if you do not specify binary a If you are self downloading to a TN2501AP VAL circuit pack type cd This command moves you from the announcement directory default for an FTP session on the VAL board to the root directory where firmware and other files reside This keeps the firmware image file separate from the announcement files b Type put filename ext and press Enter to copy the new firmware image file to the source directory in RAM c Type Is and press Enter to verify that the new firmware image file is on the circuit pack d
43. 2 Power Up AC Powered System or Power Up DC Powered System 3 Verify Messages on Terminal Install Translation Flash Memory Card Avaya DEFINITY Server si Begin Return to Task List 1 Insert the translation card into processor circuit pack 103 Return to Task List Install Removable Media MCC1 only Begin Return to Task List Insert the formatted removable media label facing left into the optical drive see TN2211 Optical Drive Note Make sure the formatted removable media is not write protected see Make sure the disk is not write protected before placing it into the optical drive TN2211 Optical Drive 4 Red 4 Green Lr O 4 Yellow ly is completed OK to remove yellow LED s are off DO NOT REMOVE until shutdown TN2211 OPTICAL DRIVE Less iato LJK 092799 hidfdsk KLC 091799 Figure Notes 1 Not write protected 2 Write protected Return to Task List 104 Power Up AC Powered System Begin Return to Task List 1 Set the associated circuit breakers on the AC power panel ON Note If the system is high or critical reliability power up the Expansion Port Network EPN first then the Processor Port Network PPN A ways power up the control cabinet ast 2 Atthe rear of each cabinet set the circuit breaker to ON This starts the system initialization and test Some red lights ma
44. 28 384 48 Js 19 29 39 49 Xs 20 30 40 50 iter 5 character board number cabinet 1 30 carrier A E slot 0 20 349 Monitor download progress If you are performing a C LAN distributed download enter a C LAN location as the source and 1 to 50 target locations where the target boards are all of the same type The following screen provides an example of a C LAN distributed download to 2 UDS1 circuit packs nd age firmware download Page 1 of FIRMWARE DOWNLOAD urce Board Location 01A04 nware Image File Name usdlv22r1 Target Board Code TN464 Suffix GP Firmware Vintage Schedule Download y Remove Image File After Successful Download y zart Date Time 10 08 2002 22 00 Stop Date Time 10 08 2002 22 30 get Target Target Target Target ation Location Location Location Location 01B04 11 21 3l 41 01B05 12 22 32 42 13 23 RER 43 14 24 34 44 LE 25 35 45 16 26 36 46 17 27 ST 47 18 28 38 48 19 29 39 49 20 30 40 BU ar 5 character board number cabinet 1 30 carrier A E slot 0 20 3 Press Enter to submit the schedule If you set the Schedule Download field to n the download starts as soon as you submit the schedule Note If you are scheduling firmware downloads for a circuit pack that is designated as primary secondary sync timing source for example TN464GP this procedure automatically redesignates a local timing source during the download After the download
45. 3 Type list configuration all and press Enter to verify that the system recognizes the TN2302AP circuit packs Return to Task List Perform Additional Administration Steps Begin Return to Task List 1 Administer the TN799DP C LAN if necessary Refer to the Administration for Network Connectivity for Avaya Communication Manager 2 Administer the IP Media Processor which is usually done remotely Call your service representative to start the process 245 3 Complete the administration and testing Refer to Perform Initial Administration Steps for C LAN and IP Media Processor and Test the External Connection to the LAN Installing a TN802B in Media Processor Mode Return to Task List To operate in MedPro mode you must install the TN802B IP Interface and if the system does not have one you must also install and administer a TN799DP C LAN circuit pack For C LAN administration refer to Administration for Network Connectivity for Avaya Communication Manager If you have existing TN802 IP Interface circuit packs you can upgrade them either by replacing the circuit pack with a TN802B or by downloading the TN802B firmware onto the circuit packs see Upgrade to TN802B R10 Task list Install the TN802B in Media Processor mode Prepare for Installation Check your shipment Connect the Cables for TN799x Connect the Cables for TN802B Connect the Modem Connect the Ethernet Install the Circuit Packs Administ
46. 6 Repeat the above steps for each CBC ground wire installed Coupled Bonding Conductor cbc gnd 1 PDH 062696 Figure Notes 1 25 Pair Tip amp Ring Cables to Cabinets 2 Coupled Bonding Conductor CBC Terminal Block 3 Tie Wraps 4 Cable Shield or Six Spare Pairs 5 Ground on Carbon Block Protector or Equivalent 6 Trunk Cable to Network Interface 7 10 AWG 25 2 5 mm Wire 8 To Network Cabinets 9 Battery Plant Ground Discharge Bar for Single Point Ground 10 Cross Connect Ground Block 11 Main Distribution Frame MDF 12 To Other Cross Connect Ground Blocks 13 Approved Ground 14 Coupled Bonding Conductor CBC 88 Return to Task List 89 90 Bring the System Online This section provides information about installing the system access software activating the system administering the system and powering a DEFINITY AUDIX system procedures for doing the installation and administration Information about Installing the Software Administering the System and Powering a DEFINITY AUDIX System About Accessing the System Administration Screens and Commands Administering the Circuit Packs DEFINITY AUDIX System Power Procedures Task List Setting up the PC and Administering the System oO Ff 10 11 12 Access the System Activate the System Administer the System If necessary administer the Circuit Packs See Administering the Circuit P
47. 67 8 A25D Cable 9 258A or BR2580A Adapter 10 Information Outlet 11 4 Pair Circuit DIW station cable D Inside Wire 3 Pair to 4 Pair Satellite Location Connectivity 9 9 Figure Notes 1 Part of MDF 2 3 Pair Connecting Blocks 3 Purple Field 4 White Field 5 Patch Cord or Cross Connect Jumpers 6 To System Cabinet 3 Pair Modularity 7 A25D Cable 3 Pair Circuits 8 B25A Cable 9 Connectorized staggered finger Multiple 25 Pair Cable 10 4 Pair Connecting Blocks 11 Blue Field 12 258A or BR2580A Adapter 13 Information Outlet 14 4 Pair Circuit DIW Station Cable D Inside Wire 15 Part of Satellite Location 16 4 Pair Circuits B25A Cable 3 Pair to 4 Pair Circuit Distribution and Connectivity 68 AKAKAA 1758533a CJL 031196 Figure Notes 1 Part of Main Distribution Frame MDF 2 3 Pair Connecting Blocks 3 Purple Field 4 Blue Field 5 Patch Cord or Cross Connect Jumpers 6 To System Cabinet 3 Pair Modularity 7 B25A Cable 8 3 Pair Circuits 9 356A Adapter 10 Information Outlet 11 3 Pair Circuit in 4 Pair Wire 12 DIW Station Cable D Inside Wire Voice and Data Terminals These voice and data terminals can connect to the system Voice and Data Terminals Type Multi button Electronic Telephone MET sets Voice 10 20 30 Button Analog Analog voice 500 2500 2554 2500 DMGC 2500YMGK S203A
48. 8 TN467 TN432 TN431 TN411B TN742 TN769 2 Wire Digital amp Analog Line 16 and 24 TN2149 TN2135 TN468B TN448 TN746 TN746B TN2181 TN2183 TN793 TN2793 Data Line amp Digital Line 4 Wire TN726B TN754B TN564B TN413 2 Wire Digital amp Analog Line 24 Ports TN2224 TN2214 TN793 TN2793 TN2214B TN2224B TN793B TN2793B Hybrid Line TN762 TN762B Multibutton Electronic Telephone MET TN735 Line 201 Equipment Classifications AUX Trunk Central Office Trunk Central Office Trunk 3 Wire Direct Inward Dialing Direct Inward Outward Dialing DID DIOD Trunk Tie Trunk DS1 Tie Trunk ISDN BRI Line 4 Wire ISDN BRI Line 2 Wire Packet Data Line Four Port DIOD Installing Circuit Packs Circuit Packs TN417 TN763 TN763D TN429 TN493 TN422 TN421 TN438B TN447 TN465C TN747B TN2138 TN2147C TN2148 TN2199 TN429 TN2139 TN459B TN436B TN753 TN2146 TN414 TN478 TN458 TN449 TN760D TN760C TN434 TN415 TN483 TN722 TN767 TN722B TN464F TN464GP TN556B TN2198 TN553 TN2184 Begin Return to Task List 1 Log in as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 202 2 when asked Suppress Alarm Origination during login 3 Install the circuit pack s into the carrier 4 Log off the system after all the additions and any required administration are complete Return to Task List Instal
49. 911 3_ 3 12_ emer n Return to Task List Changing the Route Patterns Begin Return to Task List 1 At the prompt type change route pattern number the route pattern to be changed in the example in Route Pattern form Page 1 Pattern Number 11 the route pattern is 11 and press Enter 2 On the Route Pattern screen Grp No field enter the CAMA trunk group number 3 In the FRL field enter 0 Note For the following step if the Central Office CO wants KP11ST as the dialed digit string then leave blank If the CO wants KP911ST then insert a 9 in the Inserted Digits field 4 Administer the Inserted Digits field if needed and press Enter 5 Atthe prompt type change route pattern number the route pattern to be changed in Route Pattern form Page 1 Pattern Number 12 the route pattern is 12 and press Enter 6 On the Route Pattern screen in Grp No field type the CAMA trunk group number and press Enter 7 In the FRL field type 0 Note For the following step if the Central Office CO wants KP911ST as the dialed digit string then leave blank If the CO wants KP11ST then delete one digit 291 8 Administer No Del Digits field if needed and press Enter Route Pattern form Page 1 Pattern Number 11 NH 1 Pattern Number 11 FRL NPA Pfx Hop Toll No Del Inserted 0 Mrk Lmt List Digits Digits Pag
50. AC mains 1 Connect a 6 AWG 40 16 wire to the PPN cabinet ground terminal block 2 Route the wire to the AC mains single point ground block and connect 3 Connect a 6 AWG 40 16 mm wire to each EPN s cabinet ground terminal block 4 Route the wire s to the AC mains single point ground block and connect 5 Connect a 6 AWG 40 wire to the DC battery cabinet and DC power cabinet 6 Route wires to the AC mains single point ground block and connect them Return to Task List Turn Circuit Breakers Off Begin Return to Task List The main circuit breaker on a DC powered PPN EPN cabinet is located on the front of the power distribution unit The circuit breakers on the rear of the power distribution unit control the individual carriers See Power Distribution Unit J58890CH for the location of the carrier breakers 1 Set the main circuit breaker to OFF 2 Set the carrier circuit breakers to OFF Power Distribution Unit J58890CH 38 V AM pedf010 KLC 020599 Figure Notes 1 Connect small battery holdover cable or temperature sensor cable from large battery cabinet to J20 2 Carrier Circuit Breakers 3 Ground Terminal Block 4 Connect 48 VDC Return 1 AWG 50 mm red cable here 5 Connect 48 VDC 1 AWG 50 mm black cable 6 1 AWG 50 mm 50 ft 15 2 m cable to large battery cabinet For cables greater than 50 ft 15 2 m contact your Avaya representative 7 Gro
51. If the suffix in the Code field does not have a P e g TN2302AP a firmware download is not possible 3 Look for the firmware vintage s in the vintage field of the target circuit pack s to see if a firmware download is needed 4 Record the UUCSS address in the Board Number field of each source and target circuit pack If a C LAN is the source make sure port 17 is assigned on that C LAN If it is not assigned administer the port 344 5 add data module UUC17 and press Enter For a self download to a VAL board make sure that port 33 is assigned on the VAL board If it is not assigned administer the port 6 Type add data module UUC33 and press Enter 7 Determine the IP address of the source circuit pack You can either ask the data systems administrator or type the following commands a Type display ip interfaces Find the source circuit pack s Slot location and write down its Node Name b Type display node names ip Find the source circuit pack s Node Name and write down its Address Set up source circuit pack s file system Before files can be copied to the source circuit pack you must set up a file system on the source circuit pack to accept the files 1 Log in using a superuser or services login and password 2 Type enable filesystem board UUCSS login ftplogin ftppassword where UUCSS is the location of the source circuit pack ftploginis any temporary login ID that you choose for this
52. J21 Connect external alarm cable here J18 Pin 6 RPO Pin 2 RPO psdf002 CJL 081596 alarm cable Remote Power Off Cable Connections Part 2 To Carriers AtoE Battery Cabinet Terminal TB1 l Cable Bar 26 Auxiliary Contacts in EPO Switch 0026_3 RBP 080196 Return to Task List Connect External Alarm Cable Begin Return to Task List 1 Plug the external alarm cable into the connector shown in External Alarm Cable Connection 2 Route the opposite end of the cable to the MDF The alarm cable is connected to the MDF later External Alarm Cable Connection 42 Carrier circuit breakers Connect RPO cable here J21 Connect external alarm cable here J18 Pin 6 RPO Pin 2 RPO External psdf002 CJL 081596 alarm cable Check Commercial Power and Connect AC Power Begin Return to Task List Before powering up the system check the AC power using a KS 20599 digital voltmeter DVM or equivalent 1 Set the DVM to the 250 volt range 2 Carefully measure the voltage between the hot and neutral side of the receptacle The neutral wire is white the hot wire is black 3 Verify the meter reads 106 to 128 VAC If not have a qualified electrician correct the problem 4 Measure the voltage between the neutral and ground side of the receptacle The ground wire is green 5 Verify the
53. Refer to the installation and usage documentation that comes with the Forum Personal Communications Manager components Add Port Circuit Packs Return to Task List When installing additional features or equipment it may be necessary to install additional port circuit packs See Circuit Packs and Circuit Modules by Code for a list of circuit packs This is a general procedure to use when adding features or equipment that require adding circuit packs A CAUTION Control circuit packs with white rectangles on the label cannot be removed or installed when the power is on The port circuit packs with gray rectangles on the label older version port circuit packs had purple labels can be removed or installed when the power is on Topics covered include e Circuit Pack and Auxiliary Equipment Classifications e Installing Circuit Packs Circuit Pack and Auxiliary Equipment Classifications Circuit packs are listed by these classifications e Analog Line 8 e 2 Wire Digital amp Analog Line 16 and 24 200 Data Line amp Digital Line 4 Wire 2 Wire Digital amp Analog Line 24 Ports Hybrid Line Multibutton Electronic Telephone MET Line AUX Trunk Central Office Trunk Central Office Trunk 3 Wire Direct Inward Dialing Direct Inward Outward Dialing DID DIOD Trunk Tie Trunk DS1 Tie Trunk ISDN BRI Line 4 Wire ISDN BRI Line 2 Wire Packet Data Line Four Port DIOD Equipment Classifications Circuit Packs Analog Line
54. Resolve Alarms ISDN PRI Begin Return to Task List 1 Examine the alarm log 2 Resolve any alarms that may exist using the Maintenance for Avaya MultiVantage DEFINITY Server documentation Save Translations ISDN PRI Begin Return to Task List 1 If the system is High or Critical Reliability type status system 1 and press Enter to verify that the system is in the active standby mode 2 Type save translation and press Enter This instructs the system to take all translation information in memory and write it to the translation cards 3 Update backup cards if necessary Adding CO FX WATS and PCOL Trunks Begin Return to Task List Each Central Office CO Foreign Exchange FX Wide Area Telecommunications Service WATS or Personal Central Office Line PCOL trunk is connected to 1 port of either an 8 port TN747 or to 1 of an assortment of non U S CO Trunk circuit packs 1 See Wiring Off Premises Stations 1654 DS1 Converter and install a CO trunk circuit pack in the assigned carrier slot if an additional circuit pack is required 2 Administer the Trunk Group screens listed under CO FX WATS or PCOL Trunk Group in Administrator s Guide for Avaya Communication Manager 3 Determine the port assignment of the trunk from the Trunk Group screen Return to Task List Adding DID Trunks Begin Return to Task List Each Direct Inward Dial DID trunk connects to 1 port of an 8 port TN753 or
55. Set the Clock Options Cable the Stratum 3 Clock Install the Stratum 3 Clock Wiring o ON Oo A WO Unpack and Inspect Stratum 3 Clock Cabinet Begin Return to Task List 1 Check the status of the SHOCKWATCH and or TILTWATCH indicators on the cardboard container If the container has been jarred or tilted beyond specifications the indicators are red indicating possible damage 2 Remove all packing material 3 Remove front door and rear screw on panels from the cabinet 4 Inspect the cabinet for damage Report any damage per local instructions Install and Position Stratum 3 Clock Cabinet Begin Return to Task List Check the location of the AC power receptacle The receptacle must be on a separately fused circuit that is not controlled by a wall switch It must be located within 10 ft 3 m of the cabinet and should be located outside the MDF area 1 Position the clock cabinet in the designated location 2 If earthquake protection is required skip to Install Earthquake Protection for SCC or Install Earthquake Protection for MCC 3 If earthquake protection is not required level the cabinets and adjust and lock the cabinet stabilizing bolts to keep the cabinet from moving Return to Task List 317 Connect AC Power to Stratum 3 Clock Cabinet Begin Return to Task List The clock cabinet requires a 120 VAC 15 amp receptacle The green wire ground provided by the receptacle is sufficient The
56. Terminating Resistor 208 3 Satellite Closet 4 Maximum Distance from S Interface Source to Work Location 1600 Feet 488 m 5 Maximum Distance From Terminating Resistor to Work Location 250 Feet 76 m 6 System Cabinet 7 Terminating Endpoint 1 8 Terminating Endpoint 2 9 Work Location 10 Maximum Distance from Information Outlet to Terminating Endpoint 33 Feet 10 m 11 Information Outlet Add Circuit Packs ISDN BRI Begin Return to Task List 1 Determine port assignments of circuit packs to be added 2 Install the appropriate circuit packs in assigned cabinet slot as required Required circuit packs TN2401 Processor circuit pack TN556 or TN2198 ISDN BRI line circuit pack TN570 B C Expansion Interface circuit pack if EPN present Return to Task List Install Cables ISDN BRI Begin Return to Task List Install the cables from the cabinet to the MDF as required Note A TN556 ISDN BRI requires an 8 port backplane cable terminator breakout connector aTN2198 ISDN BRI requires a 12 port backplane cable terminator Connect the 25 pair cable to the appropriate terminator Enter Added Translations ISDN BRI Begin Return to Task List Administer the required translation data using the forms listed under 7500D voice terminals and 8500 voice terminals in the Administrators Guide for Avaya Communication Manager Resolve Alarms Begin Return to Task List Examine
57. cable assembly if necessary 4 Turn off the modem and unplug it from the AC outlet 5 Disconnect the modem s RS232 port from the H600 512 external cable assembly From the rear of the cabinet 6 Disconnect the amphenol connector on the existing external cable assembly from the backplane connector corresponding to the TN802 circuit pack 7 Connect the amphenol connector of the TN2302AP Amphenol adapter to the backplane connector corresponding to the slot selected for the TN2302AP circuit pack Note The TN802 occupied 3 slots and the cable was connected to the rightmost backplane slot For convenience use the same rightmost slot vacated by the TN802 circuit pack for the TN2302AP circuit pack 8 Connect the network cable to the Ethernet connector on the TN2302AP Amphenol adapter Return to Task List Install the Circuit Packs Begin Return to Task List 1 If replacing the TN799 circuit pack install the TN799DP circuit pack in the slot vacated by the TN799 circuit pack 2 For convenience install the TN2302AP circuit pack in the rightmost slot vacated by the TN802 The other 2 slots are now available for other circuit packs When you plug in the TN2302AP IP Media Processor the circuit pack starts to boot The RED LED stays on until an IP address is assigned to the circuit pack 242 3 Type list configuration all and press Enter to verify that the system recognizes the TN2302AP circuit packs Administer and Test
58. first Sunday or after October 25 at 3 00 3 Start first on or after at Stop first on or after at 4 Start first on or after at Stop first on or after at 5 Start first on or after at Stop first on or after at 6 Start first on or after at Stop first on or after at 7 Start first on or after at Stop first on or after at E Return to Task List Set Date and Time Begin Return to Task List 1 2 Type set time and press Enter Verify the screen displays the Date and Time screen See Typical Date and lime Screen The cursor is positioned on the Day of the Week field Type the day of the week in English Sunday through Saturday and press Tab to move to next field See English Day of the Week Names for English day of the week names The cursor is positioned on the Month field Type the current month in English January through December See English Month Names for English month names After the month is entered press Tab to move to next field The cursor is positioned on the Day of the Month field Type the day of month 1 through 31 and press Tab to move to the next field The cursor is positioned on the Year field Type the current year and press Tab to move to the next field The cursor is positioned on the Hour field Type the current hour for a 24 hour clock See Conversion to 24 Hour Clock Press Tab to move to the next field The cursor is positioned on t
59. receptacles One 258A BR2580A adapter is required for each 25 pair station cable containing 4 pair station circuits One 356A adapter is required for each 25 pair station cable containing 3 pair station circuits Hardware requirements are the same as for the equipment room Sizing 4 Pair Station Cables Use the scale of the floor plan to determine the approximate length of the station cables required per the standard SYSTIMAX wiring concepts 71 Sizing 25 Pair and Multiple 25 Pair Station Cables Use the scale of the floor plan to determine the approximate length of each 25 pair station cable The cables must be selected and properly sized to make maximum use of the hardware at the equipment room or satellite location Use 25 pair B25A cables to connect adapters directly to the MDF or satellite location Staggered finger cables equipped with factory installed 25 pair connectors at both ends should be used when multiple 25 pair cables are used between the equipment room or satellite location and the adapters B25A cables are required at the equipment room or satellite location to connect the staggered finger cables to the 110 type terminal blocks Use the following information to determine the cable size cable pairs required for either 3 pair or 4 pair circuits Note the length and size on the floor plan to aid in the ordering and installation of the station cables 3 Pair Station Cable Circuits To determine the size of station
60. reporting circuit pack damage or discrepancies 19 reporting damage 18 reseating TN2501AP VAL board 351 returning equipment ringing testing 356 routing cables to MDF 57 Russia country code 113 S safety instructions 1145B power supply 186 1151A1 and 1151A2 power supply 196 Saudi Arabia country code 113 save translation 119 120 210 219 220 224 229 296 299 302 schedule for firmware download 346 350 screens administration introduction 92 selector console 156 selector console testing 356 self download procedure 342 server name assigning 264 service states checking 129 setting bit rate 380 line impedance 380 433 Index setting 7400B data module options 102 setting data module operating mode 102 setting data module to DCE mode 101 setting date and time 116 setting daylight savings rules 115 shadowing link testing 133 shipping errors 19 shipping packing lists 18 SHOCKWATCH indicators 18 shorting cable 31 signaling leads DC power 378 Singapore country code 113 single phase 240VAC 24 site locations adapters 61 sneak current protection 56 sneak current protection installing 85 sneak current protectors off premises connections 164 165 sneak fuse panel space requirements 60 sneak fuse panels 56 60 sneak fuse panels installing 85 South Africa country code 114 space requirements 110 type hardware 60 cable slack manager 60 sneak fuse panels 60 Spai
61. ring indefinitely Therefore the initialization string must contain the following ASCII string to set the No Answer Timer to the maximum value 57 255 The internal modem must have this parameter disabled or set to at least 255 seconds This is a non administrable parameter For the modem connection this parameter is the first initialization string to be transmitted to the modem This field is visible on the administration form in display mode only The new field is set to S7 255 This hardcoded constant can be overridden for type approval applications specifically in the United Kingdom and other Western European nations by the use of the Misc Init Param field S7 255 Return to Task List Printer Option Settings Return to Task List Printers can be used with a management terminal as journal printers for the hospitality feature and also as an output device for Call Detail Recording CDR A572 printer can function as a CDR device system printer or journal printer The options are set with function keys rather than DIP switches Control Panel for 572 Printer shows the arrangement of the function keys on the printer control panel 1 Load the printer with paper and turn the power off Callout 1 2 Simultaneously press and hold the Print Quality and On Line buttons Press the Power On button Release all three buttons The printer is now in set up mode and it prints current settings 371 3 If the printer is used with
62. s network Cable Connection for C LAN cydflan2 EWS 101398 Figure Notes 1 259A Connector 2 DW8A Cable 3 Hub or IP Switch TN799x Pinout Backplane Pin 25 Pair Wire Color Lead Name Peripheral Connector Pin 103 White Orange TD 27 003 Orange White TD 2 104 White Green RD 28 004 Green White RD 3 Return to Task List Add Circuit Packs Add DCS Begin Return to Task List 226 New Duplicated G3r installations only Determine the port assignments of the circuit packs to be added If there are no available port slots in the processor cabinet for the C LAN circuit pack place it in an EPN cabinet port slot A CAUTION When adding or replacing any hardware be sure to ground yourself against electrostatic discharge ESD by wearing a grounded wrist strap Note The TN799x circuit pack is hot swappable so you do not need to power down the carrier to install it Insert the TN799x circuit pack into the port slot identified earlier Return to Task List Test the External Connection to the LAN Add DCS Begin Return to Task List To test the external IP connections ping the C LAN server and ping a known computer connected to your network If everything is configured correctly the Result column on the Ping Results screen reads pass If it reads abort verify the IP address information and check the connectivity including the cabling 1 Type ping ip address nnn nnn nnn nnn board UUCSS and
63. that can be assigned to the IP Media Processor server You also need the subnet mask and default gateway Note The customer provides the IP address subnet mask and gateway address See Check your shipment to make sure you have everything you need to start the installation procedure Return to Task List Check your shipment Begin Return to Task List When your Avaya Media Gateway IP Solutions order arrives at your site check the contents see Required Hardware 1 Inspect the shipping carton for damage before opening it If the box is damaged do not open it Inform the shipping company and ask for instructions on filing a claim 2 If the box is undamaged check the contents against the packing slip Check the condition of each component and note any damage or shortages on the packing slip The carton should contain the items in Required Hardware for each TN2302AP Media Processor ordered 3 Read and follow any directions inserted into the package by the factory Required Hardware Description Quantity TN799x C LAN circuit pack 11 TN2302AP IP Media Processor 1 TN2302AP Amphenol Adapter 1 ADPTR 259A connector 1 1 One TN799x supports more than one TN2302AP 2 The adapter has an amphenol connector on one side and an RJ45 connector on the other for connecting to the LAN See TN2302AP Amphenol Adapter Note The customer must provide CAT5 or better cable for each TN2302AP TN2302AP Amphenol Adapter
64. trunks can provide emergency transfer capability The 808A Emergency Transfer Panel provides emergency trunk bypass or power fail transfer for up to five incoming Central Office CO trunk loops to five selected station sets The 808A equipment s Ringer Equivalency Number REN is 1 0A At the Main Distribution Frame MDF the unit is controlled by a connection to a yellow terminal row connecting block in the trunk auxiliary field The unit is controlled by 48 VDC from the EM TRANS RELAY PWR terminals There are seven EM TRANS RELAY PWR terminal pairs that allow powering of up to seven transfer units Should power be restored to the relays while a call connected through the 808A is in progress the 808A maintains the connection until the user goes on hook Each 808A can handle up to five Central Office CO trunks Return to Task List 168 808A Emergency Transfer Panel and Telephone Installation Examples Return to Task List 808A Emergency Transfer Panel shows a typical 808A Emergency Transfer Panel The 808A connects to the Main Distribution Frame MDF with B25A or A25B cable The panel can be installed on any mounting frame in either a vertical or horizontal position The housing has ears for screw mounting and cutouts for snap mounting the unit in an 89 type mounting bracket See 808A Emergency Transfer Panel Mounting Task List Typical Emergency Transfer Panel and Telephone Installation e Install the 808A Emergency Tran
65. you must either replace it with a TN802B circuit pack or upgrade the existing TN802 V3 or later circuit pack to operate in MedPro mode Also to operate in the MedPro mode the Avaya Media Gateway switch must be R10 or later Note The TN802 IP Interface must be V3 or later to upgrade to TN802B To upgrade the TN802 to a TN802B you need the following hardware Monitor keyboard and mouse to access the IP Interface s Windows NT environment or pBCANYWHERE software 10 Mbyte SanDisk PCMCIA flashcard loaded with the MedPro NT Application Install Wizard TN802B label The upgrade adds or modifies the following directories or files on your computer s hard drive c dolan c mapd dnid medpro img c mapd dnid tmp img Task list Upgrade a TN802 to a TN802B Perform these tasks in order 1 Connect the Monitor Keyboard and Mouse 2 Upgrade IP trunks R7 to H 323 trunks 272 3 Upgrade to TN802B R10 4 Verify Circuit Packs Connect the Monitor Keyboard and Mouse Begin Return to Task List 1 Attach a VGA monitor to the VGA connector of the TN802 IP Interface external cable assembly Attach the keyboard to the KEYBOARD connector of the external cable assembly Attach the mouse to the MOUSE connector of the external cable assembly Plug the monitor into an AC power receptacle and turn it on ao A oO ND If upgrading locally reboot Windows NT by pressing the recessed reset button on the faceplate see T
66. 02 Suffix A A Date 09 13 02 05 06 02 Timestamp 10 30 50 12 42 18 CRC Checksum Good Good Active Image Yes No Reboot Image Yes No E 2 Check the Active Image field in the Image 1 and Image 2 columns to see where the active image resides 3 Check the Date and Timestamp fields to determine whether to revert back to a previous image In the following example we are reverting back to Image 2 because it has the older date and time stamp Note In most cases the image with the more recent date and time stamp is the new firmware image file 353 4 set boot image board UUCSS image 1 2 and press Enter Example set boot image board 1C07 image 2 The system responds with Command Successfully Completed 5 Type get boot image UUCSS and press Enter to check the status of the firmware images on the target circuit pack set boot image 1C07 ES DISPLAY FIRMWARE IMAGE S Image 1 Image 2 Board Type TN2501 TN2501 FW Vintage 02 01 HW Signature 02 02 Suffix A A Date 09 13 02 05 06 02 Timestamp 10 30 50 12 42 18 CRC Checksum Good Good Active Image Yes No Image No Yes 2 Note that the values in the Reboot Image field has changed Note If a TN799C DP C LAN or TN2305 VAL circuit pack reseat them to activate the new firmware image Go to Reseat VAL circuit pack on page 351 6 Type get boot image UUCSS to check the status of the firmware images on the target circuit pac
67. 1 and press Enter to verify that the system is in the active standby mode 2 Type save translation and press Enter This instructs the system to take all translation information in memory and write it to the translation cards 3 If the system contains a TN750 B C Announcement circuit pack type restore announcements and press Enter 4 Update backup cards if necessary Add DCS Interface Return to Task List 224 This section includes general information on adding the DCS interface and the Task List Add DCS Systems in a Distributed Communications System DCS network are interconnected by both tie trunks for voice communications and data links for control and transparent feature information These data links also called DCS signaling links support the feature transparency Various subsets depending on the specific configuration of DS1 Interface circuit packs provide the voice communications interface The TN799x Control LAN C LAN circuit pack provides the data link interface between the processor and the physical signaling link In some configurations the TN799x passes the signaling information over a separate ethernet network usually via a hub to adjuncts applications such as CMS Intuity and DCS Networking The C LAN circuit pack has one Ethernet connection and up to 16 DSO physical interfaces for PPP connections In addition to the ethernet functionality C LAN extends the ISDN capabilities by providing packet bus
68. 100 Mb ethernet interface allowing announcement and firmware file portability over your LAN FTP server functions e supports wav announcement files see Important File Specifications works in r si csi DEFINITY ONE and Avaya IP600 models Voice Announcement over LAN VAL requires that announcement files are in the following wav formats e CCITT A Law or CCITT u Law companding format do not use PCM e 8KHz sample rate 8 bit resolution bits per sample Mono channels 1 You must convert other wave wav file formats to those listed above Telephone access creates the correct file formats Save and Restore Recorded Announcements A CAUTION If the yellow LED is on do not remove the circuit pack This will corrupt the announcement data The syntax for saving from any TN750 circuit pack is save announcements from PCSS and press Enter Where P is the port network number 1 for PPN and 2 4 for EPN C is the carrier designation A B C D or E and SS is the number of the slot in which the circuit pack resides 01 to 21 The syntax for restoring to a TN750C circuit pack is restore announcements disk removable media to PCSS and press Enter Where P is the port network number 1 for PPN and 2 4 for EPN C is the carrier designation A B C D or E and SS is the number of the slot in which the circuit pack resides 01 to 21 When executing a 213 restore command and there are existing anno
69. 254 change circuit packs Page 1 of 5 CIRCUIT PACKS Cabinet 1 Carrier A Slot Code 01 TN754 02 TN758 03 TN2144 04 TN746 B 05 06 TN771 C 07 TN464 F 08 TN2140 09 TN767 E 10 TN799 B Carrier Type processor Sf Mode Name Slot Code Sf Mode Name 11 MEDPRO RESERVED IP DIGITAL LINE 12 MEDPRO RESERVED IP POOLED MODEM 13 TN802 B MAPD BOARD ANALOG LINE 14 ANALOG LINE 15 16 MAINTENANCE TEST DS1 INTERFACE E amp M TIE TRUNK DS1 INTERFACE CONTROL LAN indicates circuit pack conflict IP Interfaces Screen 1 change ip interfaces Page 1 of 2 Network regions are interconnected n En abled Type C LAN 01A09 TN799 clan al 255 255 255 0 192 168 1 100 1 MEDPRO 01A13 TN802 B med al 255 255 255 0 192 168 1 21 1 n 0BUBDUDDBDSUPBDBODBDDBDSDX Net Slot Code Sfx Node Name Subnet Mask Bcast Gway Addr Rgn 255 255 255 0 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 Return to Task List Test the External Connection to the LAN Begin Return to Task List To test the external IP connections ping the IP Interface server and ping a known computer connected to your network If everything is configured correctly the Result column on the Ping Results screen reads pass If it reads abort verify the IP address information and check the connectivity includ
70. 43 E El interface 380 earthquake protection MCC 21 22 echo cancellation 230 TN2464BP 230 TN464GP 230 EIA 374 EIA port 374 electromagnetic compatibility standards 3 Electronic Industries Association 374 emergency transfer panel installing 170 emergency transfer telephones 175 176 emergency transfer units 168 emergency transfer testing 358 EPN expansion interface exchange testing 136 TDM testing 135 tone clock interchange testing 135 tone clock testing 135 EPN cabinets cabinet location 19 EPN tests 125 EPN connect external modem 328 equipment room cabling labels 57 equipment room cable routing 57 equipment room station circuit distribution from 65 expanded power distribution unit 191 expansion interface circuit packs testing 134 expansion interface exchange testing 136 expansion links service state 129 external alarm cable connecting 42 external alarm indicators connecting 156 external alarm wiring 143 157 external modem COMSPHERE 370 external ringing 177 external ringing testing 356 F Feature Access Code form 280 Fiber Link Administration form 403 basic fields 405 DS1 converter instructions 411 412 413 DS1C converter instructions 407 duplication administration fields 405 PNC duplication 404 fiber optic multimode transceiver 380 fiber optic cable 403 critical reliability CSS system 47 direct connect systems 44 Fiber Link Administration form 403
71. Any of the remaining three circuits on the processor interface to be used to support AUDIX must be connected through a 7400D Data Module serving as the interface link for AUDIX The option settings are shown in Data Module Settings for DEFINITY AUDIX Data Module Settings for DEFINITY AUDIX Return to Task List DIP Switch 1 Setting 9600 ON SYNC ON INT ON AANS ON All Other Switches OFF 377 TN760D Tie Trunk Circuit Pack Option Settings Return to Task List The TN760D Tie Trunk circuit pack interfaces between the tie trunks and the Time Division Multiplex TDM bus Two tip and ring pairs form a 4 wire analog transmission line An E and M pair is used for signaling and are DC signaling leads used for call setup The E lead receives signals from the tie trunk and the M lead transmits signals to the tie trunk To choose the preferred signaling format Signaling Formats for TN760D and Signaling Type Summary set the switches on the TN760D and administer the port per TN760D Tie Trunk Circuit Pack Component Side and TN760D Option Switch Settings and Administration A CAUTION To prevent damage from static electricity wear an EMC wrist strap when handling circuit packs or other components Signaling Formats for TN760D Mode Type E amp M Type Standard unprotected E amp M Type Compatible unprotected Protected Type Compatible Type Standard Simplex Type V E amp M Type V E amp M Type V Revised Signaling Type
72. Attendant Console and connect the modular cord to the information outlet 2 Install labels per the Attendant Console form and the Display Module form assignments 3 Install a Digital Line circuit pack in the assigned carrier slot if an additional circuit pack is required 4 Administer the forms listed in Attendant Console in Administrator s Guide for Avaya Communication Manager 302C1 Console phdf302 KLC 101196 Return to Task List Install the 26 1 Selector Console Begin Return to Task List 1 Connect the supplied 3 foot 0 9 m D8AC cable to the modular jack on the bottom of the 26B1 Selector Console 2 Route the cable to the attendant console and connect to the DXS BLF jack 3 Attach labels according to the Attendant Console form 4 Administer the console using Administrator s Guide for Avaya Communication Manager Return to Task List Connect External Alarm Indicators and Auxiliary Power Begin Return to Task List Alarms can be generated on adjunct equipment sent to the DEFINITY System and recorded and reported as external alarms A typical major alarm input is from an Uninterruptible Power Supply UPS The system provides a relay contact that can operate a customer provided alarm such as a light or bell The circuitry and power source are customer provided The alarm device must not exceed a rating of more than 100 Volts at 0 75 Amp 1 Connect 1 major and 1 minor alarm input pair to the tru
73. CD ROM drive required to install Avaya Site Administration from CD Available hard disk space A minimum of 100 MB free hard disk space is required The requirement for disk space depends on the size and number of configuration data sets 96 Minimum requirements to run Avaya Site Administration Printer port Standard PC or network printer port is required for connecting to a printer to produce station button labels Network adapter May be required for network access to AUDIX and other network connected systems Free serial ports One free serial port capable of 9600 bps operation is required for a connection to each serial device ADU modem data module or direct connection to a Avaya Media Gateway We recommend that PCs have at least a 16550A UART or 16550A UART simulator capable of 56 kbps DTE speed connections USB and internal modems should emulate this hardware A second serial port is required for simultaneous connection to AUDIX through a serial connection Return to Task List Connect Directly to the Avaya Media Gateway Begin Return to Task List You can connect directly from the PC if it is 50 ft 15 m or less from the Avaya Media Gateway Connect the equipment as shown in A typical direct connection Also see PC connections by platform A CAUTION For a DC powered system install an EIA 116A Isolator in series between the cable and the TERM DOT or Terminal Active connector A typical direct
74. Connector Block 8 Printed Circuit Board Mounted on Standard 110A or 100APR Block Typical Installation of Terminating Resistor Block Using Multipoint Connection 205 T RT1R1 9 9 Figure Notes 1 Part of Terminating Resistor Block 2 White or Purple Field 3 Part of 4 Pair Blue Field 4 From ISDN T interface Circuit 2 Pair 5 To ISDN S T interface Terminals 6 2 Pair Cross Connect 7 Basic Multi point Option 8 2 Pair Cross Connect 9 4 Pair Horizontal Cables 10 Row A 11 Row B 12 Row C Installing Multipoint Adapters Begin Multipoint adapters are used to provide signal fanout of the T interface Fanout can be performed at the work station by the BR851 B Adapter T Adapter or the 367A Adapter These adapters support more than one ISDN terminal per horizontal 4 pair D inside wire DIW To support multiple horizontal runs fanout must be performed in the satellite closet by a MDF with multiple common rows The 110RA1 12 provides fanout for two horizontal runs and contains the 100 Ohm terminating resistor This can be used for basic multipoint or point to point with terminating resistor in the closet Other fanout blocks include the 110AB1 025M and the 110AB1 050M 206 BR851 B Adapter T Adapter The BR851 B supports two terminals on one multi point BRI at the work station It is a T shaped device used to fanou
75. G3r G3si G3csi chapter of the RFA Job Aid deliver the License File to your laptop PC 2 Open the License Installation Tool LIT application at your laptop PC 3 Use the LIT instructions to add a switch connection profile to the tool 4 Use the LIT instructions to install the License File on the switch 5 f the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints A CAUTION Return to Task List 223 Test the Packet Bus and C LAN Circuit Pack Packet Bus Support Begin Return to Task List Type test packet port network 1 long and press Enter For more detail about these tests refer to the test pkt command section in the appropriate maintenance book Resolve Alarms Packet Bus Support Begin Return to Task List 1 Type display alarms and press Enter 2 Examine the alarm log 3 Resolve alarms using the appropriate maintenance book Enable Scheduled Maintenance and Alarm Notification Packet Bus Support Begin Return to Task List 1 Type change system parameters maintenance and press Enter 2 Enable the scheduled daily maintenance 3 If you changed the Start Time or Stop Time field change it back to the original time 4 Re enable alarm notification 5 Save Translations Packet Bus Support Begin Return to Task List 1 If the system is high or critical reliability type status system
76. List DS1 Tie Trunk Example Return to Task List Digital Signal Level 1 DS1 tie trunks provide a 1 544 Mbps T1 or 2 048 Mbps E1 digital data service between two collocated systems or between the system and a data network See these examples 146 Collocated DS1 Tie Trunks DS1 Tie Trunks Using T1 Channel Service Unit For cable descriptions see DS1 Cables Pinout of C6F Cable Collocated DS1 Tie Trunks Two DS1 tie trunk circuit packs can be in collocated systems A 051 Tie Trunk circuit pack in one system can be connected to a DS1 in another system A C6D cable can be used if the distance is less than 50 feet 15 2 m If the distance is between 50 feet 15 2 m and 1310 feet 399 m use a C6E cable Note The maximum distance between cabinets is 1310 feet 399 3 m DS1 Tie Trunks Using T1 Channel Service Unit The T1 Channel Service Unit CSU interfaces the 051 tie trunks with the 1 544 Mbps digital facility Connect the DS1 tie trunk to a T1 CSU See Typical Connections to Channel Service Unit Note A 3150 CSU is shown a 120A Integrated CSU ICSU may be used Contact your Avaya representative for maximum cabling distances for the 31xx series CSU or the 120A ICSU Typical Connections to Channel Service Unit 0012 1 RBP 062696 Figure Notes 1 Connector to DS1 Interface Circuit Pack 2 C6C Cable For Distances Over 50 Feet 15 24 m Use C6E Cable s
77. Member Assignments form page 5 i Page 5 of 11 TRUNK GROUP Administered Members min max 1 2 GROUP MEMBER ASSIGNMENTS Total Administered Members 2 Port Code Sfx Name 1 O1CO401 TN429 C 2 01C0402 TN429 3 4 5 6 as 8 9 10 11 12 Return to Task List Changing the Feature Access Code Begin Return to Task List 1 At the prompt type change feature access code and press Enter The Feature Access Code FAC form page 1 appears 2 Inthe Auto Route Selection ARS Access Code 1 field administer the ARS access code in the example above type 9 and press Enter must match dial plan Feature Access Code FAC form page 1 289 1 me FEATURE ACCESS CODE FAC Abbreviated Dialing Listl Access Abbreviated Dialing List2 Access Abbreviated Dialing List3 Access Abbreviated Dial Prgm Group List Access Announcement Access Answer Back Access Auto Alternate Routing AAR Access Code Code Code Code Code Code Code Auto Route Selection ARS Access Code 1 9 Access Code 2 Automatic Callback Activation Deactivation Call Forwarding Activation Busy DA Call Park Access Call Pickup Access CAS Remote Hold Answer Hold Unhold Access CDR Account Code Access Change Coverage Data Origination Access Data Privacy Access Directed Call Pickup Access Emergency Access To Attendant Access Extended Call Fwd Activate Busy D A Facility Test Calls Access Flas
78. PNC A PNC Board Location Board Location Board Type xxx Board Type xxx Return to Task List Duplicated Fiber Link Administration Return to Task List 405 Fiber Link Administration form page 1 of 3 shows the fields available when duplication is enabled The following fields appear when Administration of PNC Duplication is enabled on the System Parameters Customer Options form Fiber Link Display only field From the command line enter a 1 to 3 digit number to uniquely identify a switch connection in the system and its duplicate if appropriate Is one endpoint remoted via DS1 Converter Complex Enter yes to specify that a DS1 converter complex is used to remote one endpoint If yes is entered A PNC and B PNC 051 Converter DS1CONV Attributes must be administered on Pages 2 and 3 respectively of the form Board Location Enter the cabinet carrier and slot that identifies the physical location of a circuit pack in the first endpoint of the duplicate fiber link Endpoint 1 s duplicate along with Endpoint 2 s duplicate make up the duplicate fiber link called the B PNC link Board Type Display only field showing the type of circuit pack in Endpoint 1 The circuit pack type in Endpoint 1 A PNC and Endpoint 1 B PNC must be the same DS1CONV Board Location Enter the cabinet carrier and slot that identifies the physical location of DS1 Converter circuit pack in the first endpoint of
79. Panel Sneak Current Protector 507B sneak CJL 032096 Figure Notes 1 Sneak Fuse Panel 2 25 Pair Male Connector In 3 25 Pair Female Connector Out 4 220029 Fuses Inside Panel Use small screwdriver to pry top cover off 86 Sneak Fuse Connector Pinout Connector Pin Pair Fuse Numbers Number 26 1 1 27 2 2 28 3 3 29 4 4 30 5 5 31 6 6 32 7 7 33 8 8 34 9 9 35 10 10 36 11 11 37 12 12 38 13 13 39 14 14 40 15 15 41 16 16 42 17 17 43 18 18 44 19 19 45 20 20 46 21 21 47 22 22 48 23 23 49 34 24 50 25 25 Return to Task List Install Coupled Bonding Conductor Begin Return to Task List The Coupled Bonding Conductor CBC connects to the single point ground block and runs adjacent to pairs in an associated telecommunications cable The mutual coupling between the bonding conductor and the pairs reduces potential differences in terminating equipment 1 Cut a 10 AWG 25 2 5 mm wire long enough to reach from the system s single point ground block or DC power cabinet Ground Discharge Bar to the MDF CBC block 87 2 Connect one end of the 10 AWG 25 2 5 mm wire to the single point ground block or Ground Discharge Bar 3 Route the wire next to the 25 pair cables connecting to the trunk auxiliary purple field 4 Tie wrap the 10 AWG 25 2 5 mm wire to the 25 pair cables 5 Connect the 10 AWG 25 2 5 mm wire to the CBC ground block
80. Power Connections o s e SaaS Sa cydfadjn KLC 020599 Figure Notes 1 Typical Display Telephone 2 Individual Power Supply Such as 1151A1 or 1151A2 3 Information Outlet Modular Jack 4 4 Pair D Inside Wire DIW Cable 5 Satellite Site or Adapter Location 6 25 Pair D Inside Wire DIW Cable 7 Station Side of Main Distribution Frame MDF 8 100P6A Patch Cord or Jumpers 9 System Side of Main Distribution Frame MDF 10 25 Pair Cable to System Cabinet Analog Line Circuit Pack 11 Equipment Room 12 Satellite Location 13 Work Location 14 Bulk Power Supply Such as 1145B 167 Connections at Trunk Auxiliary Field 1758482b RBP 062696 Figure Notes 1 To Network Interface Facility 2 To Control Carrier Auxiliary Connector 3 One Pair of Wires 4 Twenty fifth Pair of RJ21X Network Interface Jack Return to Task List Emergency Transfer Units and Associated Telephones Return to Task List An 808A Emergency Transfer Panel mounted next to the trunk auxiliary field provides emergency transfer capability You can use 500 and 2500 series analog telephones either for emergency transfer or as normal extensions For emergency transfer connect the phones directly to the 808A for normal extensions wire them through the 808A Analog Central Office CO and Wide Area Telecommunications Service WATS
81. RETURN CR ZERO AUTO LINE FEED 1 SKIP CHAR SET GO GL CHAR SET G1 GR CHAR SET G2 CHAR SET G3 OFF LINE STATE DSR REQUEST TO SEND RTS TIMING CD CLEAR TO SEND CTS OVER RUN DATA BIT PROTOCOL STOP BIT PARITY PBS matches connected device 572 Printer Used as System Printer Function 01 02 03 04 05 06 07 11 13 14 15 16 17 18 Function Name FORM LENGTH LPI CPI LQ or NLQ BUZZER FONT RESOLUTION BUFFER PW ON MODE DIRECTION BUFF FULL P E AUTO CARRIAGE RETURN CR ZERO 373 01 01 01 01 02 01 03 07 01 02 01 02 02 02 02 03 01 01 01 Menu 09 01 01 01 01 02 01 02 01 01 02 01 01 01 CR LF 0 CR ONLY OFF USA UK GE LINE DRAWING ALL RECEIVE OFF RTS OFF OFF 256 8 XON XOFF 1 9600 Menu Status 11 6 10 LQ ON FONTCART 144 N LINE ON LINE B1 DIR 1 LF CR ACTIVE CR LF 0 Table 2 572 Printer Used as System Printer Function 22 31 32 33 34 35 81 82 83 84 85 91 92 93 94 95 96 Function Name AUTO LINE FEED 1 SKIP CHAR SET GO GL CHAR SET G1 GR CHAR SET G2 CHAR SET G3 OFF LINE STATE DSR REQUEST TO SEND RTS TIMING CD CLEAR TO SEND CTS OVER RUN DATA BIT PROTOCOL STOP BIT PARITY PBS Return to Task List Call Detail Recording Option Settings Return to Task List Menu 01 01 02 01 03 07 01 02 01 02 02 02 02 03
82. Stratum 3 Clock for instructions 5 Check Circuit Packs 6 Correct Shipping Errors Perform these tasks to install the cabinets 7 Position the PPN Cabinet 8 Position the EPN Cabinets 9 Position the Auxiliary Cabinet Optional and Install Auxiliary Cabinet Equipment 10 If required Install Earthquake Protection for MCC1 WARNING If the approved ground or approved floor ground can only be accessed inside a dedicated power equipment room then connections to this ground should be made by a licensed electrician See Approved Grounds for more information 11 Connect AC Power and Ground or Connect DC Power and Ground These tasks have their own task lists 12 Connect Remote Power Off Cable 13 Connect External Alarm Cable 14 Check Commercial Power and Connect AC Power 15 Verify Fiber Optic Duplication Interface Cabling TN792 port networks 16 Connect Fiber Optic Interconnect Cabling Check Customer s Order Begin Return to Task List 1 Check the customer s order and the shipping packing lists to confirm all equipment is present 2 Check the system adjuncts for damage and report all damage according to local shipping instructions 3 If any equipment is missing report the information to your Avaya representative Unpack and Inspect Cabinets Begin Return to Task List A CAUTION A cabinet may weigh as much as 800 Ib 363 kg and may be top heavy Use extreme caution 1 Check the status of the SHOCKWATCH and
83. Summary Signaling Transmit M Lead Receive E Lead Type On Hook Off Hook On Hook Off Hook Type Standard grd bat open bat grd Compatible opent bat grd grd opent bat Type V openi bat grd open grd Type V Reversed grd open grd open 1 An open circuit is preferred instead of battery voltage TN760D Tie Trunk Circuit Pack Component Side 378 UNPROT 4321 PROT SMPLX o o o E amp M TN760D Option Switch Settings and Administration Installation Situation Circumstance Co Located Inter Building Co Located Inter Building Co Located Inter Building Co Located Inter Building To Sys75 G1 Sys75 G1 Sys85 G2 Sys85 G2 DIMENSI ON PBX DIMENSI ON PBX Other Other Preferred Signaling Format System Simplex Type 5 Simplex Type 5 Simplex Type 5 Simplex Type 5 E amp M Type 1 Compatible Protected Type 1 Compatible E amp M Type 1 Compatible Protected Type 1 Compatible Far End Simplex Type 5 Simplex Type 5 Simplex Type 5 Simplex Type 5 E amp M Type 1 Standard Protected Type 1 Standard E amp M Type 1 Standard Protected Type 1 Standard Plus Protection 379 Set E amp M SMPLX Option Switch SMPLX SMPLX SMPLX SMPLX E amp M E amp M E amp M E amp M 1758183 RBP 050896 Set Prot Administered Unprot Port Option Switch Either Type 5 Either Type 5 Either Type
84. The Avaya Media Gateway can be connected to all DTE terminals that have RS 232 or EIA 232 or DCP interfaces Terminals include 139 Connectable Voice and Data Terminals Connectable Administration Terminals Task List Connect Voice and Data Terminals Connect a Typical Telephone Connect Adjunct Power Connect an Analog Station or 2 Wire Digital Station Connectable Voice and Data Terminals These voice and data terminals can connect to an Avaya Media Gateway Voice and Data Terminals Terminal Model Type Multi button Electronic Telephone MET sets Voice 10 20 30 Button Analog Analog voice 500 2500 2554 2500 DMGC 2500YMGK S203A Speakerphone 46xx series Internet 4602 4602SW 4606 4612 4620 4620SW 4624 4630 Protocol IP 4630SW 71XXX series Analog voice 7101A 7102A 7103A 7104A 73XXX series Hybrid voice 7302H 7303H 7303S 7305S 7305H 74XXD series Digital voice 7401D 7403D 7404D 7405D 7406D 7407D 7410D 7434D 7444 81XX series Analog voice 8102 8110 91XX series 9101 9103 9110 64XX series Digital voice 6402 6402D 6408 D D 6416D 6424D XM24 84XX series 8403B 8405B D B D 8410B D 8411B D 8412 8434 8435 94XX series 9403 9410 9434 Basic Rate Interface BRI 75XX series BRI voice 7505 VOM T 7506 VOM T 7507 VOM T 85XX series 8503 8510 8520 140 Voice and Data Terminals Terminal Model Type Workstation series Business Communications Ter
85. This modifies the translations for the TN750B circuit pack to reference the TN750C circuit pack Verify proper playback of the announcements from the TN750C circuit pack by calling them Type release board 01c11 and press Enter for the TN750 B circuit pack where 01c11 is an example circuit pack location Return to Task List Add additional TN750C Circuit Packs Begin Return to Task List 1 Install the TN750C into a vacant slot in a carrier Any carrier is acceptable since power holdover is not a concern Administer a new data module on the TN750C circuit pack as described in Administrator s Guide for Avaya Communication Manager Type change announcements and press Enter to administer new announcements to that TN750C slot Fill in the designated board location field for the circuit pack s location Record the announcements as described in Administrators Guide for Avaya Communication Manager Wait until the announcements copy from voice RAM to the on board flash memory the yellow LED on the TN750C starts and then stops flashing This may take about 10 minutes Return to Task List Move a Single Announcement from one Announcement Circuit Pack to another Begin Return to Task List 1 2 Type change announcements and press Enter to change the circuit pack locations of a particular announcement You may also change the compression rate at this time Rerecord the announcement as described in Administrat
86. Type bye and press Enter to end the FTP session You can schedule the download to occur immediately or at a later date and time The procedures for self and C LAN distributed download methods differ at this step 1 Type change firmware download and press Enter 346 2 Fill in the fields as described in Firmware Download fields and descriptions on page 347 Firmware Download fields and descriptions Field Description Notes Source Board s Location Firmware Image File Name Target Board Code Suffix Firmware Vintage Type the UUCSS address of the source circuit pack Type the complete filename of the new firmware image file If the list directory board command showed that the file had an extension such as bin include the extension as well Type the circuit pack ID for example TN2501 Do not type the suffix such as AP DP or Examples For VAL TN2501AP type AP For C LAN TN799DP type DP For DS1 TN464GP type GP This is blank It shows a value in the Firmware Download form of a display firmware download or a status firmware download For a self download the same board is the source board and target board For a C LAN distributed download this is the source C LAN location Enter the TN code of the target circuit pack s For a self download this is the same as for the source circuit pack Continued on next page 3
87. Type the new server name in the Computer Name field 4 Type the new domain name in the Domain field and click OK gt OK gt Close 5 When prompted to reboot the computer select one of the following options No if you have not assigned IP addresses then go to Assign an IP Address Yes if you have assigned IP addresses Return to Task List Assign an IP Address Begin Return to Task List 1 Click on My Computer gt Control Panel gt Network 2 Click the Protocols tab 3 Select TCP IP Protocol from the list 4 Click the Properties option in the Network window 5 Onthe TCP IP Properties Window IP Address Adapter 1 verify that the Adapter drop down menu lists 2 DEC Ethernet adapters A CAUTION Do not change any settings on the adapter labeled 1 for any reason 6 On the TCP IP Properties Window IP Address Adapter 2 select the DEC Ethernet adapter labeled 2 7 Type a valid IP address for the IP Interface server in the IP Address field 8 Type the appropriate subnet mask in the Subnet Mask field TCP IP Properties Window IP Address Adapter 1 Microsoft TCP IP Properties ay EE WM HEU RUBER 1 Digital Semiconductor 21041 based Ethernet Controller 192 41 13 9 255 255 255 0 ar TCP IP Properties Window IP Address Adapter 2 266 Microsoft TCP IP Properties 2 Digital Semiconductor 21143 based 10 100 mpbs Ethernet m Assign Default Gateway Begin Retur
88. Using 1151A1 and 1151A2 Power Supplies Connect the 115141 or 1151A2 Power Supplies 1145B Power Supply The 1145B2 closet power arrangement provides an uninterruptible 48 VDC power source with battery and 1146B2 distribution unit for ISDN DCP terminal equipment adjuncts and other customer supplied equipment During AC power interruptions batteries automatically provide power to the load Although this power supply is available we recommend that you use the 1151B1 or 1151B2 power supplies Note Before you begin read this Important Warning for 1145B Power Supply Perform these tasks in order 1 Install the Wall Mounting Plates 2 Mount the 1146B Power Distribution Unit 3 Install the Battery Mounting Wiring 4 Install the Expanded Power Distribution Unit 5 Power Up and Test the Power Supply 6 Wire the 1146B Power Distribution Unit 183 7 Reset LEDs on Power Distribution Unit 1145B 1146B Mounting Arrangement shows how the standard power supply and wall mounting plates fit together Expanded Power Distribution Unit shows the expanded power supply components power distribution unit and T cable A manual switch on the distribution unit allows the user to redirect reserve power to outputs 1 through 32 so all outputs are provided battery reserve power or to outputs 1 through 8 to provide high power above 6 25 watts Note The switch must be set to the 1 32 position The 1145B 1146B is a 48V power supply with 275 watts t
89. a management terminal CDR or as a journal printer set the options as shown in 572 Printer Used with Management Terminal CDR and Journal Printer If the printer is used as the system printer set the options as shown in 572 Printer Used as System Printer 4 Use Line Feed or Form Feed to step through the options for the function 5 Press On Line This activates the menu for the function Use Line Feed and Form Feed to step through the options for the function 6 When a desired option is located press Print Quality Each time an option is set the setting is printed Repeat for each option to be set 7 When finished press Print Quality The printer changes to normal mode Control Panel for 572 Printer Power Alarm Print On Line Form On Quality Line Feed Feed 1781610 RBP 071096 Figure Notes 1 Power On Button 2 Alarm Button 3 Print Quality Button 4 On Line Button 5 Line Feed Button 6 Form Feed Button Table 1 572 Printer Used with Management Terminal CDR and Journal Printer Function Function Name Menu Menu Status 01 FORM LENGTH 09 11 02 LPI 01 6 03 CPI 01 10 04 LQ or NLQ 01 LQ 05 BUZZER 01 ON 06 FONT 02 FONTCART 07 RESOLUTION 01 144 11 BUFFER 02 N LINE 13 PW ON MODE 01 ON LINE 14 DIRECTION 01 B1 DIR 1 15 BUFF FULL 02 LF CR 16 P E 01 ACTIVE 372 Table 1 17 18 22 31 32 33 34 35 81 82 83 84 85 91 92 93 94 95 96 Table 2 AUTO CARRIAGE
90. access For use with an ethernet network connect the appropriate pins of the I O field to the hub For pinouts and diagrams refer to Connector and Cable Diagrams Pinout Charts In other configurations the TN799x circuit pack carries signaling over point to point protocol PPP for subsequent inclusion via the switching fabric in the same DS1 bitstream as the DSC voice transmissions A remote socket control link RSCL links the C LAN and the SPE to pass call control and other management information Because one link serves all the ports on the circuit pack RSCL maintenance is part of the C LAN circuit pack maintenance For further information about DCS refer to the Administration for Network Connectivity for Avaya Communication Manager Task List Add DCS Install Cables Add DCS Add Circuit Packs Add DCS Test the External Connection to the LAN Add DCS e Deliver License File Add DCS e Administer DCS Add DCS Save Translations Add DCS Return to Task List Install Cables Add DCS Begin Return to Task List Install cable from the cabinet to a hub or Internet Protocol IP Switch as required See Cable Connection for C LAN For a pinout of TN799x see TN799x Pinout From the rear of the cabinet 1 Connect the 259A connector to the backplane connector corresponding to the TN799x slot 225 2 Connect one end of the 5 cable to the 259A connector Connect the other end to the customer
91. block connectors in the green field 3 Connect 1 pair patch cords jumper wires from each 110 type terminal block row in the green field to the 110 type terminal block rows in the purple field for 1 pair Central Office CO trunks or in 3 Pair Modularity for Trunk Pairs for 3 Pair Tie Trunks for 3 pair tie trunks 3 Pair Modularity for Trunk Pairs for 1 Pair Trunks 9 12345 67 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 4 7 1013 16 19 22 9 1 4 7 1013 16 19 22 1 4 7 10 13 16 19 22 9 9 1758425b MMR 031496 Figure Notes 1 Green Field 2 1 Pair Jumpers 3 Pairs 4 Purple Field 3 Pair Modularity for Trunk Pairs for 3 Pair Tie Trunks TT 9 123 45 6 7 8 9 1011 12 13 14 15 16 17 18 19 20 21 22 23 24 123 45 6 7 8 9 101112 9 12345678 9 1011 12 9 1758537b MMR 031496 Figure Notes 1 Green Field 2 1 Pair Jumpers 3 Pairs 4 Purple Field Return to Task List Install Cables Between Cabinet and MDF Begin Return to Task List 1 A 6 7 Install D rings on the wall between the cable slack manager and the terminal connecting blocks mounted on the MDF Install a self adhesive port label on the back of each connector on the connector cable Position the labels so the cabinet connector retainers do not cover them At the rear of the c
92. blocks equipped with SCP 110 protectors can be used for sneak current protection Note Sneak current protectors with a rating of 350 mA at 600 volts must be Underwriter s Laboratory UL listed for domestic USA installation and Canadian Standards Association CSA certified for Canadian installation The 507B includes 52 sneak fuses and two cables The SCP 110 protectors are used with 110 type hardware and on the 507B Sneak Fuse Panel The SCP 110 Protectors can be ordered separately and installed on the 157B connecting block Fifty protectors are required per block Cable Installation Note To route the cables from the rear of the SCC1 stack or MCC1 to the MDF use the Install Cable Slack Managers procedure Also see Cable Slack Manager This section has information about Equipment Room Cabling Labels Cable Routing Guidelines Control Carrier Outputs Cable Installation Connect Control Carrier Outputs Cable Trunk Cables Among Network Interface Sneak Fuse Panel and Cabinet And procedures for Label Control Carrier Cable e Connect Control Carrier Outputs Cable Connect Trunk Pairs Using Concentrator Cables e Connect Trunk Pairs to Cabinet Using Jumper Wires To Establish 3 Pair Modularity Install Cables Between Cabinet and MDF 56 e Install Connector Cables Between Auxiliary Cabinet Equipment Room Cabling Labels The purple port label shown in Equipment Room Cabling Labels is installed on both ends of
93. circuit pack The circuitry and power source for the device are customer provided Note A maximum of 3 devices can connect to 1 analog line circuit pack port 1 Wire the ringing device to the information outlet as shown in 3 Pair and 4 Pair Modularity and Example Adjunct Power Connections 2 Administer per the Administrator s Guide for Avaya Communication Manager 3 Pair and 4 Pair Modularity 9 9 1 26 1 vira pit 1 2 2 21 2 27 3 3 3 3 gt 2 4 4 E 4 28 5 E 1 3 6 6 6 7 2 7 PDH 011397 Figure Notes 1 Port Circuit Pack 2 System Cabinet Connector Pins 3 Pair Modularity 3 Main Distribution Frame MDF Pins 3 Pair Modularity 4 Input to Information Outlet 4 Pair Modularity 5 Adjunct Power 6 Output From Information Outlet 4 Pair Modularity 7 Voice or Data Terminal Pins Example Adjunct Power Connections 178 e Bl e p cydfadjn KLC 020599 Figure Notes 1 Typical Display Telephone 2 Individual Power Supply Such as 1151A1 or 1151A2 3 Information Outlet Modular Jack 4 4 Pair D Inside Wire DIW Cable 5 Satellite Site or Adapter Location 6 25 Pair D Inside Wire DIW Cable 7 Station Side of Main Distribution Frame MDF 8 100P6A Patch Cord or Jumpers 9 System Sid
94. circuit pack is in a port carrier and the TN 573B SNI circuit pack is in the Switch Node Carrier connect the two circuit packs with a 70 in 178 cm Y Cable A CAUTION The Y cable used with the TN1654 circuit pack is different than the Y cable used with the TN574 circuit pack These cables are NOT interchangeable 2 Connect an H600 348 Quad cable to the other side of the Y cable Connecting Through a Channel Service Unit Begin Return to Task List 311 DS1 Converter Connections for 1 Service Part 2 shows a typical connection for a T1 line and DS1 Converter Connections for 120 ohm E1 Service Part 2 shows a typical connection for an E1 line 1 Connect the H600 348 Quad Cable to the DTE jacks on each of the 4 CSUs 2 You may need an adapter cable to connect the H600 348 cable to the CSU see Adapter Descriptions 3 Connect one end of the H600 383 cable to the network jack on the CSU and the other end to the smart jack Connection to the remote located system is the same as that shown in DS1 Converter Circuit Pack Switches and CAMA Numbering Format form Y Cable Lengths shows theY cable lengths The distinction between facility types is important when using TN1654 circuit packs The facility used to carry control channel messages between the pair of DS1 converter circuit packs and all packet traffic is known as the primary facility The facility used to backup and takeover for the primary facility in the event of
95. connector of the external cable assembly 4 Plug the monitor into an AC power receptacle and turn it on Return to Task List Connect the Ethernet Begin Return to Task List Connect the network cable to the ETHERNET connector on the TN802B external cable assembly 260 You need a CAT5 or better cable for 100 Mbyte operation Install the Circuit Pack Begin Return to Task List Note The TN802B IP Interface is hot swappable so you do not need to power down the carrier to install it If you need to remove the TN802B IP Interface from the carrier at a later time shut down Windows NT first by pressing the recessed reset button on the faceplate see TN802B IP Interface faceplate of the TN802B IP Interface until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min it is safe to remove the circuit pack 1 Insert the TN802B IP Interface into the rightmost of the three slots you reserved for it see J58890MA 1 L30 IP Interface Assembly Note To properly seat the circuit pack push firmly on the front of the faceplate until the latch reaches the bottom rail of the carrier Then close the latch until it is fully engaged When you plug in the TN802B IP Interface the circuit pack starts to boot and the LCD reads PC Boot then after about 3 to 4 minutes it changes to IP TRK the default mode TN802B IP Interface faceplate 59 9
96. connector on the SYSTEM end of the Y cable Route a B25A cable from the CLOCK end of the Y cable to the cross connect module in the yellow field Repeat steps 2 and 3 for the secondary CSU The maximum allowable cabling distance between the Stratum 3 clock and the CSU is shown in Maximum Cabling Distance For standard reliability systems refer to Cross Connects for Standard Reliability to cross connect the TN780 and CLOCK end connections to the Stratum 3 Clock connections on the cross connect module For high or critical reliability systems refer to Cross Connects for High or Critical Reliability to cross connect the TN780 and CLOCK end connections to the Stratum 3 Clock connections on the cross connect module The common cross connection from the TN780 in A and B carriers to the Stratum 3 Clock should be done by bridging the jumper wires Dress the cables down sides of the cabinet and run through the Cable Slack Manager if provided Administer per the Administrator s Guide for Avaya Communication Manager Maximum Cabling Distance Channel Service Maximum Cabling Unit CSU Distance 551A 85 Feet 26 m 551V 85 Feet 26 m 551V EFS R 655 Feet 199 6 m EFS 1 655 Feet 199 6 m Cross Connects for Standard Reliability From Stratum 3 Clock To Y Cable Clock End Primary Lead Lead Connecting Lead Lead Connecting Designation Color Block Designation Color Block Terminal Terminal RREF1 W BL
97. examples 308 Examples of typical settings Switch Settings Description T1 ESF 3 Span A through D Framing set for ESF re T1 D4 Span A through D Framing set for D4 swdftid4 092799 E1 120 ohms ESF Span through D Line Impedance set for ESF swdfe1es 092799 Return to Task List Installing TN1654s in a Port Carrier Begin Return to Task List 1 a A Install the TN1654 circuit pack in any slot in a Port Carrier close to a TN570C Expansion Interface circuit pack On the backplane connect a 14 inch 35 56 cm Y cable from the TN1654 circuit pack to the TN570C circuit pack See DS1 Converter Connections Part 1 The Y cable used with the TN1654 is different than the Y cable used with the TN574 These cables are NOT interchangeable Connect an H600 348 Quad cable to the other side of the double headed Y cable Skip to Connecting Through a Channel Service Unit DS1 Converter Connections Part 1 309 cydf010 091399 20 1 Figure Notes 1 Port cabinet 2 Backplane connector for TN570C EI 3 Backplane connector for TN1654 DS1 Converter 4 50 pair female connector to El connector 5 14 in 35 6 cm Y cable 6 50 pin male 50 pin female double headed connector 7 H600 348 Quad Cable with 50 pin male connector which connects the Y cable to the 4 CSUs Return to Task List Installin
98. fiber optic hardware requirements Single mode fiber optic cable consists of two separate 8 to 10 micrometer core cables Note 5 and 10dB attenuators are available Contact your Avaya representative for more information Return to Task List 389 Labels for Fiber Optic Cables Cable Labels Cross Connect Labels Return to Task List There are two types of labels used with fiber optic cables e Cable labels e Cross connect labels Cable labels are used on the cables and cross connect labels are used on the cross connect equipment Cable labels with adhesive backing are installed on each end of a fiber optic cable Each label displays the following information The numbers of the cabinets carriers and slots connected by the cable Information on the cable itself such as cable comcode number and how it is used The label used with cross connect fiber optic cables shows the cabinet carrier and slot numbers of the source of the cable It also indicates that the cable goes to the Main Distribution Frame MDF Return to Task List Cleaning Fiber Optic Cables Begin The use of isopropyl alcohol is recommended to properly clean fiber optic cables Contact your Avaya representative for more information 1 Moisten a lint free cloth with isopropyl alcohol 2 Wipe the ceramic ferrule with the cloth Be sure to wipe the entire length of the ferrule and the ferrule tip 3 Dry the ferrule with air 4
99. field is 911 4 In the No License Incoming Call Number field optional type a valid extension Note All calls are not rerouted to this number only calls to this number get through This number cannot be a hunt group or ACD number 5 Press Enter to save the changes 109 Return to Task List Change Site Data MCC1 only Begin Return to Task List This screen initializes the building floor and color data to make them available later in help messages that refer to site 1 Type change site data and press Enter 2 Type in the optional names for the buildings or offices served by the system 3 Access the remaining site data pages and fill them in appropriately Change Cabinet 1 MCC1 only Begin Return to Task List If you are not familiar with the fields on the Cabinet Administration form refer to Cabinet Field Descriptions and Carrier Descriptions 1 Type change cabinet 1 and press Enter A screen similar to Cabinet Administration form appears 2 Fill in the blanks as required by the location and nature of the cabinet If the system is critical reliability verify the B field is set to the processor option the D field is set to the dup sw node option and the E field is set to the switch node option Cabinet Field Descriptions Field Name Field Description Cabinet Display only field This field shows the cabinet number as entered in the command line Cabinet Layout Enter the type of physical carrier layo
100. high reliability CSS system 46 installing 45 labels 390 391 402 multimode 389 single mode 389 standard reliability CSS system 45 fiber optic cable pass thru kit MCCI 391 fiber optic cable connecting 385 fiber optic cable handling 385 fiber optic duplication interface cabling MCC 43 fiber optic pass thru kit 395 firmware downloads uploading image files from Web 345 Firmware download 341 firmware download aborting a download 352 backing out of 353 disabling file system 352 preparing to download 343 removing files 352 reverting to an older vintage 353 scheduling 346 350 testing a C LAN distributed download 352 testing a self download 352 troubleshooting downloads 352 429 Index uploading image files from Web 345 uploading image files using FTP 345 firmware download procedure C LAN distributed 342 self download 342 firmware downloads circuit pack roles 341 high level procedure 341 flash card installing 103 floor grounds 383 floor plans 71 Forum Personal Communications Manager 200 France country code 114 FTP setting up circuit pack to receive files 345 FX trunks 296 G gateway assigning 267 Germany country code 114 Greece country code 113 ground coupled bonding conductor 25 coupled bonding connector 60 ground ring 383 ground wiring DC 32 ground cabinets 34 grounds approved 383 connecting AC 23 H handling fiber optic cab
101. long and permits alphanumeric characters to provide a unique qualifier for a given modem such as INTEL RTS CTS Informs the modem that communication with the data source UART is Enabled driven with RTS CTS flow control The field name has a default of Q3 ina field 6 characters long This field is not case sensitive Default is upper case Asynchronous Configures modem as an asynchronous communications device The field Data Mode name has a default value of amp M0 amp Q0 in a field 8 characters long This field is not case sensitive Default is upper case DTE Adjusts the speed of the data source DTE UART to the outgoing Auto Data modem to modem data rate At maximum this speed is 9600 baud It is Speed not desirable to have the serial data fill the modem buffer faster than the outgoing data rate since data compression is disabled The field name has a blank default value in a field of 6 characters Avaya products use the command 90 1 to enable this functionality while the Intel product uses the command M1 to enable similar functionality This field is not case sensitive Default is upper case Disable Data Turns off the default data compression algorithms in use by most modems Compression Enable Error Control The field has a blank field of 6 characters as default The AT commands that control this are supported by similar commands however these commands do not operate in the same manner The Intel modems requi
102. may vary depending upon the system configuration being administered The number of slot fields displayed may vary depending on the system being configured Change Circuit Packs Screen change circuit packs Page l of CIRCUIT PACKS Cabinet 1 Carrier A Carrier Type processor Slot Code Sf Mode Name 01 TN758 POOLED MODEM 02 TN726 B DATA LINE 03 TNT7T63 AUXILIARY TRUNK 04 TN750 ANNOUNCEMENT 05 TN2181 DIGITAL LINE 06 TN464 F DS1 INTERFACE 07 TN2138 CO TRUNK 08 TN754 B DIGITAL LINE 09 TN799 B CONTROL LAN 10 TN767 D DS1 INTERFACE Slot Code Sf Mode Name Slot Code Sf Mode Name 11 TN464 F DS1 INTERFACE 01 TN758 POOLED MODEM 12 MEDPRO RESERVED IP 02 TN726 B DATA LINE 13 TN802 B MAPD BOARD 03 TN763 D AUXILIARY TRUNK 14 TN2149 ANALOG LINE 04 TN750 C ANNOUNCEMENT 15 TN754 B DIGITAL LINE 05 TN2181 DIGITAL LINE 16 TN754 B DIGITAL LINE MA indicates circuit pack conflict 94 DEFINITY AUDIX System Power Procedures Manually Power Down AUDIX System A yellow caution sticker on the system s power unit notifies technicians to shut down the DEFINITY AUDIX System prior to powering down the system 1 Using a pointed object such as a paper clip or pen do not use a pencil press the Boot Shutdown button The button is located at the top right portion of the front panel 2 Hold the Boot Shutdown button in until the LCD display flashes the message MSHUT 3 Release the Boot Shutdown bu
103. network equipment 4 Single point ground connection 5 gt 0 75 mm 18 AWG ground wire to ground terminal at MDF 307 DS1 Converter Connections for E1 75 ohm Service Part 2 eo A1200 750 Ol 4 I R In B1200 750 a 10 106060801 wel ol 2 0 1200 SS 92 01 19 3 5 4 I o 6009902929 hidfcsu1 LJK 110601 Figure Notes 1 H600 348 quad cable 2 15 pin male D connectors 3 127A BALUN coaxial adapter 4 BNC connectors transmit receive corresponding to each facility 5 E1 network connection 6 Network interface Set Circuit Pack Switches TN1654 DS1 Converter Begin Return to Task List 1 Set the configuration switches on the TN1654 as required per site 2 Set Switch 6 down disabled Switch 6 may not be present or active on all TN1654 DS1 Converter circuit packs 3 Set Switch 1 up for T1 facilities All subsequent facility switch settings Switches 2 5 reflect T1 framing on each of the 4 facilities See Examples of typical settings 4 Set Switch 1 down for E1 facilities All subsequent facility switch settings Switches 2 5 reflect E1 impedance on each of the 4 facilities See Examples of typical settings for
104. new fields appear 13 In the Data Lock field choose YES for products with ASG enabled NOfor all others 14 In the Dialing Type field choose the dialing type that the product will use to report alarms DON T CHANGE to leave the product s dialing type unchanged TONE for DTMF dialing PULSE for rotary or pulse dialing 15 In the Alarm Origination field choose DON T CHANGE to leave the product s current alarm origination status unchanged the common choice for upgrades YES to enable alarm origination NOfor no alarm origination 16 Inthe Alarm Destination field choose DON T CHANGE to leave the product s currently administered alarm origination number unchanged the common choice for upgrades SET NUMBER TO and type the complete alarm destination telephone number including any dialing prefix for example 9 or 9 The default value in this field is the TSO Denver number 18005353573 17 Click on the Continue Registration button at the bottom of the page ART begins automatically registering the product and displays progress messages to indicate the current status A CAUTION DO NOT exit your browser or click on the Refresh Back Stop or Home buttons while ART displays these progress messages If you have to abort your registration click on the Abort Session button that appears with one of the progress messages If the preceding steps have been completed successfully ART displays the DEF
105. ohm coaxial or 120 ohm CEPT twisted pair Fiber Link Administration form for B PNC DS1 Converter DS1CONV Attributes Page 3 of 3 a fiber link next FIBER LINK ADMINISTRATION B PNC DS1 CONVERTER DS1CONV ATTRIBUTES DS1CONV Board Location 01C01 DS1CONV Board Type TN1654 DS1 CONVERTER FACILITIES DS1CONV Board Location 02C01 DS1CONV Board Type TN1654 A B Facility Installed yes yes yes no Bit Rate 2 048 Facility Startup Idle Code 11101000 Line Coding hdb3 hdb3 hdb3 hdb3 CRC yes Line Termination Facility A Circuit ID OAABBO1 Facility B Circuit ID OCCDDO02 Facility C Circuit ID OEEFFO03 Ss Return to Task List 414 Color W BL BL W W O O W W G G W W BR BR W W S S W R BL BL R R O O R R G G R R BR BR R R S These pinout charts provide wire color and connector pin numbers for Connector and Cable Diagrams Pinout Charts Circuit Pack and Auxiliary Equipment Leads Pinout Charts includes 2 and 4 wire analog and digital lines 8 16 and 24 ports hybrid line MET line AUX and CO trunk Circuit Pack and Auxiliary Equipment Leads Pinout Charts includes 3 wire CO trunk DID DIOD trunk tie and DS1 tie trunk 2 and 4 wire ISDN BRI lines packet data line and 4 port DIOD Lead and Color Designations TN2185B ISDN BRI 4 wire S Interface TN2198 ISDN BRI 2 wire U Interface TN793B 24 Port Analog Line circuit pack DS1 Interface Cable H600 307 Circuit Pack
106. or TILTWATCH indicators on the container If the container has been shaken or tilted beyond specifications the indicators are red indicating potential damage Report any damage according to local shipping instructions AX DANGER Take care to avoid injury while cutting and removing the 2 metal bands 2 Unpack the cabinet and remove all packing material 3 Move the cabinets into their proper positions 4 Do not adjust the leveling feet at this time Return to Task List Unpack and Inspect Auxiliary Cabinet Begin Return to Task List The Auxiliary cabinet is normally positioned adjacent to the PPN cabinet or the EPN cabinet if provided 1 Check the status of the SHOCKWATCH and or TILTWATCH indicators on the container If the container has been shaken or tilted beyond specifications the indicators are red indicating potential damage Report any damage according to local shipping instructions AX DANGER Take care to avoid injury while cutting and removing the 2 metal bands 2 Unpack the cabinet and remove all packing material 3 Move the cabinet into its proper position 4 Remove the lower rear panel from the Auxiliary cabinet 18 Note You reinstall the lower rear panel when the installation is completed Return to Task List Check Circuit Packs Begin Return to Task List 1 Ensure all circuit packs are fully inserted into the proper slots according to the Customer Service Document CSD Report any discre
107. parts ACTION OBJECT and QUALIFIER e ACTION is the first part of the command When command appears on the screen The ACTION specifies the operation desired Examples include add duplicate change remove display list and save e OBJECT is the second part of the command and specifies the particular object to be administered Typical entries are hunt group coverage path and station e QUALIFIER is the last part of the command It is one or more words or digits used to further identify or complete the OBJECT For example hunt group 15 or station 3600 where 15 and 3600 are qualifiers An example of the command line required to add a station with extension number 1234 is add station 1234 In this example add is the ACTION station is the OBJECT and 1234 is the QUALIFIER In the command line spaces are required between the ACTION OBJECT and QUALIFIER To save time enter enough letters for each part of the command to make it unique For example if you want to enter the command change system parameters country options typing cha sys coun is sufficient Note The craft or dadmin logins may not be allowed to perform some of the steps needed to initialize the system If access is denied to some of these procedures contact Avaya for assistance Use the Help key for a list of options and the Cancel key to back out of any command Refer to the Administrator s Guide for Avaya Communication Manager for detailed procedures Admin
108. press Enter The variable nnn nnn nnn nnn is the IP address of the TN799x C LAN circuit pack and UUCSS is the cabinet carrier and slot of the TN799x C LAN circuit pack 2 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the customer s gateway and UUCSS is the cabinet carrier and slot of the TN799x C LAN circuit pack 3 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of another computer beyond the gateway and UUCSS is the cabinet carrier and slot of the TN799x C LAN circuit pack The TN799x C LAN circuit pack is now installed in the DEFINITY carrier and connected to the IP network Return to Task List Deliver License File Add DCS Begin Return to Task List A CAUTION This procedure must be done immediately after you upgrade the software If the license file is not installed within 10 days the switch enters a No License mode and shuts down all call processing 1 Retrieve the RFA License File with both serial numbers from the RFA Application 2 Type set time and press Enter Ensure that the system date and time are set correctly 3 Use one of these installation methods Direct connection between the switch and RFA 227 New simplex and upgraded G3r only New or upgraded G3si only N A 1 N A No connection between the switch and RF
109. r764787 PDH 071596 Example 3 Pair Labeling to Information Outlet 9 LLL LLL LLL LLL LLL LLL LLL L ZLL LLL LL LL ZZZ LLULL LLL LLL LLL LLL LLL LLL LLL LLL LLL LLL LLL 9 9 gt 59 amp erdf5pr CJL 103096 78 Figure Notes 1 Equipment Room 2 Satellite Location 3 Work Location 4 White Row on 110 Terminal Block 5 Purple Row on 110 Terminal Block 6 Blue Row on 110 Terminal Block 7 Central Location for Terminals 1 through 6 8 D Inside Wire Cut Down to Connecting Block 9 258A Adapter 10 Information Outlet 11 Voice Terminal 12 To Port Connector on Cabinet Cabinet 1 Carrier A Slot 03 Example 4 Pair Labeling to Information Outlet LLLLZLLLN LLL LL LLL LLL LLALL L LLL LLL LLL LLL LLL LLL LL crdf4pr CJL 102996 Figure Notes 1 Equipment Room 2 To Central Location for Terminals 1 through 6 3 Blue Row on 110 Terminal Block 4 Purple Row on 110 Terminal Block 5 To Port Connector on Cabinet Cabinet 1 Carrier A Slot 03 6 258A Adapter 74 7 D Inside Wire Cut Down to Connecting Block 8 Information Outlet
110. reliability type status system 1 and press Enter to verify that the system is in the active standby mode 2 Type save translation and press Enter This instructs the system to take all translation information in memory and write it to the translation cards 218 Add Circuit Packs CallVisor ASAI Begin Return to Task List 1 Determine port assignment of circuit packs to be added 2 Install the appropriate circuit packs in assigned cabinet slot as required Note A vacant port is required on a TN556 B ISDN BRI circuit pack Return to Task List Install Cables CallVisor ASAI Begin Return to Task List Install cables from cabinet to the MDF as required Enter Added Translations CallVisor ASAI Begin Return to Task List Administer the required translation data using the forms listed under Adjunct Switch Applications Interface ASAI in the Administrator s Guide for Avaya Communication Manager Resolve Alarms CallVisor ASAI Begin Return to Task List Examine the alarm log Resolve any alarms that may exist using the Maintenance for Avaya MultiVantage DEFINITY Server documentation for your system Save Translations CallVisor ASAI Begin Return to Task List 1 Ifthe system is high or critical reliability status system 1 and press Enter to verify that the system is in the active standby mode 2 Type save translation and press Enter This instructs the system to take all tran
111. separate screws on the receptacle cover 4 Route the ground wire to the DC power plant and connect to DISCH GRD inside the cabinet 318 Connect Stratum 3 Clock DC Power Begin Return to Task List 1 Set the clock cabinet circuit breaker at the DC power plant OFF 2 Atthe clock cabinet connect a 6 AWG 40 16 mm ground wire to the 48V terminal on the terminal strip 3 Atthe clock cabinet connect a 6 AWG 40 16 mm wire to the 48VRTN terminal on the terminal strip 4 Route the wires out of the cabinet and to the DC power plant 5 Atthe DC power plant connect the 48V wire to the DC OUTPUT circuit breaker 6 Atthe DC power plant connect the 48VRTN wire to the DISCH GRD bar Return to Task List Set the Clock Options Begin Return to Task List There are four sets of option switches on the clock 1 Set the options on the Clock Input Cl circuit pack according to Cl Option Switch Settings 2 Set the options on the Stratum Clock ST3 circuit pack according to ST3 Clock Circuit Pack Option Switch Settings 3 Set the options on the Composite Clock Timing Output TOCA circuit pack according to Composite Clock Timing Output TOCA Circuit Pack 4 Setthe Stratum 2 Stratum 3 switch to the STRATUM 3 position Cl Option Switch Settings Switch Function Position 1 T1 Select OFF enable default ON disable 2 CC Select OFF enable ON disable default 3 Framing Select OFF ESF ON D4 default 4
112. strip Provides switched and unswitched 120 VAC receptacles DC connector block Required when Auxiliary cabinet is powered by an external DC source AC to DC power supply Converts AC power provided by the AC power strip switched outlet to the required DC voltage Install equipment inside the cabinet as specified in the CSD The following optional equipment can be installed e Audichron H9040 Wake Up Announcement System 909A B Universal Coupler 7400 Series Data Modules e Z77A Multiple Data Mounting Fan Assembly Requires 120 volt AC power e COMSPHERE 3000 series modems e External Channel Service Unit CSU 1 is required for each T1 carrier link PagePac Paging System 3 models are available All PagePac models require 120 VAC power 20 Model 15A Announcement System see the table for a list of equipment The BLD1 circuit pack provides 8 channels with up to 20 seconds of recording time on each channel The BLD2 circuit pack provides 8 channels with up to 40 seconds of recording time on each channel Each chassis can be populated with any combination of 2 BLD circuit packs The Model 15A Announcement System is FCC registered and does not require a voice coupler Model 15A Announcement Equipment Description 1 chassis and 1 BLD1 circuit pack 1 BLD1 circuit pack 1 chassis and 1 BLD2 circuit pack 1 BLD2 circuit pack 1 remote record module Return to Task List Install
113. the 25 pair cables connecting to the trunk auxiliary field and or distribution field The top blue yellow building and floor labels are for cables connecting from the equipment room to a site satellite location on another floor or in another building The yellow label is for auxiliary circuits connecting to the trunk auxiliary field The bottom blue yellow label is for 25 pair cables connecting to site satellite closets Equipment Room Labels details the label name and range of each label Self Stick Label on 25 Pair Cable Connector shows the proper way to install a label on a 25 pair cable connector Install the label near the rear of the connector so it is not obscured by the cabinet connector retainers It can also be installed on the skin of the cable near the connector Cable Routing Guidelines Cable Routing to Top Terminal Blocks and Cable Routing to Bottom Terminal Blocks show typical cable routing from the cabinet to the top and bottom of the MDF respectively Use these guidelines when routing cables from the cabinet to the MDF Following these guidelines will maximize use of the cable slack managers and make future cabling additions and changes easier e Connect each port cable at the cabinet and then route it along the front trough of the cable slack manager to the connecting terminal block where the cable is terminated Leave enough slack at the cabinet end of the cable to allow for proper dressing of the cables e R
114. the Customer Name and Customer Address fields If the information is not what you expected ensure that you entered the customer s FL Sold To number correctly Step 4 above If you entered an incorrect number a Click on the Abort Upgrade Registration Session button at the bottom of the Screen A CAUTION DO NOT exit your browser to abort the session This can result in an incomplete upgrade registration b Return to the ART User Menu page to begin a new session If the FL Sold To number matches multiple customers in the database ART displays the name and address of each customer with a button to select for this registration session 10 In the Customer Type field select GOODYEAR MOTEL 6 STATE FARM IN CINCINNATI BELL SERVICE AREA OTHER 11 Click on the Continue Upgrade Registration button The DEFINITY Product List page appears 12 Look in the product table first column heading is to find the row for the product that you want to register Click on the number in the far left column of the correct row Note It might be helpful to identify the product by looking at the Product Nickname Product Alarm ID INADS Number Serial Number or IP Address columns in the table 122 If the product is not shown in the table or if you are not sure whether a listed product is the one you want to register contact the DBA group for assistance 1 800 248 1234 selecting prompt 2 prompt 6 then prompt 2 Four
115. the License Installation Tool LIT application at your laptop PC 3 Use the LIT instructions to add a switch connection profile to the tool 4 Use the LIT instructions to install the License File on the switch 5 f the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints A CAUTION Administer DCS Add DCS Begin Return to Task List 1 Administer the required translation data using the screens listed under Distributed Communications System DCS in the Administrator s Guide for Avaya Communication Manager Save Translations Add DCS Begin Return to Task List 1 If the system is high or critical reliability type status spe and press Enter to verify that the standby SPE is refreshed and that the standby disk is in service 2 Type save translation spe a or both disk and press Enter This command instructs the system to take all translation information in memory and write it to the disk s 229 Administer TN464GP TN2464BP with Echo Cancellation Return to Task List Return to Task List This section provides information about the TN464GP and TN2464BP circuit packs with echo cancellation and the procedure to Administer TN464GP TN2464BP The TN464GP and TN2464BP circuit packs with echo cancellation are intended for DEFINITY customers who are likely to encounter echo over circuits connected to the Direct
116. the same Each circuit pack must be scheduled for download individually The high level steps used to perform a self or C LAN distributed firmware download are 1 Prepare for download on page 343 Upload image file from the Web to staging area on page 345 2 3 FTP the image file to source on page 345 4 Schedule a download to target s on page 346 5 Monitor download progress on page 350 342 Prepare for download 6 Disable file system on page 352 Note If you have any trouble with this procedure refer to Troubleshooting firmware downloads on page 352 The following subsections contain procedures to prepare for the firmware downloads to target circuit packs e Verify hardware software requirements on page 343 Get circuit pack information on page 344 e Setup source circuit pack s file system on page 345 Verify hardware software requirements Make sure you know which download procedure to use and that you have all the hardware and software that is necessary to proceed Given the type of target circuit pack to be upgraded choose an appropriate source circuit pack from the following table Download Method by Circuit Pack on page 343 The last column indicates which download method must be used with the target and chosen source Download Method by Circuit Pack Target Circuit Pack s Source Circuit Pack Download Method TN464
117. this LED HOLDOVE Ignore this LED R 361 Stratum 3 Clock LED Indicators LED Label Procedure FREE RUN Ignore this LED Card ST3 TOCA TOCA FAIL Replace the circuit pack PORT ALM Replace the circuit pack if necessary Return to Task List Verify Timing to the System Begin Return to Task List 1 To administer the Stratum 3 clock type change synchronization and press Enter 2 Type 3 in the stratum field 3 Type the port network number where the TN780 Tone Clock circuit packs reside in the port network field Note Wait 1 minute for the software to reconfigure the system synchronization 4 Verify the results of test 649 If test 649 fails with a code of 2101 then check the wiring for EXTSYNO and EXTSYN1 Refer to Maintenance for Avaya MultiVantage DEFINITY Server If test 649 is successful then the system is getting correct timing from the Stratum 3 clock Return to Task List Perform Complete System Test Begin Return to Task List Run the complete system test with the Allports option in the SPE Interchange and Long Test modes The hardware group tests are described in the Maintenance for Avaya MultiVantage DEFINITY Server documentation for your system Note This test takes several hours It may be best to run the test in the background or at night or both Resolve Alarms Begin Return to Task List After the test has completed inspect the alarms log Type display alarms and resolv
118. this field on a per circuit pack basis This is the idle code used when a TN1654 first establishes a link on a T1 E1 facility The initial idle code used by the TN1654 is overwritten by the center stage switch to an all ones pattern once framing is established on that T1 E1 facility Framing Mode For TN1654 with 1 544 Mbps Bit Rate this is a display only field Fiber Link Administration form for T1 TN1654 Circuit Pack DS1 Converter Complex Administration page 2 of 3 um fiber link next Page 2 of 3 N FIBER LINK ADMINISTRATION A PNC DS1 CONVERTER DS1CONV ATTRIBUTES DS1CONV Board Location 01B01 DS1CONV Board Location 02B01 DS1CONV Board Type TN1654 DS1CONV Board Type TN1654 DS1 CONVERTER FACILITIES A B Facility Installed yes yes no no Bit Rate 1 544 Facility Startup Idle Code 11101000 Line Coding ami zcs ami zcs ami zcs ami zcs Framing Mode DS1CONV 1 Line Compensation 1 1 1 1 DS1CONV 2 Line Compensation 1 1 1 1 Facility A Circuit ID 09876543 Facility B Circuit ID 234567889 m 27 Return to Task List Dupicated DS1 Converter Complex Administration for T1 TN1654 Circuit Packs Return to Task List 411 Fiber Link Administration form for E1 TN1654 Circuit Pack 051 Converter Complex Administration page 2 of 3 allows you to admininster the DS1 converter The following unique fields display when administering a TN1654 DS1 Converter e Bit Rate A display only field fo
119. to n A CAUTION If you do not disable Alarm Origination the system may generate alarms resulting in unnecessary trouble tickets 3 For some releases of software disable Cleared Alarm Notification and Restart Notification before submitting the form Return to Task List Save Translations Packet Bus Support Begin Return to Task List If standard reliability 1 Type status system 1 and press Enter to verify that the system is in the active standby mode If high or critical reliability 1 Type status system 1 and press Enter to verify that the system is in the active standby mode 220 2 Type save translation and press Enter This instructs the system to take all translation information in memory and write it to the translation card 3 If the system contains a TN750 B Announcement circuit pack type display announcements and press Enter If administered recorded announcements are listed type list configuration software version long and press Enter To save the announcements type save announcements and press Enter Return to Task List Power Down Cabinet Packet Bus Support Begin Return to Task List 1 At the PPN set the main circuit breaker to OFF 2 Atan EPN set the main circuit breaker to OFF Install Circuit Packs Packet Bus Support Begin Return to Task List Install the appropriate circuit packs See Circuit Pack Locations for Packet Bus in PPN Circuit Pack Locations for Packet Bus in PPN
120. type of AC power being provided contact a qualified service person Do not allow anything to rest on the power cord Do not locate this product where the cord will be abused by persons walking on it Do not overload wall outlets and extension cords as this can result in the risk of line or electric shock Disconnect the cords on this product and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is damaged or frayed If liquid has been spilled into the product If the product has been exposed to rain or water If the product was dropped or the housing has been damaged Ifthe product exhibits a distinct change in performance Ifthe product does not operate normally by following the operating instructions 196 Return to Task List Connect the 1151A1 or 1151A2 Power Supplies Begin Return to Task List The 1151A1 is a standard no battery backup power supply unit The 1151A2 is a battery backup version of the 1151A1 Either power supply can support one telephone with or without an adjunct The maximum loop range is 250 feet 76 meters Two modular jacks are used Power is provided on the PHONE jack pins 7 and 8 and respectively The PHONE and LINE jacks are 8 pin female non keyed 657 type jacks that can accept D4 D6 and D8 modular plug cables See an 1151A1 2 Power Supply Front 1151A1 2 Power Supply Front 36 pwr
121. unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints Type set time and press Enter Ensure that the system date and time are set correctly Use one of these installation methods Direct connection between the switch and RFA No connection between the switch and RFA Retrieve the RFA License File with both serial numbers from the RFA Application If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints Type set time and press Enter Ensure that the system date and time are set correctly For duplicated systems only type status system all and press Enter Ensure that the standby SPE is notin the maintenance state If it is wait for the maintenance state to finish Use one of these installation methods Direct connection between the switch and REA No connection between the switch and RFA Direct connection between the switch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File 108 Note This procedure sends the License File to the switch and installs it 2 If the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints No connection between the sw
122. up through the bottom of the cabinet For example if the distance from the floor anchor to the bottom of the cabinet is 10 in 25 cm cut the threaded rod 11 in 27 9 cm long When all 4 threaded rods are cut replace the raised floor panels removed in Step 5 Position the cabinet over the holes and adjust the leveling legs until the cabinet is level Note If the system is supplied with cable ductwork the cabinets must be level from front to rear and from side to side They must be square with respect to each other to within 1 8 in 0 3 cm 11 12 13 Insert the threaded rods through the cabinet bottom and thread into the concrete floor anchors Place a 3 8 in flat washer onto each rod Thread a 3 8 16 hex nut onto each rod and tighten securely Repeat this procedure for each cabinet to be installed including the Auxiliary Cabinet and the Stratum 3 Clock Cabinet if required Earthquake Mounting Raised Computer Floor 22 3 8 inch flat washer Nut welded to frame 18 4 inches 10 16 cm threaded rod raised variable floor height 3 8 16 Concrete floor anchor concrete subfloor cab base CJL 052096 Return to Task List Connect AC Power and Ground Return to Task List A CAUTION The equipment room AC power and ground wiring must be performed by a qualified electrician Refer to the System Description for site requirement information
123. which is your IP address If everything is configured correctly the system responds with the following message Reply from nnn nnn nnn nnn bytes 32 time lt ms TTL f no response verify the IP address information and check the connectivity including the cabling 3 At the command prompt type ping nnn nnn nnn nnn which is the IP address of your gateway If everything is configured correctly the system responds with the following message Reply from nnn nnn nnn nnn bytes 32 time lt ms TTL If no response verify the IP address information and check the connectivity including the cabling Ifall else fails click on Start gt Settings gt Control Panel gt Network Select the Adapters tab and highlight the 2 DEC adapter Click Properties gt Change From the Duplex Mode drop down menu select a setting that matches the switch hub that the TN802B connects to For example 10BaseT Full Duplex or 10BaseT No Link Test 4 At the command prompt type ping nnn nnn nnn nnn which is the IP address of another external computer beyond the gateway f you have connectivity the system responds with the following message Reply from nnn nnn nnn nnn bytesz32 time lt ms TTL f no response verify the IP address information and check the connectivity including the cabling Consult your IP network administrator 5 Type exit and press Enter Return to Task List Test the IP Interface On
124. 0 6 List of Fiber Pass Thru Kit Equipment Description Pass thru Tool Beige SC SC Fiber Optic Adapter multimode Beige ST SC Fiber Optic Adapter multimode Ten foot 3 m Fiber Optic Cable multimode Beige SC SC Fiber Optic Adapter single mode Beige ST SC Fiber Optic Adapter single mode 10 ft 3 m Fiber Optic Cable single mode Connector Adapter Bracket Fiber Optic Cable Disconnect Label Cable Ties Cable Tie Mounts Remove the I O cable connector Figure Notes 1 Press tab down 393 Icda8fop RPY 021198 2 Pull connector forward Secure the I O cable connector Icda9fop RPY 021398 Figure Notes 1 Press tab down Remove the fan cover 394 Icda3fop EWS 110398 Install the Pass Thru Kit_ Begin Return to Task List 1 Snap the beige SC SC fiber optic adapter onto the pass thru tool See Fiber optic adapter and pass thru tool Use the beige adapter even if single mode fiber is being installed The beige adapter is better suited for cable routing in the next steps If single mode fiber is being installed the beige adapter will be replaced with a blue ada
125. 0000000000000 Ej BRUGES pee ae ee oF j n 1 Q Uo 0003 1 PDH 062596 Figure Notes 1 Wall Mounting Plate 2 Battery 1149B Shown 3 1146B Power Distribution Unit 4 1145B Power Unit 5 Power Cable 6 Unswitched Outlet 120 VAC 20 Amp or 230 VAC 15 Amp 7 Battery Backup Switch Setting Expanded Power Distribution Unit 1149 Battery 0000000000000000 Battery Reserve 1145 Power Unit Charging Battery Output Power On 000000000000000 0 eee ee 0004_1 PDH 062596 Figure Notes 1 Wall Mounting Plate 2 Second 1146B Power Distribution Unit 3 Cable H600 347 G7 4 First 1146B Power Distribution Unit 5 1145B Power Unit Important Warning for 1145B Power Supply Return to Task List WARNING Important Safety Instructions follow When operating this equipment basic safety precautions must be followed to reduce the risk of fire electric shock and personal injury including the following Read and understand all instructions Do not attach the power supply cord to building surfaces For continued back
126. 002 2 T 2 3 W O 27 103 R 2 4 O W 02 003 422 Port 10 11 12 13 14 15 16 17 18 19 20 Signal T 3 R 3 T 4 R 4 T 5 R 5 T 6 R 6 T 7 R 7 T 8 R 8 T 9 R 9 T 10 R 10 T 11 R 11 T 12 R 12 T 13 R 13 T 14 R 14 T 15 R 15 T 16 R 16 T 17 R 17 T 18 R 18 T 19 R 19 T 20 R 20 Cross Connect Pin 5 o OD Color W G G W W BR BR W W SL SL W R BL BL R R O O R R G G R R BR BR R R SL SL R BK BL BL BK BK O O BK BK G G BK BK BR BR BK BK SL SL BK Y BL BL Y Y O O Y Y G G Y Y BR BR Y Y SL SL Y 423 Amphenol Pin 28 03 29 04 30 05 31 06 32 07 33 08 34 09 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 104 004 105 005 106 006 107 007 108 008 109 009 110 010 111 011 112 012 113 013 302 202 303 203 304 204 305 205 306 206 307 207 308 208 309 209 Port 21 22 23 24 Signal T 21 R 21 T 22 R 22 T 23 R 23 T 24 R 24 Color AmphenolPin Backplane Pin in 41 V BL 46 310 42 BL V 21 210 43 V O 47 311 44 O V 22 211 45 V G 48 312 46 G V 23 212 47 V BR 49 313 48 BR V 24 213 DS1 Interface Cable H600 307 Begin 50 Pin 15 Pin Pin Color Designation Pin Color Designation 02 W BL 03 BL W 47 W G LI High 11 W G LI High 22 G W LI 03 G W LI 48 W BR LO 09 W BR LO 23 BR W LO High 01 BR LO High 49 W SL LOOP2 06 W S
127. 01 01 04 Menu Status CR ONLY OFF USA UK GE LINE DRAWING ALL RECEIVE OFF RTS OFF OFF 256 8 XON XOFF 1 1200 The interface between the system and Call Detail Recording CDR equipment may be one of the following Data Module Recommended option settings are shown in Options for D Lead and Attention Control Modems Modem Recommended option settings are in modem vendor document TN726 Data Line circuit pack and an Asynchronous Data Unit Data modules or modems are not required Connected directly to the DCE connector Electronic Industries Association EIA Port located on the rear of the Control Carrier Data modules or modems are not required A 572 Printer can be used as an output receiving device for Call Detail Recording CDR The recommended option settings for this printer are shown in 572 Printer Used with Management Terminal CDR and Journal Printer and 572 Printer Used as System Printer Also a TELESEER Call Detail Recording CDR 94A Local Storage Unit LSU or Customer Premises Equipment CPE can be used as the output receiving device 374 Options for D Lead and Attention Control Modems D Lead Settings Set Option Display Set 300 Speed Set 1200 Speed Set 2400 Speed Set 4800 Speed Set 9600 Speed Set 19200 Speed Set AT Control Set CI Lead Set CI2 Lead Set CH Lead Set CH2 Lead Set LL Lead Set REMOTE Loop Set RL Lead Set SIGLS Disc
128. 02185 6 0F 6 0Y 49 1 544 digital interface 04DU9 BN 6 0F RJ48C 1KN 1SN RJ48M 120A2 channel service unit 04DU9 DN 6 0Y RJ48C If the terminal equipment for example the media server or media gateway causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary The telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service If trouble is experienced with this equipment for repair or warranty information please contact the Technical Service Center at 1 800 242 2121 or contact your local Avaya representative If the equipment is causing harm to the telephone network the telephone company may request that you disconnect the equipment until the problem is resolved A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA A compliant telephone cord and modular plug is provided with this product It
129. 04 TN746 B 05 06 TN771 C 07 TN464 F 08 TN2140 09 TN767 E 10 TN799 B CIRCUIT PACKS 1 Carrier Carrier Type processor Sf Mode Name Slot Code Sf Mode Name 11 MEDPRO RESERVED IP DIGITAL LINE 12 MEDPRO RESERVED IP POOLED MODEM 13 TN802 B MAPD BOARD ANALOG LINE 14 ANALOG LINE 15 16 MAINTENANCE TEST DS1 INTERFACE E amp M TIE TRUNK DS1 INTERFACE CONTROL LAN d indicates circuit pack conflict Return to Task List Log onto the TN802B Interface Server Begin Return to Task List Note Use the attached keyboard mouse and monitor for the following administration To log on remotely through pcANYWHERE 1 Dial in to the server through pcANYWHERE using the dialup number supplied WARNING When connected remotely via pcCANYWHERE use only the pcANYWHERE Restart Host Computer button on the toolbar to restart Windows NT 2 Click on the pcCANYWHERE Remote Host Computer button on the toolbar To log on locally using the monitor keyboard and mouse 1 Press Ctrl Alt and Del simultaneously 263 To complete the logon steps 1 Type administrator in the User Name field 2 Type iptrunk in the Password field and click OK 3 After logging on for the first time change the administrator password and if desired the user name to ensure security See your Windows NT server documentation for details Return to Task List Change Mu Law to A Law for systems using A Law companding only Begin Retu
130. 1 Converter in critical reliability systems duplicated PNC Check System Status for Each Cabinet Begin Return to Task List The system status may suggest problem areas Specific tests later provide more specific diagnostic information 1 If Multi Carrier Cabinet MCC1 type status system cabinet number 1 44 and press Enter or If Single Carrier Cabinet SCC1 type status system all cabinets and press Enter 2 Verify the screen displays system status screens similar to Sample System Status Screen for Cabinet 1 Page 1 of 3 and to Sample System Status Screen for Cabinet 2 Page 2 of 3 Verify these service states Screen Field Service page section State Page 1 section1 Tone Clock in Page 1 section2 in 1 section3 EXP LINK in Page 2 section1 Tone Clock in for Cabinet 2 Page 2 section2 in for Cabinet 2 Page 2 section 3 EXP LINK in for Cabinet 2 129 cabinet carrier slot numbers for the fiber optic cables are listed For example 01A01 in Sample System Status Screen for Cabinet 1 Page 1 of 3 refers to cabinet stack 01 carrier A and slot 01 Sample System Status Screen for Cabinet 1 Page 1 of 3 status system all cabinets Page 1 of 3 SPE AN SYSTEM STATUS CABINET 1 SELECT SPE ALARMS TONE SERVICE SYSTEM SYSTEM SPE MODE SWITCH MAJOR MINOR CLOCK STATE CLOCK TONE 1A active auto 0 0 1A in standby standby 1B maint init auto 0 0 1B in active active SERVI
131. 1 CONVERTER FACILITIES A B Facility Installed yes no no no Passes Far end Clock yes yes yes yes Digital Data Compatible yes yes yes yes Line Coding ami zcs ami zcs ami zcs ami zcs Framing Mode esf esf esf esf DS1CONV 1 Line Compensation 1 1 1 1 DS1CONV 2 Line Compensation 1 1 1 1 Facility A Circuit ID 09876543 gt Distance to DSX 1 Interface feet Equalizer 22 AWG ABAM amp 24 AWG PDS 26 AWG PDS Seiting 1 1 to 133 0 to 90 2 133 to 266 90 to 180 409 Distance to DSX 1 Interface feet Equalizer 22 AWG amp 24 AWG PDS 26 AWG PDS Setting 3 266 to 399 180 to 270 4 399 to 533 270 to 360 5 533 to 655 360 to 450 Return to Task List Duplicated DS1C Converter Complex Administration for TN574 Circuit Packs Return to Task List Fiber Link Administration form for TN574 Circuit Pack Duplicated DS1 Converter Complex Administration page 3 of 3 allows you to admininster the DS1 converter Page 3 appears when the Is one endpoint remoted via a DS1 Converter Complex field is yes and duplication is enabled Note When you administer DS1 Converter TN1654 circuit packs different fields display For field definitions of the fields displayed on page 3 of the Fiber Link Administration form see DS1C Converter Complex Administration for TN574 Circuit Packs Fiber Link Administration form for TN574 Circuit Pack Duplicated DS1 Converter Complex Administration page 3 of 3
132. 1 Converter complex Bit Rate displays only under Facility A To activate the desired Bit Rate the toggle switch on the circuit pack must be set and it must correspond to the Bit Rate 412 Idle Code MSB 1 LSB 8 Displays when the 051 Converter circuit pack is TN1654 Enter 8 digits each digit must be 0 or 1 The second digit must be 1 Default is 11101000 You can administer this field on a per circuit pack basis e CRC Displays when the 051 Converter circuit pack is TN1654 and the Bit Rate is 2 048 Mbps Enter yes to receive a yellow 2 alarm for E1 operation Default is no You can administer this field on a per circuit pack basis Line Termination A display only field for 051 Converter circuit packs that are TN1654 and have a Bit Rate of 2 048 Mbps It identifies facility connections as CEPT 75 ohm coaxial or 120 ohm CEPT twisted pair Fiber Link Administration form for E1 TN1654 Circuit 051 Converter Complex Administration page 2 of 3 m add fiber link next Page 2 of 3 gt FIBER LINK ADMINISTRATION A PNC 051 CONVERTER DS1CONV ATTRIBUTES DS1CONV Board Location 01B01 DS1CONV Board Location 02B01 DS1CONV Board Type TN1654 DS1CONV Board Type TN1654 DS1 CONVERTER FACILITIES A B Facility Installed yes yes yes no Bit Rate 2 048 Facility Startup Idle Code 11101000 Line Coding hdb3 hdb3 hdb3 hdb3 CRC yes Line Termination Facility Circuit ID 09876543 Facility B Cir
133. 1 V O 43 TREF1 BL W 2 O V 44 To Y Cable Clock End Secondary RREF2 W O V O 43 TREF2 O W O V 44 322 Cross Connects for Standard Reliability From Stratum 3 Clock To Y Cable Clock End Primary Lead Lead Connecting Lead Lead Connecting Designation Color Block Designation Color Block Terminal Terminal To Tone Clock Carrier A BCLKRTN R O 13 ALRM5B V G 45 BCLKLST O R 14 ALRM5A G V 46 BPWRRIN R BR 17 ALRM4B BK BL 21 BPWRLST BR R 18 ALRM4A BL BK 22 REF2RTN W BR 7 ALRM3B R BR 17 REF2LST BR W 8 ALRM3A BR R 18 SCLKRTN R BL 11 ALRM2B R BL 11 SCLKLST BL R 12 ALRM2A BL R 12 SPWRRIN R G 15 ALRM1B Y BL 31 SPWRLST G R 16 ALRM1A BL Y 32 REF1RTN W G 5 ALRMOB W BR 7 REF1LST G W 6 ALRMOA BR W 8 CCAO1R R S 19 EXTSYNOT V BL 41 CCAO1T S R 20 EXTSYNOR BL V 42 CCBO1R BK BL 21 EXTSYN1T Y G 35 CCBO1T BL BK 22 EXTSYNIR G Y 36 Cross Connects for High or Critical Reliability From Stratum 3 Clock To Y Cable Clock End Primary Lead Lead Connecting Lead Lead Connecting Designation Color Block Designation Color Block Terminal Terminal RREF1 W BL 1 V O 43 TREF1 BL W 2 O V 44 To Y Cable Clock End Secondary W O 3 V O 43 Lead Lead Connect Designation Color ing O W 4 O V 44 Block Terminal To Tone Clock Carrier B ALRM5B ALRM5B V G 45 ALRM5A ALRM5A G V 46 BPWRRTN R BR 17 ALRM4B BK BL 21 ALRM4B BK BL 21 BPWRLST BR R 18 ALRM4A BL BK 22 ALRM4A BL BK 22 REF2RTN W BR 7 ALRM3B R BR 17 ALRM3B R BR 17 323 Cross Connects for High or Crit
134. 1 only Begin Return to Task List 1 Type reset system 4 and press Enter 2 Login as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 3 About 8 minutes after booting type status spe and press Enter 4 Verify that handshake shadowing and refreshed are all shown to be either yes or on 118 Enable Duplication and Boot Critical Reliability System Avaya DEFINITY Server r Begin Return to Task List 1 Type change system parameters duplication and press Enter 2 Make sure duplication of both SPE and PNC are enabled on the screen that follows the command Confirm that y is the value in both fields 3 Type save translation and press Enter 4 Type reset system 4 and press Enter to reboot the system 5 Login as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 6 About 8 minutes after booting the system type status spe and press Enter 7 Verify that handshake shadowing and refreshed are all shown to be either yes or on Return to Task List Administer Attendant Console Begin Return to Task List 1 Log in as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 2 Type display system parameters country options and press Enter to verify the System s companding mode for its local stations is set to the desired value usua
135. 17 18 22 31 Function Name FORM LENGTH LPI CPI LQ or NLQ BUZZER FONT RESOLUTION BUFFER PW ON MODE DIRECTION BUFF FULL P E AUTO CARRIAGE RETURN CR ZERO AUTO LINE FEED 1 SKIP 376 01 01 02 01 03 07 01 02 01 02 02 02 02 03 01 01 01 Menu 09 01 01 01 01 02 01 02 01 01 02 01 01 01 01 01 CR ONLY OFF USA UK GE LINE DRAWING ALL RECEIVE OFF RTS OFF OFF 256 8 XON XOFF 1 9600 Menu Status 11 6 10 LQ ON FONTCART 144 N LINE ON LINE B1 DIR 1 LF CR ACTIVE CR LF 0 CR ONLY OFF Table 4 572 Printer Used as System Printer Function Function Name 32 CHAR SET GO GL 33 CHAR SET G1 GR 34 CHAR SET G2 35 CHAR SET G3 81 OFF LINE STATE 82 DSR 83 REQUEST TO SEND RTS TIMING 84 CD 85 CLEAR TO SEND CTS 91 OVER RUN 92 DATA BIT 93 PROTOCOL 94 STOP BIT 95 PARITY 96 PBS Return to Task List AUDIX Interface Option Settings Return to Task List Menu 02 01 03 07 01 02 01 02 02 02 02 03 01 01 04 Menu Status USA UK GE LINE DRAWING ALL RECEIVE OFF RTS OFF OFF 256 8 XON XOFF 1 1200 The Audio Information Exchange AUDIX is sometimes connected to the system through the TN765 Processor Interface circuit pack The first circuit on the processor interface can be connected directly to the AUDIX through the PI connector on the rear of the control carrier
136. 2 W S 30 T12 PXR3 5 TXT3 S W 05 R12 PXT3 R5 TXR3 R BL 31 E2 TXT3 T6 PXT3 BL R 06 C2 M2 TXR3 R6 PXR3 R O 32 A3 T3 T3 PXR4 T7 TXT4 O R 07 B3 R3 R3 PXT4 R7 TXR4 R3 R G 33 T13 TXT4 T8 PXT4 G R 08 R13 TXR4 R8 PXR4 R BR 34 E3 PXR5 TXT5 BR R 09 C3 M3 PXT5 R9 TXR5 417 Color Con DID Tie DS1 ISDN ISDN Packet 4Port nector Trunk DIOD Trunk Tie BRI BRI Data DIOD Pin Nos 3 wire Trunk Trunk Line Line Line 4 wire 2 wire R S 35 A4 T4 T4 TXT5 T10 PXT5 4 S R 10 B4 R4 R4 TXR5 R10 PXR5 R4 BK BL 36 T14 PXR6 T11 TXT6 BL BK 11 R14 PXT6 R11 TXR6 BK O 37 E4 TXT6 T12 PXT6 O BK 12 M4 TXR6 R12 PXR6 BK G 38 T5 PXR7 TXT7 G BK 13 R5 PXT7 TXR7 BK B 39 TXT7 PXT7 R BR B 14 TXR7 PXR7 K BK S 40 PXR8 TXT8 S BK 15 PXT8 TXR8 Y BL 41 T6 TXT8 PXT8 BL Y 16 R6 TXR8 PXR8 Y O 42 PXR9 TXT9 O Y 17 PXT9 TXR9 Y G 43 TXT9 PXT9 G Y 18 TXR9 PXR9 Y BR 44 T7 PXR10 TXT10 BR Y 19 R7 PXT10 TXR10 Y S 45 TXT10 PXT10 S Y 20 TXR10 PXR10 V BL 46 PXR11 TXT11 BL V 21 PXT11 TXR11 V O 47 T8 LI TXT11 PXT11 22 R8 LI TXR11 PXR11 V G 48 LO PXR12 TXT12 G V 23 LO PXT12 TXR12 V BR 49 LBAC TXT12 PXT12 K2 BR V 24 LBAC TXR12 PXR12 K1 V S 50 S V 25 418 The wire colors in this chart apply only to B25A and A25B cables H600 307 cable colors are not shown The following wire colors apply to this chart White S Slate Grey BL Blue R Red BK Black G Green Y Yellow BR Brown V Violet The following abbreviations apply for all circ
137. 2 23 24 25 8 Port Analog 8 Port CO 8 Port Data Line 8 Port DID 8 Port Digital 8 Port Hybrid 12 Port BRI 16 Port Analog 1 A OBE 2 et ae ae OO 16 Port Digital 24 Port Analog 24 Port Digital 1 188 OBE 2 2 ae ae OO ae 24 32 Channel DS1 widfccf3 KLC 020802 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 MDF Cross Connect Fields Each Main Distribution Frame MDF contains a trunk auxiliary field and a distribution field The trunk auxiliary field contains three cross connect areas The green field terminates the network interface leads from the Central Office CO and provides the terminals to cross connect the leads to the purple or yellow fields as required A single row of the 110 type terminal block can terminate twenty four 1 pair eight 3 pair or twelve 2 pair trunks purple field terminates the trunk circuits from the system with WP 90929 List 1 or 3 concentrator cables Also 25 pair cables can be used to terminate trunk circuits from the system with each trunk circuit pack connecting to one 25 pair row of the 110 type terminal block Each terminal block row can terminate twenty four 1 pair eight 3 pair or twelve 2 pair trunks The yellow field provides cross connect terminals for all miscellaneous leads from the system such as alarm monitors emergency transfer rel
138. 20599 Figure Notes 1 Typical Display Telephone 2 Individual Power Supply Such as 1151A1 or 1151A2 3 Information Outlet Modular Jack 4 4 Pair D Inside Wire DIW Cable 5 Satellite Site or Adapter Location 180 6 25 Pair D Inside Wire DIW Cable 7 Station Side of Main Distribution Frame MDF 8 100P6A Patch Cord or Jumpers 9 System Side of Main Distribution Frame MDF 10 25 Pair Cable to System Cabinet Analog Line Circuit Pack 11 Equipment Room 12 Satellite Location 13 Work Location 14 Bulk Power Supply Such as 1145B Return to Task List 181 182 Install and Wire Telephone Power Supply This section provides information and wiring examples of installation procedures for various telephone and console power supplies These are examples only and actual wiring procedures may vary at each site Note Refer to the nstallation and Adjuncts and Peripherals for Avaya Communication Manager to install the necessary peripheral equipment Task List Power Supplies For 1145B Power Supply see Important Warning for 1145B Power Supply Install the Wall Mounting Plates Mount the 1146B Power Distribution Unit Install the Battery Mounting Wiring Install the Expanded Power Distribution Unit Power Up and Test the Power Supply Wire the 1146B Power Distribution Unit Reset LEDs on Power Distribution Unit For 1151A1 and 1151A2 Power Supplies see Important Safety Instructions for 1151A1 and 1151A2 Power Supplies
139. 227 240 C LAN connection testing 360 C LAN installing 237 C LAN distributed firmware download procedure 342 cleaning fiber optic cables 390 closets site locations 61 CO trunk 380 CO trunk pinouts 415 CO trunk wiring 143 CO trunk3 wire pinouts 417 CO trunks 296 code calling access 216 collocated DS1 tie trunks wiring 146 commands introduction 92 COMSPHERE modem 370 concentrator cables connecting trunk pairs 75 concrete encased ground 383 concrete floor mounting 21 conductor coupled bonding 60 connectable administration terminals 70 connectable terminals 139 connectable voice and data terminals 69 connecting AC power 31 37 connecting AC power to DC power cabinet 37 427 Index connecting battery leads 28 connecting cabinet grounds 34 connecting control carrier outputs cable 75 connecting DC battery and power cabinet grounds 37 connecting DC power to cabinets 39 connecting external alarm cable 42 connecting external alarm indicators 156 connecting fiber optic cable 45 385 critical reliability CSS system 47 high reliability CSS system 46 standard reliability CSS system 45 connecting ground wires DC systems 38 connecting large battery holdover 29 connecting mixed AC DC power and ground 40 connecting remote power off cable 41 connecting small battery holdover 29 connecting TN1654 through CSU 311 connecting to the DEFINITY ECS 97 98 99 connection diagrams station cables 65
140. 3 3 Federal Communications Commission Statement Part 15 Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Part 68 Answer Supervision Signaling Allowing this equipment to be operated in a manner that does not provide proper answer supervision signaling is in violation of Part 68 rules This equipment returns answer supervision signals to the public switched network when answered by the called station answered by the attendant or routed to a recorded announcement that can be administered by the customer premises equipment CPE user This equipment returns answer supervision signals on all direct inward dialed DID calls forwarded back to the public switched telephone network Permissible exceptions are A call is unanswered A busy tone is received A reorder tone is received Avaya attests that thi
141. 302AP circuit pack upgrading to 242 N2302AP upgrading firmware on 341 N2302AP upgrading from TN802B IP interface assembly 243 244 245 N2302AP upgrading to 242 N2464 circuit pack 380 N2464BP 230 N2464BP upgrading firmware on 341 N2501AP reseating and resetting 351 N2501AP integrated announcements faceplate LEDs and interpretation 210 N2501AP upgrading firmware on 341 3455 3533553 3533535 3335 d gd TN429 circuit pack 287 TN464 circuit pack 380 TN464GP 230 TN464GP upgrading firmware on 341 TN574 DS1 converter circuit packs 407 TN574 DS1 converter complex circuit packs 410 TN750 circuit pack 213 214 215 TN750 B C adding 212 TN750C circuit pack 214 TN750Ccircuit pack 215 TN760 circuit pack option settings 378 TN771DP upgrading firmware on 341 TN793B circuit pack pinouts 422 TN799B 224 TN799B circuit pack 360 TN799B C LAN 236 249 TN799B C circuit pack 237 238 TN799DP upgrading firmware on 341 TN802 B 233 TN802B external cable assembly 247 257 test external connection to LAN 271 test onboard LAN connections 271 TN802B circuit pack change Mu Law to A Law 264 test external connection to LAN 255 TN802B circuit pack testing external LAN connection 255 TNS802B IP interface upgrading to 272 273 275 217 TN802B installing in IP trunk mode 256 257 258 259 260 261 262 263 264 265 267 270 271 TN802B installing in MedPro mode 246 248 249 250 253 2
142. 4 2 VDC 29 1 Connect the 48 VDC cable to the large battery connector See Power Distribution Unit J58890CH 2 Connect the 48 VDC RETURN cable to the ground terminal block 3 Connect the temperature sensor cable from the battery cabinet to J20 Note An adapter cable may be required when connecting the temperature sensor cable to the J58890CH unit See Temperature Sensor Cable Adapter Cables Power Distribution Unit J58890CH NN 010 020599 Figure Notes 1 Connect small battery holdover cable or temperature sensor cable from large battery cabinet to J20 2 Carrier Circuit Breakers 3 Ground Terminal Block 4 Connect 48 VDC Return 1 AWG 50 mm red cable here 5 Connect 48 VDC 1 AWG 50 mm black cable 6 1 AWG 50 mm 50 ft 15 2 m cable to large battery cabinet For cables greater than 50 ft 15 2 m contact your Avaya representative 7 Ground Terminal Block 8 To AC load center or approved single point ground block Temperature Sensor Cable Adapter Cables H600 476 Adapter Cable Usage Group 1 G1 24 cell customer provided battery Group 3 G3 included 24 cell Avaya battery with battery cabinet Return to Task List 30 Connect Shorting Cable to J58890CE 2 Begin Return to Task List A CAUTION For a cabinet with a battery charger read the caution label on the 397C battery charger before disconnecting batteries Some cabinets contain a J5
143. 46xx series IP telephones or wireless LAN WLAN access points This unit is used with a 10 100BaseTx standard Ethernet network over a standard TIA EIA 568 Category 5 6 or 6e cabling plant The 1152A1 meets the current requirements of the IEEE802 3af standard for resistive detection The 1152A1 PDU complies with the Underwriters Laboratories Inc UL standard UL 1950 second edition Complies UL 1950 Approved CSA C22 2 No 950 Std Approved CE Regulatory Compliance Approved EN 60950 Approved TUV EN 60950 For safety instructions see Important Safety Instructions for 1151A1 and 1151A2 Power Supplies on page 196 1151A1 and 1151A2 Power Supplies Return to Task List The 1151A1 and 1151A2 Power Supplies comply with the UL Standard UL 1950 second edition Complies UL 1950 Certified CSA 22 2 Approved EN6950 Approved CE For safety instructions see Important Safety Instructions for 1151A1 and 1151 2 Power Supplies For installation instructions see Connect the 1151A1 or 1151A2 Power Supplies Using 1151A1 and 1151A2 Power Supplies The 1151A1 and 1151A2 Power Supplies can be used to supply local power to ISDN T 65xx 74xx 75xx 84xx and 85xx series voice terminals connected to a system and to the 302C1 Attendant Console that requires auxiliary power for its display The unit can supply power to adjunct equipment such as S201A and CS201A speakerphones or a 500A Headset Adapter attached to any currently manufactured analo
144. 47 Firmware Download fields and descriptions lt Blueltalic9 gt Continued lt BlueDingbat9 gt Field Description Notes Schedule Type y to schedule the Once the firmware download Download firmware download for begins you cannot make any Remove Image Fil After Successful Download another time Type n to start the firmware download immediately after completing the form Type y if you want the procedure to automatically remove the new firmware image file default Type n if you do not want the new firmware image file removed changes to this form You can only disable this schedule using disable firmware download and then start a new one See Aborting a firmware download on page 352 for instructions If you answer n o then the Start Date Time and Stop Date Time fields disappear The download begins as soon as you press Enter At the completion of a successful download the procedure automatically removes the new firmware image file from the source file system freeing up the memory on the source circuit pack We recommend using the default setting If field is set to n you must manually remove the new firmware image file from the source file system after the download has completed See Disable file system on page 352 for instructions Continued on next page 348 Firmware Download fields and descriptions lt Blueltalic9 gt Continued lt BlueDingbat9 gt Field Description Note
145. 4C3S 75 is equipped with a heat coil for sneak current protection and the ITW Linx is equipped with replaceable fuses for sneak current protection Note The TN2181 16 Port Two Wire Digital Line circuit pack may not be approved for some out of building uses Contact your Avaya representative for more information The 4C3S 75 may be used only with Vintage 14 or newer TN754 circuit packs or TN754B circuit packs Digital Voice Circuit Protectors lists the approved protectors When possible all new and reused wiring installations should use blocks that accept the standard 5 pin plug in 4C3S 75 protector However there are reused wiring installations where this may not be cost effective For these installations the ITW Linx protector may be installed An example of this is where screw type carbon block protectors or other non plug compatible types are in place and it is too costly to re terminate the outside plant cable on a 5 pin mounting block for only a few out of building terminals Installing the ITW Linx Enhanced Protector The ITW Linx Enhanced Protector can be installed in series with existing primary protection The ITW Linx Enhanced Protector mounts directly on connecting blocks and requires a separate ground bar Installing the 4C3S 75 Enhanced Protector The 4C3S 75 protector cannot be installed in series with other types of primary protection It must be installed as the only protection on the line entering the build
146. 5 Either Type 5 Unprotect Type 1 ed Compatible Protected Type 1 Compatible Unprotect Type 1 ed Compatible Protected Type 1 Compatible TN760D Option Switch Settings and Administration Installation Situation Preferred Signaling Set E amp M Format SMPLX z V Option Circumstance To System Far End Switch Unit Co Located Net E amp M AnyPBX E amp M Integrated 1 Standard Return to Task List TN464 2464 Option Settings Return to Task List Set Prot Unprot Option Switch Unprotect ed Administered Port Type 1 The TN464 2464 DS1 E1 Interface T1 E1 circuit pack interfaces between a 24 or 32 channel CO ISDN or tie trunk and the Time Division Multiplexing TDM bus Set the switches on the circuit pack to select bit rate and impedance match See Option Switch Settings on TN464 2464 and TN464 2464 Option Settings Option Switch Settings on TN464 2464 120 ohms Twisted pair 75 ohms Coaxial requiring 888A adapter 32 channel 2 048 Mbps 24 channel 1 544 Mbps TN464 2464 Option Settings 0000000000000 Figure Notes 1 Backplane Connectors 2 24 32 Channel Selector 3 75 120 ohm Selector 380 4 5 32 Channel 6 120 ohm shown selected 7 24 Channel shown selected 8 75 ohm 9 Connector 10 TN464 2464 Return to Task List 381 382 Approved Grounds An approved ground is the closest acce
147. 5 telephone calls making test calls 355 telephone pin designations 144 151 159 telephones emergency transfer 175 176 telephones connecting 142 telephones testing 355 terminal alarm notification alarms 126 terminal blocks frame mounting 82 terminal blocks wall mounting 79 terminals connecting 65 terminating resistor 203 terminating trunk transmission test types 360 test other equipment 355 434 Index telephones 355 test circuit packs LEDs 127 test external connection to LAN C LAN 227 240 IP Media Processor 240 TN802B 271 TN802B circuit pack 255 test inads link command 358 test types terminating trunk transmission 360 testing data module hardware connections 101 testing fiber optic cable MCCI 402 testing the system 125 Thailand country code 113 three phase VAC power 24 tie trunk analog wiring 145 circuit pack option settings 378 digital wiring 146 tie trunk pinouts 417 tie trunk adding 297 tie trunks 297 TILTWATCH indicators 18 time division multiplexor See TDM time set procedure 116 N1648B 330 N1654 circuit pack 305 N1654 DS1 converter circuit packs 411 412 413 N1654 DS1 converter circuit packs duplicated 411 N2185B circuit pack pinouts 421 N2198 circuit pack pinouts 422 N2214CP upgrading firmware on 341 N2224CP upgrading firmware on 341 N2302AP 233 installing 233 236 software limits 234 required hardware 235 N2302AP circuit pack 237 238 N2
148. 55 tone clock boards testing 132 tone clock interchange testing 135 tone clocks service state 129 tone clock circuit packs LEDs 127 tone clock testing 135 transfer emergency testing 358 trunk cables installing 58 trunk pairs connecting with concentrator cables 75 trunk pairs connecting with jumper wires 76 trunk transmission testing 360 trunks CAMA E911 285 287 288 289 290 291 292 296 DID 296 DS1 298 299 300 301 302 435 Index 296 ISDN PRI 294 295 296 OPS 298 299 300 301 302 PCOL 296 tie 297 TTC Japanese 2 Mbit 304 WATS 296 TTC Japanese 2 Mbit trunks 304 U U S Robotics modem DIP switch settings 99 U S Robotics modem 328 329 uniform call distribution testing queue warning indicator 357 United Kingdom country code 113 upgrade IP interface assembly to IP Media Processor 243 IP Trunking to IP Media Processor 241 IP trunks to H 323 trunks 274 TN722 to TN767C 299 TN802 to TN802B 272 275 upgrade firmware programmable circuit packs 341 N2214CP 341 N2224CP 341 N2302AP 341 N2464BP 341 N2501AP 341 N464GP 341 N771DP 341 N799DP 341 USA country code 113 USR 33 6 EXT external modem 328 329 V verifying system start up messages 105 voice and data terminals connectable 60 voice terminals connectable 139 voice terminals exposed environments 165 wall mounting plates 188 water pi
149. 61 2 Atthe Main Distribution Frame MDF connect jumper wires between one row connecting block in the green field and up to three rows connecting blocks in the purple field to concentrate the analog line pairs 3 Connect an A25D cable between the sneak fuse panel and the terminal block connector associated with the green row in the previous step 4 Install a green label on the terminal block to identify the remote location 5 Administer per the Administrator s Guide for Avaya Communication Manager Return to Task List Off Premises or Out of Building Stations Return to Task List Out of building campus stations are telephones voice terminals not physically located in the same building as the equipment room but located on the same property Only analog telephones connected to TN742 TN746B TN2183 or TN769 Analog Line circuit packs can be installed out of building Task List Off Premises Requirements Off Premises Connections Off Premises Protection Requirements Voice Terminal Restrictions for Exposed Environments e Digital Out of Building Voice Terminal Protection Off Premises Connections Return to Task List Connections for 1 to 8 Out of Building Analog Telephones shows the connections for 1 to 8 off premises analog telephones Connections to 24 Out of Building Telephones shows the connections for up to 24 off premises analog telephones Concentrations of analog line pairs are used at both buildings to minimize the
150. 8890CE 2 AC Power Distribution Unit without an optional battery charger Install the shorting cable only when a battery charger is not installed If you do not install the shorting cable or a battery charger then an alarm appears 1 Set the circuit breakers on the power distribution unit OFF See Shorting Cable Installation 2 Atthe rear of the cabinet insert the shorting cable H600 442 G1 into J11 The cable is keyed so it can fit only 1 way Shorting Cable Installation psdfsht KLC 111296 Figure Notes 1 Shorting Cable H600 442 G1 If Battery Charger is Not Installed 2 J11 Return to Task List Connect AC Power Begin Return to Task List 1 Set the main circuit breakers on the power distribution unit OFF 2 Connect cabinet AC line cords to the AC power receptacles Note Do not power up the system at this time 31 Connect DC Power and Ground Return to Task List A CAUTION Grounding of the system shall comply with the general rules for grounding contained in Article 250 of the National Electrical Code NFPA 70 For more information refer to Approved Grounds The grounding methods for the DC powered system are more complex than that of an AC powered system Typical Power and Ground for a DC Powered Cabinet shows a typical power and ground layout for a DC powered cabinet The size of the wire required for the 48 volt DC and 48 volt return must ensure the voltage supplied by the battery pl
151. 9 AC Power Strip 10 Floor Line Return to Task List Mount 110P type terminal blocks on a frame Begin Return to Task List The 900 pair 110P type terminal blocks and the associated patch cord troughs can also be mounted on a free standing floor mounted 1110A2 Apparatus Mounting Frame See 1110A2 and 1110C1 Apparatus Mountings 82 Each 1110 2 provides the space to mount 5 terminal blocks patch cord troughs on each side of the frame A cable support structure apparatus mounting 1110C1 mounts directly on top of the 1110A2 and provides support for all cables routed to and from the frame See Apparatus Mounting Frame Information 1110A2 and 1110C1 Apparatus Mountings Figure Notes 1781401 LJK 040896 1 1110C1 Apparatus Mounting 2 1110A2 Apparatus Mounting 3 76 in 193 cm 4 88 5 in 225 cm 5 43 5 in 110 5 cm Apparatus Mounting Frame Information Code Number 1110A2 1110C1 1110A1 2110A1 2110B1 Return to Task List 83 Description Apparatus Mounting Frame Cable Support Assembly End Dress Panel Top Dress Panel Bottom Dress Panel Install Cable Slack Managers Begin Return to Task List 1 Place the Z113A Cable Slack Manager against the wall under the MDF See Cable Routing Through Cable Slack Manager SCC1 Align the left side of the cable slack manager with the first terminal block of the trunk auxiliary field 2 Place the next cable slack manager beside the previo
152. 9600 bps modem connection for the remote management terminal The network interface trunk should appear on the twenty fifth pair of a RJ21X network interface jack The trunk is a two way rotary dial loop start trunk that connects to a maintenance circuit pack the processor circuit pack or the SYSAM circuit pack through the Remote Network Interface terminals at the trunk auxiliary field Connections at Trunk Auxiliary Field shows a typical Remote Network Interface trunk installation Task List Install the Remote Network Interface 1 Install the Remote Network Interface 2 Install Off Premises Station Wiring Connections at Trunk Auxiliary Field 1758482b RBP 062696 Figure Notes 1 To Network Interface Facility 2 To Control Carrier Auxiliary Connector 3 One Pair of Wires 4 Twenty fifth Pair of RJ21X Network Interface Jack Install the Remote Network Interface Begin Return to Task List You must obtain the product identification and the INADS OSS telephone number from the NTSO or the TSC before you begin to install the Remote Network Interface Connections at Trunk Auxiliary Field shows a typical Remote Network Interface trunk installation 1 Determine the network interface trunk appearance at the green trunk auxiliary field 2 Label the terminals for the trunk appearance 3 Install jumpers between the trunk appearance and Remote Network Interface terminals 160 4 Enter change system parameters mainten
153. A AC power 318 checking voltage 43 connecting 31 connecting to DC power cabinet 37 ground wiring 25 26 grounding 23 383 single phase 24 three phase 24 AC DC mixed power and ground 40 AC DC powered cabinet connecting 40 acceptance testing telephones 355 accessing the DEFINITY system 91 accessing the system 95 AC powered system power up 105 activating the system 91 103 adapter 258A 356A BR2580A ZD8AJ 63 451A extender 63 add translation 120 adding CallVisor ASAI 216 circuit packs 200 CO trunk 296 code calling access 216 CSU 27 DCS interface 224 225 226 227 229 DID trunk 296 DID trunks 296 DS1 tie trunks 298 external modem to EPN 328 external modem to PPN 329 external modem to TN1648B 330 FX trunk 296 ISDN PRI 294 295 296 OPS trunks 298 packet bus support R9si 219 220 221 224 PCOL trunk 296 pooled modem 336 speech synthesis 216 tie trunk 297 tie trunks 297 TN750 B C 212 TN750C 215 TTC Japanese 2 Mbit trunks 304 WATS trunk 296 425 Index adding CSU 282 adding data module to switch 101 additional hardware installing 199 adjunct power 142 143 152 administation terminals connectable 139 administering circuit packs 92 administering fiber links 405 administering fiber optic cable 403 administering IP trunk mode 262 administering MCCs 110 112 administering patch cords and jumpers 72 administering PNC duplication 404 administering the atte
154. A Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 4 and press Enter Wait until the system has completely reset before continuing Type change cabinet 1 and press Enter In the Carrier Type column change the B carrier to processor and submit the form Type change system parameters duplication and press Enter Set the Enable Operation of SPE Duplication field to y and submit the form Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 preserve license or reset system 3 no preserve license since the License File has been saved in translations and press Enter Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 and press Enter Wait until the system has completely reset before continuing If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints Type set time and press Enter Ensure that the system date and time are se
155. A through F and the jack appearance in the equipment room on the form Also enter the floor designation and or building designation if appropriate For 1 point administration this entry is all that is required The white label identifying the terminal block row associated with circuits 17 to 24 connects to an identically labeled terminal block row at the satellite closet See Example 3 Pair Labeling to Information Outlet This is always the case for either 1 point or 2 point administration The satellite symbol must be installed at all connection points between the blue field and the information outlet It must also be installed at the information outlet itself 2 Example 4 Pair Labeling to Information Outlet shows an example labeling scheme for 4 pair circuits from the equipment room to the information outlets The labeling scheme for 3 pair circuits from the MDF to a satellite location Port Assignment Record Form CARRIER PORT ASSIGNMENT RECORD Bags Extension Bldg Voice Voice Number Fir Terminal Terminal Slot Port Jack Old New P Color Module Power User Name Use 01 02 03 04 05 06 07 08 oo _ 10 __ Slot 12 _ 1 ll o y y 13 x LI a a a a a S S CKT PK _15 Type 16 _ l Too o o y y 17 19 20 21 22 23 24 To be completed by installation technician
156. A CAUTION The power circuit must be dedicated to the system and must not be shared with other equipment and must not be controlled by a wall switch The AC receptacle should not be located under the MDF A CAUTION System grounding must comply with the general rules for grounding contained in Article 250 of the National Electrical Code NEC National Fire Protection Agency NFPA 70 or the applicable electric code in the country containing the equipment For more information refer to Approved Grounds For information about connecting AC power and ground see e Power Requirements 23 Power Supply Sources J58890CE 1 J58890CE 2 and J58890CH 1 Grounding an AC Powered System J58890CE Connect Mixed AC DC Power and Ground Task List Connect AC power and ground Power Requirements Perform these tasks to connect AC power and ground 1 Ground AC Load Center 50 ft 15 2 m or Less from Cabinet or Ground AC Load Center More Than 50 ft 15 2 m from Cabinet 2 Connect Battery Leads J58890CH 1 3 Connect Small Battery Holdover or Connect Large Battery Holdover 4 Connect Shorting Cable to J58890CE 2 5 Connect AC Power DEFINITY System Power Requirements Maximum DEFINITY UL Rating Label Power Capacity Vac In lac In Max W In BTU Hr 208 24 3245 11071 26 240 21 3276 11177 71 120 40 3120 10645 44 Power Supply Sources J58890CE 1 J58890CE 2 and J58890CH 1 The connect AC power and ground procedures apply to the AC powered P
157. Avaya Communication Manager for specific information 1 Log in as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 2 Type change node names and press Enter See Node Names screen 3 On page 2 type in the node names and IP addresses for the TN799x and the TN2302AP Note The customer or design team provides the actual name and address Suggest a generic name and not one tied to the circuit pack 4 Type display circuit pack and press Enter Verify that the TN2302AP shows up in the Code column 238 change node names Name clan al clan b1 default mrmedprol 5 Type change ip interfaces and press Enter See IP Interfaces screen Note The customer provides the IP address subnet mask and gateway address 6 Type in the following information for the TN2302AP IP Media Processor and TN799x C LAN Set Slot field to UUCSS The Code and SFX fields are automatically populated with TN799x and TN2302AP In the Node Name field type the same node name entered on the Node Name screen In the Subnet Mask field use the default setting unless you are given a different subnet mask In the Gateway Address field use the address you are given or leave blank Set the Net Region field to 1 unless you are given a different number Set the Enable Eth Pt field to y 7 Press Enter to save the information and effect the new settings Refer to the A
158. BCS and 715 BCS 2 Management Terminal system Management Terminal administration and maintenance terminal The keyboards and terminals are interchangeable when an adapter cable is used 70 Note The older version of 715 BCT the 715 Business Communications System BCS 406803148 and 406803155 has a 6 pin mini DIN keyboard connector The new version of 715 BCT the 715 Business Communications System BCS 4073113881 and 407313899 has a 6 pin RJ 11 keyboard jack located on the side of the terminal Layout This section has information about e Information Outlet Locations e Site Satellite and Adapter Locations Sizing 4 Pair Station Cables e Sizing 25 Pair and Multiple 25 Pair Station Cables e 3 Pair Station Cable Circuits 4 Pair Station Cable Circuits Information Outlet Locations The customer or marketing representative must provide floor plans showing the information outlet locations and types flush or surface mounted required The floor plans must also show a complete overview of all conduit and cabling facilities in the building Site Satellite and Adapter Locations Use the following information when determining site satellite or adapter locations Keep the number of locations to a minimum minimize the station wiring distances centrally locate the sites satellites or adapters among the information outlets e Site satellite locations must be easily accessible and contain AC powered
159. BK G 38 48 G BK 13 GND BK BR 39 48 BR BK 14 GND BK S 40 48 S BK 15 GND Y BL 41 48 BL Y 16 GND Y O 42 48 O Y 17 GND Y G 43 Not Connected G Y 18 Y BR 44 GND BR Y 19 48 Y S 45 GND S Y 20 48 V BL 46 GND BL V 21 48 V O 47 Not Connected O V 22 V G 48 Ext Alarm A G V 23 Ext Alarm Return V BR 49 Not Connected BR V 24 V S 50 INADS Tip S V 25 INADS Ring Power Emergency Transfer Relay Power AUX Power 1 Color designation is the main wire color and the color of the stripe on the wire The following wire colors apply W White BL Blue O Orange G Green BR Brown S Slate Grey R Red Y Yellow V Violet External alarm with signal incoming to system External alarm with signal outgoing from system 150 Port Circuit Pack and Telephone Pin Designations Pin on 4 wire 2 wire 8510T Analog NT1 Z3A1 amp Modular 302C1 302C1 Basic Station Z3A2 Plug 8400 Seri 8400 Series Rate Modem Asynchro es 603E 603E Interface nous Data 9403 9403 9410 BRI Units 9434 9434 with ADU adjunct Data speaker Module phone 1 TXT TXT 2 TXR TXR 3 PXT TXT PXT 4 PXR 5 PXT No 6 PXR TXR aaa PXR 7 48VDC 48VDC 48VDC modular 48VDC 8 GRD GRD GRD jack GRD Circuit TN754 TN2181 TN556 TN2183 TN2198 TN726 Pack 4 wire 2 wire digital ISDN BRI Analog line 2 wire Data Line digital 8 16 port Line 16 port Basic port TN2224 Rate 2 wire digital Interface 24 port line PX PBX transmitT Tip A TX Termin
160. BX 25 OFF enable ON disable default 319 Switch 500 OFF ON OFF ON 1000 OFF OFF ON ON ST3 Clock Circuit Pack Option Switch Settings Switch Status Results SW1 OFF minor alarm never output Minor Alarm Control ON minor alarm is output if holdover occurs SW2 OFF major alarm is output and fail lamp lights if 5 VDC Major Alarm power is lost and 4 kHz output is lost Control ON major alarm is output and fail lamp lights if 5 VDC power is lost and 4 kHz output is lost and holdover occurs Note Only SW 1 and SW2 are used SW1 controls the output of alarm signals from the Stratum 3 Clock circuit pack Composite Clock Timing Output TOCA Circuit Pack Range 1 ft 500 ft 1000 ft 1500 ft 2000 ft 2500 ft 3000 ft 0 3 152m 305m 457m 610m 762m 914 p oe es ee ee m LE gt eee oes sneer gt aK ee ane OI ae RE gt Lapeer Aeniiaee aaRS gt Note Set switches 1 and 2 according to the distance from the Stratum 3 clock to the DEFINITY System Set switch 3 to ON Set switch 4 to OFF Return to Task List Cable the Stratum 3 Clock Begin Return to Task List Typical Connections to Stratum 3 Clock shows typical connections to a Stratum 3 Clock cabinet Connections are made through the yellow field cross connect A custom Y cable H600 274 connects the CSU to the DS1 circuit pack and taps off the input for the Stratum 3 Clock A resistor built into the cable to provides the nece
161. Begin 1 Return to Task List Log in as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password You may have to contact Avaya to get the dadmin password 2 3 A 6 7 Verify the screen displays password Type the default password and press Enter For security reasons the password is not displayed as it is typed The system verifies a valid login and password name were entered If an invalid login or password name was entered the screen displays login incorrect In this case repeat the procedure using the correct login and matching password If the system recognizes the login and password name the screen displays the software version Verify the screen display is similar to Terminal Type 513 715 4410 4425 VT220 715 Type the number of the management terminal and press Enter Verify the screen displays command Return to Task List Deliver or install the License File Begin Return to Task List A CAUTION This procedure must be done immediately after you upgrade the software If the license file is not installed within 10 days the switch enters a No License mode and shuts down all call processing 1 2 A Retrieve the RFA License File with both serial numbers from the RFA Application Type set time and press Enter Ensure that the system date and time are set correctly Use one of these installation methods
162. CAMA Trunk Group form page 1 in the Group Type field enter cama In the Group Name field enter the desired name In the TAC field enter the desired trunk access code In the Outgoing Display field enter y In the CESID I Digits Sent field enter the number directed by the Central Office CO or the Public Safety Answering Point PSAP Scroll to Administrable Timers form page 3 8 On the Administrable Timers screen page 3 you may need to adjust these fields according to your CO Scroll to Group Member Assignments form page 5 9 On the Group Member Assignments screen in the Port field add the trunk members and press Enter when finished A O N CAMA Trunk Group form page 1 y Group Number 1 Group Type cama CDR Reports y Group Name cama Trunk Group E911 COR 1 TN 1 TAC 701 Direction outgoing Outgoing Display y CESID I Digits Sent 0 ESID I Digits Sent 0 TRUNK PARAMETERS Trunk Type wink start Outgoing Dial Type rimf Trunk Termination rc Page 1 of 11 TRUNK GROUP Busy Threshold 99 Busy Threshold 99 Administrable Timers form page 3 288 1 N Page 3 of 11 TRUNK GROUP ADMINISTRABLE TIMERS Outgoing Disconnect msec 400 Cama Outgoing Dial Guard msec 75 Outgoing Glare Guard msec 1000 Cama Wink Start Time msec 5000 Outgoing End of Dial sec 1 Outgoing Seizure Response sec 4 C Disconnect Signal Error sec 30 Group
163. CE CONTROL DEDICATED SERVICE BUS ALARMS BUS OPEN BUS TDM STATE CHANNEL TONES PKT STATE MAJOR MINOR FAULTS LEADS 1A in y n 1 in 1B in n y EMERGENCY SELECT SERVICE CABINET TRANSFER SWITCH EXP LINK STATE MODE TYPE 1A auto on 01A01 02A01 in standby SCC 1B auto on 01B01 02B02 in active y Sample System Status Screen for Cabinet 2 Page 2 of 3 Status system all cabinets Page 2 of 3 SPE AN SYSTEM STATUS CABINET 2 SELECT SPE ALARMS TONE SERVICE SYSTEM SYSTEM SPE MODE SWITCH MAJOR MINOR CLOCK STATE CLOCK TONE 1A active auto 0 0 2A in active active 1B maint init auto 0 0 2B in standby standby SERVICE CONTROL DEDICATED SERVICE BUS ALARMS BUS OPEN BUS TDM STATE CHANNEL TONES PKT STATE MAJOR MINOR FAULTS LEADS 2A in y n 2 2B in n y EMERGENCY SELECT SERVICE CABINET TRANSFER SWITCH EXP LINK STATE MODE TYPE 2A auto on 01A01 02A01 in standby MCC 01B01 02B02 in active 130 Return to Task List Check Circuit Pack Configuration Begin Return to Task List The list configuration report provides a list of circuit packs connected to the system and recognized by the software 1 Type list configuration all and press Enter 2 Verify the screen displays list configuration similar to Sample System Configuration Screen Page 1 Make sure the software is communicating with each circuit pack except power supply circuit packs Do not attempt to correct any problems until after the diagnostic tests that you run later i
164. CHARGE bar 5 Route the CABINET GROUND wire to Control Cabinet and connect to the single point ground block Note If the EPN cabinet is located remote from the PPN cabinet in a separate room or building route the EPN CABINET GROUND wire to an approved protective ground 6 Repeat connecting each EPN cabinet to the single point ground block 7 Connect a 6 AWG 40 16 mm ground wire to an unused terminal on the single point ground block 8 Route the ground wire to the AC load center ground and connect Typical Cabinet Grounding Wiring Diagram i widfspgb KLC 100297 Figure Notes 1 PPN Cabinet 2 EPN Cabinet if Installed 3 6 AWG 40 16 mm CABINET GROUND Wire 4 Single Point Ground Block 5 6 AWG 40 16 4 mm Ground Wire to Approved Ground 6 AC Load Center Single Point Ground 7 Over 50 ft 15 2 m 27 8 Cabinet Ground Terminal Block Return to Task List Connect Baitery Leads J58890CH 1 Begin Return to Task List Typical Small Battery Assembly shows a typical optional small battery holdover assembly These assemblies may ship with the battery leads disconnected to prevent the batteries from discharging 1 Plug the battery connector into the 48 VDC Batteries connector on the rear of the J58890CH 1 Power Distribution Unit A CAUTION Power is present in the cabinet even if the AC power cable is unp
165. CSU module 700A DS1 loopback jack Cable H600 383 4 pair modular cord Group 2 50 foot 15 2 m cable standard Note If using cabling other than the H600 383 see H700 383 Equivalent Cable Guidelines Cord DW8A DE 4 pair modular cord to alarm contacts DS1 circuit pack The basic ICSU requires a TN464E or TN767D or later The enhanced integrated channel service unit can also be used with the TN2464 or TN2313 H700 383 Equivalent Cable Guidelines If using cabling other than the H700 383 provided with the 120A3A observe the following guidelines Use 24 gauge wire that provides individually shielded twisted pairs for transmit and receive signals Use the cable between the network interface and the 120A3A Ground the shields of this cable only at the 120A3A end to avoid ground loops Cabling between the network interface and 120A3A can have no bridge taps 279 If using standard house riser cable for connections between the network interface and the 120A3A maintain a 100 pair separation between the receive and transmit twisted pairs If using standard house riser cable for connections between the network interface and the 120A3A allow no more than 2 cross connects to 110 type cross connect blocks Never use quad cable untwisted two pair telephone cable in a DS1 line Avoid mixing wires of different gauges in a 051 line Installing the 120A3A CSU Begin 120A3A Channel Service Unit Module shows the co
166. Check that all selector console lamps are operational Make call to a telephone in the system 1 Simultaneously press and hold the Ringer Volume up button and the POS BUSY button on the attendant console This puts the console in the self test mode 2 Each row of lamps on the selector console lights and goes dark in sequence from top to bottom 3 Press hundreds group select button The hundreds group select lamp lights and any lamps associated with busy telephone light 4 Press Direct Extension Selection DXS button for the desired extension Audible ringing tone is heard in the earpiece on attendant console 5 On attendant console press Release Audible ringing tone is silenced Return to Task List Test External Ringing Begin Return to Task List 356 Make a test call to the attendant console to verify ringing device sounds when the Night lamp on console is lighted If ringing device has not been installed by customer connect spare telephone to information outlet reserved for ringing device and make test call Test Queue Warning Indicator Begin Return to Task List Make a test call to an extension associated with a Uniform Call Distribution UCD or Direct Department Calling DDC group and verify the queue warning indicator lamp lights If the queue warning indicator has not been installed by customer connect a spare telephone to the information outlet reserved for queue warning indicator and make a test call T
167. DC OUTPUT distribution bus on the DC Power Cabinet 4 Atthe DC Battery Cabinet connect the 48 volt DC wire to the 48 VDC connector 5 Route the wire out of the cabinet through the hole in the lower rear cover and to the DC Power Cabinet 6 Atthe DC Power Cabinet terminate the 48 volt DC wire on a DC OUTPUT distribution bus Return to Task List Connect Mixed AC DC Power and Ground Begin Return to Task List Typical Power and Ground for a Mixed AC DC Powered Cabinet shows a power and ground layout for a mixed AC DC powered cabinet configuration in the same equipment room with the PPN being DC powered and the EPN being AC powered If a second EPN is part of the system use the same basic connections Typical Power and Ground for a Mixed AC DC Powered Cabinet 40 1 AWG 44 mm up to 50 feet 15 2 m or engineered for less than 0 5 volt drop per conductor X To AC power source A Approved ground e Ground ac power cord discharge bar A 48V RTN AC power System distribution unit single point ground pe power PPN EPN supply cabinet cabinet gt To CBC terminal Cabinet block at MDF ground block Coupled A bonding conductor cydfacdc 032999 Return to Task List Connect Remote Power Off Cable Begin Return to Task List Remote Power Off Cable Connections Part 1 shows the locatio
168. Distance Dialing DDD network These circuit packs are intended for channels supporting voice therefore they support the following trunks CAS CO DID DIOD DMI FX Tie WATS They do not support any data trunk groups Note The P suffix designation means the circuit pack is programmable new firmware can be downloaded directly to the circuit pack For more information see Upgrade Firmware on Programmable Circuit Packs The TN464GP and TN2464BP circuit packs are backwards compatible although the echo cancellation feature can be used only with Release 1 1 or later of Avaya Communication Manager and after the feature is enabled The echo cancellation feature cancels echoes with delays up to 96 ms Echo cancellation is disabled automatically when the circuit pack detects a 2100 Hz phase reversed tone put out by high speed modems 56 kbaud but not when it detects a 2100 Hz straight tone generated by low speed modems 9 6 kbaud For information on installing port circuit packs see Add Port Circuit Packs For information on setting the option switches see Option Switch Settings Echo cancellation must first be purchased then added to the system via a new License File Administer TN464GP TN2464BP Begin Note You do not need to busyout the circuit packs to modify the settings But the modified settings do not take effect until either the port is busied out or the scheduled maintenance runs 1 Type display system parameter
169. EMORY FUNCTIONAL TEST MEMORY MODULE A STUCK BIT TEST MEMORY MODULE A PARITY TEST MEMORY MODULE A BURST TEST MEMORY MODULE B STUCK BIT TEST MEMORY MODULE B PARITY TEST MEMORY MODULE B BURST TEST MEMORY MODULE C STUCK BIT TEST MEMORY MODULE C PARITY TEST MEMORY MODULE C BURST TEST VIRTUAL MEMORY TEST EXCEPTION TEST TIMER TEST MTP TEST SANITY TIMER TEST ADDRESS MATCHER TEST FLASH DATA CHECKSUM TEST RAM DATA CHECKSUM TEST RESET 4 REBOOT PERFORMED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED PASSED Return to Task List Administer the System Return to Task List Note The following sections describe some of the procedures used to access and change certain options These sections are not intended to replace or modify the instructions provided in the Administrator s Guide for Avaya Communication Manager Task List Administer the System o N Oo A WO N Log in to the System Deliver or install the License File Administer no license emergency numbers Change Site Data 1 only Change Cabinet 1 MCC1 only Add Cabinet 2 through N AvayaDEFINITY Server Set Country Options Change the Password Set Daylight Savings Rules Set Date and Time 106 New Duplicated G3r installations only Log in to the System
170. Earthquake Protection for MCC1 Begin Return to Task List Use the correct procedure for your installation Install Concrete Floor Mounting Install Raised Computer Floor Mounting Install Concrete Floor Mounting 1 Position the cabinet in the exact position it is to occupy when the installation is complete 2 Insert a pencil or marker through the holes previously occupied by the carriage bolts front and rear in the bottom of the cabinet and mark the floor directly beneath each hole Roll the cabinet out of the way and drill four 1 2 in 1 27 cm diameter holes about 1 5 in 3 8 cm deep at the locations marked in Step 2 Insert concrete floor anchors STARR part number 3425 into the holes A Roll the cabinet back into place and align the cabinet holes over the concrete floor anchors Adjust the leveling legs until the cabinet is level See Earthquake Mounting Raised Computer Floor Note If the system is supplied with cable ductwork the cabinets must be level from front to rear and from side to side They must be square with respect to each other to within 1 8 in 0 3 cm 6 Secure the cabinet to the floor with the 4 supplied 3 8 16 x 4 5 in 11 4 cm bolts and four 3 8 in flat washers 7 Repeat this procedure for each cabinet to be installed 21 Install Raised Computer Floor Mounting 1 2 3 Position the cabinet in the exact position it is to occupy when the installation is comple
171. FI 1993 NOM SCFI 016 1993 NOM 019 SCFI 1998 The equipment described in this document may contain Class 1 LASER Device s These devices comply with the following standards EN 60825 1 Edition 1 1 1998 01 21 CFR 1040 10 and CFR 1040 11 The LASER devices operate within the following parameters Maximum power output 5 dBm to 8 dBm Center Wavelength 1310 nm to 1360 nm Luokan Laserlaite Klass 1 Laser Apparat Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposures Contact your Avaya representative for more laser product information Electromagnetic Compatibility Standards This product complies with and conforms to the following international EMC standards and all relevant national deviations Limits and Methods of Measurement of Radio Interference of Information Technology Equipment CISPR 22 1997 and EN55022 1998 Information Technology Equipment Immunity Characteristics Limits and Methods of Measurement CISPR 24 1997 and EN55024 1998 including Electrostatic Discharge ESD IEC 61000 4 2 Radiated Immunity IEC 61000 4 3 Electrical Fast Transient IEC 61000 4 4 Lightning Effects IEC 61000 4 5 Conducted Immunity IEC 61000 4 6 Mains Frequency Magnetic Field IEC 61000 4 8 Voltage Dips and Variations IEC 61000 4 11 Powerline Harmonics IEC 61000 3 2 Voltage Fluctuations and Flicker IEC 61000
172. FTP session for example denver ftppassword is any password that you choose for this FTP session for example broncos The password must be at least 7 characters long You use this same fftplogin and ftppassword in the section FTP the image file to source on page 345 This completes the preparation for a firmware download Upload image file from To upload files from the Web you need a temporary staging area to store the the Web to staging area firmware images before downloading them to a circuit pack Although the staging area is often on a PC platform you can also use other platforms such as a UNIX or Linux 1 Go to the Avaya Support Web site http avaya com support Follow the Software amp Firmware Downloads link and the subsequent links for your product and the target circuit pack TN code 2 Find the section for the firmware vintage you want Unless otherwise instructed choose the highest vintage 3 Be sure to read that vintage s ReadMe file before downloading the image file s 4 For each image file to be downloaded a Click on the image filename b Save this file to disk in a local staging area directory c Write down the path to the local staging area and the filename of the firmware image You need this information later FTP the image file to The following steps are generic to most FTP programs source 1 From the computer where the local staging area is bring up a DOS interface or UNIX Linux shell
173. GP TN2464BP and TN2313AP TN799C or TN799DP C LAN distributed UDS1 TN2214CP or TN2224CP TN799C or TN799DP C LAN distributed DIG LINE TN771DP Maintenance Test TN799C TN799DP C LAN distributed TN2302AP IP Media Processor TN799C or TN799DP C LAN distributed TN799DP C LAN TN799DP Self TN2501AP VAL TN2501AP Self 1 For TN2302AP circuit packs with a vintage less than 22 a different download procedure is required that is not described here Go to the Avaya Support Web site under Software amp Firmware Downloads DEFINITY ECS TN2302AP firmware downloads On the page titled Retired OLD Do Not Use DEFINITY Firmware Downloads scroll down to the TN2302AP section and click on TFTP Firmware download procedure pdf Make sure you have the following Superuser or services login and password to the Avaya Communication Manager PC or other server with the following IP connectivity to the source board Web browser Internet Explorer 5 0 or higher or Netscape 4 x IP connectivity to the World Wide Web e File transfer protocol FTP software program 343 Note Some GUI based FTP applications are incompatible with Avaya Communication Manager Command line FTP applications launched from a DOS prompt or UNIX shell work best If you need to distribute firmware from a source C LAN to target boards on a DS1 C DS1 converter complex remote port network then make sure a clear channel exists between t
174. INITY Upgrade Registration Report 18 Review the information displayed in the report If any of the data are incorrect contact the DBA Group 1 800 248 1234 selecting prompt 2 prompt 6 then prompt 2 immediately for assistance 19 Save the DEFINITY Upgrade Registration Report in a file for future reference or print the report and keep the copy Log off the System Begin Return to Task List Type logoff 123 The login prompt appears on the screen 124 Test the System This section provides tests to e review the status of the system test the tone clock TDM bus and duplication link in the Processor Port Network PPN e test the expansion interfaces tone clock s TDM buses and duplication in the Expansion Port Networks EPNs These tests verify the Time Division Multiplexing TDM cables terminators and the Inter Cabinet Cables ICC If a FAIL Result code is seen or other problems are indicated check these cables If problems persist refer to the Maintenance for Avaya DEFINITY Server documentation See LED Indicators for information regarding the LED status indicators for the different circuit packs Note Circuit pack positions are usually given by cabinet carrier and slot They may also be given by port The term cabinet refers either to a stack of SCC1 Single Carrier Cabinets or to an MCC1 Multi Carrier Cabinet making up one port network A port network is defined as a group of cabinets
175. ION Do not use the 329A power unit for the attendant console Use an 115141 1151A2 1145A or MSP 1 power unit 5 Forterminals needing adjunct power wire 48 VDC and ground to appropriate pins on the terminal See 302C1 to 4 wire DCP Wiring 302C1 to 4 wire DCP Wiring 9 9 TXT 1 lt lt lt __ gt __ 39 TXT5 TXR 2 gt gt 14 TXR5 PXT 3 amp 40 PXT5 PXR 6 gt gt 15 PXR5 Q lt 9 lt lt gt Q 302cwire RBP 040596 Figure Notes 1 302C1 Attendant Console 2 4 wire Digital Line Circuit Pack Position 1C02 3 48 VDC From Adjunct Power 4 Ground From Adjunct Power 142 Return to Task List Connect Adjunct Power Begin Return to Task List The 400B2 adapter is convenient for connecting local 48 VDC power to a modular plug See 400B2 Adapter Connecting to a Modular Plug Each port network can provide power for up to three attendant consoles This source of power is preferred for the attendant consoles because it has the same battery backup as the system See Auxiliary Connector Outputs Note Adjunct power can be provided locally at the telephone or console by either the 1151A1 or 1151A2 power supply Adjunct power can be provided from the equipment room or equipment closet with the 1145B power unit Go to Install and Wire Telephone Power Supply for power supply information and installation procedu
176. L LOOP2 24 SL W LOOP1 05 SL W LOOP1 All other pins empty 424 Index Index Numerics 100A LIU 387 10A LIU 388 110A type terminal blocks SCC 53 110P type terminal blocks MCC 54 110P type terminal blocks frame mounting 82 110RA1 12 terminating resistor block 204 110 type hardware 50 60 110 type hardware SCP 110 sneak current protection 56 110 type terminal blocks 53 110 type terminal blocks wall mounting 79 1110A2 apparatus mounting frame 82 1110C1 cable support 82 1145B power supply 183 186 188 1146B power distribution unit 189 193 1151A1 and 1151A2 power supply 196 197 1151A1 power supply 195 1151A2 power supply 195 120 CSU 280 127A BALUN coaxial adapter 305 315 258A adapter 63 26B 1 selector console 155 156 2 wire digital station wiring 143 3150 3170 CSU 282 356A adapter 63 367A adapter 206 3 pair and 4 pair modularity 151 3 pair modularity 76 3 pair to 4 pair station circuits 65 3 pair trunks cabling 58 4 port DIOD pinouts 417 440A4 terminating resistor adapter 204 451A extension adapter 63 4C3S 75 enhanced protector 165 4C3S 75 enhanced protector installing 166 4 pair station circuits 65 572 printer 371 7400A data module 338 369 7400A 7400B data module 101 102 7400B data module 338 7400B4 data module 102 7400D data module 366 808A emergency transfer panel 168 169 170 8400B data module 101 102
177. Location Enter the cabinet carrier and slot that identifies the physical location of the converter circuit pack connected to the second endpoint of the fiber link DS1CONV Board Type Display only field showing the type of 051 Converter circuit pack for the second endpoint This field is updated via the Change Circuit packs command Facility Installed Enter yes in the B C and D columns under the DS1 Converter Facilities heading to indicate that this DS1 facility is physically installed At least facility A must be installed within the converter complex Default is yes for Facility A Passes Far end Clock Enter yes in the B C and D columns under the DS1 Converter Facilities heading to indicate that this DS1 facility is suitable to be used as a clock source If the DS1 signal does not come directly from the far end 407 converter circuit pack or the network such as when the signal is converted from digital to analog and then back to digital enter no Default is yes for Facility A This field determines whether the DS1 converter circuit pack can use receive DS1 signal timing to time the transmit fiber signal This is necessary for passing timing from a master PN to a slave PN across a Converter Complex Digital Data Compatible Enter yes default in the B C and D columns under the DS1 Converter Facilities heading to indicate that this DS1 facility is suitable for transmission of digital data At least Facility A
178. Maintenance Name Alt Name Test No PN 01A TDM BUS 294 PN 01A TDM BUS 296 PN 01A TDM BUS 297 PN O1B TDM BUS 294 PN O1B TDM BUS 296 PN O1B TDM BUS 297 Command successfully completed MUN Result PASS PASS ABORT PASS ABORT PASS 5 Error Code 1005 1005 Return to Task List Test Tone Clock Boards Begin Return to Task List Testing the Tone Clock board also detects problems with the TDM bus cables 1 Type test tone clock 1a and press Enter 2 Verify page 1 displays the test results similar to Clock 1A Sample Test Results for Tone Clock 1A Sample Test Results for Tone fest tone clock la TEST RESULTS Port Maintenance Name Alt Name Test No Result Error Code 01 TONE BD 46 PASS 01A TONE BD 52 PASS O1AXXO1 ETR PT 42 PASS O1AXXO1 ETR PT 43 PASS O1AXX02 ETR PT 42 PASS O1AXX02 ETR PT 43 PASS O1AXX03 ETR PT 42 PASS O1AXX03 ETR PT 43 PASS O1AXXO04 ETR PT 42 PASS O1AXXO04 ETR PT 43 PASS O1AXXO05 ETR PT 42 PASS O1AXXO05 ETR PT 43 PASS O1AXXO06 ETR PT 42 PASS Nc O1AXXO06 ETR PT 43 PASS EN Return to Task List 132 Test SPE Duplication Memory Shadowing Link if duplicated Begin Return to Task List 1 Type test shadow link and press Enter 2 Verify the screen displays test results similar to Example Test Results for SPE Duplication Memory Shadowing Link Example Test Results for SPE Duplication Memory Shadowing Link 7 Port Maintenance Name Alt Name
179. N802B IP Interface faceplate of the TN802B IP Interface until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min it is safe to remove the circuit pack 6 After the TN802B is shut down unlatch and pull the circuit pack out about 2 in 5 cm then re insert it to restart the system TN802B IP Interface faceplate 2 9 fpdfmapd 030899 Figure Notes 1 LCD display 2 Reset button recessed 3 Red board status LED 4 PCMCIA card slot 5 Yellow PCMCIA disk in use LED 273 Return to Task List Upgrade IP trunks R7 to H 323 trunks Begin Return to Task List If there are existing IP trunk connections that you want to upgrade to H 323 trunk connections do the following steps Otherwise go to Upgrade to TN802B R10 To upgrade an existing IP trunk R7 to an H 323 trunk R10 requires first getting IP information from the existing TN802 before upgrading the TN802 to TN802B 1 Click on My Computer gt Control Panel gt Network 2 Click the Protocols tab 3 Select TCP IP Protocol from the list 4 Click the Properties option in the Network window Write down the IP address subnet address and gateway address shown for adaptor 2 For an example see TCP IP Properties Window IP Address Adapter 2 Note Do not use the addresses for adapter 1 5 When done click OK OK TCP IP Properties Wi
180. Note Not all networks require these steps Check with the local network administrator to determine which are required 1 If you use gateways type the IP address of the default gateway for the IP Interface server in the Default Gateway field 2 Onthe TCP IP Properties Window DNS click on the DNS tab and verify that the domain DNS server is correct 267 3 Type domain name in the Domain field 4 If using DNS click Add under the DNS Service Search Order field and type its IP address 5 On the TCP IP Properties Window WINS Address click on the WINS Address tab Note Make sure the 2 DEC shows in the Adapter field 6 If WINS server is available type its IP address in the Primary WINS Server field 7 If DNS is available select Enable DNS for Windows Resolution 8 If the network uses an imported LMHOSTS file select Enable LMHOSTS Lookup and Import LMHOSTS and click OK 9 If the following dialog box opens click Yes At least one of the adapter cards has an empty primary WINS address Do you want to continue 10 Click the Bindings tab to effect the changes NetBIOS Interface Server and Workstation should now be enabled If any are disabled a red circle with a line through it review the previous network configuration steps for omissions or errors 11 Click Close L WARNING When connected remotely via pcCANYWHERE use only the pcANYWHERE Restart Host Computer button on the toolbar to restart Window
181. Number LI High Side 47 LI 22 LO 48 LO High Side 23 LBACK2 49 LBACK1 24 to a connecting block on the trunk auxiliary field 148 Auxiliary Lead Appearances at AUX Connector shows the Control Carrier outputs cable pinouts The Control Carrier AUX connector outputs include Alarm monitoring for the auxiliary cabinet Seven 48 VDC power sources for emergency transfer units Three 48 VDC power sources for remotely powering three attendant consoles or telephone adjuncts The remote management terminal interface trunk connection location Arelay contact that actuates a customer supplied light bell or similar device The relay can activate when a major minor or warning condition occurs The device connected to the alarm leads must not exceed a rating of 30 VAC rms or 60 VDC at 0175 amps Auxiliary Lead Appearances at AUX Connector shows the pinouts for an external alarm Port Circuit Pack and Telephone Pin Designations provides port circuit pack and telephone pin designations Auxiliary Lead Appearances at AUX Connector Color Pinouts Output Power W BL 26 Major BL W 1 W O 27 Minor O W 2 W G 28 G W 3 GRD W BR 29 BR W 4 GRD W S 30 S W 5 GRD R BL 31 BL R 6 GRD R O 32 O R 7 GRD R G 33 Not Connected G R 8 R BR 34 Not Connected BR R 9 R S 35 Not Connected S R 10 149 Auxiliary Lead Appearances at AUX Connector Color Pinouts Output BK BL 36 48 BL BK 11 GND BK O 37 48 O BK 12 GND
182. ON OFF OFF Set REMOTE REMLOOP GRANT DENY GRANT LOOP Set RI LEAD RI CYCLE ON ON Set RL LEAD RL ON OFF OFF Set SIGLS DISC SIGLS DISC ON OFF ON Set TIMING TIMING INTERNAL EXTERNAL INT Set TM LEAD TM ON OFF OFF Note It is recommended that Cl and CH be set to ON and DCD and DSR be set to NORMAL This allows login information to be displayed on the screen without having to send a carriage return character Return to Task List Set DCS Switches Begin Return to Task List 1 Remove the top cover from the data module See DIP Switch Locations 2 Switches 1 5 and 8 are the only switches to be set Refer to Data Module Option Switch Settings for the option switch settings Note The options for the 7400A and 7400C Data Modules are set from the front panel interface For the 7400A refer to 7400A Data Module User s Manual For the 7400C refer to DEFINITY Communications System High Speed Link User s Guide DIP Switch Locations 367 METERING AA RD SD TR OH re POWER 9 d o No 1 2 3 4 5 6 7 8 Figure Notes 1 Data Module 7400A Shown 2 DIP Switch Data Module Option Switch Settings DIP Switch Function Setting 1 With Phone ON Without Phone OFF 5 Data Metering ON No Data Metering OFF 8 Make Busy on Loc Loop ON No Make Busy on Loc Loop OFF 2 3 4 6 and 7 OFF Return to Task List Set 7400D
183. Options Begin Return to Task List The following steps are an example of how to change the default setting of 9600 to the custom setting of 19200 Note If the link is between a R10r and a CMS set the 7400D to 19200 If the link is between any other system and a CMS leave the speed of the 7400D set at 9600 1 From the HOME screen press NEXT NO until SET OPTIONS is displayed Press ENTER YES to stay in the SET OPTIONS menu Press NEXT NO until SET 9600 SPEED is displayed Press ENTER YES when SET 9600 SPEED is displayed Press NEXT NO when 9600 ON is displayed Press ENTER YES when 9600 gt OFF is displayed o A WO N 368 7 8 9 10 11 12 13 Note The SET OPTIONS menu cannot be terminated if all soeeds are set to off Return to Task List Set 7400A and 7400B Options Press ENTER YES when CONTINUE is displayed Press ENTER YES when SET 19200 SPEED is displayed Press NEXT NO when 19200 OFF is displayed Press ENTER YES when 19200 gt ON is displayed Press NEXT NO when CONTINUE is displayed Press ENTER YES when 19200 gt ON is displayed Press ENTER YES when SAVE CHANGES is displayed Begin Return to Task List Determine if the 7400A or 7400B will be interfacing with D lead modems or attention control modems Use Options for D Lead and Attention Control Modems to interface with either modem You can set options for the 7400B through a dumb terminal Options fo
184. Output Power 1 o 1 i o Li T i Rien i B ip Norte ii z 1 8 F 1 1 o i T 0003 1 PDH 062596 Figure Notes 1 Wall Mounting Plate 2 Battery 1149B Shown 3 1146B Power Distribution Unit 4 1145B Power Unit 5 Power Cable 6 Unswitched Outlet 120 VAC 20 Amp or 230 VAC 15 Amp 7 Battery Backup Switch Setting Return to Task List Mount the 1146B Power Distribution Unit Begin Return to Task List See the 1146B Power Distribution Unit in Expanded Power Distribution Unit 1 Insert and securely tighten the two supplied 8 32 x 1 2 inch shoulder screws they have an unthreaded section at the top into the top holes designated for 1146B Power Distribution Unit on the bottom plate Mount the unit on these two shoulder screws using the key holes on the back of the unit 189 2 Secure the unit by inserting the 8 32 x 1 inch screw through the bottom of the unit just above the wire clips into the plate and tighten 3 Set the battery back up switch option to the 1 32 down position to provide battery back up to all outputs 4 Connect the power distribution unit to the power supply with the power cable Refer to the power supply s right hand label to locate the output power connection Expanded Power Distribution Unit 9 9 1149 Battery 9000000000000000
185. P solutions for customers including the Avaya R300 Remote Office Communicator For information on the Avaya R300 refer to the Avaya MultiVantage DEFINITY and S8100 Library CD The Avaya Media Gateway IP Media Processor allows you to send voice and fax from the Avaya Media Gateway through an Internet protocol IP network to other Avaya Media Gateways having this feature or to other H 323 V2 compliant endpoints It is implemented using either the TN802B IP Interface Assembly which is a Windows NT server residing on the IP Interface Assembly or the TN2302AP Media Processor Note The P board suffix designation means the circuit pack is programmable see Upgrade Firmware on Programmable Circuit Packs for more information Task List Implementing Avaya Media Gateway IP Solutions Avaya Media Gateways are implemented in these ways e Installing a TN2302AP IP Media Processor including Upgrading TN802 IP Trunking to TN2302AP IP Media Processor Upgrading a TN802B IP Interface Assembly to TN2302AP IP Media Processor e Installing a TN802B in Media Processor Mode Installing a TN802B in IP Trunk Mode Upgrading a TN802 V3 or later to a TN802B MedPro Mode TN802B IP Interface Assembly The IP Interface is an assembly composed of a TN802B circuit board a processor card and DSP resource card For ordering purposes the assembly is identified as a J58890MA 1 L30 but for simplicity we refer to it in this section as the TN802B IP Interface
186. PN and EPN cabinets Any of these power sources can supply 60 Hz power to the AC load in Release 5 and later systems Single phase 4 wire 120 240 VAC supplying 240 VAC This source has 2 hot wires 1 ground wire and 1 neutral wire J58890CE Single phase 4 wire 120 208 VAC supplying 208 VAC This source has 2 hot wires 1 ground wire and 1 neutral wire J58890CE Single phase 3 wire 208 or 240 VAC This source has 2 hot wires and 1 ground wire J58890CH Either of these power sources can supply 50 Hz power to the AC load in Release 5 and later systems Non United States 5 wire Y 220 380 VAC This source has 3 hot wires 1 neutral wire and 1 ground wire Non United States Delta 4 wire 220 or 240 VAC This source has 3 hot wires and 1 ground wire AC Power Sources and Plug Type describes the power sources and required AC input power 24 AC Power Sources and Plug Type Power Distribution Unit Power Sources Power Input AC power distribution Single phase 120 VAC with 120 VAC 60 Hz J58890CE 1 and neutral NEMA 5 50R 58890 2 Multi Carrier Singie phasa 240 VAC with 208 240 VAC 60 Gabinet neutral or single phase of 3 Hz NEMA L14 phase 208 VAC with neutral 30R AC power distribution Single phase 176 264 VAC 200 240 Volts 50 J58890CH 1 Multi Carrier 60 Hz NEMA L6 Cabinet 30R Installations outside the United States require a receptacle suitable for use in the country of in
187. PXT 4 PXR 4 5 TXT 5 TXR 5 PXT 5 PXR 5 6 TXT 6 TXR 6 PXT 6 PXR 6 7 TXT 7 TXR 7 PXT 7 PXR 7 8 TXT 8 TXR 8 PXT 8 PXR 8 Cross Connect Pin 421 Color W BL BL W W O O W W G G W W BR BR W W SL SL W R BL BL R R O O R R G G R R BR BR R R SL SL R BK BL BL BK BK O O BK BK G G BK BK BR BR BK BK SL SL BK Y BL BL Y Amphenol Pin 26 01 27 02 28 03 29 04 30 05 31 06 32 07 33 08 34 09 35 10 36 11 37 12 38 13 39 14 40 15 41 16 Backplane Pin 102 002 103 003 104 004 105 005 106 006 107 007 108 008 109 009 110 010 111 011 112 012 113 013 302 202 303 203 304 204 305 205 TN2198 ISDN BRI 2 wire U Interface Begin Port Signal e Color Amphenol Pin Backplane Pin in 1 T 1 1 W BL 26 102 R 1 2 BL W 01 002 2 T 2 3 W O 27 103 R 2 4 O W 02 003 3 T 3 5 W G 28 104 R 3 6 G W 03 004 4 T 4 7 W BR 29 105 R 4 8 BR W 04 005 5 T 5 9 W SL 30 106 R 5 10 SL W 05 006 6 T 6 11 R BL 31 107 R 6 12 BL R 06 007 7 T 7 13 R O 32 108 R 7 14 O R 07 008 8 T 8 15 R G 33 109 R 8 16 G R 08 009 9 T 9 17 R BR 34 110 R 9 18 BR R 09 010 10 T 10 19 R SL 35 111 R 10 20 SL R 10 011 11 T 11 21 BK BL 36 112 R 11 22 BL BK 11 012 12 T 12 23 BK O 37 113 R 12 24 O BK 12 013 Pins 25 and 50 are grounded by the backplane TN793B 24 Port Analog Line circuit pack Begin Port Signal Cross Connect Color AmphenolPin Backplane Pin Pin 1 T 1 1 W BL 26 102 R 1 2 BL W 01
188. R TLC5 Tip PBX Line Port 5 19 BR Y RLC5 Ring PBX Line Port 5 45 Y S TST5 Tip Emergency Terminal 5 20 S Y RST5 Ring Emergency Terminal 5 46 V BL COM1 Common 1 Relay Contact 21 BL V NO1 Normally Open 1 Contact 47 V O NC2 Normally Closed 2 Contact 22 O V NC1 Normally Closed 1 Contact 48 V G COM2 Common 2 Relay Contact 23 G V NO2 Normally Open 2 Contact 49 V BR 24 BR V 50 V S GRD Ground from Aux Cable 25 S V 48PX 48V from AUX Cable Connections for Telephone Used for Emergency Transfer 25 nje 2822 ES WIL 2 m TIT IT TC TK LC ST TC TK LC LC ST TC TK Lc ST LC ST 1M 1m 2M 2m 3M 8m 3w ALARM HONTOFS EM um ka s 1758580b MMR 042996 Figure Notes 1 To Network Interface Circuitry 2 To TN747 or Equivalent Central Office Trunk Circuit Pack 174 3 To Blue or White Station Distribution Field 4 To Power Transfer Unit 5 To Control Carrier Auxiliary Connector Connections for Telephone Used for Emergency Transfer and as Normal Extension 2 1 9 ST 2 o ELTIIIIIT E E mj s B E mmf 4 B 5 6 B H m 7 B E m 8 ITEN T 1 1M 1m 2M 2m 3M 3m 3w ALARM MONITORS EM TRANS RELAY PWR ACC PWR eee ee eee
189. RNING Electrostatic discharge can severely damage sensitive electronic circuits Before handling any electronic hardware be sure to wear a grounding wrist strap or other static dissipating device L WARNING Neglecting to shut down an AUDIX assembly before powering down the system cabinet where it resides can damage the AUDIX disk 1 Log into the AUDIX as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 2 Type reset system shutdown and press Enter 3 Press Enter again to start the shutdown The SHUTDOWN Completed message displays when the AUDIX is successfully shutdown This takes about 2 minutes 300 A CAUTION If leaving AUDIX System in the carrier back it out about 2 in 5 cm to eliminate the possibility of damage due to power surges Return to Task List Power Down System DS1 Tie and OPS Trunks Begin Return to Task List Note Power down the PPN only if the existing Tone Clock is being replaced in a standard reliability system 1 At the PPN set the main circuit breaker to OFF 2 Ateach EPN set the main circuit breaker to OFF Add Circuit Packs DS1 Tie and OPS Trunks Begin Return to Task List 1 Determine the port assignments of the circuit packs to be added 2 Install the TN722B DS1 Tie Trunk the TN767C 051 Interface or TN464C 051 Interface circuit pack in assigned carrier slot 3 Replace an existing TN756 Tone Detector Gener
190. Res de Roe iu E acci BEBE 405 Duplicated D 0510 Converter Complex Adminstaton iu TNS74 4 Circuit Packs 410 acks 411 stratic 411 DS1 undue E tot E1 TN1654 Circu t Pack 412 Duplicated DS1 Converter Complex Administration for E1 TN1654 Circuit pude 413 Connector and Cable Diagrams Pinout ap 415 417 419 421 TN7S 3B 24 Port Analog Line circuit pack TET E DS1 Interface Cable 00 307 424 Index 425 Installation for MCC1 Multicarrier Cabinets Made Easy Perform these tasks to install multicarrier cabinets 1 Oo ao F WO ND _ ok O 12 Install and Connect MCC1 Multicarrier Cabinet Install Telecommunications Cablin Bring the System Online Test the System Install and Wire Telephones Install and Administer Trunks Install and Wire Telephone Power Supply Install Additional Hardware Add IP Solutions Install and Connect Modems Administer the features telephones and other equipment according to customer data found on the provisioning plan Use the procedures in the Administrator s Guide for Avaya Communication Manager Test Telephones and Other Equipment Select the activity you are currently performing to see information task lists and procedures for that activity Note It may be more efficient to install each hardware component administer it and test it before going on to install an
191. Source and Target Source VAL TN2501AP Source and Target IP Media Processor TN2302AP Target DIG LINE 2 wire TN2214CP Target TN2224CP Target Maintenance Test TN771DP Target UDSI TN464GP Target TN2464BP Target TN2313AP Target 1 The TN799C C LAN circuit pack can be the source for a C LAN distributed download but cannot be the target circuit pack for either a self or C LAN distributed download because it is not a program mable circuit pack no P suffix 2 The TN799DP can be both source and target for a self download and can be the source for a C LAN distributed download 3 For TN2302AP circuit packs with a vintage less than 22 a different download procedure is required that is not described here Go to the Avaya Support Web site under Software amp Firmware Down loads DEFINITY ECS TN2302AP firmware downloads On the page titled Retired OLD Do Not Use DEFINITY Firmware Downloads scroll down to the TN2302AP section and click on TFTP Firmware download procedure pdf This section describes the procedures for either a self or C LAN distributed firmware download These procedures help you determine which method to use The main differences between the two methods are C LAN distributed The source circuit pack is always a C LAN either download TN799DP or TN799C Multiple target circuit packs of the same TN code can be scheduled for download at a time Self download The source and target circuit packs are
192. Speakerphone 71XXX series Analog voice 7101A 7102A 7103A 7104A 73XXX series Hybrid voice 7302H 7303H 7303S 7305S 7305H 74XXD series Digital voice 7401D 7403D 7404D 7405D 7406D 7407D 7410D 7434D 7444 69 81XX series Analog voice 8102 8110 91XX series 9101 9103 9110 84XX series Digital voice 8403B 8405B D B D 8410B D 8411B D 8412 8434 8435 94XX series 9403 9410 9434 Basic Rate Interface BRI 75XX series BRI voice 7505 VOM T 7506 VOM T 7507 VOM T 85XX series 8503 8510 8520 Workstation series Business Communications Data Terminals BCTs and Business Communications Systems BCS PC PBX platform digital PC ISDN platform BRI Consoles Data and voice 301A Attendant Console 302A1 Enhanced Generic 1 Console 602A1 ACD Console CallMaster digital communications terminal ZE01A Expansion Module for 8434Dx Voice and Features Cordless Hybrid Voice MDW 9000 TransTalk 9000 MDC 9000 DCP Data interface Data and voice Constellation Automatic Call Distribution ACD data terminal PassageWay interface Data and voice Consoles 302B1 302C1 Attendant Console 603A D Automatic Call Distribution ACD Console CallMaster digital console 603E Automatic Call Distribution ACD Console CallMaster digital console Connectable Administration Terminals These administration terminals can connect to the system Administration Terminal Application 715
193. T 2 PORT 1 BE E E E amp M E amp M E amp M E amp M SMPLX SMPLX SMPLX SMPLX 297 Tie Trunk Option Switch Settings and Administration Preferred Signaling E amp M SMPLX Prot Unprot Installation Situation Administered Format Switch Switch Port Circumstance System Far End Co Located DEFINITY E amp MType E amp MType E amp M Unprotected Type 1 1 1 Compatibl Standard Compatible Inter Building DEFINITY Protected Protected E amp M Protected Type 1 Type 1 Type 1 Compatibl Standard Compatible Plus Protection Unit Co Located Net E amp M Any PBX E amp M Unprotected Type 1 Integrated 1 Standard Return to Task List Add DS1 Tie and OPS Trunks Return to Task List The TN722B DS1 Tie Trunk TN767C or later DS1 Interface and TN464C or later DS1 Interface circuit packs provide connections to a 1 544 Mbps or 2 08 Mbps DS1 facility as 24 independent 64 kbps trunks Adding DS1 tie trunk service may require a service interruption notify the customer in advance as to when the addition will be carried out Task List Adding DS1 Tie and OPS Trunks Upgrading from a TN722 to a TN767C Disable Scheduled Maintenance and Alarm Origination to INADS DS1 Tie and OPS Trunks Save Translations DS1 Tie and OPS Trunks Shut Down DEFINITY LAN Gateway System DS1 Tie and OPS Trunks Shut Down DEFINITY AUDIX System DS1 Tie and OPS Trunks Power Down System DS1 Tie and OPS Trunks Add Circuit Packs DS1 Tie
194. TN2198 circuit pack 422 TN793B circuit pack 422 playback announcement testing 357 PNC duplication 404 PNC duplication administration fields 405 Poland country code 113 pooled modem adding 336 Port Assignment Record form 72 port circuit pack pin designations 144 151 159 port circuit packs installing 199 Port Network Connectivity See PNC positioning 317 power single phase 240VAC 24 power cabinet ground connecting approved DC ground 37 power cabinet grounds connecting DC 37 power distribution unit 157 194 power down AUDIX 95 power supply 193 1151A1 48V 195 1151A2 48V 195 power up AC powered system 105 AUDIX 95 DC powered system 105 powering AUDIX 91 PPN TDM testing 131 PPN cabinets cabinet location 19 PPN tests 125 PPN connect external modem 329 PRI trunks 294 295 296 primary protectors off premises connections 164 165 printer 572 option settings 371 option settings 371 processing element interchange testing 359 provisioning plan 49 Q queue warning indicator 179 queue warning indicator testing 357 R rebooting critical reliability systems 119 recorded announcement testing 357 rectifier module installing 33 registering system with INADS 121 remote access testing 358 remote network interface 159 160 remote PC connection to DEFINITY ECS 98 99 remote power off cable connecting 41 remote system access testing 358 removable media installing 104
195. TS changing network services 270 connecting components 249 259 ITW Linx enhanced protector 165 ITW Linx enhanced protector installing 166 J J58890CE 2 power distribution unit 31 Japan country code 113 jumper wires connecting trunk pairs 76 jumpers installing and administering 72 L labels fiber optic cable 390 labels control carrier cable 75 labels equipment room cabling 57 labels MDF 54 LAN testing external connection 255 LAN connections testing 271 large battery holdover 29 LASER Class 1 parameters 385 lead and color designations pinouts 419 lead designations port circuit packs and telephones 144 151 159 LED indicators Stratum 3 clock 361 LEDs alarms 125 attendant consoles 126 circuit packs 126 DS1 converter circuit packs 126 standby components 127 1 1 status 127 LEDs power distribution unit 194 License File 108 109 218 223 229 304 License Installation Tool LIT 109 218 223 229 304 light emitting diodes See LEDs lightguide connector panel 388 lightguide interconnect unit See LIU lightguide troughs 388 lightwave transceivers 385 LIU 385 LIU 100A 387 LIU 10A 388 locating the MDF 53 logging in to the system 107 M Macedonia country code 113 main circuit breaker 38 Main Distribution Frame See MDF MCC changing cabinet 1 110 changing cabinets 112 changing site data 110 earthquake protection 21 22 431 Index reboot
196. TY Server r Begin Return to Task List 1 Type add cabinet lt 2 44 gt and press Enter See Typical Add Cabinet Form 2 Fill in the blanks as required by the location and nature of the cabinet Typical Add Cabinet Form F Page 1 of 1 CABINET CABINET DESCRIPTION Cabinet 5 Cabinet Layout Cabinet Type expansion port network Number of Portnetworks 1 Survivable Remote EPN Survivable Remote Processor ID Room Floor Building CARRIER DESCRIPTION Carrier Carrier Type Number Duplicate Ne Return to Task List 112 Set Country Options Begin Return to Task List Certain country options need to be set to turn red failure indication LEDs off Refer to Country Codes for a list of country codes 1 Type change system parameters country options and press Enter A screen similar to Typical System Parameters Country Options Screen is displayed The cursor is set on the Companding Mode line 2 f the country uses A Law companding type A Law and press Enter The default companding mode is mu Law Other items eventually need to be entered on this screen but this is all that must be done to turn the red alarm LEDs off If all red LEDs do not go off reseat unplug and reinsert any port circuit packs displaying red LEDs A CAUTION To avoid a disk crash never reseat the DEFINITY AUDIX System without first shutting it down Shut down the DEFINITY AUDIX System and allow the disk to com
197. Test No Result Error Code TEST RESULTS SHDW LNK 318 PASS Command successfully completed X Return to Task List Test Duplicated Switch Processing Element Interchange if duplicated Begin Return to Task List 1 If Multi Carrier Cabinet MCC1 type status system cabinet number 1 44 and press Enter or If Single Carrier Cabinet SCC1 type status system all cabinets and press Enter Verify the screen displays test results similar to Example System Status Report for All Cabinets Note the MODE of SPE 1A and 1B Type refresh spe and press Enter N Command successfully completed displays Type reset system interchange and press Enter This causes the terminal to log off 6 Log in as craft again Note If you have a dadmin login and password you can use them instead of craft and the craft password 7 Note the MODE for SPE 1A and 1B should have changed from that noted in Step 3 Example System Status Report for All Cabinets Status cabinet 1 CABINET CONFIGURATION STATUS Carrier PN SN Carrier Location Number 018 PN 1 processor 01B PN 1 processor 01C PN 1 port 01D SN 1 dup sw node 01E SN 1 switch node CABINET EMERGENCY TRANSFER Emergency Select Transfer Switch 01B auto 018 auto Cabinet Tupe MCC SPE B CRBINET CONNECTIUITV STRTUS PN SN PN 1 SN 1 B PNC SN 1 R PNC CABINET ALARM PN SN PN 1 SN 1 SN 1 B PNC R PNC Connectivit
198. The 900 pair 110P type terminal blocks that can be used are e 110PE1 900CT FT 25 pair connector on the white field and field terminated on the blue field 110PE1 900FT Field terminated on both the white and blue fields Example of Extending 4 Pair Station Cables 63 crdfad1 CJL 101596 Figure Notes 1 Station Cable 2 Information Outlet 3 451A In Line Adapter 4 258A Adapter 5 4 Pair Station Cable 258A and BR2580A Adapters crdfadp CJL 101596 Figure Notes 1 BR2580A Adapter 2 258A Adapter 3 25 Pair Male Ribbon Connector 4 4 Pair Modular Jacks 8 Pins 356A Adapter crdf356 CJL 101296 Figure Notes 1 356A Adapter 2 4 Pair Modular Jacks 6 pins each connected to 25 pair ribbon connector Station Circuit Distribution from Equipment Room This section explains the station circuit distribution from the equipment room to the information outlets for new wiring installations Example connection diagrams are provided to show the options for running and connecting the station cables If most of the telephones voice terminals that require remote powering are within 250 ft 76 2 m of the equipment room 4 pair station circuits are run from the equipment room to the information outlets If this is not the case or if the customer requires 2 point administration 3 pair station circuits are run from the equipment room to satellite locations Then
199. Used globally Notes Tone detector tone clock with 4 TTR and 2 CPTR ports Used in combination with the TN748 in many countries initially in versions prior to G3V3 3 Used only with SCC ESCC cabinets with no EPNs no duplication no ASAI Use TN2182BV2 if CAMA feature is to be supported Tone clock only no TTR CPTR functionality Typically found with TN748 circuit packs in the U S Use TN744DV2 instead of TN748 with CAMA Tone clock only no TTR CPTR functionality Typically found with TN748 circuit packs in the U S Use TN744DV2 instead of TN748 with CAMA Tone clock plus 8 GPTR call classification ports Use TN2182B if CAMA feature is to be supported Begin Return to Task List 1 Insert the TN429C or later CO trunk circuit pack in any available port slot Be sure the TN744D Call Classifier Detector circuit pack is Vintage 2 or later 287 2 Wire the CAMA trunk to the MDF the trunk from the CO Refer to the pinouts in Circuit Pack and Auxiliary Equipment Leads Pinout Charts for 2 and 4 wire analog and digital lines 8 16 and 24 ports hybrid line MET line AUX and CO trunk or Circuit Pack and Auxiliary Equipment Leads Pinout Charts for 3 wire CO trunk DID DIOD trunk tie and DS1 tie trunk 2 and 4 wire ISDN BRI lines packet data line and 4 port DIOD Adding the Trunks Begin Return to Task List 1 Atthe prompt type add trunk next and press Enter 2 Onthe Trunk Group screen
200. WG Fe 48 V RTN bar at the MDF bar 7 cabinet Ground connection S ae e 48 V terminal s 7 2 single point 3 circuit ground 1 AWG 48 V RTN breaker Sea r gt 7 Be 7 EPN cabinet 2 DC battery OSV 75A e 48 V cabinet 8 48V LVD e Do fe 48 V RTN a X gt 7 EPN cabinet Frame ground TILAA 48 1 AWG DC power from rectifiers RTN 1AWG C Te 1AWG cabinet Single point ground Rectifiers block Main AC 6 AWG supply 6 AWG AC mains 6 AWG dc KLC 032999 Return to Task List Install Rectifier Modules and Battery Interface Unit Begin Return to Task List Each rectifier module operates as an integral part of a complete power system with battery backup The modules operate in a redundant high reliability mode to provide 48 VDC at 850 Watts to a common power bus The Battery Interface Unit BIU controls the rectifier modules manages the batteries and reports the status of system power The BIU provides the Remote Power Off RPO option and battery alarm interfaces for internal and external alarms 1 Install the BU3200A Battery Interface Unit in the first slot of the power distribution unit See Rectifier Module Installation Note The BIU and the rectifier modules are keyed and can only install 1 way 2 Install the first 2 RM0850HA100 Rectifier Modules into the second and third slots of the power distribution unit 3 If 2 to 3 carrier
201. _sup1 CJL 051496 Return to Task List 197 198 Install Additional Hardware This section provides information about and procedures for installing additional port circuit packs and other equipment to add more functionality to the DEFINITY ECS For procedures to install Avaya Media Gateways IP solutions see Add IP Solutions For procedures to install channel service units CSUs see Add Channel Service Units For procedures to install trunks see Install and Administer Trunks For procedures to upgrade firmware see Upgrade Firmware on Programmable Circuit Packs Avaya Media Gateways do not require an external modem because an internal modem is in the processor circuit pack For procedures to install modems see Install and Connect Modems Task List Installing Additional Port Circuit Packs WARNING Electrostatic discharge can severely damage sensitive electronic circuits Before handling any electronic hardware be sure to wear a grounding wrist strap or other static dissipating device If adding the packet bus support and TN570s must be installed as part of that support adding ISDN BRI requires a service interruption Notify the customer in advance as to when the addition will be carried out See Add Packet Bus Support for further information Select the information you need Add Port Circuit Packs Install and Administer ISDN BRI Add a TN2501AP Announcement Circuit Pack Add Multiple Announcement Add Speech Sy
202. a Metering OFF 8 Make Busy on Loc Loop ON No Make Busy on Loc Loop OFF 2 3 4 6 and 7 OFF Data Module DIP Switch Locations Figure Notes TA METERING AA RD SD TR OH Pn Fro POWER 9 DE LL TEST 7400B Data Module About 7400D Data Module Option Settings The option settings shown in 7400 Series Data Module Options Answer Only Interface are for the Answer Only interface and are set from the front panel interface Set only the desired speed of the 7400D All other default settings can be used 1 Data Module 7400A Shown 2 DIP Switch 7400 Series Data Module Options Answer Only Interface Set Option Display Set 300 SPEED Set 1200 SPEED Set 2400 SPEED Set 4800 SPEED Set 9600 SPEED Abbreviation Possible Values Default 300 ON OFF ON 1200 ON OFF ON 2400 ON OFF ON 4800 ON OFF ON 9600 ON OFF ON 366 7400 Series Data Module Options Answer Only Interface Set Option Abbreviation Possible Values Default Display Set 19200 19200 ON OFF ON SPEED Set ANSWER ANS AUTO MANUAL AUTO Set Cl LEAD Cl ON OFF OFF See Note Set CH LEAD CH ON OFF OFF See Note Set CTS LEAD CTS NORMAL ON ON Set DCD LEAD DCD NORMAL ON ON See Note Set DSR LEAD DSR NORMAL ON ON See Note Set DTR DTR 0 10 20 30 50 100 50 DETECT MSEC Set DTR LEAD DTR EIA STANDARD EIA IGNORE STANDARD Set LL LEAD LL
203. abinet connect 1 end of the connector cable to the assigned connector Route the cable down the rear of the cabinet through the cable slack manager and to the MDF At the MDF connect the other end of the cable to the assigned terminal connecting block connector Store the cable slack in the cable slack manager Repeat Steps 2 through 6 until all cables are installed Return to Task List 78 Install Connector Cables Between Auxiliary Cabinet and MDF Begin Return to Task List Auxiliary equipment that connects to the MDF can be mounted inside the Auxiliary cabinet The equipment connects to an ED 1E1443 10 Group 1 intraconnection panel mounted in the cabinet This intraconnection panel consists of a 110 type 100 pair wiring block Auxiliary equipment is connected to the 110 type wiring block The wiring block is pre wired to four 25 pair female connectors mounted on the outside rear of the cabinet 1 Install D rings on the wall between the cable slack manager and the terminal connecting blocks mounted on the MDF 2 Install a self sticking port label on the rear of each connector on the B25A connector cable See Self Stick Label on 25 Pair Cable Connector 3 Labels should be positioned so they will not be obscured by the cabinet connector retainers 4 At the rear of the Auxiliary cabinet connect 1 end of the connector cable to the assigned connector 5 Route the cable down the rear of the cabinet and through the c
204. able attendant console cabling distances 154 cables 25 pair I O 61 84 DCS 225 fiber optic 44 installing 209 IP interface 258 IP Media Processor 242 245 outputs for control carrier 148 cables installing 56 236 249 cables installing between auxiliary cabinet and MDF 79 cables installing between cabinet and MDF 78 cabling installing trunk cables 58 provisioning plan 49 cabling labels 57 cabling layout 71 call detail recording See CDR calling queue 179 CallVisor ASAI adding 216 CallVisor ASAI installing 217 218 219 CAMA E911 trunks 285 287 288 289 290 291 292 carbon block protectors off premises connections 164 CDR option settings 374 printer 371 CE marks 4 Cellular Business System 200 channel service unit See CSU check commercial power 43 checking circuit pack configuration 131 137 checking system status 129 China country code 113 circuit pack configuration testing 131 137 circuit pack damage or discrepancies 19 circuit pack LEDs 125 circuit pack pinouts 415 417 circuit packs adding 200 classification 200 configuration testing 137 digital line 98 DS1 converter LEDs 126 duplication interface LEDs 126 installing 202 LEDs 126 pin designations 415 Circuit Packs form administration commands 93 circuit pack cabinet layouts 93 implementation notes 94 instructions 03 circuit packs administering 92 C LAN 224 238 240 253 test external connection to LAN
205. able male to male between the equipment room and satellite closet Use a B25A cable between the equipment room and site closet or adapter Multiple 25 pair station cable Use between the equipment room and site satellite locations or adapters This cable consists of individually sheathed 25 pair cables with a factory installed 25 pair connector on each end Use a male to female cable to connect between the equipment room and site location or adapter Use a male to male cable to connect between the equipment room and satellite location Staggered finger cables are recommended for all multiple 25 pair station cables and are available in both double ended and single ended types Single modular plug ended 4 pair station cable Use this cable between adapters and information outlets that require push on connections It can also be used when 4 pair station cables are field terminated on the 110 type terminal blocks in the equipment room or satellite closet and modularly connected to information outlets The station cables are available in the following lengths 10 ft 3 05 m 25 ft 7 62 m 50 ft 15 24 m 75 ft 22 86 m 100 ft 30 5 m 150 ft 45 72 m 200 ft 61 Note If more than 200 ft 61 m of 4 pair station cable is required a 451A in line adapter double ended modular female connector is attached to the cable and a second 4 pair cable of the required length is plugged into the adapter See Example of Ex
206. able slack manager to the MDF 6 Atthe MDF connect the other end of the cable to the assigned terminal connecting block connector 7 Store the excess cable in the cable slack manager 8 Repeat Steps 2 through 6 until all cables are installed Self Stick Label on 25 Pair Cable Connector He M O Ibdf25p LJK 101596 Return to Task List Mount 110A or 110P type terminal blocks on the wall Begin Return to Task List The 110A type terminal blocks can be stacked in almost any arrangement at any height or location on the wall One arrangement is shown in 110A Type Terminal Blocks 300 Pair The distance between the mounting screw holes on the terminal blocks is 10 8 in 27 4 cm If a vertical patch cord trough is used the distance between the mounting screw holes is 5 31 in 13 3 cm With 110P type terminal blocks the first block of the trunk auxiliary field is aligned with the left side of the system cabinet See 110P Type Terminal Blocks 900 Pair This arrangement allows for growth on the right side of the MDF 1 Route the cables from the rear of the cabinet stack to the MDF via the Cable Slack Manager See Install Cable Slack Managers 79 N A Oo oF 10 11 12 13 If you are installing 300 pair terminal blocks draw a level horizontal line on the wall 47 5 in 1 2 m above the floor See 110A Type Terminal Blocks 300 Pair If you are installing 900 pair terminal blocks dra
207. acks for general information Reboot High Reliability System MCC1 only Enable Duplication and Boot Critical Reliability System Avaya DEFINITY Server r Administer Attendant Console Save Translations Avaya DEFINITY Server si or Save Translations Avaya DEFINITY Server r Administering Fiber Optic Cables Add Translations Avaya DEFINITY Server si or Add Translations Avaya DEFINITY Server r Resolve Alarms Register the Switch for Maintenance Log off the System About Accessing the System To administer the Avaya Media Gateway you must be able to access the system The Avaya Media Gateway no longer requires a dedicated management terminal known as a system administration terminal or SAT Personal computers and technician laptops equipped with Avaya Site Administration software are the primary support access for system initialization aftermarket additions and ongoing maintenance SAT is now an option 91 Administration Screens and Commands The system is administered using screens displayed on the PC The screens are used to add change display list data and to remove system and telephone features To access a screen enter a valid system command in response to the command prompt System commands are standard words and phrases instructing the system to perform a specific function The commands are arranged in a hierarchy of keywords that is enter one command to go to a different level The commands contain three
208. al transmitRRing B Return to Task List Three Pair and Four Pair Modularity Return to Task List 3 Pair and 4 Pair Modularity is from the port circuit pack to the voice or data terminal Refer to Install Telecommunications Cabling for descriptions of 3 and 4 pair modularity and distribution Most terminals connect to an information outlet modular jack installed at the work location Make the connections from the port circuit pack to the modular jacks as shown in 3 Pair and 4 Pair Modularity Then plug the terminal into the modular jack Adjunct Power Connection Locations shows three methods of connecting adjunct power 3 Pair and 4 Pair Modularity 151 26 1 UP me 1 1 1 1 2 2 T4 2 2 XU Y 27 3 3 9 MS qe 2 4 4 4 4 28 5 i d 5 5 l 1 3 6 6 6 1 1 7 7j 7 widf3pm PDH 011397 Figure Notes 1 Port Circuit Pack 2 System Cabinet Connector Pins 3 Pair Modularity 3 Main Distribution Frame MDF Pins 3 Pair Modularity 4 Input to Information Outlet 4 Pair Modularity 5 Adjunct Power 6 Output From Information Outlet 4 Pair Modularity 7 Voice or Data Terminal Pins Return to Task List Adjunct Power Connection Locations Return to Task List Example Adjunct Power Connections shows typical connection locations for adjunct power Adjunct power for station equipment may be suppl
209. amage before opening it If the box is damaged do not open it Inform the shipping company and ask for instructions on filing a claim 2 If the box is undamaged check the contents against the packing slip Check the condition of each component and note any damage or shortages on the packing slip See Required Hardware for what the carton should contain for each IP Interface ordered 3 Read and follow any directions inserted into the package by the factory The TN802B external cable assembly is a bundle of cables with an amphenol connector at the end of the bundle and various PC type connectors VGA Universal Serial Bus USB mouse keyboard Ethernet modem and COMO at the ends of the individual cables See TN802B IP Interface External Cable Assembly Look for the label where the bundle enters the amphenol connector Required Hardware Description Quantity TN799x C LAN circuit pack 1 TN802B IP Interface Assembly 1 or more H600 512 G1 external cable assembly 1 or more 259A connector 1 257 Required Hardware Description Quantity CAT5 or better cable 1 U S Robotics Sportster external modem Model 1 USR 33 6 EXT U S customers only Non U S customers must provide a modem comparable to this model 20 ft DB 25 serial cable from modem to TN802B 1 external cable assembly U S customers only Non U S customers must provide a serial cable 1 One TN799x supports more than one TN802B TN802B IP Interface External Cab
210. ance and press Enter 5 Enter the ten digit product identification Enter the INADS OSS telephone number in the First OSS Telephone Number field 6 Enter first only in the Alarm Origination to OSS Numbers field and press Enter to enable Alarm Origination to the first OSS 7 Ifthey are needed enable Cleared Alarm Notification and Restart Notification Note Avaya Media Gateway supports up to two OSS telephone numbers Some services contracts may require the second OSS telephone numbers and a different option in the Alarm Origination to OSS Numbers field to be administered Connections at Trunk Auxiliary Field 1758482b RBP 062696 Figure Notes 1 To Network Interface Facility 2 To Control Carrier Auxiliary Connector 3 One Pair of Wires 4 Twenty fifth Pair of RJ21X Network Interface Jack Return to Task List Install Off Premises Station Wiring Begin Return to Task List The local telephone company provides cabling outside the building for off premises stations The off premises stations can appear on any of the RJ21X network interfaces provided for the Central Office CO trunks A CAUTION Only an FCC approved or equivalent analog type telephone such as a 2500 type can be used as an off premises station The TN746B and TN2183 Analog Line circuit packs can be connected to off premises stations 1 Install an A25D male to male cable between the RJ21X network interface and a sneak fuse panel 1
211. and Auxiliary Equipment Leads Pinout Charts Begin Con Analog Digital nector Line Line amp Pin Nos 8 Analog Line 16 2 wire 26 T1 T1 01 R1 R1 27 T2 02 R2 28 T3 03 R3 29 T2 T4 04 R2 R4 30 05 31 06 32 T3 07 R3 33 08 34 T5 09 R5 35 T4 T6 Data Line amp Digital Line 4 wire TXT1 TXR1 PXT1 PXR1 TXT2 TXR2 PXT2 PXR2 TXT3 TXR3 PXT3 PXR3 415 Digital Line amp Analog Line 24 2 wire T1 R1 T2 R2 T3 R3 T4 R4 T5 R5 T6 R6 T7 R7 T8 R8 T9 R9 T10 Hybrid Line V1T1 V1R1 CT1 CR1 P 1 1 V1T2 V1R2 CT2 CR2 P 2 P 2 V1T3 V1R3 CT3 CR3 P 3 P 3 V1T4 AUX Trunk T1 R1 SZ1 SZ11 S1 511 T2 R2 SZ2 5412 52 512 T3 R3 SZ3 5413 53 513 T4 co Trunk T1 R1 T2 R2 T3 R3 T4 Color S R BK BL BL BK BK O O BK BK G G BK BK B BR B BK S S BK Y BL BL Y Con nector Pin Nos 10 36 37 12 38 13 39 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 Analog Digital Line 8 R4 T5 R5 T6 R6 T7 R7 T8 R8 Line amp Analog Line 16 2 wire R6 T7 R7 T8 R8 T9 R9 T10 R10 T11 R11 T12 R12 T13 R13 T14 R14 T15 R15 T16 R16 Data Line amp Digital Line 4 wire TXT4 TXR4 PXT4 PXR4 TXT5 TXR5 PXT5 PXR5 TXT6 TXR6 PXT6 PXR6 TXT7 TXR7 PXT7 PXR7 TXT8 TXR8 PXT8 PXR8 Digital Line amp Ana
212. and OPS Trunks Power Up System DS1 Tie and OPS Trunks Enter Added Translations DS1 Tie and OPS Trunks Save Translations DS1 Tie and OPS Trunks Resolve Alarms DS1 Tie and OPS Trunks Deliver or Install License file DS1 Tie and OPS Trunks o ON Oo 25 11 12 298 13 Adding TTC Japanese 2 Mbit Trunks Return to Task List Upgrading from a TN722 to a TN767C Begin Return to Task List 1 Remove all TN722 trunk members from affected trunk groups 2 Type remove ds1 UUCSS the slot containing the TN722 3 Remove the TN722 circuit pack 4 Put the TN767C circuit pack into the same slot 5 Wait until the red LED goes off The hardware tests take 12 to 20 seconds to run When the red LED goes off the tests have completed 6 If the red LED stays on reseat the board and repeat this step 7 Type add ds1 PCSS 8 Continue with appropriate procedures to set up members of trunk groups Return to Task List Disable Scheduled Maintenance and Alarm Origination to INADS DS1 Tie and OPS Trunks Begin Return to Task List 1 To prevent scheduled daily maintenance from interfering with the update or upgrade type change system parameters maintenance and press Enter 2 f scheduled maintenance has begun set the Stop Time field to 1 minute after the current time has not begun set the Start Time field to at least 8 hours after the upgrade starts A CAUTION If you do not disable Alarm Origination the system may
213. and of the modem and is not case sensitive Most modems provide a timer that abandons any outbound data call after a predetermined interval This is a non administrable parameter Return to Task List Add U S Robotics Model USR 33 6 EXT External Modem to EPN Begin Return to Task List 1 Connect an RS 232 cable to the modem See Connect External Modem to EPN Note In the following steps a PC with Windows 95 or Windows NT 4 0 may be substituted for the dumb terminal Use the Hyperterminal terminal emulation application 2 Connect the opposite end of the RS 232 cable to a dumb terminal 3 Set the dumb terminal to full duplex mode 4 Type AT amp NG to set the baud rate to 9600 The modem connects at 9600 baud but throughput is at 1200 baud 5 Type AT amp WO to save the setting into non volatile RAM 6 Set Switch 5 to the OFF up position to disable auto answer 7 Disconnect the RS 232 cable from the terminal and connect it to the TERMINAL connector on the rear of the system cabinet Connect External Modem to EPN 328 cydfepnm KLC 100397 Figure Notes 1 U S Robotics External Modem 2 RS 232 Cable 3 Expansion Port Network Return to Task List Add U S Robotics Model USR 33 6 EXT External Modem to PPN Begin Return to Task List 1 Connect an RS 232 cable to the modem See Connect External Modem to PPN Note In the foll
214. ant is maintained between 42 5 and 54 2 volts DC at all times for proper operation and to prevent hardware damage The wire must be sized for a maximum voltage drop of 0 5 VDC in each leg of the DC distribution This procedure applies to both PPN and EPN cabinets Task List Connect DC Power and Ground Perform these tasks to connect DC power and ground power distribution unit J58890CH 1 Only 1 2 Install Rectifier Modules and Battery Interface Unit Connect Power and Ground s Perform these tasks to connect DC Power and Ground J58890CF Only Note These installation tasks correspond to the numbers in Typical Power and Ground for a DC Powered Cabinet 1 on O OC A WO M 9 Install Coupled Bonding Conductor Wires Connect DC Battery and Power Cabinet Grounds Connect DC Power Cabinet Approved Ground Connect AC Power to DC Power Cabinet Connect Ground Wires for DC Powered Systems Turn Circuit Breakers Off Connect DC Power to PPN and EPN Cabinets Connect DC Battery Cabinet to DC Power Cabinet If necessary Connect Mixed AC DC Power and Ground Typical Power and Ground for a DC Powered Cabinet 32 1 AWG ground wire Approved DC power cabinet ground eee To 4 10 AWG 7 Ground CBC ground terminal discharge 1 A
215. application at your laptop PC 3 Use the LIT instructions to add a switch connection profile to the tool 4 Use the LIT instructions to install the License File on the switch 5 f the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints A CAUTION Return to Task List Adding TTC Japanese 2 Mbit Trunks Begin Return to Task List The TN2242 Japan 2 Mbit trunk interconnects the switch with other vendor equipment in Japan as well as to interconnect other switches through the Time Division Multiplexor device 1 Determine the port assignment of the trunk from the Trunk Group screen 2 Install a TN2242 circuit pack in assigned carrier slot 304 3 Connect the H600 513 cable from the cabinet to the Time Division Multiplexor device 4 To administer forms see the following sections in the Administrator s Guide for Avaya Communication Manager For ISDN applications see the ISDN Service section For non ISDN applications see the Managing Trunks section Return to Task List Add TN1654 DS1 Converter r only Return to Task List The TN1654 DS1 converter circuit pack supports from 1 to 4 T1 24 channel or E1 32 channel facilities For more information on this DS1 converter see Circuit Pack Switches Circuit Pack and Cabling T1 Only e 75 ohm E1 Interface Cabling Task List Adding a TN1654 DS1 Conve
216. artial number of 0 5 or more should be rounded up for example 2 4 2 Cable Slack Managers and 2 5 3 Cable Slack Managers Note Cable clamps are required in installations with Cable Slack Managers At the rear of the cabinets on each rear ground plate install two cable clamps using the screws provided These clamps hold the 25 pair input output or Main Distribution Frame MDF cables in place Station Wiring Design Information Outlets The following hardware and cabling is used e Information Outlets modular wall jacks e Station Cables e Closets Site locations Satellite locations A brief description of each of the above listed items follows Ordering information is not provided for station cables and information outlets Information outlets are 8 pin modular wall jacks Most of the outlets are wired with push on connections Information outlets are also available that connect to a double 61 Station Cables modular plug ended 4 pair station cable routed from the MDF a site satellite location or an adapter For clarity a station cable is either a 25 pair cable multiple 25 pair cable or 4 pair D inside wire DIW run from the equipment room site satellite location or adapter to the information outlets The following station cables are available See Example of Extending 4 Pair Station Cables 25 pair station cable Use between the equipment room and site satellite locations or adapters Use an A25D c
217. asions to humans Mischief troubling but apparently innocuous tampering Harm such as harmful tampering data loss or alteration regardless of motive or intent Be aware that there may be a risk of unauthorized intrusions associated with your system and or its networked equipment Also realize that if such an intrusion should occur it could result in a variety of losses to your company including but not limited to human data privacy intellectual property material assets financial resources labor costs and or legal costs Responsibility for Your Company s Telecommunications Security The final responsibility for securing both this system and its networked equipment rests with you Avaya s customer system administrator your telecommunications peers and your managers Base the fulfillment of your responsibility on acquired knowledge and resources from a variety of sources including but not limited to Installation documents System administration documents Security documents Hardware software based security tools Shared information between you and your peers Telecommunications security experts To prevent intrusions to your telecommunications equipment you and your peers should carefully program and configure Your Avaya provided telecommunications systems and their interfaces Your Avaya provided software applications as well as their underlying hardware software platforms and interfaces Any other
218. assword in the indicated fields Note ART user IDs and passwords are unique to ART and are not the same as other user IDs and passwords If you are a first time user and do not have an ART user ID and password a Go back to the ART User Menu and click on the Administer My User ID Password button b Follow the instructions on the User ID and Password page to create your ART user ID and password 121 Unless you exit and restart your browser you do not need to re enter your user ID and password to perform other ART operations The ART Start of Product Registration page appears and the ART session ID appears in the middle of the screen 4 Type the Installation Location or Sold To data in the FL Sold To Number field Note Sold To number replaces the FL numbers as customer site identifiers in the Maestro database Sold To numbers are typically 7 digits long sometimes beginning with an upper case S followed by two zeros for example 8001234567 FL numbers are 10 12 letters or digits 5 In the Session Type field select NEW INSTALL REGISTRATION for products that are initially installed at a customer site UPGRADE REGISTRATION for all subsequent product registrations 6 In the Product Type field choose DEFINITY for the following products 7 Click on the Start Product Registration button 8 If the data you have entered matches a Maestro database record the Customer Verification page appears 9 Verify the information in
219. ator circuit pack with TN768 TN780 or a non United States TN419B Tone Clock TN748B or a non United States TN420B Tone Detector TN2182 Tone Clock Install Cables DS1 Tie and OPS Trunks Begin Return to Task List Install H600 307 cable from the cabinet to a Channel Service Unit CSU and install cables from the CSU to the MDF as required Power Up System DS1 Tie and OPS Trunks Begin Return to Task List 1 At each EPN set the main circuit breaker to ON 2 Atthe PPN set the main circuit breaker to ON 3 The system performs the level 4 rebooting process loading the system translations from the translation card or removable media Rebooting takes 8 to 11 minutes 301 4 After the system reboot is finished and all trouble is cleared verify that the EMERGENCY TRANSFER CONTROL switch is set to AUTO This restores the system to the normal mode Return to Task List Enter Added Translations DS1 Tie and OPS Trunks Begin Return to Task List Administer forms listed under 051 Tie Trunk Service in Administrator s Guide for Avaya Communication Manager Save Translations DS1 Tie and OPS Trunks Begin Return to Task List 1 If the system is high or critical reliability status system 1 and press Enter to verify that the system is in the active standby mode 2 Type save translation and press Enter This instructs the system to take all translation information in memory and write it
220. ay power and attendant console power This field is used for emergency transfer wiring paging equipment music sources and so forth The distribution field contains four cross connect areas The purple field port field terminates 25 pair cables from the system Each line circuit pack connects to one 25 pair row of the 110 type terminal block One 25 pair cable is required for each line circuit pack 52 Note The 16 port analog line circuit pack requires an adapter cable to connect from one connector on the system to two 25 pair connectors on a terminal block Two MET circuit packs require a concentrator cable to connect from two connectors on the system to one 25 pair connector on a terminal block yellow field auxiliary field terminates all 25 pair cables from the auxiliary cabinet and the Processor Interface The yellow field is located in the lower right hand corner of the distribution field The white field station field terminates the station wiring The white field indicates 3 pair station circuits eight circuits per 25 pair cable routed through a satellite closet blue field station field also terminates station wiring The blue field indicates 3 and or 4 pair station circuits eight or six circuits respectively per 25 pair cable The fourth pair of the 4 pair station circuit provides adjunct power from the cross connect field on an as needed basis to terminals within 250 feet 76 m o
221. ber Link 1 ENDPOINT 1 A PNC Board Location 01E01 Board Type ei DS1CONV Board Location 01B01 DS1CONV Board Type TN574 ENDPOINT 1 B PNC Board Location 01001 Board Type ei DS1CONV Board Location 01C01 dd Board Type TN574 Page 1 of 3 FIBER LINK ADMINISTRATION Is one endpoint remoted via DS1 Converter Complex yes ENDPOINT 2 A PNC Board Location 02A01 Board Type ei DS1CONV Board Location 02B01 DS1CONV Board Type TN574 ENDPOINT 2 B PNC Board Location 02A02 Board Type ei DS1CONV Board Location 02C01 DS1CONV Board Type TN574 Return to Task List DS1C Converter Complex Administration for TN574 Circuit Packs Return to Task List Fiber Link Administration form for TN574 Circuit Pack DS1 Converter Complex Administration page 2 of 3 shows the fields available to administer the TN574 circuit pack The following DS1 Converter Complex fields appear on Page 2 when the Is one endpoint remoted via a DS1 Converter Complex field is y Note When you administer DS1 Converter TN1654 circuit packs different fields display DS1CONV Board Location Enter the cabinet carrier and slot that identifies the physical location of the converter circuit pack connected to the first endpoint of the fiber link This is entered on Page 1 and displays on Page 2 DS1CONV Board Type Display only field showing the type of 051 Converter circuit pack for the first endpoint DS1CONV Board
222. ble when an adapter cable is used Note The older version of 715 BCT the 715 Business Communications System BCS 406803148 and 406803155 has a 6 pin mini DIN keyboard connector 141 The new version of 715 BCT the 715 BCS 4073113881 and 407313899 has a 6 pin RJ 11 keyboard jack located on the side of the terminal Connect a Typical Telephone Begin Return to Task List The 302C1 Attendant Console is used to describe a typical telephone connection This information is typical of the 603E 84xx 4 wire and 94xx telephones The attendant console always requires auxiliary adjunct power 48 VDC Power is connected to the console through Pins 7 and 8 of the information outlet Only three consoles can be powered by the system through the AUX connector When possible the primary console should be powered from the system so it has the same power failure backup as the system The maximum cabling distance for the console powered from the cabinet is 350 feet 100 meters The general steps to connect a telephone are 1 Choose a device to connect such as a 302C1 Attendant Console 2 Choose the port circuit pack and its carrier and slot number such as cabinet 1 carrier C slot 02 3 Choose a port circuit on the port circuit pack such as Port 05 4 Install cross connect jumpers to wire the terminal to the port circuit pack See 302C1 to 4 wire DCP Wiring This pinout is for the 4 wire Digital Line circuit pack A CAUT
223. board LAN Connections Begin Return to Task List To test the onboard LAN connections ping the IP Interface server and the processor on the TN802B IP Interface 1 Click Start gt Programs gt Command Prompt 2 Type ping 192 11 13 9 which is the IP address of the internal IP Interface server 271 If everything is configured correctly the system responds with the following message Reply from 192 11 13 9 bytes 32 time lt ms TTL If no response verify the IP address information and check the connectivity including the cabling 3 Atthe command prompt type ping 192 11 13 8 which is the IP address of the internal processor If you have connectivity the system responds with the following message Reply from 192 11 13 8 bytes 32 time lt ms TTL If no response verify the IP settings for Adapter 1 4 Type exit and press Enter The TN802B IP Interface is now installed in the DEFINITY carrier and connected to the IP network You can now use the Configuration Manager software preinstalled on the TN802B hard disk and Avaya Media Gateway switch administration to administer connections to other IP Trunk and ITS E equipment Return to Task List Upgrading a TN802 V3 or later to a TN802B MedPro Mode Return to Task List This section includes general information on adding the TN802 TN802B in MedPro mode and the Task list Upgrade a TN802 to a TN802B If you have a TN802 V3 or later IP Interface
224. cables containing 3 pair circuits multiply the number of 3 pair circuits required at the satellite location by 3 5 Then using the minimum size cable requirement round up the cable size requirement to the next highest available cable bundle size This will provide additional pairs for growth and compensate for every twenty fifth pair in a cable that is not used 4 Pair Station Cable Circuits To determine the size of station cables containing 4 pair circuits find out how many information outlets are served by the equipment room MDF or satellite location MDF Multiply the number of information outlets by 4 Then using the minimum size cable requirement round up the cable size requirement to the next highest available cable bundle size Note This formula may not compensate for the unused twenty fifth pair in all cases If not it must be allowed for Patch Cord Jumper Installation and Administration Before starting the patch cord installation obtain a copy of the Port Assignment Record forms from the customer or marketing representative See Port Assignment Record Form These forms contain the port assignments and identify the extension numbers Terminal No of the telephones voice terminals Enter the jack assignments at the equipment room and indicate if adjunct power is required and where it is provided MDF site satellite closet or information outlet When satellite locations are provided enter the satellite letter designation
225. citors The bottom row is designated as the input row and the top and middle rows are designated as the output rows The circuit assembly is mounted on a standard 1104 100 pair mounting base The 110RA1 12 is shipped with preprinted designation strips to simplify circuit identification and installation Typical Installation of Terminating Resistor Block Using Multipoint Connection shows the wiring connections for the 110RA1 12 terminal block The TN556 BRI switch port is terminated to bottom row C For point to point wiring the top row is connected to the blue station field The pair connects from the 110RA1 12 to the standard 4 pair circuit Pair 1 from the 110RA1 12 is connected to Pair 1 of the station field and Pair 2 is connected to Pair 3 of the station field Two terminal basic multi point applications are accommodated by connecting row B output to the second terminal common to the multi point circuit 8 Wide Terminating Resistor Adapter 440A4 9 Oo 2 Oo e OOF WO e _ __ e OOF WO 204 Figure Notes 1 8 Wide Plug 2 Cord 3 Plastic Housing 4 8 Wide Jack Terminating Resistor Block 110RA1 12 Figure Notes 1 Circuit 1 2 Circuit 12 3 Output Row A 4 Output Row B 5 Input Row C 6 Only First Circuit Shown to All 12 Circuits 2APR Per Block 7 110D 4
226. clock cabinet does not require a ground connection back to the single point ground Check and Connect Commercial AC Power Begin Return to Task List Before powering up the system check the AC power using a KS 20599 digital voltmeter DVM or equivalent 1 Set the DVM to the 250 volt range 2 Carefully measure the voltage between the hot and neutral side of the receptacle The neutral wire is white the hot wire is black 3 Verify the meter reads 106 to 128 VAC If not have a qualified electrician correct the problem 4 Measure the voltage between the neutral and ground side of the receptacle The ground wire is green 5 Verify the meter reads 0 VAC If not have a qualified electrician correct the problem 6 Set all cabinet power modules OFF Plug the AC power cable into the receptacle Return to Task List Connect DC Power and Ground to Stratum 3 Clock Cabinet Begin Return to Task List Provide power for the clock cabinet from the same DC power plant as the DEFINITY ECS Ground the clock cabinet to the DC power plant Connect Clock Cabinet Grounding Begin Return to Task List 1 Measure and cut a 6 AWG 40 16 mm wire long enough to reach from the clock cabinet to the ground discharge bar in the DC power plant 2 Insert 1 end of the wire into the ground lug on the clock cabinet and tighten the screw 3 Attach the lug to the receptacle cover Be sure the lug and cabinet ground wires connect to
227. connected together with one TDM bus Task List Test the System A CAUTION To prevent unnecessary trouble tickets do not enable the system alarms Alarm Origination feature until all installation and administration procedures are completed 1 Check System Status for Each Cabinet Check Circuit Pack Configuration Test Time Division Multiplexing Bus in Processor Port Network Test Tone Clock Boards Test SPE Duplication Memory Shadowing Link if duplicated Test Duplicated Switch Processing Element Interchange if duplicated Test Time Division Multiplexing Bus for Each Expansion Port Network Test Tone Clock for Each Expansion Port Network Test Tone Clock Interchange for Each Expansion Port Network Test Expansion Interface Exchange for Each Expansion Port Network Check Circuit Pack Configuration 12 Save Translations if Required o ON Oo A2 WO _ ok O LED Indicators Refer to the Maintenance for Avaya MultiVantage DEFINITY Server documentation for detailed alarm and LED descriptions If a maintenance object begins to fail some periodic tests the system generates an alarm The system identifies 3 levels of alarms 125 e Major Alarms Failures that cause critical degradation of service and require immediate attention e Minor Alarms Failures that cause some degradation of service but do not cause a Critical portion of the system to be inoperable This condition requires action but its consequenc
228. connection cydfdr23 KLC 090700 Figure Notes 1 Avaya Media Gateway PPN 2 50 ft 15 m M25A cable RS 232 3 9 to 25 pin adapter if needed 97 4 Computer with Avaya Site Administration PC connections by platform Reliability r si csi Standard Terminal Active TERM TERM High Critical DOT Return to Task List Connect Remotely to the Avaya Media Gateway Through a Data Module Begin Return to Task List If the PC is more than 50 ft 15 m from the Avaya Media Gateway you can connect it through a data module 1 Connect the equipment as shown in A typical remote connection using an 8400B top or 7400B bottom data module Note With a 7400A or 7400B data module use a 4 wire digital line circuit pack With the 8400B data module use a 2 wire digital line circuit pack In place of a 7400B data module you can use a 7400A data module If you do see Set the Data Module to DCE Mode 2 Wire the digital line circuit pack to the wall jack as follows Fora 7400B wire to the second and third pair of the wall jack For an 8400B wire to the first pair of the wall jack After connecting the data module check the Set the Data Module to DCE Mode and perform any necessary tasks Return to Task List A typical remote connection using an 8400B top or 7400B bottom data module 1 o 9 as fo y ole 29
229. connections ITS to network 237 connectors data communications equipment 374 console attendant testing 356 selector testing 356 control carrier cable labels 75 control carrier outputs cable 75 148 control carrier outputs cable installing 57 country codes 113 country options setting 113 coupled bonding conductor 25 87 coupled bonding conductor wires installing 36 coupled bonding connector 60 craft login 107 craft password changing 114 critical reliability testing systems 135 136 critical reliability systems enabling duplication 1 19 CSU 120A adding 280 3150 3170 adding 282 cabling to DS1 converter 311 connecting TN1654 through 311 CSU adding 279 Czechoslovakia country code 113 D damage reporting 18 data communications equipment connector 374 data link protector installing 166 data module 101 102 7400A 338 365 369 7400B 338 365 7400D 365 368 answer only interface 366 modem setting 337 switch settings 365 data module connection to DEFINITY ECS 98 data module DIP switch locations 365 data module settings 96 data module setting to DCE mode 101 data terminals connectable 139 date set procedure 116 daylight savings rules 115 DC power 32 36 318 319 battery interface module installing 33 connecting battery and power cabinet grounds 37 connecting battery cabinet to power cabinet 40 connecting cabinets 39 connecting ground wires 38 rectifier module instal
230. cuit ID 234567889 Facility C Circuit ID 434566335 2 Return to Task List Duplicated DS1 Converter Complex Administration for E1 TN1654 Circuit Packs Return to Task List Fiber Link Administration form for B PNC DS1 Converter DS1CONV Attributes allows you to admininster the DS1 converter The following unique fields display when administering a E1 TN1654 DS1 Converter e Bit Rate Displays when the 051 Converter circuit pack is TN1654 Enter either 1 544 for domestic USA T1 operation or 2 048 for international E1 operation Note Since one bit rate applies for all facilities within the same DS1 Converter complex Bit Rate displays only under Facility A To activate the desired Bit Rate the toggle switch on the circuit pack must be set and it must correspond to the Bit Rate Idle Code MSB 1 LSB 8 Displays when the 051 Converter circuit pack is TN1654 Enter 8 digits each digit must be 0 or 1 The second digit must be 1 Default is 11101000 You can administer this field on a per circuit pack basis 413 CRC Displays when the DS1 Converter circuit pack is TN1654 and the Bit Rate is 2 048 Mbps Enter yes to receive a yellow 2 alarm for E1 operation Default is no You can administer this field on a per circuit pack basis Line Termination A display only field for DS1 Converter circuit packs that are TN1654 and have a Bit Rate of 2 048 Mbps It identifies facility connections as CEPT 75
231. d press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 4 and press Enter Wait until the system has completely reset before continuing Type change cabinet 1 and press Enter In the Carrier Type column change the B carrier to processor and submit the form Type change system parameters duplication and press Enter Setthe Enable Operation of SPE Duplication field to y and submit the form Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 preserve license or reset system 3 no preserve license since the License File has been saved in translations and press Enter Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 and press Enter Wait until the system has completely reset before continuing If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints Type set time and press Enter Ensure that the system date and time are set correctly Use one of these instal
232. dministering PNC Duplication Return to Task List The license file enables PNC Duplication If PNC Duplication is enabled on the System Parameters Customer Options form the following administration forms change Cabinet form Additional fields appear to allow administration of switch nodes to A PNC and B PNC sides of the CSS The B PNC is the duplicated hardware for the A PNC Either the A PNC or the B PNC can provide full customized service B PNC cannot be used in a simplex PNC configuration Pairing of switch nodes is also defined here Fiber Link form Additional fields appear to allow administration of fiber links on the B PNC side of the CSS If an endpoint on the A PNC side is administered as an SNI its corresponding endpoint on the B PNC side is 404 determined if switch nodes are paired in the cabinet form prior to this administration and displayed However administration of the duplicate B PNC link is not enforced until duplication is in full operation Duplication Related System Parameters form An additional field appears to enable operation of PNC duplication Return to Task List Administering Fiber Links Return to Task List Additional fields appear on the Fiber Link Administration form to allow administration of fiber links on the B PNC side of the CSS If an endpoint on the A PNC side is administered as an SNI its corresponding endpoint on the B PNC side is determined if switch nodes are paired in t
233. dministration for Network Connectivity for Avaya Communication Manager for more information on these administration steps and for the steps to administer IP Softphones and H 323 trunks Note The administration of the TN2302AP is the same as that for the TN802B Node Names screen Page 2 of 6 NODE NAMES IP Address Name IP Address 192 168 1 31 192 168 2 31 0 0 0 0 192 168 1 81 IP Interfaces screen change ip interfaces Page 1 of 2 IP INTERFACES Inter region IP connectivity allowed n Enable Net Eth Pt Type Slot Code Sfx Node Name Subnet Mask Gateway Address Rgn C LAN 01 09 TN799 B clan al 255 255 255 MEDPRO 01A13 TN802 B med al 255 255 255 C LAN 01B03 10 255 255 255 MEDPRO 01B09 TN2302 mrmedprol 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 255 192 168 10 21 Heep S355535 BP BBB BBP SPP BBB BKK KK Return to Task List Test the External Connection to the LAN Begin Return to Task List To test the external IP connections ping the C LAN or IP Media Processor server and ping a known computer connected to your network If everything is configured correctly the Result column on the Pin
234. e Detector Call Progress Tone Detector Compatibility Application with CAMA Trunks in Same PN Not Used globally Compatible Compatible Used globally Not Used in the Compatible U S anda few other countries 286 Notes 8 GPTR call classification ports Used for call classification only initially prior to G3V3 3 Becomes a GPTR resource in G3V3 3 and later Use TN744DV2 if CAMA feature is to be supported 8 GPTR call classification ports Required in PN supporting CAMA trunks if GPTR resources are required in excess of those on the TN2182BV2 Also required if the TN768 or TN780 tone clocks are used in place of TN748 TN744 and TN744B and TN744C 4 TTR and 2 CPTR ports Used in combination with the TN756 TN768 or TN780 in many countries initially in versions prior to G3V3 3 Use TN744DV2 if CAMA feature is to be supported Compatibility Tone Clock TTR CPTR GPTR Circuit Packs Circuit Pack TN756 TN768 TN780 TN2182 TN2182B Description with CAMA Trunks in Same PN Tone Not Detector Compatible Generator Tone Clock Not Affected Tone Clock Not Affected Tone Compatible Detector Tone Generator Call Classifier Installing the Circuit Pack Compatibility Application Used in the U S anda few other countries Used in the U S and many other countries Used in the U S infrequently for Stratum 3 clocking and used in many other countries
235. e 1 BCC VALUE TSC CA TSC ITC BCIE Service Feature Numbering LAR of x N IXC user user user user user user 0123 4W Request Format 1 y none both ept outwats bnd BAND none 2 y y y y yn n rest next 3 yyyyyn n rest rehu 4 y yyyyn n rest none 5 y yy yyn n rest none CE n rest av Route Pattern form Page 1 Pattern Number 12 a Page 1 of x Pattern Number 12 Grp FRL NPA Pfx Hop Toll No Del Inserted IXC No Mrk Lmt List Digits Digits I 1 0 1 user 2 user 3 user 4 user 5 user 6 user BCC VALUE TSC CA TSC ITC BCIE Service Feature Numbering LAR 0123 4W Request Format 1 y none both ept outwats bnd BAND none 2 y y yy yn n rest next 3 y yy y yn n rest rehu 4 yyyyyn n rest none 5 yy yyyn n rest none 6 y yyyyn n rest n Return to Task List Changing the CAMA Numbering and Class of Restriction Begin Return to Task List 292 1 At the prompt type change cama numbering and press Enter The CAMA Numbering Format form appears 2 Enter you own system default in the System CESID Default field and press Enter This is the number outpulsed when the extension code is not found in the CAMA Numbering table 3 In the Ext Len Ext Code CESID and Total Length fields fill out to your own CAMA numbering plan and press Enter Be sure to cover all extensions 4 Att
236. e Notes 1 100A Lightguide Interconnect Unit LIU 2 Retainer Rings 3 Circuit Labels Return to Task List 10 Lightguide Connector Panel and Couplings Return to Task List The 10A Lightguide Connector Panel mounts in the cutouts of a 100A Lightguide Interconnect Unit LIU An LIU contains two connector panels Each connector panel can hold six C2000A 2 Connector Couplings Use the C2000A 2 Connector Coupling to join multimode fiber optic cables equipped with ST connectors It has a threaded midsection that allows it to be screwed into the 10A Lightguide Connector Panel Use the C3000A 2 Connector Coupling to join single mode fiber optic cables equipped with ST connectors It has a threaded midsection that allows it to be screwed into the 10A Lightguide Connector Panel Return to Task List Lightguide Troughs Return to Task List 388 Two types of troughs used with optical cross connect hardware The 1A4 trough secures single fiber optic jumpers routed between Lightguide Interconnect Unit LIU columns and the 1A6 trough is used at the bottom of an LIU column to prevent cable slack Fiber Interconnection Cable Return to Task List Both multi mode and single mode fiber interconnection cable are available Multimode Fiber Cable The multimode fiber interconnection cables are used as patch cords and to connect fiber optic equipment to lightguide cross connect and interconnect fields This is a dual fiber cable
237. e Test Results for TDM Bus Port Network 2 is displayed If result is FAIL for any test check the connectors of the TDM bus cables in Processor Port Network PPN 2 Repeat these steps for each Expansion Port Network EPN to check the TDM bus cables test tdm Port PN 02A PN 02A PN 02A PN 02B PN 02B PN 02B Command port network 2 Maintenance Name Alt Name Test No TDM BUS TDM BUS TDM BUS TDM BUS TDM BUS TDM BUS successfully completed Command TEST RESULTS 294 296 297 294 296 297 Result PASS PASS ABORT PASS ABORT PASS Error Code 1005 1005 Return to Task List Test Tone Clock for Each Expansion Port Network Begin Return to Task List 1 Type test tone clock 2A where 2A is the cabinet and carrier number for one of the Tone Clocks installed and press Enter If any result is FAIL check the associated TDM bus cables and intercabinet cables in the Expansion Port Network EPN 2 Repeat Step 1 for each installed Tone Clock circuit pack Test Tone Clock Interchange for Each Expansion Port Network Begin Ret urn to Task List If the system is critical reliability test the Tone Clock interchange for each Expansion Port Network EPN 135 A If Multi Carrier Cabinet MCC1 type status system cabinet number 1 44 and press Enter or If Single Carrier Cabinet SCC1 type status system all cabinets and press Enter This d
238. e of Main Distribution Frame MDF 10 25 Pair Cable to System Cabinet Analog Line Circuit Pack 11 Equipment Room 12 Satellite Location 13 Work Location 14 Bulk Power Supply Such as 1145B Return to Task List Install the Queue Warning Indicator Begin Return to Task List The connections for the queue warning indicator are the same as external ringing An AC indicator lamp such as a 21C49 can be used in a Uniform Call Distribution Direct Departmental Calling UCD DDC queue The lamp is connected to an information outlet The system side of the MDF is connected to an analog line circuit pack located in a port carrier 1 Wire the queue warning indicator to the information outlet as shown in 3 Pair and 4 Pair Modularity and Example Adjunct Power Connections 2 Administer per the Administrator s Guide for Avaya Communication Manager 3 Pair and 4 Pair Modularity 179 26 1 1 2 27 3 9 2 4 28 5 3 6 widf3pm PDH 011397 Figure Notes 1 Port Circuit Pack 2 System Cabinet Connector Pins 3 Pair Modularity 3 Main Distribution Frame MDF Pins 3 Pair Modularity 4 Input to Information Outlet 4 Pair Modularity 5 Adjunct Power 6 Output From Information Outlet 4 Pair Modularity 7 Voice or Data Terminal Pins Example Adjunct Power Connections ce se Se cydfadjn KLC 0
239. e rear of the system cabinets follow these cables to the MDF and to terminate at the CBC Installation Space Requirements This section has information about Sneak Fuse Panels and Emergency Transfer Units 60 110 Type Hardware Cable Slack Manager Sneak Fuse Panels and Emergency Transfer Units 110 Type Hardware Cable Slack Manager Approximately eight inches 20 cm of horizontal wall space is required for each column of sneak fuse panels Horizontal wall space must also be provided for emergency transfer units The trunk auxiliary field and the distribution field are mounted on the same wall Each 110P type terminal block is 8 5 inches 21 6 cm wide Vertical patch cord troughs are 5 31 inches 13 4 cm wide and horizontal patch cord troughs are 23 inches 58 4 cm wide Each 110A type terminal block is 10 81 inches 27 4 cm wide however no horizontal patch cord troughs are used and the blocks are shorter than 110P type terminal blocks This allows the 110A type terminal blocks to be stacked Therefore the 110A type hardware requires less space than the 110P type hardware on a per station basis A Cable Slack Manager is 32 inches 81 3 cm wide Slack managers are commonly used in installations consisting of cabinet stacks The quantity of slack managers is determined by dividing the total length of the Main Distribution Frame MDF in inches cm by 32 81 3 A partial number of 0 4 or less should be rounded down and a p
240. e right of the vertical patch cord trough Repeat Steps 4 5 and 6 If installing another distribution field terminal block partially install the first screw for the terminal block on the line 7 8 in 2 2 cm to the right of the previous screw Partially install the second mounting screw 7 11 16 in 19 5 cm to right of the screw just installed Repeat Steps 4 5 and 6 If installing a vertical patch cord trough in the distribution field repeat Step 6 Repeat Steps 11 and 12 until all the terminal blocks and vertical patch cord troughs in the distribution field are installed 110A Type Terminal Blocks 300 Pair 80 1758420b MMR 03149 Figure Notes 1 4 ft 1 22 m 2 6 6 ft 2 m 3 7 68 in 19 5 cm 4 7 8 in 2 22 cm 5 5 31 in 13 5 cm 6 47 5 in 120 6 cm 7 Horizontal Line 8 AC Power Strip 9 Floor Line 110P Type Terminal Blocks 900 Pair 81 9 9 i 9 9 9 1758421b MMR 031496 Figure Notes 1 4 ft 1 22 m 2 Horizontal Line 3 7 68 in 19 5 cm 4 47 5 in 120 6 cm 5 5 31 in 13 5 cm 6 7 8 in 2 22 cm 7 23 in 58 4 cm 8 8 ft 2 43 m
241. e the alarms in the usual manner Check the error log for evidence of failure The only failure results logged should be the outcome of tests requiring a connected station where a station is not connected to the port under test Repair all other failures or refer them to a maintenance technician for repair 362 Resolve any alarms that may exist using the Maintenance for Avaya MultiVantage DEFINITY Server documentation for your system Return to Task List Activate and Test Alarm Origination Feature Begin Return to Task List 1 Activate the Alarm Origination feature from the change system parameter maintenance form 2 Type test inads link and press Enter to verify the system can reach the INADS Database Administrator at the Technical Service Center TSC 3 Be sure the system is part of the existing INADS database by calling the INADS Database Administrator to verify the system can be dialed into and that the system can dial out to INADS As part of the system registration process the INADS Database Administrator enables Alarm Origination Have the serial number of the system and the software version number available at the time of the call Return to Task List 363 364 Option Switch Settings Some of the interface units used between the system and other types of equipment require specific option switch settings for each application Task List Option Settings Data Module Option Switch Settings and information
242. e to the Ground Discharge Bar See Typical Power and Ground for a DC Powered Cabinet 2 Route the 10 AWG 25 6 mm ground wire to the CBC ground terminal bar at the MDF Be sure a minimum of 12 in 30 5 cm spacing is maintained between the CBC and other power and ground leads 36 3 Tie wrap the ground wire to the inside wiring cable Note The ground wires are connected to the CBC as instructed in Install Telecommunications Cabling Return to Task List Connect DC Battery and Power Cabinet Grounds Begin Return to Task List Note The wire in the next step must be sized for a maximum voltage drop of 0 5 VDC in each leg of the DC distribution In this example 1 AWG is used 1 Measure and cut a minimum of a 1 AWG 70 44 mm wire long enough to reach between the ground connection terminal in the DC Battery Cabinet and the Ground Discharge Bar in the DC Power Cabinet See Typical Power and Ground for a DC Powered Cabinet 2 Crimp terminal lugs on each end of the wire Terminal lugs are furnished as part of D 181895 Kit of Parts 3 At the DC Power Cabinet connect the wire to the Ground Discharge 4 Route the wire through 1 of the holes in the side of the cabinets and terminate it on the Ground Connection Terminal in the DC Battery Cabinet Return to Task List Connect DC Power Cabinet Approved Ground Begin Return to Task List Note The wire must be at least as large as the largest distribution w
243. eady on If the Power and Data LEDs are blinking the unit is not communicating with the Avaya Media Gateway Check the wiring at the MDF wall jack and the 7400B Set the 7400A to DCE mode The Power LED must be steady on The DTR DSR DCD RTS and CTS settings must be highlighted in the display If the Power LED is blinking the data module is not communicating with the Avaya Media Gateway Check the wiring at the MDF wall jack and 7400A Set the Data Module Operating Mode Begin Return to Task List 1 Connect an RS 232 cable from the Avaya Site Administration computer to the data module 2 If you are using an 8400B connect the Avaya Site Administration computer to the data module using the supplied adapter cable 3 Using a terminal emulator connect to the serial port to which the data module is connected and set the emulation to vt100 mode 4 Type AT at the prompt and press Enter 5 The data module should return an OK If it does not be sure that a standard RS 232 or EIA 232 cable is connected not a null modem cable 6 Set the operating mode Type of How to set the operating mode Data Module 8400B Type AT amp F and press Enter Type ATS24 1 and press Enter Type AT amp W and press Enter to save the operating mode into non volatile RAM 7400A Type AT amp F and press Enter Type AT amp W and press 7400 Enter to save the operating mode into non volatile RAM 7 Disconnect the terminal from the data
244. ect Unit LIU or fiber optic shelf Go to Connecting and Handling Fiber Optic Cables for fiber optic equipment connecting to LIUs or shelves and routing through lightguide equipment Use multi mode fiber transceivers and multi mode fiber optic cables between cabinets unless single mode fiber is required distance restrictions Use metallic cables between carriers A CAUTION The DEFINITY ECS may contain a Class 1 LASER device if single mode fiber optic cable is connected to a remote Expansion Port Network EPN Make the required connections for the installation Connect Fiber Optic Cables Connect Standard Reliability CSS Connected System with 1 Switch Node Connect High Reliability CSS Connected System with 1 Switch Node 44 Connect Critical Reliability CSS Connected System with 1 Switch Node Connect Fiber Optic Cables Begin Return to Task List Note Always use the Cable Running List that accompanies the system when installing fiber optic cables The following procedure is a typical example of how to cable a system If the cabinets are close together the signal may go through a single directly connected fiber optic cable If the cabinets are far apart it may be easier to connect the cabinets through an LIU or fiber shelf For each fiber indicated in the fiber optic Cable Running List 1 Install a lightwave transceiver on the cabinet connector at the position in the FROM column in the running list 2 Sel
245. ect a cable indicated by the CABLE CODE and LENGTH in the running list Connect 1 of the fibers to each connector on the lightwave transceivers just installed The fiber is numbered 1 or 2 The connector on the transceiver is labeled TX or RX Keep track of which fiber connects to which transceiver connector Label both ends of these cables 3 Route the fiber optic cables from the transceiver out of the cabinet Secure the cables to the cable tie rack Keep the fiber optic cables clear of the heavier I O cables 4 If the cabinet in the TO column in the running list is located remotely from the FROM cabinet connect to the TO cabinet by way of the LIU Install a lightwave transceiver on the cabinet connector at the position in the column in the running list Route the cables from the FROM cabinet down into the cable trays of each EPN cabinet Connect the cables to the lightwave transceiver just installed on the TO cabinet N Connect the fiber that comes from the TX connector of the FROM transceiver to the RX connector of the TO transceiver and vice versa Route the cables through the cabinet and through cable organizers as provided Secure the cables to the cable tie rack Return to Task List Connect Standard Reliability CSS Connected System with 1 Switch Node Begin Return to Task List Standard Reliability CSS Connected with 1 Switch Node shows typical fiber optic cabling between cabinets The cable betwe
246. ectly from the equipment room MDF to a 356A adapter as shown in 3 Pair to 4 Pair Circuit Distribution and Connectivity Four pair station cables connect the adapter to the information outlets Four pair station cables can be run directly from a satellite location to the information outlets as previously described Note Bridged taps are not allowed on any part of the station wiring 4 Pair Circuit Distribution and Connectivity 1764797a CJL 031396 Figure Notes 1 Part of Main Distribution Frame MDF 2 3 Pair Connecting Blocks 3 4 Pair Connecting Blocks 4 Purple Field 5 Blue Field 6 Patch Cord or Cross Connect Jumpers 7 To System Cabinet Three Pair Modularity 8 B25A Cable 66 9 Connectorized Staggered Finger Multiple 25 Pair Cable 10 258A or BR2580A Adapter 11 Information Outlet 12 4 Pair Circuit 13 DIW Station Cable D Inside Wire 4 Pair Run to Equipment Room or Satellite Location gt 9 764798 CJL 030796 Figure Notes 1 Station Side of MDF or Satellite Location 2 4 Pair Circuit 3 Blue Field 4 DIW Station Cable D Inside Wire 5 Information Outlet 4 Pair Run to Equipment Room or Satellite Location 758532 CJL 031196 Figure Notes 1 Part of MDF 2 3 Pair Connecting Blocks 3 4 Pair Connecting Blocks 4 Purple Field 5 Patch Cord or Cross Connect Jumpers 6 Blue Field 7 To System Cabinet 3 pair modularity
247. ed 4 Type disable filesystem board UUCSS and press Enter to disable the file System on the source circuit pack Note This command is successful only if no files remain on the source circuit pack This completes the self and C LAN distributed download procedures Troubleshooting firmware downloads Aborting a firmware download Testing firmware download This section contains these troubleshooting subsections Aborting a firmware download on page 352 e Testing firmware download on page 352 e Backing out of a firmware download page 353 You can only abort disable cancel a scheduled download that has not yet started Any download currently in progress to a circuit pack finishes For example if you had scheduled a C LAN distributed download to multiple targets and the download was in progress to the first circuit pack when you disabled the download then the download would stop after the completion of the first circuit pack s download and the remainder of the circuit packs would not receive the download To abort a self or C LAN distributed firmware download enter the SAT command disable firmware download You can test a self or C LAN distributed firmware download either before a scheduled download has begun or after an attempted download has reported errors 1 Type test firmware download and press Enter to display the Test Results Screen If the download has already begun the test is denied 352
248. ed the same as on 110 type connecting blocks by moving the patch cord from one point on the Main Distribution Frame MDF to another Optical interconnects consist of Lightguide Interconnect Units LIUs without a trough between them Typical Optical Interconnect Field shows a typical Interconnect field Incoming and outgoing multi mode and single mode cables are connected directly to each other This arrangement makes circuit changes more difficult but reduces optical losses Task List Optical Cross connect and Interconnect Hardware Descriptions 100A Lightguide Interconnect Unit 385 10A Lightguide Connector Panel and Couplings C2000A 2 Connector Coupling Multi Mode or C3000A 2 Connector Coupling Single Mode e Lightguide Troughs 1A4 Lightguide Trough and 1A6 Lightguide Trough Fiber Interconnection Cable Multi Mode or Single Mode Fiber Interconnect Cable e Labels for Fiber Optic Cables Typical Optical Lightguide Interconnect Unit 9 7 is 1781476b MMR 031496 Figure Note
249. een the Avaya Media Gateway or Server and IP phones This power unit also works with the X330 Ethernet expansion module Return to Task List Attendant Console Example Return to Task List These links provide specific information Attendant Console Cabling Distances Local and Phantom Power Auxiliary Power 153 Hard Wire Bridgin Dual Wiring of Two Wire and Four Wire Endpoints Task List Attendant Console Procedures Install the Attendant Console Install the 26B1 Selector Console Attendant Console Cabling Distances Local and Phantom Power The maximum distance from the system for the 302C1 hardwired consoles is shown in Attendant Console Cabling Distances Note IP Softconsole installations are not subject to these distance limitations Attendant Console Cabling Distances Enhanced Attendant 24 AWG Wire 26 AWG Wire Console 302C1 0 5106 mm 0 4049 mm Feet Meters Feet Meters With Selector Console Phantom powered 800 244 500 152 Locally powered 5000 1524 3400 1037 Without Selector Console Phantom powered 1400 427 900 274 Locally powered 5000 1524 3400 1037 Auxiliary Power A CAUTION Do not use the 329A power unit for the attendant console The nonessential functions of an attendant console and its optional 26A1 or 24A1 selector console derive their power from an auxiliary power source Of the maximum of 27 attendant consoles 3 of the consoles can derive auxiliary power from the system and through the au
250. electric shock when the products are subsequently used Power down the power unit see label on power unit on how to do this and refer servicing under the following conditions If liquid has been spilled into any of the products If any of the products have been exposed to water If any of the products do not operate normally If any of the products have been dropped or damaged If any of the products exhibits a change in performance Do not attempt to recharge batteries on your own The batteries may leak corrosive electrolyte or explode The 1145B power unit recharges the batteries safely 2 Remove the batteries if the power unit will not be used for a long period of time several months or more since during this time the battery may leak Discard discharged batteries as soon as possible Discharged batteries are more likely to leak Do not store batteries in high temperature areas Batteries stored in a cold environment should be protected from condensation during storage and warming Batteries should be stabilized at room temperature prior to use after cold storage Do not install batteries if the manufacturing date on the label indicates that the batteries are more than six months old Return to Task List 187 Install the Wall Mounting Plates Begin Return to Task List The top plate is used for mounting the back up battery The bottom plate is used to mount the power supply and distribution units The plates ca
251. ement Circuit Packs Task List Add Multiple Announcement Circuit Packs TN750C Announcement Circuit Pack The TN750C circuit pack contains on board flash memory which provides internal backup of announcements on the circuit packs Thus the TN750C circuit pack does not need the save and restore processes However you can use the save and restore processes to copy announcements from the TN750 or TN750B to a TN750C circuit pack 212 The TN750C circuit pack can replace a TN750 or TN750B circuit pack The difference in operation is that the TN750C circuit pack automatically restores and reports the availability of announcements from its own internal flash memory in 5 minutes rather than the approximately 40 minutes for the TN750 or TN750B circuit pack reporting from the mass storage system If a circuit pack already has announcements in its flash memory the yellow LED flashes as the announcements copy to the Voice RAM TN2501AP Announcement Circuit Pack Important File Specifications The TN2501AP integrated announcement circuit pack e Offers up to 1 hour of announcement storage capacity requires shorter backup and restore times _ is firmware downloadable e plays announcements over the TDM bus similar to the TN750C has 33 ports including 1dedicated telephone port for recording and playing back announcements port number 1 1 ethernet port port number 33 31 playback ports ports 2 32 10
252. emergency transfer mode and make call using emergency transfer telephone There may be up to 4 Emergency Transfer switches depending on the system configuration The switch is located on the Processor circuit pack s in the Processor Port Network PPN Control Carrier Test Remote Access Interface Begin Return to Task List Test the communication link between the system and the remote interface formerly INADS and verify the alarm notification process Make a remote test from the remote interface to the Avaya Media Gateway and a local test from the Avaya Media Gateway to the remote interface In some countries this remote access interface is not allowed Contact your Avaya representative Remote Test Begin Return to Task List 1 Call outside personnel who will be accessing the system remotely to perform administration maintenance and testing 2 Ask remote personnel to call system and login and display System Parameters Maintenance screen The login must be successful Note Product Identification on the System Parameters screen must match the Product Identification administered by the local technician 3 Have the remote personnel type test inads link and press Enter terminate the login and disconnect 4 Have the remote personnel check the appropriate trouble ticket The trouble ticket should show INADS n MINOR in the description field to indicate a minor off board alarm was reported to the remote personnel There
253. en the El and SNI on the PPN is a pre installed metallic cable H600 278 1 If no running list is available use the outer slots first in alternating order Connect the first 2 SNI slots to 3 and 20 the leftmost and rightmost of the unused slots Next use 4 and 19 and so forth 2 Add links to the EPNs in alternating order 20 3 19 4 18 5 and so forth Standard Reliability CSS Connected with 1 Switch Node 45 9 TMM b d Boe CEE La Figure Notes 1 Cabinet 1 PPN with 1 Switch Node 2 Cabinet 2 through 16 EPN 3 H600 278 Metallic Cable 4 To other EPNs Return to Task List Connect High Reliability CSS Connected System with 1 Switch Node Begin Return to Task List High Reliability CSS Connected with 1 Switch Node shows typical fiber optic cabling between cabinets The cable between the El and SNI on the PPN cabinet is a pre installed metallic cable H600 278 Connect the cables between the PPN cabinet and each EPN cabinet in an alternating port slot order 3 19 4 18 5 17 and so forth Cabinet 1 is a PPN with 1 Switch Node High Reliability CSS Connected with 1 Switch Node 9 9
254. equipment networked to your Avaya products TCP IP Facilities Customers may experience differences in product performance reliability and security depending upon network configurations design and topologies even when the product performs as warranted Standards Compliance Avaya Inc is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Avaya Inc The correction of interference caused by such unauthorized modifications substitution or attachment will be the responsibility of the user Pursuant to Part 15 of the Federal Communications Commission FCC Rules the user is cautioned that changes or modifications not expressly approved by Avaya Inc could void the user s authority to operate this equipment Product Safety Standards This product complies with and conforms to the following international Product Safety standards as applicable Safety of Information Technology Equipment IEC 60950 3rd Edition including all relevant national deviations as listed in Compliance with IEC for Electrical Equipment IECEE CB 96A Safety of Information Technology Equipment CAN CSA C22 2 No 60950 00 UL 60950 3rd Edition Safety Requirements for Customer Equipment ACA Technical Standard TS 001 1997 One or more of the following Mexican national standards as applicable NOM 001 SC
255. equipped with ST connector plugs on each end The following components are used in multi mode fiber optic connections Expansion Interface El circuit packs in port slots in cabinet carriers e Cables from each interface circuit pack to each port slot connector The 9823A lightwave transceiver transmits up to 4900 feet 1 5 km The 9823B lightwave transceiver transmits up to 25 000 feet 7 6 km Multimode fiber optic cable consists of two separate 62 5 micrometer diameter fiber optic cables or 50 micrometer diameter fiber optic cables Single mode Fiber Cable The single mode fiber interconnection cables are used as patch cords and to connect fiber optic equipment to lightguide cross connect and interconnect fields This is a dual fiber cable equipped with ST connector plugs on each end Note 5 and 10dB attenuators are available Contact your Avaya representative for more information The following components are used in single mode fiber optic connections Expansion Interface El circuit packs in port slots in cabinet carriers e Cables from each interface circuit pack to each port slot connector 300A lightwave transceivers transmits light up to 115 000 feet 35 km Fiber loss must be less than 17dB Saturation may occur if distances are short attenuators may be required if the total loss on the fiber link is less than 10dBm An Optical Time Domain Reflectometer OTDR test is recommended to determine specific
256. er modem You can set options for the 7400B through a dumb terminal Options for D Lead and Attention Control Modems Set Option Display Option D Lead Attention Seitings Control Settings Set 300 Speed 300 Note 1 Note 1 Set 1200 Speed 1200 Note 1 Note 1 Set 2400 Speed 2400 Note 1 Note 1 Set 4800 Speed 4800 Note 1 Note 1 Set 9600 Speed 9600 Note 1 Note 1 Set 19200 Speed 19200 Note 1 Note 1 Set AT Control AT OFF ON Set Cl Lead Cl Note 2 Note 2 Set Cl2 Lead Cl2 Note 2 Note 2 Set CH Lead CH Note 2 Note 2 Set CH2 Lead CH2 Note 2 Note 2 Set LL Lead LL Note 2 Note 2 Set REMOTE Loop REMLOOP Grant Grant Set RL Lead RL Note 2 Note 2 Set SIGLS Disc SIGLS DISC ON ON Set TM Lead TM Note 2 Note 2 Note 1 Set speed to match remote modem At least one speed must be set ON Note 2 Set to match remote modem 338 Return to Task List 339 340 Upgrade Firmware on Programmable Circuit Packs You can download new firmware to specific programmable circuit packs Programmable circuit packs have a in their suffix For example TN799DP is programmable but TN799C is not This programmable capability reduces the need to physically remove circuit packs and return them to Avaya for firmware updates You can download firmware to one or more programmable circuit packs of the same type residing within the same configuration During this firmware download process a firmware image is installed on a circuit pack in three steps
257. er supply is providing 48 VDC at 80 mA maximum The power LED should be ON Check wiring connections Verify there is dial tone on all emergency transfer sets If all of the above conditions are not met remove the panel from service and replace it with a new panel 9 Check the system for transfer operation as follows Place the test switch switch 12 in the ACTIVATED position The power LED should be OFF Verify there is dial tone on all emergency transfer sets If all of the above conditions are not met remove the panel from service and replace it with a new panel 808A Emergency Transfer Panel 171 EMERGENCY TRANSFER PANEL TRUNK TEST SWITCHES CIRCUIT TRUNK OPTION Crs Loop GROUND oe 2 START START 3 BOTH SWITCHES MUST BE THROWN TO ACTIVATE 4 TRUNK OPTION TRANSFER TEST SWITCH NORMAL OPERATION TRUNK IDENTIFICATION TRUNK LINE Loc led808a LJK 040896 Figure Notes 1 808A Emergency Transfer Panel 2 Circuit Start Selection Switches 3 Trunk Identification Label 4 25 Pair Male Connector Trunk Test Switches Switch Circuit Number Number 1 1 2 1 3 2 4 2 5 3 6 3 7 4 8 4 9 5 172 Trunk Test Switches Switch Number 10 11 12 Circuit Number 5 Not Used Test Switch Pin Assignments for 25 Pair Connector 26
258. er the TN799x C LAN Administer the IP Interface Test the External Connection to the LAN o ON Oo 25 WO M e Prepare for Installation Begin Return to Task List Have the following equipment on site before your shipment arrives AC power outlets for the modem and monitor e Three unoccupied and adjoining port slots in the DEFINITY ECS for the TN802B IP Interface if needed The TN802B occupies only one slot but it needs the two slots to its left for clearance A 10 BaseT or 10 100 BaseT Ethernet connection into your local area network for the TN802B One or more valid unused IP addresses on your network that can be assigned to the IP Interface server You also need the subnet mask and default gateway An analog telephone line reserved DID is okay for the IP Interface diagnostic modem A valid telephone number reserved for the IP Interface diagnostic modem 246 In addition if non U S customer Modem comparable to a U S Robotics Sportster Model USR 33 6 EXT Cable from modem to TN802B external cable assembly We recommend that you protect your cabinet with an uninterruptible power system UPS If adding a TN799DP C LAN circuit pack unoccupied port slot for the TN799DP if needed If you have an existing TN799x circuit pack replace it with the TN799DP A 10 BaseT Ethernet connection into your local area network for the TN799DP or more valid unused IP addresse
259. erface equipment 9 9 9 hidfcsu2 KLC 091499 3 Customer provided network interface equipment 4 Network interface Adapter Descriptions Type Color Description Straight Black Cable with a DB15 connector on one through end and an RJ48 connector on the other Rollover Gray Cable with a DB15 connector on one end and an RJ48 connector on the other Null Black A DB15M to DB15F rollover null adapter DS1 Converter Circuit Pack Switches 3138 rad TS 2 N x A o tc I t o VBSYSSSsssgo DODIRA 2 E oM B So N lar T T 7 N ar NSW ckdfds1 091499 CAMA Numbering Format form E Page 1 E CAMA NUMBERING E911 FORMAT System CESID Default 5241100 Ext Ext Total Ext Ext Total Len Code CESID Length Len Code CESID Length 4 101 5381234 7 4 1 555 7 Y Cable Lengths Length Description 14 in 35 6 cm TN1654 circuit pack to adjacent El circuit pack or TN573B SNI circuit pack in same carrier 70 in 178 cm TN1654 circuit pack to El circuit pack or SNI circuit pack in another carrier 14 in 35 6 cm TN1654 circuit pack to fiber optic transceiver DC powered cabinets only This cable is for intercabinet cabling only 314 Return to Task List Mounting the 127A TN1654 DS1 Converter
260. es 6 If using external alarm equipment attach the supplied DW8 cable to the 120 and the external equipment The maximum length of this cable depends on the alarm equipment If a TN464F is used make sure the circuit pack is set for 24 channel operation Set the switch on the circuit pack 8 From the DS1 circuit pack form of the system administration console set the line compensation field to 0 133 feet 40 6 m 280 9 Reset the 120 by reseating the DS1 circuit pack When you reinsert the DS1 circuit pack after installing a 120A3A CSU the 120A3A resets The 051 circuit pack initializes and tests the 120A3A When initialization and testing is complete the green LED goes off If the RED indicator is OFF after the test the ICSU is working 10 If the circuits do not pass the self test troubleshoot the 120A3A as instructed in Integrated CSU Module Installation and Operation H700 383 Cable Pin Assignments provides the H700 383 cable pinouts H700 383 Cable Lengths by Group Number provides the cable lengths for each cable group number 120A3A Channel Service Unit Module 9 19 18 09 Q Figure Notes 1 Rear of carrier containing DS1 circuit pack 2 120A3A CSU 3 4 pair cord to network interface H700 383 4 DW8A DE 4 pair cord to alarm contacts optional 5 To 25 pair connector on rear of carrier containing DS1 circuit pack H700 383 Cable Pin Assignments Pin Color Chan
261. es are not immediate Problems might be impaired service to a few trunks or stations or interfering with one feature across the entire system Warning Alarms Failures that cause no significant degradation of service or failures in equipment external to the system Warning alarms are not reported to the attendant console or INADS Alarms are communicated to the system users and technicians by entries in the alarm log and the lighting of LEDs located on the attendant console on all circuit packs and optionally on customer designated voice terminals More detailed information is available here for Attendant Console LEDs Terminal Alarm Notification e Circuit Pack LEDs DS1 Converter Circuit Pack LEDs SPANLEDs e LEDS on Standby Components Attendant Console LEDs The console has 2 red LEDs labeled ALM and ACK The ALM LED lights steadily when there is a major or minor alarm at the system cabinet The ACK LED lights steadily if the alarm has been successfully reported to INADS If the system is unable to report the alarm to INADS the LED flashes this signals the attendant to call INADS and report the alarm Terminal Alarm Notification Terminal Alarm Notification is an optional feature that displays several types of alarms on voice terminals with administered feature buttons or the attendant console A maximum of 10 digital and or hybrid voice terminals may be used When an alarm occurs the green
262. es the 25 pair cable into eight 3 pair circuits Although the circuits are 3 pair the adapters modular jacks will accept the 8 wide modular plug used on the 4 pair station cable A CAUTION Adapters wired similarly to the 356A should not be used Their jacks do not accept 4 pair plugs Use theZD8AJ adapter to connect a Multi button Electronic Telephone MET line cord to an information outlet The adapter interchanges pairs 3 and 4 to correspond with the pair assignments for the telephone The line cord plugs into the adapter and then the adapter plugs into an information outlet Satellite locations are closets that provide an administration point using cross connect equipment for station cables and where adjunct power may be applied The station cable circuits from the equipment room are 3 pair At the satellite location 4 pair circuits run to the information outlets The hardware used is 110 type terminal blocks Satellite Locations Using 110 Type Hardware Each terminal block has a 3 pair white field and a 4 pair blue field located on the same terminal block The 110A type terminal block that can be used is the 110AE1 75FT It must be field terminated to both the white and blue fields The 300 pair 110P type terminal blocks that can be used are e 110PE1 S00CT FT 25 pair connector on the white field and field terminated on the blue field 110PE1 300FT Field terminated on both the white and blue fields
263. est Integrated Announcement Begin Return to Task List The TN750B C and TN2501AP Announcement circuit packs provide the ability to store messages The messages can be recorded from telephones on or off premises and have flexible message lengths The telephone selected as the test telephone must have a class of service COS with console permission enabled Record Announcement Begin Return to Task List 1 Select test telephone with console permission enabled 2 Dial the access code followed by the integrated announcement extension number Dial tone is heard 3 Dial 1 A short burst of tone is heard and recording begins Speak the announcement into the telephone 4 Dial or hang up Recording stops and dial tone is heard Return to Task List Playback Announcement Begin Return to Task List 1 Dial access code followed by the integrated announcement extension number Dial tone is heard 2 Dial 2 The announcement is heard and dial tone is heard at completion of announcement Delete Announcement Begin Return to Task List 1 Dial access code followed by the integrated announcement extension number Dial tone is heard 357 2 Dial 3 A confirmation tone is heard and announcement is deleted Test Music on Hold Begin Return to Task List Verify music is provided to a held party during any hold interval Test Emergency Transfer Begin Return to Task List Put system in
264. etting 1 rapidly minimizes echo when first detected regardless of the loudness of the talker s voice Settings 1 and 4 have the same EC settings except that Setting 1 introduces 6 dB of loss Setting 2 minimizes speech clipping but it takes a fraction of a second longer for the echo to fade Setting 3 eliminates speech clipping but a strong echo may take 2 or 3 seconds to fade 8 If after trying all these settings the echo still exists contact technical support For telephone numbers go to Avaya Support Centre and select ONLINE SERVICES then select Contact Us Trunk Features screen add trunk group next Page 2 of 11 SPE A TRUNK FEATURES ACA Assignment n Measured both Internal Alert n Maintenance Tests y Data Restriction n Glare Handling none Used for DCS n Suppress Outpulsing n Seize When Maintenance Busy neither end Incoming Tone DTMF ANI no Per Call CPN Blocking Code Connected to CO n Per Call CPN Unblocking Code 1 Echo Cancellation DS1 Circuit Pack screen 231 add 451 2b08 Page 1 of 1 SPE B DS1 CIRCUIT PACK Location 02B08 Name Echo Cancel t23 Bit Rate 2 048 Line Coding hdb3 Signaling Mode CAS Interconnect pbx Country Protocol 1 Interface Companding mulaw CRC n Idle Code 11111111 Slip Detection y Near end CSU Type other Echo Cancellation y EC Direction inward EC Configuration 1 Return to Task List 232 Add IP Solutions Avaya offers several I
265. etween the switch and RFA No connection between the switch and RFA Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 4 and press Enter Wait until the system has completely reset before continuing Type change cabinet 1 and press Enter In the Carrier Type column change the B carrier to processor and submit the form Type change system parameters duplication and press Enter Setthe Enable Operation of SPE Duplication field to y and submit the form Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 preserve license or reset system 3 no preserve license since the License File has been saved in translations and press Enter Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 and press Enter Wait until the system has completely reset before continuing If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints Type set t
266. f the MDF Main Distribution Frame The preferred location of the Main Distribution Frame MDF is directly behind the Single Carrier Cabinet SCC1 stack or the Multi Carrier Cabinet MCC1 Typical 110A Type Terminal Blocks SCC1 shows a typical SCC1 Single Carrier Cabinet installation using 110A type terminal blocks and Typical 110P Type Terminal Blocks MCC1 shows a typical Multi Carrier Cabinet installation using 900 pair 110P type terminal blocks Typical 110A Type Terminal Blocks SCC1 H d NT y N TS SS gt 1 E SSS y SSS SS D NN y D y y SSS Is 2 SS b N 1758534 CJL 042996 Figure Notes 1 Single Carrier Cabinets Stacked SCC1 53 2 Z113A Cable Slack Manager 3 25 Pair Cable to System Cabinet 4 Station Cables 5 Station Distribution Field 6 Port Distribution Field 7 Trunk Auxiliary Field Typical 110P Type Terminal Blocks MCC1 mcecmdf 060596 Figure Notes 1 Multi Carrier Cabinet MCC1 2 Z113A Cable Slack Manager 3 25 Pair Cable to System Cabinet 4 Station Cables 5 Station Distribution Field 6 Port Distribution Field 7 Trunk Auxiliary Field Main Dist
267. f the connector is not being used immediately cover the connector with the dust cap 390 Install Fiber Optic Cable Pass Thru Kit for MCC1 Multicarrier Cabinets This section details the installation of the fiber optic pass thru kit for multi carrier cabinets MCC1 only This kit provides the equipment necessary to install the fiber optic connectors and associated cabling Install the fiber optic cable pass thru kit MCC1 LASER Product Use this task list to install the fiber optic cable in the MCC1 multicarrier cabinet 1 Prepare the cabinet 2 Install the Pass Thru Kit 3 Test the Installation CLASS 1 LASER PRODUCT IEC 825 1993 The Avaya Media Gateway may contain a Class 1 LASER device if single mode fiber optic cable is connected to a remote Expansion Port Network EPN The LASER device operates within the following parameters Maximum Power Output 5dBm Wavelength 1310 nm Mode Field Diameter 8 8 microns A caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Contact your Avaya representative for more information Prepare the cabinet Begin Return to Task List 1 Verify the equipment received See Fiber pass thru kit equipment Actual equipment may vary in appearance and may ship in separate packages 2 Open the front door Note Administration may be required before removing the circuit pack in the foll
268. following commands to administer the Fiber Link Administration form Action Object Qualifier add fiber link link number or next change fiber link link number display fiber link link number list fiber link link number remove fiber link link number 403 PN reliability configurations PNCs have three different reliability configurations one for each system reliability configuration as follows System Configuration PNC Standard Reliability Simplex Fibers High Reliability Simplex Fibers to Expansion Port Networks and Duplicated Fibers between Processor Port Networks PPN and Switch Nodes Critical Reliability Duplicated Fibers Simplex PNC For Simplex PNC PNC Duplication is disabled with a license file and Duplication is disabled on the Duplication Related System Parameters form Task List Administration Details For details of administration select the topics that relate to your installation Administering PNC Duplication e Administering Fiber Links Duplicated Fiber Link Administration DS1C Converter Complex Administration for TN574 Circuit Packs Duplicated DS1C Converter Complex Administration for TN574 Circuit Packs DS1 Converter Complex Administration for T1 TN1654 Circuit Packs Dupicated DS1 Converter Complex Administration for T1 TN1654 Circuit Packs DS1 Converter Complex Administration for E1 TN1654 Circuit Packs Duplicated DS1 Converter Complex Administration for E1 TN1654 Circuit Packs A
269. g DCP or ISDN T voice terminal equipped with an adjunct jack A CAUTION The power supply can be used only with telecommunications equipment indoors and in a controlled environment The power supply has a single output of 48 VDC 0 4 Amps and can operate from either a 120 VAC 60 Hz power source 105 to 129 VAC or a 220 230 240 VAC 50 Hz power source 198 to 264 VAC Input voltage selection is automatic The output capacity is 19 2 Watts The power supply can be placed on a flat surface such as a desk For wall mounting keyhole slots are provided on the bottom of the chassis A caution Do not locate the unit within six inches 15 25 cm of the floor Return to Task List Important Safety Instructions for 1151A1 and 1151A2 Power Supplies Return to Task List Please read the following helpful tips Retain these tips for later use When using this power supply the following safety precautions should always be followed to reduce the risk of fire electric shock and injury to persons Read and understand all instructions Follow all warnings and instructions marked on this power supply This product can be hazardous if immersed in water To avoid the possibility of electrical shock do not use it near water To reduce the risk of electric shock do not disassemble this product except to replace battery This product should be operated only from the type of AC power source indicated on the label If you are not sure of the
270. g Results screen reads pass If it reads abort verify the IP address information and check the connectivity including the cabling 1 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the IP Media Processor and UUCSS is the cabinet carrier and slot of the IP Media Processor 2 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the customer s gateway and UUCSS is the cabinet carrier and slot of the IP Media Processor 3 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of another computer beyond the gateway and UUCSS is the cabinet carrier and slot of the TN2302AP IP Media Processor The IP Media Processor is now installed in the carrier and connected to the IP network Ping Results screen 240 ping ip address 192 168 10 21 PING RESULTS End pt IP Port Port Type Result Time ms Error Code 192 168 10 21 01A13 MEDPRO PASS 10 1124 Return to Task List Upgrading TN802 IP Trunking to TN2302AP IP Media Processor Return to Task List To upgrade IP Trunking to IP Media Processor you must replace the TN802 circuit pack with a TN2302AP circuit pack the TN799 circuit pack with a TN799DP circuit pack the H600 512 G1 external cable assembly with an IP Media Processor adapter Task List Upgrade TN802 to TN2302AP Perform these tasks to up
271. g TN1654s in a Switch Node Carrier Begin Return to Task List You can install up to 2 TN1654 circuit packs in a Switch Node Carrier 1 Install the TN1654 circuit pack in either slot 1 or 21 of the Switch Node Carrier close to a TN573B SNI circuit pack A CAUTION Install the TN1654 circuit pack in either slot 1 or slot 21 Installing it in any other slots can damage the circuit pack and the system Do not do it 2 On the backplane connect a 14 inch 35 56 cm Y cable from the TN1654 circuit pack to the TN573B circuit pack See DS1 Converter Connections Part 1 A CAUTION The Y cable used with the TN1654 circuit pack is different than the Y cable used with the TN574 circuit pack These cables are NOT interchangeable 3 Connect an H600 348 Quad cable to the other side of the Y cable 4 Skip to Connecting Through a Channel Service Unit 310 DS1 Converter Connections Part 1 cydf010 KLC 091399 Figure Notes 1 Port cabinet 2 Backplane connector for TN570C EI 3 Backplane connector for TN1654 DS1 Converter 4 50 pair female connector to El connector 5 14 in 35 6 cm Y cable 6 50 pin male 50 pin female double headed connector 7 H600 348 Quad Cable with 50 pin male connector which connects the Y cable to the 4 CSUs Return to Task List Connecting a Port Carrier to a Switch Node Carrier TN1654 DS1 Converter Begin Return to Task List 1 When the TN1654
272. generate alarms resulting in unnecessary trouble tickets 3 Type neither in the Alarm Origination to OSS Numbers field and press Enter Return to Task List Save Translations DS1 Tie and OPS Trunks Begin Return to Task List 1 If the system is high or critical reliability type status system 1 and press Enter to verify that the system is in the active standby mode 299 2 Type save translation and press Enter This instructs the system to take all translation information in memory and write it to the translation card or removable media 3 If the system contains a TN750 B Announcement circuit pack type display announcements and press Enter If administered recorded announcements are listed type list configuration software version press Enter Check Page 2 of this form to see when the announcements were last saved To save the current announcements type save announcements and press Enter Shut Down DEFINITY LAN Gateway System DS1 Tie and OPS Trunks Begin Return to Task List A WARNING Neglecting to shut down the LAN Gateway assembly before powering down the system cabinet can damage the LAN Gateway disk 1 Log onto the DEFINITY LAN Gateway 2 From the main menu click Maintenance gt Reset System gt Shutdown Shut Down DEFINITY AUDIX System DS1 Tie and OPS Trunks Begin A yellow caution sticker on the system s power unit notifies you to shut down the AUDIX before powering down the system WA
273. grade the TN802 to TN2302AP 1 Perform Pre upgrade Administration 2 Remove the Circuit Packs 3 Replace the Cables 4 Install the Circuit Packs 5 Administer and Test Perform Pre upgrade Administration Begin Return to Task List 1 Type list configuration all and press Enter to locate all the TN802 circuit pack ports N Type display port UUCSSppp and press Enter to find the trunk group number associated with the TN802 circuit pack port 3 Type change trunk group number and press Enter Go to screen 4 Delete all the TN802 ports 4 Repeat steps1 through 3 for each port 5 Type remove ds1 UUCSS and press Enter Remove the Circuit Packs Begin Return to Task List 241 A CAUTION When adding or replacing any hardware be sure to ground yourself against electrostatic discharge ESD by wearing a grounded wrist strap Note The TN799 and TN2302AP circuit packs are hot swappable so you do not need to power down the carrier to remove or install them 1 Press the recessed Reset button on the TN802 circuit pack until MSHUT starts flashing on the LCD When MSHUT is in a steady state it is safe to remove the circuit pack 2 Remove the TN799 and TN802 circuit packs Replace the Cables Begin Return to Task List 1 Disconnect the network cable from the Ethernet connection 2 Turn off the monitor and unplug it from the AC outlet if necessary 3 Disconnect the monitor keyboard and mouse from the H600 512 external
274. h Access 11 Deactivation Code Code Code Code Code Code Code Code ____ All Deactivation Code ____ Code 2 Return to Task List Changing the ARS Digit Analysis Begin Return to Task List 1 At the prompt enter change ars analysis lt 9 gt and press Enter The ARS Digit Analysis Table appears 2 In the Dialed String field in the first empty row enter 11 3 In the Total Mn field enter 2 4 In the Total Mx field enter 2 5 n the Rte Pat field enter the desired Route Pattern in the example the route pattern is 77 Note For the following step if you are using the Attendant Crisis Alerting feature type alrt instead of emer 6 In Call Type field enter emer 7 On the next empty row in the Dialed String field type 911 8 In the Total Mn field enter 3 9 In the Total Mx field enter 3 10 In the Rte Pat field type the desired Route Pattern in the example the route pattern is 72 Note For the following step if you are using the Attendant Crisis Alerting feature type alrt instead of emer 290 11 In the Call Type field enter emer and press Enter ARS Digit Analysis Table a ARS DIGIT ANALYSIS TABLE Partitioned Group Number _ Percent Full _ Dialed Total Rte Call Nd ANI Dialed Total Rte Call Nd ANI String Mn Mx Pat Type Num Rq String Mn Mx Pat Type Num Rq 9 7_7 2 hnpa n 976 7_7 den hnpa n 11 2_ 2 11_ emer n
275. he Ethernet Begin Return to Task List Connect the network cable to the ETHERNET connector on the TN802B external cable assembly You need 5 or better cable for 100 Mbyte operation Install the Circuit Packs Begin Return to Task List A CAUTION When adding or replacing any hardware be sure to ground yourself against electrostatic discharge ESD by wearing a grounded wrist strap Note The TN799B C and TN2302AP circuit packs are hot swappable so you do not need to power down the carrier to install them 1 Insert the TN799x circuit pack into the port slot identified earlier Note To properly seat the circuit pack push firmly on the front of the faceplate until the latch reaches the bottom rail of the carrier Then close the latch until it is fully engaged 2 Insert the TN2302AP IP Media Processor into the port slot you reserved for it and seat it properly See TN2302AP IP Interface faceplate When you plug in the TN2302AP IP Media Processor the circuit pack starts to boot The RED LED stays on until an IP address is assigned to the circuit pack 3 Type list configuration all and press Enter to verify that the system recognizes the TN2302AP circuit packs TN2302AP IP Interface faceplate 237 Return to Task List Perform Initial Administration Steps for C LAN and IP Media Processor Begin Return to Task List Note Refer to the Administration for Network Connectivity for
276. he Minute field Type current minute 0 through 59 Seconds cannot be set Type standard or daylight savings in the Type field 116 10 Type the rule number in the Daylight Savings Rule field 11 Press Enter when the information is correct 12 Verify the screen displays command successfully completed 13 Type display time and press Enter to verify date time data Typical Date and Time Screen DATE Day of the Week Tuesday Month November Day of the Month 3 Year 1998 DATE AND TIME TIME Hour 20 Minute 30 Second XX Type standard Daylight Savings Rule 1 English Day of the Week Names Day Number Day Name 1 Sunday Monday Tuesday Wednesday Thursday Friday DO o Inm Saturday English Month Names Month Number Month Name 1 January February March April May June July August ON DO oO A2 CO September English Month Names Month Number Month Name 10 October 11 November 12 December Conversion to 24 Hour Clock Standard Time Standard Time 12 Hour 24 Hour 12 Hour 24 Hour 12 00 0000 12 00 1200 midnight noon 1 00 am 0100 1 00 pm 1300 2 00 am 0200 2 00 pm 1400 3 00 am 0300 3 00 pm 1500 4 00 am 0400 4 00 pm 1600 5 00 am 0500 5 00 pm 1700 6 00 am 0600 6 00 pm 1800 7 00 am 0700 7 00 pm 1900 8 00 am 0800 8 00 pm 2000 9 00 am 0900 9 00 pm 2100 10 00 am 1000 10 00 pm 2200 11 00 am 1100 11 00pm 2300 Return to Task List Reboot High Reliability System MCC
277. he cabinet form prior to this administration and displayed However administration of the duplicate B PNC link is not enforced until duplication is in full operation The following fields appear for basic fiber link administration Fiber Link Display only field From the command line enter 1 to 3 digit number to uniquely identify a switch connection in the system and its duplicate if appropriate Board Location Enter the cabinet carrier and slot that identifies the physical location of an SNI or EI board that is the first endpoint of the fiber link Board Type Display only field showing the type of circuit pack in Endpoint 1 Board Location Enter the cabinet carrier and slot that identifies the physical location of an SNI or EI board that is the second endpoint of the fiber link Board Type Display only field showing the type of circuit pack in Endpoint 2 Is one endpoint remoted via a D81 Converter Complex Enter y to specify that a DS1 Converter complex is used to remote one endpoint If a y is entered A PNC 051 Converter circuit pack Location must be administered on Page 1 A PNC DS1 Converter circuit pack Type displays A PNC DS1 Converter DS1CONV Attributes must be administered on Page 2 of this form Fiber Link Administration form 7 Fiber Link 1 Is one endpoint remoted via a DS1 Converter Complex Page 1 of 1 FIBER LINK ADMINISTRATION ENDPOINT 1 ENDPOINT 2 A
278. he prompt type change cor lt numbers the class of restriction COR to be changed and press Enter The Class of Restriction form page 1 appears 5 Change all CORs that are defined for stations in order to remove any calling party restrictions for 911 calls 6 Type none in the Calling Party Restriction field and press Enter 7 Type save translation and press Enter CAMA Numbering Format form 1 of CAMA NUMBERING E911 FORMAT System CESID Default 5241100 Ext Ext Total Ext Ext Total Len Code CESID Length Len Code CESID Length 4 101 5381234 7 4 1 555 7 Class of Restriction form page 1 T Page 1 of 3 E CLASS OF RESTRICTION COR Number 10 COR Description supervisor FRL O APLT y Can Be Service Observed n Calling Party Restriction none Can Be A Service Observer n Called Party Restriction none Time of Day Chart 1 Forced Entry of Account Codes n Priority Queuing n Direct Agent Calling n Restriction Override none Facility Access Trunk Test n Restricted Call List n Can Change Coverage n Unrestricted Call List Access to MCT Category For MFC ANI Send ANI for MFE Hear System Music on Hold Automatic Charge Display Can Be Picked Up By Directed Call Pickup NC Can Use Directed Call Pickup Fully Restricted Service Hear VDN of Origin Annc Add Remove Agent Skills PASTE Display PBX Data on Phone SK BAK 5555 3
279. he source C LAN and those target boards 1 Type list fiber link and press Enter 2 Find the link between the source C LAN and the target boards 3 Type display fiber link n where n is the fiber link s number and press Enter to access the Fiber Link Administration screen 4 Goto the page 2 and verify that the Line Coding fields are set to b8zs for T1 facilities and hdb3 for E1 facilities If they are not then escalate before proceeding with the firmware download Get circuit pack information 1 Type list configuration all and press Enter to access the System Configuration screen ist configuration all Board Number Board Type 01A08 IP MEDIA PROCESSOR 01A04 CONTROL LAN 01B04 DS nterface 01B05 DS nterface 01B06 DS nterface 01A10 VAL ANNOUNCEMENT SYSTEM CONFIGURATION Assigned Ports Code Vintage u unassigned t tti p psa TN2302AP HWO3 FWO44 01 02 03 04 05 06 07 08 TN799DP HWOO FW005uuuuuuuu uuuuuuuwu 17 TNA464GP HWO2 FWOO6 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 26 24 uuuuuuuu TN464GP HWO2 FWOO6 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 uuuuu uuuu TN464 u u u uu uu 000038 01 02 03 04 05 uuu uu uu uu cog TN2501AP HW01 FWO04 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 26 24 F 25 26 27 28 29 30 31 32 2 Look for the target circuit pack s
280. high reliability system 118 MCC fiber optic duplication interface cabling 43 MCCI fiber optic pass thru kit 395 install fiber optic cable 391 test fiber optic cable installation 402 MDF alarm connections 157 emergency transfer connections 170 emergency transfer unit 168 off premises connections 161 162 MDF cabling 56 MDF connections multicarrier cabinet 52 MDF connections single carrier cabinet 50 MDF cross connect fields 52 MDF hardware 50 MDF labels 54 MDF location 53 MDF cabling to auxiliary cabinet 79 MDF cabling to cabinet 78 MedPro mode 233 MedPro mode installing 246 248 249 250 253 255 MET line pinouts 415 Mexico country code 113 mixed AC DC powered cabinet connecting 40 modem AT control 369 COMSPHERE 370 connect to telephone network 325 connected to data module 337 connected to DTE 338 D lead 369 network jack pinout 325 pass thru kit 330 modem connection to DEFINITY ECS 99 modem AT control 338 modem connect to EPN 328 modem connect to PPN 329 modem connect to TN1648B 330 modem D lead options 338 modem external 370 modem external switch settings 326 modem pooled 336 modems installing and connecting 325 modularity 3 pair and 4 pair 151 mounting terminal blocks 79 82 multimode fiber optic transceiver 389 multiple announcements adding 212 215 multipoint adapters 206 multipoint installations 208 music on hold testing 358 N
281. iary power alarms 156 attendant console 153 Avaya R300 Remote Office Communicator 233 B backplane pins 419 back up battery 188 189 191 basic rate interface See BRI battery mounting 191 battery cabinet connecting to DC power cabinet 40 battery charger optional 31 battery holdover assembly 28 battery holdover connecting 29 battery interface module installing 33 battery leads connecting 28 battery connecting DC 37 Belgium country code 113 bit rate setting 380 bonding conductor coupled 87 BR2580A adapter 63 BR851 B adapter 206 Brazil country code 113 BRI 203 fanout of multipoint installations 206 multipoint cabling 208 terminating resistor 203 BRI installing 209 210 BRI testing 359 bringing the system online 91 building steel ground 383 cabinet cable clamps 61 cabinet grounds 23 Index cabinet grounds connecting 34 cabinet location auxiliary cabinet 20 EPN cabinet 19 PPN cabinet 19 cabinet cabling to MDF 78 cabinets attaching to floor 22 connecting DC pewer 39 cable diagrams 415 fiber optic 403 single mode 389 fiber optic cleaning 390 fiber optic labels 390 fiber optic multimode 389 cable clamps 84 cable clamps for cable slack manager 61 cable installation control carrier outputs AT cable routing guidelines 57 cable routing MDF 57 cable slack manager installing 84 cable slack manager space requirements 60 cable tests 125 c
282. ical Reliability To Y Cable Clock End Primary Connecting Lead From Stratum 3 Clock Lead Designation REF2LST SCLKRTN SCLKLST SPWRRTN SPWRLST REF1RTN REF1LST CCAO1R CCAO1T CCBO1R CCBO1T CCA02R CCA02T CCBO2R CCBO2T Lead Color BR W R BL BL R R G G R W G G W R S S R BK BL BL BK BK O O BK BK G G BK Block Terminal 8 ALRM3A 11 ALRM2B 12 ALRM2A 15 ALRM1B 16 ALRM1A 5 ALRMOB 6 ALRMOA 19 EXTSYNOT 20 EXTSYNOR 21 EXTSYN1T 22 EXTSYN1R 23 24 25 26 Return to Task List Lead Designation Color BR R R BL BL R Y BL BL Y W BR BR W V BL BL V Y G G Y 324 Connecting Block Terminal 18 11 12 31 32 7 8 41 42 35 36 ALRM3A ALRM2B ALRM2A ALRM1B ALRM1A ALRMOB ALRMOA EXTSYNOT EXTSYNOR EXTSYN1T EXTSYN1R BR R R BL BL R Y BL BL Y W BR BR W V BL BL V Y G G Y 18 11 12 31 32 co N 41 42 35 36 Install and Connect Modems This section provides the information necessary to install and connect modems Note The Avaya Media Gateway si does not require an external modem because an internal modem is in the processor circuit pack Task List Install and Connect Modems Connect Modem to Telephone Network Set External Modem Options Add U S Robotics Model USR 33 6 EXT External Modem to EPN Add U S Robotics Model USR 33 6 EXT External Modem to PPN Add External Modem to TN1648B Add Modem Poolin Connect Modem to Telephone Network
283. ied from the equipment room satellite location or the work location For this figure the following example is used 1 If 25 telephones are connected to the system and all 25 telephones need adjunct power install a bulk power supply in the equipment room 2 If only ten of the telephones need adjunct power install a bulk power supply at the satellite location 3 If only one telephone needs adjunct power install the individual power supply at the work location Example Adjunct Power Connections 152 e Bl e p cydfadjn KLC 020599 Figure Notes 1 Typical Display Telephone 2 Individual Power Supply Such as 1151A1 or 1151A2 3 Information Outlet Modular Jack 4 4 Pair D Inside Wire DIW Cable 5 Satellite Site or Adapter Location 6 25 Pair D Inside Wire DIW Cable 7 Station Side of Main Distribution Frame MDF 8 100P6A Patch Cord or Jumpers 9 System Side of Main Distribution Frame MDF 10 25 Pair Cable to System Cabinet Analog Line Circuit Pack 11 Equipment Room 12 Satellite Location 13 Work Location 14 Bulk Power Supply Such as 1145B Powering IP phones If customers do not want to use local power for their IP phones they can use either the P333T PWR 24 port Cajun switch that provides power over the Ethernet 1152 1 midspan power unit which supplies power betw
284. igination is activated 1 Set the Data Bits field to 8 default 2 Setthe Parity field to none default 3 For non United States installations set the remaining modem fields as shown in SCC1 Modem Fields 4 Press Enter when the modem fields are properly administered 326 U S Robotics Model 839 External Modem Switch Settings Switch Setting Function 1 OFF Up DTR Data Terminal Ready override 2 OFF Up Verbal result codes text formatted feedback characters such as connected or no carrier ON Down Enable result codes OFF Up Displays keyboard commands local echo OFF Up Sets auto answer Verify that the Auto Answer Ring Count rings on the maintenance related system parameters form is 50 10 6 OFF Up CD Carrier Detect override modem sends CD signal on connect drops CD on disconnect 7 OFF Up Power on ATZ reset software defaults loads Y or Y 1 configuration from NVRAM 8 ON Down AT Attention command set recognition enables recognition smart mode SCC1 Modem Fields Field Description Modem Default is none Set to external if a modem is used Connection Modem Name RTS CTS Enabled Asynchronous Data Mode DTE Auto Data Speed Disable Data Compression Enable Error Control This field is 20 characters long and permits alphanumeric characters to provide a unique qualifier for a given modem Informs modem that communication with the data source UART is driven with RTS CTS flow contro
285. ign an IP Address Assign Default Gateway if you use gateways Check Network Services Test the External Connection to the LAN Test the IP Interface Onboard LAN Connections Prepare for Installation Begin Return to Task List Have the following equipment on site before your shipment arrives 256 AC power outlets for the modem and monitor e Three unoccupied and adjoining port slots in the DEFINITY ECS for the TN802B IP Interface if needed The TN802B occupies only one slot but it needs the two slots to its left for clearance A 10 BaseT or 10 100 BaseT Ethernet connection into your local area network for the TN802B One or more valid unused IP addresses on your network that be assigned to the IP Interface server You also need the subnet mask and default gateway analog telephone line reserved DID is okay for the IP Interface diagnostic modem A valid telephone number reserved for the IP Interface diagnostic modem In addition if non U S customer Modem comparable to a U S Robotics Sportster Model USR 33 6 EXT e Cable from modem to TN802B external cable assembly We recommend that you protect your cabinet with an uninterruptible power system UPS Return to Task List Check your Shipment Begin Return to Task List When your DEFINITY IP Interface Assembly order arrives at your site check the contents see Required Hardware 1 Inspect the shipping carton for d
286. ime and press Enter 222 New or upgraded G3si only Ensure that the system date and time are set correctly 5 Use one of these installation methods Direct connection between the switch and RFA No connection between the switch and REA 1 Retrieve the RFA License File with both serial numbers from the RFA Application 2 If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints 3 Type set time and press Enter Ensure that the system date and time are set correctly 4 For duplicated systems only type status system all and press Enter Ensure that the standby SPE is notin the maintenance state If it is wait for the maintenance state to finish 5 Use one of these installation methods Direct connection between the switch and RFA No connection between the switch and RFA Direct connection between the switch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File Note This procedure sends the License File to the switch and installs it 2 If the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints No connection between the switch and RFA 1 Goto the RFA website and following the instructions in the Deliver to
287. ing For the 4C3S 75 protector there are a variety of 25 50 and 100 pair protector panels equipped with 110 type connecting blocks and or RJ21X connectors Installing the Data Link Protector Return to Task List The maximum range for out of building digital voice terminals is 3400 feet when using 24 AWG 5 0 5 mm wire and 2200 feet 670 m when using 26 AWG 4 0 4 mm wire The range can be extended to 5000 feet 1524 m using 24 AWG 5 0 5 mm wire or 4000 feet 1220 m using 26 AWG 4 0 4 mm wire with the use of a data link protector The protector is an isolating transformer used to remove phantom power on the system side and re introduce it on the terminal side When a protector is used the voice terminal must be locally powered by an external power supply or through the AC power cord provided with some of the 7400 type voice terminals The protector is installed on the equipment side of the protection in both buildings Refer to Example Adjunct Power Connections and Connections at Trunk Auxiliary Field 166 Digital Voice Circuit Protectors Circuit Pack Enhanced Primary Protector With Sneak Current Protection TN754 V13 or earlier ITW Linx Only TN754 V14 or later 4C3S 75 or ITW Linx TN754B all vintages 4C3S 75 or ITW Linx TN2181 all vintages 4C38 75 or ITW Linx TN2224 all vintages 4C38 75 or ITW Linx Refer to Example Adjunct Power Connections and Connections at Trunk Auxiliar Field Example Adjunct
288. ing the cabling 255 1 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the TN802B IP Interface and UUCSS is the cabinet carrier and slot of the TN802B IP Interface Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the customer s gateway and UUCSS is the cabinet carrier and slot of the TN802B IP Interface Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of another computer beyond the gateway and UUCSS is the cabinet carrier and slot of the TN802B IP Interface Return to Task List Installing a TN802B in IP Trunk Mode Return to Task List Note IP Trunk mode should only be used to maintain compatibility with existing Release 7 IP Trunk or ITS E installations We strongly recommend that MedPro mode be used whenever possible Task list Install the TN802B in IP Trunk mode o ON Oo Oi F WO N c o a A N 17 Prepare for Installation Check your Shipment Connect the Cables for TN802B Connect the Modem Connect the Monitor Keyboard and Mouse Connect the Ethernet Install the Circuit Pack Test the Modem Administer the IP Interface Log onto the TN802B Interface Server Change Mu Law to A Law for systems using A Law companding only Assign Server and Domain Names Ass
289. inistration for Network Connectivity for Avaya Communication Manager The TN2302AP IP Media Processor can work with the TN802 IP Trunking and the TN802B IP Interface Assembly When figuring the maximum number of circuit packs you must include all in your total count Each TN2302AP can support between 32 and 64 voice channels depending on the codecs used Note The TN802 IP Trunk cannot talk directly via Ethernet to the TN2302AP IP Media Processor Task List Prepare for Installation and Upgrade Perform these tasks in order 1 Check your onsite equipment 2 Check your shipment Check your onsite equipment Begin Return to Task List Have the following equipment on site before your shipment arrives An unoccupied port slot in the Avaya Media Gateway for each TN2302AP IP Media Processor Note The TN2302AP consumes 16 W of power per slot compared with an average of 15 W per slot Do not fill every available slot in a given carrier with them An additional unoccupied port slot for the TN799x if needed If you have an existing C LAN TN799x circuit pack replace it with the TN799DP or later if it is to be used for IP solutions registration A 10 BaseT or 10 100 BaseT Ethernet connection into your local area network LAN for the TN2302AP A 10 BaseT Ethernet connection into your LAN for the TN799x 234 more valid unused IP addresses on your network one for each TN2302AP or TN802 B and one for each C LAN
290. ion Frame 2 AC Power Cord AC Powered Cabinets Only 3 Cable Slack Manager Number 1 4 Trunk Auxiliary Field 5 Station Distribution Field 6 Cable Slack Manager Number 2 7 Cable Slack Manager Number 3 8 System Cabinet s 9 To Building Cables 10 10 AWG 25 6 mm Wire to Coupled Bonding Conductor Cable Routing to Bottom Terminal Blocks 59 1758432b MMR 052996 Figure Notes 1 Main Distribution Frame 2 AC Power Cord AC Powered Cabinets Only 3 Cable Slack Manager Number 1 4 Trunk Auxiliary Field 5 Station Distribution Field 6 Cable Slack Manager Number 2 7 Cable Slack Manager Number 3 8 System Cabinet s 9 Building Cables Through Cable Trough 10 10 AWG 25 6 mm Wire to Coupled Bonding Conductor Coupled Bonding Conductor The Coupled Bonding Conductor CBC connects to the single point ground block and runs adjacent to pairs in an associated telecommunications cable The mutual coupling between the bonding conductor and the pairs reduces potential differences in terminating equipment The conductor consists of a 10 AWG 25 2 5 mm wire tie wrapped to the inside wiring cable and terminated at the CBC terminal bar at the Main Distribution Frame MDF A minimum of 12 inches 30 48 cm spacing must be maintained between the CBC and other power and ground leads The 10 AWG 25 2 5 mm wire must be long enough to reach the telecommunications cables at th
291. ion about installing the telecommunications cabling and procedures for doing the installation Information about Installing the Cabling Provisioning Plan Main Distribution Frame MDF Hardware MDF Cross Connect Fields Main Distribution Frame Main Distribution Frame Labels Off Premises Circuit Protection Cable Installation Sneak Fuse Panels Coupled Bonding Conductor Installation Space Requirements for the sneak fuse panels the 110 type hardware and the Cable Slack Manager Station Wiring Design Station Circuit Distribution from Equipment Room Layout Patch Cord Jumper Installation and Administration Task List Installing the Telecommunications Cabling 0 5 Q N c 9 10 Label Control Carrier Cable Connect Control Carrier Outputs Cable Connect Trunk Pairs Using Concentrator Cables Connect Trunk Pairs to Cabinet Using Jumper Wires To Establish 3 Pair Modularity Install Cables Between Cabinet and MDF Install Connector Cables Between Auxiliary Cabinet and MDF Mount 110A or 110P type terminal blocks on the wall or Mount 110P type terminal blocks on a frame Install Cable Slack Managers Install Sneak Fuse Panels Install Coupled Bonding Conductor Provisioning Plan A provisioning plan should be completed prior to an installation The plan determines an appropriate available port circuit on the Avaya Media Gateway for each telephone trunk 49 and peripheral connection needed and any auxiliary po
292. ion field to y and submit the form Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 preserve license or reset system 3 no preserve license since the License File has been saved in translations and press Enter Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 3 and press Enter Wait until the system has completely reset before continuing If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints Type set time and press Enter Ensure that the system date and time are set correctly Use one of these installation methods Direct connection between the switch and RFA 217 New or upgraded G3si only No connection between the switch and RFA 1 Retrieve the RFA License File with both serial numbers from the RFA Application 2 If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints 3 Type set time and press Enter Ensure that the system date and time are set correctly 4 For duplicated systems o
293. ire in the system required by UL In this example 1 AWG is used 1 At the DC Power Cabinet connect a 1 AWG 70 44 mm ground wire to the Ground Discharge Bar See Typical Power and Ground for a DC Powered Cabinet 2 Route the ground wire out of the cabinet and terminate it on the approved ground The approved ground must be identified with a grounding tag FORM 15657NR or equivalent See Approved Grounds Return to Task List Connect AC Power to DC Power Cabinet Begin Return to Task List This procedure applies to both the Processor Port Networks PPN and Expansion Port Networks EPN A CAUTION Power is present in the cabinet even if the AC power cable is unplugged Turn off the main circuit breaker on the front of the cabinet when procedures require ALL power to be removed from the cabinet 37 1 Ensure the associated circuit breakers at the AC power panel are OFF 2 Have an electrician connect AC power leads to the rectifiers using the instructions provided with the rectifiers in the DC Power Cabinet Each rectifier should have its own branch circuit Terminate leads on the AC INPUT terminal block of each rectifier Return to Task List Connect Ground Wires for DC Powered Systems Begin Return to Task List A CAUTION Do not connect any ground wires from an EPN cabinet to another EPN cabinet or to a PPN cabinet All ground wires must be terminated at the single point ground block at the main AC supply
294. is complete and the circuit pack is returned to service the procedure designates the original circuit pack as the timing source Note The target circuit packs are automatically removed from service while the firmware is downloaded to them and automatically returned to service after the download is completed While a circuit pack is removed from service any active calls through that circuit pack are dropped Note An error message asking you to use the command test firmware download means that there was a problem with a previous firmware download Run the test before proceeding Go to Testing firmware download on page 352 A CAUTION Unless the Remove Image File After Successful Download field is set to y the fiplogin and ftppassword remain on the TN799DP or TN799C C LAN and TN2501AP VAL circuit packs either until they are reset or until you type the disable filesystem board UUCSS command 4 Ifthe download is scheduled for later ensure that the download will run as you intend by testing the firmware download Go to Testing firmware download on page 352 You can check the progress of a firmware download with this procedure 350 1 Type status firmware download and press Enter to display the Status Firmware Download screen status firmware download last STATUS FIRMWARE DOWNLOAD Source Board Location 01A04 Firmware Image File Name usdlv22r1 Target Board Code IN464 Suffix GP Firmware Vintage 8 Schedu
295. is designed to be connected to a compatible modular jack that is also compliant It is recommended that repairs be performed by Avaya certified technicians The equipment cannot be used on public coin phone service provided by the telephone company Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information This equipment if it uses a telephone receiver is hearing aid compatible Canadian Department of Communications DOC Interference Information This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment DECLARATIONS OF CONFORMITY United States FCC Part 68 Supplier s Declaration of Conformity SDoC Avaya Inc in the United States of America hereby certifies that the equipment described in this document and bearing a TIA TSB 168 label identification number complies with the FCC s Rules and Regulations 47 CFR Part 68 and the Ad
296. is on see Reset LEDs on Power Distribution Unit See Typical Wiring to a Terminal 2 Mark lead destinations on the label next to each connector Also mark the Unit Number and Connectivity information on the label 193 Typical Wiring to a Terminal Figure Notes 1 Power Supply Kit 2 2 5 5 0 or 8 0 Amp Hour Battery 3 1146B Distribution Unit 4 1145B Power Supply 5 Circuits 1 16 6 Circuits 17 32 7 Port Circuit 8 Main Distribution Frame 9 Modular Cord to Pins 7 and 8 Display Terminal Power 11 AC Input 12 Installer Provided Ground Wire 13 ISDN Display System Protocol Terminal 14 Circuits 1 32 Return to Task List Reset LEDs on Power Distribution Unit Begin Return to Task List A red LED next to any of the 32 power output connectors indicates a short circuit in the building wiring or the terminal equipment To reset the LED 1 Disconnect the terminal equipment from the wall jack 194 2 If the LED goes off the terminal equipment is faulty and must be replaced If the LED is still lit find and repair the short circuit in the building wiring 3 Reconnect the terminal equipment to the wall jack and re test terminal equipment operation Return to Task List 1152A1 Mid Span Power Distribution Unit Begin The 1152A1 Mid Span Power Distribution Unit PDU is an Ethernet power supply that provides power to up to 24
297. isplays the location of the Standby Tone Clock Type set tone clock xx where xx is the Port Network Carrier for the Standby Tone Clock Press Enter If Multi Carrier Cabinet MCC1 type status system cabinet number lt 1 44 gt and press Enter or If Single Carrier Cabinet SCC1 type status system all cabinets and press Enter Verify the duplicated Tone Clock is active using the information displayed on the screen If any problems are indicated check the TDM cables in the associated Expansion Port Network EPN Return to Task List Test Expansion Interface Exchange for Each Expansion Port Network Begin Return to Task List If the system is critical reliability test the expansion interface exchange for each Expansion Port Network EPN 1 A ua If Multi Carrier Cabinet MCC1 type status system cabinet number lt 1 44 gt and press Enter or If Single Carrier Cabinet SCC1 type status system all cabinets and press Enter This displays the standby expansion link See Sample of System Status before Expansion Link is Set Type set expansion link UUCSS where UUCSS is one of the cabinet carrier and port locations of the standby expansion link Verify the bottom of the screen displays Command successfully completed Command If Multi Carrier Cabinet MCC1 type status system cabinet number lt 1 44 gt and press Enter or If Single Carrier Cabinet SCC1 type status system all cabinets and pres
298. istering the Circuit Packs After the equipment is installed including circuit packs the circuit packs must be administered This section provides brief information about Administration Commands e Change Circuit Packs Form e Change Circuit Pack Form Implementation Notes Refer to the Administrator s Guide for Avaya Communication Manager for more information In general e Use the Circuit Packs screen to administer circuit packs to carrier slots The circuit packs must be installed or assigned using the Circuit Packs form before administering voice terminals attendant consoles or trunks Each page represents one carrier in the cabinet shown on the command line All carriers and slots appear even if they are not included in the hardware 92 It is not necessary to fill in the Circuit Packs screen if the circuit packs are installed at the time of administration For initial installation assign circuit packs to slots using the hardware configuration layout record from the factory or Customer Services Organization Do not arbitrarily assign circuit packs to slots For r If the carrier type administered on the Cabinet Administration form does not match the physical hardware question marks may display in the Code fields For si When a circuit pack in a slot differs from what has been administered on the form displays between the Sfx and Name fields For r The number of slot fields displayed represents admi
299. istribution unit Connect the P3 connector to the 1145B 8 Power up the 1145B as described on the label on the side of the unit Expanded Power Distribution Unit 1149 Battery 1146 Distribution Unit 0000000000000000 On Battery Reserve 1145 Power U nit Charging Battery gt Output Power On 0000000000000000 0004_1 PDH 062596 Figure Notes 1 Wall Mounting Plate 2 Second 1146B Power Distribution Unit 3 T Cable H600 347 G7 4 First 1146B Power Distribution Unit 5 1145B Power Unit Return to Task List 192 Power Up and Test the Power Supply Begin Return to Task List The following table describes the meaning of the power supply LEDs when lit LED Color Meaning Green Power Supply is providing power Yellow Battery is charging Red Power Supply is on battery reserve 1 Connect the AC power cord to the power supply and route the cord to an appropriate AC outlet using the clips provided on the unit Note A maximum of four power supplies can be powered from one dedicated 100V 120V 50 60 Hz 20 amp feeder or 200V 240V 50 60 Hz 10 Amp feeder Use only unswitched receptacles 2 Plug the cord into the outlet This powers up the power supply 3 Chec
300. itch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File to your laptop PC 2 Open the License Installation Tool LIT application at your laptop PC 3 Use the LIT instructions to add a switch connection profile to the tool 4 Use the LIT instructions to install the License File on the switch 5 f the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints A CAUTION Return to Task List Administer no license emergency numbers Begin Return to Task List If the system enters a No License mode the switch only processes emergency calls Use this procedure to adminster the emergency numbers for No License mode situations 1 Atthe SAT type change system parameters features and press Return The Feature Related System Parameters screen displays 2 Inthe Emergency Numbers Internal field optional type a valid extension Note This field is intended for campus environments where there is an internal emergency number that people are directed to use instead of 911 Calls to other extensions will not go through This number cannot be a hunt group or ACD number 3 In the Emergency Number External field required type a 21 digit dialpad valid character string that can include trunk access codes The default for this
301. k set boot image 1C07 Image Board Type FW Vintage HW Signature Suffix A Date 09 Timestamp CRC Checksum Active Image Reboot Image M DISPLAY FIRMWARE IMAGE S Jd Image 2 TN2501 TN2501 02 01 02 02 A 13 02 05 06 02 10 30 50 12 42 18 Good Good No Yes No Yes J 7 Ensure that both the Act ive Image and the Reboot Image fields are as you expect 354 Test Telephones and Other Equipment This section describes how to test the telephones and other equipment Perform these tests after the equipment has been wired to the system and after the customer s data for that equipment has been administered The tests are acceptance tests and provide some assurance that the Avaya Media Gateways will perform properly after installation and administration If problems occur or more extensive tests are required refer to the Maintenance for Avaya MultiVantage DEFINITY Server documentation Task List Perform Acceptance Tests Make Test Calls Test 302C Attendant Console Test Selector Console Test External Ringing Test Queue Warning Indicator Test Integrated Announcement Record Announcement Playback Announcement Delete Announcement o ON Oo A25 WO DN e Test Music on Hold Test Emergency Transfer Test Remote Access Interface formerly INADS n OO N Remote Test A Local Test Test Basic Rate Interface BRI Test Duplication Option Proce
302. k AC operation of the 1145B Power Supply by monitoring the LEDs PASS Green and yellow LEDs at front of the unit should be lit together Green means the power supply is providing power Yellow means the battery is being charged After the battery reaches full charge maximum of twenty hours the yellow LED should go out FAIL If either green or yellow LED is not lit after powering up check the connections Test the AC outlet If power is available and the AC power cord and connections are good replace the power unit 4 Disconnect the AC plug on the power supply this activates the DC supply 5 Check DC battery back up operation of the 1145B Power Supply by monitoring the LEDs PASS The red and green LEDs should be lit together Red means the power supply is on battery back up FAIL If either green or red LED is not lit after disconnecting AC power check the connections If the connections are good replace the power unit or batteries 6 Reconnect AC power to the power supply Return to Task List Wire the 1146B Power Distribution Unit Begin Return to Task List Wire endpoints to the1146B while power from the 1145B is on A red LED lights if its associated circuit is connected to shorted wiring or to a shorted terminal 1 Install cross connect jumpers to wire from the unit the label shows polarity to Pins 7 and 8 of the appropriate information outlet Route the wires through the clip provided on the unit If a red LED
303. k Start Shut Down and select Restart the computer or on the TN802 circuit pack Press the recessed reset button on the faceplate see TN802B IP Interface faceplate of the TN802B IP Interface until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min reseat the circuit pack to restart the system or on the SAT c Type busyout board UUCSS and press Enter d Type reset board UUCSS and press Enter e Type release board UUCSS and press Enter Once the system is completely initialized the LCD reads MEDPRO 12 Affix the new TN802B label to the circuit pack 13 Disconnect the monitor keyboard and mouse TN802B IP Interface faceplate 276 fpdfmapd 030899 Figure Notes 1 LCD display 2 Reset button recessed 3 Red board status LED 4 PCMCIA card slot 5 Yellow PCMCIA disk in use LED Return to Task List Verify Circuit Packs Begin Return to Task List 1 Type change circuit pack and press Enter 2 On the Circuit Packs Screen 1 check the Code column to see if it says DSMAPD or MedPro 3 To correct it go to the entry just above the TN802B that says DSMAPD 4 Type MEDPRO and press Enter Changing the one entry automatically changes the entry above it If it is in IP Trunk mode you get the following error message MedPro type requires TN802 with application Type MEDPRO on circuit packs form
304. l The default 6 character field name is amp H1 Set the field name to Q3 for Intel modems This field is not case sensitive Configures modem as an asynchronous device This 8 character field name has a default value of amp MO default for R10 SCC Set the field to amp MO0 amp QO for Intel modems This field is not case sensitive Adjusts the speed of the data source DTE UART to the outgoing modem to modem data rate At maximum this speed is 9600 baud It is not desirable to have the serial data fill the modem buffer faster than the outgoing data rate since data compression is disabled The field name has a 6 character blank default value The Paradyne products use S90 1 to enable this functionality while the Intel product uses M1 to enable similar functionality This field is not case sensitive Turns off the default data compression algorithms used by most modems The field has a blank field of 6 characters as default The AT commands that control this are supported by similar commands however these commands do not operate in the same manner The Intel modems require HO CO to disable V 42bis amp MNP Class 5 data compression algorithms The Paradyne products only to disable both algorithms This field is not case sensitive Turns on the V 42 LAPM and MNP error control protocols The field has a blank default of 6 characters The Paradyne products use the command 5 to enable V 42 MNP Buffer error control while the In
305. l Tone n 440Hz Secondary dial Tone n Digital Loss Plan 1 Analog Ringing Cadence 1 Set Layer 1 timer T1 to 30 seconds n Analog Line Transmission 1 _ Enhanced 84xx Display Character Set y TONE DETECTION PARAMETERS Tone Detection Mode 6 Interdigit Pause short Return to Task List Change the Password Begin Return to Task List Change the password for the craft login to prevent unauthorized administration changes Note If you are using a dadmin login and password you can skip this procedure or change the dadmin password if you want A CAUTION After changing the password safeguard the new password so no unauthorized administration changes can be made DO NOT REVEAL this password to any unauthorized person Passwords are changed using the PASSWORD ADMINISTRATION screen See Typical Change Password Screen 1 Verify the screen displays command 2 Type change password craft and press Enter 114 3 Verify the screen displays the PASSWORD ADMINISTRATION screen The cursor is positioned on Password of Login Making Change 4 Type the craft default password and press Enter The cursor is positioned on Login s Password 5 Enter new password Valid passwords consist of a combination of from 4 to 11 alphanumeric characters At least one letter and one digit must be used in each password Press Enter The cursor is positioned on Reenter Login s Password Type new password again and press Enter
306. l and Administer ISDN BRI Return to Task List Note Adding ISDN BRI requires a service interruption when you add packet bus support and you install TN570s as part of that support Give the customer advance notice of the scheduled addition See Add Packet Bus Support for further information See BRI Terminating Resistor Installation for an important warning details on the resistors adapters and multipoint installation distances Task List Installing ISDN BRI Perform these tasks to install and administer ISDN BRI 1 Add Circuit Packs ISDN BRI 2 Install Cables ISDN BRI 3 Enter Added Translations ISDN BRI 4 Resolve Alarms 5 Save Translations ISDN BRI BRI Terminating Resistor Installation The resistors balance the cable plant between the receiver and the transmitter on the interface When using the TN2198 ISDN BRI 2 Wire U Interface circuit pack an NT1 is required A terminating resistor is always required near the terminal when the BRI S type interface circuit pack TN556 BRI 4 Wire S NT Line circuit pack is used see 5ESS Switch Integrated Services Digital Network Customer Premises Planning Guide The resistor is built into the NT1 and can be one of three values depending on the configuration and the distance from the NT1 to the ISDN terminal The resistor value is controlled from the NT1 A terminating resistor adapter may be needed near the terminal and can be placed in the satellite closet or work locatio
307. lation methods Direct connection between the switch and RFA No connection between the switch and RFA Retrieve the RFA License File with both serial numbers from the RFA Application 303 2 If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints 3 Type set time and press Enter Ensure that the system date and time are set correctly 4 For duplicated systems only type status system all and press Enter Ensure that the standby SPE is notin the maintenance state If it is wait for the maintenance state to finish 5 Use one of these installation methods Direct connection between the switch and RFA No connection between the switch and REA Direct connection between the switch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File Note This procedure sends the License File to the switch and installs it 2 f the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints No connection between the switch and RFA 1 Goto the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File to your laptop PC 2 Open the License Installation Tool LIT
308. le 385 hardware MDF 50 Hong Kong country code 113 hybrid line pinouts 415 I I O cables 84 ICSU 279 cable guidelines 279 required components 279 impedance setting 380 INADS 159 register system 121 testing 358 information outlets wiring design 61 Initialization and Administration System See INADS installation additional port circuit packs 199 modems 325 installing auxiliary cabinet 20 installing auxiliary cabinet equipment 20 installing cable slack manager 84 installing cables 56 installing cables between auxiliary cabinet and MDF 79 installing cables between cabinet and MDF 78 installing coupled bonding conductor wires 36 installing earthquake protection MCC 21 22 installing EPN cabinet 19 installing fiber optic cable 45 critical reliability CSS system 47 high reliability CSS system 46 MCCI 391 standard reliability CSS system 45 installing fiber optic cable MCCI 395 installing patch cords and jumpers 72 installing PPN cabinet 19 installing sneak fuse panels 85 installing system access software 91 95 installing the MDF 53 installing trunk cables 58 integrated announcement testing 357 integrated channel service unit 279 integration process connecting ITS components 249 259 connecting ITS to the network 237 internet telephony server See ITS IP address assigning 265 IP connections testing 271 IP gateway assigning 267 IP interface administering Media Processo
309. le Assembly 9 9 9 9 cbdfocto AWF 122398 Figure Notes 1 Amphenol connector to connector corresponding to TN802B slot 2 To VGA monitor 3 To USB not used 4 To keyboard 5 To mouse 6 To ethernet 7 25 pin male connector to modem 8 25 pin male connector to COM2 not used Return to Task List Connect the Cables for TN802B Begin Return to Task List 1 Determine into which port slot you are putting the TN802B IP Interface 258 Note Make sure that at least 3 adjoining slots are free 2 From the rear of the cabinet connect the amphenol connector on the external cable assembly to the backplane connector corresponding to that slot the highest numbered connector of the 3 slots required Connect the Modem Begin Return to Task List Note These instructions are for connecting the U S Robotics modem supplied to U S customers only If using a different modem follow the manufacturer s instructions on connecting the modem 1 Connect the RS232 port of the modem to the MODEM connector of the TN802B external cable assembly Note Check the labels near the connectors the MODEM and COM connectors look the same 2 Connect an analog telephone line to the left most analog line port on the modem as shown in External Modem Connections for U S Robotics Modem 3 Make sure that the modem s DIP switches are set as shown in External Modem Connections for U S Robotics Modem a
310. le Download y Remove Image File After Successful Download y Start Date Time 10 08 2002 22 00 Stop Date Time 10 08 2002 22 02 x Target Target Target Target Target Location St Location St Location St Location St Location St 1 01B04 C 11 21 3T 41 2 O1BO5 C 12 224 32 42 Sus 13 23 334 43 4 14 24 34 44 5 1545 255 355 45 6 16 26 36 46 7 TT 21 315 47 8 18 28 38 48 95 19 29 39 49 10 20 30 40 50 Status Pending P Completed C Failed F Aborted P If this form is blank the download has completed go to Step 3 N Check the st status field immediately to the right of the Target Location field to view the progress of the firmware update P ending C ompleted F ailed A borted Type status firmware download last and press Enter to view the progress of the last completed firmware update or the entire schedule if it is completed Notice in the previous screen that the Start and Stop times now reflect the actual start and stop times of the download schedule and that the Firmware Vintage now reflects the vintage that was downloaded A If one or more downloads fail go to Testing firmware download on page 352 If previously you set the Remove Image File After Successful Download field on the Firmware Download screen to y then the download procedure is now complete If you previously set it to n then proceed to the next section Disable file s
311. ling 33 signaling leads 378 DC power cabinet 37 approved ground 37 connecting AC power 37 DC AC mixed ground and power 40 DCE mode setting data module 101 DC powered system power up 105 DCS switch settings 365 DCS interface adding 224 225 226 227 229 DCS switches setting 367 DEFINITY ECS connecting the PC 97 98 99 DEFINITY ECS connecting through a data module 98 DEFINITY ECS connecting through a modem 99 DEFINITY ECS system testing 362 DID trunk wiring 143 DID trunk adding 296 DID trunks 296 DID DIOD pinouts 417 digital line circuit pack 98 digital line circuit protectors 165 digital tie trunk wiring 146 DIP switch locations data module 365 DIP switch settings 7400B data module 102 DIP switch settings U S Robotics modem 99 direct connect systems 44 direct department calling testing queue warning indicator 357 direct PC connection to DEFINITY ECS 97 Index distributed communications system See DCS D lead modem 369 domain name assigning 264 DS1 converter 411 412 413 cabling 305 circuit pack LEDs 126 duplicated 410 E1 308 309 310 311 315 316 option switches 305 T1 308 309 310 311 315 316 Y cable 311 DS1 H600 307 cable pinouts 424 DS1 interface 380 DSI pinouts 417 DS1 tie trunks 298 299 300 301 302 DS1 tie trunks wiring 146 DSI1C converter 407 duplicated SPE interchange testing 133 duplicated systems 119 duplication interface cabling MCC
312. ll install Fuse Panel pi o eres Install Coupled Bonding Conductor Bring the System Online About Accessing the System PER Administration Scree d Commands POPE ee Change Circuit Paris Font GM 9 M 93 Change Pa Pam Implementation Notes dXX ved Pinos Up AUDIX pun NEMORE OMEN E Annett the odule 98 136 in Translations if B N E TOE 77 Install and Wire Telephones 139 Voice and Data Terminals 139 oice a 140 ir rund Four an a junct Power niri Install the Y W ng Indicator Install and Wire Power 183 1145B Power Supply bee eee UE Important Warning for 11458 Power Supply fhe ee Bec Se Ben tee Bt Gea qe D Install the Wall Mounting A REX Ades GOSS Ae xi Mount the 1146B Power Dist buien Unit nee nes iren the 1151A2 DOE 197 Install 199 rt C cuit Packe ie oh ns Oe Ee ee Ro ee AL ee ed 200 and Auxiliary Equipment Classifications 200 installing Circuit t ERRARE RS abies and Am linister ISDN ode WR ee RG Bee Bes ares Add Packet Bue Support uuu an cx RRR MRR HEN dO X3 T T 464 P TI N2464BP with Echo arcis Adminis
313. lly A Law for Europe and mu Law for North America and Japan If necessary type change terminal parameters and press Enter to change the default system level parameters and audio levels for these terminals 4 Administer other forms for Attendant Console refer to the Administrator s Guide for Avaya Communication Manager for more information Return to Task List Save Translations Avaya DEFINITY Server si Begin Return to Task List This command copies the current system translations onto the translation card or removable media For Standard Reliability systems one translation card plus one backup is required For High or Critical Reliability systems two translation cards plus two backups are required A CAUTION Do not attempt to save translations on the orange labeled generic program card Use the white translation card 119 The following procedure can be used to save system translations on the original card s and can also can be used to make a backup card or cards 1 Type save translation and press Enter 2 Verify a 0 is displayed in the Error Code column for each Switch Processing Element SPE A 0 indicates the save translation was successfully completed If a 0 did not appear the save translation did not complete Record the error code number and the error message and notify your Avaya representative 3 Remove the original translation card from the processor circuit pack and replace it with the backup card
314. log Line 24 2 wire R10 T11 R11 T12 R12 T13 R13 T14 R14 T15 R15 T16 R16 T17 R17 T18 R18 T19 R19 T20 R20 T21 R21 T22 R22 T23 R23 T24 R24 Hybrid AUX Line Trunk VIRA R4 CT4 SZ4 CR4 5214 P 4 S4 4 S14 V1T5 V1R5 CT4 CR4 P 5 P 5 V1T6 V1R6 CT6 CR6 P 6 P 6 V1T7 V1R7 CT7 CR7 P 7 P 7 V1T8 V1R8 CT8 CR8 P 8 P 8 co Trunk R4 5 R5 T6 R6 7 R7 T8 R8 The wire colors in this chart apply only to B25A and A25B cables H600 307 cable colors are not shown 416 The following wire colors apply to this chart White S Slate Grey BL Blue R Red O Orange BK Black G Green Y Yellow BR Brown V Violet The following abbreviations apply for all circuit packs unless otherwise noted T R PBX transmit voice Tip A Green T1 R1 PBX receive voice R Ring B Red M PBX transmit signal S Sleeve E PBX receive signal PX PBX transmit TX Terminal transmit LI LI Digital Trunk IN LO LO Digital Trunk OUT Circuit Pack and Auxiliary Equipment Leads Pinout Charts Begin Color Con co DID Tie DS1 ISDN ISDN Packet 4Port nector Trunk DIOD Trunk Tie BRI BRI Data DIOD Pin Nos 3 wire Trunk Trunk Line Line Line 4 wire 2 wire W BL 26 A1 T1 T1 PXR1 T1 TXT1 T1 BL W 01 B1 R1 R1 PXT1 R1 TXR1 R1 W O 27 T11 TXT1 T2 PXT1 O W 02 R11 TXR1 R2 PXR1 W G 28 E1 PXR2 T3 TXT2 G W 03 C1 M1 PXT2 R3 TXR2 W BR 29 A2 T2 T2 TXT2 T4 PXT2 T2 BR W 04 B2 R2 R2 TXR2 R4 PXR2 R
315. lugged When procedures require ALL power to be removed from the cabinet and to prevent unnecessary discharging of the battery turn off the main circuit breaker located on the front of the power distribution unit 2 Be sure the main power to the power distribution unit is OFF 3 At the power distribution unit set all carrier circuit breakers OFF Typical Small Battery Assembly Battery connector psdfbatb RPY 061797 Return to Task List 28 Connect Small Battery Holdover Begin Return to Task List Connect the small battery holdover cable to J20 See Power Distribution Unit J58890CH Power Distribution Unit J58890CH pedf010 020599 Figure Notes 1 Connect small battery holdover cable or temperature sensor cable from large battery cabinet to J20 2 Carrier Circuit Breakers 3 Ground Terminal Block 4 Connect 48 VDC Return 1 AWG 50 mm red cable here 5 Connect 48 VDC 1 AWG 50 mm black cable 6 1 AWG 50 mm 50 ft 15 2 m cable to large battery cabinet For cables greater than 50 ft 15 2 m contact your Avaya representative 7 Ground Terminal Block 8 To AC load center or approved single point ground block Return to Task List Connect Large Battery Holdover Begin Return to Task List When using large battery holdover 1 battery cabinet is required for every system cabinet requiring holdover The 24 cell battery cabinet must have a float voltage of 5
316. ly Non U S customers must provide a modem comparable to this model 20 ft DB 25 serial cable from modem to TN802B 1 external cable assembly U S customers only Non U S customers must provide a serial cable 1 One TN799x supports more than one TN802B TN802B IP Interface External Cable Assembly 9 9 9 9 cbdfocto AWF 122398 Figure Notes 1 Amphenol connector to connector corresponding to TN802B slot 2 To VGA monitor 3 To USB not used 4 To keyboard 5 To mouse 6 To ethernet 7 25 pin male connector to modem 8 25 pin male connector to COM not used Return to Task List Connect the Cables for TN799x Begin Return to Task List 248 1 Determine into which port slots you are putting the TN799x C LAN circuit packs From the rear of the cabinet 2 Connect the 259A connector to the backplane connector corresponding to the TN799x slot 3 Connect one end of the CAT5 cable to the 259A connector Connect the other end to the customer s network Connect the Cables for TN802B Begin Return to Task List 1 Determine into which port slot you are putting the TN802B IP Interface Note Make sure that at least 3 adjoining slots are free 2 From the rear of the cabinet connect the amphenol connector on the external cable assembly to the backplane connector corresponding to that slot the highest numbered connector of the 3 slots required Connect the Modem
317. m this slot Install the new circuit pack From the front remove the fan cover See Remove the Fan Cover Open the rear door Attach the panel adapter bracket See Attach the Panel Adapter Bracket Insert the cable assembly See Attach the Cable Assembly to the Bracket Connect the external modem cable to the cable assembly Attach the RJ45 telephone plug to the pass thru tool using a tie wrap See Attach the Cable to the Pass Thru Tool If you are using only one RJ45 bundle the other one and tie wrap it near the body of the cable assembly Slide the tool to the front of the cabinet See Insert the Pass thru Tool Pull the tool with adapter and cable attached out through the front of the cabinet Close the rear door Replace the fan cover See Replace the Fan Cover Connect the cable to the front of the TN1648B circuit pack See Connect the Cable to the TN1648B Circuit Pack Dress the cable straight down the front of the circuit pack Do not allow the cable to cross in front of another circuit pack Attach the cable mount to the cabinet and secure the cable See Connect the Cable to the TN1648B Circuit Pack Close the front door Discard the pass thru tool Log in as craft 330 Note If you have a dadmin login and password you can use them instead of craft and the craft password 21 Administer the system by referring to the nstallation for Adjuncts and Peripherals for Avaya MultiVantage Solutions 22 Type li
318. may be more text in the description field if other resolved alarms were reported 5 Have the remote personnel make second call and log into the system and check the error log to verify no problems See Maintenance for Avaya MultiVantage DEFINITY Server documentation for your system for error log and error code information 6 Have the remote access personnel terminate logoff and disconnect 358 Return to Task List Local Test Begin Return to Task List 1 Log in as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 2 Type test inads link and press Enter 3 Request remote access personnel to verify that a trouble ticket was created 4 Check error log to verify no problems 5 Log off the system Test Basic Rate Interface Begin Return to Task List Check for normal voice telephone function dial tone ability to make and receive calls Check for the correct Service Profile Identifier SPID on a display telephone and the management terminal Test Duplication Option Processing Element Interchange Begin Return to Task List The process of the standby Processing Element PE taking over for the active PE is referred to as a PE Interchange This interchange should not be performed immediately after powering up the system Wait a few minutes to allow the system to complete its internal tests The system default is PE B after powering up the system so the ac
319. mes ip and press Return The IP Node Names screen appears Use this screen to administer the circuit pack s node name Type a unique name in the Name field This name is recognized only within the switch and does not need to match the node name on your network Enter the IP Address You can get this information from the network manager Press Enter to save the changes Type change ip interfaces and press Return The IP Interfaces screen appears Use this screen to administer an IP interface which associates the circuit pack with an IP address Set the Enable Eth Pt field to y Set the Type field to VAL Type the circuit pack location in the Slot field UUCSS If a TN2501AP circuit pack is not at this location when you submit the screen the system prompts you to enter a VAL circuit pack location In the Node Name field enter the Node Name you entered in step 4 If you press Help a list of administered node names appears including the name you administered with the change node names ip command and you can select from the list Set the Subnet Mask field according to your network requirements 211 Gateway Address is usually the same as the TN2501AP circuit pack s IP address usually with the fourth octet changed Be sure to set this address according to your network requirements 13 Press Enter to save the changes 14 Type add data module extension and press RETURN The Data Module screen appears Use this scree
320. meter reads 0 VAC If not have a qualified electrician correct the problem 6 Set all cabinet power modules OFF Plug the AC power cable into the receptacle Return to Task List Verify Fiber Optic Duplication Interface Cabling TN792 port networks Begin Return to Task List If the fiber optic duplicate interface cabling is not already installed interconnect the A and B port networks TN792 with the 14 in fiber optic cable see Fiber optic cable connecting the two duplication interface circuit packs Fiber optic cable connecting the two duplication interface circuit packs 43 fodf792 090399 Figure Notes 1 AHF110 TDM Bus Terminator Slot 17 2 TDM Local Area Network TDM LAN Pinfield Slot 00 3 TDM Bus Cable WP 91716 L3 4 Port Cabinet Standard Reliability 5 Control Cabinet A Position 6 AHF110 TDM Bus Terminator Slot 03 7 Slot 18 Return to Task List Connect Fiber Optic Interconnect Cabling Return to Task List Signals between the cabinets are carried by fiber optic cables Lightwave transceivers provide the required fiber optic interface The fiber optic cables from the DEFINITY ECS route to a Lightguide Interconn
321. minals Data BCTs and Business Communications Systems BCS 510D BCT 513 BCT 515 BCT 615 BCT 715 BCT 715 BCS PC PBX platform digital PC ISDN platform BRI Consoles Data and 301A Attendant Console 302A1 Enhanced Generic 1 voice Console 602A1 ACD Console CallMaster digital communications terminal ZE01A Expansion Module for 8434Dx Voice and Features Cordless Hybrid Voice MDW 9000 TransTalk 9000 MDC 900 DCP Data interface Data and Constellation Automatic Call Distribution ACD data voice terminal PassageWay interface Data and Consoles voice 302B1 302C1 Attendant Console 603A D Automatic Call Distribution ACD Console CallMaster digital console 603E Automatic Call Distribution ACD Console CallMaster digital console Connectable Administration Terminals These administration terminals can connect to a Avaya Media Gateway Administration Terminals Administration Terminal Application 510D Remote administration 610D 513 610 615 715 Management Terminal administration and Business Communications general purpose Terminal BCT 4410 4425 and VT220 515 Business Communications Remote administration general purpose Terminal BCT 615 Management Terminal Management Terminal system administration and maintenance terminal 715 BCS and 715 BCS 2 Management Terminal system administration Management Terminal and maintenance terminal The keyboards and terminals are interchangea
322. ministrative Council on Terminal Attachments ACTA adopted technical criteria Avaya further asserts that Avaya handset equipped terminal equipment described in this document complies with Paragraph 68 316 of the FCC Rules and Regulations defining Hearing Aid Compatibility and is deemed compatible with hearing aids Copies of SDoCs signed by the Responsible Party in the U S can be obtained by contacting your local sales representative and are available on the following Web site http www avaya com support All Avaya media servers and media gateways are compliant with FCC Part 68 but many have been registered with the FCC before the SDoC process was available A list of all Avaya registered products may be found at http www part68 org by conducting a search using Avaya as manufacturer European Union Declarations of Conformity CE Avaya Inc declares that the equipment specified in this document bearing the CE Conformit Europe nne mark conforms to the European Union Radio and Telecommunications Terminal Equipment Directive 1999 5 EC including the Electromagnetic Compatibility Directive 89 336 EEC and Low Voltage Directive 73 23 EEC This equipment has been certified to meet CTR3 Basic Rate Interface BRI and CTR4 Primary Rate Interface PRI and subsets thereof in CTR12 and CTR13 as applicable Copies of these Declarations of Conformity DoCs can be obtained by contacting your local sales represe
323. module and reconnect the data module to the system cabling Return to Task List Set the 7400B Data Module Options Begin Return to Task List 102 1 Set the DIP switches for the 7400B using DIP Switch Settings 7400B The DIP switches are located inside the unit To access them remove the power cord from the unit remove the cover from the top rear of the unit set the dip switches replace the cover and connect the power cord The unit performs a self test 2 f any switches were set in step 1 cycle the power to the data module so that the firmware can read the new switch settings DIP Switch Settings 7400B Option DIP Switch Setting No Telephone Connected 1 On Data Metering 5 Off Suppress Touch tone Dial Tone 6 Off Speakerphone Disable Enable T Off Busyout on Local Loop 8 Off Unused DIP Switches 2 3 and 4 Off Return to Task List Activate the System Return to Task List Note To prevent unnecessary trouble tickets do not enable the system alarms Alarm Origination feature until all installation and administration procedures are completed A CAUTION It may be necessary to reseat circuit packs To prevent damage from static electricity always wear an Electromagnetic Compatibility EMC wrist strap when handling all system components Task List Activate the System Return to Task List 1 Install Translation Flash Memory Card Avaya DEFINITY Server si or Install Removable Media MCC1 only
324. must be either UL listed CSA certified or must comply with local safety standards Sneak current protectors must have a maximum rating of 350 mA and a minimum voltage rating of 600 V or as required by local regulations The following devices protect the system from over voltages e Analog trunks use the 507B sneak protector or equivalent Over voltage protection is normally provided by the local telephone company e Analog voice terminals use one of the following types of combined over voltage and sneak current protection or equivalent 55 Carbon block with heat coil for UL code 4B1C Gas tube with heat coil for UL code 4B1E W Solid state with heat coil for UL code 4C1S DCP and ISDN BRI terminals use the solid state 4C3S 75 with heat coil protector or equivalent e DS1 E1 T1 circuits require isolation from exposed facilities This isolation may be provided by a CSU T1 LIU E1 or other equipment that provides equivalent protection Sneak Fuse Panels Sneak current protection is required between the incoming RJ21X or RJ2GX network interface and the system for both trunk and off premise circuit packs The Model 507B sneak current fuse panel or equivalent is recommended for sneak current protection The panel contains two 25 pair connectors fuse removal tool and fifty 220029 sneak fuses and two spares Connector cables B25A male to female connect the network interface to the sneak fuse panel Also 157B connecting
325. must be suitable for transmission of digital data If Customer Premises Equipment that alters digital data exists on this facility such as with a channel expansion multiplexer enter no Line Coding Enter the line coding format ami zcs default or ami basic b8zs or hdb3 in the A B C and D columns under the DS1 Converter Facilities heading for each DS1 facility When ami zcs line coding is used all zero bytes are prevented from being transmitted on the DS1 facility because a 1 is arbitrarily written into the second position of each byte Thus if no measures are taken to prevent it ami zcs line coding results in data corruption The DS1CONV circuit pack protects the packet facility one of up to four facilities dynamically allocated by the DS1CONV circuit pack from corruption through a special escape mechanism When b8zs line coding is used it maintains DS1 facility s ones density requirements by encoding a zero data byte into a specific unique pattern of bipolar violations on the DS1 line The opposite end recognizes this pattern and replaces it with a zero data byte when the data is recovered at the receiving end Note Note that although the esf framing mode and b8zs line coding are the preferable modes of operation you should confirm that the DS1 facilities support them before selecting this line coding Framing Mode Enter the framing format esf default or d4 in the A B and D columns under the DS1 Con
326. n Note The 440A4 terminating resistor and 110RA1 12 terminating resistor block are UL listed Most new installations are the 110RA1 12 terminating resistor block See these BRI terminating resistor topics Important Warning for Telephone Wiring Terminating Resistor Adapter and Block Installing Multipoint Adapters Basic Multipoint Installation Distances 203 Important Warning for Telephone Wiring Begin Observe these precautions Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines Terminating Resistor Adapter and Block Begin 8 Wide Terminating Resistor Adapter 440A4 shows an 8 pin 440A4 terminating resistor adapter The adapter is three inches long with an 8 wide plug at one end a short cord and an 8 wide jack at the opposite end The 110RA1 12 terminating resistor block is designed to mount in the telecommunications wire closet It consists of twelve 2 pair circuits and provides the 100 Ohm termination used for ISDN BRI circuits Terminating Resistor Block 110RA1 12 shows the wiring of the 110RA1 12 Three rows of 110D 4 connector blocks are mounted on a printed wire board along with circuit resistors and capa
327. n country code 114 SPAN LEDs 127 SPE duplication memory shadowing testing 133 SPE interchange testing 133 speech synthesis adding 216 standards electromagnetic compatibility 3 standby components LEDs 127 start up messages 105 station cables sizing 71 station cables wiring design 61 station circuit distribution 65 storage media removable media 104 translation card 103 Stratum 3 clock 317 cabling 320 checking AC power 318 connecting to DC power 318 319 cross connects high or critical reliability 322 standard reliability 322 grounding cabinet 318 installing 317 LED indicators 361 maximum cabling distance 322 setting options 319 testing LED indicators 361 wiring 322 Stratum 3 clock administering 362 Stratum 3 clock connecting AC power 318 Stratum 3 clock inspecting 317 Stratum 3 clock testing 361 Stratum 3 clock timing 362 switch settings 365 572 printer 371 7400A and 7400B data modules 338 7400A data module 369 7400D data module 368 CDR 374 data module 365 AUDIX 377 DCS 365 external modem 326 370 TN2464 circuit pack 380 TN464 circuit pack 380 TN760 tie trunk 378 system access 91 system access testing 358 system printer 371 system start up messages 105 system status checking 129 system test alarms 362 system testing 362 sytem tests 125 T T1 CSU and DS1 tie trunk 146 1 1 status LEDs 127 TDM bus 380 service state 129 TDM testing 131 13
328. n Avaya Media Gateway r in a Multicarrier Cabinet MCC1 When a fiber optic cable is properly labeled it is easy to trace the desired circuit by looking at the labels on the cross connect the cable itself and the individual fibers in the cable Refer to Fiber Link Administration Form Administration commands PN reliability configurations Task List Administration Details Fiber Link Administration Form This form administers fiber links each of which is identified by a fiber number Port networks PNs are connected via direct fiber link connections or through a center stage switch CSS to provide the interconnection of port networks required for voice data information transfer The CSS is composed of switch nodes that can be interconnected in one or two levels to provide Port Network Connectivity PNC The CSS provides circuit switched connectivity for voice and data communications as well as packet switched connectivity Fiber link administration permits an administration of translation data associated with a switch connection such as optical fiber metallic cable or DS1CONV circuit packs and DS1 facility links between two endpoints The two fiber endpoints can be expansion interface El circuit pack A switch node interface SNI circuit pack Note Only one administrative terminal can administer fiber links at a time others can display fiber link information Administration commands Use the
329. n be rack mounted using standard rack mounting brackets See 1145B 1146B Mounting Arrangement 1 Locate one plate directly below the other one such that the AC power cord 6 5 feet or 2 meters reaches the electrical outlet from a power supply mounted on the bottom plate Both plates should be located so the raised letters are right side up Note A maximum of four power supplies can be powered from one dedicated 110 VAC 20 amp or 230 VAC 15 amp feeder Use only unswitched receptacles receptacles not connected to a wall switch 2 Secure the wall mounting plates to a standard 3 4 inch 2 cm thick plywood mounting board Each mounting plate comes with four 10 x 1 2 inch wood screws 3 The 1145B Power Supply is snap fit onto the bottom wall mounting plate without tools 4 An installer provided insulated ground wire 16 AWG 12 1 2 or greater is required to connect the power supply frame ground lug to an approved ground The frame ground screw is located next to the AC receptacle to the left of the unit 5 Mark the Unit Number and Connectivity information on the front label next to the LEDs 188 1145B 1146B Mounting Arrangement 1149 Battery Ed 1 On Battery Reserve o o 1145 Power Unit Charging Battery
330. n of the Remote Power Off RPO cable The opposite end of the cable connects to the Emergency Power Off EPO switch located outside of the equipment room Even though the equipment room EPO switch disconnects main AC power to the equipment room it cannot disconnect the battery power from the J58890CH An auxiliary set of contacts inside the EPO are used for this function 1 Plug the RPO cable into the connector shown in Remote Power Off Cable Connections Part 1 2 Route the opposite end of the wires to the EPO switch The opposite end of the RPO cable connects to the internal relay Note The EPO switch and the auxiliary contacts inside the EPO switch assembly are customer provided A CAUTION The auxiliary contacts inside the EPO switch assembly must close when the switch is pressed This contact closure energizes the relay inside the power distribution unit causing the connection to the battery holdover assembly to open Remote Power Off Cable Connections Part 2 shows the cabling from the auxiliary contacts inside the EPO switch assembly and how they connect to the internal relay 3 Connect the RPO wires to the auxiliary contacts on the EPO switch See Remote Power Off Cable Connections Part 2 Note The EPO switch and the auxiliary contacts for the RPO connection are customer supplied 41 Remote Power Off Cable Connections Part 1 Carrier circuit breakers Connect RPO cable here
331. n of the management terminal Refer to the Administrator s Guide for Avaya Communication Manager for more details Analog Tie Trunk Wiring 9 9 26 29 T2 R1 14 amp 0 4 R2 1 1 274 gt gt 30 1 2 R1 1 24 0 5 H12 E 1 28 lt lt 0 31 E2 1 3 lt lt 0 6 M2 tie wire RBP 071796 Figure Notes 1 External Trunk or Adapter 145 2 Tie Trunk Circuit Pack Position 1C05 Return to Task List Digital Tie Trunk Example Return to Task List This example shows how to connect digital tie trunk wiring from one DEFINITY System to another DEFINITY System Digital Tie Trunk Wiring shows the connections 1 Install cross connect jumpers to connect the pins from the digital trunk circuit pack to appropriate pins on the manufacturer s or supplier s external digital trunk 2 Set option switches on the port circuit pack Digital Trunk Go to Option Switch Settings for detailed information 3 Administer on the DS1 and Trunk Group Screens of the management terminal Refer to the Administrator s Guide for Avaya Communication Manager for more details Digital Tie Trunk Wiring 9 lt gt lt gt gt 22 4 lt gt gt 47 dig_tie RBP 040596 Figure Notes 1 External Trunk 2 Digital Trunk Circuit Pack Position 1C06 3 LO 4 LO Balanced Output Pair 5 LI 6 LI Balanced Input Pair Return to Task
332. n the system tests 3 Note any boards with a VINTAGE column entry of NO BOARD or CONFLICT Note u indicates unassigned ports and a number indicates the port has been translated Sample System Configuration Screen Page 1 list configuration all Page T SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u unassigned t tti p psa 01A01 EXPANSION INTRFC TN570B 000001 01A03 DID TRUNK TN459 000004 u u u u u u u u 01A04 DID TRUNK TN436 000004 u u u u u u u u 01A07 TIE TRUNK TN439 000004 u u u u 01A09 ANNOUNCEMENT TN750 000007 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 01B01 EXPANSION INTRFC TN570 000009 01B02 TONE DETECTOR TN748D 000002 01 02 03 05 06 07 01B03 DATA LINE TN726 000012 u u u u u u u u 01B08 BRI LINE TN556B 000003 u u u u u u u u u u u u u u u u u u u u u u u u 01C01 ANALOG LINE TN746B 000006 u u u u u u u u u u u u u u u u press CANCEL to quit press NEXT PAGE to continue S M Return to Task List Test Time Division Multiplexing Bus in Processor Port Network Begin Return to Task List 1 Type test tdm port network 1 and press Enter 2 Verify the screen displays the results of this test See Sample Test Results for TDM Bus Port Network 1 131 3 If the result is FAIL for any test check the connectors of the TDM bus cables in Processor Port Network PPN 1 Sample Test Results for TDM Bus Port Network 1 fast tdm port network 1 TEST RESULTS Port
333. n to Task List Modem Pooling supports 2 types of conversion resources integrated and combined The integrated type requires a TN758 Pooled Modem circuit pack for each 2 conversion resources provided The combined type requires a port on a TN754B Digital Line circuit pack and a port on either an 8 port TN742 TN769 a 16 port TN746B or a 24 port TN793 B TN2793 B Analog Line circuit pack for each conversion resource provided The pooled modem requires a WP90110 L7 power supply Although an integrated conversion resource can use either the L5 or L7 the combined only works with an L7 A CAUTION The L5 and L7 power supplies look identical Check the list number on the power supply before installing 336 Task List Set up Modem Pooling 1 Add Pooled Modem Paradyne 3800 Series 2 Set the Modem Connected to Data Module 3 Set the Modem Connected to the Data Terminal Equipment DTE 4 Set 7400A and 7400B Options Modem Pooling Return to Task List Add Pooled Modem Paradyne 3800 Series Begin Return to Task List Use this procedure for Paradyne 3800 Series modems For other types of modems refer to the vendor s documentation The pooled modem requires a WP90110 L7 power supply The L5 and L7 power supplies look identical Check the list number on the power supply before installing 1 Determine the port assignment of the circuit packs to be added if required 2 Install the appropriate circuit packs in assigned carrie
334. n to administer the data module that is associated with the TN2501AP ethernet port 15 Set the Type field to ethernet 16 Set the Port field to correspond to the circuit pack location The port number final two digits is always 33 for the TN2501AP circuit pack 17 Set the Link field to an unassigned or next available link number 18 Set the Network uses 1 s for Broadcast Address field according to the your network requirements 19 Type a unique name in the Name field 20 Press Enter to save your changes 21 If your system uses IP routing type add ip route and press Return 22 Administer IP routes to the TN2501AP circuit pack and press Enter to save your changes 23 Use the ping and status link commands to test the new IP connections that you have administered Add Multiple Announcement Return to Task List TN750C and TN2501AP circuit packs are required if the system has more than one announcement circuit pack No more than 1 TN750 or TN750B can reside in the system The TN750C or TN2501AP can install in any port or service TDM slot and need not reside in a control carrier for extra power holdovers Note Do not copy or restore announcements from a TN750C to a TN750 or TN750B circuit pack as this process may corrupt the announcement data This section provides information on IN750C Announcement Circuit Pack TN2501AP Announcement Circuit Pack Save and Restore Recorded Announcements TN750 and TN750B Announc
335. nd U S Robotics Modem Dip Switch Settings 4 Plug the modem into an AC power outlet 5 Turn on the modem using the switch on the front of the modem External Modem Connections for U S Robotics Modem modfrobo 030499 Figure Notes 1 Connect analog line here 2 DIP switch 5 must be up 3 Connect MODEM connector here 4 Connect power connector here U S Robotics Modem Dip Switch Settings Dip Switch 1 Setting Description UP Data Terminal Ready normal DOWN Data Terminal Ready override UP Verbal result codes DOWN Numeric result codes UP Suppress result codes DOWN Display result codes UP Echo offline commands DOWN No echo offline commands UP Auto answer on first ring or higher if specified in NVRAM DOWN Auto answer off UP Carrier detect normal DOWN Carrier detect override UP Load NVRAM defaults DOWN Load factory defaults UP Dumb mode DOWN Smart mode Return to Task List Connect the Monitor Keyboard and Mouse Begin Return to Task List Note Only make these connections if administered locally Not necessary if administered remotely You must connect these before inserting the TN802B IP Interface 1 Attach a VGA monitor to the VGA connector of the TN802 IP Interface external cable assembly 2 Attach the keyboard to the KEYBOARD connector of the external cable assembly 3 Attach the mouse to the MOUSE
336. ndant console 119 administering the system 91 106 administering TN464GP and TN2464BP 230 administration commands 92 administration commands introduction 92 administration terminals connectable 70 alarm connections 156 alarm wiring 143 alarms 121 125 362 terminal alarm notification 126 A Law companding 264 amphenol pins 419 analog line circuit protectors 164 analog station wiring 143 analog telephones 162 analog tie trunk wiring 145 announcement 213 214 playback procedure 357 announcements deleting 357 recording 357 testing 357 announcements moving 215 announcements moving from TN750B to TN750C 214 APP connector information 415 approved grounds 383 Argentina country code 113 AT control modem 369 attendant console 153 maximum cabling distance 142 attendant console LEDs 125 126 attendant console administering 119 attendant console cabling distances 154 attendant console installing 155 attendant console testing 356 AUDIX connections through processor interface 377 AUDIX sytem power procedures 95 AUDIX powering 91 Australia country code 113 Automatic Registration Tool ART 121 AUX trunk pinouts 415 auxiliary cabinet equipment 20 auxiliary cabinet cabling to MDF 79 auxiliary cabinets cabinet location 20 auxiliary connector outputs 148 auxiliary equipment classification 200 auxiliary equipment pin designations 415 auxiliary equipment pinouts 415 417 auxil
337. ndow IP Address Adapter 2 274 Microsoft TCP IP Properties 2 Digital Semiconductor 21143 based 10 100 mpbs Ethernet m Upgrade to TN802B R10 Begin eturn to Task List Note The upgrade takes about 20 minutes 1 Insert the flash disk into the right most slot on the TN802B IP Interface On the terminal a dialog box assigns a drive letter the default is D 2 Right click on Start Explore to open the Windows NT Explore pane and select the drive letter indicated in the previous step 3 Double click on Medpro and select the Setup icon 275 6 7 8 Follow the Install Shield procedure to transfer all the necessary files to the TN802 IP Interface In the Finish dialog box select I will restart later do not select Restart computer This would be a good time to read the Readme txt file Click on Start Settings Control Panel Services Select IP Trunk and click on Startup Do not click on Start Under Startup Type select Disabled and click OK to disable IP Trunk mode Note If IP trunk and MedPro services are both set to automatic the TN802B defaults to IP Trunk and MedPro features cannot be used 9 Select MedPro and click on Startup Do not click on Start 10 Under Startup Type select Automatic and click OK to enable MedPro mode WARNING When connected remotely via pcCANYWHERE only use the pcANYWHERE Restart Host Computer button on the toolbar to restart Windows NT 11 Clic
338. nel Service Unit Designation 1 BK Line in 0 2 Y Line in 1 3 Shield 4 R Line out 0 5 G Line out 1 281 Network Function Designation R1 RCV T1 XMT H700 383 Cable Pin Assignments Pin Color Channel Service Unit Designation 7 Shield Network Function Designation Not assigned Not assigned H700 383 Cable Lengths by Group Number Group Length 1 2 3 4 25 feet 7 7 m 50 feet 15 2 m 75 feet 22 9 m 100 feet 30 5 m Group 5 7 7 8 Installing a 3150 3170 Channel Service Unit Length 125 feet 38 1 m 200 feet 71 m 400 feet 122 m 750 feet 198 1 m Begin 3150 3170 Channel Service Unit Connections shows a typical connection from the H600 348quad cable to the CSU through the H600 307 network cable and to the network interface through the smart jacks The quad cable provides up to four connections using a 15 pin connector that plugs into the DTE jack on each CSU The H600 348 quad cable may require an adapter cable 1 Install the CSU as shown in 3150 3170 Channel Service Unit Connections 2 For some installations such as a DS1 converter use a Y cable to connect the DEFINITY System to the quad cable DS1 Converter Connections Using Double Headed cable shows the Y Cable Lengths Label all cables 3150 3170 Channel Service Unit Connections 282
339. nistrable slots for the given carrier type For si All slot fields are displayed Administration Commands Use the following administration commands to administer the Circuit Pack form Action Object Qualifier change dcircuit packs cabinet number display circuit packs xx cabinet number print or schedule Note If no cabinet number is specified this command defaults to 1 Change Circuit Packs Form Note Each page of the form represents 1 carrier within the cabinet specified on the command line All carriers and slots appear even if they are not included in the actual hardware This supports reconfiguration Cabinet Display only field This field shows the cabinet number as entered on the command line Carrier Display only field This field shows the letter of the carrier A through E circuit packs are being administered on Carrier Type Display only field This field shows the type of carrier Slot Display only field The slot equates to the physical slot of the given carrier the number of slots displayed depends on the system being configured For si configurations ALL slots that could possibly be administered are displayed even if they do not apply to the current configuration of the system This is to accommodate the situation when a system is being reconfigured Circuit Pack Cabinet Layout lists the slots to use and the circuit pack types that may be administered in those slot
340. nk auxiliary field from the AUX connector See Alarm Inputs at AUX Connector 2 Connect an external alarm output through pins 48 and 23 of the AUX connector See Alarm Output at AUX Connector 3 Note which device connects to which alarm and give this information to your Avaya representative for troubleshooting purposes 4 Connect emergency transfer power and auxiliary power as shown in Emergency Transfer and Auxiliary Power Auxiliary power includes power to an attendant console or adjunct device Alarm Inputs at AUX Connector Color AUX Connector White Blue AP1 Pin 26 Major Alarm Input Blue White Ground Pin 1 White Orange 2 Pin 27 Minor Alarm Input Orange White Ground Pin 2 Alarm Output at AUX Connector Color AUX Connector Violet Green EXTALMA Pin 48 Alarm Output Green Violet EXTALMB Pin 23 Ground Alarm Output 156 Emergency Transfer and Auxiliary Power Color AUX Connector Black Green XFERA8 Emergency Transfer Pin 36 Green Black Ground Pin 11 Black Slate ACCA8A Adjunct 48 VDC Pin 19 Slate Black Ground Pin 44 Return to Task List Connect Power Distribution Unit External Alarm Wires Begin Return to Task List The external alarm plug should already be connected to the J58890CH 1 Power Distribution Unit The pinout for the connector is shown in External Alarm Connector Pinout Note RS 232 alarms RXD DTR DSR TXD RS 232 GRD and RTS are not supported on the BU3200A Battery Interface Unit
341. nly type status system all and press Enter Ensure that the standby SPE is notin the maintenance state If it is wait for the maintenance state to finish 5 Use one of these installation methods Direct connection between the switch and REA No connection between the switch and RFA Direct connection between the switch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File Note This procedure sends the License File to the switch and installs it 2 Ifthe system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints No connection between the switch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File to your laptop PC 2 Open the License Installation Tool LIT application at your laptop PC 3 Use the LIT instructions to add a switch connection profile to the tool 4 Use the LIT instructions to install the License File on the switch 5 f the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints A CAUTION Save Translations CallVisor ASAI Begin Return to Task List 1 If the system is high or critical
342. nnection points Note Re manufactured repaired ICSU units and any manufactured after May 7 2002 are marked as 120A3A A CAUTION Do not plug the 120A3A into any circuit packs other than a TN464F or TN767E or later or TN2464 or TN2313 Do not connect the 120A3A to any interface other than 700A DS1 loopback jack Be sure the DS1 circuit pack is set for 24 channel operation 1 544 Mbps The 120A3A does not operate with the S2 channel interface A switch on the circuit pack or administration sets this option CAUTION Always wear an anti static wrist strap when installing a 120A3A module Do not touch the external alarm cable when it is connected to the 120AS3A Static discharge can damage connector terminals and relays 1 Unplug the DS1 circuit pack from its slot 2 Install a 4C retainer in the 50 pin plug associated with the DS1 circuit pack slot 3 Plug the 25 pair connector on the 120 directly into the plug associated with the DS1 circuit pack slot 4 Secure the 4C retainer around the 120A3A 5 Attach the supplied H700 383 cable to the 120A3A and to the 700A loopback jack This cable is directional To determine the end that connects to the 120A3A perform a continuity test between pins 3 and 7 The end with this continuity is the 120A3A end The shield is grounded only at the 120A3A end Use the cable provided If using cabling other than that provided with the 120A3A see H700 383 Equivalent Cable Guidelin
343. ns CallVisor ASAI Add Packet Bus Support if it is not already installed e Add Circuit Packs CallVisor ASAI Install Cables CallVisor ASAI Enter Added Translations CallVisor ASAI Resolve Alarms CallVisor ASAI Save Translations CallVisor ASAI 216 New Duplicated G3r installations only New simplex and upgraded G3r only Deliver License File CallVisor ASAI Begin Return to Task List A CAUTION This procedure must be done immediately after you upgrade the software If the license file is not installed within 10 days the switch enters a No License mode and shuts down all call processing 1 2 Retrieve the RFA License File with both serial numbers from the RFA Application Type set time and press Enter Ensure that the system date and time are set correctly Use one of these installation methods Direct connection between the switch and REA No connection between the switch and RFA Type save translation and press Enter After the translations have been copied about 10 minutes the system returns an error code which must be a zero otherwise the translations are not copied Type reset system 4 and press Enter Wait until the system has completely reset before continuing Type change cabinet 1 and press Enter In the Carrier Type column change the B carrier to processor and submit the form Type change system parameters duplication and press Enter Setthe Enable Operation of SPE Duplicat
344. nsert the TN799x circuit pack into the port slot identified earlier 2 Insert the TN802B IP Interface into the rightmost of the three slots you reserved for it see J58890MA 1 L30 IP Interface Assembly and seat it properly When you plug in the TN802B IP Interface the circuit pack starts to boot and the LCD reads PC Boot The circuit pack automatically reboots and after about 3 to 4 minutes the LCD changes to MEDPRO If the TN802B is pre administered at the factory it reboots several times to initialize to MedPro mode Note For an initial installation the TN802B IP Interface needs to be administered first If the TN802B is not pre administered go to Administer the IP Interface TN802B IP Interface faceplate 251 pdimapd 030899 Figure Notes 1 LCD display 2 Reset button recessed 3 Red board status LED 4 PCMCIA card slot 5 Yellow PCMCIA disk in use LED J58890MA 1 L30 IP Interface Assembly 252 indfmapd 031299 Return to Task List Administer the TN799x C LAN Begin Return to Task List To administer the TN799x circuit pack refer to the Administration for Network Connectivity for Avaya Communication Manager Administer the IP Interface Begin Return to Task List Administration is done either locally or remotely If administered locally proceed with the following administration steps If administered
345. ntative and are available on the following Web site http www avaya com support Japan This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may occur in which case the user may be required to take corrective actions COPEL PALMERS ERS VCCI OX CH ORES ER CEATA UE To order copies of this and other documents Call Avaya Publications Center Voice 1 800 457 1235 or 1 207 866 6701 FAX 1 800 457 1764 or 1 207 626 7269 Write Globalware Solutions 200 Ward Hill Avenue Haverhill MA 01835 USA Attention Avaya Account Management E mail totalware gwsmail com For the most current versions of documentation go to the Avaya Web site http www avaya com support Installation for MCC1 Multicarrier Cabinets Made Easy 15 Install and Connect MCC1 uncis d NH 1 7 Install Madoninanleations Cabli ng 49 af ution Frame Hardware duc ot eee de eck TUE Ure e a MDF Cross Connect Fields osse ae dak 4 ae A ERR EK DR AHO e Main Distibuton Frame es uno co ROGER ce eek XO EEG Xo9 uo D Acimi nisiratia n Terminals pirak oh Ge ate done 150 Install Insta
346. nthesis Add Code Calling Access Add CallVisor ASAI Add Packet Bus Support Add DCS Interface Administer TN464GP TN2464BP with Echo Cancellation Installing Other Equipment To install the following equipment you must refer to the installation and usage documentation that comes with the product DEFINITY Wireless Business System Cellular Business System Forum PCM 199 DEFINITY Wireless Business System To install and test the hardware refer to DEFINITY Wireless Business System Installation and Tests Guide To interface the Wireless Business System to the system cabinet refer to DEFINITY Wireless Business System Interface To operate the wireless handsets refer to DEFINITY Wireless Business System User s Guide Cellular Business System The DEFINITY Cellular Business System allows use of the same full feature cellular telephone inside and outside of the building The system supports up to 600 users Total system coverage is up to 4 million square feet Refer to the installation and usage documentation that comes with the system components Forum PCM The Forum Personal Communications Manager uses a Forum switch serving as an adjunct to the Avaya Media Gateway to manage mobility The system uses Cordless Telephone Generation 2 CT2 technology which is a global standard for wireless telephone service This standard defines the radio interface between the Forum pocket telephones and the base stations in the system
347. off premises wiring required At the MDF jumpers must be connected between 1 row connecting block in the white field and up to 3 rows connecting blocks in the purple field At the station location a WP 90929 List 1 Concentrator Cable is used There are 8 station appearances on each of the 3 fingers of the concentrator cable The maximum distance from the system cabinet to the out of building voice terminal is 6000 feet 1828 8 meters using 24 AWG 5 0 5 mm wire The maximum range of out of building analog telephones 500 2500 or 7100 types connected to an analog line circuit pack should be such that the maximum loop resistance does not exceed 1300 ohms Connections for 1 to 8 Out of Building Analog Telephones 162 crdfobt CJL 101396 Figure Notes 1 Locally Engineered Cables and Equipment 2 Out of Building Wiring 3 25 Pair Connector 4 Multi Pair Protector Units Primary Protectors with Heat Coils or Equivalent with Sneak Current Protection 5 356A Adapter 6 B25A Cable Male to Female 7 Out Of Building Analog Telephones 8 Part of Main Distribution Frame MDF 9 Station Side 10 System Side 11 White Field 12 Purple Field 13 Cross Connect Jumpers 14 Tip and Ring Wires 15 To Analog Line Circuit Pack Connections to 24 Out of Building Telephones
348. omenclature strips above the carriers to identify the slots 6 Label connectors on each end of the cables that connect to the cabinet 7 Route the cables down the sides of the cabinet and store the excess cable slack in the cable slack manager as previously described Connect Trunk Pairs Using Concentrator Cables T9 lt lt lt lt gt lt gt gt lt lt lt lt gt lt lt gt lt lt lt lt lt 0 9 4 NEW796 THC 031296 Figure Notes 1 Trunk Auxiliary Field 2 To Control Carrier AUX Connector 3 Concentrator Cable WP90929 List 1 4 Concentrator Cable WP90929 List 3 5 A25D Male to Male Cable 6 Alternate Block Rows 7 RJ21X RJ2GX Network Interface 8 Sneak Fuse Panel 9 B25A Cable 10 Central Office Trunks 11 System Cabinet Return to Task List Connect Trunk Pairs to Cabinet Using Jumper Wires To Establish 3 Pair Modularity Begin Return to Task List 3 Pair Modularity for Trunk Pairs for 1 Pair Trunks and 3 Pair Modularity for Trunk Pairs for 3 Pair Tie Trunks show trunk pairs connected to the cabinet with jumper wires to establish 3 pair modularity To connect the trunk pairs to the purple field 76 1 Connect B25A cables between the network interface and the sneak fuse panels See 3 Pair Modularity for Trunk Pairs for 1 Pair Trunks 2 Connect A25D B25A cables from the sneak fuse panels to the 110 type terminal block type connecting
349. ons Pin on Modular Plug gt a U nm 4 wire 2 wire 8510T Analog NT1 Z3A1 amp 302C1 302C1 Basic Station Z3A2 8400 Series 8400 Series Rate Modem Asynchro 603E 9403 603E 9403 Interface nous Data 9434 9410 9434 BRI Units with ADU adjunct Data Speaker Module phone TXT TXT TXR TXR PXT TXT PXT T PXR T 144 Port Circuit Pack and Telephone Pin Designations 5 R PXT No R 6 PXR TXR Lm PXR 7 48VDC 48VDC 48VDC modular 48VDC 8 GRD GRD GRD Jack GRD Circuit TN754 TN2181 2 wire TN556 TN2183 TN2198 TN726 Pack 4 wire digital digital 16 ISDN BRI Analog line 2 wire Data Line 8 port port Line 16 port Basic TN2224 2 wire Rate digital 24 Interface port line PX PBX transmitT Tip A TX Terminal transmitRRing B Return to Task List Analog Tie Trunk Example Return to Task List This example shows how to connect analog tie trunk wiring from one DEFINITY System to another DEFINITY System 1 Set the option switches on the port circuit pack such as TN760 Go to Option Switch Settings for detailed information 2 Install cross connect jumpers to connect the pins from the tie trunk circuit pack to the appropriate leads on the external tie trunk Analog Tie Trunk Wiring shows a DEFINITY System tie trunk connected to a DEFINITY System tie trunk Names of the tie trunk leads must be determined from the manufacturer or supplier of the external trunk circuit 3 Administer on the Trunk Group Scree
350. or s Software for Avaya Communication Manager 215 Add Speech Synihesis Begin Return to Task List The Speech Synthesizer circuit pack is required when the Voice Message Retrieval Automatic Wakeup or Do Not Disturb features are activated The circuit pack does not require administration 1 Determine the port assignment of the Speech Synthesizer circuit pack to be added 2 Install the Speech Synthesizer circuit pack in the designated carrier slot Add Code Calling Access Begin Return to Task List The tones for the Code Calling feature are generated by the Tone Clock circuit packs in the port networks 1 Install a TN763B C D or TN417 Auxiliary Trunk circuit pack or a Speech Synthesizer circuit pack and connect for Loudspeaker Paging The Code Calling Access feature shares the same ports as Loudspeaker Paging An Auxiliary Trunk circuit pack provides 4 ports for Loudspeaker Paging and Code Calling Access 2 Administer the form listed under Code Calling Access in the Administrator s Guide for Avaya Communication Manager Add CallVisor ASAI Return to Task List Note Adding CallVisor ASAI requires a service interruption when you add packet bus support and you install TN570 circuit packs as part of that support Give the customer advance notice of the scheduled addition See Add Packet Bus Support for further information Task List Add CallVisor ASAI Deliver License File CallVisor ASAI Save Translatio
351. ormally positioned adjacent to the PPN cabinet but may be located remotely in a different room or a different building A configuration can have up to 5 EPNs in a MCC1 1 The procedure for installing an EPN cabinet is the same as for the PPN cabinet 2 If earthquake protection is required Install Earthquake Protection for MCC1 3 If earthquake protection is not required level the cabinets and adjust and lock the cabinet stabilizing bolts to keep the cabinets from moving Note To install a new EPN cabinet to an existing system refer to the Upgrades and Additions for Avaya DEFINITY Server Return to Task List Position the Auxiliary Cabinet Optional Begin Return to Task List 1 Position the Auxiliary cabinet next to the PPN cabinet or EPN cabinet if installed The location of equipment inside the Auxiliary cabinet is specified in the Customer Service Document CSD 2 If earthquake protection is required Install Earthquake Protection for MCC1 3 If earthquake protection is not required level the cabinets and adjust and lock the cabinet stabilizing bolts to keep the cabinet from moving Return to Task List Install Auxiliary Cabinet Equipment Begin Return to Task List The Auxiliary cabinet allows for carrier 23 in 58 4 cm rack or panel mounting of hardware The following equipment is furnished with the cabinet Fuse panel Distributes 48 VDC power to fused cabinet circuits Power receptacle
352. otal output Each output circuit is current limited by a Polymer Positive Temperature Coefficient Resistance Device PTC that limits the maximum output to 12 watts Each 1146B output has an LED to indicate the status of the PTC If the LED is on the PTC has a short on that power pair Not all outputs can simultaneously provide 12 watts The average power per output cannot exceed 8 6 watts 275 32 8 6 The 1145B is designed to power one ISDN terminal or DCP adjunct per output The maximum number of terminals or adjuncts is 32 at less than or equal to 6 25 watts each The 1145B is required for installations outside the United States Auxiliary power local or bulk is always required for the following Attendant Console 302C1 Any 8520 terminal Any 7500 or 8500 series terminal with an asynchronous data module e Any 7500 series terminal whether in passive bus or point to point one per BRI port Any 8510 terminal in passive bus or with an asynchronous data module unless the 8510 will not be used to support data or video PassageWay adapter interface Some 8400 series terminal and adjuncts e Some 7400 series terminal and adjuncts 1145B 1146B Mounting Arrangement 184 1149 Battery On Battery Reserve o 1145 Power Unit Charging Battery Output Power On 000
353. other component As an example install the attendant console using the procedures in Install and Wire Telephones administer it using the procedures in the Administrator s Guide for Avaya Communication Manager and test it using the procedures in Test Telephones and Other Equipment You can also find information on these topics here Option Switch Settings Approved Grounds Administering Fiber Optic Cables Connector and Cable Diagrams Pinout Charts 16 Install Connect 1 Multicarrier Cabinet This section describes how to install the MCC1 Multicarrier cabinet For information on Single Carrier Cabinets go to Install and Connect SCC1 Single Carrier Cabinets Floor plans and equipment layouts for typical system installations are provided in the System Description book Note Before you begin the cabinet installation check the location of the AC DC power receptacles The receptacles must be on separately fused circuits not controlled by wall Switches They must be located within 10 feet 3 meters of the cabinet and outside the Main Distribution Frame MDF area Task List Install and Connect MCC1 Perform these tasks before you begin the installation 1 Check Customer s Order 2 Unpack and Inspect Cabinets 3 Unpack and Inspect Auxiliary Cabinet 4 If you cannot get timing from the service provider you may need to install a Stratum 3 clock If this system includes a Stratum 3 clock go to Installing the
354. ounding strap while handling the circuit pack 1 Remove connector if any from the back of the switch cabinet corresponding to the TN2501AP circuit pack slot 2 Insert the circuit pack into any port slot and close the latch securely 210 At first both the red and green LEDs are on steady then the green LED flashes If there are announcements on the circuit pack the amber LED flashes while the announcements are copied from FLASH to RAM After approximately 3 5 minutes all of the top 3 LEDs go out although this time is longer if there are announcements already recorded on the circuit pack Note If the TN2501AP or TN750 circuit packs are at the system limit and you insert a VAL circuit pack the red LED on that circuit pack stays on indicating that the system does not accept it 3 4 Connect the Backplane Adapter to the Amphenol connector on the back of the switch cabinet corresponding to the TN2501AP circuit pack slot Connect the LAN cable to the RJ 45 connector on the Backplane Adapter Configuring the system for the TN2501AP Begin 1 10 11 12 At the SAT type list configuration board board location and press Return The System Configuration report appears Use this report to ensure that the switch recognizes the TN2501AP circuit pack after it is latched in the carrier slot Verify the following field values Board Type shows VAL ANNOUNCEMENT Code is TN2501AP At the SAT type change node na
355. oute the cable from the cabinet to the wall Place the cable beside 1 of the rows of columns in the cable slack manager Note Retainers mounted on the columns keep the cable from protruding above the top of the base of the cable slack manager Determine the length of the cable required to reach from the cable slack manager to the assigned connecting terminal block Use D rings on the wall to support the cable The cable must be supported e Coil the cable around the columns in the cable slack manager to store cable slack The first run should always go across the full length of the 5 columns in the cable slack manager Connect the cable to the assigned connecting terminal block Avoid placing copper cables where they may bend or strain fiber optic cables Control Carrier Outputs Cable Installation A connector on the rear of the Control Carrier is labeled AUX A 25 pair cable connects the AUX connector to a 110 type terminal block in the yellow field of the trunk auxiliary field The AUX connector outputs include the following Alarm monitoring for the processor interface 57 7 DC power 48 VDC sources for emergency transfer units power 48 VDC sources for remotely powering a total of 3 attendant consoles or executive voice terminal adjuncts remote maintenance internal modem connection location e Access to a relay contact is available to actuate a light bell or similar type cus
356. ovide power to additional devices A CAUTION Total power cannot exceed 275 Watts The maximum ISDN terminal mixture is twenty four 7500 series and twenty four 8500 series terminals The maximum DCP terminal mixture is twenty four 7400 series and twenty four 8400 series or sixty four 8400 series terminals The expanded power distribution unit kit contains One 1146B Power Distribution Unit One T Cable Two 8 32 x 1 2 inch Shoulder Screws One 8 32 x 1 inch Screw e One Spacer Bracket Refer to Expanded Power Distribution Unit while installing the power distribution unit 1 Set the spacer bracket onto the mounting plate and secure with the 48 32 x 1 2 inch shoulder screws The spacer bracket is not shown in the figure but is installed behind the top power distribution unit 2 Slide the keyhole slots in the power distribution unit over the shoulder screws 191 3 Insert the 8 32 x 1 inch screw through the distribution unit through the spacer bracket and into the plate The mounting hole is located just above the wire clip Tighten the screw securely 4 Set the battery back up switch to the 1 32 down position 5 Power down the 1145B unit as described on the label on the side of the unit 6 Remove the output power cable between the 1145B and the 1146B units The cable will not be reused 7 Connect the P1 connector end of the T cable to the bottom power distribution unit Connect the P2 connector to the top d
357. owing step 3 Determine which slot 1 or 2 will contain the new fiber optic circuit pack Remove the circuit pack or the blanking plate from this slot Note If a circuit pack is removed from the required slot it must be installed into a different slot in the cabinet All translations associated with this circuit pack must also be moved 391 4 Remove the circuit pack or the blanking plate from the slot next to the slot determined in step 3 Two consecutive open slots are required to install the fiber optic adapter Note If a circuit pack was removed in step 4 it will be replaced into the same slot in the next procedure 5 Install the new circuit pack 6 Open the rear door 7 From the rear remove the I O cable connector plate associated with the slot that will contain the new fiber optic circuit pack See Remove the 1 0 cable connector Using a supplied cable tie secure the removed I O connector to nearby cabling See Secure the I O cable connector From the front remove the fan cover See Remove the fan cover 9 Fiber pass thru kit equipment indapkit RPY 012398 Figure Notes 1 Pass thru Tool 2 SC SC Fiber Optic Adapter 3 ST SC Fiber Optic Adapter 4 Fiber Optic Cable Multimode or Single mode 5 Fiber Optic Cable Disconnect Label 6 Connector Adapter Bracket 7 Cable Tie 8 Cable Tie Mount Fiber Pass Thru Kit Equipment list 392 Quantity 1 1 1 1 1 1 1 1 1 1
358. owing steps a PC with Windows 95 or Windows NT 4 0 may be substituted for the dumb terminal Use the Hyperterminal terminal emulation application 2 3 4 Oo oO Connect the opposite end of the RS 232 cable to a dumb terminal Set the dumb terminal to full duplex mode Type AT amp N6 to set the baud rate to 9600 The modem connects at 9600 baud but throughput is at 1200 baud Type AT amp WO to save the setting into non volatile RAM Set Switch 5 to the OFF up position to disable auto answer Disconnect the RS 232 cable from the terminal and connect it to the TERMINAL connector on the rear of the system cabinet Connect External Modem to PPN 9 cydfepnm KLC 100397 Figure Notes 1 U S Robotics External Modem 329 2 RS 232 Cable 3 Processor Port Network Return to Task List Add External Modem to TN1648B Begin Return to Task List Use a type approved external modem 1 2 Unpack and inspect the equipment received See External Modem Pass Thru Kit Equipment for the parts and Parts List for a list of parts Actual equipment may vary in appearance and may ship in separate packages Open the front door Note Administration may be required before removing the circuit pack in the following step 3 o ON Oo oO fF 11 12 13 14 15 16 17 18 19 20 Determine which slot will contain the new circuit pack Remove the circuit pack or the apparatus blank fro
359. pancies in circuit pack type or quantity to your Avaya representative For detailed circuit pack descriptions refer to the System Description book 2 Check the system adjuncts for damage and report all damage according to local shipping instructions Correct Shipping Errors Begin Return to Task List 1 Red tag all defective and over shipped equipment For Streamlined Implementation in the United States call 1 800 772 5409 For customers outside the United States contact your order service agent Position the PPN Cabinet Begin Return to Task List 1 If the system is supplied with cable ductwork space the cabinets on 32 in 81 3 cm centers 1 8 in 0 3 cm They must be level and must be square with respect to each other 2 If the system is supplied with cable slack managers place the cabinets far enough from the connection field to lay down the 32 in 81 3 cm slack managers and to provide a little extra room for the cables to access the cable slack managers 3 If earthquake protection is required Install Earthquake Protection for MCC1 4 If earthquake protection is not required level the cabinets and adjust and lock the cabinet stabilizing bolts to keep the cabinet from moving 5 Atthe bottom of the cabinet install hole plugs provided with cabinet in the holes previously occupied by the 4 carriage bolts Return to Task List Position the EPN Cabinets Begin Return to Task List Each EPN cabinet is n
360. pe ground 383 WATS trunks 296 Wireless Business System 200 wiring 1146B power distribution unit 193 2 wire digital station 143 alarm 143 analog station 143 analog tie trunk 145 battery 191 CO trunk 143 DID trunk 143 digital tie trunk 146 DS1 tie trunks 146 off premises stations 161 316 pin designations 415 procedures 139 183 telephone connection 142 Z ZD8AJ adapter 63 436
361. pletely spin down before unplugging the assembly See DEFINITY AUDIX System Power Procedures for the proper procedures 4 f the red LEDs still do not go off refer to Maintenance for Avaya MultiVantage DEFINITY Server SI or Maintenance for Avaya MultiVantage DEFINITY Server Note Ignore the red alarm indication LED on the TN767 or TN464 2464 DS1 circuit pack until after the DS1 circuit pack is administered Alarms will appear in the Alarm Log when power is applied to the system before all equipment connecting to port circuit packs is installed Normally some alarms will be logged when power is applied to the system but should be resolved quickly If no equipment is connected to the port circuit packs alarms associated with these ports can take up to four hours to log but will clear automatically after all equipment is installed and operating correctly Country Codes Country Code Country Code USA 1 Czechoslovakia 14 Australia 2 Russia 15 Japan 3 Argentina 16 Italy 4 Greece 17 Netherlands 5 China 18 Singapore 6 Hong Kong 19 Mexico 7 Thailand 20 Belgium 8 Macedonia 21 Saudi Arabia 9 Poland 22 United Kingdom 10 Brazil 23 113 Country Codes Country Code Country Code Spain 11 Nordic 24 France 12 South Africa 25 Germany 13 Typical System Parameters Country Options Screen change system parameters country options Page 1 of 21 SYSTEM PARAMETERS COUNTRY OPTIONS Companding Mode A Law Base Tone Generator Set 440Hz PBX dia
362. primary facility failure is known as the secondary facility The TN1654 allows either facility A or B to be a primary channel The control channel is restricted to only the A or B facilities This permits full 24 channel access T1 or 31 channel access E1 for facilities C and D to support user traffic DS1 Converter Connections for T1 Service Part 2 amp Oo 8 m 000000000000 B Clo es La 8 00000000000 5 0 a c B hidfcsu3 KLC 091799 Figure Notes 1 H600 348 Quad Cable 2 15 Pin Male D Connectors to DTE Jacks on CSU 3 Channel Service Unit CSU 4 H600 383 Cable RJ 48C to RJ 48C 5 Network Interface 312 6 700A Loopback Jack 7 Cables DS1 Converter Connections for 120 ohm E1 Service Part 2 9 S 5 eiie m2 o I 5 5 5 eue Figure Notes 1 H600 348 Quad Cable 2 15 pin male D connectors to DTE jacks on customer provided network int
363. provided by the local telephone company The off premises stations can appear on any of the RJ21X network interfaces provided for the Central Office CO trunks A CAUTION Only an FCC approved or equivalent analog type telephone for example a 2500 type can be used as an off premises station The TN746B and TN2183 Analog Line circuit packs can be used for off premises stations 1 Connect an A25D cable between the RJ21X network interface and a sneak fuse panel See Install Sneak Fuse Panels for details 2 Atthe MDF connect jumper wires between 1 row connecting block in the green field and up to 3 rows connecting blocks in the purple field to concentrate the analog line pairs Connect 250 cable between the sneak fuse panel and the 110 type terminal block connector associated with the green row in Step 2 A Install a green label on the 110 type terminal block to identify the remote location 5 Administer per the Administrator s Guide for Avaya Communication Manager Return to Task List 316 Installing the Stratum 3 Clock Use this task list to install a Stratum 3 clock Task List Install the Stratum 3 clock Unpack and Inspect Stratum 3 Clock Cabinet Install and Position Stratum 3 Clock Cabinet Connect AC Power to Stratum 3 Clock Cabinet Check and Connect Commercial AC Power Connect DC Power and Ground to Stratum 3 Clock Cabinet Connect Clock Cabinet Grounding Connect Stratum 3 Clock DC Power
364. ptable medium for grounding the building entrance protector entrance cable shield or single point ground of electronic telephony equipment If more than 1 type of approved ground is available on the premises the grounds must be bonded together as required in Section 250 81 of the National Electrical Code Grounded Building Steel The metal frame of the building where it is effectively grounded by 1 of the following grounds acceptable metallic water pipe concrete encased ground or a ground ring Acceptable Water Pipe A metal underground water pipe at least 1 2 in 1 3 cm in diameter in direct contact with the earth for at least 10 ft 8 m The pipe must be electrically continuous or made electrically continuous by bonding around insulated joints plastic pipe or plastic water meters to the point where the protector ground wire connects A metallic underground water pipe must be supplemented by the metal frame of the building a concrete encased ground or a ground ring If these grounds are not available the water pipe ground can be supplemented by 1 of the following types of grounds Other local metal underground systems or structures Local underground structures such as tanks and piping systems e Rod and pipe electrodes A 5 8 in 1 6 cm solid rod or 3 4 in 2 cm conduit or pipe electrode driven to a minimum depth of 8 ft 2 4 m e Plate electrodes Must have a minimum of 2 square ft 0 185 square m of me
365. pter later 2 Slide the pass thru tool to the rear of the cabinet See Insert the pass thru tool 3 Slide the tool to the rear of the cabinet A caution Avoid bending fiber optic cables to a radius smaller than 1 5 inches 3 8 cm to prevent mechanical stress on the cables A caution During the actual installation of fiber optic components use either all beige or all blue adapters Beige denotes multimode fiber and blue denotes single mode fiber Do not mix beige with blue 4 Attach the supplied fiber optic cable to the adapter 395 5 Pull the tool with adapter and cable attached out through the front of the cabinet See Fiber Optic Cable and Adapter 6 From the rear route the fiber optic cable through the opening vacated by the I O cable connector 7 f necessary remove the beige fiber adapter from the tool and plug the fiber optic cable into the SC SC single mode or SC ST multimode adapter See Bracket Attachments 8 From the front of the I O connector adapter bracket with fiber cable snap the adapter into the supplied I O connector adapter bracket Snap the I O connector adapter bracket into the I O connector opening 10 Attach the outside fiber plant to the I O connector on the rear of the cabinet 11 Wrap the cable disconnect label around the fiber optic cable See Cable disconnect label Avoid bending fiber optic cables to a radius smaller than 1 5 inches 3 8 cm to prevent mechanical stress on
366. r D Lead and Attention Control Modems Set Option Display Set 300 Speed Set 1200 Speed Set 2400 Speed Set 4800 Speed Set 9600 Speed Set 19200 Speed Set AT Control Set CI Lead Set CI2 Lead Set CH Lead Set CH2 Lead Set LL Lead Set REMOTE Loop Set RL Lead Set SIGLS Disc Set TM Lead Option 300 1200 2400 4800 9600 19200 AT CI Cl2 CH CH2 LL REMLOOP RL SIGLS DISC TM D Lead Settings Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 OFF Note 2 Note 2 Note 2 Note 2 Note 2 Grant Note 2 ON Note 2 Attention Control Settings Note 1 Note 1 Note 1 Note 1 Note 1 Note 1 ON Note 2 Note 2 Note 2 Note 2 Note 2 Grant Note 2 ON Note 2 Note 1 Set speed to match remote modem At least one speed must be set ON Note 2 Set to match remote modem Return to Task List 369 Modem Fields Modem Connection External Modem Option Settings Return to Task List The COMSPHERE 3700 3800 and 3900 series recommended external modems may require option switch settings Refer to the documentation that accompanies each modem to set the options Note A locally obtained type approved external modem may be used Contact your Avaya representative for more information DEFINITY ECS operates with the COMSPHERE modems set to the factory default settings The modem settings and descriptions are listed in Modem Fields Description Modem Name This field is 20 characters
367. r TN1654 entered on page of the form 1 544 indicates domestic USA T1 operation and 2 048 indicates international E1 operation See at DS1C Converter Complex Administration for TN574 Circuit Packs for more information Fiber Link Administration form for E1 TN1654 Circuit 051 Converter Complex Administration page 2 of 3 am fiber link next Page 2 of 3 gt FIBER LINK ADMINISTRATION A PNC 051 CONVERTER DS1CONV ATTRIBUTES DS1CONV Board Location 01B01 DS1CONV Board Location 02B01 DS1CONV Board Type TN1654 DS1CONV Board Type TN1654 DS1 CONVERTER FACILITIES A B Facility Installed yes yes yes no Bit Rate 2 048 Facility Startup Idle Code 11101000 Line Coding hdb3 hdb3 hdb3 hdb3 CRC yes Line Termination Facility A Circuit ID 09876543 Facility B Circuit ID 234567889 Facility C Circuit ID 434566335 Return to Task List DS1 Converter Complex Administration for E1 TN1654 Circuit Packs Return to Task List Fiber Link Administration form for E1 TN1654 Circuit Pack DS1 Converter Complex Administration page 2 of 3 allows you to admininster the DS1 converter The following unique fields display when administering a E1 TN1654 DS1 Converter Bit Rate Displays when the 051 Converter circuit pack is TN1654 Enter either 1 544 for domestic USA T1 operation or 2 048 for international E1 operation Note Since one bit rate applies for all facilities within the same DS
368. r mode 253 connect modem 249 259 IP Trunk mode MedPro mode 233 required hardware 247 257 IP interface TN802B installing in IP trunk mode 256 257 258 259 260 261 262 263 264 265 267 2770 2771 IP interface TN802B installing in MedPro mode 246 248 249 250 253 255 IP interface TN802B upgrading to TN2302AP IP Media Processor 243 244 245 IP interface assembly 233 Index IP Trunk mode 256 test external connection to LAN 271 test onboard LAN connections 271 IP interface LAN connections 271 IP Media Processor 233 238 installing 233 236 software limits 234 test external connection to LAN 240 IP Media Processor connecting 240 IP Media Processor installing 237 IP Media Processor upgrading from IP interface assembly 243 244 245 IP Media Processor upgrading to 241 242 IP network connection testing 360 IP Solutions 233 Avaya R300 Remote Office Communicator 233 onsite prerequisites 234 TN2302AP 233 TN802 B 233 IP Solutions inspecting 235 IP Trunk mode 233 256 assign IP address 265 change Mu Law to A Law 264 IP trunk mode administering 262 IP trunk mode installing 256 257 258 259 260 261 262 263 264 265 267 270 271 ISDN 380 BRI testing 359 PRI interface 380 ISDN BRI 203 fanout of multipoint installations 206 208 terminating resistor 203 ISDN BRI pinouts 417 ISDN BRI installing 209 210 ISDN PRI trunks 294 295 296 Italy country code 113 I
369. r slot if required 3 Type AT amp F amp D2 amp S4 D3S2 128x7V2S7 60S85 1 and press Enter 4 ATY0S10 100S78 2M0E0 N1 amp W and press Enter Return to Task List Set the Modem Connected to Data Module Begin Return to Task List 1 Type add data module next and press Enter Type pdm in the Type field Type x in the Port field Type dte in the Connected to field and press Enter Type add station next and press Enter Type 2500 in the Type field Type x in the Port field Type n in the Tests field and press Enter o ON Oo 25 WO Type add modem pool next and press Enter Type combined in the Group Type field Type 5 in the Hold Time min field ot N Type two way in the Direction field Type 9600 in the Speed field Type Full in the Duplex field a A o Type async in the Synchronization field 337 16 Type the port pair assignments in the Analog and Digital fields and press Enter Return to Task List Set the Modem Connected to the Data Terminal Equipment DTE Begin Return to Task List 1 Type add station next and press Enter 2 Type 2500 in the Type field 3 Type the port assignment in the Port field and press Enter Set 7400A and 7400B Options Modem Pooling Begin Return to Task List Determine if the 7400A or 7400B will be interfacing with D lead modems or attention control modems Use Options for D Lead and Attention Control Modems to interface with eith
370. rd reliability type backup disk incremental or If a high or critical reliability backup disk incremental both Press Enter Resolve Alarms Begin Return to Task List 1 Type display alarms and press Enter Examine the alarm log Resolve any alarms that may exist using the Maintenance for Avaya MultiVantage DEFINITY Server manual A CAUTION To prevent unnecessary trouble tickets do not enable the system alarms Alarm Origination feature until all installation and administration procedures are completed This section describes basic system start up procedures only and is not intended to identify all system alarms or error conditions Return to Task List Register the Switch for Maintenance Begin Return to Task List The Automatic Registration Tool ART is a web based tool that permits field technicians and TSO Database Administration DBA to register U S direct channel products The product that you are registering must have switch connectivity through the INADS line anlP address Note ART is not accessible from the public internet outside the Avaya intranet firewall 1 At your laptop PC direct your browser to this URL http spiexp1 eng avaya com 8000 cgi bin ART ARTstart cgi You can also save this URL in your Favorites or Bookmarks list The ART User Menu displays 2 Click on the Register a Product button The Enter Network Password dialog box appears 3 Type your ART User Name and P
371. re H096CO0 to disable V 42bis amp MNP Class 5 data compression algorithms The Paradyne products only use C0 to disable both algorithms This field is not case sensitive Default is upper case Turns on the V 42 LAPM and MNP error control protocols if available The field has a blank field of 6 characters as default The Paradyne products use the command WN5 to enable V 42 MNP Buffer error control while the Intel product uses N3 to provide similar functionality This V 42 MNP Buffer mode attempts to negotiate V 42 error control with the remote modem If this fails the modem changes to MNP if this fails no error control is used This field is not case sensitive Default is upper case Misc Init Param This field has a blank as a default and a field length of 20 characters This field supports any initialization parameters not already specified The AT commands specified in this free form field is always the last initialization parameters to be sent to the external modem This field is not case sensitive Default is upper case 370 Modem Fields Modem Connection Description Auto Answer Ring Number This field controls the number of rings required before the modem answers an incoming call This field has a blank default value in a field 6 characters long Typically the maximum permissible value for this register is 255 The values 1 255 denote the number of incoming ring cycles This field is not case sensiti
372. remotely call your service representative to start the process Note Refer to the Administration for Network Connectivity for Avaya Communication Manager for more information 1 Log in as craft Note If you have a dadmin login and password you can use them instead of craft and the craft password 2 Type change node names and press Enter 3 On Node Names Screen 2 type in the node name and IP address for the TN802B change node names Name clan al clan b1 default med al 9 Type change circuit pack and press Enter On Circuit Packs Screen 1 check the Code column to see if it says DSMAPD or MedPro If not type MEDPRO in the slot just above TN802B slot and press Enter Changing the one entry automatically changes the entry above it If it is in IP Trunk mode you get the following error message MedPro type requires TN802 with application Type MEDPRO on circuit packs form Type change ip interfaces and press Enter On IP Interfaces Screen 1 type in the information for the TN802B IP Interface Set the Enabled field to y and press Enter Note The customer provides the IP address subnet mask and gateway address At this time the TN802B LCD reads PC BOOT and about 3 to 4 minutes later reads MEDPRO with the asterisk flashing Node Names Screen 2 Page 2 of 6 NODE NAMES IP Address Name IP Address 192 168 1 31 192 168 2 31 0 192 168 1 81 Circuit Packs Screen 1
373. res 400B2 Adapier Connecting to a Modular Plug 1749428 KLC 060396 Figure Notes 1 Flush Mounted Information Outlet 2 Surface Mounted Information Outlet 3 To Individual Power Unit 4 400B2 Adapter 5 To Telephone 6 Destination Service Access Point DSAP Power Cord Return to Task List Connect an Analog Station or 2 Wire Digital Station Begin Return to Task List 143 This example is typical of the 2 wire digital stations 603E 84xx 94xx 302 1 2 wire analog stations 500 2500 71xx analog Central Office CO trunks Direct Inward Dial DID trunks and external alarms See 2500 Type Analog 1 Choose a peripheral to connect such as a 2 wire digital station 2 Choose the port circuit pack to use and its carrier and slot number from Port Circuit Pack and Telephone Pin Designations For example TN2183 Analog Line Cabinet 1 Carrier C Slot 1 3 Choose a port circuit on the port circuit pack for example port 3 4 Install cross connect jumpers to connect the pins from the 2 wire digital station to the appropriate pins on the port circuit pack 5 Administer using Administrator s Guide for Avaya Communication Manager 2500 Type Analog Telephone Wiring 24 4 28 3 R34 4 03 R3 2500wire RBP 071996 Figure Notes 1 2500 Type Analog Station 2 TN2183 Analog Line Circuit Pack Position 1C01 Port Circuit Pack and Telephone Pin Designati
374. res between the system side and the station side of the station distribution field on the MDF Connections for Telephone Used for Emergency Transfer LI 1 1758580b MMR 042996 Figure Notes 1 To Network Interface Circuitry 2 To TN747 or Equivalent Central Office Trunk Circuit Pack 3 To Blue or White Station Distribution Field 4 To Power Transfer Unit 5 To Control Carrier Auxiliary Connector Return to Task List Install Telephones Used for Emergency Transfer and as Normal Extension Trunk Auxiliary Field Begin Return to Task List 1 Connect a pair of wires between the 48V and GRD terminals on the yellow emergency transfer row connecting block to the EM TRANS RELAY PWR terminal See Connections for Telephone Used for Emergency Transfer and as Normal Extension 2 Connect CO trunk leads from the purple field to TC terminals on the yellow emergency transfer row connecting block for each trunk 176 3 Connect CO trunk leads from the green field to TK terminals the yellow emergency transfer row connecting block for each trunk 4 Connect telephone leads from the purple analog line circuit pack row connecting block to
375. ribution Frame Labels Label Graphic Symbols and Nomenclature shows the graphic symbols used on labels for the system cross connections information outlets and cables The labels are color coded to identify system wiring e Green To Central Office CO e Purple To system ports 54 Yellow To auxiliary equipment and miscellaneous system leads Blue To information outlets White From Main Distribution Frame to satellite locations 3 pair Each label identifies 2 rows on the terminal block The upper half identifies the row above it and the lower half identifies the row below it The labels are inserted into the clear plastic designation strips furnished with the terminal blocks The strip is snapped in place between the terminal block rows Label code number 1220A contains all of the required labels Label Graphic Symbols and Nomenclature uo Ed lid hide 9 ens Figure Notes 1 Write Floor or Building Identification on Label as Required 2 Cabinet 3 Carrier 4 Slot 5 Information Outlet 6 Site Satellite Closet 7 Tie Circuit 8 Floor 9 Building Off Premises Circuit Protection Protection from hazardous voltages and currents is required for all off premises out of building trunks lines and terminal installations Both over voltage protection lightning power induction and so forth and sneak current protection are required Sneak current protectors
376. rn to Task List For systems using A Law companding an additional procedure is necessary On the SAT 1 Busyout the trunk group associated with the IP trunk by typing busyout board UUCSS and pressing Enter In the Windows interface to TN802B 2 Click on Control Panel gt Services Highlight IP Trunk Service then click on Stop In the lower left hand corner right click Start gt Explore 3 4 5 Go to the c drive and click on the its folder then the bin folder 6 Double click on the its ini file to open it in Notepad 7 Under the MediaLib section go to COMPANDING MLAW Change MLAW to ALAW 8 Click on File gt Save to save the file 9 Click on File Exit to exit Notepad 10 Click on Control Panel Services 11 Highlight IP Trunk Service then click on Start Note Do not select Startup After service has started go to the SAT 12 Release the trunk group associated with the IP trunk by typing release board UUCSS and pressing Enter Return to Task List Assign Server and Domain Names Begin Return to Task List The Windows NT server identifies servers using a server name plus a domain name that locates the named server in a particular part of the network The TN802B IP Interface is shipped with generic server and domain names Assign replacement names that are meaningful within your network 1 Click on My Computer Control Panel Network 264 2 Select the Identification tab then click Change 3
377. rrier in the cabinet being administered Valid entries are dup switch node expansion control not used port processor and switch node Number Display only field Consists of two fields the Designator and Number fields The Designator field contains one of the following entries PN If the carrier is a port carrier processor carrier or unused carrier SN If the carrier is a switch node carrier or duplicate switch node carrier The Number field contains either the switch node number or port network number Duplicate The location for the duplicate of a switch node Only displays when administration of PNC Duplication is enabled If the Carrier Type is dup switch node the field displays the three character carrier address of the duplicate The first two characters represent the cabinet number the third character represents the carrier A through E This is a display only field if the Carrier Type field is switch node Cabinet Administration form ial Page 1 of m CABINET CABINET DESCRIPTION Cabinet 1 Cabinet Layout five carrier Cabinet Type processor Number of Portnetworks 1 Survivable Remote EPN _ Survivable Remote Processor ID Room Floor Building CARRIER DESCRIPTION Carrier Carrier Type Number Duplicate port PN 01 B processor PN 01 as A processor PN 01 X Fan D dup sw node SN 01 O1E E switch node SN 01 01D Return to Task List Add Cabinet 2 through N AvayaDEFINI
378. rter Set Circuit Pack Switches TN1654 DS1 Converter Installing TN1654s in a Port Carrier Installing TN1654s in a Switch Node Carrier Connecting a Port Carrier to a Switch Node Carrier TN1654 DS1 Converter Connecting Through a Channel Service Unit Mounting the 127A TN1654 DS1 Converter Return to Task List Circuit Pack Switches The configuration switches on the TN1654 must be set before the circuit pack is installed The TN1654 can be configured for either T1 or E1 operation All 4 facilities on the circuit pack are configured as a group It is not possible to have T1 and E1 facilities supported on the same circuit pack at the same time The T1 line impedance is fixed at 100 ohms and the T1 framing is selectable for ESF Extended Super Frame or D4 for each facility The E1 facility line supports termination impedances of 120 ohms for twisted pair and 75 ohms for coax wiring DS1 Converter Circuit Pack Switches shows the location of the switches TN1654 DS1 Converter Switch Functions and TN1654 DS1 Converter Switch Settings show the switch setting functions and positions respectively Circuit Pack and Cabling T1 Only The installation instructions are provided as examples only 305 Note Be sure to label all of the cables as they are installed 75 ohm E1 Interface Cabling For certain markets with 75 ohm E1 service the DS1 converter requires an adapter to convert the 120 ohms to 75 ohms 127A BALUN Coaxial Adapter
379. s Start Date Time Type the date and time that you want the firmware download to begin Stop Date Time Type the date and time that If the scheduled stop time is you want the firmware reached before the new firmware download to end image file has been downloaded to every circuit pack the system finishes downloading to the circuit pack in progress before aborting the remainder of the download schedule Target Location Type the UUCSS address of For a self download this circuit the circuit pack that you are pack must reside in the same updating location as the source pack For a C LAN distributed download enter up to 50 locations these must all be the same type of circuit pack If you are performing a self download enter only one target board location it is the same as the source board location The following screen provides an example of self download to a VAL circuit pack iange firmware download Page 1 of 1 FIRMWARE DOWNLOAD Source Board Location 01A10 irmware Image File Name tn2501ap_f05 bin Target Board Code TN2501 suffix AP Firmware Vintage Schedule Download y Remove Image File After Successful Download y Start Date Time 09 12 2002 13 30 Stop Date Time 09 12 2002 16 30 Target Target Target Target Target Location Location Location Location Location L 01A10 11 21 3l 41 X 12 22 32 42 J 13 235 Bais 43 Ll 14 24 34 44 Xs I5 25 35s 45 pm 16 26 36 46 Is IT 27 3T 47 3 18
380. s 1 100A Lightguide Interconnect Unit LIU 2 Multi Mode Connector C2000A 2 Single Mode Connector C3000A 2 3 Adhesive Backed Circuit Labels 4 1A4 Lightguide Trough 5 Fiber Patch Cord 6 1A6 Lightguide Trough 7 Open Lightguide Interconnect Unit LIU Typical Optical Interconnect Field 386 Y 1781477b 031496 Figure Notes 1 100A Lightguide Interconnect Unit LIU 2 Open Lightguide Interconnect Unit LIU Door 3 C2000A 2 Connector Multi Mode C3000A 2 Connector Single Mode 4 Labels 100A Lightguide Interconnect Unit Return to Task List The 100A Lightguide Interconnect Unit LIU consists of a cabinet with retainer rings to hold slack fiber cables mounting cutouts for two 10A lightguide connector panels and a door with circuit labels on each side See 100A Lightguide Interconnection Unit 100A Lightguide Interconnection Unit 387 cabinet CJL 031896 Figur
381. s Enter A screen similar to Sample of System Status after Expansion Link is Set is displayed Verify the MODEs of the expansion links have changed If any problems are indicated check the TDM cables and the inter cabinet cables ICC in the associated Expansion Port Network EPN 136 Sample of System Status before Expansion Link is Set status system all cabinets SYSTEM STATUS CABINET 1 EMERGENCY SELECT SERVICE CABINET TRANSFER SWITCH EXP LINK STATE MODE TYPE 1A unavail 01A01 02A01 in standby ESCC 1B auto on 01801 02B02 in active Command successfully completed Command Sample of System Status after Expansion Link is Set status system all cabinets SYSTEM STATUS CABINET 1 EMERGENCY SELECT SERVICE CABINET TRANSFER SWITCH EXP LINK STATE MODE TYPE 1A auto on 01A01 02A01 in active ESCC 1B auto on 01B01 02B02 in standby Command successfully completed Command Return to Task List Check Circuit Pack Configuration Begin Return to Task List 1 Type list configuration all and press Enter 2 Verify all circuit packs are listed in the reports Refer to the Maintenance for Avaya MultiVantage DEFINITY Server documentation to resolve any discrepancies Save Translations if Required Begin Return to Task List If any administration changes have been made save and make a back up copy of the translations 137 138 Install and Wire Telephones The wiring procedures are
382. s for each combination of Cabinet Carrier Carrier Type in an si configuration Code Enter the circuit pack code TN followed by a 3 or 4 digit number If there is a physical circuit pack installed in the slot the entry must match that of the circuit pack If there is equipment administered on a slot the equipment must be removed from the circuit pack before the circuit pack can be changed or removed Sfx Enter the circuit pack suffix if applicable 93 Display only field This field shows the alphanumeric name of the circuit pack such as Digital Line Note When the circuit pack physically inserted in the slot differs from what has been administered on this form a displays between the Sfx and Name fields Circuit Pack Cabinet Layout Cabinet Layout Carrier Type Use Circuit Pack Types Slots 1A SCC1 Basic Control Cabinet processor 01 10 All port circuit packs 1A SCC1 Enhanced Control Cabinet processor 01 16 All port circuit packs 1B SCC1 Duplicated Control Cabinet processor 01 10 All port circuit packs 1B C D SCC1 Port Cabinet port 01 18 All port circuit packs 2A amp 3A SCC1 Expansion Control expansion control 01 TN570 TN776 02 17 All port circuit packs 2B E D SCC1 Port Cabinet port 01 18 All port circuit packs 3B C D Change Circuit Pack Form Implementation Notes Change Circuit Packs Screen shows all fields that may be displayed The fields that appear on a particular screen
383. s NT 12 Restart the computer If administered remotely through pcANYWHERE click on the pcANYWHERE Restart Host Computer button on the toolbar to restart the computer or if administered locally on a monitor keyboard and mouse Click Yes in the dialog box to restart the computer TCP IP Properties Window DNS 268 Microsoft TCP IP Properties TCP IP Properties Window WINS Address 269 Microsoft TCP IP Properties 2 DEC PCI Ethernet DC21143 Return to Task List Check Network Services Begin Return to Task List When the server restarts make sure that the required network services have started correctly If you see an error dialog box then the network services did not start correctly Also check the NT Event Log 1 Click on My Computer Control Panel Network Services Make sure that the following services are listed N Computer Browser Microsoft Internet Information Server 2 0 NetBIOS Interface RPC Configuration Server Workstation Click the Protocols tab and examine the Network Protocols TCP IP protocol should be the only one listed 3 Click OK 270 Return to Task List Test the External Connection to the LAN Begin Return to Task List To test the external IP connections ping the IP Interface server and ping a known computer connected to your network 1 Click Start gt Programs gt Command Prompt 2 Type ping nnn nnn nnn nnn
384. s are installed in the system install a third rectifier module N 1 4 If 4 to 5 carriers are installed in the system install a fourth rectifier module 33 5 The fifth rectifier module slot is reserved for future system growth Rectifier Module Installation pedfrec KLC 101196 Figure Notes 1 Install Battery Interface Unit into Slot 1 2 Install Rectifier Modules into Slots 2 5 3 Rectifier Module 3 in Slot 4 4 Test Points 5 Main Circuit Breakers Return to Task List Connect Power and Ground s Begin Return to Task List 1 Have a qualified electrician connect and route wires from the AC load center to the dedicated electrical outlet for the power distribution unit Connect PPN Cabinet Ground 2 Connect 1 end of a 6 AWG 40 16 mm wire to the ground terminal block on the rear of the cabinet See Power Distribution Unit J58890CH 3 Route the CABINET GROUND wire to the AC load center single point ground block and connect Connect EPN Cabinet Ground s 4 Connect 1 end of a 6 AWG 40 16 mm CABINET GROUND wire to the ground terminal block at the bottom rear of the EPN cabinet See Typical Cabinet Grounding Wiring Diagram 5 Route the CABINET GROUND wire to the AC load center single point ground and connect 6 Connect each remaining EPN cabinet to the AC load center single point ground 34 Power Distribution Unit J58890CH V AV 010 020599 Figure No
385. s customer options and press Enter On screen 2 verify that the DS1 Echo Cancellation field is set to y If not contact your representative as this must be set by the license file 2 Type add change trunk group next number and press Enter See Trunk Features screen 3 On Trunk Features screen 2 set the DS1 Echo Cancellation field to y 4 Type add change ds1 UUCSS and press Enter See DS1 Circuit Pack Screen 5 On the 051 Circuit Pack screen set the Echo Cancellation field to y When set to y 2 new fields display EC Direction and EC Configuration f you know the echo is coming into DEFINITY keep the default setting for the EC Direction field of inward 230 f you know that the distant party is hearing echo that originates in DEFINITY or its line side stations or equipment set the EC Direction field to outward Keep the default setting for the EC Configuration field of 4 This setting minimizes extremely strong echo very hot signals or excessive clipping or breakup of speech from a distant party It reduces speech clipping but may allow slight residual echo or more background noise 6 Test the voice quality on a telephone connected through the TN464GP or TN2464BP circuit packs and known to have echo to see if the echo was eliminated 7 Ifthe echo still exists set the EC Configuration field to 1 2 or 3 then test the voice quality These settings provide help for the following scenarios S
386. s on your network that can be assigned to the IP Interface server Return to Task List Check your shipment Begin Return to Task List When your DEFINITY IP Interface Assembly order arrives at your site check the contents see Required Hardware 1 Inspect the shipping carton for damage before opening it If the box is damaged do not open it Inform the shipping company and ask for instructions on filing a claim 2 If the box is undamaged check the contents against the packing slip Check the condition of each component and note any damage or shortages on the packing slip See Required Hardware for what the carton should contain for each IP Interface ordered 3 Read and follow any directions inserted into the package by the factory The TN802B external cable assembly is a bundle of cables with an amphenol connector at the end of the bundle and various PC type connectors VGA Universal Serial Bus USB mouse keyboard Ethernet modem and COMO at the ends of the individual cables See TN802B IP Interface External Cable Assembly Look for the label where the bundle enters the amphenol connector Required Hardware Description Quantity TN799x C LAN circuit pack 1 TN802B IP Interface Assembly 1 or more H600 512 G1 external cable assembly 1 or more 259A connector 1 247 Required Hardware Description Quantity CAT5 or better cable 1 U S Robotics Sportster external modem Model 1 USR 33 6 EXT U S customers on
387. s registered equipment is capable of providing users access to interstate providers of operator services through the use of access codes Modification of this equipment by call aggregators to block access dialing codes is a violation of the Telephone Operator Consumers Act of 1990 This equipment complies with Part 68 of the FCC Rules On the rear of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for this equipment If requested this information must be provided to the telephone company The REN is used to determine the quantity of devices which may be connected to the telephone line Excessive RENS on the telephone line may result in devices not ringing in response to an incoming call In most but not all areas the sum of RENs should not exceed 5 0 To be certain of the number of devices that may be connected to a line as determined by the total RENs contact the local telephone company REN is not required for some types of analog or digital facilities Means of Connection Connection of this equipment to the telephone network is shown in the following table FIC Code SOC REN Network A S Code Jacks Manufacturer s Port Identifier Off On premises station OL13C 9 0F RJ2GX RJ21X DID trunk 02RV2 T 0 0B RJ2GX RJ21X CO trunk 02GS2 0 3A RJ21X CO trunk 02LS2 0 3A RJ21X Tie trunk TL31M 9 0F RJ2GX Basic Rate Interface
388. s test the ability of the Stratum 3 clock to correctly provide timing and alarms to the system A CAUTION The following procedures are destructive to DS1 data and should not be attempted while DS1 facilities are active Task List Test Stratum 3 Clock 1 Check for Red LEDs 2 Verify Timing to the System Check for Red LEDs Begin Return to Task List 1 Turn on the Stratum 3 clock and wait 40 50 seconds to allow the system to complete the on board diagnostics before checking LEDs 2 If there are any red LEDs follow the procedures in Stratum 3 Clock LED Indicators Stratum 3 Clock LED Indicators LED Label Procedure REF Check that the Cl circuit pack on the left is inserted properly Card PAI PAI PAI PAI Cl ST3 ST3 ST3 Check wiring for DS1 in carrier A which connects the system to the CSU and the External Synchronization Clock at the MDF through a Y cable assembly If all else fails to clear the LED then replace the circuit pack REF B Check that the CI circuit pack on the right is inserted properly Check wiring for DS1 in carrier B which connects the system to the CSU and the External Synchronization Clock at the MDF through a Y cable assembly If all else fails to clear the LED then replace the circuit pack STA Replace the ST3 card STB Replace the ST3 card FAIL Check wiring for its associated DS1 reference and replace the circuit pack if necessary FAIL Replace the circuit pack LOCK Ignore
389. sed Not Used Not Used Not Used 158 Definition Rectifier Failure positive Rectifier Failure negative AC Failure positive AC Failure negative Battery Interface Failure positive Battery Interface Failure negative Battery On Discharge positive Battery On Discharge negative Receive Data Transmit Data Data Terminal Ready RS 232 Ground Data Set Ready Request To Send External Alarm Connector Pinout Pin Designation Definition 48 Not Used 23 Not Used 49 Not Used 24 Not Used 50 Not Used 25 Not Used Port Circuit Pack and Telephone Pin Designations Pin on 4 wire 2 wire 8510T Analog NT1 Z3A1 amp Modular 302C1 302C1 Basic Station Z3A2 Plug 8400 Series 8400 Series Rate Modem Asynchro 603E 9403 603E 9403 Interface nous Data 9434 9410 9434 BRI Units with ADU adjunct Data speaker Module phone 1 TXT TXT 2 TXR TXR 3 PXT TXT PXT 4 T PXR 5 R PXT No 6 PXR TXR PXR 7 48VDC 48VDC 48VDC modular 48VDC 8 GRD GRD GRD jack GRD Circuit TN754 4 wire TN2181 TN556 TN2183 TN2198 TN726 Pack digital 8 port 2 wire digital ISDN BRI Analog line 2 wire Data Line 16 port Line 16 port Basic TN2224 Rate 2 wire digital Interface 24 port line PX PBX transmitT Tip A TX Terminal transmitRRing B Return to Task List Remote Network Interface Return to Task List 159 The Remote Network Interface formerly Initialization and Administration System INADS provides a
390. sfer panel Install Telephones Used Only for Emergency Transfer Trunk Auxiliary Field Install Telephones Used for Emergency Transfer and as Normal Extension Trunk Auxiliary Field 808A Emergency Transfer Panel EMERGENCY TRANSFER PANEL TRUNK TEST SWITCHES CIRCUIT GROUI 3 BOTH SWITCHES MUST BE THROWN TO ACTIVATE 8 gt 4 TRUNK OPTION NORMAL ACTIVATED OPERATION lt TRUNK IDENTIFICATION led808a LJK 040896 Figure Notes 1 808A Emergency Transfer Panel 2 Circuit Start Selection Switches 169 3 Trunk Identification Label 4 25 Pair Male Connector 808A Emergency Transfer Panel Mounting 808a_em LJK 042396 Figure Notes 1 808A Emergency Transfer Panel 2 Ear for Screw Mount 3 Cut Out for Snap Mount 4 25 Pair Male Connector 5 Circuit Start Switches Install the 808A Emergency Transfer panel Begin Return to Task List Note The 808A must be installed in a location that can be accessed only by authorized personnel The location must meet standard environmental considerations such as temperature humidity and so forth 1 Verify dial tone is present at each trunk circuit 2 Locate the circuit start selection switches see 808A Emergency Transfer Panel These are the first 10 two position switches on the left side of the Emergency Transfer Panel They are used to set each of the fi
391. shows the 127A BALUN coaxial adapter Note Although the TN1654 DS1 converter supports 75 ohms use the 127A BALUN to convert the 120 ohms to 75 ohms rather than the switch settings Note Set Circuit Pack Switches 1654 DS1 Converter shows a typical connection DS1 Converter Circuit Pack Switches OOSSSS9ggg 9 R DEN SOowv uw a nn 4 S N N la fxr j fz ckdfds1 KLC 091499 TN1654 DS1 Converter Switch Functions Switch Function 1 Type of Facility 2 Span A Line Impedance E1 Only Span A Framing T1 Only 3 Span B Line Impedance E1 Only Span B Framing T1 Only 306 TN1654 DS1 Converter Switch Functions Switch Function 4 Span C Line Impedance E1 Only Span C Framing T1 Only 5 Span D Line Impedance E1 Only Span D Framing T1 Only 6 Force Fiber Data Stream Scrambling TN1654 DS1 Converter Switch Settings 1 2 3 4 5 6 up T1 1200hms 1200hms 1200hms 1200hms_ Enabled ESF ESF ESF ESF down E1 750hms 750hms 750hms 750hms Disabled D4 D4 D4 D4 1 Although the TN1654 circuit pack supports 75 ohms use the 127A BALUN to convert the 120 ohms to 75 ohms rather than the switch settings see 75 ohm E1 Interface Cabling 127A BALUN Coaxial Adapter hidf127b 012301 Figure Notes 1 127A BALUN coaxial adapter 2 Connect to quad cable H600 348 or similar 3 BCN Connections to E1
392. slation information in memory and write it to the translation cards 3 Update backup translation cards if required Add Packet Bus Support Return to Task List You may need to add packet bus support when adding ISDN BRI or CallVisor ASAI port circuit packs 219 Note Installing TN570 expansion interface circuit packs as part of adding packet bus support requires a service interruption Give the customer advance notice of the scheduled addition Task List Add Packet Bus Support e Disable Alarm Origination Packet Bus Support Save Translations Packet Bus Support e Power Down Cabinet Packet Bus Support e Install Circuit Packs Packet Bus Support e Power Up System Packet Bus Support e Test the Packet Bus and C LAN Circuit Pack Packet Bus Support e Resolve Alarms Packet Bus Support e Enable Scheduled Maintenance and Alarm Notification Packet Bus Support e Save Translations Packet Bus Support If installing TN570 Expansion Interface circuit packs as part of adding packet bus support then service is interrupted Notify the customer in advance as to when the addition will be carried out If not installing TN570 circuit packs then service is not interrupted and you can skip to Install Circuit Packs Packet Bus Support Disable Alarm Origination Packet Bus Support Begin Return to Task List 1 Type change system parameters maintenance and press Enter 2 Set the Alarm Origination Activated field
393. ssary isolation between the system and the clock The Y cable plugs directly into the CSU and connects to standard cables for interface to the system and the yellow field on the MDF The H600 307 cable connects the system end of the Y cable to a DS1 circuit pack shown as TN464 2464 TN722 or TN767 The B25A cable connects the clock end of the Y cable to the yellow field on the MDF Typical Connections to Stratum 3 Clock 320 eee cyd st3 LJK 101596 Figure Notes 1 SCC1 Cabinet PPN 2 A Position 3 Position 4 H600 307 Cable b H600 247 G2 Cable 6 1300 Feet 396 m 7 B25A Male to Female Cable 8 Channel Service Unit Secondary 9 Channel Service Unit Primary 10 Stratum 3 Clock 11 Main Distribution Frame MDF 12 DS1 E1 Interface Circuit Pack 13 DS1 Tie Trunk Circuit Pack 14 DS1 Interface Circuit Pack 15 Tone Clock Circuit Pack Return to Task List 321 Install the Stratum 3 Clock Wiring Begin 1 Return to Task List Connect the B25A cables from the TN780 connector panel slot on the system cabinet and the Stratum 3 Clock to the cross connect module in the yellow field Connect the CSU plug end of the H 600 274 Y cable to the primary CSU Route an H600 307 cable from the DS1 connector panel slot on the system cabinet to the
394. ssing Element Interchange Test Terminating Trunk Transmission Test the C LAN Connection Test Stratum 3 Clock if used Perform Complete System Test and Resolve Alarms 21 Activate and Test Alarm Origination Feature Nj mk iE O O A Make Test Calls Begin Return to Task List Make 2 calls from 1 telephone to another telephone Make the first call by dialing a telephone and make the second call by dialing a trunk access code and a Listed Directory Number LDN 355 Test 302C Attendant Console Begin Return to Task List Check all lamps are operational and call another telephone in the system 1 Simultaneously press and hold the Ringer Volume up button and the POS BUSY button This puts the console in the self test mode Note Releasing the buttons returns the console to normal mode 2 Verify all lamps on display light and remain lighted Each row of lamps on the console lights and goes dark in sequence from top to bottom 3 Press Start and listen for dial tone 4 The green lamp associated with Idle Call Appearance lights up The Position Available lamp goes dark 5 Dial number associated with a working telephone Audible ringing tone is heard in ear piece 6 Press Release Audible ringing tone is silenced The green lamp associated with idle call appearance button goes dark The Position Available lamp lights Return to Task List Test Selector Console Begin Return to Task List
395. st configuration all and press Enter to determine if the new circuit pack appears in the correct slot and that there are no circuit pack conflicts External Modem Pass Thru Kit Equipment 0 42 indakit2 EWS 091498 Figure Notes 1 Pass thru Tool 2 Machine Screw 3 Cable Tie 4 Panel Adapter Bracket 5 Cable Assembly 6 Cable Tie Mount Parts List Quantity Description 1 External modem pass thru kit Kit includes pass thru tool cable ties panel adapter bracket machine screws and cable tie mounts 1 Cable Assembly Remove the Fan Cover 331 Attach the Panel Adapter Bracket Attach the Cable Assembly to the Bracket SS e prda0003 EWS 090498 Attach the Cable to the Pass Thru Tool fodacup3 EWS 0825 Figure Notes 1 Pass thru Tool 2 RJ45 Telephone Plug 3 Tie Wrap 333 Insert the Pass thru Tool Replace the Fan Cover Connect the Cable to the TN1648B Circuit Pack Prda0011 KLC 091698 Return to Task List Add Modem Pooling Retur
396. stallation Note The type of power required is shown on the cabinet s rear door Grounding an AC Powered System J58890CE Grounding is relatively simple for an AC powered system Basically the cabinets connect to the single point ground terminal block located at either the AC load center or to a separate single point ground block wired to the AC load center or optional AC protector cabinet The approved ground wire must be a green or green with yellow stripe 6 AWG 40 16 copper stranded wire Bond all approved grounds at the single point ground to form a single grounding electrode system Ground AC Load Center 50 ft 15 2 m or Less from Cabinet Begin Return to Task List 1 At the bottom rear of the PPN cabinet connect a 6 AWG 40 16 mm CABINET GROUND wire to the cabinet ground terminal block See Typical Cabinet Ground Location 2 Route the CABINET GROUND wire to the single point ground block at the AC load center and connect 3 At the bottom rear of the first EPN cabinet if provided connect a 6 AWG 40 16 mm CABINET GROUND wire to the cabinet ground terminal block 4 Route the CABINET GROUND wire to the single point ground block at the AC load center and connect Note If the EPN cabinet is located remote from the PPN cabinet in a separate room or building connect the CABINET GROUND wire to an approved ground 5 Repeat connecting each EPN cabinet to the single point ground block
397. status LED associated with the assigned button is in a steady state The LED may be turned off by pressing the button associated with the LED If the LED is off and the alarm has not been resolved by the time maintenance reschedules testing the green status LED resumes its steady state Circuit Pack LEDs Typically each circuit pack has 3 LEDs on the front panel The Circuit Pack LEDs table describes the red green and yellow LEDs and their meaning Also see Circuit Pack LEDs on Faceplate DS1 Converter Circuit Pack LEDs Eleven LEDs provide an indication of the state of the TN1654 DS1 Converter Circuit Pack LEDs and the T1 E1 facilities The top group has the standard red green and yellow LEDs The red LED indicates an alarm condition and the green 126 SPAN LEDs LED indicates testing in progress The 4 SPAN LEDs indicate the status of the T1 E1 facilities The four STATUS LEDs are currently unused and remain off The yellow LED is used to indicate the state of the fiber interface the fiber channel the control channel and the communications link to the SPE in the following manner and order of priority See DS1 Converter Yellow LED Flashing States The 4 SPAN LEDs indicate the status of the 4 T1 E1 facilities A SPAN LED is in one of the following states 1 Solid on yellow Facility is operational and alarm free 2 Blinking yellow for 2 seconds off 0 1 seconds Facility is operational and alarm free AND is carrying the con
398. system memory from the translation card by entering the restore announcements command Task List Add Multiple Announcement Circuit Packs e Replace a TN750 or TN750B with a TN750C or Move all Announcements from a TN750B to a TN750C Add additional TN750C Circuit Packs Adda TN2501AP Announcement Circuit Pack e Move a Single Announcement from one Announcement Circuit Pack to another Replace a TN750 or TN750B with a TN750C or Move all Announcements from a TN750B to a TN750C Begin Return to Task List Note Do not copy or restore announcements from a TN750C to a TN750 or TN750B circuit pack as this may corrupt the announcement data 1 Save announcements from the TN750 B to the mass storage system 2 Insert the TN750C circuit pack into a vacant slot of a carrier Any carrier is acceptable since power holdover is not a concern 214 10 Lift the locking lever upward until the latch pin engages Administer a new data module on the TN750C circuit pack as described in Administrator s Guide for Avaya Communication Manager Type restore announcements and press Enter to the TN750C circuit pack equipment location Wait until announcements copy from voice RAM to flash memory yellow LED on the TN750C stops flashing This may take about 10 minutes Type busyout board 01c11 and press Enter for the TN750 B circuit pack where 01c11 is an example circuit pack location Type change integrated announcements and press Enter
399. t remove the cover from the top rear of the unit remove the mode select circuit board and turn it around replace the cover and connect the power cord The unit performs a self test Note The power LED must be steady on If the power LED is blinking the data module is not communicating with the Avaya Media Gateway Check the wiring at the MDF wall jacks and data module Return to Task List Add a Data Module to the Switch Begin Return to Task List 1 Add the data module administratively to the switch by typing add data module number or add data module next and pressing Enter 2 Inthe Type field type pdm and press Enter 3 In the Port field type the location of the digital line circuit pack connected to the data module for example 01 1503 4 f system access ports and hunt groups have not been set up set them up Refer to the Administrator s Guide for Avaya MultiVantage Software Return to Task List Test Data Module Hardware Connections Begin Return to Task List 101 Find your data module in the table below and follow the instructions for testing and troubleshooting it Type of Data Module 8400B 7400B 7400A Return to Task List How to Test and Troubleshoot The red LED should be steady on If the red and green LEDs are blinking the unit is not communicating with the Avaya Media Gateway Check the wiring at the MDF wall jack and the 8400B The Power and TR LEDs should be st
400. t correctly Use one of these installation methods Direct connection between the switch and REA No connection between the switch and RFA Retrieve the RFA License File with both serial numbers from the RFA Application If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints Type set time and press Enter Ensure that the system date and time are set correctly For duplicated systems only type status system all and press Enter 228 Ensure that the standby SPE is notin the maintenance state If it is wait for the maintenance state to finish 5 Use one of these installation methods Direct connection between the switch and RFA No connection between the switch and REA Direct connection between the switch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File Note This procedure sends the License File to the switch and installs it 2 If the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints No connection between the switch and RFA 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File to your laptop PC 2 Open
401. t the new settings 243 IP Interfaces Screen change ip interfaces Page 1 of 2 IP INTERFACES Inter region IP connectivity allowed n Enable Net Eth Pt Type Slot Code Sfx Node Name Subnet Mask Gateway Address Rgn y C LAN 01A09 TN799 B clan al 255 255 255 0 1 1 255 255 255 0 192 168 10 21 1 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 n 255 255 255 0 Return to Task List Remove the Circuit Packs Begin Return to Task List A CAUTION When adding or replacing any hardware be sure to ground yourself against electrostatic discharge ESD by wearing a grounded wrist strap Note The TN799 and TN2302AP circuit packs are hot swappable so you do not need to power down the carrier to remove or install them Note If replacing the existing TN799 circuit pack remove it first and replace it with the new TN799DP 1 Press the recessed Reset button on the TN802B circuit pack until MSHUT starts flashing on the LCD When MSHUT is in a steady state it is safe to remove the circuit pack 2 Remove the TN799 and TN802B circuit packs Return to Task List 244 Replace the Cables Begin Ret
402. t transmission and power The BR851 B is an 8 pin device with a single plug and two jacks See Wiring Diagram of BR851 B 367A Adapter The 367A is an 8 conductor adapter used at the work location to bridge 3 to 7 terminals See Wiring Diagram of 367A Adapter Wiring Diagram of BR851 B 9 5 21 9 e T possess 323 m 555 J 655 pa QUPD RUM Ir o 9 Figure Notes 1 Wire Pairs 2 Pin Numbers 3 Modular Plug Male 4 Female 5 Two 8 pin Modular Jacks 6 T Type Adapter Wiring Diagram of 367A Adapter 207 eeeeeee cccccce 0000000 BE 0000000 0000000 0000000 000000 87654321 87654321 87654321 19 JJ hus b 9 9 9 Figure Notes 1 Jack 1 2 Jack 2 3 Jack 8 4 367A Adapter Basic Multipoint Installation Distances Basic Multipoint with One Work Location provides cabling information for fanout of ISDN BRI multipoint installations In this illustration the terminating resistor is located in the satellite closet All distances assume 24 AWG 5 0 5 mm D Inside Wire DIW Basic Multipoint with One Work Location npo prr inst dis CJL 030796 Figure Notes 1 S Interface Source TN556 2
403. tallic surface exposed to the exterior soil Concrete Encased Ground An electrode encased by at least 2 in 5 1 cm of concrete and located within and near the bottom of a concrete foundation or footing in direct contact with the earth The electrode must be at least 20 ft 6 1 m of 1 or more steel reinforcing bars or rods 1 2 in 1 3 cm in diameter or at least 20 ft 6 1 m of bare solid copper 4 AWG 26 mm wire Ground Ring A buried ground that encircles a building or structure at a depth of at least 2 5 ft 0 76 m below the earth s surface The ground ring must be at least 20 ft 6 1 m of 2 AWG 35 mm bare copper wire Approved Floor Grounds Approved floor grounds are those grounds on each floor of a high rise building suitable for connection to the ground terminal in the riser closet and to the cabinet equipment single point ground terminal Approved floor grounds may include the following e Building steel The grounding conductor for the secondary side of the power transformer feeding the floor e Metallic water pipes Power feed metallic conduit supplying panel boards on the floor A grounding point specifically provided in the building for the purpose WARNING If the approved ground or approved floor ground can only be accessed inside a dedicated power equipment room then connections to this ground should be made by a licensed electrician 383 384 Connecting and Handling Fiber Optic
404. te Insert a pencil or marker through the holes previously occupied by the carriage bolts front and rear in the bottom of the cabinets and mark the raised floor panels directly beneath each hole Roll the cabinet out of the way and drill 4 holes 5 8 in 1 6 cm in diameter through the raised floor panels marked in Step 2 A CAUTION Take care while drilling the holes through the raised floor that the drill bit does not penetrate any cables below the floor that could cause damage to the cable or injury to the installer 4 10 Insert long punch through the holes drilled in Step 3 and mark the concrete floor beneath the raised floor panels Remove the raised floor panels in which the holes were drilled Using 1 2 in 1 3 cm anchor bits drill a hole at each of the locations marked in Step 4 Stop drilling when the mark on the side of the bit reaches the floor level Insert a concrete floor anchor STARR part number 3425 into the hole until the mark on the bit reaches floor level again Snap the top of the anchor bit off Repeat for the remaining holes A 3 8 16 threaded rod is used to secure the cabinet to each concrete floor anchor See Earthquake Mounting Raised Computer Floor Measure the distance from 1 of the anchors to the bottom of the cabinet Add 1 2 in 1 3 cm to this measurement to allow the rod to be threaded into the floor anchor Add an additional 1 2 in 1 3 cm to allow the rod to protrude
405. te For IP trunks see Add IP Solutions Task List Add Trunks Install CAMA E911 Trunk with a separate task list Install ISDN PRI Trunks with a separate task list Adding CO FX WATS and PCOL Trunks Adding DID Trunks Adding Tie Trunks Add DS1 Tie and OPS Trunks with a separate task list Adding Japanese 2 Mbit Trunks Add TN1654 DS1 Converter r only with a separate task list Install CAMA E911 Trunk Return to Task List The CAMA E911 feature requires the TN429C D CO trunk circuit packs or later suffix Port Networks PNs that include TN429C circuit packs used to interface to CAMA trunks require some CPTR resources to be either TN744D V2 or TN2182B circuit packs since TTR CPTR or General Purpose Tone Receiver GPTR resources are selected from the pool available in the PN when needed Compatibility Tone Clock TTR CPTR and GPTR Circuit Packs denotes which of these circuit packs are compatible and which are not affected Task List Installing CAMA E911 Trunks 1 Installing the Circuit Pack 2 Adding the Trunks 3 Changing the Feature Access Code 4 Changing the ARS Digit Analysis 5 Changing the Route Patterns 6 Changing the CAMA Numbering and Class of Restriction Return to Task List Compatibility Tone Clock TTR CPTR and GPTR Circuit Packs Circuit Pack TN744 TN744B TN744C TN744DV1 TN744DV2 TN748C TN748D Description Call Classifier Detector Call Classifier Detector Touch Ton
406. tel product uses N3 to provide similar functionality 327 SCC1 Modem Fields Field Misc Init Param Auto Answer Ring Number Dial Type Adjustable Make Break Ratio Dial Command No Answer Time Out Description This field has a 20 character blank default and supports any initialization parameters not already specified The AT commands specified in this field are always the last initialization parameters to be sent to the external modem This field is not case sensitive This field controls the number of rings required before the modem answers an incoming call This field should be set to SO 10 This field controls the type of interregister signaling used between the modem and the CO This 3 character field is denoted by T for tone dialing default and P for pulse dialing This setting depends on type of line tone or pulse to the modem This field controls the make break ratios of pulses and DTMF dialing Most modems have support for different make break options for pulse dialing only Paradyne Intel and U S Robotics use the default amp PO to select a ratio of 3996 make and 6196 break for communication for the United States and Canada The option amp P1 sets a ratio of 3396 make and 6796 break for the United Kingdom and Hong Kong This is a 5 character blank field default and is not case sensitive This field has a default of in a 3 character field This field denotes the standard dialing comm
407. tending 4 Pair Station Cables Double modular plug ended 4 pair station cable Use this cable to provide nonstandard length runs between adapters and information outlets with push on connections It can also be used between adapters and modularly connected information outlets It is available in the same lengths as the single modular plug ended cable Bulk Cable Same as the 25 pair cable or multiple 25 pair cable however the bulk cable is not equipped with connectors Use this cable between the equipment room and satellite closets when both are equipped with punch down type terminal connecting blocks 4 pair station cable Use this cable when 4 pair station cables are to be field terminated on the 110 type terminal blocks in the equipment room or satellite closet and the information outlets require push on connections 62 Closets Site Locations Satellite Locations Site locations are closets that provide a point in the station wiring for the administration of remote powering Adapters are used at site locations to terminate the 25 pair station cables and provide connection points modular jacks for power adapters and 4 pair station cables The258A and BR2580A adapters plug into a 25 pair female cable connector These adapters divide the 25 pair cable into six 4 pair modular jack circuits See 258A and BR2580A Adapters The 356A adapter plugs into a 25 pair female cable connector See 356A Adapter The 356A adapter divid
408. ter TN464GP TN2464BP Add IP Solutions Donnea the et e e eui M Connect the Ethernet iori ur dog ecd Ak ed Law 21 Admit Admini Test ind Install the Circuit P 11 Trouble jooting firmware downl Test Telephones and Other Equipment 355 Option Switch anes Module Option Switch Settings ea ck aw ae 986 About DCS Switch aria 370 374 UE aE pe E External Modem Printer enin Set Approved Grounds 383 Approved Floor Grounds pu RE E Connecting and Handling Fiber Optie c Cables 385 LASER POMCI XXER4P Detailed Information oes oe mE eee ee Lanes ere ene 385 Optical Cross Connect Hardware 385 100A Lightguide Interconnect Unit PPP Atk A Gs 10A Lightguide Connector Panel and Cousins readin aee ea e D Lig tguide Troughs 4 soss sac eta oe Ree eae Ba oe 986 iber rc 389 389 389 Labels hi r Fiber Optic Cables unos m x x oe mo eee aS om ow BOO 13 Cleaning Fiber Optic Cables 390 Install Fiber Optic Cable Pass Thru Kit for MCC1 Cabinets 391 291 vx 391 us 995 402 403 403 403 s 404 ring PNC Duplication Ntc dri dien e dr dete di e dome s RUE W iwi ned Mardi
409. tes 1 Connect small battery holdover cable or temperature sensor cable from large battery cabinet to J20 2 Carrier Circuit Breakers 3 Ground Terminal Block 4 Connect 48 VDC Return 1 AWG 50 mm red cable here 5 Connect 48 VDC 1 AWG 50 mm black cable 6 1 AWG 50 mm 50 ft 15 2 m cable to large battery cabinet For cables greater than 50 ft 15 2 m contact your Avaya representative 7 Ground Terminal Block 8 To AC load center or approved single point ground block Typical Cabinet Grounding Wiring Diagram 35 widfspgb 100297 Figure Notes 1 PPN Cabinet 2 EPN Cabinet if Installed 3 6 AWG 40 16 mm2 CABINET GROUND Wire 4 Single Point Ground Block 5 6 AWG 40 16 4 mm2 Ground Wire to Approved Ground 6 AC Load Center Single Point Ground 7 Over 50 ft 15 2 m 8 Cabinet Ground Terminal Block Return to Task List Install Coupled Bonding Conductor Wires Begin Return to Task List This is a conductor that connects to the single point ground block and run adjacent to pairs in an associated cable The mutual coupling between the CBC and the pairs reduces potential differences in terminating equipment The conductor consists of a 10 AWG 25 6 mm wire terminated at the CBC ground terminal bar at the Main Distribution Frame MDF 1 At the DC Power Cabinet connect a 10 AWG 25 6 mm ground wir
410. the 4 pair station circuits are run from the satellite locations to the information outlets This section has information about 4 Pair Station Circuits 3 Pair to 4 Pair Station Circuit Distribution Lists of terminals that can be connected to the system are provided in e Voice and Data Terminals Connectable Administration Terminals 4 Pair Station Circuits Four pair circuits can be run directly from an equipment room MDF to a 258A or BR2580A adapter as shown in 4 Pair Circuit Distribution and Connectivity The 4 pair station cables connect the adapter to the information outlets The 4 pair station cables can be run directly from the equipment room to the information outlets if 4 pair terminal blocks are used in the distribution field See 4 Pair 65 Run to Equipment Room or Satellite Location The station cables must be field terminated on the 110 type terminal blocks If 110 type terminal blocks are used with a modular plug ended station cable an adapter can be connected directly to the 110 type terminal block connectors See 4 Pair Run to Equipment Room or Satellite Location 3 Pair to 4 Pair Station Circuit Distribution 3 Pair to 4 Pair Satellite Location Connectivity shows the 3 pair circuit distribution from an equipment room MDF to a satellite location using 110 type hardware Four pair circuits are distributed from the satellite location to the information outlets Three pair circuits can also be run dir
411. the LC terminals on the yellow emergency transfer row connecting block for each telephone 5 Connect ST leads on the yellow emergency transfer row connecting block for each emergency transfer telephone to the assigned terminal in the blue or white station distribution field 6 Install the telephone Connect telephone to the information outlet Install patch cords jumper wires between the system side and the station side of the station distribution field on the MDF Connections for Telephone Used for Emergency Transfer and as Normal Extension 10 Hle d 2820 ST Ew ST Ew LLH mue BE m 8 8 5 i 6m 6 Em7 0 8 08 8 28 LEELEE refer tetee tetee 1M 1m 2M 2m BM 3m 3w ALARM MONITORS EM TRANS RELAY PWR ERE EE PEE Se ee eee ee ee 0 eee eee eee 1758582b 042996 Figure Notes 1 To Network Interface Facility 2 To Blue or White Station Distribution Field 3 To TN2183 or Equivalent Analog Line Circuit Pack 4 To TN747 or Equivalent Central Office Trunk Circuit Pack 5 To Power Transfer Unit 6 To Control Carrier AUX Connector Return to Task List Install External Ringing Begin Return to Task List IZT Connections for external ringing are at an information outlet The system side of the Main Distribution Frame MDF is connected to a TN2183 or equivalent Analog Line
412. the alarm log Resolve any alarms using the Maintenance for Avaya MultiVantage DEFINITY Server documentation Save Translations ISDN BRI Begin Return to Task List 1 If the system is high or critical reliability status system 1 and press Enter to verify that the system is in the active standby mode 2 Type save translation and press Enter This instructs the system to take all translation information in memory and write it to the translation cards 3 If the system contains a TN750 B C Announcement circuit pack type list configuration software version and press Enter To restore these announcements type restore announcements and press Enter 4 Update backup cards if required Add a TN2501AP Announcement Circuit Pack Return to Task List Note To install a TN2501AP you must ensure the system is enabled for TN2510AP VAL boards If the Maximum VAL boards field on the Customer Options screen is set to 0 then you need to obtain and install a new license file before you can install the card Installing the pack includes 1 Verifying the required hardware 2 Installing the TN2501AP circuit pack 3 Configuring the system for the TN2501AP Verifying the required hardware Begin Ensure that you have the required hardware TN2501AP circuit pack Backplane adapter LAN cable Installing the TN2501AP circuit pack Begin WARNING To prevent electrostatic discharge ESD be sure to wear a gr
413. the cables Plan the use of cable ties to avoid crimping the cable or creating a fixed stress point where at a later time movement of the cable causes it to exceed the minimum bend radius 12 Close the rear door A CAUTION Be careful not to crimp the fiber cable when you replace the fan cover 13 Replace the fan cover See Replace the fan cover 14 Connect the fiber cable to the angled connector on the front of the circuit pack See Connect fiber cable to circuit pack Note Dress the fiber optic cable straight down the front of the circuit pack Do not allow the cable to cross in front of another circuit pack 15 Dress the cable using the supplied cable ties and cable tie mounts See Dress the cable 16 If a circuit pack was removed in the previous procedure to access 2 open slots replace the circuit pack into its original slot 17 Close the front door 18 Discard the pass thru tool Return to Task List Fiber optic adapter and pass thru tool 396 dafocoup RPY 062497 Figure Notes 1 Pass thru Tool 2 Beige SC SC Fiber Optic Adapter Insert the pass thru tool Icda2fop RPY 021098 397 Fiber Optic Cable and Adapter TN A A EEF Icda6fop RPY 02169
414. the duplicate fiber link Endpoint 1 s duplicate along with Endpoint 2 s duplicate make up the duplicate fiber link called the B PNC link DS1CONV Board Type Display only field showing the type of 051 Converter circuit pack in Endpoint 1 The circuit pack type in Endpoint 1 A PNC and Endpoint 1 B PNC must be the same This field is updated via the Change Circuit packs command Board Location Enter the cabinet carrier and slot that identifies the physical location of a circuit pack in the second endpoint of the duplicate fiber link Endpoint 2 s duplicate along with Endpoint 1 s duplicate make up the duplicate fiber link called the B PNC link Board Type Display only field showing the type of circuit pack in Endpoint 2 The circuit pack type in Endpoint 2 A PNC and Endpoint 2 B PNC must be the same DS1CONV Board Location Enter the cabinet carrier and slot that identifies the physical location of DS1 Converter circuit pack in the second endpoint of the duplicate fiber link Endpoint 2 s duplicate along with Endpoint 1 s duplicate make up the duplicate fiber link called the B PNC link e DS1CONV Board Type Display only field showing the type of DS1 Converter circuit pack in Endpoint 2 The circuit pack type in Endpoint 2 A PNC and Endpoint 2 B PNC must be the same This field is updated via the Change Circuit packs command Fiber Link Administration form page 1 of 3 406 fiber link next Fi
415. the line compensation 1 to 5 in the A B C and D columns under the DS1 Converter Facilities heading for each DS1 facility connected to ENDPOINT 2 see Distance to DSX 1 Interface feet The 051 line signal is pre equalized at the transmitter so that DS1 line pulses are the correct amplitude and shape when they reach the Network Interface The amount of equalization necessary is determined by the distance to the Network Interface when the endpoint supplies a DSX 1 interface and also by the type of wiring used to connect to the Network Interface The types of wiring allowed are 22 gauge ABAM shielded twisted pair cable 24 gauge Premises Distribution System PDS wiring and 26 gauge PDS wiring e Facility A Circuit ID Displays when the value in Facility Installed for Facility A is yes Enter up to 40 characters to identify the cabinet carrier and slot of the DS1 Converter circuit pack s physical location Similarly Facility B Circuit ID Facility C Circuit ID and Facility D Circuit ID fields display for each of the DS1 Converter Facilities when yes is entered in the corresponding Facility Installed field Fiber Link Administration form for TN574 Circuit Pack DS1 Converter Complex Administration page 2 of 3 m fiber link next Page 2 of 3 N FIBER LINK ADMINISTRATION A PNC 051 CONVERTER DS1CONV ATTRIBUTES DS1CONV Board Location 01B01 DS1CONV Board Location 02B01 DS1CONV Board Type TN574 DS1CONV Board Type TN574 DS
416. the same for most of the Avaya Media Gateway telephones and other equipment This task list provides wiring examples of similar installation procedures These are examples only actual wiring procedures may vary at each site After installing the hardware the data for telephone features must be administered These procedures are provided in the Administrators Guide for Avaya Communication Manager Note Refer to nstallation for Adjuncts and Peripherals for Avaya Communication Managerto install the necessary peripheral equipment Task List Wiring Examples and Wiring Procedures e Voice and Data Terminals Analog Tie Trunk Example Digital Tie Trunk Example e DS1 Tie Trunk Example Auxiliary Connector Outputs Three Pair and Four Pair Modularity e Adjunct Power Connection Locations Attendant Console Example e Connect External Alarm Indicators and Auxiliary Power Connect Power Distribution Unit External Alarm Wires Remote Network Interface e Off Premises or Out of Building Stations Emergency Transfer Units and Associated Telephones 808A Emergency Transfer Panel and Telephone Installation Examples Install External Ringing Install the Queue Warning Indicator These links provide useful reference information Voice and Data Terminals e Circuit Pack and Auxiliary Equipment Classifications Connector and Cable Diagrams Pinout Charts Voice and Data Terminals Return to Task List
417. tive PE should be the B processor for this test and the interchange should make PE A the active PE Verify the system can successfully perform a PE interchange 1 At the management terminal verify the screen displays PE B in the upper right corner 2 Type check status and press Enter Verify PE B is in the standby mode If it is proceed to Step 4 If it is not proceed to Step 3 3 Type refresh spr standby and press Enter 4 Type reset system interchange and press Enter The management terminal will be logged off and a beep will be heard 5 Login and verify that the screen displays PE A in the upper right corner Note Processor A s yellow light is on and its green LED is off Processor B s yellow and green LEDs are off The system is alarm free 6 Make system test call The call must complete and the conversation must be satisfactory Return to Task List 359 Test Terminating Trunk Transmission Begin Return to Task List The Terminating Trunk Transmission Test provides for extension number access to 3 tone sequences that can be used for trunk transmission testing from the distant end of the trunks The 3 test types must have extension numbers assigned on the system parameters maintenance form Test Type 100 Test Type 102 Test Type 105 Test Type Test Features Test type 100 5 5 seconds of 1004 Hz tone at 0 dB Quiet until disconnect disconnect is forced after 1 minute Test Type 102 9 seconds of 1004 Hz tone at 0 dB
418. to 1 of an assortment of non US DID trunk circuit packs 1 Determine the port assignment of the trunk from Trunk Group form 296 2 See Wiring Off Premises Stations 1654 DS1 Converter and install a DID trunk circuit pack in assigned carrier slot if an additional circuit pack is required 3 Administer DID Trunk Group screens in Administrator s Guide for Avaya Communication Manager Return to Task List Adding Tie Trunks Begin Return to Task List Each tie trunk connects to 1 port of a 4 port TN760 or to an assortment of non US tie trunk circuit packs 1 2 A Determine the port assignment of the trunk from Trunk Group form Install a TN760 or a non United States tie trunk circuit pack in the assigned carrier slot if an additional circuit pack is required For customer owned not leased tie trunk facilities such as campus environments TN760 circuit packs provide signaling capabilities beyond those specified by the industry wide E amp M standard Use Tie Trunk Circuit Packs Component Side and Tie Trunk Option Switch Settings and Administration to choose the preferred signaling format set switches on the TN760 circuit pack and administer the port Administer forms listed under Tie Trunk Group in Administrator s Guide for Avaya Communication Manager Tie Trunk Circuit Packs Component Side UNPROT o o o 4321 PROT 4 PORT 3 POR
419. to the translation card or removable media 3 If the PPN contains a TN750 Announcement circuit pack type list configuration software version and press Enter 4 If Page 2 of this form shows that recorded announcements were saved these announcements can be restored using the restore announcements command Type restore announcements and press Enter Return to Task List Resolve Alarms DS1 Tie and OPS Trunks Begin Return to Task List 1 See your record of customer busy outs and recreate the pre upgrade busy out states 2 Type display alarms and press ENTER 3 Examine the alarm log 4 Resolve any alarms using the appropriate Maintenance for Avaya MultiVantage and DEFINITY Server book Deliver or Install License file DS1 Tie and OPS Trunks Begin Return to Task List 302 New Duplicated G3r installations only New simplex and upgraded G3r only New or upgraded G3si only A CAUTION This procedure must be done immediately after you upgrade the software If the license file is not installed within 10 days the switch enters a No License mode and shuts down all call processing 1 2 1 Retrieve the RFA License File with both serial numbers from the RFA Application Type set time and press Enter Ensure that the system date and time are set correctly Use one of these installation methods Direct connection between the switch and RFA No connection between the switch and REA Type save translation an
420. tomer supplied device The relay can be administered to make contact when a major minor or warning alarm condition occurs in the system Trunk Cables Among Network Interface Sneak Fuse Panel and Cabinet The 1 pair of Central Office CO trunks are installed by the network provider in the green field Up to 24 pairs may be terminated on each row of the 110 type terminal block Tie trunks also appear in the green field with up to eight 3 pair trunks terminated on each row of the 110 type terminal block WP 90929 List 1 and 3 concentrator cables can be used to connect the cabinet to the 110 type terminal blocks in the purple field The 1 pair patch cords jumper wires are then run from the purple terminal block rows to the green terminal block rows in order to establish the correct 3 pair modularity Equipment Room Cabling Labels 9 e A ee 1 Purple Label Port Cable 2 Blue Yellow Label Building and Floor 3 Yellow Label Auxiliary 4 Blue Yellow Label Site or Satellite Equipment Room Labels Label Name Range Port Cable 1A1 1A20 1B1 1B20 1C1 1C20 1D1 1D20 1E1 1E20 Building Field Identified Floor Field Identified Auxiliary Cable Field Identified Site or Satellite A F and or Field Identified 58 Self Stick Label on 25 Pair Cable Connector 1A2 gg Ibdf25p LJK 101596 Cable Routing to Top Terminal Blocks 1758424b MMR 052996 Figure Notes 1 Main Distribut
421. trol channel facility A or B only 3 Solid on red Facility is alarmed 4 Solid off Facility is not administered or has been busied out LEDS on Standby Components In high and critical reliability systems duplicated components on standby usually have the yellow LEDs off with the following exceptions major minor and warning alarm LEDs on the SYSAM circuit pack on the standby SPE do not give reliable indications Note only LEDs on the active SYSAM circuit pack yellow LED blinks on and off when the standby processor circuit pack is up and standby maintenance is running In high reliability systems with a Center Stage Switch duplicated SPE simplex PNC the standby Switch Node clock s yellow LED is off In critical reliability systems the standby SNC is located on a separate carrier and normally remains lit Yellow LEDs on power units on standby carriers normally remain lit A CAUTION To prevent unnecessary trouble tickets do not enable the system alarms Alarm Origination feature until all installation and administration procedures are completed Circuit Pack LEDs LED Color Red Green Yellow Status Description Alarm The system has detected a fault in this circuit pack The alarm log should contain an on board alarm The red LED is also lit briefly when a circuit pack is inserted or reset If the circuit pack passes its initialization tests the LED goes out Testing
422. tton Note The DEFINITY AUDIX System takes about five minutes to shut down The heartbeat indication on the display continues to flash Manually Power Up AUDIX System 1 Using a pointed object such as a paper clip or a pen do not use a pencil press the Boot Shutdown button 2 Hold the Boot Shutdown button in until the display indicates the message BTEST steady on 3 Release the Boot Shutdown button The DEFINITY AUDIX System takes approximately five minutes to power up The display has the following sequence of steady on messages OSINIT OS AINIT ADX The DEFINITY AUDIX System is now powered up When the system is in the active state the display indicates ADX and the red LED is off Note Upon the system powering up the DEFINITY AUDIX System automatically reboots This sequence may show an MD or MJ ADX alarm in the display until the system has powered up When the system has completed its power up sequence the DEFINITY AUDIX System display reads ADX Access the System Return to Task List To access the system you first install Avaya Site Administration software on the PC and then connect to the Avaya Media Gateway Select the correct procedures for this installation from the task lists 95 Task List Access the system Install and Use Avaya Site Administration Connect Directly to the Avaya Media Gateway Connect Remotely to the Avaya Media Gateway Through a Data Module Connect Remotely to the Ava
423. uit packs unless otherwise noted T R PBX transmit voice Tip A Green T1 R1 PBX receive voice R Ring B Red M PBX transmit signal S Sleeve E PBX receive signal PX PBX transmit TX Terminal transmit LI LI Digital Trunk IN LO LO Digital Trunk OUT Lead and Color Designations Begin Cross Connect Color Amphenol Backplane Pin Pin Pin 1 W BL 26 102 2 BL W 01 002 3 W O 27 103 4 O W 02 003 5 W G 28 104 6 G W 03 004 7 W BR 29 105 8 BR W 04 005 9 W SL 30 106 10 SL W 05 006 11 R BL 31 107 12 BL R 06 007 13 R O 32 108 14 O R 07 008 15 R G 33 109 16 G R 08 009 17 R BR 34 110 18 BR R 09 010 419 Cross Connect Pin 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 420 Color R SL SL R BK BL BL BK BK O O BK BK G G BK BK BR BR BK BK SL SL BK Y BL BL Y Y O O Y Y G G Y Y BR BR Y Y SL SL Y V BL BL V V O O V V G G V V BR BR V V SL SL V Amphenol Pin 35 10 36 11 37 12 38 13 39 14 40 15 41 16 42 17 43 18 44 19 45 20 46 21 47 22 48 23 49 24 50 25 Backplane Pin 111 011 112 012 113 013 302 202 303 203 304 204 305 205 306 206 307 207 308 208 309 209 310 210 311 211 312 212 313 213 300 200 TN2185B ISDN BRI 4 wire S Interface Begin Port Signal 1 TXT 1 TXR 1 PXT 1 PXR 1 2 TXT 2 TXR 2 PXT 2 PXR 2 3 TXT 3 TXR 3 PXT 3 PXR 3 4 TXT 4 TXR 4
424. uncements on the circuit pack the following warning message appears WARNING This restore announcement command will overwrite the existing announcements on the specified board After 5 minutes with no alterations to the announcements the TN750C automatically copies the announcements from the Voice RAM to the internal flash memory The yellow LED on the front of the TN750C flashes You can only save the announcement contents of 1 circuit pack to mass storage at a time For the contents of every circuit pack save to separate translation cards Label each card to match the circuit pack saved to it TN750 and TN750B Announcement Circuit Packs Note The following save and restore procedures are only necessary for TN750 and TN750B announcement circuit packs The recorded announcements in the system can be saved on the mass storage system by typing save announcements spe active spe standby and pressing Enter These commands should only be used after business hours or when the System is operating during a low usage period The system takes about 40 minutes to transfer the recorded announcements from the announcement circuit pack to the mass storage system During this time period the management terminal cannot be used to administer the system until the transfer finishes however all other administration terminals if provided are allowed to perform administration procedures The recorded announcements in the system can be restored to
425. und Terminal Block 8 To AC load center or approved single point ground block Return to Task List Connect DC Power to PPN and EPN Cabinets Begin 1 2 Return to Task List Be sure the main circuit breaker is OFF Measure and cut 2 pieces of 1 AWG 70 44 wire long enough to reach from the DC Power Cabinet to the PPN cabinet At the DC Power Cabinet connect the 48 volt DC wire to the DC OUTPUT circuit breaker See Typical Power and Ground for a DC Powered Cabinet Connect the 48 volt RTN return wire to the ground discharge bar Route the wires out of the cabinet through the hole in the lower rear cover and to the PPN cabinet Connect the 48 volt DC wire to the 48VDC terminal on the J58890CF Power Distribution Unit Connect the 48 volt RTN wire to the 48RTN terminal on the J58890CF Power Distribution Unit terminal block 39 7 Repeat Steps 2 through 6 for each EPN and Auxiliary cabinet in the system Return to Task List Connect DC Battery Cabinet to DC Power Cabinet Begin Return to Task List Note The wire in the next step must be sized for a maximum voltage drop of 0 5 VDC in each leg of the DC distribution In this example 1 AWG is used 1 Turn off the main circuit breaker on the DC Battery Cabinet 2 Turn off the main circuit breaker on the DC Power Cabinet 3 Measure and cut a 6 AWG 40 16 mm wire long enough to reach from the DC Battery Cabinet s 48 Volt DC terminal to a
426. up protection and battery reliability replace batteries every four years 186 Follow all warnings and instructions marked on the products Clean products only with a dry rag Do not use this product near water For mounting security follow all installation instructions when mounting product Openings on top and bottom of power unit are provided for ventilation Do not block or cover these openings Do not exceed recommended environmental temperatures Operate these products only from the type of power source indicated on the product labels The power unit is equipped with a three wire grounding type plug a plug having a third grounding pin This plug will only fit into a grounding type power outlet This is a safety feature If you are unable to insert the plug into the outlet contact an electrician to replace the outlet Do not defeat the safety purpose of the grounding type plug Do not allow anything to rest on or spill into the products To reduce risk of fire and electrical shock do not overload power outlets Never push objects of any kind through the power supply or distribution unit slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electrical shock To reduce risk of electric shock do not disassemble these products Return them for repair when needed Opening or removing covers may expose you to dangerous voltages or other risks Incorrect reassembly can cause
427. urn to Task List 1 Disconnect the network cable from the Ethernet connection 2 Turn off the modem and unplug it from the AC outlet It is not needed for the TN2302AP 3 Disconnect the modem s RS232 port from the H600 512 external cable assembly From the rear of the cabinet 4 Disconnect the amphenol connector on the external cable assembly from the backplane connector corresponding to the TN802B circuit pack 5 Connect the amphenol connector on the TN2302AP Amphenol adapter to the backplane connector corresponding to slot selected for the TN2302AP circuit pack Note The TN802 circuit pack occupied 3 slots and the cable was connected to the rightmost slot For convenience use the same rightmost slot vacated by the TN802 circuit pack for the TN2302AP circuit pack The other 2 slots are now available for other circuit packs 6 Connect the network cable to the Ethernet connector on the TN2302AP Amphenol adapter Return to Task List Install the Circuit Packs Begin Return to Task List 1 If replacing the TN799 circuit pack install the TN799DP circuit pack in the slot vacated by the TN799 circuit pack 2 For convenience install the TN2302AP circuit pack in the rightmost slot vacated by the TN802 circuit pack The other 2 slots are now available for other circuit packs When you plug in the TN2302AP IP Media Processor the circuit pack starts to boot The RED LED stays on until an IP address is assigned to the circuit pack
428. usly installed unit Align the tabs and interlocks and snap the units together 3 Repeat Step 2 until all cable slack managers are installed Note Nine 1 4 in holes 0 63 cm are provided in a cable slack manager base if earthquake mounting is required If a base is mounted on an uneven floor shims may be required for leveling and to assure proper fit of the covers Holes are provided in the sides of the base for bolting cable slack manager together Bolts and shims must be obtained locally 4 The system cables will route through the cable slack manager as shown Complete cable routing is covered later in this chapter Cable clamps are required in installations with cable slack managers At the rear of the cabinets install 2 cable clamps using the screws provided These clamps hold the 25 pair input output or MDF cables in place Cable Routing Through Cable Slack Manager MCC1 and Cable Routing Through Cable Slack Manager SCC1 show cable clamp placement and cable routing Cable Routing Through Cable Slack Manager MCC1 cbdftlr CJL 102396 Figure Notes 1 Top of Cabinet 2 Cable Slack Manager 3 Cable Clamp 4 Spare Center Troughs 5 Cabinet Trough for Port Cables 84 Cable Routing Through Cable Slack Manager SCC1
429. ut Valid entries are five carrier and single carrier stack Default is blank Cabinet Type Display only field This field shows the type of cabinet being administered If cabinet 01 is being administered this field is processor If cabinets 02 through 44 are being administered this field is expansion portnetwork Number of Port Enter the number of PNs in the cabinet Valid entries Networks are 1 default and 2 Survivable Remote Displays only if the Cabinet Type field is EPN expansion portnetwork If set to y the cabinet has a remote si processor that provides a backup if the links to this cabinet are inoperative 110 Cabinet Field Descriptions Field Name Field Description SurvivableRemote Displays only if the Survivable Remote EPN field is y Processor ID Enter the product ID assigned to the remote si This allows DEFINITY Fault Management to know which machine is the backup for this cabinet The entry in this field cannot be the same as the entry in the Production Identification field in the Maintenance Related System Parameters form Room Enter up to ten characters identifying the room where the cabinet is located Default is blank Floor Enter up to ten characters identifying the floor in the building where the cabinet is located Default is blank Building Enter up to ten characters identifying the building where the cabinet is located Default is blank Carrier Descriptions Carrier Type Enter the type of ca
430. ve Default is upper case Dial Type Adjustable Make Break Ratio This field controls the type of interregister signaling to be used between the modem and the Central Office The field has a default of T for tone dialing Pulse dialing is indicated by P The field length should be 3 characters long This field is concatenated with the dial string This field is not case sensitive Default is upper case This field controls the make break ratios of pulses and DTMF dialing The Intel product information has support for different make break options for pulse dialing only Intel uses amp PO to select a ratio of 39 make and 61 break for communication within the United States and Canada The option amp P1 sets a ratio of 33 make and 67 break for the United Kingdom and Hong Kong This field has a blank default and a 5 character long entry This field is not case sensitive Default is upper case Dial Command This field has a default of in a field 3 characters long This field denotes the dialing command of the modem This is a standard command This field is not case sensitive Default is upper case No Answer Time Out Most external modems provide a timer that abandons any outbound data call after a predetermined interval Some modems disable this timer allowing an outbound call to ring indefinitely Paradyne does not provide this capability because it is undesirable to have an outbound call attempt to
431. ve incoming trunk lines to either loop start or ground start Two switches are used for each circuit switches 1 and 2 are used for circuit 1 switches 3 and 4 are used for circuit 2 and so forth See Trunk Test Switches 3 For loop start set the switches to the left For ground start set the switches to the right 4 Connect a 25 pair cable between the male RJ21 25 pair connector on the Emergency Transfer Panel and the yellow field of the Main Distribution Frame MDF Pin Assignments for 25 Pair Connector shows the pinouts 170 5 Make cross connections for each emergency trunk emergency station pair The 808A is connected to the Main Distribution Frame MDF by means of a B25A cable Connections for Telephone Used for Emergency Transfer shows the connections at the trunk auxiliary field for a telephone used only for emergency transfer Connections for Telephone Used for Emergency Transfer and as Normal Extension shows the connections at the trunk auxiliary field for a telephone used for emergency transfer as well as a normal extension 6 On the trunk identification label at the bottom of the panel record the trunk line extension and location for each circuit 7 To each voice terminal designated as an emergency terminal attach a label identifying it as such The labels are provided with the unit 8 Check the system for normal operation as follows Place the test switch switch 12 in NORMAL OPERATION Ensure the pow
432. verter Facilities heading for each DS1 facility Note The D4 format is supported by the Converter circuit packs but because of problems inherent with this format specifically inability to frame on a bit stream that contains data that emulates the D4 framing pattern its use is discouraged e DS1CONV 1 Line Compensation Enter the line compensation 1 to 5 in the A B C and D columns under the DS1 Converter Facilities heading for each DS1 facility connected to ENDPOINT 1 see Distance to DSX 1 Interface feet The 051 line signal is pre equalized at the transmitter so that DS1 line pulses are the correct amplitude and shape when they reach the Network Interface The amount of equalization necessary is determined by the distance to the Network Interface when the endpoint supplies a DSX 1 interface and also by the type of wiring used to connect to the Network Interface The types of wiring allowed are 22 gauge ABAM shielded twisted pair cable 24 gauge Premises Distribution System PDS wiring and 26 gauge PDS wiring Note The line equalization setting defaults to 2 and remains in effect until changed by administration Because incorrect equalizer settings cause a potentially 408 higher error rate on the DS1 facility it is necessary to provide the correct settings based on the distance to the Network interface If it is a TN574 circuit pack the default for all facilities is 1 e DS1CONV 2 Line Compensation Enter
433. w a level horizontal line on the wall 23 in 58 4 cm above the floor See 110P Type Terminal Blocks 900 Pair To mount the first trunk auxiliary field terminal block partially install 2 3 4 in 12 wood screws 7 11 16 in 19 5 cm apart on the left side of the horizontal line on the wall Slide the bottom terminal block ft onto the mounting screws and mark the upper mounting screw locations Remove the terminal block and partially install the upper mounting screws Place the terminal block on the mounting screws and tighten the screws If installing a vertical patch cord trough partially install the first screw for the patch cord trough on the line 7 8 in 2 2 cm to the right of the previous screw Partially install the second mounting screw 5 31 in 13 5 cm to the right of the screw just installed Repeat Steps 4 5 and 6 If another trunk auxiliary field terminal block is to be installed partially install the first screw for the terminal block on the line 7 8 in 2 2 cm to the right of the previous screw Partially install the second mounting screw 7 11 16 in 19 5 cm to the right of the screw just installed Repeat Steps 4 5 and 6 If a horizontal patch cord trough is to be installed install it on the line between the trunk auxiliary field and the distribution field To install the first distribution field terminal block partially install 2 3 4 in 12 wood screws 7 11 16 in 19 5 cm apart on the line to th
434. wer for Basic Rate Interface BRI and certain display sets The Port Assignment Record must have this information e Station or trunk type or feature service e Building location floor room desk outlet e Extension number or trunk group and member number Port circuit location on the system for each endpoint cabinet carrier slot circuit Route from equipment room through equipment closets to each endpoint Auxiliary power supply if required Main Distribution Frame MDF Hardware SYSTIMAX 110 type hardware is used for the Main Distribution Frame MDF 110 type hardware is available in two basic types the 110A and 110P The 110A requires less wall space than the 110P The 110P includes horizontal and vertical cable troughs for managing cross connect cables The system is connected to the MDF with the supplied B25A male to female 25 pair cables The cables are provided in 10 foot 3 m and 15 foot 4 5 m lengths Example MDF Connections SCC1 Single Carrier Cabinet shows a detailed example of Single Carrier Cabinet cables connecting system cabinets and satellite closets to the Main Distribution Frame MDF The figure shows the cross connections for one example station circuit Example MDF Connections MCC1 Multicarrier Cabinet shows the cross connections for common circuit packs Refer to this figure when cross connecting wire pairs to the MDF Example MDF Connections SCC1 Single Carrier Cabinet 50 25 Pair 9
435. xiliary cable located in the trunk auxiliary field Provide auxiliary power for a primary attendant console through this cable so the console remains fully operational during short power outages Note For aconsole to realize the longest possible nominal battery holdover of 10 minutes the console s TN754B or TN413 Digital Line circuit pack should reside in an EPN s duplicated control cabinet An attendant console can also derive auxiliary power from Individual 1151A1 or 1151A2 power supply 258A type adapters Bulk power supplies such as the 1145B A console s maximum distance from its auxiliary power source is 800 feet 244 m for a 302A1 154 Hard Wire Bridging 350 feet 106 8 m for a 301B1 and 302C1 Analog type hard wire bridging is not allowed for four wire only DCP endpoints Hard wire bridging provides no way of combining the digital output of two bridged DCP sets Also a bridged endpoint causes degradation of the DCP signal A CAUTION Bridging or paralleling these endpoints can cause electrical damage to the consoles or cause the circuit pack to remove power from the consoles Dual Wiring of Two Wire and Four Wire Endpoints Do not simultaneously wire a two wire and four wire endpoint to the same equipment location in an MDF The Avaya Media Server or Gateway uses separate circuit packs to interface two and four wire endpoints Install the Attendant Console Begin Return to Task List 1 Install the
436. y Status Active Standby up up up up STATUS Mj Mn Wn 8 35 8 0 0 Command Return to Task List Test Expansion Interface Circuit Packs Begin Return to Task List Check each Expansion Interface El circuit pack in the system 1 Type test board UUCSS where UUCSS is the cabinet carrier and slot for an Expansion Interface El circuit pack in the system and press Enter Note Labels on the port network and carrier and on the strip under the circuit pack contain this information 2 Verify the screen displays test results similar to Sample Test Results for Expansion Interface Board 2A01 This example is for board 2a01 3 If any result is FAIL check the connections for the fiber optic link 4 Repeat Steps 1 and 2 for each Expansion Interface circuit pack Sample Test Results for Expansion Interface Board 2A01 TEST RESULTS Port Maintenance Name Alt Name Test No Result 02 01 EXP INTF 237 PASS 02 01 EXP INTF 238 PASS 02A01 EXP INTF 240 PASS 02A01 EXP INTF 241 PASS 02A01 EXP INTF 244 PASS 02A01 EXP INTF 316 PASS b Error Code Return to Task List 134 Test Time Division Multiplexing Bus for Each Expansion Port Network Begin Return to Task List Check each TDM bus for each Expansion Port Network EPN in the system 1 2 Sample Test Results for TDM Bus Port Network 2 Type test tdm port network 2 and press Enter Verify a test results screen similar to Sampl
437. y be on but will be turned off by other procedures in this chapter Power Up DC Powered System Begin Return to Task List 1 At the DC Battery Cabinet if installed set the circuit breaker to ON 2 Atthe DC Power Cabinet set the circuit breakers on the associated rectifiers ON This starts the system initialization and test Some red LEDs may be on but are turned off by other procedures in this section 3 Atthe rear of each Power Distribution Unit if installed set the circuit breaker to ON Note If the system is high or critical reliability power up the Expansion Port Network EPN first then the Processor Port Network PPN A ways power up the control cabinet ast Return to Task List Verify Messages on Terminal Begin Return to Task List 1 After several minutes verify all tests pass Typical Start up Messages displays the screen of a typical DEFINITY ECS Note If any of the screen messages indicate a test has failed or if the message spe down mode is displayed refer to the Maintenance for Avaya MultiVantage DEFINITY Server manual for the system to clear the trouble or call your Avaya representative 4 About two minutes after REBOOT PERFORMED is displayed verify the screen displays Login Typical Start up Messages 105 INTERNAL REGISTER TEST LOOP DATA TEST DUART TEST ROM CHECKSUM TEST CONTROL STATUS TEST DCACHE TEST ICACHE TEST WRITE BUFFER TEST BTO TEST MEM CONFIG TEST M
438. ya Media Gateway Through a Modem Task List Make Data Module Settings 1 Set the Data Module to DCE Mode if necessary 2 Add a Data Module to the Switch 3 Test Data Module Hardware Connections 4 Set the Data Module Operating Mode 5 Set the 7400B Data Module Options Install and Use Avaya Site Administration Begin Return to Task List To install Avaya Site Administration your PC or laptop must meet the minimum requirements described in Minimum requirements to run Avaya Site Administration To install Avaya Site Administration on your computer place the Avaya Site Administration CD in the CD ROM drive and follow the installation instructions To start Avaya Site Administration click on Start gt Programs gt Avaya Site Administration Avaya Site Administration supports SAT emulation which is directly equivalent to using the SAT Avaya Site Administration also supports a whole range of other features including the graphically enhanced DEFINITY interface GEDI and Data Import For more information refer to the Help Guided Tour and Show Me accessed from the Help menu Minimum requirements to run Avaya Site Administration Operating systems Processor RAM MS Windows 95 486SL 66 16 MB MS Windows 98 Pentium 32 MB MS Windows NT 4 0 Pentium 64 MB MS Windows 2000 Pentium class 300 MHz 64 MB Graphics adapter SVGA with minimum screen resolution of 800 x 600 Floppy disk drive 3 1 2 in 1 44 MB floppy disk drive CD ROM
439. ya com support If you are Within the United States click Escalation Lists which includes escalation phone numbers within the USA Outside the United States click Escalation Lists then click Global Escalation List which includes phone numbers for the regional Centers of Excellence Providing Telecommunications Security Telecommunications security of voice data and or video communications is the prevention of any type of intrusion to that is either unauthorized or malicious access to or use of your company s telecommunications equipment by some party Your company s telecommunications equipment includes both this Avaya product and any other voice data video equipment that could be accessed via this Avaya product that is networked equipment An outside party is anyone who is not a corporate employee agent subcontractor or is not working on your company s behalf Whereas a malicious party is anyone including someone who may be otherwise authorized who accesses your telecommunications equipment with either malicious or mischievous intent Such intrusions may be either to through synchronous time multiplexed and or circuit based or asynchronous character message or packet based equipment or interfaces for reasons of Utilization of capabilities special to the accessed equipment Theft such as of intellectual property financial assets or toll facility access Eavesdropping privacy inv
440. ystem on page 352 to manually remove the firmware image and disable the file system on the source circuit pack Reseat VAL circuit pack For TN2501AP VAL circuit packs only reseat the TN2501AP to reset the board after the download is complete A caution If you do not reseat the TN2501AP then the pack runs using old firmware WARNING To prevent electrostatic discharge ESD be sure to wear a grounding strap while handling the circuit pack 351 Disable file system A CAUTION Ensure that the top green and top amber LEDs on the TN2501AP are out 1 Release the latch handle to free the TN2501AP from the carrier 2 Pull the circuit pack out about 1 2 inches 3 5 cm 3 Re insert the circuit pack into the media gateway or carrier 4 Close the latch securely 5 Wait until all three of the top LEDs red green and amber are out Note Performing the following steps on the TN799DP C LAN or TN2501AP VAL circuit packs removes only the fiplogin and the ftopassword The allocated memory for the file system remains reserved for the session To free up resources on the source circuit pack you must delete the new firmware image files and disable the file system 1 Type remove file board UUCSS filename ext and press Enter to remove the image file from the source board 2 Type list directory board UUCSS and press Enter 3 Checkthe File Directory Name field to verify that the new firmware image file is not list

Download Pdf Manuals

image

Related Search

Related Contents

  Catalogue E-Cigarettes - E-Vaporisateurs  Manuale Utente User Manual ELFIN FC ELFIN VW  Serie Ekoflux S - Brandoni Valvole Spa  Instruction Booklet  Op Man for WLAN Adapter_DE - Rex-Rotary Vertriebsgesellschaft    Conceptronic Travel Multi Card Reader USB 3.0  Connect Me 3G and Wi-Fi Connection Manager User Guide  

Copyright © All rights reserved.
Failed to retrieve file