1. a supporting wall or panel is a rectangle 4 00 x 8 58 inches 10 20 x 21 79 cm 43 o F center to center 22 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 1 08 2 81 E Fig 3 3 1b lt gt J gt Panel Wall Mounting position 2 The unit is mounted using the brackets as shown in the illustration above The A spacing for the mounting screws into the E supporting wall or panel is a rectangle E 2 81 x 8 58 inches 7 14 x 21 79 cm center to center 8 58 J i LL Sl l 0 304 E Ki 4 00 28 ne eee eae a a ig4 Ld 220 d S o E o Magn m 6KL Fig 3 3 1 Typical Panel Wall mounting of the 6KL Switch position 2 shown www GarrettCom com 23 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 3 4 Powering the Magnum 6KL Managed Edge Switch The DC internal power supply supports installation environments where the DC voltage is from 10 to 300 volts depending on the model selected The power consumption will range from about 10 up to 15 watts depending on the port quantity and types in the configuration When connecting the Ethernet cabling there is no need to power d
2. IE Bezza nan fot is 4 The 6KL4 2SL2MLC 4 port Fiber module provides two 100Mb Singlemode LC Fiber ports and two 100Mb Multimode LC Fiber ports The 6KL4 1SL3MLC 4 port Fiber module provides one 100Mb Singlemode LC Fiber port and three 100Mb Multimode LC Fiber ports Both modules above are Small Form Factor SFF LC connectors in ALe2222 Singlemode and Multimode fiber configurations The Singlemode connectors supporting distances up to 20Km and Multimode connectors supporting up to 2Km distances 5 1 14 6KL4 1IMLISLC2RJ Slot C 1 x LC Multimode 1 x LC Singlemode 2 x RJ45 S e Joe in Fama Se ae The 6KL4 1ML1SLC2RJ 4 port Fiber Copper module provides one 100Mb Multimode LC Fiber port one Singlemode LC Fiber port and two 10 100Mb switched RJ 45 ports The Singlemode connectors support distances up to 20Km and Multimode connectors supporting up to 2Km distances The 6KL4 1ML1SLC2RJ copper ports support Ethernet twisted pair segments of any
3. 5 1 18 6KL1 1MLC 1SLC 1SLCL 1 x LC Slot C The 6KL1 1MLC 1 port Fiber module provides one 100Mb Multimode LC Fiber port Supports fiber optic cable distances up to 2Km The 6KL1 1SLC 1 port Fiber module provides one 100Mb Singlemode LC Fiber port Supports fiber optic cable distances up to 20Km The 6KL1 1SLCL 1 port Fiber module provides one 100Mb Singlemode LC Fiber port Supports fiber optic cable distances up to 40Km see 5 1 3 for more details 5 1 19 6KL1 1MT 1 x MTRJ Multimode Slot C The 6KL1 1MT 1 port Fiber module provides one 100Mb Multimode MTRJ Fiber port Supports fiber optic cable distances up to 2Km see 5 1 7 for more details 39 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 5 1 20 P6KL4 RJ45 4 x PoE RJ45 Slot C SAARA oo int I Tm fa a The 6KL is available with the option of having PoE capabilities on the four RJ45 ports in slot C This is used in conjunction with 6KLP 48VDC to add an additional four PoE ports to the existing four PoE ports in slot A Bloogo The PoE Power over Et
4. 6KL Managed Edge Switch Installation and User Guide 05 12 ST Fiber ports and two 10Mb Multimode ST Fiber ports This option utilizes a ST type twist lock fiber optic connection Port 1 is marked TX transmit and RX receive for clarity All other fiber ports follow this same configuration Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being received 5 1 10 6KL4 4SSC 6KL4 4SSCL Slot C 4x SC Singlemode The 6KL4 4SSC 4 port Fiber module provides four 100Mb Singlemode SC Fiber ports supporting distances up to 20km This module provides the same functions as the Multimode version see Section 5 1 9 for more details The 6KL4 4SSCL 4 port Fiber module provides four 100Mb Singlemode SC Long Reach Fiber ports supporting distances up to 40km This module provides the same functions as the Multimode version see Section 5 1 9 for more details 5 1 11 6KL4 2MSC2RJ 6KL4 2MST2RJ Slot C 2 x SC Multimode or 2 x ST Multimode 2 x RJ45 4 HEE r el ol TO TOT Fama T o m I found fu Pa J The 6KL4 2MSC2RJ shown 4 port Fiber Copper module provides two 100Mb Multimode SC Fiber ports and two 10 100Mb switched RJ45 ports This option utilizes a SC type push pull fiber optic connection The 6KL4 2MST2RJ 4 por
5. CHASSIS connection terminals so that the GND GND power from an external source can only flow into the hub This allows the Switch to operate only whenever DC power is 46 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 correctly applied to the two inputs It protects the Switch from incorrect DC input connections An incorrect polarity connection for example will neither affect the Switch its internal power supply nor will it blow the fuse in the internal power supply B3 0 APPLICATIONS FOR DC POWERED ETHERNET SWITCHES Magnum 6KL Switches are easily installed in a variety of applications where 12 24 48VDC 125 and 250VDC power is used as the primary power source The DC power configuration capability provides an Ethernet networking solution utilizing a special power supply in switches with a proven track record The 48 VDC solution is particularly useful in the telecommunication industry where it is common for facilities to operate on 48VDC power Such companies include regular and wireless telephone service providers Internet Service Providers ISPs and other communication companies In addition many high availability equipment services such as broadcasters publishers newspaper operations brokerage firms and other facilities often use a battery backup system to maintain operations in the event of a power failure It is also frequently used for computer system backup management and operations monitoring
6. ZX full duplex single mode 9um cable gt 70km Fiber Multi mode connector types supported Fiber Port MTRJ type plug in SFF Fiber multi mode 100BASE FX Fiber Port LC type plug in SFF Fiber multi mode 1OOBASE FX Fiber Port SC type plug in multi mode 100BASE FX Fiber Port ST type twist lock multi mode 100BASE FX Fiber Port 1OOOBASE SX SFP modules Fiber Single mode connector types Fiber Port LC type Fiber SFF single mode 100BASE FX Fiber Port SC type single mode 1OOBASE FX Fiber Port OOOBASE LX SFP modules LEDs Per Port one set at the port see section 5 1 1 for detailed LED configurations Operating Environment Ambient Temperature 40 to 140 F 40 to 60 C for UL60950 and Component Parts rating 40 to 195 F 40 to 85 C for IEC 60068 Type Test short term rating Storage Temperature 60 to 210 F 50 to 100 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating humidity protection optional Request quote Alarm Relay Contacts One NC indicating internal power one NC software controllable Packaging Enclosure High strength Cold rolled steel Dimensions 8 0 in H x 1 75 in W x 6 0 in D in vertical mounting position 20 3 cm H x 4 4 cm W x 15 2 cm D Cooling method Convection fully enclosed steel case used as a heat sink designed for vertical mounting no fans Weight 2 1 lbs 0 95 kg DC Power Supply Internal f
7. as 6KL 24VDC except the power input is 250VDC Magnum 6KL AC Same as 6KL 24VDC except the power input is AC 100 to 240VAC 47 to 63 Hz Please use this URL for the complete Configuration Guide for the Magnum 6KL http www garrettcom com techsupport insertion_guides 6KLcg pdf Configuration Options see following pages Each Magnum 6KL base unit may be configured with a choice of 1 modular slot Slot C and fixed Gigabit ports Slot B in addition to the fixed RJ45 ports in Slot A Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 Following modules can be configured in Slot C only Magnum 6KL Slot C Port Modules 6KL4 RJ45 adds four 10 100 copper ports P6KL4 RJ45 adds four PoE 10 100 copper ports requires 6KLP 48VDC base unit PP6KL4 RJ45 adds four PoE 10 100 copper ports 6KL4 4MLC adds four MM 2Km 100Mb LC fiber ports 6KL4 2MLC2RJ adds two MM 2Km 100Mb LC fiber and two 10 100 copper ports 6KL4 4SLC adds four SM 20Km 100Mb LC fiber ports 6KL4 2SLC2RJ adds two SM 20Km 100Mb LC fiber and two 10 100 copper ports 6KL4 4SLCL adds four SM 40Km 100Mb LC fiber ports 6KL4 2SLCL2RJ adds two SM 40Km 100Mb LC fiber and two 10 100 copper ports 6KL4 4MTRJ adds four MM 2Km 100Mb MTRJ fiber ports 6KL4 2MT2RJ adds two MM 2Km 100Mb MTRJ fiber and two 10 100 copper ports 6KL4 4MSC adds four MM 2Km 100Mb SC fiber ports 6KL4 2MSC2RJ adds two MM 2Km 100Mb SC fiber and two 10 100 copper ports 6KL4 4SSC adds four SM 20Km 100Mb SC fibe
8. auto negotiation is not disabled The F H LED is ON to indicate full duplex operation and OFF to indicate the half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be ON indicating there is a powered up device at the other end of the cable in order for a LK LED to provide valid indications of operating conditions on that port Using the 6K MNS 6K or MNS 6K SECURE management software the user may disable auto negotiation and fix the desired operation of each RJ 45 port The user may select 1OMb or 100Mb speed and full or half duplex mode per port as per user requirements See Magnum MNS 6K Software Manual for additional info NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6KL It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce high greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6KL passes the 1613specifications for zero packet loss with fiber ports and with RJ 45 ports used as indicated here 33 Magnum 6KL Managed Edge Switch I
9. including hardened enclosures a wide spread of DC power supply options and extended temperature ratings qualifies the Magnum 6KL Managed switch for any Industrial factory floor traffic control transportation system or power utility application The several MNS 6K software operated features qualifies this managed switch to operate and perform securely and reliably in all critical applications The addition of S Ring and the Link Loss Learn software features allow this Managed switch to provide a very secure highly available redundant network capability in any ring topology network The Managed 6KL s modularity along with the MNS 6K management software features remarkably handle industrial environments i e where the factory floors are networked with Ethernet based mixed media LANs equipped with PLCs computers for taking readings and data from Machines Client Server databases etc and sending these important data to the central office data warehouses very securely and reliably The DIN Rail Mounting options on the Magnum 6KL allow the factory floor s industrial user to mount the 6KL securely anywhere on their Network setup The option of setting the ports at 10 or 1OOMb on copper and 100Mb on fiber media provide widespread options to the users to mix and match their legacy and advance network needs The modularity of the 6KL Managed Edge Switches make them an attractive choice for use in applications with LAN connections to an organization
10. monitoring and securing the premises ww GarrettCom com 16 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 3 0 INSTALLATION Before installing the equipment it is necessary to take the following precautions 1 If the equipment is mounted in an enclosed or multiple rack assembly the steady state long term environmental temperature around the equipment must be less than or equal to 60 C 2 If the equipment is mounted in an enclosed or multiple rack assembly adequate airflow must be maintained for proper and safe operation 3 If the equipment is mounted in an enclosed or multiple rack system placement of the equipment must not overload or load unevenly the rack system 4 If the equipment is mounted in an enclosed or multiple rack assembly verify the equipment s power requirements to prevent overloading of the building s electrical circuits 5 If the equipment is mounted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This section describes installation of the Magnum 6KL Switches as well as connection of the various Ethernet media types 3 1 Locating Magnum 6KL Switches For vertical DIN Rail mounting see Section 3 3 For vertical panel mounting and wall mounting see Section 3 3 1 For DC power input data see Appendix B For Dual Source see Appendix C The rugged metal case of the Magnum 6KL will normally protect it f
11. standard length It is equipped with a two port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections When installed in a Magnum 6KL Series Managed Switch the copper ports support the standard distance of 100m on each port www GarrettCom com ss 38 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 5 1 15 6KL4 1IMLC3RJ 1 x LC Multimode 3 x RJ45 Slot C The 6KL4 1MLC3RJ 4 port Fiber Copper module provides one 100Mb Multimode LC Fiber port supporting distances up to 2km and three 10 100Mb switched RJ45 ports see 5 1 2 and 5 1 3 for more details 5 1 16 6KL4 1SLC3RJ 6KL4 1SLCL3RJ Slot C 1 x LC Singlemode 3 x RJ45 The 6KL4 1SLC3RJ 4 port Fiber Copper module provides one 100Mb Singlemode LC Fiber port supporting distances up to 20km and three 10 100Mb switched RJ45 ports The 6KL4 1SLCL3RJ 4 port Fiber Copper module provides one 100Mb Singlemode LC Fiber port supporting distances up to 40km and three 10 100Mb switched RJ45 ports see 5 1 2 and 5 1 3 for more details 5 1 17 6KL4 1MT3RJ 1 x MTRJ Multimode 3 x RJ45 Slot C The 6KL4 1MT3RJ 4 port Fiber Copper module provides one 100Mb Multimode MTRJ Fiber port supporting distances up to 2km and three 10 100Mb switched RJ45 ports see 5 1 2 and 5 1 7 for more details
12. the copper ports support the standard distance of 100m on each port see Sections 5 1 2 and 5 1 3 for more details 5 1 6 6KL4 2SLC2RJ 6KL4 2SLCL2RJ Slot C 2 x Singlemode LC 2 x RJ45 The 6KL4 2SLC2RJ 4 port Fiber module provides two 100Mb Singlemode LC Fiber ports supporting distances up to 20km and two 10 100Mb switched RJ45 ports This module provides the same functions as the Multimode version see Section 5 1 2 and 5 1 3 for more details The 6KL4 2SLCL2RJ 4 port Fiber module provides two 100Mb Singlemode LC Fiber ports supporting distances up to 40km and two 10 100Mb switched RJ45 ports This module provides the same functions as the Multimode version see Section 5 1 2 and 5 1 3 for more details 5 1 7 6KL4 4MTRJ 4 x Multimode MTRJ Slot C caza m a a M MUDD Ml The 6KL4 4MTRJ 4 port Fiber module provides four 100Mb Multimode MTRJ Fiber ports The 6KL4 4MTRJ fiber port is a Small Form Factor SFF MTRJ Multimode connector The MTRJ s small size and ease of connection make it a good choice for ooo Bloogo 100Mbps fiber to the desktop Ethernet connectivity When installed in a Magnum 6KL Series Switch it supports fiber optic cable distances up to the IEEE standard 100Mbps distance limi
13. topology of the network consists of high speed LAN segments supported by 100Mbps full duplex future proof fiber media to provide a secure long distance LAN connection The entire network is sharing a higher bandwidth Gigabit enabled data mining server for the vital database located in a separate secured building The copper ports are required for multiple subnets inside the power plant to check the status of other Ethernet units The entire spread network will be manageable to provide easy detectable uninterrupted support through a viewable SNMP monitor Magnum 6K32 Factory Floor PLC Factory Floor PLC Factory Floor PLC Fig 2 5b Magnum 6KL equipped with S Ring in redundant ring solution The Magnum 6KL Managed Edge Switch equipped with a mix of copper and fiber ports provides an economical and seamless solution to many requirements The user configurable Magnum 6KL provides an extra boost to the network requirements by www GarrettCom com 15 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 providing copper fiber media along with the higher bandwidth support of 10 100 and 1000Mb The user can utilize the SNMP feature equipped with VLAN RMON STP and other standard managed LAN features to provide a secure and stable network The 6KL Managed Fiber with S ring and Link Loss Learn features easily fulfill the redundant requirement with a secure and fast reconfiguration time for cable breakup when set up in a
14. you need to ship the unit back to GarrettCom please follow these instructions 1 Package the unit carefully It is recommended that you use the original container if available Units should be wrapped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for your return shipping charges Ship the package to GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom During this warranty period GarrettCom will repair or at its option replace components in the products that prove to be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by misuse misapplication or as a result of service or modification other than by GarrettCom GarrettCom reserves the right to make a charge for handling and inspecting
15. 438 9072 Website http www GarrettCom com Email support garrettcom com www GarrettCom com i Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not installed and used properly in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at their own expense will be required to take whatever measures may be required to correct the interference Canadian Emissions Statement This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil respecte toutes les exigences du R glement sur le mat riel du Canada Cet appareil est Classe A Electrical Safety requirements 1 This product is to be installed Only in Restricted Access Areas Dedicated Equipment Rooms Electrical Closets or the like 2 48VDC products shall be installed with a readily accessible disconnect device in the build
16. BASE X Ethernet IEEE 802 1p Priority protocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking IEEE 802 1x Port based Network access control IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet PoE Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 10BASE FL multi mode fiber optic 2km 6 562 ft 10BASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast Ethernet Segment Lengths 10BASE T CAT 3 4 5 UTP 100 m 328 ft 100BASE TX CAT 5 UTP 100 m 328 ft Shielded twisted pair 150 m 492 ft 100BASE FX half duplex multi mode 412 m 1350 ft 100BASE FX full duplex multi mode 2 0 km 6 562 ft 100BASE FX half duplex single mode 412 m 1350 ft 100BASE FX full duplex single mode 20 0 km 66K ft 100BASE FX full duplex Long Reach 40 0 km 122K ft Maximum Standard Gigabit Ethernet Segment Lengths 1000BASE T CAT5e or higher is recommended 100m 328 ft 1000BASE SX full duplex multi mode 62 5um cable 220m ww GarrettCom com 1 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 1000BASE SX full duplex multi mode 501m cable 550m 1000BASE LX full duplex multi mode 50 62 5um cable 550m 1000BASE LX full duplex single mode 9um cable 5km 1000BASE
17. Edge Switch Installation and User Guide 05 12 6 0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of a Magnum 6KL Switch is a straight forward procedure The operation is also straightforward and is discussed in Section 4 0 of this 6KL User Guide Should problems develop during installation or operation this section is intended to help locate identify and correct these types of problems Please follow the suggestions listed below prior to contacting your supplier However if you are unsure of the procedures described in this section or if the Magnum 6KL Switch is not performing as expected do not attempt to repair the unit instead contact your supplier for assistance or contact GarrettCom Customer Support 6 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can be attributed to wiring and connector problems 3 Make sure that power is properly attached to each Magnum 6KL Switch unit Use the PWR LEDs to verify eac
18. KL Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to the devices sending it packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows the traffic to catch up without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a small fraction of a second and is transparent to an observer Another feature implemented in the Magnum 6KL Switches is a collision based flow control mechanism when operating at half duplex only When the Switch detects that its free buffer queue space is low the Switch prevents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic 10 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 2 3 Managed Network Software for Magnum 6KL Magnum 6KL comes with licensed MNS 6K software or MNS 6K SECURE which allow the user to configure the Magnum 6KL as a Managed Switch and implements security features and other software enabled features NOTE Magnum 6KL managed switch will work with MNS 6K Rel v4 1 6 firmware or higher version only or MNS 6K SECURE v14 1 6 firmware or higher version only Using any earlier MNS 6K versions will not support the 6KL hardware For PoE PP6KL4 RJ45 supported software release visit Garrettcom s web site at http Aww
19. Substations Jn support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ45 console ports are intended for temporary connectivity to other equipment such as PCs Since the console port connection is temporary it is excluded from IEEE 1613 packet loss testing per the 1613 standard defined test procedure 4 0 OPERATION This chapter describes the functions and operation of the Magnum 6KL Switch 4 1 Switching Functionality A Magnum 6KL provides switched connectivity at Ethernet wire speed among all of its ports The Magnum 6KL supports10 100Mbs for copper media and 100Mb separate traffic domains for fiber ports to maximize bandwidth utilization and network performance All ports can communicate to all other ports in a Magnum 6KL but local traffic on a port will not consume any of the bandwidth on any other port The Magnum 6KL units are plug and play devices There is no software configuring necessary to be done for basic operation at installation or for maintenance There is an optional Half Full duplex mode and 10Mbps or 100Mbps selection for the switched ports which must be configured through MNS software per unit as per the requirement The internal functions of both are described below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addre
20. The LEDs on the PoE ports are slightly different compared to regular non PoE RJ45 ports When the PoE port is in use the POE LED is ON when connected properly to an IEEE 803 af or 802 3at compliant PD device on that port When non PoE devices are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as L A 40 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 PoE LEDs Summary e For PoE devices each RJ45 PoE port supports 802 3af or 802 3af 802 3at with PoE plus module installed complaint devices The PoE LED is ON when the attached PD is drawing power from the port The power is supplied on the data pairs per IEEE802 3af or 802 3at PoE standard e For non PoE devices connected the PoE port will act as a normal RJ45 port and the PoE LED is OFF No power is sent out from the port e The PoE ports in Magnum 6K s with 48VDC power input act as a pass through so the 48VDC power input source to the Magnum 6KL must be strong enough to provide power to the 6K switch and to all 4 RJ45 ports with PD devices connected up to 15 watts per PoE port for IEEE802 3af or 25 watts per IEEE802 3at In the case where the 48VDC power in not internally connected to the POE port pins and no power is coming to the PoE ports for some reason all the PoE port LEDs are ON simultaneously to indicate a trouble condition The por
21. Troubleshooting for specific return procedures Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 2 2 Product Description Magnum 6KL Managed Edge Switch Magnum 6KL Managed Edge Switches provide configurability in an entry level industrial grade package The high performance 6KL base unit comes with four 10 100 copper ports which may be either regular or PoE Up to 4 100Mb fiber ports or up to four more 10 100 copper ports or combinations may also be configured In addition one or two Gb ports may be configured as 10 100 1000 copper or SFP fiber in any 6KL base unit Magnum 6KL comes with the best of breed MNS 6K managed networks software MNS 6K SECURE optional See the Managed Networks Software MNS 6K datasheet for more information at http www garrettcom com techsupport software datasheets mns6kds pdf Magnum 6KLs are ideal for building a switched hardened Ethernet network infrastructure connecting edge devices such as PLCs and IEDs with upstream switches or routers Designed for use in industrial applications such as factory floors and control cabinets industrial video surveillance systems with PoE power utility substations tariffed carrier field facilities or transportation and oil and gas the rugged Magnum 6KL handles stressful workloads mixes of bursty data traffic and priority streaming traffic as well as harsh environmental conditions The 6KL metal case serves as a heat sink and a sealed case de
22. agnum 6KL Managed Edge Switch Installation and User Guide 05 12 5 1 2 6KL4 RJ45 4 x 10 100Mb RJ45 Slot C Eet BE Pot ae et Z2eSo2 m so The 6KL4 RJ45 4 port Copper module provides four 10 100Mb switched RJ 45 ports The 10 100Mb switched ports normally as a default setting are independently N way auto negotiating and auto crossover MDIX for operation at 10 or 1OOMb speed al ral at le Beoeo in full or half duplex mode i e each independently selects a mode and speed to match the device at the other end of the twisted pair cable for auto negotiation and MDIX details see Section 4 2 in the 6KL User Guide On the model 6KL4 RJ45 module there are three LEDs for each port two integrated into the connector and one below the connector The LK ACT LED indicates LK Link ready for operation on that port when lit The ACT Activity LED indicates receiving Activity on that port when blinking The 10 100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF when
23. agnum switches and routers as well as other vendor s industry standard RSTP products Redundant topologies may include rings dual rings and complex meshes 8 S 8 Magnum GKL 2 5 Applications Magnum 6KL Edge Switches offer high performance modularity and availability They provide the flexibility of 100Mbps fiber and copper ports as well as single or dual Gigabit 1000Mb ports with industry standard LAN management software Magnum 6KL Switches are easily used in a variety of applications including client server computing secure VLAN performance upgrades to departmental networks and stream traffic for VOIP and audio video applications They can also be used in a much diversified combination of mixed media in Industrial floor applications The performance characteristics of the 6KL Switches enable them to inter connect a series of subnets one subnet per 6KL Switch port in a LAN traffic center The subnet connections may be via fiber or twisted pair cabling 100Mbps or 10 Mbps speed and full or half duplex The mixed media modular capability is ideal for industrial applications where existing Ethernet LAN network cabling must be accommodated The fiber built in media capability is ideal for integrating future proof fiber cabling into the LAN structure 13 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 Example 1 Magnum 6KL Switch for an Industrial Application Equipped with lots of useful features
24. and User Guide 05 12 5 1 11 6KL4 2MSC2RJ 6KL4 2MST2RJ Slot C ce ceeeseerteeeeee 37 5 1 12 6KL4 2SSC2RJ Slot C oo ce eeceecccecceecceeceseceeeceeeseeeseeeeeneeees 38 5 1 13 6KL4 2SL2MLC 6KL4 1SL3MLC Slot C ce eeereereee 38 5 1 14 6KL4 IMLISLC2RJ Slot C cece ee eceeeseceteceeecneeeeeneeeeeees 38 5 1 15 6KL4 IMLC3RJ 1 x LC Multimode 3 x RJ45 Slot C 39 5 1 16 6KL4 1SLC3RJ 6KL4 1SLCL3RJ Slot C eee ceeeeeereees 39 5 1 17 6KL4 IMT3RJ 1 x MTRJ Multimode 3 x RJ45 Slot C 39 5 1 18 6KLI1 IMLC 1SLC 1SLCL 1 x LC Slot C 0 ee 39 5 1 19 6KLI IMT 1 x MTRJ Multimode Slot C eee eeeeeereees 39 5 1 20 P6KL4 RJ45 4 x PoE RJ45 Slot C 0 ee ceeceseeeseeeeeeseeeeeeereees 40 5 1 21 PP6KL4 RJ45 4 x PoE Plus RJ45 Slot C eeeeeeeceereee 40 5 1 22 6KL 2GCU 2 x Gigabit RJ45 Slot B ee eeeceseeseereeeeeees 42 5 1 23 6KL 2GSFP 2 x Gigabit SFP Slot B 0 cece eeseeeseesseseeeeeees 42 6 0 TROUBLESHOOTING seesessessossesocesesccsossessossesoossesoesossossosseesossesoesse 43 6 1 Before Calling for Assistance ceceeseseesceseceeeseceeeeceeeeeeeeneeeees 43 6 2 When Calling for Assistance 0 cee eeeeecseeeceseeeeseeseeeeeseeaeeseeneeeees 43 6 3 Return Material Authorization RMA Procedure ccccceeee 44 6 4 Shipping and Packaging Information cee eeeeceseeeeeseceeeeeeeeeee 45 APPENDIX A WARRANTY INFORMATION ccccssccssscssscs
25. any product returned for warranty repair which turns out not to be faulty 45 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 APPENDIX B DC Power Input B1 0 Specifications for Magnum 6KL Switches DC Power at 12 24 48 125 and 250VDC Power input Each Magnum Model 6KL Managed Switch requires DC power input at 12 24 48 125 and 250VDC nominal The wide range of DC power input types qualifies this product for use in 12 24 48 125 and 250VDC applications in different industries DC Power Terminals are internally floating so that user may ground either GND ground wire connection to the 6KL chassis 6 32 thread Fig B1 0a Location of chassis ground Power Consumption 15 watts typical for a fully loaded fiber model with 2Gb 10 watts typical for 8 ports copper and 100Mb fiber 12VDC Power Input nominal range 10 to 15 VDC 24VDC Power Input nominal range 18 to 36VDC 48VDC Power Input nominal range 36 to 60VDC 125VDC Power Input nominal range 88 to 150VDC 250VDC Power Input nominal range 160 to 300VDC Standard 6KL DC Power Input Terminal Block GND See also Section 1 0 Technical Specifications for the 6KL base unit B2 0 12 24 48 125 and 250VDC POWER THEORY OF OPERATION The 12 24 48VDC POWER SWITCH SWITCH 125 and 250VDC power options SUPPLY are designed using diodes inside At T on each DC power input line A behind the two external power P
26. ctor is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established 3 2 3 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the core plus the cladding respectively Single mode fiber allows full bandwidth at longer distances about 70km with the single mode LC 19 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 3 2 4 Gigabit SFP Small Form factor Pluggable Transceivers The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications applications Due to its compact hot pluggable characteristics SFPs are becoming a very popular choice for various applications The small chassis Magnum 6KL is designed for industry standard Gb SFPs for user selection of the SFP gigabit media type as desired All SFPs used in Magnum 6KLs are compliant with the industry standard Multi Source Agreement MSA ensuring compatibility with a wide range of networking kit
27. ctory installed add Dual Src xxx V as a separate line item following the product model Example Magnum 6KL 48VDC Dual Sre 48V See the Configuration Guide on the GCI web site at http www garrettcom com techsupport insertion_guides 6KLcg pdf for additional information 51
28. d NC contact is held close during normal software operation A user defined software malfunction such as an SNMP Trap or a Software Security violation or an S Ring Fault causes the contact to open and thus triggers an alarm in the user s monitoring system The second NC Alarm Contact is held closed when there is power on the main board inside of the Switch This provides a Hardware Alarm labeled H W because the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power supply inside of the Magnum Switch Useful info about Alarm contacts 1 There are four terminal blocks 1 2 3 4 provided next to the Console port 2 The left two pins 1 2 are hardware operated 3 The right two pins 3 4 are software operated 4 These are both NC normally closed relays 5 The switch s software operation needs to be enabled and set to get the Alarm traps For detailed information about the Software Alarm and software control of SNMP alarm traps please reference the Magnum MNS 6K Software User Manual The Alarm Contacts are on the front left area next to the Console port of the Magnum 6KL unit and are green in color as shown in the picture Fig 3 5a Alarm Contacts 1 2 are hardware operated 3 4 are software operated 25 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 3 6 Connecting the Console Terminal to Magnum 6KL Use a RJ45 null mod
29. e model Dual Sre 250V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 160 300 VDC With the exception of the dual DC input power connections and the power supply all specifications and configuration options for the Magnum 6KL 48VDC 12VDC 24VDC 125VDC and 250VDC models with this Dual Source option are identical to those listed in the Magnum 6KL Edge Switches Installation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6KL with DC Dual Source option The 6KL Switch models with the internal 48VDC 12VDC 24VDC 125VDC and 250VDC Dual Source power supply are designed for installations where a battery plant is the power source and where two separate power sources are utilized in order to increase operational uptime and to simplify maintenance The functionality of the Magnum 6KL Switch 48VDC 12VDC 24VDC 125VDC and 250VDC Dual Source Option units are identical to the AC powered models Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6KL Switches _www GarettCom con s lt s s s 49 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 C3 0 DUAL SOURCE OPTION THEORY OF OPERATION The Dual Source DC power option is designed using diodes inside of the chassis on each DC power input line A diode is placed in
30. e Switch reduce the buffer space used When the available free buffer queue increases the Switch will send a RESUME packet to tell the transmitter to start sending the packets Of course the transmitting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 6KL Switch implements a back pressure algorithm on 10 100 Mb ports for flow control That is the switch prevents frames from entering the device by forcing a collision indication on the half duplex ports that are receiving This temporary collision delay allows the available buffer space to improve as the switch catches up with the traffic flow 29 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 4 4 Power Budget Calculations for 6KL Modules with Fiber Media Receiver Sensitivity and Transmitter Power are the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power Budget P min Pp min where Pr Transmitter Output Power and Pg Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 and 50 125um M m is 2 8 dB km and the Cable Loss for 100 140 Multi mode is 3 3 dB k
31. e information 3 2 1 Connecting Twisted Pair CAT3 CAT5 UTP or STP The RJ 45 ports of the Magnum 6KL can be connected to the following two media types 1OOBASE TX and 1OBASE T CAT 5 cables should be used when making 100BASE TX connections When the ports are used as 1OBASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft NOTE Jt is recommended that high quality CAT 5 cable be used whenever possible in order to provide flexibility in a mixed speed network since 10 100 copper switched ports are auto sensing for either 10 and 100Mb s The following procedure describes how to connect a 1 OBASE T or 1OOBASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 Using standard twisted pair media insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK LED to ensure proper connectivity by noting that the LED will be illuminated when the unit is powered and proper connection is established _www GarettCom con ss 18 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI adv
32. e potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at the last When power is applied the green PWR LED will illuminate Note The GND should be hooked up first The 6KL unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting live power lines to the Terminal Block of 48VDC 12VDC 24VDC 125VD or 250VDC products always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from 48V or 48V supply must be connected to the post labeled B4 1 UL Requirements for DC powered units CAUTION 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product Minimum 18AWG cable for connection to a Centralized DC power source 1 Minimum 14AWG cable for connection to an earth wiring 2 Use only with Listed 10A circuit breaker provided in building installation 3 Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 4 Fastening torque of the lugs on the terminal block 9 inch pound max 5 To secure a centralized DC Power Source cable use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal bl
33. each of the four input lines behind the four external power A SWITCH SUPPLY connection terminals so that power from an external source can only flow into the unit This B allows the unit to operate B whenever DC power is correctly applied to either or both of the two GND GND inputs C4 0 FEATURES AND BENEFITS OF THE DUAL SOURCE DESIGN a The Switch unit can receive power from either input A or B The hub will normally draw its power from the DC source with the highest voltage at a given time b The Switch unit will not allow power to flow from a higher voltage input to a lower voltage input i e the two DC power sources are not mixed together by the hub c When one correct DC input is present the Switch will receive power if the other DC input is absent or even if it is connected with reverse polarity or shorted or grounded d Reverse polarity connections if they should accidentally occur on either input will not damage the Switch or power supply internally nor will it blow the fuse in the internal power supply because of the blocking action of the diodes This is true even if one input connection is reversed while the Switch is operating from the other source e The Switch will not receive power and will not work when both inputs are simultaneously absent or are both incorrectly connected Figure C5 0a DC Dual Source wiring connections with Dual Source option Dual So
34. em cable to connect the Magnum 6KL Console Port the RJ45 Console port on the 6KL Switch to your PC so that your PC becomes the 6KL Console Terminal Note The RJ45 cable is not included with the 6KL package Note For a detailed description of Managed Network Software MNS 6K and Magnum 6KL Switch configuration for Network Management please refer to Magnum 6K Software Manual available on GarrettCom s FTP site Also available on GCI website at http www garrettcom com techsupport sw_downloads htm 3 6 1 RJ45 Console port Serial port pin assignments Pin 8eliiiii4 Pin 1 RJ45 6KL Console port connector Pin Signal Description 1 RTS Request to Send 2 open not used 3 TXD Transmit Data output 4 GND Ground 5 GND Ground 6 RXD Receive Data input 7 open not used 8 CTS Clear to Send The above provided information enables a managed station a PC or Console terminal to connect directly to the switch Note To use the Console port to configure the managed switch a serial Null modem male to male cable is required to communicate properly The Null Modem RJ45 cable is optional and can be ordered from the factory along with the unit as CONSOLE CBLQD for serial port CONSOLE CBLQU for USB port _ www GarrettCom com s s s s se 26 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 NOTE for Power
35. equipment The 24V and 125VDC options are particularly useful in the industrial environment where it is common for facilities to operate on 24VDC or 125VDC power The 125VDC options are mainly used in power utilities such as electrical substations electrical generating plants etc The 24VDC applications are mainly in heavy duty industrial automation such as factory floor process plants HVAC military equipment etc B4 0 6KL 12 24 48 125 and 250VDC INSTALLATION This section describes the proper connection of the leads to the DC power terminal block on the Magnum 6KL Switch The DC terminal block on the Magnum 6KL Managed Switch is located on the left front of the unit and is equipped with four 4 screw down lead posts The power terminals are identified as positive and negative and they are electrically floating inside the unit so that either may be grounded by the user if desired The chassis is earth or ground GND The connection procedure is straightforward Simply insert the DC leads to the Switch s power terminals positive and negative screws The use of Ground GND connects to the Switch chassis screw provided under the DC terminal Ensure that each lead is securely tightened 47 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 NOTE Always use a voltmeter to measure the voltage of the incoming power supply and figure out the ve potential lead or ve potential lead The more v
36. h unit is receiving power 4 If the problem is isolated to a network device other than the Magnum 6KL Switch product it is recommended that the problem device be replaced with a known good device Verify whether or not the problem is corrected If not go to Step 5 below If the problem is corrected the Magnum 6KL Switch and its associated cables are functioning properly 5 If the problem continues after completing Step 4 above contact your supplier of the Magnum 6KL Switch unit or if unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance 6 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components involved in the problem d Any particular application that when used appears to create the problem 43 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 2 An accurate list of GarrettCom product model s involved with serial number s Include the date s that you purchased the products from your supplier 3 It is useful to include other network equipment models and related hardware including personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration pr
37. hernet RJ45 ports are similar to regular RJ45 ports except they have the capability of providing power on each port to power up attached PD devices per the IEEE802 3af PoE standard The power pass through PoE ports are dependent upon the 48VDC input power to supply the PD power for these RJ45 10 100 ports Each port supplies up to 15watts to power attached PoE PD devices The LEDs on the PoE ports are slightly different compared to regular non PoE RJ45 ports When the PoE port is in use the POE LED is ON when connected properly to an IEEE 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF Operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combined on the PoE modules into one LED that is marked as L A 5 1 21 PP6KL4 RJ45 4 x PoE Plus RJ45 Slot C The 6KL is available with the option of having PoE capabilities on the four RJ45 ports in slot C This can be used with all 48VDC base units to add four PoE ports to the existing four non PoE or PoE ports in slot A The PoE Power over Ethernet RJ45 ports are similar to regular RJ45 ports except they have the capability of providing power on each port to power up attached PD devices per the IEEE802 3at PoE standard The power pass through PoE ports are dependent upon the 48VDC input power to supply the PD power for these RJ45 10 100 ports Each port supplies up to 25watts to power attached PoE PD devices
38. ing Dimensions for 6KL with metal brackets Each Mangum 6KL is supplied with metal mounting brackets and screws to mount the unit securely on a panel or wall It is recommended to mount the 6KL vertically in one of the two mounting positions available as shown below for proper cooling and long life reliability It is also advisable to mount the unit with space for air movement around the top and the sides typically a minimum of 1 inch Note The metal brackets supplied hold the back of the 6KL unit out from the panel or wall behind it creating a rear space of about 1 8 inch or 3mm This allows air circulation and cooling of the rear part of the case For best cooling of the 6KL attach the metal brackets to metal rather than wood or plastic Attaching to metal helps conduct heat away from the 6KL through the metal brackets and into the metal support 6 00 1 00 4 00 i structure A A Since the 6KL has special internal thermal techniques to move the heat generated by the electronic components inside into the case the case may be quite warm to the touch during normal operation TH TT THT 8 00 em Fig 3 3 1a TK Ww Panel Wall Mounting position 1 0 30 The unit is mounted using the brackets as 00 28 shown in the illustration above The spacing for the mounting screws into the
39. ing installation supply circuit to the product 3 This product shall be provided with a maximum 10A DC Listed fuse or circuit breaker in the supply circuit when connected to a 48V centralized source 4 The external power supply for DC units shall be Listed Direct Plug In power unit marked Class 2 or listed ITE Power Supply marked LPS which has suitably rated output voltage i e 24VDC or 48VDC and suitable rated output current 5 Product does not contain user replaceable fuses Any internal fuses can ONLY be replaced by GarrettCom personnel through the RMA process This equipment has the ordering option of being supplied to the purchaser without a Fiber Optic Class 1 Laser transceiver included In this case it is the responsibility of the purchasing party to apply the proper labeling required to the product in accordance with US 21CFR Subchapter J Part 1040 if a transceiver is installed by the purchaser See label example below Complies with FDA radiation performance standards 21CFR Subchapter J Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 Table of Contents Page 1 0 SPECTFICATIONS scccccsccscsscsssscssssssscsscssssssssssssssssssessessessceses 1 1 1 Technical Specifications 00 eecesesceesecseeseceeeeeceeeeeceaecateseeeeeeeaeeetees 1 1 2 Ordering Information eee eceeeeeseeceseceeeeecneeeecaeceessecaeeseeneeeeeas 4 2 0 INTRODUCTION 000 0 ssccccccccscscseecsscncssccncscesescsescs
40. ior to the occurrence of the problem Any changes to system administration procedures should all be noted in this record 6 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a full description of the problem GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete details However if the problem or condition causing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 44 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 6 4 Shipping and Packaging Information Should
41. ises that for substation applications the RJ 45 ports are intended for connectivity to other communication equipment such as routers or telecommunication multiplexers installed in close proximity i e less than 2 meters or 6 5ft to the 6KL It is not recommended to use these ports in substation applications to interface to field devices across distances which could produce high greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6KL passes the 1613specifications for zero packet loss with fiber ports amp with RJ 45 ports used as indicated here 3 2 2 Connecting Twisted Pair CATSe or better UTP or STP The RJ 45 Gigabit ports of the Magnum 6KL can be connected to the media types LOOOBASE T or CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable The CAT 5E or better 100 ohm UTP or shielded twisted pair STP balanced cable is recommended to use when making 1OOOBASE TX connections In either case the max distance for unshielded twisted pair cabling is 100 meters 328 ft The following procedure describes how to connect a 1 OOOBASE T twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 1000BASE T connections require that all four pairs or wires be connected Insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note that even though the conne
42. ished on a port after being lost temporarily e NOTE Some NIC cards only auto negotiate when the computer system that they are in is powered These are exceptions to the negotiate at LINK enabled rule above but may be occasionally encountered When operating in 100Mb half duplex mode cable distances and hop counts may be limited within that collision domain The Path Delay Value PDV bit times must account for all devices and cable lengths within that domain For Magnum 6KL Fast Ethernet switched ports operating at 100Mb half duplex the bit time delay is 5OBT 4 3 Flow control IEEE 802 3x standard Magnum 6KL Switches incorporate a flow control mechanism for Full Duplex mode The purpose of flow control is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port and in other protracted heavy traffic situations Magnum 6KL Switches implement the 802 3x flow control non blocking on Full Duplex ports which provides for a PAUSE packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets The transmitting device is commanded to stop transmitting into the 6KL Switch port for sufficient time to let th
43. lled in a Magnum 6KL Series Managed Switch the copper ports support the standard distance of 100m on each port see Sections 5 1 2 and 5 1 7 for more details 5 1 9 6KL4 4MSC 4MST 4FLST 2FX2FLMST Slot C 4 x SC Multimode or 4 x ST Multimode 5 Haaa Eo S o es z S eo a 3 a 1 The 6KL4 4MSC shown 4 port Fiber module provides four 100Mb Multimode SC Fiber ports This option utilizes a SC type push pull fiber optic connection The 6KL4 4MST 4 port Fiber module provides four 100Mb Multimode ST Fiber ports This option utilizes a ST type twist lock fiber optic connection The 100Mb Multimode SC and ST ports support fiber optic cable distances up to the IEFE standard 100Mbps distance limits typically 2km at full duplex The 6KL4 4FLST 4 port Fiber module provides four 10Mb Multimode ST Fiber ports This option utilizes a ST type twist lock fiber optic connection The 10Mb ST fiber ports allow the user to connect their legacy 10Mb network to the Magnum 6KL Series switch It supports distances according to the 10Base FL standard up to 2km for Multimode fiber The 6KL4 2FX2FLMST 4 port Fiber module provides two 100Mb Multimode www GarettCom com 36 Magnum
44. loating ground DC Power Connector Terminal block 12VDC Power Input nominal range 10 to 15 VDC 24VDC Power Input nominal range 18 to 36VDC 48VDC Power Input nominal range 36 to 60VDC Power Input for PoE PoE 802 3af 48VDC Power Input range 45 to 57VDC add up to 15 watts per PoE port to the base unit power draw Power Input for PoE PoE 802 3at 48VDC Power Input range 52 to 56VDC add up to 25 watts per PoE port to the base unit power draw ww GarrettCom com 2 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 DC Power Supply Internal floating ground 125VDC Power Input nominal range 88 to 150VDC 250VDC Power Input nominal range 160 to 300VDC Std Terminal Block GND AC Power Supply Internal AC Power Connector IEC 320 type male recessed 100 240VAC Power Input 47 to 63 Hz auto ranging Power Consumption 15 watts Max for a fully loaded fiber model with 2Gb 10 watts Max for 8 port copper and 100Mb fiber model Dual DC Power Input Optional A Dual Source option is available for the 12VDC 24VDC 48VDC and 125VDC and 250VDC models This provides for continuity of operation when either of the DC input sources is interrupted See Appendices B and C The Dual Source Terminal Block is marked A A B B Management Console connector RJ45 see details at sec 3 6 6KL Mounting Vertical mounting normal Suitable for wall or DIN Rail mounting Agency Ap
45. luggable open transceiver ports for user selectable SFP Gb transceivers in each Gigabit 1000Mb SFP Small Form Pluggable Transceiver option 6KL SFP GTP Gb SFP transceiver Copper 1000Base T 100m SFP SX Gb SFP transceiver 1OOOMb SX 850nm wavelength 550m SFP ESX Gb SFP transceiver 1000Mb 1310nm wavelength 2Km SFP LX10 Gb SFP transceiver 1OOOMb LX 1310nm wavelength 10Km SFP LX25 Gb SFP transceiver 1OOOMb LX 1310nm wavelength 25Km SFP ZX40 Gb SFP transceiver 1OOOMb ZX 1550nm wavelength 40Km SFP ZX70 Gb SFP transceiver 1OOOMb ZX 1550nm wavelength 70Km ig Cc i S Slot C S SS SS Se NY F fa B 1000 a onoo eg lt a S BAZA 7 i ii i Slot B 1 om PS GE BATT a Seer mo iF a UAZ it FM 10 aig O 7 i d 10 f PWR MNS 6K License MNS 6K managed software is pre loaded from the factory S RING Key S Ring and RS Ring Redundancy Manager licensed software for redundant ring management One S Ring or RS Ring key is for licensed use one 6K managed self healing Ring CONSOLE CBLQD Console attachment cable Serial null modem aka X modem cable with RJ45 connector for the 6KL on one end and a DB 9 connector on other end CONSOLE CBLQU Same a
46. m and the Cable Loss for 9 125 Single mode is 0 5 dB km and the Cable Loss for 9 125 Single mode is 0 4 dB km LX25 and the Cable Loss for 9 125 Single mode is 0 25 dB km ZX40 and the Cable Loss for 9 125 Single mode is 0 2 dB km ZX70 See http www garrettcom com techsupport power_budget pdf for more information on Power budget calculations 5 0 Magnum 6KL Managed Edge Switch Port Modules This chapter describes each Port Module PM including appearance functionality and status displays 5 1 6KL Modules An important feature of the Magnum 6KL is the use of Port Modules for flexible mixed media connectivity to RJ 45 copper and various fiber media The first four ports 1 2 3 amp 4 of the Magnum 6KL Switches are fixed RJ 45 copper ports with dual speed 10 100Mbps auto negotiating capability Additionally the switch can accept up to two Port Modules to provide the user with up to 6 additional ports 10 total providing a wide selection of Ethernet copper and fiber media connections with 10 100 and 1000Mbps capability and up to 70km Note The 6KL Port modules are not identical to the port modules used in other 6K products such as the 6K25e and 6K16V For information about other 6K products please see the applicable manual For a list of 6KL Port Modules refer to Section 1 2 Each 6KL Port Module PM is individually described in the following sections 30 Magnum 6KL Managed Edge Switch I
47. mode at 10Mb or 100Mb Half Full Duplex managed switch or not No cross over cable is required while using the 6KL s copper port to other devices Operation is according to the IEEE 802 3u standard The Managed 6KL s Fast Ethernet copper ports can be set for either fixed 100Mb speed or for 10 100 F H N way auto negotiation per the IEEE802 3u standard The selection is made via MNS software The factory default setting is for auto negotiation At 10Mb or 100Mb fixed speed the user may select half or full duplex mode by MNS Software for each RJ 45 port separately For detail information See Section 2 3 of this manual for information to access the 6K MNS Software user guide One frequently used application for the Managed Magnum 6KL Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone or to some other remote 100Mb device In this case it is desirable to operate the fiber link at 100Mb speed and at either half or full duplex mode depending on the capabilities of the remote device Standard commercially available Fast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at the 100Mb fixed speed Attachments to a 10 100 auto negotiation port typically will not work properly The 6KL Switch s RJ 45 ports handle this situation by configuring the ports as per desired through MNS software port se
48. nd 802 1p QoS Traffic Prioritization Magnum 6KL switches are plug and play and are designed for use in connecting edge devices such as PLCs IEDs and PoE video cameras with upstream switches and routers where a mix of bursty data traffic and priority streaming traffic for video surveillance and cell tower applications are present Magnum 6KL Managed Edge Switches have heavy duty steel cases and are readily available with standard Industrial grade 24VDC power Alternative internal DC power options are available Internal AC power and DC power input types may be 12V 24V 48V 125V 250V and dual source DC input is optional on the 6KL Alarm Relay contacts provided on each Magnum 6KL Switch monitor the hardware and software through traps providing a record of any losses of power signals and other user defined software events See Section 3 5 for details 2 2 1 Packet Prioritization 802 1p QOS Quality of Service means providing consistent predictable data delivery to users from datagram paths that go all across a network As a LAN device the Magnum 6KL can do its part to prevent any QOS degradation while it is handling Ethernet traffic through its ports and buffers The Magnum 6KL switching hardware supports the IEEE 802 1p standard and fulfills its role in support of QOS giving packet processing priority to priority tagged packets according to the 802 1p standard In addition to hardware support for QOS the MNS software R2 supports two p
49. nstallation and User Guide 05 12 5 1 1 6KL Module LED designations PWR LED ON when Power is being supplied to the unit 1 2 RJ45 Standard 1 ON 100Mb OFF 10Mb 2 ON Link BLINKING Activity N 3 ON Full Duplex OFF Half Duplex e 3 1 2 RJ45 PoE 1 ON 100Mb OFF 10Mb 2 ON Link BLINKING Activity UN 3 ON Full Duplex OFF Half Duplex E 4 ON PoE device detected 3 4 1 2 Gigabit Port Copper 1 ON 10Mb Link BLINKING Activity 2 ON 1000Mb Link BLINKING Activity N 1 2 ON 100Mb Link Blinking Activity 31 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 MTRJ Fiber ia 1 ON Link BLINKING Activity 2 ON Full Duplex OFF Half Duplex Nh N 2 ON Full Duplex OFF Half Duplex 72 0 4 LC Fiber 1 ON Link BLINKING Activity SC Fiber 1 ON Link BLINKING Activity 2 ON Full Duplex OFF Half Duplex TX RX ST Fiber 1 ON Link BLINKING Activity 2 ON Full Duplex OFF Half Duplex SFP Gigabit Port Fiber Copper l 1 ON Link BLINKING Activity as A 1 NO Nh q 32 M
50. nstallation and User Guide 05 12 5 1 3 6KL4 4MLC 4 x Multimode LC Slot C Tale Fume Zaa m The 6KL4 4MLC 4 port Fiber module provides four 100Mb Multimode LC iL Fiber ports The 6KL4 4MLC fiber ports are Small Form Factor SFF LC Multimode connectors used primarily in 100Mbps fiber to the desktop links When installed in a La a Fal Beoeo Magnum 6KL Series Switch it supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits i e typically 2km at full duplex and 412m at half duplex The compact size of the LC Connector reduces the size of wiring panels in wiring closets while providing the advantage of future proof fiber optic technology The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being received 5 14 6KL4 4SLC 6KL4 4SLCL 4 x Singlemode LC Slot C The 6KL4 4SLC 4 port Fiber module provides four 100Mb Singlemode LC Fiber ports supporting distances up t
51. num 6KL switching hardware supports QoS giving packet processing priority to priority tagged packets according to the IEEE 802 1p standard For port and application specific priorities of data the QoS software may be configured Fiber Ports Built In Magnum 6KL Managed Edge Switches are designed to naturally include fiber ports and support mixes of multi mode single mode 100Mb and 1000Mb speed full and half duplex classic Small Form Factor SFF and Small Form Pluggable SFP fiber connectors RJ 45 10 100 ports can also be configured in the mix of port types Relay Contacts for monitoring internal power and user defined software events Two Alarm Relay contacts monitor basic operations One is for hardware and will signal loss of power internally The other is software controlled and will signal user defined software events such as a security violation or an S Ring fault condition Vertical mounting for efficient convection cooling no fans extended temperature Mounting brackets for vertical mounting are included DIN Rail mounting hardware is optional All types of power input 12 24 48 125 250VDC and AC The 6KL can be configured with the user s choice of DC power supplies 12V and 24V for factory floor 48V for tariffed carrier field facilities and for POE powered applications such as IP video surveillance and 125V or 250V for substations An internal AC power supply may also be chosen universal AC for use worldwide Heavy d
52. o 20km This module provides the same functions as the Multimode version see Section 5 1 3 for more details The 6KL4 4SLCL 4 port Fiber module provides four 100Mb Singlemode LC Long Reach Fiber ports supporting distances up to 40km This module provides the same functions as the Multimode version see Section 5 1 3 for more details 5 1 5 6KL4 2MLC2RJ 2 x Multimode LC 2 x RJ45 Slot C 20000 ana fa am at a The 6KL4 2MLC2RJ 4 port Fiber Copper module provides two 100Mb Multimode LC Fiber ports and two 10 100Mb switched RJ 45 ports 34 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 The Multimode LC ports support fiber optic cable distances up to the IEEE standard 100Mbps distance limits typically 2km at full duplex The 6KL4 2MLC2RJ copper ports support Ethernet twisted pair segments of any standard length It is equipped with a two port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections When installed in a Magnum 6KL Series Managed Switch
53. o gt arrettGom A BELDEN BRAND Magnum 6KL Managed Edge Switch N s Me S 3 Hardware Installation and User Guide Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 Magnum 6KL Managed Edge Switch Hardware Installation and User Guide Part 84 00184Z Rev F Trademarks GarrettCom is a registered trademark and Magnum Dymec DynaStar Personal Switch Link Loss Learn S Ring Convenient Switch and Converter Switch are trademarks of GarrettCom Inc Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important The Magnum 6KL Managed Edge Switch contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void If problems are experienced with Magnum 6KL Switch products consult Section 6 Troubleshooting Copyright 2009 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 7437 Phone 510 438 9071 Fax 510
54. ock B5 0 OPERATION Operation of Magnum 6KL Switches with the optional 48VDC 12VDC 24VDC 125VDC or 250VDC dual source power input is identical to that of the standard single source DC powered models B6 0 TROUBLESHOOTING Please refer to Section 6 0 for troubleshooting 48 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 APPENDIX C Internal DC Dual Source Power Input Option C1 0 SPECIFICATIONS FOR MAGNUM 6KL EDGE SWITCH Power Supply Internal 48VDC Dual Source DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 36 60 VDC Power Supply Internal 12VDC Dual Source model Dual Src 12V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 10 15 VDC Power Supply Internal 24VDC Dual Source model Dual Src 24V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 18 36 VDC Power Supply Internal 125VDC Dual Source model Dual Sre 125V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at 88 150 VDC Power Supply Internal 250VDC Dual Sourc
55. own the unit Individual cable segments can be connected or disconnected without concern for power related problems or damage to the unit Power input options are available to suit the 6KL Switches to special high availability communications and or heavy industrial grade applications including 12VDC 48VDC 24VDC 125VDC and 250VDC with single DC input 12VDC 48VDC 24VDC 125VDC and 250VDC with dual source DC input AC input with internal power supply see Section 1 2 for Ordering Information Fig 3 4a Single DC power input Power input connection made with 4 position terminal block NC NC Not connected Fig 3 4b Dual DC power input Power input connection made with 4 position terminal block A A B B Fig 3 4c AC power input Power input connection made with IEC 320 type male recessed 24 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 3 5 Alarm Contacts for monitoring internal power and Software Traps The Alarm Contacts feature standard on Magnum 6KL s provides two Form C Normally Closed NC contacts to which the user can attach two sets of status monitoring wires at the green terminal block The first NC Alarm Contact is a Software Alarm labeled S W operated by user settings in the MNS 6K software The user can disable the Software Alarm feature with a software configuration command if desired When the Software Alarm is enabled the Form C Normally Close
56. provals and Standards Compliance UL listed UL60950 cUL CE Emissions meet FCC Part 15 Class A NEBS Level 3 and ETSI Compliant IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Power Substations in Section 3 2 1 3 6 1 and 5 1 2 IEC 61850 EMC and Operating Conditions Class C for Power Substations NEMA TS 2 and TEES for DC powered and PoE powered traffic control equipment Warranty Three years per UL 60950 temperature rating Made in USA Email info GarrettCom com for additional information Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 1 2 Ordering Information MODEL DESCRIPTION Magnum 6KL 24VDC Magnum 6KL Managed Edge Switch base unit with four 10 100 copper ports Up to 4 100Mb fiber ports or up to four more 10 100 copper ports or combinations may also be configured and up to two Gb ports are optional Heavy duty metal case IP52 for environmental protection no fans For licensed managed networks software MNS 6K RS Ring and S Ring including GUIs for ease of use and industry leading security features see separate data sheets Magnum 6KL 12VDC Same as 6KL 24VDC except the power input is 12VDC Magnum 6KL 48VDC Same as 6KL 24VDC except the power input is 48 VDC Magnum 6KLP 48VDC PoE same as 6KL 48VDC except the four 10 100 ports are PoE 802 3af enabled data pairs Magnum 6KL 125VDC Same as 6KL 24VDC except the power input is 125VDC Magnum 6KL 250VDC Same
57. r ports 6KL4 2SSC2RJ adds two SM 20Km 100Mb SC fiber and two 10 100 copper ports 6KL4 4SSCL adds four SM 40Km 100Mb SC fiber ports 6KL4 4MST adds four MM 2Km 100Mb ST fiber ports 6KL4 2MST2RJ adds two MM 2Km 100Mb ST fiber and two 10 100 copper ports 6KL4 4FLST adds four MM 2Km 10Mb ST fiber ports 6KL4 2FX2FLMST adds two MM 2Km 100Mb and two MM 2Km 10Mb ST fiber ports 6KL4 2SL2MLC adds two SM 20Km 100Mb LC fiber and two MM 2Km 100Mb LC fiber ports 6KL4 1SL3MLC adds one SM 20Km 100Mb LC fiber and three MM 2Km 100Mb LC fiber ports 6KL4 IMLISLC2RJ adds one MM 2 Km 100Mb LC fiber one SM 20Km 100Mb LC fiber and two 10 100 copper ports 6KL4 IMLC3RJ adds one MM 2Km 100Mb LC fiber and three 10 100 copper ports 6KL4 1SLC3RJ adds one SM 20Km 100Mb LC fiber and three 10 100 copper ports 6KL4 1SLCL3RJ adds one SM 40Km 100Mb LC fiber and three 10 100 copper ports 6KL4 1MT3RJ adds one MM 2Km 100Mb MTRJ fiber and three 10 100 copper ports 6KL1 1MLC adds one MM 2Km 100Mb LC fiber port 6KL1 1SLC adds one SM 20Km 100Mb LC fiber port 6KL1 1SLCL adds one SM 40Km 100Mb LC fiber port 6KL1 IMT adds one MM 2Km 100Mb MTRJ fiber port MM2 Multi mode fiber SME Single mode fiber _ www GarrettCom com ss 5 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 Following modules can be configured in Slot B only Magnum 6KL Slot B Gigabit Port Modules 6KL 2GCU adds two auto negotiating 10 100 1000Mb copper ports 6KL 2GSFP adds two SFP p
58. ring topology The Gigabit port option boosts the bandwidth for high speed to support the peak traffic and minimize congestion Example 3 In another application in an industrial environment a 12 port Nebs compliant 24VDC managed switch is required to meet the fiber and copper connections to cover the wider area of video CCTV The switch must be SNMP enabled and managed to easily monitor the whole setup The Magnum managed edge switch easily qualifies for this requirement with the various features and modularity it has Loaded with MNS 6K management software the edge switch provides a very effective and economical solution for the video vignette environment The security features e g port security VLANs SNMPv3 secure telnet etc also boost the Magnum managed switches to provide a very effective and reliable solution The modularity feature to support both copper and fiber at either 10 100 1000Mb speeds easily meets the various speeds of legacy and future broadband requirements In a fast growing secure video environment the 6KL is a reliable and secure solution The modular design of the Magnum 6KL provides a wide range of copper fiber options to meet requirements The Gigabit uplink for storage or broadband uplink allows the telecom user a very effective solution to store their sensitive data securely Magnum 6K16 2 side by side CCTV Camera CCTV Camera Fig 2 5c Magnum 6KL deployed in a video security CCTV application for
59. riority queues that can be shared across the eight levels of defined packet priorities for application specific priority control by the user through software configuration settings Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 2 2 2 Frame Buffering and Flow Control Magnum 6KL s are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC i e are good packets This eliminates the propagation of bad packets enabling all of the available bandwidth to be used for valid information While other switching technologies such as cut through or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscriminate cut through forwarding is greater traffic congestion especially at peak activity Since collisions and bad packets are more likely when traffic is heavy the result of store and forward operation is that more bandwidth is available for good packets when the traffic load is greatest When the Magnum 6
60. rom accidental damage in a lab or workplace setting Maintain an open view of the front to visually monitor the status LEDs Keep an open area around the unit so that cooling can occur from convection while the unit is in operation The 6KL has no fans so it is silent when in operation Internal electronics use the case as a heat sink so the unit may normally be quite warm to the touch 17 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 3 2 Connecting Ethernet Media The Magnum 6KL Switches are specifically designed to support standard Ethernet media types within a single Switch unit This is accomplished by using four popular Fiber Connectors which can be individually selected and configured See Section 5 1 for a description of the Modules The various media types supported along with the corresponding IEEE 802 3 802 3D 802 3u 802 3AB and 802 3z standards and connector types are as follows Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Twisted pair CATSE or CAT6 1000BASE T RJ 45 Fiber Multi mode 10BASE FL ST Fiber Multi mode 100BASE FX MTRJ LC SC ST Fiber Single mode 100BASE FX LC SC Fiber Multi mode 1000BASE SX LC SFP Fiber Multi mode Single mode 1000BASE LX LC SFP Fiber Single mode 1000BASE ZX LC SFP See http www garrettcom com techsupport power_budget pdf for Power budget calculations to find fiber cable distanc
61. s multiple site offices and factory floors The different locations can be easily connected together with the Fiber ports supported by the Magnum 6KL Switch A main NT server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port Magnum 6K32 es SNMP Monitor one eT AGa ih Fiber connection Jais other building Factory Floor PLC Factory Floor PLC Factory Floor PLC Fig 2 5a The industrial factory floor application with Magnum 6KL 14 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 Extended temperature ratings and a variety of options for AC DC power supplies qualify this managed 6KL switch for use in non temperature controlled networks and many other temperature sensitive critical Industrial applications where above normal room temperatures occur while the network is in operation Full duplex future proof fiber media can easily connect long distance subnets and provide a stable secure network to all applications The SNMP management capability of the Magnum 6KL Switch helps create a database of all the network subnets to easily manage the network Example 2 A managed network is needed to provide a redundant ring topology for maximum redundancy In a network where any faulty cable cable disconnection or power failure can bring the whole thing down a ring switch can be reconfigured and up and running in milliseconds The ring
62. s above but with USB connector DIN RAIL 6KL Din Rail mount for a secure vertical mount with screws for 6KL DUAL SRC Two separate power inputs 12 24 48 125 or 250VDC CONFORM05 CRM Conformal coating heavy duty silicone at 5 mil thickness for interior PCBs PS and modules for moisture protection CONFORM08 CRM Conformal coating heavy duty silicone at 8 mil thickness for interior PCBs PS and modules for oil and gas industry Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 2 0 INTRODUCTION 2 1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product notify the carrier of any damage that you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 Magnum 6KL Managed Edge Switch base unit configured with user selected port module options installed 2 Set of two metal vertical mounting brackets with screws to the case 1 6KL Installation and User Guide this manual Remove the items from the shipping container Be sure to keep the shipping container should you need to re ship the unit at a later date In the event there are items missing or damaged contact the party from whom you purchased the product If the unit needs to be returned please use the original shipping container if possible Refer to Section 6
63. see Section 1 2 for the SFP s available for the 6KL Note It is highly recommended to remove the fiber cable first before removing the SFP transceiver for any reason Not removing the fiber cable first can damage the fiber cable cable connector or optical interfaces It is advised not to remove and insert a SFP transceiver frequently as this may shorten its useful life Note Always use an ESD wrist strap while handling the SFP transceivers since the SFP modules are static sensitive devices Note The copper 1000BASE T SFP transceiver port supports 1000Mb only It is recommended to use a straight through RJ 45 4 twisted pair connection while connecting to any Server workstation While connecting with any Switch repeater or other device it is recommended to use Crossover RJ 45 4 twisted pair category 5 or higher cabling The maximum length supported on copper 1OOOBASE T is 100m 328 ft 3 2 5 Connecting Fiber Optic Cable to SFP Transceivers 1 Before connecting the fiber optic cable remove the protective dust caps from the tips of the connectors on the PM Save these dust caps for future use 2 Wipe clean the ends of the dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of
64. sign enables the unit to operate in harsh Industrial grade environments and achieves high EMI noise immunity Heavy duty Ethernet Switch jobs are readily accommodated with an extended temperature rating of 40 C to 60 C by the UL Component Parts method or 40 C to 85 C by the IEC 60068 Type Test method With options such as several popular DC power input types AC power and DIN Rail mounting the hardened Magnum 6KL is a multi purpose Industrial Ethernet Switch Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 The 6KL managed switches also provides a PoE option via power inside PoE base unit 6KLP 48VDC on Slot A and allows the users to utilize up to 4 ports of PoE to support 802 3af Powered devices See details for PoE base unit in sec 5 1 11 The Power Sourcing Equipment PSE is fully compatible with Powered Devices PD e g wireless access points IP phones that comply with the IEEE 802 3af PoE standard The PoE switch ports have an auto sensing algorithm so that they provide power only to 802 3af PoE end devices PoE is managed by a multi stage handshake to protect equipment from damage and to manage power budgets The PoE ports will discontinue supplying power when the PoE powered devices are disconnected This feature supports the 802 3af PoE PSE standard for over current protection under current detection and fault protection High performance features include non blocking unicast traffic speed on all ports a
65. sses are on the same port segment will be filtered constraining them to that one port and relieving the rest of the network from having to process them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Traffic needed for maintaining the un interrupted operation of the network such as occasional multi cast packets is forwarded to all ports The Magnum 6KL Switches operate in the store and forward switching mode which eliminates bad packets and enables peak performance to be achieved when there is heavy traffic on the network Address Learning All Magnum 6KL units have address table capacities of 8K node addresses suitable for use in larger networks They are self learning so as nodes are added removed or moved from one segment to another the 6KL Switch automatically keeps up with node locations An address aging algorithm causes least used addresses to fall out in favor for frequently used addresses To reset the address buffer cycle power down and up 27 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 4 2 Auto Cross MDIX and Auto negotiation for RJ 45 ports The RJ 45 ports independently support auto cross MDI or MDIX in auto negotiation mode and will work properly with all the other connected devices with RJ 45 ports whether they support Auto negotiation e g 10Mb Hub media converter or fixed
66. ssnessssnessossessesees 7 2 1 Inspecting the Package and Product eeeceescecsseceeececeteceeeeceeeeeenees 7 2 2 Product Description Magnum 6KL Managed Edge Switch 8 2 2 Packet Prioritization 802 1p QOS eee ceeeesseceeneecsseceeeeeenaeeeeees 9 2 22 Frame Buffering and Flow Control ce eeeeceseeceesecseeeeeneeeees 10 2 3 Managed Network Software for Magnum 6KL eeeeeeeeeeeeeeees 11 2 4 Features and Benefits 0 0 0 ee eessseseecseeeecnceeeceseceeesecaecateseceseeeaeeees 12 29 sAppliCatOns scree peni einean eoa re SE R ESEE OaE ar OEE gemstones 13 3 0 INSTALLATION sssccssooscsccsscsscncssscncscossscsescsssesssssncssssnessossessesees 17 3 1 Locating Magnum 6KL Switches 0 0 eeeeeeeeseeeeceeeeeeeseeaeeeeneeeees 17 3 2 Connecting Ethernet Media 0 cece eeeseseesecseeeeceseeeesaeeeeesecaeeseeneees 18 3 2 1 Connecting Twisted Pair CAT3 CATS UTP or STP 18 3 2 2 Connecting Twisted Pair CATSe or better UTP or STP 19 3 2 3 Connecting Single Mode Fiber Optic eseeeeseereereereererrerereen 19 3 2 4 Gigabit SFP Small Form factor Pluggable Transceivers 20 3 2 5 Connecting Fiber Optic Cable to SFP Transceivers 5 20 3 3 DIN Rail Mounting the Magnum 6KL owe cece cete cee eneeeeee 21 3 3 1 Mounting Dimensions for 6KL with metal brackets 22 3 4 Powering the Magnum 6KL Managed Edge Switch 24 3 5 Alarm Contacts for monitoring in
67. sssessessceees 45 APPENDIX B DC Power Input eesseseosossessessesccsosscecossesoossescssoeseesossessoessse 46 APPENDIX C Internal DC Dual Source Power Input Option 49 Revisions Rev F 05 12 Added PoE module C removed module install instructions Rev E 11 09 Updated Copper Gigabit Port LED designations pg 31 Rev D 10 09 Updated Sec 1 1 pg 2 and Sec 3 2 pg 18 to include SC and ST fiber connectors Rev C 10 09 Added photos to Appendix D Rev B 09 09 Added additional module options changed Copper Gb LED configuration see 5 1 1 Rev A 07 09 Initial Release Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 1 0 SPECIFICATIONS 1 1 Technical Specifications Performance Filtering Forwarding Rate Ethernet 10Mb 14 880 pps Fast Ethernet 100Mb 148 800 pps Gigabit Ethernet 1000Mb 1 488 000 pps Switching Processing Type Store and Forward with IEEE 802 3x full duplex flow control non blocking Data Rate 10Mbps 100Mbps and 1000Mbps Address Table Capacity 8K node self learning with address aging Packet buffer size 128 KB total Latency 6us packet time max TX TX TX FX FX FX TX G G G Throughput with 8 10 100 and 2Glink max 4 17M pps Transmit Back plane 2 66Gb s per slot Network Standards and Compliance hardware Ethernet V1 0 V2 0 IEEE 802 3 10BASE T IEEE 802 3u 100Base TX 100BASE FX IEEE 802 3z 1000BASE X Ethernet Auto negotiation IEEE 802 3ab 1OOO
68. t Fiber Copper module provides two 100Mb Multimode ST Fiber ports and two 10 100Mb switched RJ45 ports This option utilizes a ST type twist lock fiber optic connection ih A ro a aeoe The 6KL4 2MSx2RJ copper ports support Ethernet twisted pair segments of any standard length It is equipped with a two port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections When installed in a Magnum 6KL Series Managed Switch the copper ports support the standard distance of 100m on each port see Sections 5 1 2 and 5 1 9 for more details 37 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 5 1 12 6KL4 2SSC2RJ Slot C 2 x SC Singlemode 2 x RJ45 The 6KL4 2SSC2RJ 4 port Fiber Copper module provides two 100Mb Singlemode SC Fiber ports and two 10 100Mb switched RJ45 ports This module provides the same functions as the Multimode version see Section 5 1 11 for more details 5 1 13 6KL4 2SL2MLC 6KL4 1SL3MLC Slot C
69. ternal power and Software Traps 25 3 6 Connecting the Console Terminal to Magnum 6KL eee 26 3 6 1 RJ45 Console port Serial port pin assignments 0 eee 26 4 0 OPERATION 0 cssccscssccssccsccscescssssesssencsscsscecssesssessssncssessessesseseoss 27 4 1 Switching Functionality 0 0 00 cee ceesecseeseesecseeeeceeeeeesaeeeeesecaeeseeneees 27 4 2 Auto Cross MDIX and Auto negotiation for RJ 45 ports 28 4 3 Flow control IEEE 802 3 standard ccccssessecececeesenseceeeeeeeenes 29 4 4 Power Budget Calculations for 6KL Modules with Fiber Media 30 5 0 Magnum 6KL Managed Edge Switch Port Modules sssesee 30 5 1 GIL MOUS cascsscsscssusssscesucesscnsuendanvsdbaadsosisestesshseaacseussonesuabboinsepscantens 30 5 1 1 6KL Module LED designations 0 0 00 eee eee eee cee ceeeeeeeeeeee 31 5 1 2 6KL4 RJ45 4x 10 100Mb RJ45 Slot C seeen 33 5 1 3 6KL4 4MLC 4 x Multimode LC Slot C 34 5 1 4 6KL4 4SLC 6KL4 4SLCL 4 x Singlemode LC Slot C 34 5 1 5 6KL4 2MLC2RJ 2 x Multimode LC 2 x RJ45 Slot 34 5 1 6 6KL4 2SLC2RJ 6KL4 2SLCL2RJ Slot C esseere 35 5 1 7 6KL4 4MTRJ 4 x Multimode MTRJ Slot C oo eee eee 35 5 1 8 6KL4 2MT2RJ 2 x Multimode MTRJ 2 x RJ45 Slot C 36 5 1 9 6KL4 4MSC 4MST 4FLST 2FX2FLMST Slot C 36 5 1 10 6KL4 4SSC 6KL4 4SSCL Slot C oo eeeceseeeeeseeneeeeeeeeees 37 iii Magnum 6KL Managed Edge Switch Installation
70. the fiber optic segment 20 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 3 Find the Transmit TX and Receive RX markings on the SFP transceiver to verify the top side of it 4 Position the SFP transceiver correctly before insertion and then insert the SFP transceiver carefully until the transceiver connector snap into the place in the socket connector 5 Connect the Transmit TX port on the Magnum PM to the Receive RX port of the remote device Connect the Receive RX port on the PM to the Transmit TX port of the remote device The LINK LED on the front of the PM will illuminate and turn Green when a proper connection has been established at both ends and when power is ON in the unit If LINK is not lit or OFF after cable connection the normal cause is improper cable polarity Swap the fiber cables at the PM connector and also check the connectivity on the target device to remedy this situation Reconfigure or reboot both of the devices if required If connected properly you can check via MNS 6K software for verifying the validity of SFP Gigabit ports 3 3 DIN Rail Mounting the Magnum 6KL The Magnum 6KL is designed for use in a factory floor industrial environment It is available with an optional DIN Rail bracket to mount it securely in a metal factory floor enclosure maintained vertically for proper convection cooling of the unit The Magnum 6KL requires one DIN Rail bracket for sec
71. ts i e typically 2km at full duplex and 412m at half duplex The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being received _ www GarrettCom com ss ss 35 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 5 1 8 6KL4 2MT2RJ 2 x Multimode MTRJ 2 x RJ45 Slot C oS im a mira oF st The 6KL4 2MT2RJ 4 port Fiber Copper module provides two 100Mb Multimode MTRJ Fiber ports and two 10 100Mb switched RJ 45 ports The Multimode MTRJ ports support fiber optic cable distances up to the IEEE standard 100Mbps distance limits typically 2km at full duplex Aoeoe The 6KL4 2MT2RJ copper ports support Ethernet twisted pair segments of any standard length It is equipped with a two port RJ 45 connector and offers 10 100 full half duplex auto negotiating capability on each port The RJ 45 connector is shielded to minimize emissions and will allow both unshielded twisted pair UTP and shielded twisted pair STP cable connections When insta
72. ts will still operate properly for data traffic to non PoE devices 41 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 5 1 22 6KL 2GCU 2 x Gigabit RJ45 Slot B oo im cone ES i QZee2oa2 at The 6KL 2GCU 2 port Copper Gigabit module provides two fixed 10 100 1000Mb RJ45 ports in slot B There are two LEDs provided for each Gigabit port Each Copper Gigabit port has LEDs that indicate L A Link Activity 10 100 and 1000Mbps speed set to AUTO by default 5 1 23 6KL 2GSFP 2 x Gigabit SFP Slot B D fim fat far Ta The 6KL 2GSFP 2 port Fiber Gigabit module provides two SFP open transceiver locations Transceivers are available with both multi mode 850nm 550m 1310nm 2km single mode 1310nm 10km and 25km and single mode 1550nm 40km and 70km fiber options see Sec 1 2 of this manual for available part numbers The 1000Mb Gigabit SFP fiber port modules on the Magnum 6KL are normally set factory default to operate at AUTO mode for best fiber distance and jeooo performance Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being received 42 Magnum 6KL Managed
73. ttings and can check the port status of each port after the change When Magnum 6KL RJ 45 copper ports are set for auto negotiation and are connected to another auto negotiating device there are 4 different speed and F H modes possible depending on what the other device supports These are 1 100Mb full duplex 2 100Mb half duplex 3 10 Mb full duplex and 4 10 Mb half duplex The auto negotiation logic will attempt to operate in descending order and will normally arrive at the highest order mode that both devices can support at that time Since auto negotiation is potentially an externally controlled process the original highest order mode result can change at any time depending on network changes that may occur If the device at the other end is not an auto negotiating device the 6KL s RJ 45 ports will try to detect its idle signal to determine 10 or 100 speed and will default to half duplex at that speed per the IEEE standard General information Auto negotiation per port for 802 3u compliant switches occurs when the devices at both ends of the cable are capable of operation at either 10Mb or 100Mb speed and or in full or half duplex mode and can send receive auto negotiation pulses and the second of the two connected devices is powered up i e when www GarrettCom com 28 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 LINK is established for a port or the LINK is re establ
74. urce Terminal block gt C5 0 INSTALLATION This section describes the proper connection of the 48VDC 12VDC 24VDC 125VDC and 250VDC dual source leads to the power terminal block on the Magnum 6KL Switch shown in Figure above The terminal block is located on the left front of the unit next to the Alarm terminal block and is equipped with four 4 screw down lead posts The primary terminals are identified as positive A 50 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 negative A and the secondary power terminals as negative B positive B The chassis is earth ground GND Note The GND should be hooked up first The 6KL unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting live power lines to the terminal block always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more ve potential The more ve voltage lead from a ve or ve power supply must be connected to the post labeled The connection procedure is straightforward Simply connect the DC leads to the Switch s power terminals positive and negative screws The use of Ground GND is optional it connects to the Switch chassis Ensure that each lead is securely tightened C6 0 ORDERING INFORMATION FOR DUAL SOURCE POWER To order the optional Dual Source power supply fa
75. ure mounting See a 6KL viewed from the bottom at the rear showing the DIN Rail in place The DIN Rail bracket is mounted to the bottom of the 6KL unit as shown Four threaded holes are provided on the bottom of the 6K for DIN Rail mounting purposes The required four screws are included with the DIN Rail bracket and are no 4 40 x 9 32 PHIL PAN Head The rail clip is spring loaded with a pull up latch at the top for easy snap on attachment and removal To install the 6KL with the DIN Rail bracket installed hold the 6KL in the side vertical position with the bottom out and with the top moved in toward the DIN Rail Position the DIN bracket over the top of the DIN Rail Then snap the bracket into holding position by moving the bottom of the 6KL inwards to a vertical position The DIN Rail bracket is heavy duty and will hold the 6KL securely in position even with cabling attached to the unit _www GarettCom con sas 21 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 To release the 6KL from the DIN Rail mounting push the spring loaded slide down until the unit release from the DIN rail disengaging the DIN rail bracket from the DIN rail Once the bottom of the 6KL is rotated out the DIN Rail bracket is not engaged and the 6KL can be moved up and out free of the DIN Rail mounting The DIN Rail mounting bracket is optional and needs to be ordered as separate items e g Model DIN RAIL 6KL 3 3 1 Mount
76. uty design for Industrial Ethernet and extended temperature operation Fiber ports take more power than copper ports but the Magnum 6KL design provides for this with heavy duty components The ambient temperature dual rating is 60 C per UL methods and 85 C per IEC type test methods MNS 6K licensed Management Software Managed Networks Software MNS basic version combined with a Magnum 6K Series Switch provides power and efficiency in a managed Ethernet platform A full range of industry standard software functions in the MNS 6K software product enables the versatile Magnum 6K Switches to perform efficiently in a wide range of managed LAN applications including redundant topologies MNS 6K SECURE optional for extra security Magnum MNS 6K SECURE software is designed for those customers demanding extra security in their networks MNS 6K SECURE is an optional item licensed per switch All of the features in regular MNS 6K are included plus extra security 12 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 E S Ring and Link Loss Learn for economical high availability using ring topology S Ring combined with the Link Loss Learn feature provides reliable fast recovery of a fault in an economical ring topology combining unmanaged and managed switches E RSTP 2004 for rings and meshes fastest fault recovery interoperability RSTP 2004 provides reliable fast recovery from a fault in a redundant LAN which may include M
77. w garrettcom com techsupport sw_downloads 6k new htm For additional information about MNS 6K see the Magnum MNS 6K Software User guide in pdf format a separate document normally accessible via your web browser at ftp ftp garrettcom com or FTP client program at ftp GarrettCom com using user m6kuser password m6kuser All MNS 6K software information and the documentation related to MNS 6K and MNS 6K SECURE software can be accessed at GarrettCom s FTP site Alternatively for the latest documentation and information or needed GarrettCom s MIBs for SNMP visit www GarrettCom com techsupport index htm software and look for the Magnum MNS 6K info For interactive training software which shows basic and advanced info about the Magnum MNS 6K management software and for a useful tool for first time users visit Magnum MNS 6K Operator Training You may also email info GarrettCom com for further information 11 Magnum 6KL Managed Edge Switch Installation and User Guide 05 12 2 4 Features and Benefits Managed switching for high performance Ethernet LANs Magnum 6KL Switches provide unicast non blocking all ports can run at full speed at once performance with standard Managed Network Software They are typically used in LAN traffic centers with up to 8 100Mb 2 Gigabit ports for backbone connections where managed network services are desired Switching services includes 802 1p QoS packet prioritization The Mag