Home

to see directions for installation in Instruction booklet

image

Contents

1. 4 Adjust the unit so that the water level is a 42 from the brim of the surface skimmer 5 Soak the strainer in water and make sure there is no bubble remain underneath the strainer The strainer should float easily If water doesn t flow into the strainer softly press the strainer down in water and release 6 Carbon dioxide set up There are many ways to provide carbon dioxide to the pump If there are any concerns MAINTENANCE Pump Preventing debris and free floating material from entering your Rio Power COs is of utmost importance to the longevity of your pump Your pump requires regular cleaning to maintain a steady water flow Note Gravel sand and calcium deposits will also diminish damage the longevity of Rio Power CO2 and impeller 1 IMPORTANT You must disconnect all electrical power to the aquarium and water pump before beginning the maintenance on any electrical equipment including Ric Power CO2 2 Disconnect the silicone airline tubing from the pump 3 Do not use any soap or detergents Remove the surface skimmer and strainer Remove the COz reaction chamber Rinse and clean sponge Remove the impeller well cover Caution when removing the impeller be careful that you do not misplace the rubber bushings that are 9 B a a h Strainer 7 in the initial set up always consult your local tropical fish store prior to installation Follow all manufactures guidelines and precautions wh
2. Suction cup bracket 9 Magnet mount 10 Flare discharge 11 Air stopper 12 Surface skimmer 13 Flow control collar 14 Strainer CO source is not included NOTE Package will only include either suction cup bracket or magnet mount GFCI Ground Fault circuit Interpreter electrical outlet Do not operate if wire is damaged Do not plug into an extension cord Failure to use the main housing strainer and or filter conversion kif may allow sand and or debris into the impeller chamber thus causing permanent damage fo the impeller ceramic shaft and or the pump Do not plug into a power strip Always plug the pump directly to a GFCI outlet using a drip loop Rio Power COs is designed to run completely submerged in water Do not operate pump outside of water This pump should be submerged in water before connecting to a power source e Start Pump in Water ONLY DO NOT run pump in air Rico Power CO2 may be utilized in either fresh water or salt water but not in foreign fluids flammable liquids or any chemical Warning This product may contain chemicals known to the state of California to cause cancer and or birth defects or other reproductive harm Wash your hand after hanaling this product 3 INSTALLATION 1 Choose a location for the CO2 reactor 2 Verify that the glass is clean 3 Secure to the aquarium using either the provided suction cup bracket or magnet mount
3. will be warranted for the remaining time of the original warranty period In no event shall any shipping charges be reimbursed In no event will TAAM be liable for any consequential or incidental damages including but not limited to lost sea life personal injury property damage equipment damage lost profits lost wages lost savings lost income etc arising out of the use of Rio Power CO2 Some states do not allow for the limitation or exclusion of liability for incidental or consequential damages so the above exclusion may not apply to you RETURNS Please contact our service center at 805 383 3566 ext 102 or fax 805 383 3565 to arrange repair and or replacement Please allow 4 6 weeks for all returns WARRANTY CARD Please go to our website to download Warranty Card http www riopump net Resources_folder Warranty html Fill out this warranty card and mail it with PROOF OF PURCHASE within 15 days of purchase ER EE aE I l i I Technological Aquatic Associated Manufacturing Fax 805 383 3565 Rio Production 85 1 Shuiyuan Rd Taipei Taiwan Fax 886 2 23688205 T WWW RIOPUMPS COM 2013 TAAM Specifications amp technical information may change without notice
4. Warning Buyer user assumes all responsibility for safety and proper use not in accordance with the directions and safety labels w o POWER CO gt agua pian svstews REACTOR amp SURFACE SKIMMER NOTE Package will only include either suction cup bracket or magnet mount It is your sole responsibilities to verify that the plug and the receptacle are clean and free of moisture and salt build up at all times The receptacle must be free of water salt calcium magnesium and dust Failure to do so can cause fire damage to property permanent damage to the product and personal injury GFCI not limited to loss of life ial Do not plug into extension cord power Strip A drip loop must be used when DRIP plugging all electrical aquarium i devices A drip loop is that part of the cord hanging below the receptacle The national code requires that a GFCI Ground fault circuit interrupter be used in the branch Circuit supplying all power to water pumps and electrical aquarium equipment If you do not have a GFCI have an electrician install one prior to operating any aquarium component Note It is important that the right pump and flow rate is being used for the given specific application Use the flow chart to determine the proper size pump and tubing to be used for given application FEATURE e Power Surface Skimmer e Produces Ultra Fine CO2 Bubbles e Carbon Dioxide Reaction Chamber e Connects Ea
5. en connecting the carbon dioxide source a Remove the air stopper b Connect a piece of silicone airline tubing to the carbon dioxide inlet c Install in an inline check valve d Connect piece of silicone airline tubing from the check valve to a bubble counter e From the bubble counter connect another piece of silicone airline tubing from the bubble counter to the carbon dioxide source 7 Plug pump directly to a GFCI outlet 8 Turn on carbon dioxide source NOTE Do not remove air stopper if using the unit as surface skimmer ONLY attached to the shaft Remove the impeller and the shaft clean all grim and debris Verify that the impeller spins easily on the shaft If there is any signs of damage or excess wear to the impeller and or the shaft replace complete impeller assembly 9 With a small brush clean the inside of the impeller well 10 Reassemble the unit 11 lmpeller may need to be replaced periodically to maintain a steady output flow Rio Power CO2 replacement parts are sold at your local pet dealer or call us TAAMe for more information for purchasing Rioe Power CO2 replacement parts 12 Do not tamper with or replace the power cord of this appliance If the cord is damaged the appliance should be discarded Surface Skimmer and Strainer They need to be clean regularly to insure proper water flow to the pump Remove the surface skimmer and strainer and clean well with water Remove all a
6. its will be required and attention from the user Carbon dioxide will drastically affect PH levels in the aquarium and if not properly monitored will cause loss of life in any aquatic environment WARNING amp SAFEGUARDS Read and follow the guidelines to ensure the proper use and application of this Rio Power COs Failure to follow these guidelines may result in damage to the aquatic environment and serious injury Operation and safety Precautions The National Code requires that a GFCI Ground Fault Circuit Interrupten be utilized in the branch circuit supplying all water pump and aquarium electrical equipment If you do not have a GFCI please see your local electrical supplier for this device Important Warning and Safeguards Do not operate pump with Rio Power CO2 without being fully submersed at all times Not doing so can cause permanent damage to the pump e Replace the impeller and or shaft if there is any excess signs of wear e Prior to maintenance on any electrical aquarium appliance or maintenance to the aquarium you must disconnect all electrical aquarium devices Routine maintenance is required to ensure the maximum performance and the longevity of Rio Power COzs See Maintenance Guidelines The national code requires all aquarium equipment to be plugged into a PART LIST Motor 2 Impeller 3 Impeller well cover 4 bushing 5 Shaft 6 CO2 reaction chamber 7 Foam pre filter 8
7. lgae build up and debris with a small brush CO2 source not included i Ya a w Bubble counter with check valve not included E ail GFCI amp CO ONLY ALUMINUM Drip CYLINDER loop Fie m fi l i a e ree LIMITED WARRANTY TAAM warrants that Rio Power COz is free from defects for a period of 6 months from the initial date of purchase shown on the original cash register receipt TAAM disclaims all other warranties of merchantability and or fitness for a particular purpose Although this limited warranty may give you specific rights you may have other rights that may vary from state to state This warranty is void if the failure of the pump or any part sealant or component there of is due to i misuse ii tampering iii negligence iv misapplication v abuse vi accident and or vii failure to properly a maintain 0 clean c keep pump fully submersed and or use the pump with a Ground Fault Circuit Interrupter GFC CONSUMER REMEDIES TAAM s entire liability and your sole and exclusive remedy shall be either repair or replacement of Rio Power CO2 only if you return the defective unit directly to TAAM with the original receipt in its original box along with seven dollars 7 00 for shipping and handling Do not send Rio Power CO2 by insured mail You may send your returns or replacements by UPS if requiring a signature upon arrival Any replaced unit
8. sily To Any CO2 Source e Injects CO2 Evenly And Efficiently e Clog Resistant Venturi e Simple And Easy Up e Patented AVAILABLE MODELS Aquarium UPC No Item No Description Size 0006760 Rio 90 Power CO2 F 35001 With Suction Cup Bracket lt 94 1455 4 Rio 90 Power CO2 60 cm F 5001M With Magnet Mount Rio 200 Power CO2 With Suction Cup Bracket gt 36 Rio 200 Power CO2 cm F 5002M With Magnet Mount Warnings Magnet mount Very strong magnet Not a toy Keep out of reach of children Failure to do so will cause serious injury and or permanent damage to your aquarium Keep out of reach of children Do to the strength of the magnets they will attract other metals or magnets with force When installing or handling magnets there must not be any other magnets or metals in close proximity to fhe magnet holders Failure to do so will cause serious injury Keep away from devices sensitive to magnetic fields such as pacemaker data carriers credit cards electronic equioment and medical devices Failing to do may result in permanent damage to such devices Never allow magnets to snap together e Always handle magnets one at a time Once separated keep a min of 12 apart e Hold magnets only by the sides Never get your fingers or hands between the contact services Caution When using carbon dioxide in any aquatic environment special equipment test k

Download Pdf Manuals

image

Related Search

Related Contents

  HDMI over IP EXTENDER Manual    

Copyright © All rights reserved.
Failed to retrieve file