1. User Manual version 2 0 0 ZVORK Volt SL1 User Manual Table of Contents oo baabeactcesebansceacsese 3 FOOL e L e E E A E E E ues E E A E 4 OR ee 4 FTA ISOS aa 4 MOU SION ee IS 5 PO SE IE ET NER A 5 Activating ASC A Sn 5 Copy Pasto OS ee N EA 5 MA Pee E A eee 6 SN ee 6 SO ne ee ee ree 6 1 MMM Pon e O rane sioner aseaseagnten theres 6 Alirio POR een 6 Back PANO PT O PO A IEEE N 8 Chimenea nn 8 E E ee A E ee 9 ale OD acess ater A A er EE 9 MIDI Implementation CAES pidan iio AE EEEE Erana 10 ZVORK Volt SL1 User Manual Introduction The Volt SL1 is a control voltage CV selector aimed at live performance and DJ ing With it you can switch or crossfade easily and in sync with the tempo between various values of control voltage signals ZVORK Volt SL1 User Manual Front Panel SZVORK t E On ce VOLTSLT Filter Freg Dec Phase FM Amount PWM Pate Transition i pama UA ate hn Duration f QUAS Ol 02 OF OF 05 06 OF 08 Paste Set Paste Ber ti Oe a AECE a ae i Fa A A w f Ar TT Hasal Su Hasal Soft ES ca On Off This switch is a quick way to silence all the control voltage outputs to zero value Controls Filter Fred Osc Phase FM Amount PWM Pate Ew OS 10 w 11E 15 _ ye A 9 Ol AAGA Up to 24 CV values with version 2 0 can be controlled by a SL1 unit For each control the value c
2. Paste of sets Configuring each control value for every set can be tiresome when a number of controls share the same value across sets To facilitate this you can copy control values from one set to another for every controls or for just a particular group of controls Start by selecting a set by pressing its set activation button This will be the source set Click on Copy Set Select the destination set by clicking its respective activation button Finally press Paste Set to copy all the control values or Paste Grp 1 Paste Grp 2 Paste Grp 3 or Paste Grp 4 to copy only the control values assigned to respectively the first group the default group second red third green and fourth blue ZVORK Volt SL1 User Manual Metering To the left of each set button is a small meter which displays the weight of the set in the current output When it is fully lit all the way up the set is the one applied to the output This is especially useful to visualize crossfades between sets Furthermore the instantaneous value of each 24 controls as they are sent to the CV values are represented graphically O1 of 03s OF O6 06 OF 08 So A Ai E ET 7 Noa El Y nn El T Wi b PRA S E RA i 0 0 Tl cis ME E e JL AAA AL ETE Lee 1520 Slave A Slave indicator is displayed at the bottom right of the set buttonst if your SL1 has its Set CV input on the back panel
3. als so as to control all SL1 s from one master unit This is particularly useful if you have exhausted all controls for your set or if you wish to have different transition settings for some of your controls When doing so the active set must be selected from the Master SL1 Once again the Slave LED indicator on the front panel lets you check if the device is a master or a slave You don t have to link the slave SL1 s directly to the master A slave unit can also be linked to another slave unit which in turn is connected to the master However chaining a great number of units may introduce some delay in the set activation on the last slaves ZVORK Volt SL1 User Manual SLAVE SL O ALLIE ALLIE DIET E sme rss Figure 1 One master SLI controlling one slave Gate Inputs You can also activate individually each set by plugging a Gate CV signal coming from an external source such as a Redrum or Matrix unit in the corresponding Gate input on the back panel In this case the SL1 is also considered to be a slave et its active set can no longer be applied from the front panel The slave LED will be lit if one of these Gate CV inputs is linked Figure 2 One SLI controled by external Gate C V si nals Gate Outputs Likewise you can also fetch an individual set activation signal thanks to the Gate CV outputs The value of the CV signal will be 1 while a set is activated and O when
4. an be set from 1 to 1 For clarity you can also edit the label above each control knob to keep track of what they are modifying Only the controls 1 to 15 are automatable and controls 16 to 24 have a pale green tint to help you remember this ZVORK Volt SL1 User Manual Control groups To help you keep track of the signification of each controls you can furthermore assign them to a color coded group There are 4 different group colors To change the group of a control simply press the button at the upper left of the control Knob until you have activated the correct group color Sets This section is where you can select the current set of control voltage values from 12 starting with version 1 1 possible sets identified by their letter A B C D E up to L Each set corresponds to one setting of the 24 control knobs of the SL1 A highlighted button corresponding to a set indicates the set currently modified by the control knobs You can name a set by double clicking the space above a set activation button an typing its name Validate by pressing the enter key Activating a set E G J L B To activate a set that is to have its control values output from the device see back panel section simply press the corresponding button Another mean of activating a set is through a MIDI keyboard When a Volt SL1 has the keyboard focus pressing a note activates a set Here is the layout for each octave DF HIKAC Copy
5. er Manual To do so start by switching to the transition curve edit Le el Ay page by clicking on the left or right arrow buttons at the bottom left of the control knobs panel E l The transition curve edit page has two sections To the left are displayed all the available transition curves from left to right then top to bottom linear the default accelerate decelerate accelerate then decelerate bounce in bounce out To the right are displayed for each control the current transition curves FT Click on the left side section on the transition curve Poren you would like to apply to a control This should HA highlight the button Then click on the corresponding control zone to the right to change the transition curve of a particular control You can change the curves of multiple controls with a single stroke by painting click and dragging across multiple control zones me Be GF 15 E F r gr i F 2 15000 22 34 7 F a HE d f d ZVORK Volt SL1 User Manual Back Panel CONTROL VOLTAGE SELECTOR Filter Freq fi leo Gates FEES A em Hara The back panel exposes the 72 output CV signals corresponding to the 24 controls For each control corresponds two CV outputs and one negated CV output It also exposes both input and output sockets for the activation of the set Chaining SL1 s You can link multiple SL1 s with the Set input output CV sign
6. linked to a CV signal In this case set activation is no longer possible from I the front panel buttons or from a MIDI keyboard as it is overridden by the CV signal You can still select your sets to modify the control knobs though Transitions Transition This section is where you define how the device should switch from one set to another as you activate them The default is to perform a brutal cut to the next set immediately after you activate it If you set the Duration parameter to anything but Off the device will gently crossfade between the previous set and the new set for the specified note duration If the Sync parameter is set to anything but Off the start of the crossfade or switch will occur at the next note of that particular length x se OF Op Duration SUAS GvOTAODess i au tet E E 6 So if you set Sync to 1 and Duration to 1 2 the crossfade between two sets will occur at the start of a measure and for half a measure Metering The countdown meter lets you see when the crossfade switch will start When all four dots are full the transition has started Transition curves By default and with previous versions of the SL1 transitions between two sets are done with a standard linear crossfade of each control values Starting with version 2 0 you can specify a non standard transition curve on a per control basis ZVORK Volt SL1 Us
7. this is not the case ZVORK Volt SL1 User Manual MIDI Implementation Chart MIDI Controller Parameter 4 Active Set 5 Transition duration 7 Transition sync 8 On Off 10 Set A Control 1 12 20 Set A Controls 2 to 10 21 30 Set B Controls 1 to 10 31 Set C Controls 1 33 42 Set C Controls 2 to 10 43 52 Set D Controls 1 to 10 53 62 Set E Controls 1 to 10 63 Set F Control 1 65 73 Set F Controls 2 to 10 74 78 Set A Controls 11 to 15 79 83 Set B Controls 11 to 15 84 88 Set C Controls 11 to 15 89 93 Set D Controls 11 to 15 94 95 Set E Controls 11 and 12 102 104 Set E Controls 13 to 15 105 109 Set F Controls 11 to 15 110 119 Set G Controls 1 to 10 128 132 Set G Controls 11 to 15 133 147 Set H Controls 1 to 15 148 162 Set I Controls 1 to 15 163 177 Set J Controls 1 to 15 178 192 Set K Controls 1 to 15 193 207 Set L Controls 1 to 15 10 ZVORK Volt SL1 User Manual More information at http www zvork fr audio 2013 15 Olivier Prat 11
Download Pdf Manuals
Related Search
Related Contents
V1_GYSPOT Evolution PTI Samsung CM1029A User Manual NX-ECC EtherCAT Coupler Unit Data Sheet GE JES0737 User's Manual Intel 4.0A User's Manual Liste de prix pour accessoires d`origine Mode d`emploi - Delta Import Kenmore 22.1 cu. ft. French-Door Bottom-Freezer Refrigerator w/Internal Dispenser - Stainless Steel Owner's Manual MODE D`EMPLOI USER MANUAL BONBONNE FILTRANTE Page 1 Page 2 vs_ 1550 kg A 2600 kg 50.0 m 40.0 m A @D _Q_ (D Copyright © All rights reserved.