Apricus Sentinel-Pro Controller Manual

image

Contents

1. Solar Collector H Auxiliary Heat Source Solar Storage Tank 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 15 Installation amp User Manual 6 3 Solar Collector System with Heat Extraction Essential Functions F3 amp F4 F12 amp F13 Required Sensors S1 S2 amp S3 Relay Setting R1 AUTO R2 OFF R3 AUTO Relay Clamps Sensor Clamps AC IN R1 R2 R3 S1 S2 S3 Comm LIEILT ILL Le r lt a Solar Collector Solar Storage Tank Heat Dissipator or Alternative Heat Usage 6 4 Solar Collector System with Heat Extraction amp Heat Boosting Essential Functions F3 amp F4 F10 amp F11 F12 amp F13 Required Sensors S1 S2 amp S3 Relay Setting R1 AUTO R2 AUTO R3 AUTO Relay Clamps Sensor Clamps ACIN R1 R2 R3 S1 S2 s3 Comm L Port Solar Collector ie i Auxilliary Heat Source Solar Storage Tank Heat Dissipator or Alternative Heat Usage 2007 Apricus Solar Co Ltd No responsibility will be acc
2. These values are negative indicating an inverse delta t value S1 lt S2 not a freezing temperature 3 2 Function Rules Certain rules are programmed into the controller to avoid conflict between functions F3 gt F4 The ON temperature must be greater than the OFF temperature F6 gt F9 The Collector Min Temp alarm must be lower than the Freeze Protection ON temp F13 gt F10 This prevents concurrent and continuous running of both R2 and R3 3 3 Detailed Function Explanation F1 Tank Maximum Temperature This function is used to prevent tank overheating and is commonly set close to the maximum temperature the tank can withstand or 80 C 177 F whichever is lower If this temperature is reached E1 will occur and shut off R1 solar pump preventing additional solar contribution This should only occur in extraordinary circumstances with the system designed to dissipate heat before this level is reached See F12 F13 in section 3 3 for information on the heat extraction function F2 Tank Minimum Temperature This function sets a minimum bottom of tank temperature with E2 occurring if the temperature drops below that level In most systems this function can be turned OFF 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 338 418
3. can be turned OFF by exceeding the upper or lower temperature range The display will show OFF instead of a temperature value Due to the relationship between different functions however the direction in which each function can be turned OFF varies See table in section 3 1 for details 5 6 2 Certain functions are interdependent and so turning one OFF will also turn the other OFF too To turn the functions both of them back on the one that was turned off must be activated by returning the temperature into the normal range The interdependent functions are F3 amp F4 F6 amp F7 F10 amp F11 F12 amp F13 F15 amp F16 5 6 3 F3 amp F4 are interdependent with F5 with S1 needing to first reach this temperature before F3 amp F4 can operate However if F5 is turned OFF F3 amp F4 will operate normally with restriction 5 6 4 To turn OFF freeze protection F6 amp F7 firstly raise F7 to gt 20 C 69 F then raise F6 to the upper limit to turn OFF To turn back ON decrease the F6 temperature setting 5 7 Changing Temperature Format The controller can operate using either centigrade or fahrenheit To change to C press and hold UP for 3 seconds To change to oF press and hold DOWN for 3 seconds Please note that this will also reset all functions to the system defaults 5 8 System Reset To reset to factory default settings select function F14 and press UP ON will be shown next to S1 and the system will be reset See
4. Heat Extraction System Essential Functions F12 amp F13 Required Sensors S3 Relay Setting R1 OFF R2 OFF R3 AUTO Relay Clamps Sensor Clamps l N otes AC IN R1 R2 R3 Comm If those functions requiring S1 amp S2 are ePELPELLE turned off they do not need to be installed S1 S2 S3 CODE e Solar Storage Tank Heat Dissipator or Alternative Heat Usage 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 18 Installation amp User Manual 7 Troubleshooting 7 1 Sensor Failure Sensor failures will be indicated by error reporting as follows E3 S2 failure bottom of tank E4 S3 failure top of tank E5 S1 failure collector Investigate the following Step 1 Ensure sensor cables are fully inserted into the cable clamps Step 2 Ensure extension cable connection is sound and dry waterproof Step 3 Ensure the cable is not damaged or has exposed wiring at any point If none of these problems are found please replace with new sensor 7 2 Inaccurate Temperature Readings Poor temperature accuracy is generally related to poor connections so firstly r
5. Apricus to organise an inspection of the system and if required a replacement controller 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 19 Installation amp User Manual 8 Maintenance The controller is not to be opened by the home owner under any circumstances If the controller ceases to function no response at all after a possible power surge the 8A fuse may have blown Please organise for a qualified electronics professional to replace the fuse with a new one 9 Warranty The Apricus Sentinel Pro controller Product is warranted against manufacturing defects for a period of 12 months from the date of installation as confirmed by the proof of purchase receipt and an installation record form that has been signed and dated by both the end user and installer Remedies for Breach of Warranty A Customer will notify the Apricus dealer or distributor from whom it purchased a Product promptly in writing of any alleged defect in that Product The dealer or distributor will investigate the defect to determine if it is covered by the warranty and report its findings to the Apricus distributor that sold the Product to the dealer in the case of
6. Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 4 Installation amp User Manual Technical Data Inputs 3 temperature sensors NTC 100K gt Controller supplied standard with 2 x 2m 78 low temp sensor Max 1104 C 230 F 1x 2m 78 high temp sensor Max 200 C 395 F Outputs 3 relays 4A each Total max 6A Power Supply 110 240V AC 50 60Hz Power Consumption 4 Watts Fuse Rating 8A Error Reporting LCD display of each error amp 10 sec audible alarm Casing ABS Plastic Display Liquid Crystal Display LCD gt 24 hour format time display Individual display of all errors Individual display of all three sensor temperatures C or F gt Individual display of relay status including time setting Power status Operation 7 push buttons gt Power Time Relay Function Up Down Set Mounting 2 x rear slots for wall mounting on screw head Dimensions amp Weight gt LxWxH 200x210x39mm 8 6x8 2x1 5 gt Gross Weight 600g 1 32Ib not includind sensors Environmental Conditions 0 40 C 32 104 F Indoor use only Communication Port For connection of optional data reading equipment Electrostatic discharge can cause Warning Parts are high energy damage of electronic components voltage energized 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or tec
7. circulates when the collector temperature S1 is LOWER than the bottom of tank S2 level This heat dissipation function can be enhanced by using the heat extraction function F12 F13 to circulate hot water from the top of the tank to the bottom of the tank thus mixing the tank water and ensuring the whole tank is cooled to the target level and not just the bottom of the tank below the level that the solar water is returned to 4 Error Reporting The following errors are reported both on the LCD display and by a 10sec audible alarm E1 Tank Overheat R1 turned OFF to prevent additional solar input E2 Tank Low Temp Alarm E3 S2 Failure Alarm poor connection damaged cable or faulty sensor E4 S3 Failure Alarm poor connection damaged cable or faulty sensor E5 S1 Failure Alarm poor connection damaged cable or faulty sensor E6 Collector Overheat Alarm E7 Collector Low Temp Alarm 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 12 Installation amp User Manual 5 Settings 5 1 Control Buttons Saree E The various functions of the controller are RAs Sentinel Pro ettin Multi Function Delta T Solar Controller accessed th
8. 9 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 10 Installation amp User Manual F3 F4 Delta T ON amp OFF This pair of functions form the delta t settings which control the solar circulation pump R1 The default settings are 8 C 14 F ON F3 and 2 C F OFF F4 circulating the pump when the solar collector is HOTTER than the S2 sensor which generally measures the bottom of the solar tank F5 Collector Start up Temperature In order to regulate the operation of the solar circulation pump R1 controlled by functions F3 amp F4 F5 sets a minimum operating temperature the solar collector must first reach The default setting is 30 C 86 F If this setting is turned OFF pump circulation F3 F4 will operate normally but without a minimum temperature requirement F6 F7 Freeze Protection In areas with only mild winter temperatures a plain water direct flow system can be used instead of a closed loop glycol water system Freeze protection is achieved by circulating water from the bottom of the tank thus warming the collector This will occur periodically throughout the night F6 sets the ON temp close to freezing and F7 the OFF temperature The F7 value should always be less than the incoming cold water supply temperature otherwise the pump could run continually For closed loop systems this feature is normally turned OFF in particular because the accuracy of sensor S1 is poore
9. CUS Apricus Sentinel Pro Multi Function Solar Controller Sentinel Pro Multi Function Delta T Solar Controller r Power J u s SYT RI s2 4ST Ro 3 BOE ON OFF Installation amp User Manual Edition 1 3 June 2007 Please read this manual carefully to ensure safe and reliable operation of the controller Apricus Sentinel Pro Solar Controller Page 2 Installation amp User Manual Contents Page Introduction 3 Technical Data 4 Safety Precautions 5 1 Installation 1 1 Mounting 6 1 2 Electrical Connection 6 1 3 Sensor Connection 7 1 4 Communication Port 7 2 LCD Display 8 3 Function Overview 3 1 Function Table 9 3 2 Function Rules 9 3 3 Detailed Function Explanation 9 4 Error Reporting 11 5 Settings 5 1 Control Buttons 12 5 2 Setting Time 12 5 3 Programming Relay Times 12 5 4 Controlling Relays ON OFF AUTO 12 5 5 Setting Temperature Ranges 13 5 6 Turning Functions OFF 13 5 7 Changing Temperature Format C or F 13 5 8 System Default Settings 13 6 System Diagrams 6 1 Basics Solar Collector System 14 6 2 Solar Collector System with Heat Boosting 14 6 3 Solar Collector System with Heat Extraction 15 6 4 Solar Collector System with Heat Boosting amp Extraction 15 6 5 Twin Tank Solar Collector System forced circulation 16 6 7 Heat Boosting System 16 6 8 Heat Extraction System 17 7 Troubleshooting 7 1 Sensor Failures Errors E3 E4 amp E5 18 7 2 Inaccurate Sensor R
10. Settings This function resets the system to the default settings See 3 1 for default settings 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 11 Installation amp User Manual F15 F16 Tank Cooling During periods when no water is being used home owner is on holiday or just during periods of high solar radiation the solar input may cause the storage tank temperature to increase eventually causing an E1 Max Tank Temp error if F1 is activated and collector stagnation or hot water dumping from the temperature relief valve This functions aims to dissipate excess heat in a safe and passive manner via heat losses through the circulation loop at night F15 sets a bottom of tank temperature at which the tank cooling function will initiate A suitable range is 45 55 C 114 132 F If hot water is used by the home owner cold water will have entered the bottom of the tank dropping the temperature and thus the tank cooling function will not turn on F16 sets the delta t at which the solar pump R1 will operate Please note that this is a negative delta t value the opposite of the normal F3 F4 function that operates during the day The pump only
11. a dealer and to Apricus in all cases Based upon such review Apricus will have the right in its sole and absolute discretion to determine whether or not the defect violates the applicable warranty CUSTOMER S SOLE AND EXCLUSIVE REMEDY WITH RESPECT TO ANY BREACH OF ANY WARRANTY AS DETERMINED BY APRICUS IN ITS SOLE DISCRETION BY A PRODUCT DURING THE APPLICABLE WARRANTY PERIOD WILL BE THE REPAIR OR REPLACEMENT OF THE PRODUCT BY A DESIGNEE OF APRICUS OR IN APRICUS S SOLE DISCRETION A REFUND OF THE PURCHASE PRICE OF THE PRODUCT TO THE CUSTOMER These remedies will be provided within a reasonable amount of time and without additional charge Apricus will not be responsible for any costs or expenses associated with the investigation or analysis of an alleged defect or any repair charges for service to the Products that is not covered hereby Apricus s total liability to Customer with respect to any Product shall be limited to Customer s purchase price for the Product APRICUS WILL NOT BE LIABLE TO ANY PARTY INCLUDING THE CUSTOMER FOR ANY CONSEQUENTIAL EXEMPLARY INCIDENTAL INDIRECT LIQUIDATED PUNITIVE SPECIAL SPECULATIVE OR OTHER SIMILAR DAMAGES INCLUDING WITHOUT LIMITATION ANY DAMAGES TO PROPERTY OR COST OF REPLACEMENT GOODS RESULTING FROM ANY BREACH OF WARRANTY BY A PRODUCT OR ANY PRODUCT DEFECT This paragraph sets forth a Customer s sole and exclusive remedy with respect to any Product and a Customer shall not have any other remedy
12. d OFF to the same time 5 4 Controlling Relays ON OFF AUTO 5 4 1 Each relay can be set to an ON OFF or AUTO status which overrides all other system settings including relay time settings see 5 3 AUTO will allow normal operation of the time and function settings Step 1 Press RELAY the black dot next to R1 will flash and ON OFF or AUTO will be displayed next to S1 in the temperature display area Step 2 Press UP or DOWN to cycle through the three settings Step 3 Press SET to confirm 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 338 4189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 13 Installation amp User Manual 5 5 Setting Temperature Ranges Each of the function settings with the exception of F14 reset has a temperature setting Step 1 Press PROG to enter the function menu starting with F1 Press either PROG or SET to cycle through each function setting To return to normal operating mode cycle through all functions or leave the controller for 10 seconds and it will return automatically Step 2 Press UP or DOWN to adjust temperature setting Step 3 Press SET to confirm changes 5 6 Turning Functions OFF 5 6 1 Any function with the exception of F14 reset
13. eadings 18 7 3 Miscellaneous Problems 18 8 Maintenance 19 9 Warranty 19 10 Disclaimer 19 11 Installation Record Form 20 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 3 Installation amp User Manual Introduction The Sentinel Pro solar controller is a multi function device used to monitor and control thermal solar systems With comprehensive control over temperature ranges and the operation of each relay the Sentinel Pro is suitable for both domestic and commercial applications An LCD display provides clear feedback on the status of the system Key Features V Clear LCD display of all temperatures relay operation and errors V Adjustable temperature ranges for all functions V ON OFF AUTO control of each relay vV Daily time control of each relay V Auto recover after power cutout full memory of system settings V Easy to mount casing with punch out panels for conduit entry V High accuracy NTC 100K temperature sensors 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061
14. epted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 16 Installation amp User Manual 6 5 Twin Tank Solar Collector System Forced Circulation Essential Functions F3 amp F4 F12 amp F13 Required Sensors S1 S2 amp S3 Relay Setting R1 AUTO R2 OFF R3 AUTO l Relay Clamps Sensor Clamps N AC IN R1 R2 R3 S1 Comm cn E cn E Port Solar Collector Solar Storage Tank Main Electric Gas Boosted Tank 6 6 Heat Boosting System Essential Functions F10 amp F11 Required Sensors S3 Relay Setting R1 OFF R2 AUTO R3 OFF Relay Clamps Sensor Clamps N otes ACIN R2 s1 If those functions requiring S1 amp S2 are ong Bog non 3 COCO nn bal turned off they do not need to be installed Auxilliary Heat Source Hot Water Storage Tank 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 338 4189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 17 Installation amp User Manual 6 6
15. hnical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 5 Installation amp User Manual Safety Precautions Electrostatic Discharge Care should be taken to avoid exposure of the controller to electrostatic discharges as this could damage circuity components High Voltage The controller is high voltage energized and therefore MUST have power supply disconnected when the bottom cover is opened and when servicing consumers connected to the relays Prevent Water Ingress The controller is NOT water proof and should only be installed with full protection from water Extremely humid environments should also be avoided Avoid Direct Sunshine The LCD display can be damaged or temporarily turn black if exposed to direct strong sunlight In addition the casing will absorb heat from sunlight which may cause the interior to exceed maximum temperature limits Authorized Persons Any work involving supply of high voltage power to the controller may require authorised electrical professionals Always adhere to local regulations regarding electrical safety Lightning Protection Suitable lightning protection should be incorporated into the electrical system to avoid damage to the controller Cable Glands Ensure all cables running into the co
16. ng on region Sensors are not negative and positive and so can the wires can be inserted into either hole of the cable block Sensors can be extended up to 30m using 18 gauge 0 8mm electrical wire Longer lengths may reduce the accuracy of the temperature reading Sensor connection to controller is as follows 1 Solar collector HIGH TEMP S2 Bottom of tank LOW TEMP S3 Top of Tank LOW TEMP Coat sensors with a thin layer of silicone heat transfer paste and ensure tight metal contact with the point of temperature reading Protect sensors from water ingress as sensors are not suitable for long term immersion in water For some functions not all sensors are required If one or more sensors are not installed the relevant error will be shown on the display and a 10 second alarm will sound on initial power on The system will operate for those function that have the necessary sensor s installed 1 4 Communication Port see Figure 3 A communication port is provided to allow connection of accessories such as a data logger or external display that may be offered by Apricus 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 338 4189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Contr
17. nsumer Power Supply Relays 3 relays each rated to 4A 100V 440W 220V 880W Relays provide power supply to pumps or solenoid valves see section 3 for more information Power cable must be able to safely supply 6A Relay Clamps Sensor Clamps AC IN Comm R1 R2 R3 S1 S2 S3 LT JLLILEL Le 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 Figure 3 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 7 Installation amp User Manual 1 2 3 Cable Insertion into Cable Blocks Step 1 Strip the wire back expose about 5mm 0 2 of wire Step 2 Push back the green tab with your finger a key or a screwdriver and insert the cable to the full depth Step 3 Ensure the cable is firmly in place and there is no exposed wire visible 1 2 4 Cable Gauge Cable supplying power to controller and relays should be 12 gauge 3mm electrical wire Extension cable for the sensors should be 18 gauge 0 8mm electrical wire Figure 4 1 3 Sensor Connections see Figure 3 Each controller is supplied with one high temp sensor and two low temp sensors The high temp sensor cable is either a twin twisted cable or is a different color to the other two low temp cables dependi
18. ntroller are secured firmly in place by the supplied cable glands or run within conduit Conduit Where possible use PVC or metal conduit to run cables into the controller Conduit may enter the controller from the sides or rear through the punch out panels Correct Settings Incorrect settings can cause damage to the thermal solar system Please contact Apricus if you are unsure of what settings to use 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 6 Installation amp User Manual 1 Installation Rear mounting slots 8 Punch out panels for m rear cable entry han f Q Cable Glands Punch out panels left amp right for Bottom punch out panels for cable Larger diameter for side conduit entry gland usage power cable entry Figure 1 1 1 Mounting The controller can be mounted on a wall or plate using two flat head screws Figure 2 shows mounting slot spacing and hole dimensions 80mm 3 15 0 47 Figure 2 0 25 1 2 Electrical Connections 1 2 1 Power Supply 110 240V AC 50 60Hz Power supply must include an earth Power cable must be able to safely supply 6A 1 2 2 Co
19. oller Page 8 Installation amp User Manual 2 LCD Display The LCD display is divided into 5 main areas displaying time errors relay status temperatures and power on status Errors E1 O 24 hour time display Pot J ar Power E30 N l E E40 Relay Status S1 SY L E50 R1 s2 Yor E6O R20 rien E7O R3O S3 DuL Figure 5 Time Display Shows the current time 24 hour format Show the ON OFF time setting when programming relay time see also section 5 3 Error Status A black dot indicates an error is present see also section 4 Relay Status A black dot indicates the relay is ON The clock icon indicates that a time range has be set Temperature Display Shows the current temperature of each sensor in C or F Shows the temperature setting when programming each function The S1 temperature area will display the words ON or OFF when completing relay time programming Power A black dots indicates power ON 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 338 4189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 9 Installation amp User Manual 3 Functions Overview 3 1 Function Table The c
20. ontroller has a number of features which are programmed through a set of function settings numbered F1 F2 F 16 The following table shows each function setting the function that it controls how to turn it off and the available temperature ranges Values in brackets are the default setting OFF indicates the function is disabled by default Tank Max Temp Setting Will turn R1 OFF 40 99 80 104 210 176 Tank Min Temp Setting s2 u 206 36 105 41 Delta T ON Temp Setting S1 amp S2 2 30 8 4 54 14 Delta T OFF Temp Setting S1 amp S2 1 29 2 2 52 4 Collector Start up Temp Setting 10 60 30 50 140 86 Collector Freeze Protection ON Temp Setting 20 20 2 4 68 36 Collector Freeze Protection OFF Temp Setting 10 40 7 14 105 50 Collector Max Temp Alarm Temp Setting s4 t 60 200 140 140 392 284 Collector Min Temp Alarm Temp Setting ost 20710 2 4 50 28 Heat Boost ON Temp Setting s3 R2 30 70 50 86 158 122 Heat Boost OFF Temp Setting 40 80 OFF 104 176 OFF Extract Heat ON Temp Setting s3 R3 t 25 99 0FF 77 210 OFF ss Extract Heat OFF Temp Setting Ss eo ft 20 90 OFF 68 194 OFF EN Tank Cooling ON Temp Setting Fe 20 80 OFF 68 175 OFF F16 Tank Cooling Delta T setting negative values S1 amp S2 R1 tt 10 2 OFF 18 4 OFF Indicates the direction in which the temperature should be adjusted to turn the function OFF see also 5 6
21. or remedies at law in equity or otherwise 10 Disclaimer Apricus has made every effort to ensure the completeness of the information in this document however the accuracy of such information and drawings is not guaranteed The system drawings and system configuration information are examples only Apricus requires that only experienced and qualified persons are permitted to install this controller Apricus will not be held liable for any damage related to false misleading or incorrect information in this document Apricus may make changes to the controller from time to time and therefore specifications functions and operational procedures of the controller may differ from the contents of this document 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 20 Installation amp User Manual 11 Installation Record Form End User Instructions After installation the Installer should complete this form and leave it with you for your records Please keep in a safe place as this provides proof of installation date and who completed the installation If you installed this controller yourself not recommended please fax or email to Apricus Ins
22. r below freezing point F8 Collector Maximum Temperature This function is used for error reporting E6 indicating that the collector has reached elevated temperatures possibly indicating system malfunction such as pump failure F9 Collector Minimum Temperature Should the freeze protection function fail to maintain the collector temperature at safe level this setting will initiate error reporting E7 F10 F11 Heat Boosting Temperature Systems using an external heating source such as a gas booster oil boiler or pellet boiler can use this function to operate a circulation pump R2 when the top of tank temperature S3 drops below a minimum threshold Please note that R2 cannot directly run an electric element but can run a high amperage electronic switch that supplies power to the element F12 F13 Excess Heat Temperature For systems designs with significant solar input heat may be used for space heating hot tub heating or similar as well as providing hot water This function turns on R3 when S3 temperature exceeds a threshold If there is no secondary use for the excess heat a heat dissipation loop may be used to remove the heat If used for heat dissipation this function is ideally used in combination with Tank Cooling F15 F 16 This function may also be used in twin tank system to move hot water from the top of the solar tank to the second tank thus increasing the total storage capacity heated by solar F14 System Default
23. rough the seven buttons on the front panel Throughout this manual they are referred to as ON OFF TIME Time Button PROG Program Button A SET 4 ON OFF Controller On Off Button C O D RELAY Relay Button UP Adjust Up Button www apricus com DOWN Adjust Down Button Figure 6 5 2 Setting Time 5 2 1 Setting the clock is required if relay time ranges are to be used see 5 3 To set the clock follow these simple steps Step 1 Hold down TIME for 3 seconds until the hour digits start flashing Step 2 Press UP or DOWN to adjust hours 24 hr format Press SET to confirm Step 3 Press UP or DOWN to adjust minutes Press SET to confirm 5 2 2 The controller is fitted with a battery to maintain time and all function settings even after a power failure disconnect 5 3 Programming Relay Times 5 3 1 Each relay can have a daily ON amp OFF time period set Only during the ON period will the relay be activated enabling the normal function settings to take effect Step 1 Press TIME the clock symbol next to R1 will flash Step 2 Set the ON time for the relay as per the instructions for setting the clock time in 5 2 Step 3 Set the OFF time press SET to finish The controller will return to normal operating mode Step 4 To set R2 press TIME twice to set R3 press TIME three times 5 3 2 Once a time range has been set the clock symbol will be displayed next to the relay icon To remove the time setting set both ON an
24. table in section 3 1 for default settings 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 338 4189 Web www apricus com Email service apricus com Apricus Sentinel Pro Solar Controller Page 14 Installation amp User Manual 6 System Diagrams 6 1 Basic Solar Collector System Essential Functions F3 amp F4 Required Sensors S1 S2 amp S3 Relay Setting R1 AUTO R2 OFF R3 OFF Relay Clamps Sensor Clamps Notes ACIN RI R2 R3 s1 s3 Comm If those functions requiring S3 are turned off Pon S3 does not need to be installed HQE LIN JE HQE JHE yt ates If the system is a closed loop with an external heat exchanger R1 should be wired to supply power to both pumps one for the solar loop one on the fresh water tank side Ensure that the total electrical load of the two pumps does not exceed 4A Solar Collector Solar Storage Tank 6 2 Solar Collector System with Heat Boosting Essential Functions F3 amp F4 F10 amp F11 Required Sensors S1 S2 amp S3 Relay Setting R1 AUTO R2 AUTO R3 OFF l Relay Clamps Sensor Clamps AC IN R1 R2 R3 S1 82 s3 Comm L Ne L N oe IE Port roui M
25. tallation Date Installers Name End User s Name Controller Serial Code Controller Version City State amp Country Signed by End User Date Signed by Installer Date Thank you for choosing Apricus 2007 Apricus Solar Co Ltd No responsibility will be accepted for any mistakes or technical changes AS 1 2 10 1 Rev 16 7 07 402 Building 8 East Pukou New amp High Tech Development Zone Nanjing China 210061 Ph 86 25 58649133 eFax 1 206 3384189 Web www apricus com Email service apricus com
26. un through the steps outlined in 7 1 If the problem is not solved please investigate the following Step 1 Ensure the sensor probe is inserted fully into the port with tight metal to metal contact The sensor should be coated with silicone heat transfer paste to ensure optimal heat transfer Step 2 Check the sensor for damage cracking etc If damaged replace Step 3 Test the sensor in a cup of hot water together with another sensor or thermometer A variance of several degrees is common particularly for the high temperature sensor Step 4 Change the position of the sensor on the connection block swap with another sensor and see if the temperature reading is the same If a strange reading is still provided by the sensor then it may be faulty and should be replaced If the reading is normal but the other sensor now provides an incorrect reading it may be a problem with the connection block requiring replacement of the controller 7 2 Miscellaneous Problems Problems related to strange operation of functions incorrect cycling of the pump or continuous error reporting may simply be due to incorrect function settings Step 1 Use F14 to reset the system to default settings then re configure each setting as required Step 2 Turn OFF any relays and functions that are not required Step 3 Ensure sensors and consumers are connected properly Step 4 Thoroughly read this instruction manual again If the problem persists please contact

Download Pdf Manuals

image

Related Search

Related Contents

ナースのための人工呼吸器  ロロFFELE蔦=EE團@ 自転車 組立説明書B  HI 98509 • HI 98510  Samsung Galaxy Xcover 2 Kasutusjuhend  Dance Walker Andador de la Danza  - D`accéder au détail des garanties souscrites  USER MANUAL - Future Security Systems Ltd  取扱説明書(PDF)  horen Ventilated Caging - Lithgow Laboratory Services  Martillo combinado TE 80-ATC/ TE 70  