1. e Do not short the two case sides of a MicroCure together Doing so will reset the unit and clear any stored data e Do not allow MicroCure radiometers to touch each other Data loss or corruption may occur e Do not mark or label the MicroCure radiometer case Operation Operation of the MicroCure and MicroCure Plus is the same except that the MicroCure Plus is also capable of measuring peak irradiance AN WARNINGI Risk of exposure to ultraviolet light Although this product is not a source of UV light it is used in a UV environment Refer to the UV source s documentation for recommended protective measures 1 Insert the MicroCure into the slot in the upper left side of the DataReader 2 Press the RESET button to turn on the unit The DataReader will briefly display the software version Px xx rxx where xx is the number of unit resets then 0 00 to indicate that the unit is ready to take a reading 3 Place the MicroCure into the UV process with the optics aperture facing the direction of the UV source NOTE The MicroCure must be exposed to UV light within four minutes after being reset Otherwise it will go into standby The DataReader automatically shuts down after thirty seconds of inactivity 4 Remove the MicroCure from the UV environment and place it back into the slot in the DataReader 5 Press the SELECT button For a standard MicroCure radiometer the DataReader will display the UV dosage in Joul
2. A 320 390nm Sample Rate 2000 samples per second Total Energy 0 to 9999 Joules cm Display flashes if over ranged Energy Accuracy 7 typical 25 C 0 2 per C over operating range Peak Irradiance MicroCure Plus only Low Power 100mW cm to 2W cm High Power 500mW cm to 10W cm Display flashes if over ranged Peak Irradiance Accuracy 7 typical 25 C 0 2 per C over operating range Spatial Response Approximately cosine Operating Temperature Range 15 70 C internal Time out Period 4 minutes nominal after last UV exposure Batteries Permanent lithium cell Battery Life 200 readings with typical use or 1 year Dimensions 1 30 long x 1 0 wide x 0 25 high 33 0mm x 25 4mm x 6 4mm Weight 0 33 oz 9 4 grams Materials Plated aluminum nylon DataReader User Interface Push button switches allow user to display data or reset the unit Display 4 digit liquid crystal display Dimensions 5 75 long x 4 38 wide x 1 2 high 139 7mm x 108mm x 25 4mm Weight 11 75 oz 333 11 grams Operating Temperature Range 0 70 C Timeout 30 seconds Battery 9Volt Lithium 36 000 readings or 5 years Alkaline battery life not specified Materials Steel nylon polycarbonate Specifications subject to change Table 2 MicroCure and DataReader Specifications Case Dimensions The physical dimensions of the MicroCure radio
3. CON TROL CURE MicroCure And MicroCure Plus Instruction Manual on MICROCURE DATA READER MicroCure Radiometers and DataReader MicroCure And MicroCure Plus Instruction Manual cr Application of Council Directive 89 336 EEC Electromagnetic Compatibility Standards to which conformity is declared EN55011 1991 and EN50082 1 1992 Introduction The MicroCure and MicroCure Plus radiometers are electro optical devices that measure the ultraviolet light that a work piece receives in a UV curing system The MicroCure measures UV dosage while the MicroCure Plus measures dosage and peak intensity Both units are spectrally responsive to the UVA range 320 390nm Their compact size makes it possible to get measurements in curing applications that were previously inaccessible to radiometers label bottle or CD printing container decorating and many web press applications The MicroCure is inserted into a process before the UV source and then extracted immediately afterward prior to reaching areas such as print stations or die cutters Figure 1 MicroCure Handling Precautions Due to the radiometer s case configuration and the applications for which it was designed the following precautions should be observed to ensure the radiometer s performance e Do not let the MicroCure radiometers travel through print stations die cutters pinch rollers or other processes which may damage either the radiometers or your equipment
4. This warranty is exclusive of any and all other warranties expressed or implied This includes merchantability and fitness as well as any and all other obligations or liabilities of UV Process Supply We shall not be responsible for consequential damages resulting from malfunctions of the goods described in this manual This warranty shall not apply to any item not manufactured by UV Process Supply Calibration and Repair Warranty The warranty for repair service and periodic calibration is as stated previously for new units except that the warranty period is ninety 90 days Following are the instructions for warranty returns Warrantv Returns When returning the equipment under warranty include any accessories sent with the equipment so that UV Process Supply can verify correct operation of these accessories Please return the equipment in the original or equivalent packaging If the original packaging is not used you will be responsible for damage incurred from inadequate packaging The purchaser is responsible for insuring the unit during transportation to UV Process Supply Equipment repaired under warranty will be returned to the user with no charge for the repair or shipping UV Process Supply will notify you of repairs not covered by warranty and their cost prior to performing any work on the equipment UV Process Supply reserves the right to make changes in design at any time without incurring any obligation to install th
5. cate a low battery condition by scrolling LO across its display Remove the two screws from the plate on the left side of the DataReader Remove the battery and replace it with a new 9 Volt lithium or alkaline battery Reinstall the access plate and screws Standard Equipment The MicroCure and MicroCure Plus basic sets consist of 1 MicroCure or MicroCure Plus radiometer 1 DataReader display unit 1 Carrying Case 1 User s Manual Optional Accessories Replacements and spares of any item listed above may be ordered directly from EIT Inc or any of its authorized representatives A Web Accessory Kit shown in Figure 2 is available for placing and removing MicroCures in UV systems Figure 2 WAK 1 Web Accessory Kit Ordering Information The following is a list of the MicroCure family of products and their EIT model numbers Please use these numbers when placing your order MicroCure Radiometer High Power MC 10 MicroCure Radiometer Low Power MC 2 MicroCure Plus Radiometer High Power MCP 10 MicroCure Plus Radiometer Low Power MCP 2 DataReader MCR 2000 Carrying Case CCl DataReader Battery DRB Web Accessory Kit WAK Table 1 Model Number List Specifications MicroCure and MicroCure Plus Radiometers Power Range Low Power 2 100mW cm to 2W cm High Power 10 500mW cm to 10W cm Display flashes if over ranged Spectral Response UV
6. e same on units previously purchased Ship the unit freight prepaid to UV Process Supply 1229 W Cortland St Chicago IL 60614 A Return Material Authorization is required when shipping the unit back for warranty service Include your company name address telephone number fax number and or e mail address on your shipping documents You will be advised of the RMA number and expected turnaround time after calling UV Process Supply at 773 248 0099 Non warranty Returns Repair service on calibrated units includes calibration after the repairs are effected Please return the equipment in the original or equivalent packaging If the original packaging is not used you will be responsible for damage incurred from inadequate packaging The customer is responsible for insuring the unit during transportation to UV Process Supply Ship the unit freight prepaid to UV Process Supply 1229 W Cortland St Chicago IL 60614 A Return Material Authorization is required when shipping the unit back for calibration or repair Include your company name address telephone number fax number and or e mail address on your shipping documents You will be advised of the RMA number and expected turnaround time after calling UV Process Supply at 773 248 0099
7. es per square centimeter J cm For a MicroCure Plus radiometer the DataReader will display either the dosage or the intensity in W cm Press and hold the SELECT button to toggle between dosage and intensity 6 Press the RESET button when the reading is displayed to clear the current reading and set the MicroCure for its next reading Error Messages The DataReader displays error messages if there is a problem with it or the MicroCure If is displayed communication between the MicroCure and the DataReader has failed Re insert the MicroCure in the DataReader and try again If LO BATT is displayed the MicroCure s battery is low If this occurs within its 200 reading 1 year limitation the unit or battery may be defective Contact EIT for assistance When the DataReader s battery is low it will scroll the word LO ten times and then shut down Refer to the Maintenance section of this manual for replacement instructions If the DataReader displays a numeric error code contact EIT for assistance Applications Establishing A Cure Or Process Window A cure or process window is a set of parameters that defines equipment settings and run conditions to ensure proper curing A cure window gives the user an edge in troubleshooting deficiencies in a UV process Ideally tests are run for every combination of coating and substrate so that a history can be obtained This history helps establish baseline paramete
8. he MicroCure s sample rate of 2000 samples per second produces accurate readings at high system speeds Ideally a MicroCure is jogged through a web process to make its application and removal from the process easier Since dosage readings are directly proportional to exposure time a reading for a high speed system can be derived from a reading taken at a slower speed For example if the system speed is usually 600 feet per minute jog the system down to 60 fpm and take a dosage reading This reading represents the UV dosage of the system at 1 10th the speed To translate this to 600 fpm simply divide the dosage reading by 10 NOTE Irradiance readings with the MicroCure Plus should be consistent and are not dependent on speed The MicroCure Plus should register similar irradiance readings when consistent data collection techniques are followed Maintenance MicroCure Radiometer Clean the radiometer s aperture with a cotton swab and isopropyl alcohol Use isopropyl alcohol and a soft cloth to clean the case of the radiometer Do not open the radiometer s case There are no user serviceable parts inside the unit The MicroCure radiometer is given a one time calibration before it is shipped from EIT It is specified to take 200 readings or last for one year Once the unit meets one of these conditions it must be replaced DataReader The only maintenance required for the DataReader is occasional battery replacement The DataReader will indi
9. meter and the DataReader are shown in Figure 3 below 4 38 foe Ae Figure 3 MicroCure and DataReader Case Dimensions Warranty and Returns Contacting EIT UV Process Supply can be contacted for customer service support via the following means UV Process Supply 1229 W Cortland St Chicago IL 60614 Voice 773 248 0099 Fax 773 880 6647 E mail info uvps com Internet www uvprocess com New Equipment Warranty UV Process Supply warrants that all goods described in this manual except consumables shall be free from defects in material and workmanship for a period of six months after delivery to the buyer At its discretion UV Process Supply will replace or repair the defective goods We will provide all repair support at no cost to the buyer only if the defective goods are returned freight prepaid to us during the warranty period UV Process Supply shall be relieved of all liabilities under this warranty if 1 Upon inspection the goods show evidence of becoming defective due to abuse mishandling accident alteration negligence lack of routine maintenance or other causes beyond our control 2 The goods have been repaired altered or modified by other than UV Process Supply authorized personnel 3 The buyer does not return the defective goods freight prepaid to UV Process Supply within the applicable warranty period There are no warranties that extend beyond the description on the face hereof
10. rs for various chemical material combinations and provides important information for process control The operator can compare a current measurement to the cure window and adjust his process to get the desired curing results The Process Value The process value is often defined as the total dosage or total energy produced by the system It is the mathematical integration of lamp intensity over time The MicroCures derive this value by measuring instantaneous lamp intensities during the run and then summing them together The process value must be maintained to get complete UV curing every time Bottle Printing Can Decorating CD Printing The small size of the MicroCure radiometer provides extra flexibility to read UV light in a variety of ways that were previously impossible They can be placed inside cans tubes or bottles put into CD nests or mounted on odd shaped items which require UV curing Web Presses The MicroCure is able to travel vertically and between idler rollers This makes it ideal for narrow and wide web applications Mounting the MicroCure to a web can be as simple as using double sided tape to attach it and a shunt or arm to remove it A set of devices designed specifically for the insertion and removal of MicroCures is available from EIT and is described later under Optional Accessories Caution should always be exercised when inserting or removing MicroCures from web applications Hish Speed Applications T