1. this indicates that the inverter is in power saving sleep mode and is idling at no load Power saving sleep mode disabled 9 2 6 1 9 2 6 2 9 2 6 3 The front plate has a green led marked power saving for indication of enabled state of power save sleep mode here in after referred to as the green led The power saving sleep mode is disabled when the green led marked power saving is off In this mode the output power is always available Following indications will be observed when the inverter is powered on and subsequently loaded and unloaded when power saving sleep mode is in disabled condition the initial condition is that the inverter is switched off and all loads are disconnected 9 2 6 3 1 Switch on the inverter There will be 2 beeps and green led will start flashing with a flashing sequence of flash flash flash After about 3 seconds there will be 1 beep and the green led will stop flashing and switch off Output power will be available after about 15 to 18 sec from the time the green led switches off The output power will be always available even in no load idling condition The green led will be off all the time 31 Sinengex 9 2 7 Switching between enabled and disabled states of power saving sleep mode 9 2 7 1 Switching between enabled and disabled states of power saving sleep mode can be done with the help of the power on off switch on the front plate of the
2. Sinergex PureSine 1500 N LM ser s Manua Sinergex Technologies L L C USA Website www sinergex com Email office sinergex com Wu C amp ma LISTED Sinergex E GO List of contents Important safety striations 1 1 General safety 1 2 Precautions when working with Features 2 1 PROG AO TRO cm 2 2 nin n iip rix ea ERE Re RAI EE 2 3 Mechanical draWindgS ton Se oar n Rue Introduction 3 1 Front panel 3 2 RE RR QUK ERE 3 3 instalation 3 4 Quick hook up and 3 5 safety sr te ed dE 3 6 Making DC wire 3 7 P 3 8 Troubleshooting Maintenance i Mtr Appendices A 7 1 Dip switch C11 7 2 Dip switch 220V s sss Appendices B 8 1 Operations o
3. can be one of the following 0 Power off power consumption 2W restart time lt 5 sec 1 Power off power consumption lt 20W restart time 2 sec 2 Power on 3 Inquire the status of power on off status the response information would be either 0 OFF or 1 OFF or 2 ON 23 8 2 2 5 To query status command Format STUS value Illustration Don t need to add any of parameter To respond the result be hexadecimal code replaced by 2 ASCII codes that is between 00 FF 0 255 then convert the Hex code to the binary digit after obtaining 8 bytes digit that can be one of following pg B3 BA B5 BG B7 UVP LSB OVP OLP Loading gt 110 FLP Loading gt 100 3 min OTP BATT Too Low BATT Too High BATT Too High MSB 24 Sinengex 8 2 2 6 To query battery level command Format value Illustration Don t need to add any of parameter To respond the result be Hexadecimal code replaced by 2 ASCII codes and is between 00 OB then convert into decade digit after obtaining a digit between 0 11 that can be one of following Hex Decade Indication code code 00 0 LED 1 glows blinking to indicate low voltage 01 1 LED 1 glows solid 02 2 LED 2 glows solid 03 3 LED 3 glows solid 04 4 LED 4 glows solid 05 5 LED 5 glows solid 06 6 LED 6 glows solid 0
4. The communication BAUD RATE should be set to 4800bps S5 amp S6 OFF LED Indications 9 1 3 Turn on the switch of the Inverter There will be two short beep sounds from the Inverter All LEDS will be ON and one second later there will be a short Beep sound The amber green and red LEDS of remote controller will be on for 0 5 second then off sequentially The Inverter is then in the OFF mode The amber LED will be blinking every 2 3 seconds 9 1 3 1 Remote Controller LEDS Color Status Power Saving Power Output Green ON Enable ON Green Blinking Enable OFF Amber ON Disable ON Amber Blinking Disable OFF Green Power saving enable Amber Power saving disable ON Power On Blinking Power Off 27 Sinergex Operations 9 1 4 9 1 5 9 1 6 9 1 7 9 1 8 Set SLIDE SW ON Keypads will not work if SLIDE SW is set OFF Remote ON OFF Pressing a button and releasing in one second will change toggle the output ON OFF mode and the display of LEDS will be changed accordingly Operations of power saving mode Press the button for 2 seconds and the colors of LED will be changed Keep pressing the button and the colors will be toggling between amber and green every 2 3 seconds The color of LED will determine the mode of operation Green indicates that power saving mode is enabled and amber indicates is disabled Release the button when the L
5. and all loads are disconnected 9 2 5 1 Switch on the inverter There will be 2 beeps and the green led will start flashing with a flashing sequence of flash flash flash After about 3 seconds there will be 1 beep the green led will stop flashing and it will be lighted continuously Output power will be available after about 15 to 18 sec from the time the green led stops flashing After the output power is made available the inverter searches if any load is connected If the load is less than 2 to 15 watts the output power is shut down after about 15 seconds from the time the output power is made available The green led will start a flashing sequence of flash flash gap flash Flash gap this indicates that the inverter is in power saving sleep mode and is idling at no load 30 Sinengex 9 2 6 9 2 5 2 9 2 5 3 If now load more than 2 to 15 watts is switched on the green led stops flashing after about 3 seconds and will be lighted continuously After about 15 to 18 seconds after the green led has stopped flashing and become steady output power will be available to the load The green led will be lighted continuously this indicates that the inverter is in power saving sleep mode and is in loaded condition If the load is switched off the output power will be shut down after about 15 to 18 seconds and the green led will start flashing with a flashing sequence of flash flash gap flash flash gap
6. feet 1500 INLINE FUSE Sinengex 3 7 Inverter Operation To operate the power inverter turn it ON using the power ON OFF switch on the front panel The power inverter is now ready to deliver AC power to your loads If you are operating several loads from the power inverter turn them on separately after the inverter has been turned on This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once 3 7 1 Controls and indicators The ON OFF switch turns the control circuit in the power inverter on and off It does not disconnect power from the power inverter The PS 1500 Inverter operates from an input voltage ranging from 10 5 to 15 0 VDC for 12V models 21 0 to 30 0 VDC for 24V models 42 0 to 60 0 VDC for 48V models The PS 1500 Inverter will indicate high and low DC voltage conditions as follows Model Dc Input over Dc Input under Dc Input under ids voltage shut down voltage alarm voltage shut down PS 1500 112 16 7VDC 10 2VDC 9 5VDC PS 1500 212 PS 1500 124 33 4VDC 20 4VDC 19 0VDC PS 1500 224 PS 1500 148 62 0VDC 41 6VDC 40 0VDC PS 1500 248 Sinengex 3 7 2 3 7 3 3 7 4 3 7 5 3 7 6 3 7 7 Battery voltage indicator The battery voltage bar graph indicates the voltage at the input terminals of the power inverter At low input current this voltage is very close to the battery voltage At high i
7. 232 command Command format This unit uses high level language commands with a CR ODH and a LF OAH as the end of the command The system would interpret and execute the command only after these two characters are received After the unit execute the command it would send a response string to the computer The response string is as follows gt CR LF Command executed successfully gt CR LF Command error not accepted gt CR LF Command correct but execution error e g parameters out of range If the command needs any information from the unit The unit would send the information back to the computer with CR and LF and then send the response string to the computer 22 Sinengex 8 2 2 2 8 2 2 3 8 2 2 4 Command format This unit supports the following commands There should always be a ODH and a LF OAH appended to the command while sending the command to this unit PWRS command Power saving function control Format PWRS lt value gt Illustration A space ASCII code 20H is needed between PWRS and lt value gt value can be one of the following 0 Power saving disable 1 Power saving enable 2 Inquire the status of saving the response information would be either 0 disable or 1 enable Power command Power ON OFF control Format Power value Illustration A space ASCII code 20H is needed between PWRS and lt value gt value
8. 7 7 LED 7 glows solid 08 8 LED 8 glows solid 09 9 LED 9 glows solid 0A 10 LED 10 glows solid OB 11 LED 11 glows blinking to indicate over voltage 00 0 LED 1 glows blinking to indicate low voltage 01 1 LED 1 glows solid 25 Sinengex 8 2 2 7 To query load level command Format Load value Illustration Don t need adding any of parameter Respond The same as value value can be one of following Hex Decade Indication code code 00 0 Load lt 5 All of LED indicators go OFF 01 1 Load 1596 LED 1 indicator glows 02 2 Load lt 25 LED 1 LED 2 indicators glow 03 3 Load 3596 LED 1 LED 3 indicators glow 04 4 Load lt 45 LED 1 LED 4 indicators glow 05 5 Load 5596 LED 1 LED 5 indicators glow 06 6 Load lt 65 LED 1 LED 6 indicators glow 07 7 Load 7596 LED 1 LED 7 indicators glow 08 8 Load 8596 LED 1 LED 8 indicators glow 09 9 Load lt 95 LED 1 LED 9 indicators glow 10 Load lt 105 LED 1 LED 10 indicators glow OB 11 Load gt 105 All of LED indicators Blinking 06 6 Load lt 65 LED 1 LED 6 indicators glow 07 7 Load lt 75 LED 1 LED 7 indicators glow 26 Sinengex 9 Appendices C 9 1 Remote Control Operations System Configuration 9 1 1 Plug the 9 pin D SUB connector of the remote controller in the RS 232 port of the Inverter 9 1 2 Check the setting of DIP SW S5 amp S6
9. ED indicating the desired status is reached The operation power saving enable disable does not change the power ON OFF mode Despite the setting of power saving mode when a power OFF command is set by pressing a button the power will be turned OFF and the power saving mode will be set to disable automatically amber LED will flash for 2 3 seconds When the power is turned ON the power saving mode will restore the previous setting 28 Sine gex 9 2 Power saving mode SINERGEX MICROPROCESSOR BASED SINE WAVE INVERTER PS 1500 SERIES ENABLING AND DISABLING POWER SAVING MODE 9 2 1 When an inverter is powered on and is running in idle condition there is no load or the load connected to the inverter has been switched off it will still draw some power from the batteries for keeping the system alive 9 2 2 This inverter features a power saving sleep mode for conserving the battery power during idle conditions When this mode is enabled the inverter senses the output power being drawn and if this is less than 2 to 15 watts the inverter shuts down the output power Only essential systems are kept alive to reduce power consumption from the batteries to a very low value of only about 1 5 watts As soon as a load is switched on the inverter wakes up from its sleep condition and restores the output power after a response time of about 8 seconds Please note that on waking up from the power saving sleep mode the inverter requi
10. N50081 1 1992 EN50082 1 1992 EM EN55022B 1994 e Mark EN61000 4 2 1995 e13 020932 EN61000 4 3 1996 ENV50204 1995 Operating Temperature Range 401 Storage Temperature Range 300 to 700 Dimensions 390 L x 275 W x 105 H mm 15 4 L x 10 8 W x 4 1 H Inch Cooling Thermostatically controlled cooling fan Weight 7 0kgs 15 5 16 Si LEER S Sa PS 2 3 Mechanical Drawings PE OOS 78 Vo m ox FN D LH amp plain wo te E ls 2 to no 00 ne x to N 5 e ia J WATTS SVITCH SELECTABLE _ MU 31500 14 _ NNNANAANNANNANNNANNANANANANNANNANANNNNANANANNNNAANANNNNAAANNNL i r SINF WA ERTER ve cue maven eT Mee se md ome 7500 E 8 OFF PUT 220 230 240 SIVGD4z SVITCH SELEC WOE 515 AC 50 60Hz SWITCH SELECTABLE ODEL 500 224 AAQANAAANAAANAAAAANAAAANANANANNAANAAAAAAAANA Sinengex 3 Introduction The Sinergex PureSine power inverters are some of the most advanced mobile power products available To get the most out of your PureSine 1500 it must be installed and used correctly Please read the instructions
11. battery cables to the DC input terminals on the PS 1500 Inverter Your cables should be as short as possible ideally less than 10 feet 3 meters and large enough to handle the required current in accordance with the electrical codes or regulations applicable to your installation Cables that are not an adequate gauge too narrow or are too long will cause decreased inverter performance such as poor surge capability and frequent low input voltage warnings and shutdowns These low input voltage warnings are due to DC voltage drop across the cables from the inverter to the batteries The longer and narrower these cables the greater the voltage drop WARNING Failure to place a fuse on the positive cable Between the inverter and the battery may cause damage to the inverter and void warranty Sinergex 12 WARNING The installation of a fuse must be on the positive cable Failure to place a fuse the cable between the inverter and battery may cause damage to the inverter and will void warranty Increasing your DC cable size will help improve the performance Our Company recommends the following cables for optimum inverter performance apply both 120V and 230V versions Model No Wire AWG Inline Fuse PS 1500 112 2 200 PS 1500 212 2 200 PS 1500 124 4 130 PS 1500 224 4 130 Also use only high quality copper wiring and keep cable length short maximum of 3 6
12. ck its performance before final installation please follow these guidelines 3 4 1 Unpack and inspect the power inverter Check to see that the power switch is in the OFF position 3 4 2 Connect the cables to the power input terminals on the rear panel of power inverter The red terminal is positive and black terminal is negative Insert the cables into the terminals and tighten wires securely WARNING Make sure the DC terminal connections are tight and secure torque to 9 10 ft lbs 11 7 13Nm Loose connections will overheat and could result in a potential hazard 3 4 3 Before proceeding further carefully check that you have connected ables to the DC terminals correctly That is the RED cable to the positive terminal and the black cable to the negative terminal CAUTION and may cause permanent damage to the inverter Damage caused by reverse polarity is not covered by warranty Sinergex 3 4 4 Connect the cable from the negative terminal of the inverter to the negative terminal of the power source Make a secure connection WARNING You may observe a spark when you make the connection since current may flow to charge capacitors within the inverter Do not connect the inverter to your power source in the presence of flammable fumes Explosion or fire may result 3 4 5 Set the power switch to the ON position Check the meters and indicators on the front panel of the inverter The voltag
13. d cable 110V 95 105VAC voltmeter 220V 190 210VAC See page 10 Point 3 4 7 of manual Load LED bar flash Overload Reduce load No output voltage And voltage indicator in lower red zone Low input voltage Recharge battery check connections and cable Sinengex No output voltage Over Temp indicator on load less than 1500W Thermal shutdown Improve ventilation Make sure ventilation openings in inverter are not obstructed Reduce ambient temperature No output voltage Over Load indicator On Short circuit or Wiring error Very high power load Check AC wiring for short circuit or improper polarity hot and neutral reversed Remove load Sinengex 5 Maintenance Very little maintenance is required to keep your inverter operating properly You should clean the exterior of the unit periodically with a damp cloth to prevent accumulation of dust and dirt At the same time tighten the screws on the DC input terminals 6 Warranty We warrant this product against defects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective Power Inverter when directly returned postage paid to us This warranty will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally and does not cover damage arising from improper use such as connecting the unit into an unsui
14. e bar graph should indicate 11 to 14 volts 22 to 28V when 24V version is used depending on the voltage of the power source If it does not check your power source and the connections to inverter All other indicators should be off 3 4 6 Set the power inverter switch to the OFF position the indicator lights may blink and the internal alarm may sound momentarily The is normal Plug the test load into the AC receptacle on the front panel of the inverter 3 4 7 Set the power inverter switch to the ON position and turn the test load ON The inverter should supply power to the load If you plan to accurately measure the true output r m s voltage of inverter a meter such as FLUKE 45 BECKMAN 4410 or TRIPLETT 4200 must be used Siengex 3 5 AC Safety Grounding 3 5 1 During the AC wiring installation AC input and output ground wires are connected to the inverter The AC input ground wire must connect to the incoming ground from your AC utility source The AC output ground wire should go to the grounding point for your loads for example a distribution panel ground bus Neutral Grounding GFCI S 3 5 1 1 3 5 1 2 120V models The neutral conductor the AC output circuit of the PS 1500 Inverter is automatically connected to the safety ground during inverter operation This conforms to National Electrical Code requirements that separately derived AC sources such as inverter and generators have their neutral conduc
15. er RXD RXD TXD TXD DSR DIR RTS CTS GND The RS232 interface of this unit employs ASCII code to implement the asynchronous serial transmission control The byte structure is START BIT 8 BIT DATA STOP BIT Baud rate 1200 2400 4800 SET BY DIP SW Parity check NONE not settable Data bit 8 not settable Stop bit 1 not settable 21 Sinengex 8 2 Interface Command The buffer size used for the RS232 port is 12 bytes This unit will ignore all bytes more than this value During transmission this unit inverter will indicate it is ready to receive data from computer by the DTR line A computer has to check the DTR line before sending any information to this unit This unit is normally always ready to receive data while operating When LF character ASCII code OAH is received this unit would finish the receiving by clearing the DTR status and begin to interpret the received information The unit would execute the received command AND OR data if it is correct Irrespective of whether the command is accepted or not the unit will always send back a response signal to the computer and set to ready for receiving more incoming information 8 2 1 The Baud Rate of the RS232 interface is determined by S5 and S6 of DIP SW as shows in Appendix A Note You have to reset the unit after adjustment to activate the New settings 8 2 2 Illustration of the RS232 operation 8 2 2 1 RS
16. f RS232 serial 8 2 Interface command 9 1 Remote control 9 2 Power Saving Ide Sinergex 1 Important Safety Instructions WARNING Before you install and use your PS 1500 be sure to read and Save these safety instructions 1 1 General Safety Precautions A 1 1 2 1 1 3 Do not expose the PS 1500 Inverter to rain snow spray bilge or dust To reduce the risk of hazard do not cover or obstruct the ventilation openings Allow good air flow to the inverter Do not install the PS 1500 Inverter in a zero clearance compartment Overheating may result To avoid the risk of fire and electric shock make sure the existing wiring is in good electrical condition and that wire size is not undersized Do not operate the PS 1500 Inverter with damaged or substandard wiring This equipment contains components which can produce arcs or sparks To prevent fire or explosion do not install in compartments containing batteries or flammable materials or in locations that require ignition protected equipment This includes any space containing gasoline powered machinery fuel tanks or joints fittings or other connections between components of a fuel system Sinengex 1 2 Precautions When Working
17. in this manual before installing and using the inverter 3 1 Front Panel Operation 3 1 1 Front View 3 1 2 ON OFF Switch Power ON OFF switch Leave in OFF position during installation 3 1 3 Power Saving Power energy saving enable OVP Over Voltage Protection UVP Under Voltage Protection OTP Over Thermal Heating Protection OLP Over Load Protection Input Volts Input Voltage Display Load Watts AC Load Wattage Display sinergex 3 1 4 AC outlet Outlet sockets available North America GFCI North America Continental European Schuko Australia New Zealand United Kingdom 3 2 Rear Panel Operation 3 2 1 Ventilation Openings Do not obstruct Allow at least 1 inch for air flow 3 2 2 Battery terminals Connect to 12V 24V 48V battery or other 12V 24V 48V power source is positive BLACK is negative Reverse polarity connection will blow internal fuse and may damage inverter permanently 3 2 3 RS 232C Connect to remote control unit optional accessory or control remotely by computer 3 2 4 Connect chassis ground terminal to earth or to vehicle chassis using 8 AWG wire WARNING Operation of the inverter without a proper ground connection may result in an electrical safety hazard Sinergex WARNING Shock Hazard Before proceeding further carefully Check the inverter is NOT connected to any batteries and all wiring is disconnected from any electrical sources D
18. indicator indicates that the power inverter has shutdown because its output has been short circuited or drastically overloaded Switch the ON OFF switch to OFF decrease your power load and then switch the ON OFF switch back to ON to reset the unit Sinergex 3 8 Power output The 1500W inverter will operate most AC loads within its power rating When deeming whether a microwave oven can be operated by the 1500W inverter remember that the power commonly advertised for microwave ovens are the cooking power the power delivered to the food not the power actually consumed by the microwave oven The microwave oven will consume 40 to 100 more than its advertised cooking power Check the rating sticker on the back of the oven to determine its actual power requirements The 1500W inverter will operate small microwave oven 0 2 to 0 3 cubic foot capacity that draws about 1700 watts It will provide 3 minutes of cooking time Some induction motors used in refrigerators freezers pumps and other motor operated equipment require very high surge currents to start The Power Inverter may not be able to start some of these motors even though their rated current requirement is within the power inverter If a motor is unable to start observe the battery voltage indicator while trying to start the motor If the battery voltage indicator drops below 11 volts while the inverter is attempting to start the motor this may be why the motor won t start Make su
19. inverter or with the help of the optional remote control Switching between the states using the power on off switch on the front plate of the inverter is done as follows This procedure acts as a toggle i e if the inverter was in enabled state before the procedure it will switch to disabled state after the procedure Likewise if it was in disabled state before the procedure it will switch to enabled state after the procedure Switch off all the loads switch off the inverter and disconnect all loads Switch on the inverter There will be 2 beeps and green led will start flashing with a flashing sequence of flash flash flash it will flash for approx 3 seconds Immediately after it starts flashing switch off the power off switch and immediately switch on again This will complete the switching procedure The inverter will continue its power on sequence and switch over to the new state The power on off switch should be switched off and on again during the time the green led is flashing the green led will flash with a sequence of flash flash flash For about 3 seconds after the inverter is powered on 32
20. nput current this voltage will be lower than the battery voltage because of the voltage drop across the cable and connections Ideally the voltage should remain in the green areas of the bar graph If the voltage goes into the red area at the top and bottom of the graph the inverter may shutdown Load watt indicator The AC load wattage bar graph indicates the power drawn from the power inverter by the load For long term operation the wattage indicator should remind in the green amp orange areas of the bar graph Short term operation is possible with the wattage indicator in the red area If the wattage indicator rises to high values the bar will flash and the inverter will shutdown to protect itself Over voltage indicator The over voltage indicator indicates that the power inverter has shutdown because its input voltage exceeded 12 24V 48VDC version Under voltage indicator The under voltage indicator indicates that the power inverter has shutdown because its input voltage fell below 12 24V 48VDC Over temp indicator The over temp indicator indicates that the power inverter has shutdown because its temperature has become to hot The power inverter may overheat because it has been operating at power levels above its rating or because it has been installed in a location which does not allow it to dissipate heat properly The power inverter will restart automatically once it has cooled Overload indicator The overload
21. o no connect the output terminals of the PS 1500 Inverter to an incoming AC source 3 3 Installation Where to install The power inverter should be installed in a location that meets the following requirements 3 3 1 Dry Do not allow liquid to drip or splash on the inverter 3 3 2 Cool Ambient air temperature should be between 0 and 40 degrees Celcius The cooler the environment the better 3 3 3 Safe Do not install in a battery compartment or other areas where flammable fumes may exist such as fuel storage areas or engine compartments 3 3 4 Ventilated Allow at least one inch of clearance around the inverter for air flow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed 3 3 5 Dust Free Do not install the PS 1500 Inverter in dusty environments where contaminants such as dust wood particles or other filings or shavings These particles can be pulled into the unit when the fan is operating 3 3 6 Close to batteries Avoid excessive cable lengths but do not install the PS 1500 Inverter in the same compartment as batteries Use the recommended wire lengths and sizes see section 2 10 Also do not install the inverter where it will be exposed to the gases produced by the battery These gases are very corrosive and prolonged exposure will damage the PS 1500 Inverter Sinergex 3 4 Quick hook up and testing For a quick hook up and test of the inverter to che
22. re that the battery connections are secure and the battery is fully charged If the connections are secure and the battery is fully charged but the voltage still drops below 11 volts you may need to use a larger battery Sinengex 4 Troubleshooting guide WARNING Do not open or disassemble the PS 1500 Inverter Attempting to service the unit yourself may result in a risk of electrical shock or fire and void warranty Common problems Television interference Operation of the power inverter can interfere with television reception on some channels If this situation occurs the following steps may help to alleviate the problems Make sure that the chassis ground lug on the back of the power inverter is solidly connected to the ground system of your vehicle boat or home Do not operate high power loads with the power inverter while watching television Make sure that the antenna feeding your television provides an adequate snow free signal and that you are using good quality cables between the antenna and the television Move the television as far away from the power inverter as possible Keep the cables between the battery and the power inverter as short as possible and twist them together with about 2 to 3 twists per foot This minimizes radiated interference from the cables Problems and Symptoms Possible Cause Solutions Low output voltage Using average reading Use true RMS reading meter an
23. res some time to prepare all the systems before it can start delivering power to the load Hence the output power will not be available immediately but after a time lag of approx 15 to 18 sec If using a hand tool or other appliance with a trigger keep the Trigger pressed for some time till the power is available to drive the tool appliance 9 2 3 The power saving sleep mode can be enabled or disabled with the help of the power on off switch or with the help of the optional remote control Procedure to switch between the two states are given in paragraph 6 below The inverter has been factory pre set in the enabled condition 29 Sinergex 9 2 4 9 2 5 Power saving sleep mode enabled 9 2 4 1 9 2 4 2 The front plate has a green led marked power saving for indication of enabled state of power saving sleep mode here in after referred to as the green Led The power saving sleep mode is enabled in either Of the following indications when inverter is in on condition The green led flashing sequence is flash flash gap flash flash gap power saving sleep mode idle condition or no load The green led is continuously lighted power saving sleep mode loaded Following indications will be observed when the inverter is powered on and subsequently loaded and unloaded when power saving sleep mode is in enabled condition the initial condition is that the inverter is switched off
24. table power source attempts to operate products with excessive power consumption requirements or use in unsuitable environments This is the only warranty that the company makes No other warranties express or imply including warranties of merchantability and fitness for a particular purpose Repair and replacement are your sole remedies and the company shall not be liable for damages whether direct incidental special or consequential even though caused by negligence or other fault Sinengex 7 Appendices 7 1 Dip Switch 110V 51 2 VOUT 55 56 BAUD VAC Hz RATE ON ON 100 ON 50 ON ON 1200 OFF ON 110 OFF 60 OFF ON 2400 ON OFF 115 OFF 4800 OFF OFF 120 OFF OFF 4800 7 2 Dip Switch 220V S1 s2 VOUT FREQ s5 56 BAUD VAC Hz RATE ON ON 200 ON 50 ON ON 1200 OFF ON 220 OFF 60 OFF ON 2400 ON OFF 230 ON OFF 4800 OFF OFF 240 OFF OFF 4800 S4 is unavailable 20 Sinengex 8 Appendices B 8 1 Operations of RS232 Serial Port 8 1 1 8 1 2 8 1 3 Hardware design This unit uses a 9 pin D connector and three of RS232 signal lines RECEIVE DATA RXD PIN2 TRANSMIT DATA TXD DATA TERMINAL READY PIN4 The connection between this unit and a computer is as follows Computer Power invert
25. tors tied to ground in the same way that the neutral conductor from the utility is tied to ground at the AC breaker panel For models configured with a transfer relay while AC utility power is present and the PS 1500 Inverter is in bypass mode this connection neutral of the PS 1500 Inverter s AC output to input safety ground is not present so that the utility neutral is only connected to ground at your breaker panel as required 230V models There is no connection made inside the PS 1500 Inverter from either the line or neutral conductor to the safety ground Sinengex Ground Fault Circuit Interrupters GFCI Installations in Recreational Vehicles for North American approvals will require GFCI protection of all branch circuit connected to the AC output of the hardwire terminal equipped PS 1500 Inverter In addition electrical codes require GFCI protection of certain receptacles in residential installations While the pure sine wave output of the PS 1500 Inverter is equivalent to the waveform provided by utilities compliance with UL standards requires us to test and recommend specific GFCI Our Company has tested the following GFCl protected 20A receptacles and found that they functioned properly when connected to the output of the PS 1500 Inverter WARNING Do not operate the power inverter without Connecting to ground Electrical shock me result 3 6 Making DC Wiring Connections Follow this procedure to connect the
26. uum cleaners fans fluorescent and incandescent lights shavers sewing machines etc Kitchen Items microwave ovens refrigerators and freezers coffee makers blenders ice makers toasters etc Home entertainment electronics televisions VCRs DVD players video games musical instruments satellite equipment Hi Fi equipment etc Industrial equipment work lights etc Sinergex 2 2 Electrical Performance Specification Model No PS 1500 1 PS 1500 1 PS 1500 1 PS 1500 2 PS 1500 2 PS 1500 2 12 24 48 12 24 48 Continuous Output Power 1500W Surge Rating 2000W Input Voltage 12V 24V 48V 12V 24 48V Output Voltage 100 110 115 120V 3 200 220 230 240V 3 a 50 60Hz 0 05 Peak Output Current 25A 11A Efficiency full load 8596 8796 8896 86 89 90 No Load Current Draw 1 5W Saving Mode Output Waveform Sine Wave lt 3 THD Output Voltage Regulation 100 110 115 120V 200 220 230 240V RMS 10 4 RMS 10 4 Input Voltage Regulation 10 16 VDC 20 32 VDC 42 62 VDC 10 16 VDC 20 32 VDC 42 62 VDC Overload Short Circuit Reverse Polarity Fuse Over Under Input Protecion Voltage Over Temperature Power Saving Recovery 5 Second Time Interface Control Port RS 232C With Baud Rate 1200 2400 4800 Switch Selectable Remote Control Unit Optional Safety UL458 EN60950 E
27. with Batteries 1 2 1 If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eyes immediately flood eye with running cold water for at least 20 minutes and get immediate medical attention 1 2 2 NEVER smoke or allow a spark or flame in vicinity of battery or engine 1 2 3 Do not drop a metal tool on the battery The resulting spark or short circuit on the battery or other electrical parts may cause for or an explosion 1 2 4 Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A lead acid battery produces a short circuit current high enough to weld a ring or alike to metal causing severe burns Sinergex 2 Features e Pure sine wave output lt 3 THD e Output frequency 50 60Hz switch table e Low power Power Saving Mode to conserve energy e RS 232C interface remote controls port e Built in voltage and watt meter Thermostatically controlled cooling fan e Advanced microprocessor design Protection Input low voltage Overload Short circuit Low battery alarm Input over voltage Over temperature 2 1 Application 2 1 1 2 1 2 2 1 3 2 1 4 2 1 5 2 1 6 Power tools circular saws drills grinders sanders jigsaws weed and hedge trimmers air compressors Office equipment computers printers monitors facsimile machines scanners etc Household items vac