Home
Installing BioWin 3.1 ML under Windows 7™
Contents
1. 1 From the Start menu open Control Panel and click Clock Language and Region E gt Control Panel Adjust your computer s settings System and Security Review your computer s status Back up your computer Find and fix problems Network and Internet View network status and tasks Choose homegroup and sharing options 82 ay 7 Hardware and Sound View devices and printers Z l Add a device S Programs ay Uninstall a program May 5 2010 View by Category User Accounts and Family Safety Add or remove user accounts la Set up parental controls for any user Appearance and Personalization Change the theme Change desktop background Adjust screen resolution Clock Language and Region Change keyboards or other input methods Ease of Access Let Windows suggest settings Optimize visual display Page 4 of 13 1 On the Formats tab select Chinese Simplified 2 On the Administrative tab click Change system PRC from the drop down list locale Region and Language Region and Language Formats Location Keyboards and Languages Administrative Formats Location Keyboards and Languages Administrative Format Welcome screen and new user accounts English Canada MA View and copy your international settings to the welcome screen system accounts and new user accounts Date and time formats Short date Cammy e Long date Tell
2. Carbon dioxide content Dissolved N2 gas production rate ni issalved AI ase mradiuc nt value Special Functions Imported General plot State variables Selected variables Non polyP heterotrophs Anoxic methanol utilizers Ammonia oxidizing biomass Nitrite oxidizing biomass m PolyP heterotrophs Propionic acetogens Acetoclastic methanogens Hydrogenotrophic methanoger Duplicates Plot Type f Concentration flows Mass rates C Composite samples C Surface plot han rake norr Selected elements Plot selected Some of the BioWin Versi additions changes and upgrades in BioWin 3 1 are listed here A number of the features added to on 3 0 are also listed as a reminder to users Linking to BioWin Controller BW Controller is a separate Windows application which links to a BioWin configuration and allows specification of a range of process control features commonly employed in wastewater treatment systems Start BW Controller To start click on the Start BW Controller button at the right on the toolbar in BioWin to link the control application to the BioWin configuration BW Controller includes its own Help and Tutorials Model Additions and Enhancements The addition plants BioW s to the Full Plant Edition of BioWin are significant advances in modeling of wastewater treatment in tracks more organic and inorganic components than any ot
3. Getting started A good starting point is to print out the Tutorials chapter and use this to get familiar with BioWin It s all in the Help but having a hardcopy may be easier for the initial steps After you install there is a document called TUTEXAM PDF in the MISC subdirectory of the BIOWIN 3 1 ML directory Alternatively look on the CD in the MANUAL directory Running BioWin 3 1 Multi language The BioWin 3 1 ML folder in the Start menu contains two shortcuts to run BioWin e BioWin 3 1 to run BioWin in English e BioWin 3 1 Multi language to run BioWin in Chinese French German or Spanish The language settings of the computer determine the language that BioWin will use It is important that the computer is set up to display the desired language correctly Running BioWin in English 1 To run BioWin in English click the BioWin 3 1 shortcut in the Start menu gl Windows Update ea XPS Viewer di Accessories BioWin 2 BioWin 3 BioWin 3 1 ML Br BioWin 3 1 Multi language Ee BioWin 31 TH BioWin Feature Tour BioWin Tutorials r 4 Back Running BioWin in French German or Spanish 1 From the Start menu open Control Panel and click Clock Language and Region ee Ex Control Panel gt v Search Control Pane Adjust your computer s settings System and Security Review your computer s status Back up your computer Find and fix problems View network status and
4. mixing 5 00 w m3 Air flow 110 78 W m3 Velocity gradient 349 35 7s Model options BioWin AS AD model Builder model Oxygen modeling pH calculation pH limitationin AS Struvite amp Ca Phosphates precipitation Fe Precipitation Modified Vesi Status Steady state solution SRT days 23 33 Ready to simulate 20 0 C 1 0 hours Current alarms 0 Microscreen element A new process flowsheet element has been added for microscreens Units with mesh sizes of say 200 to 300 microns are used in Cannibal type systems for screening a portion of the RAS flow see example configuration below Experience indicates that these units preferentially screen out unbiodegradable inert particulate VSS XI from the mixed liquor The user specifies the flow split for the unit by adjusting the flow split the user can modify the solids of the so called trash The user also specifies the percent solids capture and the additional capture of volatile particulate inerts Adjusting the two capture rates allows the user to modify the VSS TSS composition of the trash ea BioWin Simulator Canni File Edit Tools Project View Simulate Help DA IRISINSHB alv Fo amp 5 ioe B Main Configure Influent Aerobic Effluent Microscreen Name Trash Type Sludge Flow 2 47 m3 d 35 4 VSS as of TSS 95 76 N as 4 of TSS 6 38 Pas of TSS 2 00 pH 6 68 TSS 875 57 kgd VSS 838 42 kg d Model options BioWin AS A
5. copy of BioWin are shown below Different types of Hardlock keys from left to right Network version parallel port key standard parallel port key USB key and PCMCIA key The Hardlock USB is equipped with an LED which shows the status of the protection module If you are using the USB key and after you plug the Hardlock Aladdin key into the USB port the LED does not light up or if it flashes see the section Hardlock USB key status information in Appendix 1 4 Lease Activation Code When you first run BioWin after installing you will be prompted to enter a Lease Activation Code This is located on a sticker on the back of the CD case Type the code in and press the Apply Lease Code button note that the code is NOT case sensitive A common error is pressing the OK button instead of the Apply Lease Code button 5 Help F1 BioWin employs the latest in Help delivery technology HTML help This launches with a look and feel consistent with Microsoft Office products For tips on using this effectively look in the Help press the F1 button under the Getting Help in BioWin chapter 6 Manual BioWin does not ship with a printed manual However if you want to print the manual it has been shipped as an Adobe PDF This document can be found on your PC in the MISC subdirectory of your BioWin installation directory the typical path is C PROGRAM FILES ENVIROSIM BIOWIN 3 1 ML MISC but depends on where you installed 7
6. information General The Aladdin Hardlock End User s Manual is in the document hlendusersmanual_en pdf which is located in the MANUAL directory on the installation CD ROM The document contains detailed information about the Hardlock module installations procedures and troubleshooting information If you have purchased a server version of the software the document also describes the HL Server and utility software Hardlock USB key status information Hardlock USB is equipped with an LED display which shows the status of the protection module LED display Status o O The module is not recognized Possible reasons No driver no USB support module not functioning LED does not light LED flashes at approx 2 Hz The module is recognized but not initialized correctly Possible reasons Memory defective module not encoded as a Hardlock module module not functioning LED lights up The module is recognized and initialized correctly If your USB key LED is steadily lit then the hardware should be functioning correctly and it is likely that your problem is not related to the installation of your key BioWin Hardlock key messages BioWin error message Possible reasons Error Unable to find Key The key is not plugged in or could not be found OR The key driver software is not properly installed All network licenses in use If you have a server version of the software then either the Hardlock server cannot be found or a
7. tasks lt Choose homegroup and sharing options G Network and Internet u 7 Hardware and Sound gel View devices and printers Add a device Programs Uninstall a program Gera User Accounts and Family Safety W Add or remove user accounts W Set up parental controls for any user Appearance and Personalization Change the theme Change desktop background Adjust screen resolution Clock Language and Region Change keyboards or other input methods Ease of Access Let Windows suggest settings Optimize visual display 2 Onthe Formats tab select the desired language from the drop down list and click OK Region and Language Formats Location Keyboards and Languages Administrative Format Date and time formats Short date Long date Short time Long time First day of week What does the notation mean Examples Short date Long date 09 02 2010 February 09 10 10 25 AM 10 25 33 AM Short time Long time Go online to learn about changing languages and regional formats Running BioWin in Chinese 3 Torun BioWin in the selected language click the BioWin 3 1 Multi language shortcut in the Start menu Ef Windows Update lt a XPS Viewer di Accessories Ji BioWin 2 BioWin 3 ioWin 3 1 Multi language B w BioWin 3 1 rA BioWin Feature Tour TH BioWin Tutorials Back c J eo JCC TC programs and Pubes L _
8. D model Builder model Oxygen modeling pH calculation pH limitationin AS Struvite amp Ca Phosphates precipitation Fe Precipitation Modified Vesi Status Steady state solution SRT days 61 84 Ready to simulate 20 0 C 1 0 hours Current alarms 0 Cyclone elements Two new process flowsheet elements have been added to BioWin for the simulation of cyclone separation processes an ISS cyclone and a Dewatering DW cyclone These units are used in Cannibal type systems for preferential removal of inorganic suspended solids ISS which are present in the influent and that accumulate in the mixed liquor In practice the underflow from a cyclone typically is in the range of 20 to 40 percent of the unit input flow but the underflow is directed onto an inclined belt the objective is to largely dewater the underflow leaving behind mainly grit with a high ISS content For each cyclone element the user specifies the flow split by adjusting the flow split the user can modify the solids of the so called grit 1 With the ISS cyclone the user specifies the capture of inert suspended solids ISS The concentrations of other particulate components are the same in the over and underflow 2 In Cannibal type applications the cyclone is used in conjunction with dewatering With the Dewatering DW cyclone the user specifies the percent solids capture and the additional capture of ISS Adjusting the two capture rates allows the user to modify
9. For further details review the Sidestream chapter Denitrification by heterotrophs ordinary heterotrophic organisms OHOs phosphorus accumulating organisms PAOs or methanol utilizing heterotrophs methylotrophs is modeled as a two step process with conversion of nitrate to nitrite and then nitrogen gas Modeling the growth of Anammox bacteria autotrophic organisms that combine ammonia and nitrite to form nitrogen gas without the addition of organic substrate For further details review the Sidestream chapter Usability Enhancements A number of features have been added to BioWin to streamline ease of use Version 3 1 new features Upgraded simplified and more consistent dialogs for setting up parameter plots Improved table displays with options to show element specific variables for different element types concentrations and or mass rates as well as column totals New tables replace aeration tables with the added ability to show and sum aeration details for different element types Ability to duplicate Album pages including charts and series tables and element info displays but excluding any functions Flow option of gal d for small flow elements in U S customary units Auto save BioWin files while you are working on them in addition to dynamic simulation intermediate files Function series that allows a BioWin series to be multiplied by a constant Function periods can be specified as time intervals rather than num
10. McMaster Innovation Park 175 Longwood Road South Suite 114A Hamilton Ontario L8P OA1 oo a CANADA En VIro Sim P 1 905 481 2607 ASSOCIATES LTD F 1 905 481 2610 www envirosim com Installing BioWin 3 1 ML under Windows 7 1 Older Versions of BioWin BioWin 3 1 ML will be installed in a separate directory Please note that this upgrade will not affect older BioWin versions which are separate applications this means that users can keep their older copies of BioWin 2 Installation Do NOT plug the Hardlock Aladdin key into your computer until the installation is complete You must have Administrator privileges to install the software Installation from CD e Insert the CD into the CD drive Installation should start automatically If installation does not begin after several seconds e Open a command prompt click START button type command prompt into the search field and click on command prompt in the selection window e Type D BWML31SETUP exe if your CD drive is another letter replace D with that letter Click OK to start installation e Follow the instructions on the screen Installation from downloaded file e Go to the download location e Double click on BWML31SETUP exe e Follow the instructions on the screen 3 Hardlock After installation and every time you want to run BioWin you must plug the Hardlock Aladdin key into your PC Different types of keys that may ship with your
11. all state variables all biological and chemical reactions as well as pH in all cells during the settling periods 2 Non reactive BioWin still considers all state variables and includes pH calculations however BioWin ignores biological and kinetic chemical reactions during the settling phase 3 Fast BioWin considers only solids settling equations in all cells during settling modes IWA naming convention BioWin 3 1 now allows a third state variable naming convention the IWA naming option displays names according to the new IWA specification This option is selected through the Tools Customize menu Version 3 highlights Development of a sophisticated biofilm model This has been implemented initially only for Media Bioreactors that is activated sludge suspended growth reactors that contain a free floating carrier media for biofilm growth e g integrated fixed film activated sludge IFAS and moving bed bioreactor MBBR systems The Media Bioreactor module also can be used to configure reasonable representations for other biofilm systems such as trickling filters biological aerated filters and tertiary denitrification filters For further details on the biofilm model review the Biofilm chapter Modeling nitrification as a two step process that is conversion of ammonia to nitrite NO mediated by ammonia oxidizing bacteria AOBs and conversion of nitrite to nitrate NO3 mediated by nitrite oxidizing bacteria NOBs
12. ber of points Ability to monitor plot SBR liquid depth and sludge blanket height Simplified rates window display Improved dynamic simulation speed Features added in Version 3 In ideal separation devices point settlers dewatering units and ideal clarifiers a schedule can be defined to specify time varying percentage removals Oxygen transfer calculations are based on diffuser submergence rather than tank depth When setting up charts in the Album the list of variables that can be plotted is very extensive These have been grouped in separate category lists state variables combined variables water chemistry variables commonly plotted variables This simplifies selecting variables to plot Improved numerical solution techniques and more simulation method options The facility to plot profiles of variable concentrations through layers in the biofilm in Media Bioreactors Itineraries are now completely independent of the constant value Additional alarms to alert the user to unusual conditions Thread process priority management for BioWin users The ability to specify project start time from the project info dialog box Improved grid snap methods Oxygen transfer through the surface in anoxic zones Improved fly by panels The facility to include exclude media from media reactors
13. em has difficulties in finding the Hardlock key there are a number of environment variables that can be used to address these difficulties The environment variables allow you to specifically use the port on which the key is installed change the network search options and control retries and timeouts The section Setting Environment Variables in the document hlendusersmanual_en pdf located in the MANUAL directory on the installation CD ROM describes the use of environment variables BioWin 3 1 Created by process engineers for process engineers New Developments in BioWin The latest version of BioWin provides a host of additions and improvements to enhance your wastewater treatment plant simulations The main additions to Version 3 1 in terms of modeling capacity are e MBR element e Microscreen element e Two cyclone elements ISS cyclone and Dewatering cyclone e Fast SBR model e IWA naming as an option Version 3 1 includes many usability improvements in addition to the model extensions Examples include the facility to specify flows in units of gallons per day useful for specifying small flows for say chemical addition inputs when the selected unit basis is US units automated file backup simplified editing of pipe properties the facility to duplicate pages in the Album by right clicking on the page tab and many more One significant usability improvement is the new interface for adding charts in the Album Previousl
14. her simulator and allows a complete mass balance for recycled sidestreams and supernatants The integrated process model in BioWin works for any environmental condition whether in aerated or unaerated activated sludge tanks fermenters sidestream reactors or digesters This allows seamless integration of the processes in the whole plant A few Version 3 1 highlights MBR element A new process flowsheet element has been added for membrane bioreactors MBRs The MBR unit shown below has two output streams one for permeate and one for mixed liquor from the MBR tank wastage or recycle to upstream reactors The user specifies either the number of membrane modules with editable membrane area and displaced volume per module or the packing density membrane area per unit tank volume Default aeration parameters are set to values typical for coarse bubble aeration Pi 2 yy BioWin Simulator File Edit Tools Project View Main Configure Calculators Influent Effluent 9 4 hours 0 23 mgN L Volume 193 50 f oF m 28 31 mgN L 63 48 i 0 05 mgN L 3 05 z z 7 26 mgP L 6276 mo SS L 9281 mgT55 L 6 00 mg L 6 87 Name MBA Type Membrane bioreactor of Cassettes 10 00 Membrane displaced volume 16 90 Membrane surface area 15168 00 Packing density 78 39 Membrane flux 1 22 L m2 hr Mixed liquor flow 7 57 m3 d OUR 47 55 mgQO L hr OTR 8 51 kg hr Qoffgas dry 2309 65 m3 hr Power dissipation Mech
15. ll the licenses are in use Error Network error If you do not have the server version then key cannot be found If you have a server version of the software then an error in network operation remote was detected This may occur for example if no protocol such as IPX or NetBios is loaded in the local client system Error Accessing required driver A required driver cannot be opened The problem is usually that the driver is not installed Error Too many users The maximum number of users has been reached Error Invalid environment settings The specified environment variable for the API search sequence contains only incorrect entries Error Version mismatch HLVDD DLL During communication the system determined that the HARDLOCK VXD or HARDLOCK SYS HL Server or an installed Hardlock driver is not compatible with the API version being used EnviroSim for a lease renewal Contact EnviroSim to renew your lease now days Your BioWin lease was successfully updated sent BioWin and your lease date has been updated Your BioWin lease was successfully updated An The lease code that you entered was accepted by updated version is available BioWin and your lease date has been updated A minor update of the BioWin software is available that you are using or has been mistyped please contact EnviroSim version version of BioWin purchased Please contact Envirosim Hardlock key search information If your syst
16. me more about these accounts Short time Language for non Unicode programs This setting system locale controls the language used when displaying Long time text in programs that do not support Unicode First day of week Sunday What does the notation mean Current language for non Unicode programs English Canada Examples E Change system locale Short date 09 02 2010 Long date February 09 10 What is system locale Short time 10 25 AM Long time 10 25 33 AM Additional settings Go online to learn about changing languages and regional formats 3 Select Chinese Simplified PRC from the 4 Click OK to accept the changes Windows will drop down list now need to be restarted Region and Language Settings x Select which language system locale to use when displaying text in programs that do not support Unicode This setting affects all user accounts on the System locale has been cha ng ed You must eee restart Windows for the changes to take effect Current system locale a Make sure you save your work and close all open programs before restarting 5 To run BioWin in Chinese click the BioWin 3 1 Multi language shortcut in the Start menu E Windows Update XPS Viewer di Accessories BioWin 2 BioWin3 er BioWin 3 1 Multi language ioWin 3 1 ioWin Feature Tour toWin Tutorials May 5 2010 Page 5 of 13 Appendix 1 Hardlock
17. the VSS TSS composition of the grit The two cyclone elements can be used to achieve the same results namely a flow of grit with a certain VSS TSS composition The ISS cyclone element is provided for users who wish to simulate cyclone operation without dewatering of the underflow Fast SBR Sequencing Batch Reactors SBRs enjoy a wide application in wastewater treatment and BioWin offers a quasi two dimensional approach that is able to simulate situations where quiescent settling is disrupted by flow conditions All this modeling strength comes at a cost more complex and time consuming simulations particularly since the dynamic nature of SBRs means that steady state solution techniques are not appropriate Modeling of the settling phase is particularly intensive because the concentrations of the many particulate components may change slightly as a result of reactions but the settling rate is a function of TSS concentration a composite of many particulates Version 3 1 introduces a fast approximate technique that can allow you to get reasonably close to the solution fast and then turn on the more rigorous modeling to refine your simulations or to ensure that the approximate method reasonable accurately represent the full model Many of the competitors only offer a 1 dimensional approximate technique In Version 3 1 the settling phase in an SBR can be modeled at three different levels of complexity 1 Reactive BioWin considers
18. y when one selected the Add Chart function the resulting dialog had 11 tabs for example Time Series Multi Time Series Mass rates etc The new dialog shown below has been simplified considerably and features have been added The dialog now only has 6 tabs and there is more uniformity between the Time series and Current value tabs In each case plots of flows concentrations or mass rates are generated from one dialog Previously mass rate plots could only be generated for time series and from a separate tab Improvements have also been made to the interface for setting up tables Previously there were separate options for setting up tables of flows concentrations mass rates and aeration details These have now been merged into a single Table editor and concentrations and mass rates can be shown in the same table A facility to totalize columns in tables also has been added E Me Add parameters for plotting a ea a a Time series Curre Combined Alkalinity Filtered COD Particulate TKN pH Soluble PO4 P Total COD Total inorganic N Element specific of aerators of diffusers Actual DO sat conc Air flow rate 7 diffuser Air supply rate Ammonia content Carbonaceous OUR Elements Elements Bioreactor COD Influent Effluent Model clarifier Sludge Splitter Filtered Carbonaceous BOD Total Carbonaceous BOD Total inorganic suspended solids v
Download Pdf Manuals