Home

EE20003

image

Contents

1. N XXX XXX stands for sample quantity 3 Press UNIT key move the digit Press TARE key add up the persent digits GPress ZERO key reduce the persent digits Press PCS key save the above setting you can begin to use this function 9 5 Simple percent counting In counting mode press MODE to change mode or weighting mode 1 Under weighing mode press MODE choose the function Put on the weights screen will display S 100 2 Press MODE key save the above setting you can begin to use this function LED model do not have mode so only change to weighting mode 5 6 Hold function DPress once to lock the persent weight value Press again to cancel lock status This function usually set to close if you want to use this function please contact your local agent 5 7 Printing function connect the balance with PC or printer this function is effective Under weighing mode press the PRINT key to print out percent weight value 5 8 Simple calibration Attentuion Essential to use the standard weight DUnder weighing mode press TARE key 2 seconds to enter simple calibration Press UNIT to move the digits 8 Press TARE key add up the persent digits 4 Press ZERO key reduce the persent digits Put on the right weights the same as the display weight Wait the stable symbol appears for 2 seconds Press MODE key the buzzer will send out a short beep that means simple ca
2. CAUTIONS 2 1 Full charge the battery after unpacking the scale Recharge the battery When battery symbol appears on the LCD display charge the battery with AC adapter the balance of charge will light up in red when it becomes green means charge completed It takes about 8 hours to full charge the battery 2 2 Install the equipment on a level and stable surface 2 3 Do not install the equipment near the air conditioning or a vibrating machine 2 4 Install the equipment in an environment with steady temperature 0 C 40 C prevent from rapid temperature changes 2 5 Independent AC adapter for this equipment is recommended check the Page 1 Balance User Manual 2 6 Warm up the equipment for 15 minutes before use 2 Avoid overloading or dropping material onto the platform 3 INSTALLATION AND START TO USE 3 1 Installation 3 2 Startto use 1 Accessories dG adapter balance body 3 plastic pan 4 SS pan 5 wind shield page 2 Balance User Manual 2 Turn on the indicator 1 Press the ON OFF key 2 Wait till the screen displays 0 00 If it doesn t shows 0 00 press ZERO key to enter weighing mode 4 KEYPAD AND PANEL INTRODUCTION ITEM OPERATION FUNCTION de Power switch ZERO 7 Reset to zero TARE CF Tare des Change the present unit MODE gt Change Weight PCS functions PRINT L gt PRINT Print out the data HOLD gt HOLD Lock the display wei
3. User Manual EE20003 Balance User Manual Contents 1 MAIN FEATURES AND SPECIFICATION _ s_ 1 1 Main Features 0 nn 1 2 Specification ooo eee 2 PRECAUTIONS nennen 3 INSTALLATION AND START TO USE omnes 3 1 Requirements before using 2 weennnnnnnnnnnn nn 3 2 Start to use oO rennen 4 KEYPAD AND PANEL INTRODUCTION een 5 FUNCTIONS AND OPERATION aoue 5 1 Simple Weighing nn 5 2 Tare Function 9 3 Units Shift and Setting I rennen 5 4 Simple counting setting 2 wenn nnnnnnnnnnn 9 5 Simple percent counting 9 6 Hold function gt no 9 7 Printing function ns 6 ERROR MESSAGE AND TROUBLESHOOTING _ m Balance User Manual 1 MAIN FEATURES AND SPECIFICATION Introduction This is a multi function weighing balance that offer flexibility together with good features 1 1 Main features A Automatic zero point tracking function B With multi rang calibration C Tare function D Many units can be selection E Simple counting function and percentage function are applicable F Fast stable and accurate display reading with simple operation 1 2 Specification Capacity g 150 6000 Out Display 1 60000 1 150000 count Resolution Display 6 7 digits LCD display with backlight LED display Tare Full range of max capacity Power supply Rechargeable battery DC 6V 1 3AH Adapter AC 110 220V DC 12V 500mA Temperature Storage 10 50 C Work 0 40 Humidity Storage 5 90 R H Work 10 80 R H 2 PRE
4. ght value LCD MODEL 9600000 HOLD MODE PRINT UNIT TARE ZERO ON OFF Front display pannel Back display pannel Optional Page 3 Balance User Manual LED MODEL Stable Lo Bat Tare Zero Hold Mode Print Unit Tare Zero Front display pannel Stable Lo Bat Tare Zero Back display pannel Optional 5 FUNCTIONS AND OPERATION 5 1 Simple weighing Press the on off key or Turn on the power switch on the right side of balance 2 The balance power on with beep and backlight flash 3 Wait till the screen displays 0 009 Press ZERO key to enter weighing mode if the screen doesn t display 0 009 4 Put the object on weighing pan then read the weight within 2 3 seconds 5 2 Tare funciton 1 Put the container object on weighing pan press TARE to deduct the container object weight the screen displays 0 009 2 Put more objects on the weighing pan the screen displays weight of new objects excluding weight of container 5 3 Units shift and setting Under weighing mode press UNITS key to change to the unit you need Open more units or close any units please contact your local agent 5 4 Simple counting setting 1 Under weighing mode press PCS choose the simple counting function Put on the weights if no unit weight setting before screen will display O pcs page 4 Balance User Manual Press UNIT key enter quantity setting The screen displays
5. libration successfully Page 5 Balance User Manual 6 ERROR MESSAGE AND TROUBLESHOOTING 1 Error message Over A D resolution range Low A D resolution range Over load max capacity 9e Low battery alar Low battery Need charge 2 Trouble shooting Where Possible Error message Power on ADO Check and remove the object from weighing pan or send back for repair Battery symbol Charge the battery Normal weighing OVR Check if weighing object over the mode Capacity 9e Trouble shooting Normal weighing mode Lo bAt Charge the battery Call your agent here page 6 V 1203

Download Pdf Manuals

image

Related Search

EE20003 e200030 busy e200030 svn ee2000 interactive e2003 pass es2003 driver e2003ptl coel e2003ba lenovo e2003 pandrol clip e2003 undeclared identifier delphi e2003ws e200009 svn ea200001 es2003 e20030dl-ib elevator e2003 undeclared identifier

Related Contents

ESTUDIO DE “CARACTERIZACIÓN DEL PARQUE DE  Reed Solomon IP 自動生成ツール 取り扱い説明書 Version 1.0  Samsung GE83X User Manual(ENGLISH)  Symantec LiveState Recovery Desktop 3.0 for PC  Quick-Start Memor  TCP/IP-INT-PTX - RVR Elettronica SpA Documentation Server  User Guide  Smeg S890PMFR7  Installation von Sentinel 5 für Oracle unter Linux  