Home
USERS MANUAL EasySplicer
Contents
1. a piece of fiber Prepare the fibers Splice the fibers Analyze the splice Remove the fiber Protect the splice Connecting the splicer to power Connect the power supply if power is available Or use the internal battery Starting the splicer Start the splicer by pressing the large button until the splicer starts Fusion splicer menus The basic menu looks like this MENU Enter the menu system described below RESET Reset the alignment motors to start position SPLICE Start splicing Main menu EXIT Exit menu CLEAN ELECTRODES Run the clean program to remove dirt on electrodes This should be done at least every 20 splice CALIBRATE Start automatic environmental compensation This should be done every time the environment changes The splicer will adjust this calibration a small step every splice but when changing environment this calibration will be needed To prepare for this calibration strip and clean a piece of fiber and place it all the way through the v grove and then start the calibration The PWR value will be updated TURN OVEN ON Manually run the oven program Normally when a splice is done next step is to move the fiber with a sleeve to the oven and press the OVEN button SETUP Setup various things shown below INFO Shows miscellaneous information of the splicer Setup menu FIBER TYPES Change the fiber type to splice SET CLOCK Set the internal clock OVEN Set the oven time L
2. ANGUAGE Set menu language FIBER POSITION Change fiber position when replacing cleaver EXIT Exit menu Fiber type menu SINGLE MODE FIBER Setup splicer for splicing SMF MULTI MODE FIBER Setup splicer for splicing MMF EXIT Exit menu Set clock menu UP Changes selected items up one step DOWN Changes selected items down one step MOVE Steps to next item When Exit item is selected chose Exit button to set the new time CAL FIBER POS Starts automatic calibration of fiber zero point setting Put fibers in their holders and place them in the splicer before starting SAVE NEW POS If the fibers are visible and in the correct position like in the picture above the new position can be saved Preparing the fiber Often incorrect handling or preparation causes splice loss It is crucial to keep tools and fiber clean the invested time used in fiber and tool handling is more than compensated for in reduced troubleshooting effort Protective sleeve Before preparing the fiber for splicing make sure to put the protective sleeve in place Stripping the fiber Hold the stripping tool to the edge of the fiber holder Press the handles together and pull firmly away from the fiber holder to remove the coating Cleaning the fiber Use a pair of tweezers equipped with cotton buds soaked in alcohol according to picture or a similar tool Press the tweezers together and clean the fiber with by movin
3. USERS MANUAL EasySplicer Table of contents T tFOGUC HOD a a tutes O 3 BIS DIMISIT TOES 3 APP UCAUO Gosodon socer odo nae ea S RUE d Inn usse tua usu er M M dA A uM DHL 3 DPustomsplitcer compoblebibs co ee nde Ee octies OE ER a aa e ce tie RO in gt a e eR IN AS 4 Basics nete LU MM MUI UU 4 Order OEI dune eoe uteM e M PM I MM eR UM NEC ILLI LER Me SLIDE 4 Connect the spHcet FO DOWOLD nies visited pex tuae dete bui eias Eie Renee utut 4 Diario TDe s DIO CE amane ort n ib ep teta anc cL tuu tit bs copi e ari Casper 4 PEusionasphicet WC MUS ics peer euis estatal tad usine tus du uet eut aha seven cs I ume 4 Mie aee Mtem det tet MA Hense tu Mende teen eed coin testas Mund tes aa eosin te nana tuli aM scum 6 TEn T TT 7 Salo SB DITE Ail S b DNE Re EIEEE TE ne ne Pe TOL 7 visere ern T ccm 8 Pep Arai TAG IDE iocos celat n eestor ase se 9 ligure CS EC MM ne uaa aambate 9 DIDI LMC MIDE E ou io tt EN C EE E ME a Ra UM UM MEE 9 Cleammno die DDO oboe itbeet ae tbe oun ER utres nel E pes Ht tuse pecunie EL eR te dte Kei a niit 10 lea VAS tho TIDE act m r T E 11 vielem HEURE NETTEN 13 Cleaning the V groove of the fusion spliCet ii ies e rete IA EH EO YA RATRE TUR RS AS RE oas 16 OVEBDSIAImitt fd CC honesti iei tieni esito nr Ree eee uisa ubi RENT ee I eterna Serene Rene me 17 Technical E citate Obat mM MMC M atl LUDUM MUSS 18 Introduction The EasySplicer incorporates all the best a fixed v groove sp
4. e re spliced Cleaning the v groove of the fusion splicer The function of the high precision surface of the v groove can be influenced by dirt Whenever there is a consistent problem with fiber offset try cleaning the surface as follows To clean the v groove proceed as follows Put a fiber in a fiber holder strip clean and cleave it Use this fiber to scratch the v grove at an angle several times back and forth Then put the fiber in place like you would do a splice and check the removed dirt via the camera This procedure should be repeated until there is no dirt visible to the camera 16 Oven maintenance The oven needs to be cleaned and greased with regular intervals to make removal of the shrink sleeves easy Use silicon grease and apply it to the bottom of the oven with a cotton bud See below 17 Technical data Weight 800g Dimensions 230x98x53 mm Alignment Axial Automatic Radial Fixed v groove Fusion technique Arc fusion Process Automatic Typical Loss SMF 0 03dB MMF 0 01dB Splice Programs 2 factory defined Display 2 8 Color TFT Power source Battery 7 4V 2200mAh Built in Power supply 100 240V AC 6V DC 1 25A Operating environment Temperature 0 C to 45 C Humidity max 95 RH non condensing Storage environment Temperature 20 C to 60 C Humidity max 98 RH non condensing Heat oven Built in
5. g the tweezers from the fiber holder towards the end of the fiber Repeat but rotate the tweezers A squeaking sound indicates that the fiber is clean 10 Cleaving the fiber Position the fiber holder in the cleaver Insert the fiber holder from above not from the side Move the sliding part of the cleaver towards you 11 Close the cleaver lid and push the sliding part away from you Lift the fiber holder up so that it don t get dirty 12 Splicing Select the proper splice program Make sure a reset has been performed since last splice Place the fiber holder Keep the fiber holder at an angle and move it passed its intended resting place Fold the fiber holder down until it makes contact with support surface Gently pull the fiber holder back until it snaps in place Repeat for the other fiber holder Lower the fiber pressure foot slowly and lock the fibers in position Close the lid The fiber should now be visible in the monitor like below Are the fibers clean GOOD VERY BAD If not re do the stripping cleaning and cleaving procedure Are the fibers properly aligned BAD If not make sure the fiber holders are properly snapped into place If this does not help clean the v groove described below Press the SPLICE button When the fully automated splicing process is done the estimated loss is presented If estimated loss is bigger than 0 1dB the splice is bad and has to b
6. licer can offer NOTE EasySplicer is a high precision instrument and should always be handled with care Disclaimer SB Scandinavia AB reserves the right to modify the product in any way without prior customer notification or any other form of notice In no event shall SB Scandinavia AB be liable for any damages of any type incidental indirect consequential or other originating from or relating to this manual or the information contained herein While SB Scandinavia AB tries to make the user manual complete and accurate it may contain mistakes and the user uses it solely at his or her own risk Application Splicing and protection of most common types of SMF and MMF Fusion splicer components The following components are included and standard for splicing in the field Item Description Quantity 1 EasySplicer 1 2 Power supply 1 3 Fiber cleaver 1 4 Fiber holders 250um 1p 5 Fiber holders 900um 1 pair 6 Stripper 1 T Carrying bag 1 8 Users manual on CD 1 Basics NOTE The EasySplicer is a rugged field instrument designed to withstand field environment However to ensure best performance it is important to keep maintenance as described later in this manual Order of operation If available connect the splicer to a power source Please watch the attached videos to learn how to operate the EasySplicer in a fast and easy way Turn on the splicer Select proper splice program Run calibrate process with
Download Pdf Manuals
Related Search
Related Contents
livro melhor do que comprar sapatos Rand McNally RVND 5525 LM User's Manual Copyright © All rights reserved.
Failed to retrieve file